首页 > 最新文献

World journal of orthodontics最新文献

英文 中文
Tensile bond strength of lingual orthodontic brackets with adhesive systems. 带黏附系统的舌正畸托槽的拉伸粘结强度。
Pub Date : 2010-01-01
Cumhur Tuncer, Çağri Ulusoy

Aim: To study in vitro the bond strength of three adhesive systems on lingual brackets.

Methods: Forty-five extracted human mandibular premolars were randomly divided into three groups of 15 specimens each. All brackets (Stealth lingual brackets) were bonded with Transbond XT Light Cure Adhesive. In group 1, the conventional primer was used; in group 2, Transbond Moisture Insensitive Primer was employed; and in group 3, an antimicrobial self-etching primer (Clearfil Protect Bond) was used.

Results: The highest mean bond strength values were observed when Clearfil Protect Bond (13.54 ± 0.58 MPa) was used and the lowest after applying the conventional Transbond XT primer (6.41 ± 0.43 MPa). The mean bond strength in group 2 was 8.20 ± 0.50 MPa, which was significantly higher than that of group 1.

Conclusion: Besides its antimicrobial effect, Clearfil Protect Bond results in high bond strength values. Therefore, this product might be preferable when bonding lingual brackets.

目的:研究三种粘结体系在牙槽上的体外粘结强度。方法:45颗拔除的人下颌前磨牙随机分为3组,每组15颗。所有托槽(隐式舌托槽)用Transbond XT光固化胶粘接。第1组采用常规引物;第2组采用跨键湿不敏感底漆;第3组采用抗菌自蚀刻引物(Clearfil Protect Bond)。结果:使用Clearfil Protect bond时的平均结合强度值最高(13.54±0.58 MPa),使用常规Transbond XT引物后的平均结合强度值最低(6.41±0.43 MPa)。2组的平均粘结强度为8.20±0.50 MPa,显著高于1组。结论:Clearfil Protect Bond除具有抗菌作用外,还具有较高的结合强度值。因此,本产品在粘接舌托槽时可能更可取。
{"title":"Tensile bond strength of lingual orthodontic brackets with adhesive systems.","authors":"Cumhur Tuncer,&nbsp;Çağri Ulusoy","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To study in vitro the bond strength of three adhesive systems on lingual brackets.</p><p><strong>Methods: </strong>Forty-five extracted human mandibular premolars were randomly divided into three groups of 15 specimens each. All brackets (Stealth lingual brackets) were bonded with Transbond XT Light Cure Adhesive. In group 1, the conventional primer was used; in group 2, Transbond Moisture Insensitive Primer was employed; and in group 3, an antimicrobial self-etching primer (Clearfil Protect Bond) was used.</p><p><strong>Results: </strong>The highest mean bond strength values were observed when Clearfil Protect Bond (13.54 ± 0.58 MPa) was used and the lowest after applying the conventional Transbond XT primer (6.41 ± 0.43 MPa). The mean bond strength in group 2 was 8.20 ± 0.50 MPa, which was significantly higher than that of group 1.</p><p><strong>Conclusion: </strong>Besides its antimicrobial effect, Clearfil Protect Bond results in high bond strength values. Therefore, this product might be preferable when bonding lingual brackets.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"393-7"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29814145","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of MRI on the mechanical properties of stainless steel orthodontic wires. MRI对不锈钢正畸丝力学性能的影响。
Pub Date : 2010-01-01
Morteza Oshagh, Mohammad Rahim Hematian, Shoaleh Shahidi, Negar Feizi, Farnaz Bayani, Lida Pishbin

Aim: To assess whether the forces created by the magnetic resonance imaging (MRI) field cause a deflection of orthodontic stainless steel archwires or a change of their mechanical properties.

Methods: Sixty stainless steel 0.016-inch archwires were divided into three groups of 20 wires each. The control group was as received from the manufacturer, the MRI 1 group had wires attached to brackets on artificial teeth subjected to MRI (1.5 Tesla), and the MRI 2 group had activated T-loops subjected to MRI (1.5 Tesla). The mechanical properties were compared between the control group and MRI 1 group, whereas in the MRI 2 group, the change in the amount of activation was measured. The data were evaluated by repeated measurement analysis with independent and paired t tests.

