首页 > 最新文献

Journal of the Korean Ophthalmological Society最新文献

英文 中文
A Case of Transient Posterior Capsular Opacity After Intravitreal Bevacizumab Injection 玻璃体内注射贝伐珠单抗后出现一过性后囊翳的病例
Pub Date : 2023-11-15 DOI: 10.3341/jkos.2023.64.11.1115
Hyun Young Park, Do Young Kim, Jong Yun Yang, H. Kim
Purpose: We are reporting a case of transient posterior capsular opacity after intravitreal Bevacizumab (Avastin®, Roche Pharma Schweis AG, Zurich, Switzerland) injection in a phakic patient.Case summary: A 34-year-old man visited our clinic with sudden blurred vision in his left eye one day after the intravitreal injection for central serous chorioretinopathy. His visual acuity was 1.0 before the injection and decreased to 0.1 at the presentation. On slit-lamp examination, a snow-flake appearance opacity was noted behind the posterior capsule. No newly appearing lesion was presented on fundus exam, so topical antibiotics and steroid eyedrops were continued. One week after the injection, the visual acuity improved to 1.0 and posterior capsular opacity remained but decreased. Five weeks after the injection, the posterior capsular opacity resolved. Fundus exam revealed improved but persistent subretinal fluid, so he overwent another intravitreal injection. The posterior capsular opacity did not recur for seven months.Conclusions: Iatrogenic lens damage or the turbidity formed by medication can cause a posterior capsular opacity after intravitreal injection. If structural damage is uncertain, close monitoring is needed and ultimately, cataract surgery may be required for chronic crystalline lens opacity.
病例摘要:一名 34 岁的男性患者因中心性浆液性脉络膜视网膜病变接受玻璃体内注射治疗一天后,左眼突然出现视力模糊而到我院就诊。注射前他的视力为 1.0,就诊时视力降至 0.1。裂隙灯检查发现,后囊后方出现雪花状混浊。眼底检查未发现新的病变,因此继续使用局部抗生素和类固醇眼药水。注射一周后,视力提高到 1.0,后囊混浊依然存在,但有所减轻。注射五周后,后囊膜翳消退。眼底检查显示视网膜下积液有所改善,但仍持续存在,因此他再次接受了玻璃体内注射。七个月后,后囊膜翳没有复发:结论:先天性晶状体损伤或药物形成的浑浊可导致玻璃体内注射后出现后囊膜混浊。如果结构性损伤不确定,则需要密切监测,最终可能需要对慢性晶状体混浊进行白内障手术。
{"title":"A Case of Transient Posterior Capsular Opacity After Intravitreal Bevacizumab Injection","authors":"Hyun Young Park, Do Young Kim, Jong Yun Yang, H. Kim","doi":"10.3341/jkos.2023.64.11.1115","DOIUrl":"https://doi.org/10.3341/jkos.2023.64.11.1115","url":null,"abstract":"Purpose: We are reporting a case of transient posterior capsular opacity after intravitreal Bevacizumab (Avastin®, Roche Pharma Schweis AG, Zurich, Switzerland) injection in a phakic patient.Case summary: A 34-year-old man visited our clinic with sudden blurred vision in his left eye one day after the intravitreal injection for central serous chorioretinopathy. His visual acuity was 1.0 before the injection and decreased to 0.1 at the presentation. On slit-lamp examination, a snow-flake appearance opacity was noted behind the posterior capsule. No newly appearing lesion was presented on fundus exam, so topical antibiotics and steroid eyedrops were continued. One week after the injection, the visual acuity improved to 1.0 and posterior capsular opacity remained but decreased. Five weeks after the injection, the posterior capsular opacity resolved. Fundus exam revealed improved but persistent subretinal fluid, so he overwent another intravitreal injection. The posterior capsular opacity did not recur for seven months.Conclusions: Iatrogenic lens damage or the turbidity formed by medication can cause a posterior capsular opacity after intravitreal injection. If structural damage is uncertain, close monitoring is needed and ultimately, cataract surgery may be required for chronic crystalline lens opacity.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"4 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139273515","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Comparison of Long-term Surgical Results for Sensory Exotropia and Comitant Exotropia 感觉性外斜视与合并性外斜视的长期手术效果比较
Pub Date : 2023-11-15 DOI: 10.3341/jkos.2023.64.11.1071
Jung Hye Shin, Seong-Joon Kim, Jae Ho Jung
