首页 > 最新文献

Digitale Bilddiagnostik最新文献

英文 中文
[The value of magnetic resonance tomography using gadolinium-DTPA in the diagnosis of the post-lumbar disk surgery syndrome]. [钆- dtpa磁共振断层扫描在腰椎间盘手术后综合征诊断中的价值]。
Pub Date : 1989-03-01
H K Beyer, H Hötzinger, U Oppel, C Tödt

Our results have shown that MR tomography - especially if gadolinium-DTPA is used as a contrast medium - is an excellent method to differentiate between the various possible causes of the post-discotomy syndrome. In particular, it is definitely possible to differentiate between a relapsed hernia of an intervertebral disc and a postoperative development of cicatricial tissue which is practically inevitable. This differentiation is of vital importance to the clinician, because a second operation should be performed only in case of a relapse, whereas cicatricial tissue is best left alone, because no matter how carefully the operation is performed with preparation of the neural structures, even more extensive cicatricial plates are bound to develop. Instability of the vertebral column in the operated disc segment, or other causes of complaints, can be identified via MR equally well if not better than by other means. Hence, the method should be the method of choice in postdiscotomy syndrome, since it facilitates the difficult choice between conservative therapy and reoperation.

我们的研究结果表明,MR断层扫描-特别是如果使用钆- dtpa作为造影剂-是一种很好的方法来区分椎间盘切开术后综合征的各种可能原因。特别是,区分椎间盘复发性疝和瘢痕组织的术后发展是绝对可能的,瘢痕组织的术后发展实际上是不可避免的。这种分化对临床医生来说是至关重要的,因为只有在复发的情况下才应该进行第二次手术,而瘢痕组织最好不要动,因为无论手术如何仔细地准备神经结构,更广泛的瘢痕板必然会形成。手术椎间盘节段的脊柱不稳定或其他原因引起的不适,可以通过MR识别,即使不比其他方法更好。因此,该方法是椎间盘切开术后综合征的首选方法,因为它有助于保守治疗和再手术的艰难选择。
{"title":"[The value of magnetic resonance tomography using gadolinium-DTPA in the diagnosis of the post-lumbar disk surgery syndrome].","authors":"H K Beyer,&nbsp;H Hötzinger,&nbsp;U Oppel,&nbsp;C Tödt","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Our results have shown that MR tomography - especially if gadolinium-DTPA is used as a contrast medium - is an excellent method to differentiate between the various possible causes of the post-discotomy syndrome. In particular, it is definitely possible to differentiate between a relapsed hernia of an intervertebral disc and a postoperative development of cicatricial tissue which is practically inevitable. This differentiation is of vital importance to the clinician, because a second operation should be performed only in case of a relapse, whereas cicatricial tissue is best left alone, because no matter how carefully the operation is performed with preparation of the neural structures, even more extensive cicatricial plates are bound to develop. Instability of the vertebral column in the operated disc segment, or other causes of complaints, can be identified via MR equally well if not better than by other means. Hence, the method should be the method of choice in postdiscotomy syndrome, since it facilitates the difficult choice between conservative therapy and reoperation.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"22-30"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13846569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[A new multislice gradient echo sequence for magnetic resonance tomography of the liver]. [一种新的肝脏磁共振断层扫描多层梯度回波序列]。
Pub Date : 1989-03-01
B Sander, M Laniado, M Langer, R Bittner, R Felix, P Neuhaus

A multislice gradient echo sequence was developed for screening the liver and examined in studies on probands. This sequence is characterized by pronounced T1-weighting and low susceptibility to artifacts as well as a good contrast-to-noise ratio. Examination of the probands yielded suitable parameters for the repetition time, the delay echo, the excitation pulse angle and the number of data acquisitions. The optimized sequence yields, at a repetition time of 306 msec and an echo delay of 12 msec, 18 adjacent slices. With these measurement parameters an excitation pulse angle of 90 degrees was found to be adequate. Four data acquisitions (5.4 minutes measurement time) resulted in an effective reduction of motion artifacts. Compared with the T1-weighted spin echo sequences, the entire liver can be measured in half the time when using the multislice gradient echo sequence.

