首页 > 最新文献

Al-Rafidain Engineering Journal (AREJ)最新文献

英文 中文
The Disaggregation Model via Non-Parametric Approach 非参数法的分类模型
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2024.144495.1302
Aisha Almokhtar, K. Almohseen, Shatha H. D. AL-Zakar
Flow disaggregation models, which are one of the stochastic generation techniques, play a crucial role in the planning, design, and operation of water resource management systems and related projects. One distinguishing feature of these models is their ability to address the issue of missing observed data and compensate for it. They also enable the rescaling of data from a higher temporal level to a lower temporal scale. Data at lower temporal scales are typically required to address hydraulic and operational design problems in water resource projects. There are two main approaches to disaggregation flow data: the parametric approach and the non-parametric approach.One of the advantages of the disaggregation model is its ability to distribute flow data values from a key station to several sub-stations, both temporally and/or spatially, while preserving the basic statistical properties of the time series obtained from the model (mean, standard deviation, minimum, maximum, and correlation coefficient) for the observed data.In the current study, a non-parametric approach was used for the purpose of disaggregation approach. It is assumed that there is aggregated discharge data at a key station, and this data will be disaggregated into a corresponding series of discharges temporally and spatially at sub-stations that are statistically similar, using the SAMS 2010 platform program (Stochastic Analysis, Modeling, and Simulation). Annual and monthly discharge data for five stations measuring discharges on the Tigris River System in Iraq were used, including the Mosul Dam station on the Tigris River, the Asmawah station on the Khazir River, the Askiklik station on the Upper Zab, the Dibs Dam station on the Lower Zab, and the Baiji station on the Tigris River, covering a time span of twenty-three years. The statistical results of the disaggregation approach were compared with their observed counterparts and showed good agreement in most years and months and for all stations. Based on this, the method is recommended disaggregation of the data when decisions required water management strategies in these regions.
流量分解模型是随机生成技术的一种,在水资源管理系统和相关项目的规划、设计和运行中发挥着至关重要的作用。这些模型的一个显著特点是能够解决观测数据缺失的问题,并对其进行补偿。它们还能将数据从较高的时间尺度重新调整到较低的时间尺度。要解决水资源项目中的水力和运行设计问题,通常需要较低时间尺度的数据。分解流量数据的方法主要有两种:参数法和非参数法。分解模型的优点之一是能够在时间和/或空间上将一个关键站的流量数据值分配到多个子站,同时保留从模型中获得的观测数据时间序列的基本统计属性(平均值、标准差、最小值、最大值和相关系数)。假定关键站点有总的排水量数据,利用 SAMS 2010 平台程序(随机分析、建模和仿真),将这些数据分解为统计上相似的子站点在时间和空间上的相应排水量系列。使用了伊拉克底格里斯河水系五个排水测量站的年度和月度排水数据,包括底格里斯河上的摩苏尔大坝站、卡齐尔河上的阿斯玛瓦站、上扎布河上的阿斯基克里克站、下扎布河上的迪布斯大坝站和底格里斯河上的拜吉站,时间跨度为 23 年。将分类方法的统计结果与观测结果进行了比较,结果表明,在大多数年份和月份,所有站点的统计结果都非常吻合。在此基础上,建议在这些地区制定必要的水管理战略决策时采用该方法对数据进行分类。
{"title":"The Disaggregation Model via Non-Parametric Approach","authors":"Aisha Almokhtar, K. Almohseen, Shatha H. D. AL-Zakar","doi":"10.33899/rengj.2024.144495.1302","DOIUrl":"https://doi.org/10.33899/rengj.2024.144495.1302","url":null,"abstract":"Flow disaggregation models, which are one of the stochastic generation techniques, play a crucial role in the planning, design, and operation of water resource management systems and related projects. One distinguishing feature of these models is their ability to address the issue of missing observed data and compensate for it. They also enable the rescaling of data from a higher temporal level to a lower temporal scale. Data at lower temporal scales are typically required to address hydraulic and operational design problems in water resource projects. There are two main approaches to disaggregation flow data: the parametric approach and the non-parametric approach.One of the advantages of the disaggregation model is its ability to distribute flow data values from a key station to several sub-stations, both temporally and/or spatially, while preserving the basic statistical properties of the time series obtained from the model (mean, standard deviation, minimum, maximum, and correlation coefficient) for the observed data.In the current study, a non-parametric approach was used for the purpose of disaggregation approach. It is assumed that there is aggregated discharge data at a key station, and this data will be disaggregated into a corresponding series of discharges temporally and spatially at sub-stations that are statistically similar, using the SAMS 2010 platform program (Stochastic Analysis, Modeling, and Simulation). Annual and monthly discharge data for five stations measuring discharges on the Tigris River System in Iraq were used, including the Mosul Dam station on the Tigris River, the Asmawah station on the Khazir River, the Askiklik station on the Upper Zab, the Dibs Dam station on the Lower Zab, and the Baiji station on the Tigris River, covering a time span of twenty-three years. The statistical results of the disaggregation approach were compared with their observed counterparts and showed good agreement in most years and months and for all stations. Based on this, the method is recommended disaggregation of the data when decisions required water management strategies in these regions.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"6 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140083848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Underwater Robotics: Principles, Components, Modeling, and ‎Control 水下机器人:原理、组件、建模和控制
Pub Date : 2024-03-01 DOI: 10.33899/arej.2024.182561
Ali Rasheed, Rabee Hagem, A. Khidhir, Omar Hazim
Underwater robotic systems have profoundly transformed the field of deep-sea exploration, enabling operations in remote subsea installations. The outlook for this technology is highly promising. This study aims to offer an in-depth understanding of the subject matter to postgraduate students, engineers, and researchers with a keen interest in the realm of underwater robotics. Furthermore, this work encompasses a comprehensive survey of the diverse domains within the field of underwater robotics
水下机器人系统深刻地改变了深海勘探领域,使远程海底设施的作业成为可能。这项技术的前景非常广阔。本研究旨在让对水下机器人技术领域有浓厚兴趣的研究生、工程师和研究人员深入了解这一主题。此外,本研究还对水下机器人技术领域的不同领域进行了全面调查
{"title":"Underwater Robotics: Principles, Components, Modeling, and ‎Control","authors":"Ali Rasheed, Rabee Hagem, A. Khidhir, Omar Hazim","doi":"10.33899/arej.2024.182561","DOIUrl":"https://doi.org/10.33899/arej.2024.182561","url":null,"abstract":"Underwater robotic systems have profoundly transformed the field of deep-sea exploration, enabling operations in remote subsea installations. The outlook for this technology is highly promising. This study aims to offer an in-depth understanding of the subject matter to postgraduate students, engineers, and researchers with a keen interest in the realm of underwater robotics. Furthermore, this work encompasses a comprehensive survey of the diverse domains within the field of underwater robotics","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"22 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140086084","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermodynamic Design of 10 TR Single-Effect LiBr-H2O Absorption Refrigeration System 10 TR 单效 LiBr-H2O 吸收式制冷系统的热力学设计
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.142266.1274
Soufyan Al-Osman, Saddam Mohammad
The use of energy, which is perceived as a key element in the development of civilization and is necessary for all aspects of modern life, is one of the measures of the country's growth. Due to the high costs of conventional energy sources as well as the possibility of their depletion, it has become necessary to look for new and direct sources of energy. As a result, thinking began to return to absorption cooling systems due to their ability to work using direct thermal energy. Apart from their simplicity and lack of moving parts, absorption cooling systems are commonly used because they can operate by a heat source with relatively low temperatures, such as those generated by burning natural gas or by solar collectors, to produce a refrigeration effect directly by evaporating the refrigerant. This article presented a thermodynamic design of (10 TR) single-effect (LiBr/ H 2 O) absorption refrigeration system. The capacity of the evaporator (35.17 KW) was used to determine the operating parameters for each component. Thermodynamic simulations are carried out on the basis of experimental correlations. To determine the various operational parameters of a vapor absorption refrigeration system under various operating conditions, a MATLAB code was developed. The effectiveness of the solution heat exchanger and the various temperatures of the generator, condenser, evaporator, absorber, are taken into consideration when calculating the coefficient of performance. The results obtained prove that the coefficient of performance increases by increasing the effectiveness of solution heat exchanger, generator and evaporator temperatures, and decreases by increasing absorber and condenser temperatures.
