首页 > 最新文献

European journal of intensive care medicine最新文献

英文 中文
Bradycardia and cardiac arrest during tracheal suction--mechanisms in tetraplegic patients. 气管吸吸期间心动过缓和心脏骤停——四肢瘫痪患者的机制。
Pub Date : 1976-01-01 DOI: 10.1007/BF00624607
C J Mathias

The cardiovascular responses to tracheal suction were observed in 4 consecutive recently-injured tetraplegics with physiologically complete cervical spinal cord transections (C3-5) who were in spinal shock and needed artificial ventilation. In all 4 patients tracheal suction induced bradycardia and in 2 patients even cardiac arrest. The bradycardia occurred when the patients were hypoxic, and was prevented by the addition of oxygen to inspired air, or, if this was inadequate, by the administration of atropine. Two of the patients were agains studied several months later, after return of isolated spinal cord activity and spontaneous breathing. In both patients tracheal suction then caused tachycardia and increased respiratory effort. It is concluded that: 1. Tetraplegics with high cervical spinal cord transections who are in spinal shock and unable to breathe spontaneously are prone to bradycardia and cardiac arrest during tracheal suction. This is more likely to occur when they are hypoxic. 2. The bradycardia appears to be due to a vago-vagal reflex for both afferent and efferent limbs of the arc are in the vagus nerve. A number of factors play a part, including (I) absent sympathetic activity; (II) airway receptor stimulation; (III) hypoxia and (IV) the inability to breathe spontaneously (The pulmonary (inflation) vagal reflex which would normally oppose the cardio-inhibition caused by (II) and (III) is absent). 3. The bradycardia in response to tracheal suction can be prevented by adequate oxygenation, or if this cannot be achieved, by repeated atropine.

观察了连续4例颈脊髓生理性完全横断(C3-5)的近期损伤四肢瘫痪患者发生脊髓休克,需要人工通气时,对气管吸引的心血管反应。4例患者均因气管吸吸引起心动过缓,2例患者甚至发生心脏骤停。当患者缺氧时发生心动过缓,并通过向吸入空气中添加氧气来预防,如果这不够,则通过给予阿托品来预防。几个月后,在脊髓恢复独立活动和自主呼吸后,对其中两名患者进行了再次研究。在这两例患者中,气管吸引引起心动过速和呼吸力增加。研究结果表明:1。颈脊髓高度横断的四肢瘫痪患者在脊髓休克和不能自主呼吸时,在气管吸吸时容易出现心动过缓和心脏骤停。这在他们缺氧时更容易发生。2. 心动过缓似乎是由于迷走神经中弧线的传入肢和传出肢的迷走反射。有许多因素起作用,包括:(1)缺乏交感神经活动;(II)气道受体刺激;(III)缺氧和(IV)不能自主呼吸(肺(膨胀)迷走反射通常会反对(II)和(III)引起的心脏抑制)。3.气管吸吸引起的心动过缓可通过充氧来预防,如果充氧不能达到,可反复使用阿托品。
{"title":"Bradycardia and cardiac arrest during tracheal suction--mechanisms in tetraplegic patients.","authors":"C J Mathias","doi":"10.1007/BF00624607","DOIUrl":"https://doi.org/10.1007/BF00624607","url":null,"abstract":"<p><p>The cardiovascular responses to tracheal suction were observed in 4 consecutive recently-injured tetraplegics with physiologically complete cervical spinal cord transections (C3-5) who were in spinal shock and needed artificial ventilation. In all 4 patients tracheal suction induced bradycardia and in 2 patients even cardiac arrest. The bradycardia occurred when the patients were hypoxic, and was prevented by the addition of oxygen to inspired air, or, if this was inadequate, by the administration of atropine. Two of the patients were agains studied several months later, after return of isolated spinal cord activity and spontaneous breathing. In both patients tracheal suction then caused tachycardia and increased respiratory effort. It is concluded that: 1. Tetraplegics with high cervical spinal cord transections who are in spinal shock and unable to breathe spontaneously are prone to bradycardia and cardiac arrest during tracheal suction. This is more likely to occur when they are hypoxic. 2. The bradycardia appears to be due to a vago-vagal reflex for both afferent and efferent limbs of the arc are in the vagus nerve. A number of factors play a part, including (I) absent sympathetic activity; (II) airway receptor stimulation; (III) hypoxia and (IV) the inability to breathe spontaneously (The pulmonary (inflation) vagal reflex which would normally oppose the cardio-inhibition caused by (II) and (III) is absent). 3. The bradycardia in response to tracheal suction can be prevented by adequate oxygenation, or if this cannot be achieved, by repeated atropine.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"2 4","pages":"147-56"},"PeriodicalIF":0.0,"publicationDate":"1976-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624607","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"11983793","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 50
Transcutaneous pO2 monitoring in anaesthesia. 麻醉中经皮pO2监测。
Pub Date : 1976-01-01 DOI: 10.1007/BF00571894
R Dennhardt, M Fricke, S Mahal, A Huch, R Huch