Results: Tensile strength did not differ significantly between the control group and the MRI 1 group (P=.64). In the MRI 2 group, the mean distance between the vertical loop legs before and after MRI did not differ significantly (P=.53).

Conclusion: The magnetic field did not significantly affect the mechanical properties of the tested stainless steel wires, nor did it change the loop activation.

目的:探讨磁共振成像(MRI)磁场产生的力是否会引起正畸不锈钢弓线的偏转或其机械性能的改变。方法:将60根0.016英寸不锈钢弓丝分为3组,每组20根。对照组按照生产厂家的要求,MRI 1组在假牙托槽上固定金属丝进行MRI(1.5特斯拉),MRI 2组激活t环进行MRI(1.5特斯拉)。比较对照组和MRI 1组的力学性能,并测量MRI 2组的活化量变化。采用独立t检验和配对t检验进行重复测量分析。结果:MRI 1组与对照组抗拉强度差异无统计学意义(P= 0.64)。在MRI 2组中,MRI前后垂直环形腿之间的平均距离无显著差异(P= 0.53)。结论:磁场对被测不锈钢丝的力学性能没有明显影响,也没有改变线圈的活化。
{"title":"Effect of MRI on the mechanical properties of stainless steel orthodontic wires.","authors":"Morteza Oshagh,&nbsp;Mohammad Rahim Hematian,&nbsp;Shoaleh Shahidi,&nbsp;Negar Feizi,&nbsp;Farnaz Bayani,&nbsp;Lida Pishbin","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To assess whether the forces created by the magnetic resonance imaging (MRI) field cause a deflection of orthodontic stainless steel archwires or a change of their mechanical properties.</p><p><strong>Methods: </strong>Sixty stainless steel 0.016-inch archwires were divided into three groups of 20 wires each. The control group was as received from the manufacturer, the MRI 1 group had wires attached to brackets on artificial teeth subjected to MRI (1.5 Tesla), and the MRI 2 group had activated T-loops subjected to MRI (1.5 Tesla). The mechanical properties were compared between the control group and MRI 1 group, whereas in the MRI 2 group, the change in the amount of activation was measured. The data were evaluated by repeated measurement analysis with independent and paired t tests.</p><p><strong>Results: </strong>Tensile strength did not differ significantly between the control group and the MRI 1 group (P=.64). In the MRI 2 group, the mean distance between the vertical loop legs before and after MRI did not differ significantly (P=.53).</p><p><strong>Conclusion: </strong>The magnetic field did not significantly affect the mechanical properties of the tested stainless steel wires, nor did it change the loop activation.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"e72-7"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29814301","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Correlation among chronologic age, skeletal maturity, and dental age. 年龄、骨骼成熟度和牙龄的相关性。
Pub Date : 2010-01-01
Rashna H Sukhia, Mubassar Fida

Aim: To determine the correlation among chronologic age, skeletal maturity, and dental age in reference to both sexes.

Methods: In 380 subjects (147 males and 233 females) between 7 and 17 years of age, skeletal maturity was assessed using the cervical vertebral maturation stages described by Baccetti et al. Dental age was determined using the Demirjian method. The correlation between skeletal maturity and chronologic age on one side and between skeletal maturity and dental age on the other was assessed with Spearman rank correlation coefficients. Pearson correlation coefficients were used to assess the correlation between chronologic and dental age.

Results: For both sexes, significant correlations among chronologic age, skeletal maturity, and dental age were found. The mandibular first premolar had the highest correlation with skeletal maturation in both sexes.

Conclusion: As skeletal maturity and dental age are significantly correlated, tooth development may be used to assess a patient's skeletal maturity at an early age.

