首页 > 最新文献

Electromyography and clinical neurophysiology最新文献

英文 中文
Hearing evaluation of school children in Kuwait. 科威特学童听力评估。
J M Al-Kandari, W B Alshuaib

Purpose: Hearing level in some children may be abnormal due to conductive or sensorineural causes. In Kuwait, the hearing screening test is not conducted for newborns at public hospitals. We evaluated the hearing level of 159 Kuwaiti school children (age 6-12 years) at the Audiology Clinic of Ahmadi hospital to determine the extent and causes of hearing loss in these children.

Methods: Each child was evaluated by otoscopic examination, tympanogram, acoustic reflex threshold (ART), audiogram, and distortion product oto-acoustic emission (DPOAE).

Results: 120 children were found to have normal ear conditions, while 39 children had abnormal results. The abnormalities were 21 children with ear wax, 16 children with secretory otitis media (SOM), and 2 children with sensorineural hearing loss (SNHL). In the children with ear wax, 3 had normal hearing level, while 18 had mild conductive hearing loss in the 250-500 Hz frequency range. In the children with SOM, 3 had normal hearing level, 9 had mild conductive hearing loss in the 250-500 Hz frequency range, while 4 had moderate conductive hearing loss in the 250-2000 Hz frequency range. The children with SNHL had moderate hearing loss in the 4000-8000 Hz frequency range.

Conclusion: Wax in the ear canal and SOM were the main factors associated with hearing loss in these Kuwaiti school children. It is necessary to establish a national program of school entry hearing screening in Kuwait.

目的:某些儿童的听力水平可能由于传导性或感觉神经性原因而异常。在科威特,公立医院不对新生儿进行听力筛查测试。我们在Ahmadi医院听力学诊所评估了159名科威特学龄儿童(6-12岁)的听力水平,以确定这些儿童听力损失的程度和原因。方法:采用耳镜检查、鼓室图、声反射阈值(ART)、听力图、畸变产物耳声发射(DPOAE)对患儿进行评价。结果:120例患儿耳部正常,39例患儿耳部异常。其中耳垢患儿21例,分泌性中耳炎患儿16例,感音神经性听力损失患儿2例。耳垢患儿中3例听力正常,18例在250 ~ 500 Hz频率范围内有轻度传导性听力损失。在SOM患儿中,3例听力正常,9例在250 ~ 500 Hz频率范围内有轻度传导性听力损失,4例在250 ~ 2000 Hz频率范围内有中度传导性听力损失。SNHL患儿在4000 ~ 8000hz频率范围内有中度听力损失。结论:耳垢和SOM是导致科威特学龄儿童听力损失的主要因素。有必要在科威特建立一个入学听力筛查的国家计划。
{"title":"Hearing evaluation of school children in Kuwait.","authors":"J M Al-Kandari,&nbsp;W B Alshuaib","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Hearing level in some children may be abnormal due to conductive or sensorineural causes. In Kuwait, the hearing screening test is not conducted for newborns at public hospitals. We evaluated the hearing level of 159 Kuwaiti school children (age 6-12 years) at the Audiology Clinic of Ahmadi hospital to determine the extent and causes of hearing loss in these children.</p><p><strong>Methods: </strong>Each child was evaluated by otoscopic examination, tympanogram, acoustic reflex threshold (ART), audiogram, and distortion product oto-acoustic emission (DPOAE).</p><p><strong>Results: </strong>120 children were found to have normal ear conditions, while 39 children had abnormal results. The abnormalities were 21 children with ear wax, 16 children with secretory otitis media (SOM), and 2 children with sensorineural hearing loss (SNHL). In the children with ear wax, 3 had normal hearing level, while 18 had mild conductive hearing loss in the 250-500 Hz frequency range. In the children with SOM, 3 had normal hearing level, 9 had mild conductive hearing loss in the 250-500 Hz frequency range, while 4 had moderate conductive hearing loss in the 250-2000 Hz frequency range. The children with SNHL had moderate hearing loss in the 4000-8000 Hz frequency range.</p><p><strong>Conclusion: </strong>Wax in the ear canal and SOM were the main factors associated with hearing loss in these Kuwaiti school children. It is necessary to establish a national program of school entry hearing screening in Kuwait.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 6","pages":"309-18"},"PeriodicalIF":0.0,"publicationDate":"2010-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29456284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Activation pattern masticatory muscles in dysphonics woman. 发音障碍女性咀嚼肌的激活模式。
D Rodrigues-Bigaton, A Schwarzenbeck, K C S Berni, R R J Guirro, K C A Silvério

Purpose: To evaluate the pattern of activation of the masticatory muscles in dysphonic women.