In 23 patients 18 to 73 years old transcutaneous PO2, relative local perfusion and cardiorespirogram during induction and end stage of anaesthesia were monitored. This method allows continuous sufficiently exact estimation of PaO2. The comparison between tcPO2 and corresponding blood gas analysis from arterial samples showed a good correlation of r=0.94. Thus continuous tcPO2 registration enables quick diagnosis of hypoxia and its therapy.

对23例18 ~ 73岁经皮PO2患者,监测麻醉诱导和麻醉终末期的局部相对灌注和心肺功能。这种方法允许对PaO2进行连续的、足够精确的估计。动脉血中tcPO2与相应血气分析的相关性为r=0.94。因此,连续的tcPO2登记可以快速诊断和治疗缺氧。
{"title":"Transcutaneous pO2 monitoring in anaesthesia.","authors":"R Dennhardt,&nbsp;M Fricke,&nbsp;S Mahal,&nbsp;A Huch,&nbsp;R Huch","doi":"10.1007/BF00571894","DOIUrl":"https://doi.org/10.1007/BF00571894","url":null,"abstract":"<p><p>In 23 patients 18 to 73 years old transcutaneous PO2, relative local perfusion and cardiorespirogram during induction and end stage of anaesthesia were monitored. This method allows continuous sufficiently exact estimation of PaO2. The comparison between tcPO2 and corresponding blood gas analysis from arterial samples showed a good correlation of r=0.94. Thus continuous tcPO2 registration enables quick diagnosis of hypoxia and its therapy.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"2 1","pages":"29-33"},"PeriodicalIF":0.0,"publicationDate":"1976-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00571894","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12137779","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
The effect of respiration on the monitoring of stroke volume and cardiac output by the electrical impedance technique. 呼吸对电阻抗技术监测搏量和心输出量的影响。
Pub Date : 1976-01-01 DOI: 10.1007/BF00571889
J Endresen, D W Hill

In six volunteers (5 male, 1 female) it has been shown that normal respiration made no statistical difference to the estimates of the mean stroke volume and the mean cardiac output as determined by the electrical impedance method of Kubicek et al, (1966). The coefficient of variation was usually increased by respiration. The use of those stroke volumes which occur only at end-expiration was not shown to yield a greater reproducibility with 3 other male volunteers. In the female subject it was found that the use of a digital averager triggered from the preceding R-wave of the ECG gave values for the mean stroke volume and cardiac output which were always lower than the conventional mean values obtained from a number of strokes. The expense of either of these approaches does not appear to be justified as a means of compensating for the effects of normal respiration on the impedance dZ/dt waveform.