Purpose: To compare the long-term surgical outcomes of patients with sensory and concomitant exotropia and to define the factors associated with successful surgical outcomes in those with sensory exotropia.Methods: The medical records of patients with sensory exotropia who underwent operations and were followed-up for at least 2 years were retrospectively reviewed. We enrolled patients exhibiting only best-corrected visual acuities ≤ 20/100 of the operated eyes. Surgical success was defined as a final distance deviation < 10 prism diopters (PD) with the eye in the primary position. Twenty-eight patients operated upon to treat sensory exotropia and 28 who underwent operations to treat concomitant exotropia who did not differ in terms of the gaze deviation angle were matched in terms of age, sex, and the preoperative distance and near distributions; their surgical outcomes were compared. Factors affecting such outcomes were identified using a multivariate Cox’s proportional hazards model.Results: The mean follow-up times were 91.7 ± 45.8 months in the sensory and 42.6 ± 27.7 months in the concomitant exotropia groups. The cumulative probabilities of surgical success 2 years after surgery were 74.5% in the sensory and 74.4% in the intermittent exotropia groups, thus not significantly different (p = 0.988). The Cox’s proportional hazard model showed that a greater difference between the preoperative distant and near deviations was associated with recurrence (p = 0.091).Conclusions: The long-term surgical outcomes of patients with sensory and concomitant exotropia were comparable. A high-level near-distance disparity increased the risk of recurrence.
目的:比较感觉性和伴发性外斜患者的长期手术疗效,并确定与感觉性外斜患者手术成功相关的因素:方法: 我们对接受手术并随访至少两年的感觉性外斜患者的病历进行了回顾性审查。我们招募的患者中,只有手术眼的最佳矫正视力低于 20/100。手术成功的定义是眼球处于主视位时,最终距离偏差小于 10 个棱镜度数 (PD)。在年龄、性别、术前远近分布方面没有差异的28名接受感觉性外斜视手术的患者和28名接受并发症外斜视手术的患者进行了配对,并对他们的手术结果进行了比较。使用多变量考克斯比例危险模型确定了影响这些结果的因素:感觉组的平均随访时间为 91.7 ± 45.8 个月,合并外斜视组的平均随访时间为 42.6 ± 27.7 个月。感觉组和间歇性外斜视组术后2年手术成功的累积概率分别为74.5%和74.4%,因此没有显著差异(p = 0.988)。Cox比例危险模型显示,术前远近偏差差异越大,复发率越高(p = 0.091):结论:感觉性外斜和合并外斜患者的长期手术疗效相当。结论:感觉性外斜和并发性外斜患者的长期手术疗效相当,但近距离偏差过大会增加复发风险。
{"title":"The Comparison of Long-term Surgical Results for Sensory Exotropia and Comitant Exotropia","authors":"Jung Hye Shin, Seong-Joon Kim, Jae Ho Jung","doi":"10.3341/jkos.2023.64.11.1071","DOIUrl":"https://doi.org/10.3341/jkos.2023.64.11.1071","url":null,"abstract":"Purpose: To compare the long-term surgical outcomes of patients with sensory and concomitant exotropia and to define the factors associated with successful surgical outcomes in those with sensory exotropia.Methods: The medical records of patients with sensory exotropia who underwent operations and were followed-up for at least 2 years were retrospectively reviewed. We enrolled patients exhibiting only best-corrected visual acuities ≤ 20/100 of the operated eyes. Surgical success was defined as a final distance deviation < 10 prism diopters (PD) with the eye in the primary position. Twenty-eight patients operated upon to treat sensory exotropia and 28 who underwent operations to treat concomitant exotropia who did not differ in terms of the gaze deviation angle were matched in terms of age, sex, and the preoperative distance and near distributions; their surgical outcomes were compared. Factors affecting such outcomes were identified using a multivariate Cox’s proportional hazards model.Results: The mean follow-up times were 91.7 ± 45.8 months in the sensory and 42.6 ± 27.7 months in the concomitant exotropia groups. The cumulative probabilities of surgical success 2 years after surgery were 74.5% in the sensory and 74.4% in the intermittent exotropia groups, thus not significantly different (p = 0.988). The Cox’s proportional hazard model showed that a greater difference between the preoperative distant and near deviations was associated with recurrence (p = 0.091).Conclusions: The long-term surgical outcomes of patients with sensory and concomitant exotropia were comparable. A high-level near-distance disparity increased the risk of recurrence.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"47 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139273661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Changes in Macular Thickness and Microvasculature in Koreans with Early Parkinson’s Disease 韩国早期帕金森病患者黄斑厚度和微血管的变化