多层梯度回声序列用于筛选肝脏,并在先证者的研究中进行了检查。该序列的特点是明显的t1加权和对伪影的低敏感性以及良好的对比噪声比。对先证者的检查得出了重复时间、延迟回波、激励脉冲角和数据采集次数的合适参数。优化后的序列在306毫秒的重复时间和12毫秒的回声延迟下产生18个相邻的切片。根据这些测量参数,发现90度的激励脉冲角是足够的。四次数据采集(5.4分钟的测量时间)有效地减少了运动伪影。与t1加权自旋回波序列相比,多层梯度回波序列可在一半的时间内测量整个肝脏。
{"title":"[A new multislice gradient echo sequence for magnetic resonance tomography of the liver].","authors":"B Sander,&nbsp;M Laniado,&nbsp;M Langer,&nbsp;R Bittner,&nbsp;R Felix,&nbsp;P Neuhaus","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A multislice gradient echo sequence was developed for screening the liver and examined in studies on probands. This sequence is characterized by pronounced T1-weighting and low susceptibility to artifacts as well as a good contrast-to-noise ratio. Examination of the probands yielded suitable parameters for the repetition time, the delay echo, the excitation pulse angle and the number of data acquisitions. The optimized sequence yields, at a repetition time of 306 msec and an echo delay of 12 msec, 18 adjacent slices. With these measurement parameters an excitation pulse angle of 90 degrees was found to be adequate. Four data acquisitions (5.4 minutes measurement time) resulted in an effective reduction of motion artifacts. Compared with the T1-weighted spin echo sequences, the entire liver can be measured in half the time when using the multislice gradient echo sequence.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"5-11"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13847767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Technics of secondary reconstruction of planar images from magnetic resonance tomographic 3D data sets]. 磁共振层析三维数据集平面图像二次重建技术。
Pub Date : 1988-12-01
M Skalej, U Klose, K Küper

Description of a method to reconstruct planar images from MRT 3D data sets. These images can be of varying orientation. Reconstruction requires a computer and the control panel of a normal magnetic resonance tomography equipment. Calculation of reconstruction is done in a few minutes. Patients can be examined parallel to this without difficulty. The method yields in a much shorter time than before images with a definitely higher resolution than by the conventional technique.

描述了一种从MRT三维数据集重建平面图像的方法。这些图像可以有不同的方向。重建需要一台计算机和一台普通磁共振断层扫描设备的控制面板。重建计算在几分钟内完成。患者可以毫无困难地与此平行进行检查。该方法在较短的时间内获得比传统技术更高的分辨率的图像。
{"title":"[Technics of secondary reconstruction of planar images from magnetic resonance tomographic 3D data sets].","authors":"M Skalej,&nbsp;U Klose,&nbsp;K Küper","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Description of a method to reconstruct planar images from MRT 3D data sets. These images can be of varying orientation. Reconstruction requires a computer and the control panel of a normal magnetic resonance tomography equipment. Calculation of reconstruction is done in a few minutes. Patients can be examined parallel to this without difficulty. The method yields in a much shorter time than before images with a definitely higher resolution than by the conventional technique.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"168-72"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14338565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[The use of CT in meniscopathy]. CT在半月板病中的应用
Pub Date : 1988-12-01
H Tellkamp, W Klein, G Rosenkranz, K Köhler

The results of CT examination of meniscopathies in 54 patients, most of them competitive athletes, are presented. CT has an overall accuracy of about 90 per cent and can hence be used for diagnosing a lesion of the meniscus with a reasonable amount of safety, while being rapid and avoiding unnecessary exposure to stress. This method, therefore, should be a focal point of the imaging methods and thus be placed between the specialist doctor's findings and possible surgery. The pros and cons of CT compared with other imaging methods are discussed.