能源被视为文明发展的关键因素,是现代生活各个方面所必需的,能源的使用是国家发展的措施之一。由于传统能源成本高昂,而且有可能枯竭,因此有必要寻找新的直接能源。因此,人们开始重新考虑吸收式冷却系统,因为这种系统能够利用直接热能工作。吸收式制冷系统除了操作简单、没有活动部件外,还因为它可以利用温度相对较低的热源(如天然气燃烧或太阳能集热器产生的热源),通过蒸发制冷剂直接产生制冷效果,因而得到了广泛应用。本文介绍了(10 TR)单效(LiBr/ H 2 O)吸收式制冷系统的热力学设计。蒸发器的容量(35.17 千瓦)被用来确定每个组件的运行参数。热力学模拟是在实验相关性的基础上进行的。为了确定蒸汽吸收制冷系统在各种运行条件下的各种运行参数,开发了一套 MATLAB 代码。在计算性能系数时,考虑了溶液热交换器的有效性以及发生器、冷凝器、蒸发器和吸收器的不同温度。结果证明,溶液热交换器的效率、发电机和蒸发器的温度越高,性能系数越大;吸收器和冷凝器的温度越高,性能系数越小。
{"title":"Thermodynamic Design of 10 TR Single-Effect LiBr-H2O Absorption Refrigeration System","authors":"Soufyan Al-Osman, Saddam Mohammad","doi":"10.33899/rengj.2023.142266.1274","DOIUrl":"https://doi.org/10.33899/rengj.2023.142266.1274","url":null,"abstract":"The use of energy, which is perceived as a key element in the development of civilization and is necessary for all aspects of modern life, is one of the measures of the country's growth. Due to the high costs of conventional energy sources as well as the possibility of their depletion, it has become necessary to look for new and direct sources of energy. As a result, thinking began to return to absorption cooling systems due to their ability to work using direct thermal energy. Apart from their simplicity and lack of moving parts, absorption cooling systems are commonly used because they can operate by a heat source with relatively low temperatures, such as those generated by burning natural gas or by solar collectors, to produce a refrigeration effect directly by evaporating the refrigerant. This article presented a thermodynamic design of (10 TR) single-effect (LiBr/ H 2 O) absorption refrigeration system. The capacity of the evaporator (35.17 KW) was used to determine the operating parameters for each component. Thermodynamic simulations are carried out on the basis of experimental correlations. To determine the various operational parameters of a vapor absorption refrigeration system under various operating conditions, a MATLAB code was developed. The effectiveness of the solution heat exchanger and the various temperatures of the generator, condenser, evaporator, absorber, are taken into consideration when calculating the coefficient of performance. The results obtained prove that the coefficient of performance increases by increasing the effectiveness of solution heat exchanger, generator and evaporator temperatures, and decreases by increasing absorber and condenser temperatures.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"14 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140083644","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Advanced Techniques for Enhancing Low-Noise Amplifier Performance: A Review 增强低噪声放大器性能的先进技术:综述
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.144224.1295
Serri Saleh, Khalid Mohammed, Mohammad Yaseen, Hashim H. Hausien
This paper reviews prior investigations into low noise amplifier (LNA) design. In this work, various modern LNA architectures will be examined, with a focus on five technologies: Cascode Distributed LNA, Coupled-Line Feedback in 0.15-m GaAs pHEMT Technology, Dual-Band CMOS LNA in 65-nm CMOS, CMOS LNA Using Post-distortion technique and 22-nm FD-SOI CMOS. In this review, Low power dissipation rate, input and output synchronization, high gain, and low noise levels are examined. In order to design a new successful LNA, each topology's performance is then examined. Future research will be conducted based on comparisons of these five topologies
本文回顾了之前对低噪声放大器 (LNA) 设计的研究。本文将研究各种现代 LNA 架构,重点关注五种技术:级联分布式 LNA、0.15m GaAs pHEMT 技术中的耦合线反馈、65-nm CMOS 中的双频 CMOS LNA、使用后失真技术的 CMOS LNA 和 22-nm FD-SOI CMOS。本综述探讨了低功率耗散率、输入和输出同步、高增益和低噪音水平等问题。为了设计出新的成功低噪声放大器,将对每种拓扑结构的性能进行研究。未来的研究将在对这五种拓扑结构进行比较的基础上进行。
{"title":"Advanced Techniques for Enhancing Low-Noise Amplifier Performance: A Review","authors":"Serri Saleh, Khalid Mohammed, Mohammad Yaseen, Hashim H. Hausien","doi":"10.33899/rengj.2023.144224.1295","DOIUrl":"https://doi.org/10.33899/rengj.2023.144224.1295","url":null,"abstract":"This paper reviews prior investigations into low noise amplifier (LNA) design. In this work, various modern LNA architectures will be examined, with a focus on five technologies: Cascode Distributed LNA, Coupled-Line Feedback in 0.15-m GaAs pHEMT Technology, Dual-Band CMOS LNA in 65-nm CMOS, CMOS LNA Using Post-distortion technique and 22-nm FD-SOI CMOS. In this review, Low power dissipation rate, input and output synchronization, high gain, and low noise levels are examined. In order to design a new successful LNA, each topology's performance is then examined. Future research will be conducted based on comparisons of these five topologies","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"116 39","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140090512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Colour Theme Preferences for Elegant Residential Interior Design in Mosul City, Iraq 伊拉克摩苏尔市优雅住宅室内设计的色彩主题偏好
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.144199.1297
Oday Al-Chalabi