Pub Date : 2023-11-15 DOI: 10.3341/jkos.2023.64.11.1055
Leeha Kwon, Y. Cho, Seong-Jae Kim, I. Chung, Woong-Sun Yoo
Purpose: To investigate the thickness of the nerve fiber layer-ganglion cell inner plexiform layer (NFL-GCIPL) complex and microvascular macular changes in Korean patients with early Parkinson’s disease using optical coherence tomography (OCT) and OCT angiography (OCTA).Methods: Forty-three eyes of 22 patients with early Parkinson’s disease were included. A control group of 20 patients (40 eyes) was also recruited. The thickness of the NFL-GCIPL macular complex was measured using OCT, and the densities of the superficial and deep macular retinal vessels were evaluated via OCTA in all subjects.Results: The NFL-GCIPL thicknesses of the superior, inferior, temporal, and nasal sectors were 94.70 ± 9.35, 93.32 ± 9.16, 90.18 ± 6.32, and 93.11 ± 8.75 μm in the control group and 92.05 ± 4.96, 91.32 ± 7.48, 84.74 ± 6.82, and 91.32 ± 7.47 μm in the Parkinson’s disease group, respectively; all thicknesses were significantly greater in the control group. The superficial and deep retinal vessel densities did not differ between the two groups.Conclusions: Neurodegenerative macular changes are more obvious than microvascular changes in patients with early Parkinson’s disease. Such neurodegenerative changes should be further evaluated in future cohort studies.
目的:使用光学相干断层扫描(OCT)和 OCT 血管造影术(OCTA)研究韩国早期帕金森病患者的神经纤维层-神经节细胞内丛状层(NFL-GCIPL)复合体厚度和黄斑微血管变化:方法:纳入22名早期帕金森病患者的43只眼睛。方法:纳入 22 名早期帕金森病患者的 43 只眼睛,同时纳入 20 名患者(40 只眼睛)的对照组。用 OCT 测量了 NFL-GCIPL 黄斑复合体的厚度,并通过 OCTA 评估了所有受试者黄斑视网膜浅层和深层血管的密度:对照组上、下、颞和鼻区的 NFL-GCIPL 厚度分别为 94.70 ± 9.35、93.32 ± 9.16、90.18 ± 6.32 和 93.11 ± 8.75 μm,帕金森病组的 NFL-GCIPL 厚度分别为 92.05 ± 4.96、91.32 ± 7.48、84.74 ± 6.82 和 91.32 ± 7.47 μm;对照组的所有厚度均明显高于帕金森病组。两组视网膜浅层和深层血管密度没有差异:结论:早期帕金森病患者黄斑部的神经退行性变化比微血管变化更明显。今后的队列研究应进一步评估这些神经退行性变化。
{"title":"Changes in Macular Thickness and Microvasculature in Koreans with Early Parkinson’s Disease","authors":"Leeha Kwon, Y. Cho, Seong-Jae Kim, I. Chung, Woong-Sun Yoo","doi":"10.3341/jkos.2023.64.11.1055","DOIUrl":"https://doi.org/10.3341/jkos.2023.64.11.1055","url":null,"abstract":"Purpose: To investigate the thickness of the nerve fiber layer-ganglion cell inner plexiform layer (NFL-GCIPL) complex and microvascular macular changes in Korean patients with early Parkinson’s disease using optical coherence tomography (OCT) and OCT angiography (OCTA).Methods: Forty-three eyes of 22 patients with early Parkinson’s disease were included. A control group of 20 patients (40 eyes) was also recruited. The thickness of the NFL-GCIPL macular complex was measured using OCT, and the densities of the superficial and deep macular retinal vessels were evaluated via OCTA in all subjects.Results: The NFL-GCIPL thicknesses of the superior, inferior, temporal, and nasal sectors were 94.70 ± 9.35, 93.32 ± 9.16, 90.18 ± 6.32, and 93.11 ± 8.75 μm in the control group and 92.05 ± 4.96, 91.32 ± 7.48, 84.74 ± 6.82, and 91.32 ± 7.47 μm in the Parkinson’s disease group, respectively; all thicknesses were significantly greater in the control group. The superficial and deep retinal vessel densities did not differ between the two groups.Conclusions: Neurodegenerative macular changes are more obvious than microvascular changes in patients with early Parkinson’s disease. Such neurodegenerative changes should be further evaluated in future cohort studies.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"E-29 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139274323","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Changes in the Ocular Biometric Measurements of Korean Children with Myopia and Hyperopia 韩国近视和远视儿童眼部生物测量指标的变化
