首页 > 最新文献

The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc最新文献

英文 中文
The impact of variable tint optics (Transitions Gray) on vision-related quality of life in normal volunteers: a randomized clinical comparison in a warm climate. 变色调光学(过渡灰色)对正常志愿者视觉相关生活质量的影响:在温暖气候下的随机临床比较。
T J Pusateri, P T Lavin, C J Baldy, K A Copeland, M Sequiti

Purpose: A randomized crossover comparison of Transitions Gray variable tint optics (VTO) vs clear and fixed-tint lenses was undertaken to evaluate the impact of VTO on vision-related quality of life (VRQOL) in a warm climate.

Methods: Fifty-nine patients were randomized to one of four lens crossover groups: Transitions-->clear; clear-->Transitions; Transitions-->fixed-tint; fixed-tint-->Transitions. Each lens was worn for 30 days. VRQOL was measured using a newly developed and validated questionnaire instrument-the Transitions VRQOL. Changes in visual acuity were assessed by functional exam.

Results: Overall, Transitions was associated with the greatest improvement in VRQOL relative to clear and fixed-tint lenses without compromise in acuity. Transitions proved statistically superior to clear lenses, most notably in vision comfort both indoors and outdoors. Seventy percent of all patients selected Transitions as their primary lens at the end of the study.

Conclusions: Transitions brand VTO offer patients significant and clinically meaningful improvements in VRQOL superior to clear lenses. VRQOL assessments provide clinicians with valuable information above and beyond visual acuity to help optimize lens product selection and enhance patient satisfaction.

目的:采用随机交叉比较过渡灰度可变色调光学(VTO)与透明和固定色调透镜,以评估VTO对温暖气候下视觉相关生活质量(VRQOL)的影响。方法:59例患者随机分为四个晶状体交叉组:过渡->透明;明确——>转换;转换——> fixed-tint;fixed-tint - >转换。每个镜片佩戴30天。VRQOL使用一种新开发并经过验证的问卷工具- Transitions VRQOL进行测量。通过功能检查评估视力变化。结果:总的来说,相对于透明和固定色调的镜片,过渡与VRQOL的最大改善有关,而不影响视力。从统计数据来看,过渡镜头优于透明镜片,尤其是在室内和室外的视觉舒适度方面。在研究结束时,70%的患者选择transition作为他们的主要晶状体。结论:过渡品牌VTO对患者VRQOL的改善显著且具有临床意义,优于透明镜片。VRQOL评估为临床医生提供了超过视力的有价值的信息,以帮助优化镜片产品的选择,提高患者的满意度。
{"title":"The impact of variable tint optics (Transitions Gray) on vision-related quality of life in normal volunteers: a randomized clinical comparison in a warm climate.","authors":"T J Pusateri,&nbsp;P T Lavin,&nbsp;C J Baldy,&nbsp;K A Copeland,&nbsp;M Sequiti","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>A randomized crossover comparison of Transitions Gray variable tint optics (VTO) vs clear and fixed-tint lenses was undertaken to evaluate the impact of VTO on vision-related quality of life (VRQOL) in a warm climate.</p><p><strong>Methods: </strong>Fifty-nine patients were randomized to one of four lens crossover groups: Transitions-->clear; clear-->Transitions; Transitions-->fixed-tint; fixed-tint-->Transitions. Each lens was worn for 30 days. VRQOL was measured using a newly developed and validated questionnaire instrument-the Transitions VRQOL. Changes in visual acuity were assessed by functional exam.</p><p><strong>Results: </strong>Overall, Transitions was associated with the greatest improvement in VRQOL relative to clear and fixed-tint lenses without compromise in acuity. Transitions proved statistically superior to clear lenses, most notably in vision comfort both indoors and outdoors. Seventy percent of all patients selected Transitions as their primary lens at the end of the study.</p><p><strong>Conclusions: </strong>Transitions brand VTO offer patients significant and clinically meaningful improvements in VRQOL superior to clear lenses. VRQOL assessments provide clinicians with valuable information above and beyond visual acuity to help optimize lens product selection and enhance patient satisfaction.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 4","pages":"225-9"},"PeriodicalIF":0.0,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21896857","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of a new system of lens parameter selection and comparison of traditional vs one-step lens care systems for aspheric high-Dk RGP contact lenses. 一种新的非球面高dk RGP隐形眼镜镜片参数选择系统的评价及传统与一步式镜片护理系统的比较。
J de Brabander, J H Kok, R M Nuijts

Purpose: We investigated the value of newly developed systems for parameter selection on the performance of high Dk rigid gas permeable (RGP) contact lenses with a spheric-aspheric design made of Boston Equa material in normal daily wear conditions. A comparison was also made between the safety and efficacy of a traditional care system vs a one-step chemical care system during the follow-up period of 1 year.