在6名志愿者(5名男性,1名女性)中,研究表明,正常呼吸对Kubicek等人(1966)的电阻抗法确定的平均搏气量和平均心输出量的估计没有统计学差异。变异系数通常因呼吸作用而增大。使用这些只发生在临终时的中风量,在其他3名男性志愿者身上没有显示出更大的再现性。在女性受试者中,发现使用由ECG的前r波触发的数字平均值给出的平均中风量和心输出量的值总是低于从许多中风中获得的常规平均值。这两种方法的费用似乎都不能作为补偿正常呼吸对阻抗dZ/dt波形影响的一种手段。
{"title":"The effect of respiration on the monitoring of stroke volume and cardiac output by the electrical impedance technique.","authors":"J Endresen,&nbsp;D W Hill","doi":"10.1007/BF00571889","DOIUrl":"https://doi.org/10.1007/BF00571889","url":null,"abstract":"<p><p>In six volunteers (5 male, 1 female) it has been shown that normal respiration made no statistical difference to the estimates of the mean stroke volume and the mean cardiac output as determined by the electrical impedance method of Kubicek et al, (1966). The coefficient of variation was usually increased by respiration. The use of those stroke volumes which occur only at end-expiration was not shown to yield a greater reproducibility with 3 other male volunteers. In the female subject it was found that the use of a digital averager triggered from the preceding R-wave of the ECG gave values for the mean stroke volume and cardiac output which were always lower than the conventional mean values obtained from a number of strokes. The expense of either of these approaches does not appear to be justified as a means of compensating for the effects of normal respiration on the impedance dZ/dt waveform.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"2 1","pages":"3-6"},"PeriodicalIF":0.0,"publicationDate":"1976-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00571889","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12137780","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A defibrillatory trolley. 除颤器手推车。
Pub Date : 1976-01-01 DOI: 10.1007/BF00571899
M F Jamieson
{"title":"A defibrillatory trolley.","authors":"M F Jamieson","doi":"10.1007/BF00571899","DOIUrl":"https://doi.org/10.1007/BF00571899","url":null,"abstract":"","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"2 1","pages":"59"},"PeriodicalIF":0.0,"publicationDate":"1976-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00571899","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12137783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Multivariate data analysis based on a computerized patient monitoring system. 基于计算机化病人监护系统的多变量数据分析。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624438
E Freye, R Eberhard

Multivariate time series data in post-operative patients (respiratory and cardiovascular) are compared to reference groups. Using this technique under the program control of a computerized patient monitoring system (IBM 1800) various classes in the respiratory and cardiovascular spectrum can define the co-ordinate system in hyperspace. The patient in crisis is recognised by his deviation from normal rates of change of the variable set, as well as by the time trajectories of recovery in the hyperspace.

将术后患者(呼吸和心血管)的多变量时间序列数据与对照组进行比较。在计算机化病人监测系统(IBM 1800)的程序控制下使用该技术,呼吸和心血管频谱中的各种类别可以定义超空间中的坐标系。危机中的病人是通过他对变量集正常变化率的偏离以及超空间中恢复的时间轨迹来识别的。
{"title":"Multivariate data analysis based on a computerized patient monitoring system.","authors":"E Freye,&nbsp;R Eberhard","doi":"10.1007/BF00624438","DOIUrl":"https://doi.org/10.1007/BF00624438","url":null,"abstract":"<p><p>Multivariate time series data in post-operative patients (respiratory and cardiovascular) are compared to reference groups. Using this technique under the program control of a computerized patient monitoring system (IBM 1800) various classes in the respiratory and cardiovascular spectrum can define the co-ordinate system in hyperspace. The patient in crisis is recognised by his deviation from normal rates of change of the variable set, as well as by the time trajectories of recovery in the hyperspace.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"193-7"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624438","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"11964250","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of a proposed index of myocardial blood flow in dogs. 犬心肌血流量指标的评价。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624434
H J Testa, B R Pullan, P A Tealey, P F Johnson, D J Rowlands

An index of myocardial blood flow developed from studies with a computer and a mechanical circulatory model has been investigated in 18 dogs. An intravenous injection of 131I is used with external scintillation detection over the left ventricle and the lung. The index is given by the ratio of the half time of the downslope of the curve recorded from the left ventricle to that of the curve recorded from the lung. This index has been compared with that suggested by Mena et al in which the left ventricular half time is compared with the half time of the brain curve. The effect on these indices and on the clearance of 133Xe of clamping the anterior descending branch of the left coronary artery has been observed. Statistically significant differences in both indices and in Xenon clearance were seen to be induced by coronary artery clamping but there was overlap between the clamped and unclamped values. The method used for coronary clamping also affected the results.