The interior space should achieve the users’ needs to achieve a high elegance and satisfaction level. Residential interior design in Mosul City in Iraq has less attention from the users and designers in terms of managing the colour theme. The technological era with imported interior design elements provided various options for designing interior spaces. Chaos in the arranging and coordination of interior design elements results from indifference to interior design principles linked to colour themes. The mismatching between users’ needs and designers’ purposes creates a negative elegant value. Therefore, the research problem is “The lack of strategies to deal with the colour theme in the residential interior design depending on the users' needs”. The study aims to identify the preferences for colour themes of elegant interior design in the residential interior space in Mosul City. The methodology applied a quantitative-qualitative approach using the survey, observation, and interview instruments. The visual observation of the interior design elements in furniture companies in Mosul City creates a platform for the availability of the material that provides a range of colour themes in Mosul City. The result showed that elegant design linked to nature and traditional factors of colour theme, while walls, furniture companies, and decorative are the influential elements.
室内空间应满足用户的需求,以达到高雅和满意的程度。伊拉克摩苏尔市的住宅室内设计在色彩主题管理方面较少受到用户和设计师的关注。科技时代,进口的室内设计元素为室内空间设计提供了多种选择。由于对与色彩主题相关的室内设计原则漠不关心,室内设计元素的安排和协调出现混乱。用户的需求与设计师的目的之间的不匹配造成了负面的高雅价值。因此,研究的问题是 "在住宅室内设计中缺乏根据用户需求处理色彩主题的策略"。本研究旨在确定摩苏尔市住宅室内空间优雅室内设计色彩主题的偏好。研究方法采用了定量-定性方法,使用了调查、观察和访谈工具。通过对摩苏尔市家具公司室内设计元素的直观观察,为摩苏尔市提供一系列色彩主题的材料的可用性创造了平台。结果显示,优雅的设计与自然和色彩主题的传统因素有关,而墙壁、家具公司和装饰则是有影响力的元素。
{"title":"The Colour Theme Preferences for Elegant Residential Interior Design in Mosul City, Iraq","authors":"Oday Al-Chalabi","doi":"10.33899/rengj.2023.144199.1297","DOIUrl":"https://doi.org/10.33899/rengj.2023.144199.1297","url":null,"abstract":"The interior space should achieve the users’ needs to achieve a high elegance and satisfaction level. Residential interior design in Mosul City in Iraq has less attention from the users and designers in terms of managing the colour theme. The technological era with imported interior design elements provided various options for designing interior spaces. Chaos in the arranging and coordination of interior design elements results from indifference to interior design principles linked to colour themes. The mismatching between users’ needs and designers’ purposes creates a negative elegant value. Therefore, the research problem is “The lack of strategies to deal with the colour theme in the residential interior design depending on the users' needs”. The study aims to identify the preferences for colour themes of elegant interior design in the residential interior space in Mosul City. The methodology applied a quantitative-qualitative approach using the survey, observation, and interview instruments. The visual observation of the interior design elements in furniture companies in Mosul City creates a platform for the availability of the material that provides a range of colour themes in Mosul City. The result showed that elegant design linked to nature and traditional factors of colour theme, while walls, furniture companies, and decorative are the influential elements.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":" January","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140092828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An Overview of Various Strategies for Dealing With The Under-Frequency Load Shedding Problem in Power Systems 处理电力系统欠频甩负荷问题的各种策略概述
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.139974.1251
Shawkat M. Younus, Abdulghani Abdulrazaq Al-Taei, Omar Al-Yozbaky, Imran Bashir
It's essential to maintain a consistent and dependable energy supplies given the rising global demand for energy. When there is a crisis, such as a malfunction or an imbalance between energy production and load demand, the Frequency system becomes unstable. A load shedding scheme is an important key to recover frequency system and ensure the obtainability of electrical power for serious loads in a plant. Therefore, it is necessary to provide reliable technologies to quickly and accurately way to prevent breakdown in the system energy. Under Frequency Load SheddingUFLS is one of the important systems protection, and as is currently the case in many instances, it is the final step to prevent the system's collapse following an interruption or failure energy in the system. In this paper , the review of the literature is presented, along with a look at the various methods employed in the electrical power system and a comparison of traditional, adaptive, and intelligent load-shedding strategies. In order to clarify the intended function (entity) and preserve system stability, extra classification of additional elements is suggested. The various load shedding systems were addressed, along with their benefits and drawbacks, and a comparison between them was made with a list of the most significant justifications for doing so.