Methods: Seventeen women was divided into two groups: experimental group with 10 dysphonic women (33.6 +/- 8.0) and control group with 7 healthy women (25 +/- 5,19). The Electromyography exam of the left (LM) and right (RM) masseter muscles, anterior portion of the right (RT) and left (LT) temporal, and suprahyoid (SH) was performed by using electrodes of simple distinguishing surface.

Results: With the mandible postural position at rest, all the muscles presented increased electromyography activity compared to the control group (p < 0.05). As for the mandible elevator muscles, the RM experimental group presented significantly decreased electromyography activity (p < 0, 05) and the SH increased (p < 0.05) compared to the control group. For the rest of the muscles, there was no significantly difference between the groups. It was verified that the experimental group presented higher co-contraction of the mandible depressed muscles in relation to contraction of the RT LT, RM and LM, as compared to the control group (p < 0.05).

Conclusions: Dysphonic women present alteration of the activation patterns of the masticatory muscles.

目的:探讨发音障碍女性咀嚼肌的激活模式。方法:17例女性分为两组,实验组10例(33.6 +/- 8.0),对照组7例(25 +/- 5,19)。采用简单区分面电极对左(LM)和右(RM)咬肌、右(RT)和左(LT)颞前部、舌骨上(SH)进行肌电图检查。结果:下颌骨体位静止时,各肌肉肌电活动均较对照组增加(p < 0.05)。对于下颌骨提升肌,RM实验组肌电活动显著低于对照组(p < 0.05), SH显著高于对照组(p < 0.05)。对于其余的肌肉,两组之间没有显著差异。结果表明,实验组下颌骨下陷肌的共收缩高于对照组(p < 0.05)。结论:发音障碍女性咀嚼肌的激活模式发生改变。
{"title":"Activation pattern masticatory muscles in dysphonics woman.","authors":"D Rodrigues-Bigaton,&nbsp;A Schwarzenbeck,&nbsp;K C S Berni,&nbsp;R R J Guirro,&nbsp;K C A Silvério","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the pattern of activation of the masticatory muscles in dysphonic women.</p><p><strong>Methods: </strong>Seventeen women was divided into two groups: experimental group with 10 dysphonic women (33.6 +/- 8.0) and control group with 7 healthy women (25 +/- 5,19). The Electromyography exam of the left (LM) and right (RM) masseter muscles, anterior portion of the right (RT) and left (LT) temporal, and suprahyoid (SH) was performed by using electrodes of simple distinguishing surface.</p><p><strong>Results: </strong>With the mandible postural position at rest, all the muscles presented increased electromyography activity compared to the control group (p < 0.05). As for the mandible elevator muscles, the RM experimental group presented significantly decreased electromyography activity (p < 0, 05) and the SH increased (p < 0.05) compared to the control group. For the rest of the muscles, there was no significantly difference between the groups. It was verified that the experimental group presented higher co-contraction of the mandible depressed muscles in relation to contraction of the RT LT, RM and LM, as compared to the control group (p < 0.05).</p><p><strong>Conclusions: </strong>Dysphonic women present alteration of the activation patterns of the masticatory muscles.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 6","pages":"289-94"},"PeriodicalIF":0.0,"publicationDate":"2010-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29456276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electromyographic validation of the muscles deltoid (anterior portion) and pectoralis major (clavicular portion) in military press exercises with open grip. 三角肌(前部)和胸大肌(锁骨部分)在开握军事压力练习中的肌电图验证。
M L Büll, M I Ferreira, M Vitti

It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.

采用双通道肌电图(tecate4)和惠普表面电极,对24名男性志愿者在4种开放握力的军事压力练习模式下的三角肌前部和胸大肌锁骨部分进行了分析。结果显示PMC在几乎所有模式中都高度不活跃,而DA在所有评估模式中都表现出非常高的动作电位水平。
{"title":"Electromyographic validation of the muscles deltoid (anterior portion) and pectoralis major (clavicular portion) in military press exercises with open grip.","authors":"M L Büll,&nbsp;M I Ferreira,&nbsp;M Vitti","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"203-11"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29196938","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modulation of the ipsilateral and contralateral H reflexes following ipsilateral mechanical pressure of the foot in normal subjects. 正常人同侧足部机械压力对同侧和对侧H反射的调节。
A Bastani, M R Hadian, S Talebian, H Bagheri, G R Olyaie

Objective: Mechanoreceptors from the foot sole likely contribute in the reflex regulations. Therefore, it was hypothesized that repetitive low threshold afferents stimulation would have an inhibitory effect on the soleus H-reflexes.

