Joon-Ho Kim, Byoung-Gyun Kim, E. Yoon, Chul‐Hi Han
{"title":"用于血液分析的新型单片微型生物传感器","authors":"Joon-Ho Kim, Byoung-Gyun Kim, E. Yoon, Chul‐Hi Han","doi":"10.1109/MEMSYS.2001.906573","DOIUrl":null,"url":null,"abstract":"A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm/sup 2/.mM for detecting glucose levels in a wide linear range of 0/spl sim/50 mM in potassium phosphate buffer solution (pH7.0).","PeriodicalId":311365,"journal":{"name":"Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090)","volume":"225 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"A new monolithic micro biosensor for blood analysis\",\"authors\":\"Joon-Ho Kim, Byoung-Gyun Kim, E. Yoon, Chul‐Hi Han\",\"doi\":\"10.1109/MEMSYS.2001.906573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm/sup 2/.mM for detecting glucose levels in a wide linear range of 0/spl sim/50 mM in potassium phosphate buffer solution (pH7.0).\",\"PeriodicalId\":311365,\"journal\":{\"name\":\"Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090)\",\"volume\":\"225 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.2001.906573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2001.906573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new monolithic micro biosensor for blood analysis
A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm/sup 2/.mM for detecting glucose levels in a wide linear range of 0/spl sim/50 mM in potassium phosphate buffer solution (pH7.0).