鉴于全球能源需求不断增长,保持稳定可靠的能源供应至关重要。当出现故障或能源生产与负荷需求不平衡等危机时,频率系统就会变得不稳定。甩负荷方案是恢复频率系统和确保电厂重要负荷获得电力的重要关键。因此,有必要提供可靠的技术,快速、准确地防止系统能量中断。欠频甩负荷UFLS 是重要的系统保护之一,在目前的许多情况下,它是防止系统能量中断或故障后系统崩溃的最后一步。本文回顾了相关文献,介绍了电力系统中采用的各种方法,并对传统、自适应和智能甩负荷策略进行了比较。为了明确预期功能(实体)和维护系统稳定性,建议对附加元素进行额外分类。对各种甩负荷系统及其利弊进行了讨论,并对它们进行了比较,同时列出了这样做的最重要理由。
{"title":"An Overview of Various Strategies for Dealing With The Under-Frequency Load Shedding Problem in Power Systems","authors":"Shawkat M. Younus, Abdulghani Abdulrazaq Al-Taei, Omar Al-Yozbaky, Imran Bashir","doi":"10.33899/rengj.2023.139974.1251","DOIUrl":"https://doi.org/10.33899/rengj.2023.139974.1251","url":null,"abstract":"It's essential to maintain a consistent and dependable energy supplies given the rising global demand for energy. When there is a crisis, such as a malfunction or an imbalance between energy production and load demand, the Frequency system becomes unstable. A load shedding scheme is an important key to recover frequency system and ensure the obtainability of electrical power for serious loads in a plant. Therefore, it is necessary to provide reliable technologies to quickly and accurately way to prevent breakdown in the system energy. Under Frequency Load SheddingUFLS is one of the important systems protection, and as is currently the case in many instances, it is the final step to prevent the system's collapse following an interruption or failure energy in the system. In this paper , the review of the literature is presented, along with a look at the various methods employed in the electrical power system and a comparison of traditional, adaptive, and intelligent load-shedding strategies. In order to clarify the intended function (entity) and preserve system stability, extra classification of additional elements is suggested. The various load shedding systems were addressed, along with their benefits and drawbacks, and a comparison between them was made with a list of the most significant justifications for doing so.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"76 19","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140085399","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessing the Impact of Composite Salt-Contaminated Groundwater on compressive strength of Concrete Foundations: A Case Study in Basra, Iraq 评估复合盐污染地下水对混凝土地基抗压强度的影响:伊拉克巴士拉案例研究
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.141945.1270
Hayder A. O. Al-Deewan, Mohammad Almohammad-albakkar, Hussein Khudhair, Wadi AL-WADI
This study aims to investigate the impact of groundwater containing composite salts on the compressive strength of concrete foundations located in the city of Basra in Iraq. The groundwater in this city demonstrates high concentrations of salts, particularly significant amounts of magnesium, sodium, and calcium salts, which are present in close proximity to the soil surface. To accomplish this objective, a foundation in the mentioned city was selected, which has been constructed since 2012 and remains incomplete to this day. The chosen foundation covers an area of approximately 2000 m 2 . Samples were collected from seven distinct regions, with three samples obtained from each region, resulting in a total of 21 samples. The selected regions were those most affected by groundwater, specifically those closest to the soil, such as regions near edges or openings within the foundation. The results of compressive strength tests conducted on all specimens indicated a remarkable decline in compressive strength. On average, the findings revealed a 30% reduction in compressive strength, highlighting the significant impact of composite salt-contaminated groundwater on the durability of concrete foundations.