Methods: Sixteen normal subjects voluntarily, participated in the study and were randomly allocated. Subjects were remained in prone position. The Cutaneous Mechanical Pressure (CMP equal to 50% of leg and foot weight) was applied to the ipsilateral lateral and Medial plantar surface by a designed instrument through a square plate (30 x 30 mm). H reflex as an indicator for excitability of motoneurones was bilaterally elicited before and after the application of the CMP. The H-reflex parameters were estimated.

Results: Mechanical pressure significantly depressed soleus H-reflex excitability in ipsilateral and contralateral feet in all subjects.

Conclusion: The demonstration of a decrease in H-reflex excitability as a result of applied pressure to the foot sole suggests that the change in reflex excitability is the result of a common spinal mechanism. The results highlight the modulatory effects that natural stimulation of afferents can have on reflex excitability.

Significance: The placement of a small flat plate, in order to apply pressure to the plantar eminence, may be useful for modulation of muscle tone. In addition, these findings might be useful for reducing spasticity; because spasticity is at least partially caused by hyperexcitability of the motorneuron pool.

目的:足底的机械感受器可能参与反射调节。因此,我们假设重复低阈传入刺激对比目鱼h反射有抑制作用。方法:16名正常受试者自愿参与研究,随机分配。受试者保持俯卧位。皮肤机械压力(CMP等于腿部和足部重量的50%)通过设计的仪器通过方形钢板(30 x 30 mm)施加于同侧外侧和内侧足底表面。H反射作为运动神经元兴奋性的指标,在应用CMP前后双侧被激发。估计h反射参数。结果:机械压力显著降低了所有受试者同侧和对侧足比目鱼h反射的兴奋性。结论:对足底施加压力导致h反射兴奋性降低,这表明反射兴奋性的变化是一种共同的脊柱机制的结果。结果强调了传入神经的自然刺激对反射兴奋性的调节作用。意义:放置一个小平板,以便对足底隆起施加压力,可能有助于调节肌肉张力。此外,这些发现可能有助于减少痉挛;因为痉挛至少部分是由运动神经元池的过度兴奋性引起的。
{"title":"Modulation of the ipsilateral and contralateral H reflexes following ipsilateral mechanical pressure of the foot in normal subjects.","authors":"A Bastani,&nbsp;M R Hadian,&nbsp;S Talebian,&nbsp;H Bagheri,&nbsp;G R Olyaie","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Objective: </strong>Mechanoreceptors from the foot sole likely contribute in the reflex regulations. Therefore, it was hypothesized that repetitive low threshold afferents stimulation would have an inhibitory effect on the soleus H-reflexes.</p><p><strong>Methods: </strong>Sixteen normal subjects voluntarily, participated in the study and were randomly allocated. Subjects were remained in prone position. The Cutaneous Mechanical Pressure (CMP equal to 50% of leg and foot weight) was applied to the ipsilateral lateral and Medial plantar surface by a designed instrument through a square plate (30 x 30 mm). H reflex as an indicator for excitability of motoneurones was bilaterally elicited before and after the application of the CMP. The H-reflex parameters were estimated.</p><p><strong>Results: </strong>Mechanical pressure significantly depressed soleus H-reflex excitability in ipsilateral and contralateral feet in all subjects.</p><p><strong>Conclusion: </strong>The demonstration of a decrease in H-reflex excitability as a result of applied pressure to the foot sole suggests that the change in reflex excitability is the result of a common spinal mechanism. The results highlight the modulatory effects that natural stimulation of afferents can have on reflex excitability.</p><p><strong>Significance: </strong>The placement of a small flat plate, in order to apply pressure to the plantar eminence, may be useful for modulation of muscle tone. In addition, these findings might be useful for reducing spasticity; because spasticity is at least partially caused by hyperexcitability of the motorneuron pool.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"251-6"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29197337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of fingertip contact with a wall on postural sway and electromyographyic activity of the soleus muscle. 指尖与壁接触对体位摆动和比目鱼肌肌电活动的影响。
S Watanabe, K Kobara, H Ishida