Methods: A total of 66 patients were randomly assigned to traditional and newly developed systems for computing the back optical zone radius (BOZR) and the total diameter (TD) of the lenses. Evaluation parameters incorporated assessment of fit, visual acuity, wearing time, comfort, and lens condition.

Results: The traditional method of computing the BOZR, using a method based on flat-K, predicted the BOZR successfully in 83% of the cases. Corneal topometry reached a lower, but not significantly different (P > 0.01) value of 75% correct prediction of BOZR. Analysis of the differences in eccentricity (E) values between quadrants per eye was a significant (P < 0.001) factor in fault predictions in the topometric system. A newly developed guide forTD selection performed, with 90% correct predictions, significantly (P < 0.01) better than a traditional method (72%) based on corneal diameter on supraversion. No significant differences (P > 0.05) were found in the capabilities of care systems (a traditional care system using a surfactant cleaner vs a one-step solution) to keep the lenses in proper condition and without deformation, over the 1 year follow-up period. The final success rate was 85%.

Conclusions: Although high Dk RGP contact lenses can be fit and used with a 85% success rate using advanced systems for determining the BOZR and TD, it remains necessary to evaluate the fit before dispensing high Dk RGP lenses in 15% of the cases. The one-step solution used in this study was a good starting point for lens care. If needed, surfactant cleaning in the traditional care system can be done without the risk of lens deformation.

目的:研究新开发的高Dk刚性透气性(RGP)隐形眼镜参数选择系统在日常佩戴条件下的应用价值。在1年的随访期间,还比较了传统护理系统与一步化学护理系统的安全性和有效性。方法:66例患者随机分为两组,分别使用传统系统和新型系统计算晶状体后视区半径(BOZR)和晶状体总直径(TD)。评估参数包括评估贴合度、视力、佩戴时间、舒适度和晶状体状况。结果:传统的计算BOZR的方法是基于flat-K的方法,预测BOZR的成功率为83%。角膜topometry对BOZR的预测准确率达到75%,但差异无统计学意义(P > 0.01)。分析每只眼象限之间的偏心率(E)值的差异是地形测量系统故障预测的重要因素(P < 0.001)。一种新开发的td选择指南的预测准确率为90%,显著(P < 0.01)优于基于角膜直径的传统方法(72%)。在1年的随访期间,护理系统(使用表面活性剂清洁剂的传统护理系统与一步解决方案的护理系统)保持镜片处于适当状态且不变形的能力无显著差异(P > 0.05)。最终成功率为85%。结论:尽管使用先进的BOZR和TD测定系统,高Dk RGP隐形眼镜的配戴成功率为85%,但仍有15%的病例需要在配戴高Dk RGP隐形眼镜前评估配戴效果。本研究中使用的一步解决方案是晶状体护理的一个良好起点。如果需要,传统护理系统中的表面活性剂清洁可以完成,而不会有晶状体变形的风险。
{"title":"Evaluation of a new system of lens parameter selection and comparison of traditional vs one-step lens care systems for aspheric high-Dk RGP contact lenses.","authors":"J de Brabander,&nbsp;J H Kok,&nbsp;R M Nuijts","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>We investigated the value of newly developed systems for parameter selection on the performance of high Dk rigid gas permeable (RGP) contact lenses with a spheric-aspheric design made of Boston Equa material in normal daily wear conditions. A comparison was also made between the safety and efficacy of a traditional care system vs a one-step chemical care system during the follow-up period of 1 year.</p><p><strong>Methods: </strong>A total of 66 patients were randomly assigned to traditional and newly developed systems for computing the back optical zone radius (BOZR) and the total diameter (TD) of the lenses. Evaluation parameters incorporated assessment of fit, visual acuity, wearing time, comfort, and lens condition.</p><p><strong>Results: </strong>The traditional method of computing the BOZR, using a method based on flat-K, predicted the BOZR successfully in 83% of the cases. Corneal topometry reached a lower, but not significantly different (P > 0.01) value of 75% correct prediction of BOZR. Analysis of the differences in eccentricity (E) values between quadrants per eye was a significant (P < 0.001) factor in fault predictions in the topometric system. A newly developed guide forTD selection performed, with 90% correct predictions, significantly (P < 0.01) better than a traditional method (72%) based on corneal diameter on supraversion. No significant differences (P > 0.05) were found in the capabilities of care systems (a traditional care system using a surfactant cleaner vs a one-step solution) to keep the lenses in proper condition and without deformation, over the 1 year follow-up period. The final success rate was 85%.</p><p><strong>Conclusions: </strong>Although high Dk RGP contact lenses can be fit and used with a 85% success rate using advanced systems for determining the BOZR and TD, it remains necessary to evaluate the fit before dispensing high Dk RGP lenses in 15% of the cases. The one-step solution used in this study was a good starting point for lens care. If needed, surfactant cleaning in the traditional care system can be done without the risk of lens deformation.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 4","pages":"193-9"},"PeriodicalIF":0.0,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21897552","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Contact lens residency training: progress and challenges. 隐形眼镜住院医师培训:进步与挑战。
P C Donshik, M I Freeman
{"title":"Contact lens residency training: progress and challenges.","authors":"P C Donshik,&nbsp;M I Freeman","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 4","pages":"172"},"PeriodicalIF":0.0,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21898921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses. lotrafilcon高dk硅胶晶状体伴球形晶状体后碎片的临床特征。
K Dumbleton, L Jones, R Chalmers, D Williams-Lyn, D Fonn

