首页 > 最新文献

Journal of The British Contact Lens Association最新文献

英文 中文
BCLA news 巴塞尔公约图书馆协会新闻
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80017-4
{"title":"BCLA news","authors":"","doi":"10.1016/S0141-7037(95)80017-4","DOIUrl":"https://doi.org/10.1016/S0141-7037(95)80017-4","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 3","pages":"Page 105"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80017-4","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137286486","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Incidence of ulcers in conventional and disposable soft contact lenses 常规和一次性软性隐形眼镜的溃疡发生率
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80046-8
Fiona Stapleton, John Dart, Cherry Radford, Darwin Minassian
{"title":"Incidence of ulcers in conventional and disposable soft contact lenses","authors":"Fiona Stapleton, John Dart, Cherry Radford, Darwin Minassian","doi":"10.1016/S0141-7037(95)80046-8","DOIUrl":"10.1016/S0141-7037(95)80046-8","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 1","pages":"Pages 29-30"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80046-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75803791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Contact lens diary 隐形眼镜日记
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80037-9
{"title":"Contact lens diary","authors":"","doi":"10.1016/S0141-7037(95)80037-9","DOIUrl":"https://doi.org/10.1016/S0141-7037(95)80037-9","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 2","pages":"Page 77"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80037-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"92123909","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical performance of a daily disposable contact lens: a 3-month prospective study 每日一次性隐形眼镜的临床表现:一项为期3个月的前瞻性研究
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80012-3
MD, PhD Sven Erik G. Nilsson , Monica Söderqvist

Thirty-one myopic patients, 20 of whom were experienced contact lens wearers, were fitted with 1-Day Acuvue lenses, −253(±0.18) dioptres (D) on average, at initial dispensing. These lenses are inserted in the morning and disposed of every night. After an initial examination, the patients were followed up after 1 week and 12 weeks of lens wear. Visual acuity was 1.25(±0.02) on average, at the 12-week follow-up, significantly (P <0.005) better with the 1-Day Acuvue lenses than with the patients' previous lenses. Subjectively reported symptoms decreased significantly (P <0.02) after the patients' previous lenses were replaced with the 1-Day Acuvue lenses (20 patients); dryness/burning decreased from 35% to 5% (P <0.001). Slit-lamp findings also decreased significantly (P<0.001), injection from 23% to 0% and tarsal abnormalities from 20% to 0% (20 patients). There were no true complications. All 20 experienced lens wearers had deposit problems before the study, but these disappeared with the 1-Day lenses. When the experienced wearers compared their former lenses with their new 1 -Day Acuvue lenses, the latter were judged significantly (P <0.01–0.001) better regarding comfort and vision, equal regarding determination of lens orientation and worse (P <0.01) regarding lens handling. Overall satisfaction — a general assessment — favoured the 1-Day lenses at a highly significant (P <0.001) level, however. Thus, the 1-Day Acuvue concept appears very attractive with regard to complication rate as well as performance.

31名近视患者,其中20名是经验丰富的隐形眼镜配戴者,在首次配药时配戴1天Acuvue隐形眼镜,平均−253(±0.18)屈光度(D)。这些镜片在早上插入,每天晚上处理掉。初步检查后,分别于配戴1周和12周后进行随访。随访12周时,患者的平均视力为1.25(±0.02),1 d Acuvue隐形眼镜明显优于既往隐形眼镜(P <0.005)。20例患者使用1-Day Acuvue隐形眼镜后,主观报告的症状明显减轻(P <0.02);干燥/灼烧从35%下降到5% (P <0.001)。裂隙灯的发现也显著减少(P<0.001),注射从23%减少到0%,跗骨异常从20%减少到0%(20例)。没有真正的并发症。所有20名有经验的隐形眼镜佩戴者在研究前都有沉积问题,但这些问题在1天的隐形眼镜后消失了。当有经验的佩戴者将他们的旧镜片与新的1天Acuvue镜片进行比较时,后者在舒适度和视力方面被认为明显更好(P <0.01 - 0.001),在确定镜片方向方面被认为相同,在镜片处理方面被认为更差(P <0.01)。然而,总体满意度-一般评估-在高度显著(P <0.001)水平上支持1天镜片。因此,1天Acuvue的概念在并发症发生率和性能方面显得非常有吸引力。
{"title":"Clinical performance of a daily disposable contact lens: a 3-month prospective study","authors":"MD, PhD Sven Erik G. Nilsson ,&nbsp;Monica Söderqvist","doi":"10.1016/S0141-7037(95)80012-3","DOIUrl":"10.1016/S0141-7037(95)80012-3","url":null,"abstract":"<div><p>Thirty-one myopic patients, 20 of whom were experienced contact lens wearers, were fitted with 1-Day Acuvue lenses, −253(±0.18) dioptres (D) on average, at initial dispensing. These lenses are inserted in the morning and disposed of every night. After an initial examination, the patients were followed up after 1 week and 12 weeks of lens wear. Visual acuity was 1.25(±0.02) on average, at the 12-week follow-up, significantly (<em>P</em> &lt;0.005) better with the 1-Day Acuvue lenses than with the patients' previous lenses. Subjectively reported symptoms decreased significantly (<em>P</em> &lt;0.02) after the patients' previous lenses were replaced with the 1-Day Acuvue lenses (20 patients); dryness/burning decreased from 35% to 5% (<em>P</em> &lt;0.001). Slit-lamp findings also decreased significantly (<em>P</em>&lt;0.001), injection from 23% to 0% and tarsal abnormalities from 20% to 0% (20 patients). There were no true complications. All 20 experienced lens wearers had deposit problems before the study, but these disappeared with the 1-Day lenses. When the experienced wearers compared their former lenses with their new 1 -Day Acuvue lenses, the latter were judged significantly (<em>P</em> &lt;0.01–0.001) better regarding comfort and vision, equal regarding determination of lens orientation and worse (<em>P</em> &lt;0.01) regarding lens handling. Overall satisfaction — a general assessment — favoured the 1-Day lenses at a highly significant (<em>P</em> &lt;0.001) level, however. Thus, the 1-Day Acuvue concept appears very attractive with regard to complication rate as well as performance.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 3","pages":"Pages 81-86"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80012-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82733911","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Contact lens diary 隐形眼镜日记
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80049-2
{"title":"Contact lens diary","authors":"","doi":"10.1016/S0141-7037(95)80049-2","DOIUrl":"https://doi.org/10.1016/S0141-7037(95)80049-2","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 1","pages":"Page 33"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80049-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136594881","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A technique for measuring the alternating current electrical conductivity of hydrogels 测量水凝胶交流电导电性的一种技术
Pub Date : 1995-01-01 DOI: 10.1016/S0141-7037(95)80022-0
BSc, GrandInstP, FBDO(Hons)Cl, (Hons)SLD David T.R. Austin, DPhil, MInstP, CPhys. David C. Champeney