Standing and walking balance decreases in many kinds of neuromuscular, musculoskeletal and sensory disorders, and in elderly people because of age-related physiologic diminution. Recent studies have shown that contact cues from a cane or a fingertip provide information that leads to reduced postural sway in subjects. The first purpose of this study was to investigate the influence of light and forceful fingertip contacts with a wall on the postural sway while standing upright. The second purpose was to investigate the influence of fingertip contact on the EMG activity of the soleus muscle. Twelve healthy male volunteers (20.8 +/- 0.7 years old) participated in this study. Standing balance or postural sway was measured by sway of the center of pressure (COP) under three conditions: (1) standing without touching a wall, (2) standing with the right index fingertip lightly touching (< 1N) to a wall (3), and standing with the right index fingertip forcefully touching (5 approximately 10N) to a wall. Bipolar surface electrodes were placed over the right soleus muscle to measure EMG activity associated with anterior-posterior sway. More significant length, and rectangular and environmental areas of the COP were observed while standing without touching a wall than while standing while lightly or forcefully touching a wall, but there was no significant difference between the two touching conditions. No significant difference in the EMG activity of the soleus muscle was observed among the three conditions. The results of this study suggested that the fingertip touch contact with a wall decreased sway during static standing but did not influence the EMG activity of the soleus muscle.

站立和行走平衡在许多神经肌肉、肌肉骨骼和感觉障碍中下降,在老年人中由于年龄相关的生理减少。最近的研究表明,来自手杖或指尖的接触线索提供的信息可以减少受试者的姿势摇摆。本研究的第一个目的是研究直立站立时指尖与墙壁的轻微和有力接触对姿势摇摆的影响。第二个目的是研究指尖接触对比目鱼肌肌电活动的影响。12名健康男性志愿者(20.8±0.7岁)参加了本研究。在三种情况下,通过压力中心(COP)的摆动来测量站立平衡或姿势摇摆:(1)站立时不接触墙壁,(2)站立时右手食指轻微接触墙壁(< 1N),(3)站立时右手食指用力接触墙壁(约10N)。双极表面电极放置在右侧比目鱼肌上,测量与前后摇摆相关的肌电活动。站立不接触墙壁时,观察到的COP长度,矩形和环境区域比站立轻微或强力接触墙壁时更显著,但两种接触条件之间无显著差异。三种情况下比目鱼肌肌电活动无显著差异。这项研究的结果表明,指尖与墙壁的接触减少了静态站立时的摇摆,但不影响比目鱼肌的肌电活动。
{"title":"Influence of fingertip contact with a wall on postural sway and electromyographyic activity of the soleus muscle.","authors":"S Watanabe,&nbsp;K Kobara,&nbsp;H Ishida","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Standing and walking balance decreases in many kinds of neuromuscular, musculoskeletal and sensory disorders, and in elderly people because of age-related physiologic diminution. Recent studies have shown that contact cues from a cane or a fingertip provide information that leads to reduced postural sway in subjects. The first purpose of this study was to investigate the influence of light and forceful fingertip contacts with a wall on the postural sway while standing upright. The second purpose was to investigate the influence of fingertip contact on the EMG activity of the soleus muscle. Twelve healthy male volunteers (20.8 +/- 0.7 years old) participated in this study. Standing balance or postural sway was measured by sway of the center of pressure (COP) under three conditions: (1) standing without touching a wall, (2) standing with the right index fingertip lightly touching (< 1N) to a wall (3), and standing with the right index fingertip forcefully touching (5 approximately 10N) to a wall. Bipolar surface electrodes were placed over the right soleus muscle to measure EMG activity associated with anterior-posterior sway. More significant length, and rectangular and environmental areas of the COP were observed while standing without touching a wall than while standing while lightly or forcefully touching a wall, but there was no significant difference between the two touching conditions. No significant difference in the EMG activity of the soleus muscle was observed among the three conditions. The results of this study suggested that the fingertip touch contact with a wall decreased sway during static standing but did not influence the EMG activity of the soleus muscle.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"229-33"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29194691","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The effect of epoch length on the electromyographic mean power frequency and amplitude versus time relationships. epoch长度对肌电图平均工频和振幅随时间关系的影响。
C R Hendrix, T J Housh, G O Johnson, M Mielke, J M Zuniga, C L Camic, R J Schmidt

Unlabelled: The electromyographic (EMG) mean power frequency (MPF) and amplitude versus time relationships are commonly used to characterize localized muscle fatigue.

Purpose: The purpose of this study was to compare the effect of epoch length on the individual and mean slope coefficients and y-intercepts resulting from the EMG MPF and amplitude versus time relationships of the vastus medialis (VM) muscle during fatiguing isometric muscle actions at 30 and 75% of maximum voluntary isometric contraction (MVC).