本文报道54例运动员半月板病的CT检查结果。CT的总体准确度约为90%,因此可用于诊断半月板病变,具有一定的安全性,同时快速且避免不必要的压力暴露。因此,这种方法应该是成像方法的焦点,因此应该放在专科医生的发现和可能的手术之间。讨论了CT与其他成像方法的优缺点。
{"title":"[The use of CT in meniscopathy].","authors":"H Tellkamp,&nbsp;W Klein,&nbsp;G Rosenkranz,&nbsp;K Köhler","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The results of CT examination of meniscopathies in 54 patients, most of them competitive athletes, are presented. CT has an overall accuracy of about 90 per cent and can hence be used for diagnosing a lesion of the meniscus with a reasonable amount of safety, while being rapid and avoiding unnecessary exposure to stress. This method, therefore, should be a focal point of the imaging methods and thus be placed between the specialist doctor's findings and possible surgery. The pros and cons of CT compared with other imaging methods are discussed.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"180-3"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14338566","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Angiodynography: initial experiences with a new sonographic method]. [血管造影:一种新的超声方法的初步经验]。
Pub Date : 1988-12-01
C Thomas, W Bautz, W Müller-Schauenburg, U Feine

Angiodynography is a further development of Duplex sonography and a new, non-invasive imaging method that places no stress on the patient and enables simultaneous sonomorphological diagnosis of the organs and soft parts as well as their blood supply. Experience to date has shown that the angiodynographic vascularisation pattern is a diagnostic criterion in the clarification of circumscribed thyroid changes. If thyroid findings appear to be unclear, e.g. in case of scintigraphic cold nodes, angiodynography can be used with success as a complementary method. It can also help to classify findings in focal lesions of the liver. Information on functional parameters are supplied for differentiating arterial and venous vascular processes. They are easier to apply, more rapid and more accurate than with Duplex sonography. A drawback is the limited depth of penetration (5 MHz transducer). Angiodynography can be appreciated quickly and easily. It appears to be not only a complement to conventional examination methods but may even replace established diagnostic methods in solving certain problems.

血管造影是双超声的进一步发展,是一种新的非侵入性成像方法,对患者没有压力,能够同时对器官和柔软部位及其血液供应进行声像学诊断。迄今为止的经验表明,血管造影血管化模式是澄清局限性甲状腺病变的诊断标准。如果甲状腺表现不明确,例如在扫描冷结节的情况下,血管造影可以作为一种补充方法成功地使用。它还可以帮助对肝局灶性病变的发现进行分类。功能参数的信息提供了区分动脉和静脉血管过程。它们比双工超声更容易应用,更快速,更准确。缺点是穿透深度有限(5mhz换能器)。血管造影可以快速、方便地进行评价。它似乎不仅是对传统检查方法的补充,而且在解决某些问题时甚至可以取代现有的诊断方法。
{"title":"[Angiodynography: initial experiences with a new sonographic method].","authors":"C Thomas,&nbsp;W Bautz,&nbsp;W Müller-Schauenburg,&nbsp;U Feine","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Angiodynography is a further development of Duplex sonography and a new, non-invasive imaging method that places no stress on the patient and enables simultaneous sonomorphological diagnosis of the organs and soft parts as well as their blood supply. Experience to date has shown that the angiodynographic vascularisation pattern is a diagnostic criterion in the clarification of circumscribed thyroid changes. If thyroid findings appear to be unclear, e.g. in case of scintigraphic cold nodes, angiodynography can be used with success as a complementary method. It can also help to classify findings in focal lesions of the liver. Information on functional parameters are supplied for differentiating arterial and venous vascular processes. They are easier to apply, more rapid and more accurate than with Duplex sonography. A drawback is the limited depth of penetration (5 MHz transducer). Angiodynography can be appreciated quickly and easily. It appears to be not only a complement to conventional examination methods but may even replace established diagnostic methods in solving certain problems.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"152-7"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14193736","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[The scimitar syndrome in computed tomography and intravenous subtraction angiography]. [计算机断层扫描和静脉减影血管造影中的弯刀综合征]。
Pub Date : 1988-12-01
U Lörcher, B Hagen

A case of scimitar syndrome is reported in which the diagnosis was first suggested on chest radiograph. The diagnosis was confirmed by computed tomography (CT) and intravenous digital subtraction angiography (DSA). CT and DSA seem to be able to evaluate the structure and distortion of the lung and the vessels.