Purpose: Experience with high Dk silicone hydrogel lenses has revealed post-lens debris, which is characterized by the appearance of spherical, translucent particles referred to as "mucin balls." The objectives of this analysis were to characterize the presence of mucin balls, determine whether any ocular characteristic predicts the development of mucin ball debris, and determine whether there is any association between mucin balls and the ocular response to contact lens wear.

Methods: Ninety-two subjects wore lotrafilcon A lenses on an extended wear basis for up to 30 nights and were followed for 6 months. Mucin balls were graded on a 0 to 4 scale at three visits. Subjective ratings and biomicroscopic appearance were recorded at all visits.

Results: Mucin balls were observed in 70% of subjects at one or more visits, and 29% of subjects at all three visits. There was no change in the mean grade of mucin balls over time. Mucin balls were graded > 1 in 20% of eyes, > 2 in 6% of eyes, and > 3 in 2% of eyes. Subjects who exhibited mucin balls at each clinical visit had significantly steeper keratometry readings along the flatter meridian (44.3 D) than those who never exhibited mucin balls (42.9 D, P < 0.0001). The percentage of subjects who "never" use lubricating drops was higher in the subjects with mucin balls (P = 0.0014). No association was found between mucin ball observation and biomicroscopic appearance, inflammatory responses, or subjective responses.

Conclusions: The presence of mucin balls does not appear to be detrimental to contact lens wear. Eyes with steeper corneal curvature were significantly more likely to present with mucin ball debris, indicating they may be a function of lens fit. Clinical factors that may be modified in order to manage the more severe presentation of mucin balls are the use of lubricating drops and the number of nights extended wear schedule.

目的:使用高Dk硅水凝胶镜片的经验揭示了镜片后的碎片,其特征是球形半透明颗粒的外观,称为“粘蛋白球”。本分析的目的是表征粘蛋白球的存在,确定是否有任何眼部特征可以预测粘蛋白球碎片的发展,以及确定粘蛋白球与眼部对隐形眼镜佩戴的反应之间是否存在关联。方法:92名受试者连续佩戴lotrafilcon A型隐形眼镜30晚,随访6个月。粘蛋白球在三次访问中被分为0到4级。每次就诊均记录主观评分和生物显微外观。结果:70%的受试者在一次或多次就诊时观察到粘蛋白球,29%的受试者在三次就诊时均观察到粘蛋白球。黏液球的平均分级没有随时间变化。粘蛋白球在20%的眼睛中分级为> 1,在6%的眼睛中分级为> 2,在2%的眼睛中分级为> 3。在每次临床就诊时出现粘蛋白球的受试者,其沿平子午线的角化测量读数(44.3 D)明显高于从未出现粘蛋白球的受试者(42.9 D, P < 0.0001)。使用粘蛋白球的受试者中“从不”使用润滑滴剂的百分比更高(P = 0.0014)。黏液球观察与生物显微镜外观、炎症反应或主观反应之间没有关联。结论:黏液球的存在似乎不会对隐形眼镜的佩戴造成损害。角膜曲率较陡的眼睛明显更容易出现粘蛋白球碎片,表明它们可能是晶状体适合的功能。为了处理黏液球更严重的表现,可以修改的临床因素是润滑滴剂的使用和延长佩戴时间的天数。
{"title":"Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses.","authors":"K Dumbleton,&nbsp;L Jones,&nbsp;R Chalmers,&nbsp;D Williams-Lyn,&nbsp;D Fonn","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Experience with high Dk silicone hydrogel lenses has revealed post-lens debris, which is characterized by the appearance of spherical, translucent particles referred to as \"mucin balls.\" The objectives of this analysis were to characterize the presence of mucin balls, determine whether any ocular characteristic predicts the development of mucin ball debris, and determine whether there is any association between mucin balls and the ocular response to contact lens wear.</p><p><strong>Methods: </strong>Ninety-two subjects wore lotrafilcon A lenses on an extended wear basis for up to 30 nights and were followed for 6 months. Mucin balls were graded on a 0 to 4 scale at three visits. Subjective ratings and biomicroscopic appearance were recorded at all visits.</p><p><strong>Results: </strong>Mucin balls were observed in 70% of subjects at one or more visits, and 29% of subjects at all three visits. There was no change in the mean grade of mucin balls over time. Mucin balls were graded > 1 in 20% of eyes, > 2 in 6% of eyes, and > 3 in 2% of eyes. Subjects who exhibited mucin balls at each clinical visit had significantly steeper keratometry readings along the flatter meridian (44.3 D) than those who never exhibited mucin balls (42.9 D, P < 0.0001). The percentage of subjects who \"never\" use lubricating drops was higher in the subjects with mucin balls (P = 0.0014). No association was found between mucin ball observation and biomicroscopic appearance, inflammatory responses, or subjective responses.</p><p><strong>Conclusions: </strong>The presence of mucin balls does not appear to be detrimental to contact lens wear. Eyes with steeper corneal curvature were significantly more likely to present with mucin ball debris, indicating they may be a function of lens fit. Clinical factors that may be modified in order to manage the more severe presentation of mucin balls are the use of lubricating drops and the number of nights extended wear schedule.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 4","pages":"186-92"},"PeriodicalIF":0.0,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21897551","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A comparison of contact lens-related complications in various daily wear modalities. 各种日常佩戴方式下隐形眼镜相关并发症的比较。
J K Suchecki, W H Ehlers, P C Donshik

