Pub Date : 2018-10-03DOI: 10.1201/9781315222028-24
J. Whitaker
{"title":"Circuit-Level Transient Suppression","authors":"J. Whitaker","doi":"10.1201/9781315222028-24","DOIUrl":"https://doi.org/10.1201/9781315222028-24","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124965453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-33
J. Whitaker
{"title":"Units Conversion Table","authors":"J. Whitaker","doi":"10.1201/9781315222028-33","DOIUrl":"https://doi.org/10.1201/9781315222028-33","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127673681","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Transient disturbances are what headaches are made of. Whatever you call them-spikes, surges, or power bumps-they can take your equipment down and leave you with a complicated and expensive repair job. Protection against transient disturbances is a science that demands attention to detail. This book explains how the power distribution system works, what can go wrong with it, and how to protect your facility against abnormalities. System grounding and shielding are covered in detail. Each major method of transient protection is analyzed and its relative merits discussed. The book provides a complete look at the critical elements of the AC power system.
{"title":"AC Power Systems","authors":"J. Whitaker","doi":"10.1201/9781315222028-8","DOIUrl":"https://doi.org/10.1201/9781315222028-8","url":null,"abstract":"Transient disturbances are what headaches are made of. Whatever you call them-spikes, surges, or power bumps-they can take your equipment down and leave you with a complicated and expensive repair job. Protection against transient disturbances is a science that demands attention to detail. This book explains how the power distribution system works, what can go wrong with it, and how to protect your facility against abnormalities. System grounding and shielding are covered in detail. Each major method of transient protection is analyzed and its relative merits discussed. The book provides a complete look at the critical elements of the AC power system.","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"128 5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130008678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Efficient Use of Energy","authors":"I. Dryden","doi":"10.1049/TPE.1976.0099","DOIUrl":"https://doi.org/10.1049/TPE.1976.0099","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130348966","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-29
J. Whitaker
{"title":"Designing for Fault-Tolerance","authors":"J. Whitaker","doi":"10.1201/9781315222028-29","DOIUrl":"https://doi.org/10.1201/9781315222028-29","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129328156","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-25
{"title":"Grounding Practices","authors":"","doi":"10.1201/9781315222028-25","DOIUrl":"https://doi.org/10.1201/9781315222028-25","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"115 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131093757","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-18
J. Whitaker
{"title":"Power System Protection Methods","authors":"J. Whitaker","doi":"10.1201/9781315222028-18","DOIUrl":"https://doi.org/10.1201/9781315222028-18","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124324625","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-26
J. Whitaker
{"title":"Grounding Tower Elements","authors":"J. Whitaker","doi":"10.1201/9781315222028-26","DOIUrl":"https://doi.org/10.1201/9781315222028-26","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130581655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-27
J. Whitaker
{"title":"Facility Ground-System Design","authors":"J. Whitaker","doi":"10.1201/9781315222028-27","DOIUrl":"https://doi.org/10.1201/9781315222028-27","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126504461","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2018-10-03DOI: 10.1201/9781315222028-23
J. Whitaker
{"title":"Facility Wiring and Transient Protection","authors":"J. Whitaker","doi":"10.1201/9781315222028-23","DOIUrl":"https://doi.org/10.1201/9781315222028-23","url":null,"abstract":"","PeriodicalId":297296,"journal":{"name":"AC Power Systems Handbook","volume":"889 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121854180","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}