首页 > 最新文献

Laser Therapy最新文献

英文 中文
A PCR based study to evaluate the effectiveness of photodynamic therapy in extraction socket disinfection 基于 PCR 的研究,评估光动力疗法在拔牙窝消毒中的有效性
Pub Date : 2024-07-03 DOI: 10.4081/ltj.2024.394
Sakshi K. Nerkar, Rashmi Hedge, Nida Shaikh, Neha Langade
The purpose of this study was to assess the efficacy of (Light-Activated) Photodynamic therapy in extraction socket disinfection. The goal is to assess the quantitative and qualitative changes in microbial load following the use of photodynamic therapy in extraction socket disinfection. This study included 20 patients ranging in age from 18 to 55 years who required extraction of non-restorable teeth or those with periapical lesions. Extraction was done under local anesthesia, following the principles of atraumatic extraction for socket preservation. Pre-operative samples were collected with paper points for real-time polymerase chain reaction (PCR) analysis. A photosensitizer, Methylene blue dye, was applied for 60 seconds. The PDT laser (660nm) was used for a total of 3 minutes, with 20 second intervals. Following PDT application, repeat samples were collected for PCR analysis to determine the bactericidal effect in socket disinfection. The results showed a predominance of P. gingivalis, a potential periodontal pathogen, and a significant reduction in the same following the application of light activated PDT. Photodynamic therapy has demonstrated promising bactericidal effects, which can improve postoperative outcomes and be considered as one treatment option for immediate implants in infected sockets.
本研究的目的是评估(光激活)光动力疗法在拔牙窝消毒中的疗效。目的是评估在拔牙窝消毒中使用光动力疗法后微生物负荷的定量和定性变化。这项研究包括 20 名年龄在 18 至 55 岁之间的患者,他们都需要拔除无法修复的牙齿或根尖周病变的牙齿。拔牙是在局部麻醉下进行的,遵循无创伤拔牙以保留牙槽窝的原则。术前用纸点采集样本,进行实时聚合酶链反应(PCR)分析。使用光敏剂(亚甲蓝染料)60 秒。PDT 激光(660 纳米)共使用 3 分钟,间隔 20 秒。使用 PDT 后,重复采集样本进行 PCR 分析,以确定牙槽窝消毒的杀菌效果。结果显示,潜在的牙周致病菌牙龈脓疱疮杆菌占多数,而在使用光动力疗法后,牙龈脓疱疮杆菌明显减少。光动力疗法具有良好的杀菌效果,可以改善术后效果,可作为感染性牙槽窝即刻种植的一种治疗方案。
{"title":"A PCR based study to evaluate the effectiveness of photodynamic therapy in extraction socket disinfection","authors":"Sakshi K. Nerkar, Rashmi Hedge, Nida Shaikh, Neha Langade","doi":"10.4081/ltj.2024.394","DOIUrl":"https://doi.org/10.4081/ltj.2024.394","url":null,"abstract":"The purpose of this study was to assess the efficacy of (Light-Activated) Photodynamic therapy in extraction socket disinfection. The goal is to assess the quantitative and qualitative changes in microbial load following the use of photodynamic therapy in extraction socket disinfection. This study included 20 patients ranging in age from 18 to 55 years who required extraction of non-restorable teeth or those with periapical lesions. Extraction was done under local anesthesia, following the principles of atraumatic extraction for socket preservation. Pre-operative samples were collected with paper points for real-time polymerase chain reaction (PCR) analysis. A photosensitizer, Methylene blue dye, was applied for 60 seconds. The PDT laser (660nm) was used for a total of 3 minutes, with 20 second intervals. Following PDT application, repeat samples were collected for PCR analysis to determine the bactericidal effect in socket disinfection. The results showed a predominance of P. gingivalis, a potential periodontal pathogen, and a significant reduction in the same following the application of light activated PDT. Photodynamic therapy has demonstrated promising bactericidal effects, which can improve postoperative outcomes and be considered as one treatment option for immediate implants in infected sockets.","PeriodicalId":507900,"journal":{"name":"Laser Therapy","volume":"92 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141682739","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Keratorefractive lenticule extraction in eyes with post-herpetic scars 带疱疹后疤痕眼睛的角膜屈光透镜摘除术
Pub Date : 2024-07-01 DOI: 10.4081/ltj.2024.397
Antonio Leccisotti, Stefania V. Fields, G. De Bartolo, Christian Crudale, Matteo Posarelli
Correcting refractive errors by remodeling the corneal curvature with an excimer laser (which emits ultraviolet radiation) may reactivate a latent Herpes Simplex Virus (HSV), resulting in keratitis. New techniques using infrared sources, such as femtosecond-assisted Keratorefractive Lenticule Extraction (KLEx), may thus provide a safer approach to eyes with previous HSV keratitis; however, no cases of KLEx in such cases have been reported. As a result, we present three cases in which KLEx successfully corrected myopia. Three myopic eyes from three patients with a known history of healed HSV keratitis that occurred more than 12 months before surgery underwent KLEx. All patients received oral antiviral prophylaxis before and after surgery. In case 1, the post-HSV scar was semiperipheral, involving only a portion of the treated area; surgery went smoothly, with the intrastromal lenticule well delineated and dissected even through the scar. In cases 2 and 3, the healed scar was peripheral and did not interfere with surgery. After 6 months, all three cases had good visual acuity without complications. Finally, KLEx combined with antiviral prophylaxis can effectively correct myopia in eyes with healed HSV. The femtosecond laser can penetrate non-dense, peripheral corneal scars.