Methods: Eight adults performed two continuous, isometric muscle actions of the leg extensors at 30 and 75% MVC to exhaustion. Six, 5.0 s epochs of the surface EMG signals were recorded from the VM during each minute. Epoch lengths of 0.5, 1.0, and 2.0 s were selected from the middle of each 5.0 s epoch. Linear regression was used to estimate the slope coefficient and y-intercept values for the EMG MPF and amplitude versus time relationships for each epoch length (0.5, 1.0, 2.0, and 5.0 s) and subject.

Results: There were no significant differences between epoch lengths for the individual or mean slope coefficients or y-intercepts (EMG MPF and amplitude versus time relationships).

Conclusion: This study indicated that epochs of 0.5 - 5.0 s resulted in the same characterization of EMG (MPF and amplitude) versus time relationships during isometric muscle actions.

未标记:肌电图(EMG)平均工频(MPF)和振幅与时间的关系通常用于表征局部肌肉疲劳。目的:本研究的目的是比较在最大自愿等距收缩(MVC)的30%和75%时,在疲劳等距肌肉运动中,时间长度对个体和平均斜率系数和y截距产生的影响,以及股内侧肌(VM)肌肉的振幅与时间关系。方法:8名成年人在30和75%的MVC下进行两次连续的腿伸肌等长肌肉运动,直到筋疲力尽。记录每分钟VM表面肌电信号的6、5.0 s epoch。从每个5.0 s Epoch的中间选取0.5、1.0和2.0 s的Epoch长度。使用线性回归估计每个历元长度(0.5、1.0、2.0和5.0 s)和受试者的肌电强积金和振幅随时间的关系的斜率系数和y截距值。结果:个体或平均斜率系数或y截距的历元长度之间没有显著差异(肌电强积金和振幅与时间的关系)。结论:0.5 ~ 5.0 s的时间点在肌等长运动过程中具有相同的肌电特征(强积金和振幅)和时间关系。
{"title":"The effect of epoch length on the electromyographic mean power frequency and amplitude versus time relationships.","authors":"C R Hendrix,&nbsp;T J Housh,&nbsp;G O Johnson,&nbsp;M Mielke,&nbsp;J M Zuniga,&nbsp;C L Camic,&nbsp;R J Schmidt","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Unlabelled: </strong>The electromyographic (EMG) mean power frequency (MPF) and amplitude versus time relationships are commonly used to characterize localized muscle fatigue.</p><p><strong>Purpose: </strong>The purpose of this study was to compare the effect of epoch length on the individual and mean slope coefficients and y-intercepts resulting from the EMG MPF and amplitude versus time relationships of the vastus medialis (VM) muscle during fatiguing isometric muscle actions at 30 and 75% of maximum voluntary isometric contraction (MVC).</p><p><strong>Methods: </strong>Eight adults performed two continuous, isometric muscle actions of the leg extensors at 30 and 75% MVC to exhaustion. Six, 5.0 s epochs of the surface EMG signals were recorded from the VM during each minute. Epoch lengths of 0.5, 1.0, and 2.0 s were selected from the middle of each 5.0 s epoch. Linear regression was used to estimate the slope coefficient and y-intercept values for the EMG MPF and amplitude versus time relationships for each epoch length (0.5, 1.0, 2.0, and 5.0 s) and subject.</p><p><strong>Results: </strong>There were no significant differences between epoch lengths for the individual or mean slope coefficients or y-intercepts (EMG MPF and amplitude versus time relationships).</p><p><strong>Conclusion: </strong>This study indicated that epochs of 0.5 - 5.0 s resulted in the same characterization of EMG (MPF and amplitude) versus time relationships during isometric muscle actions.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"219-27"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29196940","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Which parameter is more reliable in a cold hand, NCV or latency. 哪个参数在冷手中更可靠,NCV还是延迟。
S M Jazayeri Shooshtari, S Abolahrari, P Sedaghat, S H Taghizadeh, H Gbaem, A R Moghtaderi

Temperature affects distal sensory & motor latencies & nerve conduction velocity but not necessarily at the same degree. Purpose of this study is to see which one is affected less and thus could be more reliable in cold conditions. A total of 32 healthy individuals with age range of 18-28 years (mean 22.25 +/- 2.2) participated in this study. Skin Temperature was recorded at wrist. Distal median motor & sensory latencies and transcarpal median NCV were recorded before and after immersion in cold water. Statistical analysis was performed using paired t-test with SPSS. All parameters were affected by cold but the effect was less dramatic in transcarpal NCV. Transcarpal median NCV is least affected parameter by cold, so it may be more reliable than sensory & motor latencies at wrist.