本文报告了一个弯刀综合征的病例,其诊断最初是在胸片上提出的。通过计算机断层扫描(CT)和静脉数字减影血管造影(DSA)确诊。CT和DSA似乎能够评估肺和血管的结构和扭曲。
{"title":"[The scimitar syndrome in computed tomography and intravenous subtraction angiography].","authors":"U Lörcher,&nbsp;B Hagen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A case of scimitar syndrome is reported in which the diagnosis was first suggested on chest radiograph. The diagnosis was confirmed by computed tomography (CT) and intravenous digital subtraction angiography (DSA). CT and DSA seem to be able to evaluate the structure and distortion of the lung and the vessels.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"184-7"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14193737","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Digital radiographic image enhancement in bone diagnosis--initial clinical results]. [骨诊断中的数字x线图像增强-初步临床结果]。
Pub Date : 1988-12-01
C Zwicker, M Langer, R Langer, C Wasmuht, R Felix

34 patients with skeletal alterations mostly in the periphery were investigated by digital image intensifier radiography (DIIR). A high resolution image-intensifier system (1024 x 1024 matrix, 40 cm, 28 cm, 14 cm image intensifier, maximal spatial resolution: 3.6 lp/mm) was available. The image quality was diagnostic sufficient in 76% using DIIR. A good or very good image quality of fine-structures was obtained only in 41%. The quality deficits in comparison to conventional radiograms were particularly obvious in investigation of the phalangeals. Logarithmic amplification and software upgrading lead after these first clinical investigations to a better image quality.

采用数字图像增强x线摄影(DIIR)对34例以外周为主的骨骼改变患者进行了研究。高分辨率图像增强系统(1024 × 1024矩阵,40 cm, 28 cm, 14 cm图像增强器,最大空间分辨率:3.6 lp/mm)。使用DIIR, 76%的图像质量诊断是足够的。精细结构图像质量良好或非常好的仅占41%。与常规x线片相比,质量缺陷在调查指骨时尤为明显。在这些首次临床研究之后,对数放大和软件升级导致更好的图像质量。
{"title":"[Digital radiographic image enhancement in bone diagnosis--initial clinical results].","authors":"C Zwicker,&nbsp;M Langer,&nbsp;R Langer,&nbsp;C Wasmuht,&nbsp;R Felix","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>34 patients with skeletal alterations mostly in the periphery were investigated by digital image intensifier radiography (DIIR). A high resolution image-intensifier system (1024 x 1024 matrix, 40 cm, 28 cm, 14 cm image intensifier, maximal spatial resolution: 3.6 lp/mm) was available. The image quality was diagnostic sufficient in 76% using DIIR. A good or very good image quality of fine-structures was obtained only in 41%. The quality deficits in comparison to conventional radiograms were particularly obvious in investigation of the phalangeals. Logarithmic amplification and software upgrading lead after these first clinical investigations to a better image quality.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"147-51"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14338563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Comparative studies of cerebral blood flow measurements and measurements of the size of the corpus callosum in patients with schizophrenia]. [精神分裂症患者脑血流测量和胼胝体大小测量的比较研究]。
Pub Date : 1988-12-01
R Petsch, W Günther, E Moser, H Heller

In this study healthy subjects and schizophrenic patients of the so-called Type I and Type II subgroups were examined in each case with a morphological method to determine the size of the corpus callosum and with a method to measure a physiological functional parameter, namely, the regional cerebral blood flow (rCBF). MR and dynamic single photon emission CT were used (in our case as differential method). The study reveals for the first time classified into subgroups of the disease, scientifically measured differences both in the size of the corpus callosum and in the distribution pattern of the blood flow. Whereas the patients of type I had an enlarged corpus callosum and increased blood flow during the task with which they were confronted, these organs were mainly smaller in size with type II patients without an increase in the global blood flow during the relevant task. The statistical data--averaged over patient groups--show these differences clearly, but due to biological scatter it has so far not been possible to arrive at a diagnosis in individual cases.