Purpose: To determine the incidence of contact lens-related complications in various daily wear contact lens modalities.

Methods: The charts of 138 daily wear contact lens patients (35 daily disposable, 34 two week replacement, 34 frequent replacement, and 35 conventional daily wear lens users) were reviewed for subjective and objective contact lens problems. We also looked at two subgroups: first time lens wearers and patients with previous lens-related problems. The rate of lens related complications were calculated as events per person per year (E/P/Y) of lens wear for each year and for the total 3-year study. The percentage of patients in each group who experienced any complication was calculated. We also compared the complication rate for the groups in our current study to the rates calculated for disposable extended wear and conventional extended wear patients from our previous study.

Results: We found that the E/P/Y were significantly lower for daily disposable lens wearers, but no significant differences were noted for all other lens wear modalities. There was a trend in most groups toward decreased numbers of complications in the second and third years of lens wear. Of the 23 individual signs and symptoms that were analyzed, three occurred most frequently among daily disposable lens wearers, two were most common in the 2-week replacement group, four occurred most often in frequent replacement patients, and eight were most frequent in conventional daily lens wearers. (In three categories, there were two groups with ties for the highest rate of occurrence, and two categories with zero rates for all groups.) Most of the observed differences in complication rates for individual signs and symptoms did not reach the level of statistical significance.

Conclusions: Daily disposable lens wearers had the lowest overall complication rate.

目的:了解不同佩戴方式下隐形眼镜相关并发症的发生率。方法:对138例日常配戴隐形眼镜患者(一次性配戴35例,两周配戴34例,频繁配戴34例,常规配戴35例)的主观和客观隐形眼镜问题进行分析。我们还研究了两个亚组:第一次佩戴隐形眼镜和以前有过隐形相关问题的患者。晶状体相关并发症的发生率计算为每年和总共3年的研究中每人每年的晶状体佩戴事件(E/P/Y)。计算每组患者出现并发症的百分比。我们还比较了我们当前研究中各组的并发症发生率与我们之前研究中一次性延长磨损患者和常规延长磨损患者的并发症发生率。结果:我们发现每日佩戴一次性隐形眼镜者的E/P/Y明显较低,但所有其他隐形眼镜佩戴方式没有显著差异。在大多数人群中,在佩戴晶状体的第二年和第三年,并发症的数量有减少的趋势。在分析的23个个体体征和症状中,3个在每日佩戴一次性隐形眼镜的人群中最常见,2个在两周内更换隐形眼镜的人群中最常见,4个在频繁更换隐形眼镜的人群中最常见,8个在常规每日佩戴隐形眼镜的人群中最常见。(在三个类别中,有两个类别的发生率最高,还有两个类别的发生率为零。)大多数观察到的个体体征和症状的并发症发生率差异没有达到统计学意义的水平。结论:每日佩戴一次性隐形眼镜者并发症发生率最低。
{"title":"A comparison of contact lens-related complications in various daily wear modalities.","authors":"J K Suchecki,&nbsp;W H Ehlers,&nbsp;P C Donshik","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To determine the incidence of contact lens-related complications in various daily wear contact lens modalities.</p><p><strong>Methods: </strong>The charts of 138 daily wear contact lens patients (35 daily disposable, 34 two week replacement, 34 frequent replacement, and 35 conventional daily wear lens users) were reviewed for subjective and objective contact lens problems. We also looked at two subgroups: first time lens wearers and patients with previous lens-related problems. The rate of lens related complications were calculated as events per person per year (E/P/Y) of lens wear for each year and for the total 3-year study. The percentage of patients in each group who experienced any complication was calculated. We also compared the complication rate for the groups in our current study to the rates calculated for disposable extended wear and conventional extended wear patients from our previous study.</p><p><strong>Results: </strong>We found that the E/P/Y were significantly lower for daily disposable lens wearers, but no significant differences were noted for all other lens wear modalities. There was a trend in most groups toward decreased numbers of complications in the second and third years of lens wear. Of the 23 individual signs and symptoms that were analyzed, three occurred most frequently among daily disposable lens wearers, two were most common in the 2-week replacement group, four occurred most often in frequent replacement patients, and eight were most frequent in conventional daily lens wearers. (In three categories, there were two groups with ties for the highest rate of occurrence, and two categories with zero rates for all groups.) Most of the observed differences in complication rates for individual signs and symptoms did not reach the level of statistical significance.</p><p><strong>Conclusions: </strong>Daily disposable lens wearers had the lowest overall complication rate.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 4","pages":"204-13"},"PeriodicalIF":0.0,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21897555","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
1-Day Acuvue vs. Focus Dailies: a comparison of comfort, user preference, and incidence of corneal complications. 1-Day Acuvue与Focus daily:舒适度、用户偏好和角膜并发症发生率的比较。
M Inaba

