首页 > 最新文献

Revista de Medicina de Laboratorio最新文献

英文 中文
Study of alpha-thalassemia in the clinical laboratory: genotypes-phenotypes of clinical interest and their diagnostic approach α -地中海贫血的临床实验室研究:临床兴趣的基因型-表型及其诊断方法
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00116
H. López-Escribano, Ausias Hervás-Romero
{"title":"Study of alpha-thalassemia in the clinical laboratory: genotypes-phenotypes of clinical interest and their diagnostic approach","authors":"H. López-Escribano, Ausias Hervás-Romero","doi":"10.20960/revmedlab.00116","DOIUrl":"https://doi.org/10.20960/revmedlab.00116","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129629101","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High serum creatinine after intravenous dexamethasone administration 静脉注射地塞米松后血清肌酐升高
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00140
J. Pereira, A. Leão, Luís Araújo, N. Gonçalves, Gabriela Martins
{"title":"High serum creatinine after intravenous dexamethasone administration","authors":"J. Pereira, A. Leão, Luís Araújo, N. Gonçalves, Gabriela Martins","doi":"10.20960/revmedlab.00140","DOIUrl":"https://doi.org/10.20960/revmedlab.00140","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134295510","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Myeloid blasts in peripheral blood in newborn with Down syndrome, acute myeloid leukemia or transient abnormal myelopoiesis? 新生儿唐氏综合征、急性髓性白血病或短暂性髓性异常外周血中存在髓母细胞?
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00124
Maitane Echeverría Urroz, Laura Martínez González, Noelia López Barba, María Elena Redín Sarasola
{"title":"Myeloid blasts in peripheral blood in newborn with Down syndrome, acute myeloid leukemia or transient abnormal myelopoiesis?","authors":"Maitane Echeverría Urroz, Laura Martínez González, Noelia López Barba, María Elena Redín Sarasola","doi":"10.20960/revmedlab.00124","DOIUrl":"https://doi.org/10.20960/revmedlab.00124","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130315906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Seminal fluid anaphylaxis. A rare clinical condition 精液过敏反应罕见的临床状况
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00104
Marta Sofia Carvalho Fernandes, R. Fernandes, Cristina Lopes Abreu
{"title":"Seminal fluid anaphylaxis. A rare clinical condition","authors":"Marta Sofia Carvalho Fernandes, R. Fernandes, Cristina Lopes Abreu","doi":"10.20960/revmedlab.00104","DOIUrl":"https://doi.org/10.20960/revmedlab.00104","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129540985","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Hematocrit: an uncontrollable variable in newborn screening? 红细胞压积:新生儿筛查中的一个不可控变量?
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00148
Alejandro Mario Vilche Juárez, G. Dratler, S. Marino, Sofia Coniglio, Florencia Tommasi, S. Quiroga
Introduction: dried blood spots (dbs) are valuable samples for the newborn screening laboratory. Cut-off values for neonatal screening determinations are based on an average hematocrit value (55 %). Newborns that exceed the cut-off value of the determinations are cited again for a confirmatory sample collection. Objective: to develop a laboratory technique that allows knowing the value of the hematocrit in the dbs samples of neonatal screening and to study the impact of the hematocrit variable on the results of neonatal screening. Material and methods: 1124 samples from two neonatal screening laboratories were analyzed. The hematocrit in the DBS samples was estimated using immunoreactive trypsin (IRT), and 17-hydroxyprogesterone (17-OHP) were determined. The results were evaluated with and without hematocrit correction taking into account the estimated value. Results: 183 samples (without correction) exceeded the cut off value proposed by each laboratory: 49 for tsh, 44 for irt, and 90 for 17 OHP. Using the hematocrit estimation, 18 (36.7 %) newborns exceeded the TSH cut-off value, 25 (56.7 %) in the IRT measurement and 39 (43.3 %) in 17OHP determination. If the correction of the packed red cell had been used in the DBS samples, only 44.8% of the 183 newborns would have had to be cited again. Discussion: the estimation of the hematocrit would allow the correction of the volume in the dbs samples. We suggest the use of hematocrit estimation for samples that exceed the cut-off value. By lowering the percentage of requests for new samples we would avoid the anguish that it causes in the family.