Pub Date : 2023-11-15 DOI: 10.3341/jkos.2023.64.11.1063
Ji Eon Kang, Sin Hae Park, Sun Young Shin
Purpose: To document changes in the optical coherence biometry data over 1 year of Korean children aged 6 to 9 years with myopia and hyperopia.Methods: We used fluorescein angiography to retrospectively study changes in refractive errors over 1 year in 60 children who visited our hospital between December 2019 and June 2022. The IOL master 700 platform was used to derive axial length, corneal curvature (the K value), central corneal thickness, anterior chamber depth, lens thickness, and the white-to-white size at 1-year intervals. The Mann-Whitney and Wilcoxon signed-ranked tests were used to compare the values. A p-value < 0.05 was taken to indicate a significant difference.Results: The mean ages of hyperopic and myopic children were 6.27 ± 0.87 and 6.93 ± 0.87 years at initial presentation. Significant 1-year changes in axial length, anterior depth, and lens thickness were apparent. The mean corneal curvature, and central corneal and lens thicknesses were significantly higher in hyperopic than myopic children but the axial length and anterior chamber depth were significantly greater in myopic children. However, after 1 year, the lens thicknesses did not significantly differ between the two groups.Conclusions: Over 1 year of early life, changes in the mean corneal curvature and lens thickness were significant in hyperopic children and changes in the axial length and anterior depth were significant in myopic children. Thus, the eye growth pattern may differ between hyperopic and myopic children.
目的:记录韩国6至9岁近视和远视儿童一年内光学相干生物测量数据的变化:我们使用荧光素血管造影术回顾性研究了2019年12月至2022年6月期间在我院就诊的60名儿童1年内屈光不正的变化。使用 IOL master 700 平台得出每隔 1 年的轴长、角膜曲率(K 值)、角膜中央厚度、前房深度、晶状体厚度和白-白大小。采用 Mann-Whitney 和 Wilcoxon 符号排序检验来比较这些数值。P值小于0.05表示差异显著:远视和近视儿童初次发病时的平均年龄分别为 6.27 ± 0.87 岁和 6.93 ± 0.87 岁。轴长、前深度和晶状体厚度在1年内有明显变化。远视儿童的平均角膜曲率、角膜中央厚度和晶状体厚度明显高于近视儿童,但近视儿童的轴长和前房深度明显大于远视儿童。然而,1 年后,两组儿童的晶状体厚度没有明显差异:结论:在幼儿期的 1 年中,远视儿童的平均角膜曲率和晶状体厚度变化显著,而近视儿童的眼轴长度和前房深度变化显著。因此,远视和近视儿童的眼球发育模式可能有所不同。
{"title":"Changes in the Ocular Biometric Measurements of Korean Children with Myopia and Hyperopia","authors":"Ji Eon Kang, Sin Hae Park, Sun Young Shin","doi":"10.3341/jkos.2023.64.11.1063","DOIUrl":"https://doi.org/10.3341/jkos.2023.64.11.1063","url":null,"abstract":"Purpose: To document changes in the optical coherence biometry data over 1 year of Korean children aged 6 to 9 years with myopia and hyperopia.Methods: We used fluorescein angiography to retrospectively study changes in refractive errors over 1 year in 60 children who visited our hospital between December 2019 and June 2022. The IOL master 700 platform was used to derive axial length, corneal curvature (the K value), central corneal thickness, anterior chamber depth, lens thickness, and the white-to-white size at 1-year intervals. The Mann-Whitney and Wilcoxon signed-ranked tests were used to compare the values. A p-value < 0.05 was taken to indicate a significant difference.Results: The mean ages of hyperopic and myopic children were 6.27 ± 0.87 and 6.93 ± 0.87 years at initial presentation. Significant 1-year changes in axial length, anterior depth, and lens thickness were apparent. The mean corneal curvature, and central corneal and lens thicknesses were significantly higher in hyperopic than myopic children but the axial length and anterior chamber depth were significantly greater in myopic children. However, after 1 year, the lens thicknesses did not significantly differ between the two groups.Conclusions: Over 1 year of early life, changes in the mean corneal curvature and lens thickness were significant in hyperopic children and changes in the axial length and anterior depth were significant in myopic children. Thus, the eye growth pattern may differ between hyperopic and myopic children.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"46 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139271196","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Validation and Reliability of the Cataract-related Visual Function Questionnaire (CVFQ) 白内障相关视觉功能问卷(CVFQ)的验证与可靠性