本研究旨在调查含复合盐的地下水对伊拉克巴士拉市混凝土地基抗压强度的影响。该城市的地下水中含有大量盐分,尤其是大量的镁、钠和钙盐,这些盐分都存在于土壤表面附近。为了实现这一目标,我们选择了上述城市的一处地基,该地基自 2012 年开始建造,至今仍未完工。所选地基占地约 2000 平方米。样本从七个不同区域采集,每个区域采集三个样本,共计 21 个样本。所选区域是受地下水影响最大的区域,特别是最靠近土壤的区域,如靠近地基边缘或开口的区域。对所有样本进行的抗压强度测试结果表明,抗压强度显著下降。平均而言,测试结果显示抗压强度下降了 30%,这突出表明了复合盐污染地下水对混凝土地基耐久性的重大影响。
{"title":"Assessing the Impact of Composite Salt-Contaminated Groundwater on compressive strength of Concrete Foundations: A Case Study in Basra, Iraq","authors":"Hayder A. O. Al-Deewan, Mohammad Almohammad-albakkar, Hussein Khudhair, Wadi AL-WADI","doi":"10.33899/rengj.2023.141945.1270","DOIUrl":"https://doi.org/10.33899/rengj.2023.141945.1270","url":null,"abstract":"This study aims to investigate the impact of groundwater containing composite salts on the compressive strength of concrete foundations located in the city of Basra in Iraq. The groundwater in this city demonstrates high concentrations of salts, particularly significant amounts of magnesium, sodium, and calcium salts, which are present in close proximity to the soil surface. To accomplish this objective, a foundation in the mentioned city was selected, which has been constructed since 2012 and remains incomplete to this day. The chosen foundation covers an area of approximately 2000 m 2 . Samples were collected from seven distinct regions, with three samples obtained from each region, resulting in a total of 21 samples. The selected regions were those most affected by groundwater, specifically those closest to the soil, such as regions near edges or openings within the foundation. The results of compressive strength tests conducted on all specimens indicated a remarkable decline in compressive strength. On average, the findings revealed a 30% reduction in compressive strength, highlighting the significant impact of composite salt-contaminated groundwater on the durability of concrete foundations.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"102 15","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140089000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simulation of Direct Extrusion Process of Aluminum Alloy Using the Finite Element Method 使用有限元法模拟铝合金的直接挤压工艺
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.143343.1286
zena badrany, Mohammed Abdullah
Due to the intricate die design, the metal flow and stress distribution in the metal extrusion process are quite complex. This study successfully used the commercial finite element code Deform-3D to simulate the stress distribution in the direct hot extrusion of Al-AA7075 rods. The outcomes demonstrate that the ideal die angle reduces the effective stress intensity. The best die angle for the least effective stress is angle 15°, and the best die angle for the least maximum stress is angle 30°. Moreover, the least load is found at an angle of 15°; the load decreases with an increase in the diameter. Further more, careful design of the extrusion dies profile can therefore control and reduce the stresses, which cause a main defect in product structure, supported that it can be used to minimize the amount of in-homogeneity imparted in to the product, and therefore control the product quality.