Purpose: Two types of daily disposable soft contact lenses, 1-Day Acuvue (Johnson & Johnson K.K., Japan) and Focus Dailies (CIBA Vision Corp.), were compared for comfort, user preference, and any associated incidence of corneal complications.

Methods: 1-Day Acuvue and Focus Dailies were randomly prescribed for one eye each of 127 contact lens wearers. After 1 week of lens wear, user preference, anterior segment health, and tear film stability on the contact lenses were evaluated.

Results: Group A consisted of 45 subjects who had been wearing 1-Day Acuvue prior to the study and group B consisted of 82 subjects who had been wearing other types of soft contact lenses prior to the study. A statistically significant number of subjects in both group A and group B preferred 1-Day Acuvue. In group A there were significantly fewer corneal complications in the eyes with 1-Day Acuvue than in the eyes with Dailies. However, there was no difference in the incidence of corneal complications in group B.

Conclusions: If Dailies are prescribed for current 1-Day Acuvue wearers, extra care may be required. 1-Day Acuvue lenses could be prescribed successfully for those who previously wore soft contact lenses other than 1-Day Acuvue.

目的:比较两种日常使用的一次性软性隐形眼镜,1-Day Acuvue(强生公司,日本)和Focus Dailies (CIBA Vision Corp.)的舒适度、使用者偏好和任何相关的角膜并发症发生率。方法:对127名隐形眼镜佩戴者随机开具1天锐度和焦点每日处方。佩戴1周后,评估使用者偏好、前节健康状况和隐形眼镜泪膜稳定性。结果:A组45名受试者在研究前一直佩戴1-Day Acuvue, B组82名受试者在研究前一直佩戴其他类型的软性隐形眼镜。A组和B组均有统计学意义的受试者选择1-Day Acuvue。A组1 d acacuvue组的角膜并发症明显少于ddailies组。然而,b组在角膜并发症的发生率上没有差异。结论:如果目前1天的Acuvue佩戴者使用daily,可能需要额外的注意。对于那些以前佩戴过除1-Day Acuvue以外的软性隐形眼镜的人,可以成功处方1-Day Acuvue镜片。
{"title":"1-Day Acuvue vs. Focus Dailies: a comparison of comfort, user preference, and incidence of corneal complications.","authors":"M Inaba","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Two types of daily disposable soft contact lenses, 1-Day Acuvue (Johnson & Johnson K.K., Japan) and Focus Dailies (CIBA Vision Corp.), were compared for comfort, user preference, and any associated incidence of corneal complications.</p><p><strong>Methods: </strong>1-Day Acuvue and Focus Dailies were randomly prescribed for one eye each of 127 contact lens wearers. After 1 week of lens wear, user preference, anterior segment health, and tear film stability on the contact lenses were evaluated.</p><p><strong>Results: </strong>Group A consisted of 45 subjects who had been wearing 1-Day Acuvue prior to the study and group B consisted of 82 subjects who had been wearing other types of soft contact lenses prior to the study. A statistically significant number of subjects in both group A and group B preferred 1-Day Acuvue. In group A there were significantly fewer corneal complications in the eyes with 1-Day Acuvue than in the eyes with Dailies. However, there was no difference in the incidence of corneal complications in group B.</p><p><strong>Conclusions: </strong>If Dailies are prescribed for current 1-Day Acuvue wearers, extra care may be required. 1-Day Acuvue lenses could be prescribed successfully for those who previously wore soft contact lenses other than 1-Day Acuvue.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 3","pages":"141-5"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21785152","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dry eye: towards a new understanding. 干眼:走向新的认识。
P C Donshik
{"title":"Dry eye: towards a new understanding.","authors":"P C Donshik","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 3","pages":"118"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21785147","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fungal keratitis in a soft contact lens wearer. 软性隐形眼镜佩戴者的真菌性角膜炎。
R Foroozan, R C Eagle, E J Cohen

Purpose: To describe a case of fungal keratitis in a soft contact lens wearer.