用计算机和机械循环模型研究了18只狗的心肌血流量指数。静脉注射131I,左心室和肺外闪烁检测。该指标由左心室记录的曲线下坡的一半时间与肺记录的曲线下坡的一半时间之比给出。该指数已与Mena等人提出的左心室半时间与脑曲线半时间的比较进行了比较。观察了夹持左冠状动脉前降支对上述指标及133Xe清除率的影响。冠状动脉夹持诱导的两项指标和氙气清除率均有统计学差异,但夹持和未夹持值存在重叠。冠状动脉夹紧的方法也影响结果。
{"title":"Evaluation of a proposed index of myocardial blood flow in dogs.","authors":"H J Testa,&nbsp;B R Pullan,&nbsp;P A Tealey,&nbsp;P F Johnson,&nbsp;D J Rowlands","doi":"10.1007/BF00624434","DOIUrl":"https://doi.org/10.1007/BF00624434","url":null,"abstract":"<p><p>An index of myocardial blood flow developed from studies with a computer and a mechanical circulatory model has been investigated in 18 dogs. An intravenous injection of 131I is used with external scintillation detection over the left ventricle and the lung. The index is given by the ratio of the half time of the downslope of the curve recorded from the left ventricle to that of the curve recorded from the lung. This index has been compared with that suggested by Mena et al in which the left ventricular half time is compared with the half time of the brain curve. The effect on these indices and on the clearance of 133Xe of clamping the anterior descending branch of the left coronary artery has been observed. Statistically significant differences in both indices and in Xenon clearance were seen to be induced by coronary artery clamping but there was overlap between the clamped and unclamped values. The method used for coronary clamping also affected the results.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"163-73"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624434","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12395277","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A computerized neurosurgical intensive care system. 计算机神经外科重症监护系统。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624437
J Szewczykowski, J Korsak-Sliwka, A Kunicki, S Sliwka, P Dytko

A specialized neurosurgical data acquisition and processing system was developed and applied in practice to monitor some 60 patients after head injury or neurosurgical operations. At first the system allowed off-line operation, and the experiences thus gained made it possible to implement the system in its present form for real-time on-line patient monitoring. The algorithms prepared in our laboratory allow rapid and concise presentation of results and have proved their usefulness in clinical practice. The main parameters of interest in neurosurgery are intracranial pressure (ICP) and the volume of cerebrospinal fluid (CSF) drained from one of the lateral ventricles. Examples of statistical analysis of both these variables, and their presentation in the form of tables, diagrams and histograms are given.

开发了一套神经外科数据采集与处理系统,并将其应用于60例颅脑损伤或神经外科手术后的监测。起初,该系统允许离线操作,由此获得的经验使系统能够以目前的形式实现实时在线患者监测。在我们实验室准备的算法允许快速和简洁的结果呈现,并已证明其在临床实践中的实用性。神经外科的主要参数是颅内压(ICP)和侧脑室排出的脑脊液(CSF)的体积。给出了对这两个变量进行统计分析的例子,并以表格、图表和直方图的形式给出了它们的表示。
{"title":"A computerized neurosurgical intensive care system.","authors":"J Szewczykowski,&nbsp;J Korsak-Sliwka,&nbsp;A Kunicki,&nbsp;S Sliwka,&nbsp;P Dytko","doi":"10.1007/BF00624437","DOIUrl":"https://doi.org/10.1007/BF00624437","url":null,"abstract":"<p><p>A specialized neurosurgical data acquisition and processing system was developed and applied in practice to monitor some 60 patients after head injury or neurosurgical operations. At first the system allowed off-line operation, and the experiences thus gained made it possible to implement the system in its present form for real-time on-line patient monitoring. The algorithms prepared in our laboratory allow rapid and concise presentation of results and have proved their usefulness in clinical practice. The main parameters of interest in neurosurgery are intracranial pressure (ICP) and the volume of cerebrospinal fluid (CSF) drained from one of the lateral ventricles. Examples of statistical analysis of both these variables, and their presentation in the form of tables, diagrams and histograms are given.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"189-92"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624437","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"11964249","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Furosemide, mithramycin, and salmon calcitonin in hypercalcemia. 速尿、米霉素和鲑鱼降钙素在高钙血症中的作用。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624436
J P Filastre, G Humbert, J Leroy, J Maitrot, P Deshayes, M A Canonne