由于模具设计复杂,金属挤压过程中的金属流动和应力分布相当复杂。本研究使用商用有限元代码 Deform-3D 成功模拟了 Al-AA7075 棒材直接热挤压过程中的应力分布。结果表明,理想的模具角度可降低有效应力强度。有效应力最小的最佳模具角度为 15°,最大应力最小的最佳模具角度为 30°。此外,15°角时的载荷最小;载荷随直径的增大而减小。此外,挤压模具外形的精心设计可以控制和减少造成产品结构主要缺陷的应力,从而最大限度地减少产品的不均匀性,进而控制产品质量。
{"title":"Simulation of Direct Extrusion Process of Aluminum Alloy Using the Finite Element Method","authors":"zena badrany, Mohammed Abdullah","doi":"10.33899/rengj.2023.143343.1286","DOIUrl":"https://doi.org/10.33899/rengj.2023.143343.1286","url":null,"abstract":"Due to the intricate die design, the metal flow and stress distribution in the metal extrusion process are quite complex. This study successfully used the commercial finite element code Deform-3D to simulate the stress distribution in the direct hot extrusion of Al-AA7075 rods. The outcomes demonstrate that the ideal die angle reduces the effective stress intensity. The best die angle for the least effective stress is angle 15°, and the best die angle for the least maximum stress is angle 30°. Moreover, the least load is found at an angle of 15°; the load decreases with an increase in the diameter. Further more, careful design of the extrusion dies profile can therefore control and reduce the stresses, which cause a main defect in product structure, supported that it can be used to minimize the amount of in-homogeneity imparted in to the product, and therefore control the product quality.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":" 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140091603","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design and Miniaturized a High Suppression Stop band Micro strip Low Pass Filter by using Slot Defected Ground Structure for 5G Applications 利用槽式缺陷地层结构为 5G 应用设计并微型化高抑制阻带微带低通滤波器
Pub Date : 2024-03-01 DOI: 10.33899/arej.2024.145273.1311
Ashraf Al-hussein, Saad Luhaib
In this paper, a low-pass filter (LPF) microstrip generalized Chebyshev type defected ground with a high suppression stopband was proposed. The resonators of the suggested filter were implemented using a T-shape microstrip. The filter resonators consist of three main parts. A part of the resonators was used to improve the rejection of the filter in the stopping region, a second part was used to increase the selectivity of the filter, and the last part was used to balance between the two regions. The microstrip LPF filter is designed on a Roger RT/Duroid 5880 substrate with εr=2.2, a thickness of 0.381 mm. 11 th order generalized Chebyshev LPF was simulated using HFSS software. The simulation results were as follows: 2 GHz for the cut-off frequency, insertion loss of 0.55 dB at about 20 dB return loss, and a wide range of stopband suppression below the level of 28 dB from frequency 3.4 GHz to 20 GHz. The LPF selectivity was approximately 37.5 dB/GHz and a small and compact size filter with 0.014λ2g was introduced. The filter matches the specifications required for fifth-generation filters in wireless communications systems.
本文提出了一种具有高抑制阻带的低通滤波器(LPF)微带广义切比雪夫型缺陷地。建议滤波器的谐振器采用 T 型微带。滤波器谐振器由三个主要部分组成。一部分谐振器用于提高滤波器在阻带区域的抑制能力,另一部分用于提高滤波器的选择性,最后一部分用于平衡两个区域。微带 LPF 滤波器是在 Roger RT/Duroid 5880 基板上设计的,基板εr=2.2,厚度为 0.381 毫米。使用 HFSS 软件对 11 阶广义切比雪夫 LPF 进行了仿真。仿真结果如下:截止频率为 2 GHz,插入损耗为 0.55 dB,回波损耗约为 20 dB,在 3.4 GHz 至 20 GHz 频率范围内,阻带抑制在 28 dB 以下。LPF 的选择性约为 37.5 dB/GHz,并采用了 0.014λ2g 的小型紧凑滤波器。该滤波器符合无线通信系统中第五代滤波器的规格要求。
{"title":"Design and Miniaturized a High Suppression Stop band Micro strip Low Pass Filter by using Slot Defected Ground Structure for 5G Applications","authors":"Ashraf Al-hussein, Saad Luhaib","doi":"10.33899/arej.2024.145273.1311","DOIUrl":"https://doi.org/10.33899/arej.2024.145273.1311","url":null,"abstract":"In this paper, a low-pass filter (LPF) microstrip generalized Chebyshev type defected ground with a high suppression stopband was proposed. The resonators of the suggested filter were implemented using a T-shape microstrip. The filter resonators consist of three main parts. A part of the resonators was used to improve the rejection of the filter in the stopping region, a second part was used to increase the selectivity of the filter, and the last part was used to balance between the two regions. The microstrip LPF filter is designed on a Roger RT/Duroid 5880 substrate with εr=2.2, a thickness of 0.381 mm. 11 th order generalized Chebyshev LPF was simulated using HFSS software. The simulation results were as follows: 2 GHz for the cut-off frequency, insertion loss of 0.55 dB at about 20 dB return loss, and a wide range of stopband suppression below the level of 28 dB from frequency 3.4 GHz to 20 GHz. The LPF selectivity was approximately 37.5 dB/GHz and a small and compact size filter with 0.014λ2g was introduced. The filter matches the specifications required for fifth-generation filters in wireless communications systems.