Pub Date : 2023-11-15 DOI: 10.3341/jkos.2023.64.11.1030
Eun Jin Koh, Jong Min Lee, D. Lim, D. Kang, Juhee Cho, Min kyung Song, In Kwon Chung, H. Choi, Ji Woong Chang, Jong Hyun Lee, Tae-Young Chung, Young Sub Eom, Y. Chun, So Hyang Chung, Eun Chul Kim, J. Hyon, Do Hyung Lee
Purpose: To evaluate the reliability and validity of the Cataract-related Visual Function Questionnaire (CVFQ).Methods: A prospective cross-sectional study of 141 cataract patients was conducted from March 2022 to June 2022. The questionnaire was created based on a literature review and advice from an expert panel. This study determined its construct validity, criterion validity, internal consistency, and test-retest reliability.Results: The CVFQ consists of 15 items distributed among five categories: overall visual quality, overall visual function, distance vision, near vision, and glare. In the exploratory factor analysis of validity, the first three principal components explained 77.8% of the variance. The p-values in the Spearman correlation test comparing the pre- and postoperative total CVFQ score and best-corrected visual acuity (BCVA) were 0.006 and 0.004, respectively. In the reliability analysis, Cronbach’s alpha was > 0.9 for internal consistency and the p-values of each subcategory were all significant in the analysis of test-retest reliability.Conclusions: Our results indicate that the CVFQ is useful for measuring the visual quality and visual function of cataract patients in Korea.
目的:评估白内障相关视觉功能问卷(CVFQ)的可靠性和有效性:从 2022 年 3 月到 2022 年 6 月,对 141 名白内障患者进行了前瞻性横断面研究。问卷是根据文献综述和专家小组的建议制作的。该研究确定了问卷的构建效度、标准效度、内部一致性和重测信度:CVFQ由15个项目组成,分布在五个类别中:整体视觉质量、整体视觉功能、远视力、近视力和眩光。在有效性探索性因子分析中,前三个主成分解释了 77.8% 的方差。比较术前和术后 CVFQ 总分与最佳矫正视力(BCVA)的 Spearman 相关性检验的 p 值分别为 0.006 和 0.004。在信度分析中,Cronbach's alpha的内部一致性大于0.9,在测试-再测信度分析中,每个子类别的P值均显著:我们的研究结果表明,CVFQ 可以用于测量韩国白内障患者的视觉质量和视觉功能。
{"title":"Validation and Reliability of the Cataract-related Visual Function Questionnaire (CVFQ)","authors":"Eun Jin Koh, Jong Min Lee, D. Lim, D. Kang, Juhee Cho, Min kyung Song, In Kwon Chung, H. Choi, Ji Woong Chang, Jong Hyun Lee, Tae-Young Chung, Young Sub Eom, Y. Chun, So Hyang Chung, Eun Chul Kim, J. Hyon, Do Hyung Lee","doi":"10.3341/jkos.2023.64.11.1030","DOIUrl":"https://doi.org/10.3341/jkos.2023.64.11.1030","url":null,"abstract":"Purpose: To evaluate the reliability and validity of the Cataract-related Visual Function Questionnaire (CVFQ).Methods: A prospective cross-sectional study of 141 cataract patients was conducted from March 2022 to June 2022. The questionnaire was created based on a literature review and advice from an expert panel. This study determined its construct validity, criterion validity, internal consistency, and test-retest reliability.Results: The CVFQ consists of 15 items distributed among five categories: overall visual quality, overall visual function, distance vision, near vision, and glare. In the exploratory factor analysis of validity, the first three principal components explained 77.8% of the variance. The p-values in the Spearman correlation test comparing the pre- and postoperative total CVFQ score and best-corrected visual acuity (BCVA) were 0.006 and 0.004, respectively. In the reliability analysis, Cronbach’s alpha was > 0.9 for internal consistency and the p-values of each subcategory were all significant in the analysis of test-retest reliability.Conclusions: Our results indicate that the CVFQ is useful for measuring the visual quality and visual function of cataract patients in Korea.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"13 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139271722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Journal of the Korean Ophthalmological Society
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1