目的:探讨男女年龄、骨骼成熟度和牙龄之间的关系。方法:在7 - 17岁的380名受试者(147名男性和233名女性)中,使用Baccetti等人描述的颈椎成熟阶段来评估骨骼成熟度。采用Demirjian法测定牙龄。用Spearman秩相关系数评估一侧骨骼成熟度与年代学年龄的相关性,另一侧骨骼成熟度与牙齿年龄的相关性。Pearson相关系数用于评估年龄与牙龄之间的相关性。结果:在两性中,年龄、骨骼成熟度和牙龄之间存在显著的相关性。下颌骨第一前磨牙与两性骨骼成熟的相关性最高。结论:由于骨骼成熟度与牙龄显著相关,牙齿发育可用于早期评估患者骨骼成熟度。
{"title":"Correlation among chronologic age, skeletal maturity, and dental age.","authors":"Rashna H Sukhia,&nbsp;Mubassar Fida","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To determine the correlation among chronologic age, skeletal maturity, and dental age in reference to both sexes.</p><p><strong>Methods: </strong>In 380 subjects (147 males and 233 females) between 7 and 17 years of age, skeletal maturity was assessed using the cervical vertebral maturation stages described by Baccetti et al. Dental age was determined using the Demirjian method. The correlation between skeletal maturity and chronologic age on one side and between skeletal maturity and dental age on the other was assessed with Spearman rank correlation coefficients. Pearson correlation coefficients were used to assess the correlation between chronologic and dental age.</p><p><strong>Results: </strong>For both sexes, significant correlations among chronologic age, skeletal maturity, and dental age were found. The mandibular first premolar had the highest correlation with skeletal maturation in both sexes.</p><p><strong>Conclusion: </strong>As skeletal maturity and dental age are significantly correlated, tooth development may be used to assess a patient's skeletal maturity at an early age.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"e78-84"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29814302","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Efficiency of the distal screw in the distal movement of maxillary molars. 远端螺钉在上颌磨牙远端运动中的效能。
Pub Date : 2010-01-01
Mauro Cozzani, Francesco Zallio, Luca Lombardo, Antonio Gracco

Aim: Conventionally, noncompliance distal movement of molars relies exclusively on intraoral anchorage. The distal screw, a distal jet appliance supplemented by two paramedian mini-implants, is an innovative alternative. The aim of this study was to evaluate the suitability of this device to move molars bodily and distally.

Methods: The effects of the distal screw were evaluated in a sample of 18 consecutively treated preadolescent and adolescent individuals (nine females and nine males; mean age at the start of treatment, 11.2 years). Two conical mini-implants (length 11.0 mm, diameter 1.5 to 2.2 mm) were placed in the anterior paramedian area of the palate of each patient. The coil springs of the device were activated to deliver a force of 240 cN per side. The dental and skeletal effects were investigated on pre- and posttreatment cephalometric radiographs.

Results: The distal screw produced a Class I occlusion of the first molars by moving them distally 4.7 mm, which is more than conventional appliances can accomplish. Although this took longer than conventional devices (9.1 months), it had the advantage of a roughly 2.1-mm premolar distal movement (ie, no anchorage loss as with traditional techniques).

Conclusions: The distal screw anchored by two palatal mini-implants allows not only translatory molar distal movement, but also distal movement of the maxillary first premolars, thereby avoiding characteristic anchorage loss.