Twenty-nine patients with acute hypercalcemia secondary to carcinoma, myeloma and parathyroid adenoma have been treated with large doses of furosemide, mithramycin, or salmon calcitonin perfusion. With furosemide administration the treatment was successful in 6 of 10 patients. Furosemide was injected intravenously at the rate of 125 mg every 3 hours. With mithramycin perfusion only 2 of 8 patients have a return of the serum calcium levels to normal. With salmon thyrocalcitonin 3 of 10 patients obtained a good result. It can be interesting to suggest the association of furosemide and salmon calcitonin infusion to treat hypercalcemia of myeloma.

29例继发于癌、骨髓瘤和甲状旁腺瘤的急性高钙血症患者采用大剂量速尿、米霉素或鲑鱼降钙素灌注治疗。应用速尿治疗10例患者中6例成功。速尿以每3小时125 mg的速度静脉注射。米霉素灌注后,8例患者中只有2例血钙水平恢复正常。应用鲑鱼甲状腺降钙素治疗10例患者中3例获得良好效果。这可能是有趣的建议联合速尿和鲑鱼降钙素输注治疗骨髓瘤高钙血症。
{"title":"Furosemide, mithramycin, and salmon calcitonin in hypercalcemia.","authors":"J P Filastre,&nbsp;G Humbert,&nbsp;J Leroy,&nbsp;J Maitrot,&nbsp;P Deshayes,&nbsp;M A Canonne","doi":"10.1007/BF00624436","DOIUrl":"https://doi.org/10.1007/BF00624436","url":null,"abstract":"<p><p>Twenty-nine patients with acute hypercalcemia secondary to carcinoma, myeloma and parathyroid adenoma have been treated with large doses of furosemide, mithramycin, or salmon calcitonin perfusion. With furosemide administration the treatment was successful in 6 of 10 patients. Furosemide was injected intravenously at the rate of 125 mg every 3 hours. With mithramycin perfusion only 2 of 8 patients have a return of the serum calcium levels to normal. With salmon thyrocalcitonin 3 of 10 patients obtained a good result. It can be interesting to suggest the association of furosemide and salmon calcitonin infusion to treat hypercalcemia of myeloma.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"185-8"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624436","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"11349689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The changes in blood resistivity with haematocrit and temperature. 血液电阻率随红细胞压积和温度的变化。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624433
S N Mohapatra, D W Hill

The temperature dependence of the resistivity of blood samples with haematocrits from 16 to 52.5% has been investigated over the temperature range of 22 degrees ot 40 degrees C at a frequency of 100 kHz. The resistivity of whole blood increased with an increase in haematocrit and a decrease in temperature. The data fitted the relationship: Pohm-cm=(6.272 Hct + 75.176) - (0.104 Hct + 1.467) tC weree Hct is the percentage haematocrit.