在这项研究中,健康受试者和所谓的I型和II型亚组的精神分裂症患者分别用形态学方法确定胼胝体的大小和测量生理功能参数的方法,即区域脑血流量(rCBF)。磁共振和动态单光子发射CT(在我们的情况下是微分方法)。该研究首次揭示了该疾病的亚群,科学地测量了胼胝体大小和血流分布模式的差异。而I型患者在面对任务时胼胝体增大,血流量增加,而II型患者在相关任务时,这些器官主要是体积较小,而总体血流量没有增加。统计数据——对患者群体的平均值——清楚地显示了这些差异,但由于生物学上的分散,迄今为止还不可能对个别病例做出诊断。
{"title":"[Comparative studies of cerebral blood flow measurements and measurements of the size of the corpus callosum in patients with schizophrenia].","authors":"R Petsch,&nbsp;W Günther,&nbsp;E Moser,&nbsp;H Heller","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In this study healthy subjects and schizophrenic patients of the so-called Type I and Type II subgroups were examined in each case with a morphological method to determine the size of the corpus callosum and with a method to measure a physiological functional parameter, namely, the regional cerebral blood flow (rCBF). MR and dynamic single photon emission CT were used (in our case as differential method). The study reveals for the first time classified into subgroups of the disease, scientifically measured differences both in the size of the corpus callosum and in the distribution pattern of the blood flow. Whereas the patients of type I had an enlarged corpus callosum and increased blood flow during the task with which they were confronted, these organs were mainly smaller in size with type II patients without an increase in the global blood flow during the relevant task. The statistical data--averaged over patient groups--show these differences clearly, but due to biological scatter it has so far not been possible to arrive at a diagnosis in individual cases.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"173-9"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14394297","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Diseases of the lymphatic system of the head and neck region. A comparative study of MRI and CT]. 头颈部淋巴系统的疾病。MRI与CT的比较研究[j]。
Pub Date : 1988-12-01
H Schedel, T Vogl, D Hahn, K Mees, F Peer, J Lissner

The diagnostic possibilities of magnetic resonance imaging compared with computed tomography in lymphomas and pathological enlargement of the lymph nodes in the head and neck region are presented. Whereas plain MRI examinations showed the same diagnostic sensitivity as CT, application of the paramagnetic contrast medium Gd-DTPA in 50 of 87 patients clearly increased diagnostic accuracy. Signal intensities of T1- or T2-weighted images before therapy (operation, chemotherapy, radiotherapy) and after administration of Gd-DTPA were enhanced, compared with posttherapeutic and plain examinations. An increase after therapy in two patients signalled a relapse or residual tumour tissue; a decrease in three cases was evaluated as response to therapy. Other differential diagnostic processes such as lipomas, neurinomas, glomus tumours etc. were differentiated with the help of signal intensity curves after administration of contrast media and the use of a gradient echo sequence TR/TE = 30/12 msec with a flip angle of 30 degrees. Differentiation of tissue based on morphological criteria such as homogeneity of tumour tissue or the delineation against surrounding tissue structures showed in the case of Hodgkin's disease and inflammatory diseases mainly homogeneous elements without ring-shaped structure. Non-Hodgkin lymphomas had a predominantly homogeneous structure. In squamous cell carcinomas MR revealed in two cases a ring-shaped enhancement.