A technique for measuring the electrical conductivity of hydrogels (range of water contents 38–75%) is described using samples in button form, the aim being to discover the correlations that exist between conductivity and other measurable variables such as water content and oxygen permeability. The technique overcomes the problem of electrode interface impedance by analysing impedance values over a range of frequencies, and the design of the conductivity cell allows effects of compression to be studied. Results so far indicate that reproducible conductivity values are obtained, that the conductivity rises, at an increasing rate, with increase in water content and that there is a correlation between electrical conductivity and permeability.

一种测量水凝胶电导率的技术(水含量范围38-75%)描述了使用按钮形式的样品,目的是发现电导率与其他可测量变量(如含水量和氧渗透率)之间存在的相关性。该技术通过分析频率范围内的阻抗值来克服电极界面阻抗的问题,并且电导率电池的设计允许研究压缩的影响。到目前为止的结果表明,获得了可重复的电导率值,电导率随着含水量的增加而增加,并且电导率与渗透率之间存在相关性。
{"title":"A technique for measuring the alternating current electrical conductivity of hydrogels","authors":"BSc, GrandInstP, FBDO(Hons)Cl, (Hons)SLD David T.R. Austin,&nbsp;DPhil, MInstP, CPhys. David C. Champeney","doi":"10.1016/S0141-7037(95)80022-0","DOIUrl":"10.1016/S0141-7037(95)80022-0","url":null,"abstract":"<div><p>A technique for measuring the electrical conductivity of hydrogels (range of water contents 38–75%) is described using samples in button form, the aim being to discover the correlations that exist between conductivity and other measurable variables such as water content and oxygen permeability. The technique overcomes the problem of electrode interface impedance by analysing impedance values over a range of frequencies, and the design of the conductivity cell allows effects of compression to be studied. Results so far indicate that reproducible conductivity values are obtained, that the conductivity rises, at an increasing rate, with increase in water content and that there is a correlation between electrical conductivity and permeability.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 4","pages":"Pages 115-118"},"PeriodicalIF":0.0,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80022-0","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89547468","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Creating a good impression 给人留下好印象
Pub Date : 1994-01-01 DOI: 10.1016/S0141-7037(94)80002-2
Nigel F. Burnett Hodd
{"title":"Creating a good impression","authors":"Nigel F. Burnett Hodd","doi":"10.1016/S0141-7037(94)80002-2","DOIUrl":"10.1016/S0141-7037(94)80002-2","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"17 2","pages":"Pages 37-42"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(94)80002-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85430607","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Toric periphery rigid lenses 环面外围刚性透镜
Pub Date : 1994-01-01 DOI: 10.1016/S0141-7037(94)80020-0
BSc, FBCO, DCLP Keith Edwards , BA Tony Hough

Lenses with toric peripheries and spherical optic zones have been advocated to improve the fit of rigid lenses on corneas with moderate astigmatism. However there is usually little discussion of the theoretical background to this fitting technique. A review of the manufacturing process permits the development of a model which will allow the computation of those optic zone data that are dependent on other specified lens parameters. These data then enable tear layer profiling to predict improvements in fit for specific lens designs and corneal models. Results from such calculations indicate that many lenses cannot be manufactured precisely as ordered and this could result in variability in specification and performance. The physical fit of tonic periphery lenses can be shown to be optimal when the selected parameters produce a monocurve back surface along the steep meridian. This is confirmed when fitting lenses in a clinical environment.