目的:传统上,磨牙不顺应性远端运动完全依赖于口腔内固支。远端螺钉,一个远端喷射装置,辅以两个辅助微型植入物,是一种创新的替代方案。本研究的目的是评估该装置在身体和远端移动磨牙的适用性。方法:对18例连续治疗的青春期前和青春期个体(男女各9例;治疗开始时的平均年龄,11.2岁)。在每位患者的上颚前正中区放置两个锥形微型种植体(长11.0 mm,直径1.5 ~ 2.2 mm)。该装置的螺旋弹簧被激活,以提供每边240 cN的力。在治疗前后的头颅x线片上研究了对牙齿和骨骼的影响。结果:远端螺钉将第一磨牙向远端移动4.7 mm,使第一磨牙达到I级咬合,这是传统矫治器所不能达到的。虽然这比传统设备(9.1个月)花费的时间更长,但它的优点是大约2.1 mm的前磨牙远端移动(即没有传统技术的支抗损失)。结论:两个腭微型种植体的远端螺钉锚定不仅可以使平移磨牙的远端运动,而且可以使上颌第一前磨牙的远端运动,从而避免了特征性的支抗损失。
{"title":"Efficiency of the distal screw in the distal movement of maxillary molars.","authors":"Mauro Cozzani,&nbsp;Francesco Zallio,&nbsp;Luca Lombardo,&nbsp;Antonio Gracco","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>Conventionally, noncompliance distal movement of molars relies exclusively on intraoral anchorage. The distal screw, a distal jet appliance supplemented by two paramedian mini-implants, is an innovative alternative. The aim of this study was to evaluate the suitability of this device to move molars bodily and distally.</p><p><strong>Methods: </strong>The effects of the distal screw were evaluated in a sample of 18 consecutively treated preadolescent and adolescent individuals (nine females and nine males; mean age at the start of treatment, 11.2 years). Two conical mini-implants (length 11.0 mm, diameter 1.5 to 2.2 mm) were placed in the anterior paramedian area of the palate of each patient. The coil springs of the device were activated to deliver a force of 240 cN per side. The dental and skeletal effects were investigated on pre- and posttreatment cephalometric radiographs.</p><p><strong>Results: </strong>The distal screw produced a Class I occlusion of the first molars by moving them distally 4.7 mm, which is more than conventional appliances can accomplish. Although this took longer than conventional devices (9.1 months), it had the advantage of a roughly 2.1-mm premolar distal movement (ie, no anchorage loss as with traditional techniques).</p><p><strong>Conclusions: </strong>The distal screw anchored by two palatal mini-implants allows not only translatory molar distal movement, but also distal movement of the maxillary first premolars, thereby avoiding characteristic anchorage loss.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"341-5"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29814781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of the stability of self-drilling mini-implants for maxillary anchorage under immediate loading. 即刻载荷作用下自钻微型种植体上颌支抗稳定性评价。
Pub Date : 2010-01-01
Abraham B Lifshitz, Mónica Muñoz

Aim: To evaluate the stability of self-drilling mini-implants used for immediate en masse retraction of all anterior teeth.

Methods: Six patients with 12 self-drilling mini-implants (diameter 1.6 mm, length 6.0 mm), which were placed on each side between the maxillary first molar and second premolar, were evaluated. The mini-implants were loaded immediately after placement with a force of 200 cN. Lateral cephalograms were taken upon loading (T1) and after 6 months of retraction (T2). All T1 and T2 radiographs were analyzed by localizing the anterior border of the mini-implant heads. Their vertical displacement was measured in millimeters to the Frankfort plane; the horizontal displacement was measured to a line perpendicular to the Frankfort plane registered at sella.

Results: Analysis of variance revealed a significant difference for the horizontal (P<.05) but not for the vertical pre- and posttreatment position.

Conclusion: Mini-implants provide good anchorage for the retraction of teeth. However, the self-drilling mini-implants used in this study did not remain absolutely stationary like osseointegrated implants. With loading, they moved in the direction of the applied force, but their displacement had no clinical impact.