Methods and results: A 57 year old female, compliant, frequent replacement soft contact lens wearer, with a possible prior history of herpes simplex keratitis, presented with pain and injection of her left eye of four weeks duration. Gram stain of a corneal ulcer of the left eye revealed fungal organisms and cultures grew Fusarium solani. The infiltrate responded to topical and systemic antifungal agents, but a corneal perforation developed which required a therapeutic penetrating keratoplasty.

Conclusions: Fungal infections are a cause of corneal ulcers in contact lens wearers. Despite the use of topical and systemic antifungal agents, fungal ulcers frequently require surgical intervention.

目的:描述一例真菌性角膜炎在软性隐形眼镜佩戴者。方法和结果:57岁女性,依从性强,经常配戴软性隐形眼镜,既往可能有单纯疱疹性角膜炎病史,左眼疼痛和注射持续四周。左眼角膜溃疡的革兰氏染色显示真菌有机体和培养物生长镰刀菌。浸润对局部和全身抗真菌药物有反应,但角膜穿孔发展需要治疗性穿透性角膜移植术。结论:真菌感染是隐形眼镜佩戴者角膜溃疡的原因之一。尽管使用局部和全身抗真菌药物,真菌溃疡经常需要手术干预。
{"title":"Fungal keratitis in a soft contact lens wearer.","authors":"R Foroozan,&nbsp;R C Eagle,&nbsp;E J Cohen","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To describe a case of fungal keratitis in a soft contact lens wearer.</p><p><strong>Methods and results: </strong>A 57 year old female, compliant, frequent replacement soft contact lens wearer, with a possible prior history of herpes simplex keratitis, presented with pain and injection of her left eye of four weeks duration. Gram stain of a corneal ulcer of the left eye revealed fungal organisms and cultures grew Fusarium solani. The infiltrate responded to topical and systemic antifungal agents, but a corneal perforation developed which required a therapeutic penetrating keratoplasty.</p><p><strong>Conclusions: </strong>Fungal infections are a cause of corneal ulcers in contact lens wearers. Despite the use of topical and systemic antifungal agents, fungal ulcers frequently require surgical intervention.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 3","pages":"166-8"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21785019","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Intraoperative PAR corneal topography system (CTS): comparison of its keratometric readings to manual keratometer, auto-keratometer, EyeSys Corneal Analysis system, and slit lamp PAR CTS in healthy eyes. 术中PAR角膜地形图系统(CTS)与健康眼手动角膜地形图仪、自动角膜地形图仪、EyeSys角膜分析系统及裂隙灯PAR CTS的比较
O O Uçakhan, G Sternberg, C Bodian, K Kelliher, P A Asbell

Purpose: To compare the keratometric readings obtained from Intraoperative PAR Corneal Topography System (IOPAR) to those produced by manual keratometer (Mnl-Km), autokeratometer (Auto-Km), EyeSys CAS (EyeSys Corneal Analysis System) and slit lamp PAR CTS in healthy eyes.

Methods: All instruments were calibrated prior to use and only data from the best image obtained was used for statistical analysis. Simulated keratometry readings obtained from the central 3-mm zone of the corneas by IOPAR, including flat (K1) and steep (K2) keratometry readings, average keratometric power (AK), astigmatism (As) (difference between steep and flat keratometry readings) and the axis of the steep meridian (Ax) were compared to those from four other units. The latter units were also compared among themselves. Statistical analysis was done for right and left eyes separately. For each variable, average differences between the measurements taken from pairs of instruments were estimated, with corresponding 95% confidence intervals. The degree of agreement between pairs of instruments on individual measurements was additionally assessed, via the use of "Bland-Altman"-type plots, and estimates of the proportion of cases achieving satisfactory agreement. Additionally, for every variable, the average of the measurements taken from the different instruments were compared.

Results: Forty-five (22 right and 23 left) normal corneas of 26 volunteers were examined. On the average, IOPAR tended to measure K1 higher than slit lamp PAR CTS system. Because K2 measurements taken by the IOPAR were higher than that of all other instruments, the As measurements, on the average, were also higher than that of others, with the exception of the PAR CTS. For the same reasons, the IOPAR produced average AK readings that were higher than those taken by EyeSys CAS and PAR CTS. When the individual measurements taken by the IOPAR were compared with each of the other units, according to the arbitrary designation of satisfactory agreement within +/-0.5 D (for K1, K2, AK, and As) and +/-20 degrees (for Ax), for almost all parameters, proportion of differences that were within the agreement range varied from 0.33 to 0.82, with wide confidence intervals (confidence interval lower limits ranging from 0.20 to 0.61 and upper limits ranging from 0.62 to 0.94).