磁共振成像与计算机断层扫描在淋巴瘤和病理性肿大的淋巴结在头颈部区域的诊断可能性。尽管MRI平扫显示出与CT相同的诊断敏感性,但87例患者中有50例使用顺磁造影剂Gd-DTPA明显提高了诊断准确性。Gd-DTPA治疗前(手术、化疗、放疗)及给药后T1或t2加权图像信号强度较治疗后及平检增强。治疗后两名患者的增加表明复发或残留肿瘤组织;三个病例的减少被评估为对治疗的反应。其他鉴别诊断过程,如脂肪瘤、神经瘤、血管球瘤等,在给予造影剂和使用梯度回波序列TR/TE = 30/12 msec,翻转角度为30度后,在信号强度曲线的帮助下进行鉴别。基于形态学标准的组织分化,如肿瘤组织的同质性或对周围组织结构的描绘,在霍奇金病和炎症性疾病的情况下,主要是同质元素,没有环状结构。非霍奇金淋巴瘤主要呈均匀结构。2例鳞状细胞癌MR显示环状强化。
{"title":"[Diseases of the lymphatic system of the head and neck region. A comparative study of MRI and CT].","authors":"H Schedel,&nbsp;T Vogl,&nbsp;D Hahn,&nbsp;K Mees,&nbsp;F Peer,&nbsp;J Lissner","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The diagnostic possibilities of magnetic resonance imaging compared with computed tomography in lymphomas and pathological enlargement of the lymph nodes in the head and neck region are presented. Whereas plain MRI examinations showed the same diagnostic sensitivity as CT, application of the paramagnetic contrast medium Gd-DTPA in 50 of 87 patients clearly increased diagnostic accuracy. Signal intensities of T1- or T2-weighted images before therapy (operation, chemotherapy, radiotherapy) and after administration of Gd-DTPA were enhanced, compared with posttherapeutic and plain examinations. An increase after therapy in two patients signalled a relapse or residual tumour tissue; a decrease in three cases was evaluated as response to therapy. Other differential diagnostic processes such as lipomas, neurinomas, glomus tumours etc. were differentiated with the help of signal intensity curves after administration of contrast media and the use of a gradient echo sequence TR/TE = 30/12 msec with a flip angle of 30 degrees. Differentiation of tissue based on morphological criteria such as homogeneity of tumour tissue or the delineation against surrounding tissue structures showed in the case of Hodgkin's disease and inflammatory diseases mainly homogeneous elements without ring-shaped structure. Non-Hodgkin lymphomas had a predominantly homogeneous structure. In squamous cell carcinomas MR revealed in two cases a ring-shaped enhancement.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 4","pages":"158-67"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14338564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Segmentation of MR tomograms for quantitative volume estimation]. [定量体积估计的MR层析分割]。
Pub Date : 1988-09-01
M Imme, S Palmié, J Langkowski, K H Schmidt, R Maas, M Heller

MR tomography yields better contrasts for soft tissues than other imaging methods. This allows a reliable measurement of the volume of brain structures, in particular for the ventricular system and e. g. structures in hydrocephalic states. Therefore a method is proposed for segmentation and volume estimation of MR tomograms that is implemented via a computer program. This method provides an accurate determination of the volume tested on multiple-slice-images of normal patients and a phantom. The substantial features and possibilities of this program usable for all kinds of structures in MR-tomograms are explained here in detail.

与其他成像方法相比,MR断层扫描对软组织的对比效果更好。这样可以可靠地测量大脑结构的体积,特别是脑室系统和脑积水状态下的结构。因此,提出了一种通过计算机程序实现的核磁共振层析图分割和体积估计方法。这种方法提供了对正常患者和幻影的多片图像进行体积测试的准确测定。在这里详细解释了该程序可用于各种核磁共振层析成像结构的实质性特征和可能性。
{"title":"[Segmentation of MR tomograms for quantitative volume estimation].","authors":"M Imme,&nbsp;S Palmié,&nbsp;J Langkowski,&nbsp;K H Schmidt,&nbsp;R Maas,&nbsp;M Heller","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>MR tomography yields better contrasts for soft tissues than other imaging methods. This allows a reliable measurement of the volume of brain structures, in particular for the ventricular system and e. g. structures in hydrocephalic states. Therefore a method is proposed for segmentation and volume estimation of MR tomograms that is implemented via a computer program. This method provides an accurate determination of the volume tested on multiple-slice-images of normal patients and a phantom. The substantial features and possibilities of this program usable for all kinds of structures in MR-tomograms are explained here in detail.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"8 3","pages":"103-9"},"PeriodicalIF":0.0,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14308992","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Digitale Bilddiagnostik
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1