目的:评价自钻微型种植体用于前牙即刻全部后缩的稳定性。方法:对6例患者在上颌第一磨牙和第二前磨牙之间各侧放置12颗自钻微型种植体(直径1.6 mm,长度6.0 mm)进行评价。微型种植体在放置后立即以200 cN的力加载。在装填时(T1)和牵拉后6个月(T2)拍摄侧位脑电图。通过定位微型植入头的前缘来分析所有T1和T2 x线片。它们与法兰克福平面的垂直位移以毫米为单位测量;水平位移测量到与法兰克福平面垂直的一条线,记录在塞拉。结果:通过方差分析,发现水平(p)侧支抗有显著性差异。结论:微型种植体对牙后缩具有良好的支抗效果。然而,本研究中使用的自钻孔微型种植体并不像骨整合种植体那样保持绝对静止。随着载荷的增加,它们会向施加力的方向移动,但它们的位移对临床没有影响。
{"title":"Evaluation of the stability of self-drilling mini-implants for maxillary anchorage under immediate loading.","authors":"Abraham B Lifshitz,&nbsp;Mónica Muñoz","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To evaluate the stability of self-drilling mini-implants used for immediate en masse retraction of all anterior teeth.</p><p><strong>Methods: </strong>Six patients with 12 self-drilling mini-implants (diameter 1.6 mm, length 6.0 mm), which were placed on each side between the maxillary first molar and second premolar, were evaluated. The mini-implants were loaded immediately after placement with a force of 200 cN. Lateral cephalograms were taken upon loading (T1) and after 6 months of retraction (T2). All T1 and T2 radiographs were analyzed by localizing the anterior border of the mini-implant heads. Their vertical displacement was measured in millimeters to the Frankfort plane; the horizontal displacement was measured to a line perpendicular to the Frankfort plane registered at sella.</p><p><strong>Results: </strong>Analysis of variance revealed a significant difference for the horizontal (P<.05) but not for the vertical pre- and posttreatment position.</p><p><strong>Conclusion: </strong>Mini-implants provide good anchorage for the retraction of teeth. However, the self-drilling mini-implants used in this study did not remain absolutely stationary like osseointegrated implants. With loading, they moved in the direction of the applied force, but their displacement had no clinical impact.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"352-6"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29814783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Efficiency and effectiveness of SureSmile. 效率和效果的SureSmile。
Pub Date : 2010-01-01
Alana K Saxe, Lenore J Louie, James Mah

Aim: To examine the efficiency and effectiveness of the SureSmile process using the standards of the American Board of Orthodontists Objective Grading System (ABO OGS).

Methods: Three diplomates of the American Board of Orthodontics provided study casts of 62 patients whose orthodontic treatment was consecutively completed. Patients treated using the SureSmile process and a conventional approach were anonymized and randomized prior to independent scoring by two ABO OGS-calibrated examiners.

Results: Intra- and interexaminer reliability was consistent in all components with no differences between examiners (r=0.96, P<.001). The ABO OGS score for the SureSmile patients (mean 26.3) was 4.4 points lower (P<.001) than for those treated conventionally (mean 30.7). Furthermore, treatment with the SureSmile process was shorter (14.7 months vs 20.0 months).

Conclusion: The SureSmile process results in a lower mean ABO OGS score and a reduced treatment time than conventional approaches. The approach has great potential to both decrease treatment time and improve quality.

目的:利用美国正畸医师客观分级系统(ABO OGS)的标准来检验SureSmile过程的效率和有效性。方法:对连续完成正畸治疗的62例患者,由美国正畸委员会3名专家提供研究模型。使用SureSmile方法和传统方法治疗的患者在由两名ABO ogs校准检查人员独立评分之前进行匿名和随机化。结果:检查者内部和检查者之间的可靠性在所有组成部分中是一致的,检查者之间没有差异(r=0.96, p)。结论:与传统方法相比,suremile过程导致较低的ABO OGS平均评分和缩短的治疗时间。该方法在缩短治疗时间和提高治疗质量方面具有很大的潜力。
{"title":"Efficiency and effectiveness of SureSmile.","authors":"Alana K Saxe,&nbsp;Lenore J Louie,&nbsp;James Mah","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To examine the efficiency and effectiveness of the SureSmile process using the standards of the American Board of Orthodontists Objective Grading System (ABO OGS).</p><p><strong>Methods: </strong>Three diplomates of the American Board of Orthodontics provided study casts of 62 patients whose orthodontic treatment was consecutively completed. Patients treated using the SureSmile process and a conventional approach were anonymized and randomized prior to independent scoring by two ABO OGS-calibrated examiners.</p><p><strong>Results: </strong>Intra- and interexaminer reliability was consistent in all components with no differences between examiners (r=0.96, P<.001). The ABO OGS score for the SureSmile patients (mean 26.3) was 4.4 points lower (P<.001) than for those treated conventionally (mean 30.7). Furthermore, treatment with the SureSmile process was shorter (14.7 months vs 20.0 months).</p><p><strong>Conclusion: </strong>The SureSmile process results in a lower mean ABO OGS score and a reduced treatment time than conventional approaches. The approach has great potential to both decrease treatment time and improve quality.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 1","pages":"16-22"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"28758333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Editorial: welcome...and farewell. 编辑:欢迎…和告别。
Pub Date : 2010-01-01
Rainer-Reggie Miethke
{"title":"Editorial: welcome...and farewell.","authors":"Rainer-Reggie Miethke","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"319"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30030193","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The use of Cariogram to evaluate caries-risk profiles in orthodontic patients. 牙齿造影评估正畸患者龋齿风险概况。
Pub Date : 2010-01-01
Anas H Al Mulla, Saad Al Kharsa, Heidrun Kjellberg, Dowden Birkhed