温度影响远端感觉和运动潜伏期以及神经传导速度,但程度不一定相同。这项研究的目的是看看哪一个受影响较小,从而在寒冷条件下更可靠。共32名年龄在18-28岁之间的健康个体(平均22.25±2.2)参加了本研究。记录腕部皮肤温度。记录冷水浸泡前后远端正中运动和感觉潜伏期及经腕正中NCV。统计学分析采用SPSS软件配对t检验。所有参数均受寒冷影响,但经腕部NCV的影响较小。经腕正中NCV是受寒冷影响最小的参数,因此可能比手腕的感觉和运动潜伏期更可靠。
{"title":"Which parameter is more reliable in a cold hand, NCV or latency.","authors":"S M Jazayeri Shooshtari,&nbsp;S Abolahrari,&nbsp;P Sedaghat,&nbsp;S H Taghizadeh,&nbsp;H Gbaem,&nbsp;A R Moghtaderi","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Temperature affects distal sensory & motor latencies & nerve conduction velocity but not necessarily at the same degree. Purpose of this study is to see which one is affected less and thus could be more reliable in cold conditions. A total of 32 healthy individuals with age range of 18-28 years (mean 22.25 +/- 2.2) participated in this study. Skin Temperature was recorded at wrist. Distal median motor & sensory latencies and transcarpal median NCV were recorded before and after immersion in cold water. Statistical analysis was performed using paired t-test with SPSS. All parameters were affected by cold but the effect was less dramatic in transcarpal NCV. Transcarpal median NCV is least affected parameter by cold, so it may be more reliable than sensory & motor latencies at wrist.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"235-8"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29194692","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Lateral inclination of the trunk and falling frequency in Parkinson's disease patients. 帕金森病患者躯干侧倾与跌倒频率的关系。
Ryoichi Hayashi, Junpei Aizawa, Hiroyuki Nagase, Shinji Ohara

Objective: To investigate clinical features of postural instability and the relationship between severity of instability and falls during daily living in patients with Parkinson's disease (PD).

Methods and subjects: We recorded trunk movements of subjects maintaining a seated position for 2 minutes using both a force plate and a position sensor system. We compared 13 patients with falls (fallers), 7 without falls (non-fallers), and 8 age-matched normal controls.

Results: The tendency for the values of both lateral COP displacement and trunk displacement was to increase in 1) patients compared with controls, and 2) fallers compared to non-fallers. Among patients who showed a large value of lateral COP displacement, greater than the value of the mean plus one standard deviation of controls, 90% had lumbar scoliosis and 60% of these patients fell down more than 5 times during the one-year follow-up period.

Conclusion: We demonstrated that PD patients who had fallen frequently tended to have a 1) lumbar scoliosis, and 2) large value of lateral COP displacement. These results suggest that the measurement of both lateral COP displacement during sitting and spinal curvature would be useful in predicting the risk of falling in PD patients.

目的:探讨帕金森病(PD)患者体位不稳定的临床特征及不稳定程度与日常生活跌倒的关系。方法和对象:我们使用测力板和位置传感器系统记录受试者保持坐姿2分钟的躯干运动。我们比较了13例跌倒患者(跌倒者),7例未跌倒患者(非跌倒者)和8例年龄匹配的正常对照。结果:侧侧COP位移值和躯干位移值在1)患者中比在对照组中增加,在2)跌倒者中比在非跌倒者中增加。在侧侧COP位移值较大,大于对照组平均值加一个标准差的患者中,90%的患者发生腰椎侧凸,其中60%的患者在1年随访期间跌倒超过5次。结论:我们证明,经常摔倒的PD患者往往有1)腰椎侧凸,2)侧侧COP移位大值。这些结果表明,坐位时侧位COP位移和脊柱弯曲度的测量将有助于预测PD患者跌倒的风险。
{"title":"Lateral inclination of the trunk and falling frequency in Parkinson's disease patients.","authors":"Ryoichi Hayashi,&nbsp;Junpei Aizawa,&nbsp;Hiroyuki Nagase,&nbsp;Shinji Ohara","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Objective: </strong>To investigate clinical features of postural instability and the relationship between severity of instability and falls during daily living in patients with Parkinson's disease (PD).</p><p><strong>Methods and subjects: </strong>We recorded trunk movements of subjects maintaining a seated position for 2 minutes using both a force plate and a position sensor system. We compared 13 patients with falls (fallers), 7 without falls (non-fallers), and 8 age-matched normal controls.</p><p><strong>Results: </strong>The tendency for the values of both lateral COP displacement and trunk displacement was to increase in 1) patients compared with controls, and 2) fallers compared to non-fallers. Among patients who showed a large value of lateral COP displacement, greater than the value of the mean plus one standard deviation of controls, 90% had lumbar scoliosis and 60% of these patients fell down more than 5 times during the one-year follow-up period.</p><p><strong>Conclusion: </strong>We demonstrated that PD patients who had fallen frequently tended to have a 1) lumbar scoliosis, and 2) large value of lateral COP displacement. These results suggest that the measurement of both lateral COP displacement during sitting and spinal curvature would be useful in predicting the risk of falling in PD patients.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"195-202"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29196937","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of postural oscillation in children with cerebral palsy. 脑瘫患儿体位振荡的分析。
A Nobre, F F Monteiro, M O Golin, D Biasotto-Gonzalez, J C Ferrari Corrêa, C S Oliveira