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"118 28","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140089728","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Water Absorption of Foamed Concrete using Recycled Aggregate Derived from Construction and Demolition Waste 使用从建筑和拆除废料中提取的再生骨料的发泡混凝土吸水率
Pub Date : 2024-03-01 DOI: 10.33899/rengj.2023.143673.1291
Zinah A. Shareef, Sofyan Kashmolah, Omar Abdulkareem
Foam concrete (FC) is a type of lightweight concrete that has had many voides added by the foaming agent. This paper investigates the possibility of using two types of construction and demolition waste (CDWs), including thermostone blocks and ceramic tiles, as a partial replacement of sand in foam concrete to test the water absorption performance of foamed concrete. Twenty-one samples with three volume-replacement rates of sand for each waste type were explored (25, 50, and 75%). The effect of these various proportions on workability, fresh density, hardened density, and water absorption, it has been established. The results showed that the workability decreased with increasing replacement, and the density of hardened foam concrete increased. As for water absorption, it decreased at all replacement ratios as a result of filling the pores inside the foam concrete and thus increasing the bulk density. Which, in turn, reduces the permeability of foam concrete. The maximum redection in absorption and permeable voids was in the replacement of 75% of thermostone and ceramic waste powders, where the redection was 20.68% in absorption and 29.2% in permeable voids for thermostone replacement, the absorption value was 15.96%, and the permeable voids were 38.28% for ceramic.
泡沫混凝土(FC)是一种由发泡剂添加了许多空隙的轻质混凝土。本文研究了在泡沫混凝土中使用两种建筑和拆除废物(CDW)(包括保温石块和瓷砖)部分替代砂的可能性,以测试发泡混凝土的吸水性能。我们对 21 个样品进行了研究,每种废物的沙子体积替代率分别为 25%、50% 和 75%。确定了这些不同比例对工作性、新拌密度、硬化密度和吸水性的影响。结果表明,随着掺量的增加,工作性降低,而硬化泡沫混凝土的密度增加。至于吸水率,由于泡沫混凝土内部的孔隙被填充,从而增加了体积密度,因此在所有替代率下吸水率都有所下降。这反过来又降低了泡沫混凝土的渗透性。吸水率和渗透性空隙的最大改善是在替代 75%的热稳定剂和陶瓷废粉时,热稳定剂的吸水率和渗透性空隙的改善分别为 20.68%和 29.2%,陶瓷的吸水率为 15.96%,渗透性空隙为 38.28%。
{"title":"Water Absorption of Foamed Concrete using Recycled Aggregate Derived from Construction and Demolition Waste","authors":"Zinah A. Shareef, Sofyan Kashmolah, Omar Abdulkareem","doi":"10.33899/rengj.2023.143673.1291","DOIUrl":"https://doi.org/10.33899/rengj.2023.143673.1291","url":null,"abstract":"Foam concrete (FC) is a type of lightweight concrete that has had many voides added by the foaming agent. This paper investigates the possibility of using two types of construction and demolition waste (CDWs), including thermostone blocks and ceramic tiles, as a partial replacement of sand in foam concrete to test the water absorption performance of foamed concrete. Twenty-one samples with three volume-replacement rates of sand for each waste type were explored (25, 50, and 75%). The effect of these various proportions on workability, fresh density, hardened density, and water absorption, it has been established. The results showed that the workability decreased with increasing replacement, and the density of hardened foam concrete increased. As for water absorption, it decreased at all replacement ratios as a result of filling the pores inside the foam concrete and thus increasing the bulk density. Which, in turn, reduces the permeability of foam concrete. The maximum redection in absorption and permeable voids was in the replacement of 75% of thermostone and ceramic waste powders, where the redection was 20.68% in absorption and 29.2% in permeable voids for thermostone replacement, the absorption value was 15.96%, and the permeable voids were 38.28% for ceramic.","PeriodicalId":400548,"journal":{"name":"Al-Rafidain Engineering Journal (AREJ)","volume":"115 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140088078","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Al-Rafidain Engineering Journal (AREJ)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1