This article describes the usefulness of Cariogram software in three orthodontic patients with high-, medium-, and low-risk caries profiles. Caries-related indicators and information needed for the Cariogram model were registered. The prebonding decayed and filled surfaces (DFS) indices for patient 1 (15-year-old girl) and patient 2 (18-year-old woman) were >5, while in patient 3 (15-year-old boy), the DFS index was <2. The data were entered into the interactive Cariogram software, which shows the various caries-related indicators. Patients 1, 2, and 3 had 6%, 58%, and 87%, respectively, actual chance of avoiding new caries. Patient 1 had high lactobacilli and medium mutans streptococci scores and a high caries risk. Patient 2 had a high DFS index and low buffer capacity, resulting in a medium caries risk. Patient 3 had low mutans streptococci and high lactobacilli scores and a low DFS index, resulting in a low caries risk. The Cariogram is available free online and is a useful educational model to illustrate a patient's caries risk.

这篇文章描述了在三个正畸患者的高,中,低风险龋齿的有用性。登记龋齿相关指标和龋齿图模型所需信息。患者1(15岁女孩)和患者2(18岁女性)的粘结前衰减和填充面(DFS)指数>5,而患者3(15岁男孩)的DFS指数>5
{"title":"The use of Cariogram to evaluate caries-risk profiles in orthodontic patients.","authors":"Anas H Al Mulla,&nbsp;Saad Al Kharsa,&nbsp;Heidrun Kjellberg,&nbsp;Dowden Birkhed","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This article describes the usefulness of Cariogram software in three orthodontic patients with high-, medium-, and low-risk caries profiles. Caries-related indicators and information needed for the Cariogram model were registered. The prebonding decayed and filled surfaces (DFS) indices for patient 1 (15-year-old girl) and patient 2 (18-year-old woman) were >5, while in patient 3 (15-year-old boy), the DFS index was <2. The data were entered into the interactive Cariogram software, which shows the various caries-related indicators. Patients 1, 2, and 3 had 6%, 58%, and 87%, respectively, actual chance of avoiding new caries. Patient 1 had high lactobacilli and medium mutans streptococci scores and a high caries risk. Patient 2 had a high DFS index and low buffer capacity, resulting in a medium caries risk. Patient 3 had low mutans streptococci and high lactobacilli scores and a low DFS index, resulting in a low caries risk. The Cariogram is available free online and is a useful educational model to illustrate a patient's caries risk.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 2","pages":"160-7"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29058106","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Class II correction in a growing patient with hyperdivergent growth patterns and severe overjet. II级矫正:生长模式超发散和严重过喷的患者。
Pub Date : 2010-01-01
Jae Hyun Park

In general, the success of Class II treatment depends as much on the skill of the orthodontist as it does on a favorable facial-growth pattern. Lack of sufficient favorable growth during treatment will make it difficult to correct the skeletal malrelationship or significantly improve the facial profile. The case report presents the treatment of a patient with a Class II, Division 1 malocclusion with severe overjet and a hyperdivergent growth pattern.