Conclusions: IOPAR is a clinically useful topographic system, producing qualitative and quantitative data in the operating environment that, in normal corneas, on the average, matches those produced by the other units in the clinic. When individually analyzed, its keratometric measurements may show greater variations with respect to other units. Further studies with multiple examiners, in corneas with high or irregular astigmatism are required to establish its reproducibility and efficacy.

目的:比较术中PAR角膜地形图系统(IOPAR)与手动角膜比目仪(mml - km)、自动角膜比目仪(Auto-Km)、eyeesys角膜分析系统(eyeesys角膜分析系统)和裂隙灯PAR CTS在健康眼的角膜比目仪读数。方法:所有仪器在使用前均进行校准,仅使用获得的最佳图像数据进行统计分析。利用IOPAR在角膜中心3mm区域获得的模拟角膜度数,包括平(K1)和陡(K2)角膜度数、平均角膜度数(AK)、散光(As)(陡与平角膜度数之差)和陡子午线轴(Ax),与其他4个设备进行比较。后两个单位之间也进行了比较。分别对右眼和左眼进行统计分析。对于每个变量,估计从成对仪器中获得的测量值之间的平均差异,具有相应的95%置信区间。另外,通过使用“Bland-Altman”型图,评估仪器对个别测量的一致程度,并估计达到满意一致的病例比例。此外,对于每个变量,从不同的仪器测量的平均值进行了比较。结果:对26名志愿者的45个正常角膜(22个右角膜,23个左角膜)进行了检查。平均而言,IOPAR系统测量的K1高于裂隙灯PAR CTS系统。由于IOPAR的K2测量值高于所有其他仪器,因此除了PAR CTS外,平均而言,As测量值也高于其他仪器。出于同样的原因,IOPAR产生的平均AK读数高于eyeesys CAS和PAR CTS的读数。当IOPAR与其他各单位的测量结果进行比较时,根据任意指定的在+/-0.5 D (K1, K2, AK和As)和+/-20度(Ax)范围内的满意一致性,对于几乎所有参数,在一致性范围内的差异比例从0.33到0.82不等,具有很宽的置信区间(置信区间下限从0.20到0.61,上限从0.62到0.94)。结论:IOPAR是一种临床上有用的地形系统,在正常角膜的操作环境中产生定性和定量数据,平均而言,与临床其他单位产生的数据相匹配。当单独分析时,其角膜测量值可能显示出与其他单位相比更大的变化。在高度散光或不规则散光的角膜中,需要多名检查者进行进一步的研究,以确定其重复性和有效性。
{"title":"Intraoperative PAR corneal topography system (CTS): comparison of its keratometric readings to manual keratometer, auto-keratometer, EyeSys Corneal Analysis system, and slit lamp PAR CTS in healthy eyes.","authors":"O O Uçakhan,&nbsp;G Sternberg,&nbsp;C Bodian,&nbsp;K Kelliher,&nbsp;P A Asbell","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the keratometric readings obtained from Intraoperative PAR Corneal Topography System (IOPAR) to those produced by manual keratometer (Mnl-Km), autokeratometer (Auto-Km), EyeSys CAS (EyeSys Corneal Analysis System) and slit lamp PAR CTS in healthy eyes.</p><p><strong>Methods: </strong>All instruments were calibrated prior to use and only data from the best image obtained was used for statistical analysis. Simulated keratometry readings obtained from the central 3-mm zone of the corneas by IOPAR, including flat (K1) and steep (K2) keratometry readings, average keratometric power (AK), astigmatism (As) (difference between steep and flat keratometry readings) and the axis of the steep meridian (Ax) were compared to those from four other units. The latter units were also compared among themselves. Statistical analysis was done for right and left eyes separately. For each variable, average differences between the measurements taken from pairs of instruments were estimated, with corresponding 95% confidence intervals. The degree of agreement between pairs of instruments on individual measurements was additionally assessed, via the use of \"Bland-Altman\"-type plots, and estimates of the proportion of cases achieving satisfactory agreement. Additionally, for every variable, the average of the measurements taken from the different instruments were compared.</p><p><strong>Results: </strong>Forty-five (22 right and 23 left) normal corneas of 26 volunteers were examined. On the average, IOPAR tended to measure K1 higher than slit lamp PAR CTS system. Because K2 measurements taken by the IOPAR were higher than that of all other instruments, the As measurements, on the average, were also higher than that of others, with the exception of the PAR CTS. For the same reasons, the IOPAR produced average AK readings that were higher than those taken by EyeSys CAS and PAR CTS. When the individual measurements taken by the IOPAR were compared with each of the other units, according to the arbitrary designation of satisfactory agreement within +/-0.5 D (for K1, K2, AK, and As) and +/-20 degrees (for Ax), for almost all parameters, proportion of differences that were within the agreement range varied from 0.33 to 0.82, with wide confidence intervals (confidence interval lower limits ranging from 0.20 to 0.61 and upper limits ranging from 0.62 to 0.94).</p><p><strong>Conclusions: </strong>IOPAR is a clinically useful topographic system, producing qualitative and quantitative data in the operating environment that, in normal corneas, on the average, matches those produced by the other units in the clinic. When individually analyzed, its keratometric measurements may show greater variations with respect to other units. Further studies with multiple examiners, in corneas with high or irregular astigmatism are required to establish its reproducibility and efficacy.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 3","pages":"151-8"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21785017","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Why the eye becomes dry: a cornea and lacrimal gland feedback model. 为什么眼睛会变干:一个角膜和泪腺反馈模型。
W D Mathers