用准分子激光(发射紫外线)重塑角膜曲率来矫正屈光不正,可能会重新激活潜伏的单纯疱疹病毒(HSV),导致角膜炎。因此,使用红外线光源的新技术,如飞秒辅助角膜屈光性皮瓣摘除术(KLEx),可能会为曾患有 HSV 角膜炎的眼睛提供更安全的治疗方法;但目前还没有关于此类病例的 KLEx 案例报道。因此,我们介绍了三例 KLEx 成功矫正近视的病例。来自三位患者的三只近视眼接受了 KLEx 手术,这三位患者都曾在手术前 12 个月以上患过痊愈的 HSV 角膜炎。所有患者在手术前后都接受了口服抗病毒预防治疗。在病例 1 中,HSV 后疤痕是半周性的,只涉及治疗区域的一部分;手术进行得很顺利,即使穿过疤痕也能很好地划定和剥离基质内皮孔。在病例 2 和病例 3 中,愈合的疤痕位于周围,不影响手术。6 个月后,这三个病例的视力都很好,没有出现并发症。最后,KLEx 结合抗病毒预防措施可以有效矫正HSV痊愈患者的近视。飞秒激光可以穿透非致密的周边角膜疤痕。
{"title":"Keratorefractive lenticule extraction in eyes with post-herpetic scars","authors":"Antonio Leccisotti, Stefania V. Fields, G. De Bartolo, Christian Crudale, Matteo Posarelli","doi":"10.4081/ltj.2024.397","DOIUrl":"https://doi.org/10.4081/ltj.2024.397","url":null,"abstract":"Correcting refractive errors by remodeling the corneal curvature with an excimer laser (which emits ultraviolet radiation) may reactivate a latent Herpes Simplex Virus (HSV), resulting in keratitis. New techniques using infrared sources, such as femtosecond-assisted Keratorefractive Lenticule Extraction (KLEx), may thus provide a safer approach to eyes with previous HSV keratitis; however, no cases of KLEx in such cases have been reported. As a result, we present three cases in which KLEx successfully corrected myopia. Three myopic eyes from three patients with a known history of healed HSV keratitis that occurred more than 12 months before surgery underwent KLEx. All patients received oral antiviral prophylaxis before and after surgery. In case 1, the post-HSV scar was semiperipheral, involving only a portion of the treated area; surgery went smoothly, with the intrastromal lenticule well delineated and dissected even through the scar. In cases 2 and 3, the healed scar was peripheral and did not interfere with surgery. After 6 months, all three cases had good visual acuity without complications. Finally, KLEx combined with antiviral prophylaxis can effectively correct myopia in eyes with healed HSV. The femtosecond laser can penetrate non-dense, peripheral corneal scars.","PeriodicalId":507900,"journal":{"name":"Laser Therapy","volume":"345 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141691624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of laser-activated bleaching with 445, 915, and 970nm diode lasers on enamel color change: an in vitro study 445、915 和 970 纳米二极管激光器激活的激光漂白对珐琅质颜色变化的影响:体外研究
Pub Date : 2024-06-13 DOI: 10.4081/ltj.2024.391
S. Shahabi, Alireza Tabatabaeian, Luca Solimei, Stefano Benedicenti, S. Saberi
  Considering the increasing use of esthetic treatments, one of which is bleaching treatment, choosing the different wavelengths and parameters for this treatment can help in choosing the best treatment. Based on this, this study aimed to investigate bleaching with three wavelengths of 445nm, 915nm, and 970 nm on the amount of teeth discoloration. In this study, 77 human permanent teeth without caries were selected and randomly divided into 7 groups as control, 445 nm (1 and 1.5 W and time 20 seconds), 915 nm (2 and 2.5 W and time 30 seconds) and 970 nm (1.5 and 2 W and time 30 seconds). The bleaching gel used was 40% hydrogen peroxide bleaching gel(Ultradent-Opalescence, USA). All groups were subjected to laser irradiation with a 0.5 cm2 area with continuous wave mode radiation at a distance of 1 mm from the bleaching gel. Before starting the study, all the samples were subjected to calorimetry using a spectrophotometer. After bleaching with the said wavelengths, Color change data on the CIE L * a * b* system was analyzed statistically by the one-way ANOVA and Tukey’s HSD test. Based on the findings, ΔE was positive in all groups. The highest amount was in the 445nm 1.5w group and the lowest was seen in the control group and then in the 970nm 2w group (P<0.05). The highest dispersion of color change is related to the 445nm 1.5w group (P<0.05). In general, the results showed that the use of 445nm diode laser 1.5w (ΔE=12) and 970nm diode laser 2w (ΔE=37.5) was the most and least effective in teeth bleaching, respectively. According to the results of the present Invitro study, the 445 nm laser with a power of 1.5 watts had the most effect in changing tooth color, and the 970 nm group with a power of 2 watts showed the least effect. 