一般来说,第二类治疗的成功既取决于良好的面部生长模式,也取决于正畸医生的技能。在治疗过程中缺乏足够的有利生长将使纠正骨骼畸形或显着改善面部轮廓变得困难。病例报告提出了一个病人的治疗II类,1科错牙合严重覆盖和超发散生长模式。
{"title":"Class II correction in a growing patient with hyperdivergent growth patterns and severe overjet.","authors":"Jae Hyun Park","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In general, the success of Class II treatment depends as much on the skill of the orthodontist as it does on a favorable facial-growth pattern. Lack of sufficient favorable growth during treatment will make it difficult to correct the skeletal malrelationship or significantly improve the facial profile. The case report presents the treatment of a patient with a Class II, Division 1 malocclusion with severe overjet and a hyperdivergent growth pattern.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 4","pages":"e35-44"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29813814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of the Bolton ratios on 3D dental casts of Brazilians with natural, normal occlusions. 巴西人自然、正常咬合三维牙模的博尔顿比率评价。
Pub Date : 2010-01-01
Renata Pilli Jóias, Leandro Gonçalves Velasco, Marco Antonio Scanavini, André Luis Ribeiro de Miranda, Danilo Furquim Siqueira

Aim: To evaluate the Bolton ratios in Brazilians with natural, normal occlusions.

Methods: Thirty-five dental casts of Brazilian Caucasians with a natural, normal occlusion from the files of the Postgraduate Program in Orthodontics of the Methodist University of São Paulo were scanned in three dimensions. On the scanned images, the greatest mesiodistal distance of each tooth from right first molar to left first molar was measured with Geomagic Studio 5 software. The Bolton ratios were then calculated.

Results: The anterior ratio amounted to 78.66% (SD ± 2.72) and the total ratio to 91.58% (SD ± 2.20).

Conclusion: The anterior, but not the overall, ratio was significantly different from the ratio suggested by Bolton.

目的:评价巴西人自然、正常闭塞的博尔顿比率。方法:对来自圣保罗卫理公会大学正畸研究生课程档案的35例自然正常咬合的巴西高加索人牙模进行三维扫描。在扫描图像上,用Geomagic Studio 5软件测量每颗牙齿从右第一磨牙到左第一磨牙的最大中远端距离。然后计算波顿比率。结果:前路比例为78.66% (SD±2.72),总比例为91.58% (SD±2.20)。结论:前牙比例与Bolton建议的比例有显著性差异,而非整体比例。
{"title":"Evaluation of the Bolton ratios on 3D dental casts of Brazilians with natural, normal occlusions.","authors":"Renata Pilli Jóias,&nbsp;Leandro Gonçalves Velasco,&nbsp;Marco Antonio Scanavini,&nbsp;André Luis Ribeiro de Miranda,&nbsp;Danilo Furquim Siqueira","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Aim: </strong>To evaluate the Bolton ratios in Brazilians with natural, normal occlusions.</p><p><strong>Methods: </strong>Thirty-five dental casts of Brazilian Caucasians with a natural, normal occlusion from the files of the Postgraduate Program in Orthodontics of the Methodist University of São Paulo were scanned in three dimensions. On the scanned images, the greatest mesiodistal distance of each tooth from right first molar to left first molar was measured with Geomagic Studio 5 software. The Bolton ratios were then calculated.</p><p><strong>Results: </strong>The anterior ratio amounted to 78.66% (SD ± 2.72) and the total ratio to 91.58% (SD ± 2.20).</p><p><strong>Conclusion: </strong>The anterior, but not the overall, ratio was significantly different from the ratio suggested by Bolton.</p>","PeriodicalId":87213,"journal":{"name":"World journal of orthodontics","volume":"11 1","pages":"67-70"},"PeriodicalIF":0.0,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"28758259","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
World journal of orthodontics
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1