在100 kHz频率下,在22°C至40°C的温度范围内,研究了红细胞比容为16至52.5%的血液样品电阻率的温度依赖性。全血电阻率随红细胞压积的增加和温度的降低而增加。Pohm-cm=(6.272 Hct + 75.176) - (0.104 Hct + 1.467) tC, Hct为红细胞压积百分比。
{"title":"The changes in blood resistivity with haematocrit and temperature.","authors":"S N Mohapatra,&nbsp;D W Hill","doi":"10.1007/BF00624433","DOIUrl":"https://doi.org/10.1007/BF00624433","url":null,"abstract":"<p><p>The temperature dependence of the resistivity of blood samples with haematocrits from 16 to 52.5% has been investigated over the temperature range of 22 degrees ot 40 degrees C at a frequency of 100 kHz. The resistivity of whole blood increased with an increase in haematocrit and a decrease in temperature. The data fitted the relationship: Pohm-cm=(6.272 Hct + 75.176) - (0.104 Hct + 1.467) tC weree Hct is the percentage haematocrit.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"153-62"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624433","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12395274","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 39
A computer model and a mechanical model of the circulation and their use in the evaluation of indices of myocardial blood flow. 循环的计算机模型和力学模型及其在心肌血流指标评价中的应用。
Pub Date : 1975-12-01 DOI: 10.1007/BF00624435
H J Testa, B R Pullan, D J Rowlands

Computer and mechanical models of the circulation have been made to study isotopic techniques of determining indices of myocardial blood flow. Parameters in the program and dimensions in the mechanical model have been scaled to represent the human circulation. Single rapid injections of 131I labelled human serum albumen were given into the venous line of the mechanical model and records obtained from collimated scintillation detectors positioned over the heart, lung and brain. Similar injections and recordings were simulated in the computer model. Two indices of myocardial flow have been studied. The first, described by Mena et al. is the ratio of the half time of the downslope of the left ventricular curve to the half time of the downslope of the brain curve. This index distinguished myocardial flows of 0,5% and 10% of total cardiac output but was also affected by changes in cerebral flow. A new index is proposed in which the half time of the left ventricular curve downslope is related to the half time of the downslope of the lung curve. This index can distinguish myocardial flows of 0,5% and 10% total flow but is not affected by changes in cerebral flow.

建立了循环的计算机模型和力学模型来研究测定心肌血流指标的同位素技术。程序中的参数和机械模型中的尺寸已按比例缩放,以表示人体循环。将131I标记的人血清白蛋白单次快速注射到机械模型的静脉线中,并从位于心、肺和脑上方的准直闪烁检测器获得记录。在计算机模型中模拟了类似的注射和记录。研究了心肌血流的两个指标。第一种是由Mena等人描述的左心室曲线下坡的一半时间与大脑曲线下坡的一半时间之比。该指标区分心肌流量占总心输出量的0.5%、5%和10%,但也受脑流量变化的影响。提出了左心室曲线下坡半时间与肺曲线下坡半时间相关的新指标。该指标可区分总流量0、5%和10%的心肌流量,但不受脑流量变化的影响。
{"title":"A computer model and a mechanical model of the circulation and their use in the evaluation of indices of myocardial blood flow.","authors":"H J Testa,&nbsp;B R Pullan,&nbsp;D J Rowlands","doi":"10.1007/BF00624435","DOIUrl":"https://doi.org/10.1007/BF00624435","url":null,"abstract":"<p><p>Computer and mechanical models of the circulation have been made to study isotopic techniques of determining indices of myocardial blood flow. Parameters in the program and dimensions in the mechanical model have been scaled to represent the human circulation. Single rapid injections of 131I labelled human serum albumen were given into the venous line of the mechanical model and records obtained from collimated scintillation detectors positioned over the heart, lung and brain. Similar injections and recordings were simulated in the computer model. Two indices of myocardial flow have been studied. The first, described by Mena et al. is the ratio of the half time of the downslope of the left ventricular curve to the half time of the downslope of the brain curve. This index distinguished myocardial flows of 0,5% and 10% of total cardiac output but was also affected by changes in cerebral flow. A new index is proposed in which the half time of the left ventricular curve downslope is related to the half time of the downslope of the lung curve. This index can distinguish myocardial flows of 0,5% and 10% total flow but is not affected by changes in cerebral flow.</p>","PeriodicalId":75836,"journal":{"name":"European journal of intensive care medicine","volume":"1 4","pages":"175-83"},"PeriodicalIF":0.0,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF00624435","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12395279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
European journal of intensive care medicine
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1