Purpose: Many explanations have been offered for why a large segment of the population develops dry eye. The purpose of this paper is to describe a new unifying theory of dry eye that incorporates all of these causes.

Methods: Data from the Department of Ophthalmology, University of Iowa Hospitals and Clinics was analyzed from 520 patients with dry eye, blepharitis and other conditions to assess the relationship between dry eye and blepharitis. This data was reviewed in terms of the relationship between dry eye, menopause, and aging. Also examined in detail were many of the proposed causes for dry eye in the literature.

Results: A close relationship between corneal damage and lacrimal gland function is hypothesized. Not only does decreased lacrimal gland output damage the ocular surface, but also damage to the corneal surface creates a negative feedback loop and damage to the lacrimal gland. There are probably several mechanisms by which this feedback occurs. One mechanism results from interruption or damage to the sensory corneal nerves. Damage to the nerves within the lacrimal gland may be another mechanism. Alteration of growth factor levels in the lacrimal gland, which occurs following corneal damage, represents another possible mechanism. Contact lenses and corneal refractive surgery are additional elements that may create negative feedback to the lacrimal gland.

Conclusion: The ocular surface and the lacrimal gland functions as a tightly integrated unit. Dry eye conditions damage the ocular surface and this in turn leads to further damage to the lacrimal gland.

目的:对于为什么大部分人会患上干眼症,有很多解释。本文的目的是描述一个新的干眼症的统一理论,包括所有这些原因。方法:分析爱荷华大学附属医院及诊所眼科520例干眼、眼睑炎等疾病患者的资料,探讨干眼与眼睑炎的关系。这些数据在干眼症、更年期和衰老之间的关系方面进行了审查。还详细检查了文献中提出的许多干眼症的原因。结果:推测角膜损伤与泪腺功能密切相关。泪腺输出量的减少不仅会损伤眼表,而且对角膜表面的损伤也会产生负反馈循环,对泪腺造成损伤。可能有几种机制可以产生这种反馈。一种机制是由于角膜感觉神经的中断或损伤。对泪腺内神经的损伤可能是另一种机制。泪腺中生长因子水平的改变,发生在角膜损伤之后,代表了另一种可能的机制。隐形眼镜和角膜屈光手术是可能对泪腺产生负面反馈的额外因素。结论:眼表与泪腺是一个紧密结合的整体。干眼症会损害眼表,进而导致泪腺进一步受损。
{"title":"Why the eye becomes dry: a cornea and lacrimal gland feedback model.","authors":"W D Mathers","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Many explanations have been offered for why a large segment of the population develops dry eye. The purpose of this paper is to describe a new unifying theory of dry eye that incorporates all of these causes.</p><p><strong>Methods: </strong>Data from the Department of Ophthalmology, University of Iowa Hospitals and Clinics was analyzed from 520 patients with dry eye, blepharitis and other conditions to assess the relationship between dry eye and blepharitis. This data was reviewed in terms of the relationship between dry eye, menopause, and aging. Also examined in detail were many of the proposed causes for dry eye in the literature.</p><p><strong>Results: </strong>A close relationship between corneal damage and lacrimal gland function is hypothesized. Not only does decreased lacrimal gland output damage the ocular surface, but also damage to the corneal surface creates a negative feedback loop and damage to the lacrimal gland. There are probably several mechanisms by which this feedback occurs. One mechanism results from interruption or damage to the sensory corneal nerves. Damage to the nerves within the lacrimal gland may be another mechanism. Alteration of growth factor levels in the lacrimal gland, which occurs following corneal damage, represents another possible mechanism. Contact lenses and corneal refractive surgery are additional elements that may create negative feedback to the lacrimal gland.</p><p><strong>Conclusion: </strong>The ocular surface and the lacrimal gland functions as a tightly integrated unit. Dry eye conditions damage the ocular surface and this in turn leads to further damage to the lacrimal gland.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"26 3","pages":"159-65"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21785018","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1