It is believed that static balance undergoes changes in children with cerebral palsy (CP). Thus, we analyzed postural oscillation in 19 children with the aim of comparing balance between healthy children and those with CP. The sample was divided into two groups--one with 10 children diagnosed with diparetic CP (CPG) and a control group (CG) with nine healthy children, all capable of remaining in an orthostatic position without support and obeying spoken commands. The assessment of postural oscillation was performed with the children barefoot, arms alongside the body and looking toward a fixed point while standing on an unrestricted base for the feet. Data collection was performed using a TEKScan force platform with 30-second duration for each condition. The children had an average age of 7.9 years (+/- 2.07) in the CPG and 7.5 years (+/- 1.58) for the CG. Postural oscillation data in the anterior-posterior and medial-lateral directions were analyzed using the Data Analysis and Technical Graphics Origin 6.0 program. Statistical analysis of the mean oscillation value in the conditions of eyes open and eyes closed did not differ significantly between groups. However, there was a significant difference in mean anterior-posterior oscillation between groups (p = 0.00). The groups behaved similarly with regard to the visual deprivation. We conclude that children with CP exhibit less postural oscillation in comparison to healthy children under the same conditions.

人们认为,静态平衡在脑瘫(CP)患儿中发生变化。因此,我们分析了19名儿童的体位振荡,目的是比较健康儿童和CP儿童之间的平衡。样本分为两组,一组有10名诊断为diparetic CP (CPG)的儿童,另一组有9名健康儿童(CG),所有儿童都能够在没有支持的情况下保持直立姿势并服从口头命令。姿势振荡的评估是在孩子们赤脚,手臂在身体旁边,站在一个不受限制的脚基座上,看着一个固定点的情况下进行的。使用TEKScan力平台进行数据收集,每种情况持续30秒。患儿CPG组平均年龄7.9岁(±2.07),CG组平均年龄7.5岁(±1.58)。采用data Analysis和Technical Graphics Origin 6.0程序分析前后方向和中外侧方向的体位振荡数据。睁眼和闭眼条件下的平均振荡值在组间无统计学差异。然而,两组之间的平均前后振荡有显著差异(p = 0.00)。两组在视觉剥夺方面表现相似。我们的结论是,在相同的条件下,与健康儿童相比,患有CP的儿童表现出较少的姿势振荡。
{"title":"Analysis of postural oscillation in children with cerebral palsy.","authors":"A Nobre,&nbsp;F F Monteiro,&nbsp;M O Golin,&nbsp;D Biasotto-Gonzalez,&nbsp;J C Ferrari Corrêa,&nbsp;C S Oliveira","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>It is believed that static balance undergoes changes in children with cerebral palsy (CP). Thus, we analyzed postural oscillation in 19 children with the aim of comparing balance between healthy children and those with CP. The sample was divided into two groups--one with 10 children diagnosed with diparetic CP (CPG) and a control group (CG) with nine healthy children, all capable of remaining in an orthostatic position without support and obeying spoken commands. The assessment of postural oscillation was performed with the children barefoot, arms alongside the body and looking toward a fixed point while standing on an unrestricted base for the feet. Data collection was performed using a TEKScan force platform with 30-second duration for each condition. The children had an average age of 7.9 years (+/- 2.07) in the CPG and 7.5 years (+/- 1.58) for the CG. Postural oscillation data in the anterior-posterior and medial-lateral directions were analyzed using the Data Analysis and Technical Graphics Origin 6.0 program. Statistical analysis of the mean oscillation value in the conditions of eyes open and eyes closed did not differ significantly between groups. However, there was a significant difference in mean anterior-posterior oscillation between groups (p = 0.00). The groups behaved similarly with regard to the visual deprivation. We conclude that children with CP exhibit less postural oscillation in comparison to healthy children under the same conditions.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"239-44"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29195167","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cross-talk among monopolar surface electromyographic signals from the superficial quadriceps femoris muscles. 股四头肌浅表肌单极表面肌电信号的串扰。
T W Beck, J M DeFreitas, M S Stock