为了改善中度散光角膜的配准性,建议采用环形外周和球形光学带的晶状体。然而,通常很少讨论这种拟合技术的理论背景。对制造过程的回顾允许开发一个模型,该模型将允许计算依赖于其他指定透镜参数的光学区数据。这些数据使泪液层分析能够预测适合特定晶状体设计和角膜模型的改进。这样的计算结果表明,许多透镜不能精确地按照订购制造,这可能导致规格和性能的变化。当所选参数沿陡直子午线产生单曲线后表面时,强直外围透镜的物理拟合最佳。这在临床配戴镜片时得到证实。
{"title":"Toric periphery rigid lenses","authors":"BSc, FBCO, DCLP Keith Edwards ,&nbsp;BA Tony Hough","doi":"10.1016/S0141-7037(94)80020-0","DOIUrl":"10.1016/S0141-7037(94)80020-0","url":null,"abstract":"<div><p>Lenses with toric peripheries and spherical optic zones have been advocated to improve the fit of rigid lenses on corneas with moderate astigmatism. However there is usually little discussion of the theoretical background to this fitting technique. A review of the manufacturing process permits the development of a model which will allow the computation of those optic zone data that are dependent on other specified lens parameters. These data then enable tear layer profiling to predict improvements in fit for specific lens designs and corneal models. Results from such calculations indicate that many lenses cannot be manufactured precisely as ordered and this could result in variability in specification and performance. The physical fit of tonic periphery lenses can be shown to be optimal when the selected parameters produce a monocurve back surface along the steep meridian. This is confirmed when fitting lenses in a clinical environment.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"17 4","pages":"Pages 107-114"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(94)80020-0","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77989065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Viability of disposable soft contact lenses for themonovision correction of presbyopia 一次性软性隐形眼镜用于老花眼单视矫正的可行性
Pub Date : 1994-01-01 DOI: 10.1016/S0141-7037(94)80033-2
BSc (Hons), MSc, PhD, FBCO Christine Ramsdale, PhD, MBCO, FVCO, FAAO Nathan Efron

Every presbyopic patient (n = 257) attending for routine examination at a suburban optometric practice was offeredthe opportunity to wear disposable contact lenses in the form of monovision correction. Sixty subjects entered the 3-month study. Only 5% of the total number of presbyopis who attended initially, were prepared to continue as fee paying contact lens wearers. As has been found in other studies, monovision correction itself did not cause any significant visual problems (90% acceptance). It is concluded that disposable soft lenses for monovision correction of presbyopia is a viable economical alternative for a small number of selected patients.

每个在郊区验光诊所接受常规检查的老花眼患者(n = 257)都有机会佩戴一次性单视矫正隐形眼镜。60名受试者参加了为期3个月的研究。只有5%的老花眼患者准备继续付费佩戴隐形眼镜。正如在其他研究中发现的那样,单视矫正本身不会引起任何明显的视觉问题(90%的接受度)。结论:一次性软性晶状体用于老花眼单视矫正是一种经济可行的选择。
{"title":"Viability of disposable soft contact lenses for themonovision correction of presbyopia","authors":"BSc (Hons), MSc, PhD, FBCO Christine Ramsdale,&nbsp;PhD, MBCO, FVCO, FAAO Nathan Efron","doi":"10.1016/S0141-7037(94)80033-2","DOIUrl":"10.1016/S0141-7037(94)80033-2","url":null,"abstract":"<div><p>Every presbyopic patient (<em>n</em> = 257) attending for routine examination at a suburban optometric practice was offeredthe opportunity to wear disposable contact lenses in the form of monovision correction. Sixty subjects entered the 3-month study. Only 5% of the total number of presbyopis who attended initially, were prepared to continue as fee paying contact lens wearers. As has been found in other studies, monovision correction itself did not cause any significant visual problems (90% acceptance). It is concluded that disposable soft lenses for monovision correction of presbyopia is a viable economical alternative for a small number of selected patients.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"17 3","pages":"Pages 91-96"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(94)80033-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89111246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Contact lens diary 隐形眼镜日记
Pub Date : 1994-01-01 DOI: 10.1016/S0141-7037(94)80008-1
{"title":"Contact lens diary","authors":"","doi":"10.1016/S0141-7037(94)80008-1","DOIUrl":"https://doi.org/10.1016/S0141-7037(94)80008-1","url":null,"abstract":"","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"17 2","pages":"Page 65"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(94)80008-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137437571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Journal of The British Contact Lens Association
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1