简介:干血斑(dbs)是新生儿筛查实验室的宝贵样本。新生儿筛查确定的临界值是基于平均红细胞压积值(55%)。新生儿超过临界值的测定再次引用确认样本收集。目的:开发一种实验室技术,可以了解新生儿筛查dbs样本中红细胞压积的价值,并研究红细胞压积变量对新生儿筛查结果的影响。材料和方法:对两个新生儿筛查实验室1124份样本进行分析。使用免疫反应性胰蛋白酶(IRT)估计DBS样品中的红细胞压积,并测定17-羟基孕酮(17-OHP)。考虑到估计值,在有和没有血细胞比容校正的情况下对结果进行评估。结果:183份样品(未校正)超过各实验室建议的截止值:tsh 49份,irt 44份,OHP 17份。使用红细胞压积估计,18例(36.7%)新生儿超过TSH临界值,25例(56.7%)在IRT测量中,39例(43.3%)在17OHP测定中。如果在DBS样本中使用填充红细胞的校正,183名新生儿中只有44.8%需要再次引用。讨论:红细胞压积的估计将允许校正dbs样品的体积。我们建议对超过临界值的样本使用红细胞压积估计。通过降低索要新样品的比例,我们可以避免它给家庭带来的痛苦。
{"title":"Hematocrit: an uncontrollable variable in newborn screening?","authors":"Alejandro Mario Vilche Juárez, G. Dratler, S. Marino, Sofia Coniglio, Florencia Tommasi, S. Quiroga","doi":"10.20960/revmedlab.00148","DOIUrl":"https://doi.org/10.20960/revmedlab.00148","url":null,"abstract":"Introduction: dried blood spots (dbs) are valuable samples for the newborn screening laboratory. Cut-off values for neonatal screening determinations are based on an average hematocrit value (55 %). Newborns that exceed the cut-off value of the determinations are cited again for a confirmatory sample collection. Objective: to develop a laboratory technique that allows knowing the value of the hematocrit in the dbs samples of neonatal screening and to study the impact of the hematocrit variable on the results of neonatal screening. Material and methods: 1124 samples from two neonatal screening laboratories were analyzed. The hematocrit in the DBS samples was estimated using immunoreactive trypsin (IRT), and 17-hydroxyprogesterone (17-OHP) were determined. The results were evaluated with and without hematocrit correction taking into account the estimated value. Results: 183 samples (without correction) exceeded the cut off value proposed by each laboratory: 49 for tsh, 44 for irt, and 90 for 17 OHP. Using the hematocrit estimation, 18 (36.7 %) newborns exceeded the TSH cut-off value, 25 (56.7 %) in the IRT measurement and 39 (43.3 %) in 17OHP determination. If the correction of the packed red cell had been used in the DBS samples, only 44.8% of the 183 newborns would have had to be cited again. Discussion: the estimation of the hematocrit would allow the correction of the volume in the dbs samples. We suggest the use of hematocrit estimation for samples that exceed the cut-off value. By lowering the percentage of requests for new samples we would avoid the anguish that it causes in the family.","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116486528","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Diagnosis: chyluria 诊断:乳糜尿
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00083
Araceli Carrasco Mora, Luz del Mar Rivas Chacón, Verónica Benito Zamorano
{"title":"Diagnosis: chyluria","authors":"Araceli Carrasco Mora, Luz del Mar Rivas Chacón, Verónica Benito Zamorano","doi":"10.20960/revmedlab.00083","DOIUrl":"https://doi.org/10.20960/revmedlab.00083","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"17 s1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132360241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cholesterol crystals in pericardial fluid 心包液中胆固醇结晶
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00114
Maialen Ormazábal Monterrubio, Romina García Sardina, Pedro José Espinosa Prados
{"title":"Cholesterol crystals in pericardial fluid","authors":"Maialen Ormazábal Monterrubio, Romina García Sardina, Pedro José Espinosa Prados","doi":"10.20960/revmedlab.00114","DOIUrl":"https://doi.org/10.20960/revmedlab.00114","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116323953","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Valor del ancho de distribución de monocitos (MDW) en infecciones por virus respiratorios 呼吸道病毒感染中单核细胞分布宽度(MDW)的值
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00171
Maialen Palomino Alonso, Fernando Calvo Boyero, Sandra Gómez Rojas
{"title":"Valor del ancho de distribución de monocitos (MDW) en infecciones por virus respiratorios","authors":"Maialen Palomino Alonso, Fernando Calvo Boyero, Sandra Gómez Rojas","doi":"10.20960/revmedlab.00171","DOIUrl":"https://doi.org/10.20960/revmedlab.00171","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"131 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122498746","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Carta al director: “Pseudohiperpotasemia por trombocitosis: una entidad a veces olvidada" 致主任的信:“血小板增多引起的假高钾血症:一个有时被遗忘的实体”
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00170
Natalia González Pereira, Adela Castañeda de la Mata, Santiago Prieto Menchero
{"title":"Carta al director: “Pseudohiperpotasemia por trombocitosis: una entidad a veces olvidada\"","authors":"Natalia González Pereira, Adela Castañeda de la Mata, Santiago Prieto Menchero","doi":"10.20960/revmedlab.00170","DOIUrl":"https://doi.org/10.20960/revmedlab.00170","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130198689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Estudio de intercambiabilidad entre dos métodos analíticos para la determinación del receptor soluble del activador del plasminógeno tipo urocinasa (suPAR) en el laboratorio de urgencias: inmunoensayo de flujo lateral frente a turbidimetría 急诊科测定尿激酶型纤溶酶原激活剂受体(suPAR)可溶性受体的两种分析方法的互换性研究:侧流免疫分析与浊度法
Pub Date : 1900-01-01 DOI: 10.20960/revmedlab.00152
María Esther Paniagua Arribas, Rosario Padilla Berdugo, Silvia Álvarez Kailis, Fernando Neria Serrano, Eva de las Nieves Rodríguez
{"title":"Estudio de intercambiabilidad entre dos métodos analíticos para la determinación del receptor soluble del activador del plasminógeno tipo urocinasa (suPAR) en el laboratorio de urgencias: inmunoensayo de flujo lateral frente a turbidimetría","authors":"María Esther Paniagua Arribas, Rosario Padilla Berdugo, Silvia Álvarez Kailis, Fernando Neria Serrano, Eva de las Nieves Rodríguez","doi":"10.20960/revmedlab.00152","DOIUrl":"https://doi.org/10.20960/revmedlab.00152","url":null,"abstract":"","PeriodicalId":273421,"journal":{"name":"Revista de Medicina de Laboratorio","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114241444","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Revista de Medicina de Laboratorio
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1