This study used a within-subjects design. The purpose of this study was to examine cross-talk among monopolar surface electromyographic (EMG) signals from the superficial quadriceps femoris muscles. The "efficiency of electrical activity" technique for assessing muscle function uses monopolar EMG. Thus, knowledge of the potential for cross-talk among the superficial quadriceps femoris muscles when using monopolar recording will be valuable in rehabilitative settings. Fourteen healthy men (mean +/- SD age = 22.0 +/- 3.9 years) volunteered to perform submaximal to maximal isometric muscle actions of the dominant leg extensors in 10% increments from 10% to 100% of the maximum voluntary contraction (MVC). During each muscle action, monopolar surface EMG signals were detected from the superficial quadriceps femoris muscles. Three separate cross-correlations were performed to examine cross-talk among the vastus lateralis and rectus femoris, vastus medialis and rectus femoris, and vastus lateralis and vastus medialis. The peak cross-correlation coefficients ranged from R(x,y) = 0.182-0.944, with the greatest cross-talk occurring between the vastus lateralis and vastus medialis. In addition, the cross-correlation coefficients generally increased with force. These findings showed moderate to large degrees of crosstalk among monopolar surface EMG signals from the superficial quadriceps femoris muscles. Thus, the monopolar EMG signals from these muscles should be interpreted carefully and with the understanding that at least a portion of the signal from each muscle is due to cross-talk.

本研究采用受试者内设计。本研究的目的是研究股四头肌浅表肌单极表面肌电图(EMG)信号之间的串扰。评估肌肉功能的“电活动效率”技术使用单极肌电图。因此,当使用单极记录时,了解股四头肌浅表肌间潜在的串扰将在康复设置中有价值。14名健康男性(平均+/- SD年龄= 22.0 +/- 3.9岁)自愿以最大自愿收缩(MVC)的10%至100%的10%增量进行优势腿伸肌的次至最大等距肌肉动作。在每次肌肉运动过程中,从股四头肌浅表肌检测到单极表面肌电信号。通过三个独立的相互关联来检查股外侧肌与股直肌、股内侧肌与股直肌、股外侧肌与股内侧肌之间的交叉。最大的交叉相关系数R(x,y) = 0.182 ~ 0.944,其中股外侧肌和股内侧肌之间的交叉相关最大。此外,相互关系系数一般随作用力增大而增大。这些发现表明,股四头肌浅表肌单极表面肌电信号之间存在中度至重度的串扰。因此,来自这些肌肉的单极肌电图信号应仔细解释,并理解来自每块肌肉的信号至少有一部分是由于串扰。
{"title":"Cross-talk among monopolar surface electromyographic signals from the superficial quadriceps femoris muscles.","authors":"T W Beck,&nbsp;J M DeFreitas,&nbsp;M S Stock","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This study used a within-subjects design. The purpose of this study was to examine cross-talk among monopolar surface electromyographic (EMG) signals from the superficial quadriceps femoris muscles. The \"efficiency of electrical activity\" technique for assessing muscle function uses monopolar EMG. Thus, knowledge of the potential for cross-talk among the superficial quadriceps femoris muscles when using monopolar recording will be valuable in rehabilitative settings. Fourteen healthy men (mean +/- SD age = 22.0 +/- 3.9 years) volunteered to perform submaximal to maximal isometric muscle actions of the dominant leg extensors in 10% increments from 10% to 100% of the maximum voluntary contraction (MVC). During each muscle action, monopolar surface EMG signals were detected from the superficial quadriceps femoris muscles. Three separate cross-correlations were performed to examine cross-talk among the vastus lateralis and rectus femoris, vastus medialis and rectus femoris, and vastus lateralis and vastus medialis. The peak cross-correlation coefficients ranged from R(x,y) = 0.182-0.944, with the greatest cross-talk occurring between the vastus lateralis and vastus medialis. In addition, the cross-correlation coefficients generally increased with force. These findings showed moderate to large degrees of crosstalk among monopolar surface EMG signals from the superficial quadriceps femoris muscles. Thus, the monopolar EMG signals from these muscles should be interpreted carefully and with the understanding that at least a portion of the signal from each muscle is due to cross-talk.</p>","PeriodicalId":11591,"journal":{"name":"Electromyography and clinical neurophysiology","volume":"50 5","pages":"245-50"},"PeriodicalIF":0.0,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29195169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Electromyography and clinical neurophysiology
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1