考虑到美容治疗的使用越来越多,漂白治疗就是其中之一,选择不同的波长和参数有助于选择最佳的治疗方法。基于此,本研究旨在探讨 445 纳米、915 纳米和 970 纳米三种波长的漂白对牙齿变色量的影响。本研究选取了 77 颗无龋齿的人类恒牙,随机分为 7 组,分别为对照组、445 纳米组(1 瓦和 1.5 瓦,时间 20 秒)、915 纳米组(2 瓦和 2.5 瓦,时间 30 秒)和 970 纳米组(1.5 瓦和 2 瓦,时间 30 秒)。使用的漂白凝胶为 40% 过氧化氢漂白凝胶(Ultradent-Opalescence,美国)。所有实验组均在距离漂白凝胶 1 毫米处接受 0.5 平方厘米面积的连续波模式激光照射。研究开始前,所有样品都用分光光度计进行了热量测定。使用上述波长漂白后,通过单因素方差分析和 Tukey's HSD 检验,对 CIE L * a * b* 系统的颜色变化数据进行了统计分析。结果显示,ΔE 在所有组别中均呈阳性。445nm 1.5w 组的ΔE 值最高,对照组最低,然后是 970nm 2w 组(P<0.05)。颜色变化分散度最高的是 445nm 1.5w 组(P<0.05)。总之,结果表明,使用 445nm 二极管激光器 1.5w (ΔE=12)和 970nm 二极管激光器 2w (ΔE=37.5)对牙齿漂白的效果分别最好和最差。根据本次无创研究的结果,功率为 1.5 瓦的 445 纳米激光对改变牙齿颜色的效果最好,而功率为 2 瓦的 970 纳米激光组的效果最差。
{"title":"Effect of laser-activated bleaching with 445, 915, and 970nm diode lasers on enamel color change: an in vitro study","authors":"S. Shahabi, Alireza Tabatabaeian, Luca Solimei, Stefano Benedicenti, S. Saberi","doi":"10.4081/ltj.2024.391","DOIUrl":"https://doi.org/10.4081/ltj.2024.391","url":null,"abstract":" \u0000 Considering the increasing use of esthetic treatments, one of which is bleaching treatment, choosing the different wavelengths and parameters for this treatment can help in choosing the best treatment. Based on this, this study aimed to investigate bleaching with three wavelengths of 445nm, 915nm, and 970 nm on the amount of teeth discoloration. In this study, 77 human permanent teeth without caries were selected and randomly divided into 7 groups as control, 445 nm (1 and 1.5 W and time 20 seconds), 915 nm (2 and 2.5 W and time 30 seconds) and 970 nm (1.5 and 2 W and time 30 seconds). The bleaching gel used was 40% hydrogen peroxide bleaching gel(Ultradent-Opalescence, USA). All groups were subjected to laser irradiation with a 0.5 cm2 area with continuous wave mode radiation at a distance of 1 mm from the bleaching gel. Before starting the study, all the samples were subjected to calorimetry using a spectrophotometer. After bleaching with the said wavelengths, Color change data on the CIE L * a * b* system was analyzed statistically by the one-way ANOVA and Tukey’s HSD test. Based on the findings, ΔE was positive in all groups. The highest amount was in the 445nm 1.5w group and the lowest was seen in the control group and then in the 970nm 2w group (P<0.05). The highest dispersion of color change is related to the 445nm 1.5w group (P<0.05). In general, the results showed that the use of 445nm diode laser 1.5w (ΔE=12) and 970nm diode laser 2w (ΔE=37.5) was the most and least effective in teeth bleaching, respectively. According to the results of the present Invitro study, the 445 nm laser with a power of 1.5 watts had the most effect in changing tooth color, and the 970 nm group with a power of 2 watts showed the least effect. ","PeriodicalId":507900,"journal":{"name":"Laser Therapy","volume":"18 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141347591","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Laser Therapy
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1