Stress distribution of endodontically treated mandibular molars with varying amounts of tooth structure restored with direct composite resin with or without cuspal coverage: A 3D finite element analysis. 有或无根尖覆盖的直接复合树脂修复不同数量牙齿结构的牙髓治疗下颌磨牙的应力分布:三维有限元分析。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-12-08 DOI: 10.4103/jcd.jcd_333_22
Ashtha Arya, Mandeep S Grewal, Vishal Arya, Ekta Choudhary, Jigyasa Duhan

Background: Decision-making regarding whether cuspal coverage is required or not for the restoration of root canal-treated posterior teeth is still a matter of challenge for the dentist.

Methodology: Four models of endodontically treated mandibular molars with mesio-occlusal (MO) cavity were designed and simulated with direct composite resin restorations. Group 1A - cavity width <½ the intercuspal distance restored without cuspal coverage, Group 1B - same as Group 1A but with cuspal coverage, Group 2A - MO cavity width >½ but <2/3rd the intercuspal distance restored without cuspal coverage, and Group 2B - same as Group 2A but with cuspal coverage. The models received occlusal load to simulate a mastication load. Static finite element analysis (FEA) was adopted for predicting the stress distribution generated in the restored tooth by the loading condition.

Results: FEA of the models have shown that the variations in stress values were significant in bulk-fill material compared to enamel and other structures. Comparing the maximum and minimum principal stress values in the overall region demonstrated that 2A was safer, whereas 2B was found to be the worst case.

Conclusions: The results indicate that restoration of endodontically treated mandibular molar with loss of one marginal ridge with composite resin without cuspal coverage revealed minimal internal stress values and showed the best performance overall.

背景:决定根管治疗后牙的修复是否需要覆盖根尖,对牙医来说仍然是一个挑战。方法:设计了四种带近中咬合腔的下颌磨牙根管治疗模型,并用直接复合树脂修复体进行了模拟。第1A组-空腔宽度为½,但d为在没有尖部覆盖的情况下恢复的尖间距离,第2B组-与第2A组相同,但有尖部覆盖。模型接受咬合负荷以模拟咀嚼负荷。采用静态有限元分析(FEA)方法,预测了不同载荷条件下修复齿的应力分布。结果:模型的有限元分析表明,与搪瓷和其他结构相比,散装填充材料的应力值变化显著。比较整个区域的最大和最小主应力值表明,2A更安全,而2B是最坏的情况。结论:结果表明,在没有根尖覆盖的情况下,用复合树脂修复缺失一个边缘嵴的牙髓治疗下颌磨牙,显示出最小的内应力值,并显示出最佳的整体性能。
{"title":"Stress distribution of endodontically treated mandibular molars with varying amounts of tooth structure restored with direct composite resin with or without cuspal coverage: A 3D finite element analysis.","authors":"Ashtha Arya,&nbsp;Mandeep S Grewal,&nbsp;Vishal Arya,&nbsp;Ekta Choudhary,&nbsp;Jigyasa Duhan","doi":"10.4103/jcd.jcd_333_22","DOIUrl":"10.4103/jcd.jcd_333_22","url":null,"abstract":"<p><strong>Background: </strong>Decision-making regarding whether cuspal coverage is required or not for the restoration of root canal-treated posterior teeth is still a matter of challenge for the dentist.</p><p><strong>Methodology: </strong>Four models of endodontically treated mandibular molars with mesio-occlusal (MO) cavity were designed and simulated with direct composite resin restorations. Group 1A - cavity width <½ the intercuspal distance restored without cuspal coverage, Group 1B - same as Group 1A but with cuspal coverage, Group 2A - MO cavity width >½ but <2/3<sup>rd</sup> the intercuspal distance restored without cuspal coverage, and Group 2B - same as Group 2A but with cuspal coverage. The models received occlusal load to simulate a mastication load. Static finite element analysis (FEA) was adopted for predicting the stress distribution generated in the restored tooth by the loading condition.</p><p><strong>Results: </strong>FEA of the models have shown that the variations in stress values were significant in bulk-fill material compared to enamel and other structures. Comparing the maximum and minimum principal stress values in the overall region demonstrated that 2A was safer, whereas 2B was found to be the worst case.</p><p><strong>Conclusions: </strong>The results indicate that restoration of endodontically treated mandibular molar with loss of one marginal ridge with composite resin without cuspal coverage revealed minimal internal stress values and showed the best performance overall.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"20-25"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003291/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9095517","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of varying dry air temperatures on postoperative sensitivity, penetration depth, and push-out bond strength of an ethanol/water-based adhesive: An in vivo double-blind clinical trial and in vitro analysis. 不同干燥空气温度对乙醇/水性粘合剂术后敏感性、渗透深度和推出粘合强度的影响:一项体内双盲临床试验和体外分析。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-12-08 DOI: 10.4103/jcd.jcd_454_22
Sachin Kumar, Palmoor Santosh Kumar, Sampath Vidhya, Sekar Mahalaxmi, Pranav Vanajassun Purushothaman

Background: Incomplete monomer infiltration into the etched dentin causes postoperative sensitivity (POS) with total-etch adhesives. Increasing the temperature of the air to dry the adhesive has shown to improve its infiltration into the dentin.

Aims: The aim of this research is to evaluate the effectiveness of dry air temperatures of 15°C ± 5°C and 50°C ± 5°C on the POS, depth of penetration, and bond strength of an ethanol/water-based etch-and-rinse (ER) adhesive under in vivo and in vitro conditions.

Methods: Forty-four premolars from 11 patients scheduled for orthodontic extraction were allocated into cold air (Group 1) and warm air (Group 2) groups using a split-mouth design. A 2 mm × 2 mm × 2 mm cavity was prepared on the middle third of the buccal surface of the teeth, acid etched, and two coats of an ethanol/water-based adhesive resin mixed with 0.1% rhodamine B was applied for 10 s. A dental air gun customized to deliver warm and cold air was used to dry the adhesive prior to its light polymerization. The cavities were restored with resin composite incrementally. POS was assessed using visual analog scale at 24 and 72 h using cold test. The teeth were atraumatically extracted and analyzed for depth of adhesive penetration using confocal laser scanning microscope (n = 11) and push-out bond strength (n = 11).

Statistical analysis used: The data were analyzed using sample t-test and Wilcoxon signed-rank test (P < 0.05).

Results: A significantly lower POS and greater adhesive penetration into the dentin was observed in the warm air group compared to cold air (P < 0.05). No significant difference could be elicited between the push-out bond strength of both the groups (P > 0.05).

Conclusions: Warm air alleviated POS and improved the penetration of an ethanol/water-based ER adhesive into the dentin.

背景:单体不完全渗透到蚀刻的牙本质中会导致全蚀刻粘合剂的术后敏感性(POS)。提高空气的温度以干燥粘合剂已经表明可以改善其对牙本质的渗透。目的:本研究的目的是评估在体内和体外条件下,15°C±5°C和50°C±6°C的干燥空气温度对乙醇/水性蚀刻和漂洗(ER)粘合剂的POS、渗透深度和粘合强度的有效性。方法:将11例正畸患者的44颗前磨牙分为冷空气组(第一组)和热空气组(第二组)。在牙齿颊表面的中间三分之一处制备一个2 mm×2 mm×2mm的空腔,进行酸蚀,并涂上两层与0.1%罗丹明B混合的乙醇/水性粘合剂树脂10 s。在粘合剂进行光聚合之前,使用定制的可输送冷空气和暖空气的牙科气枪来干燥粘合剂。用树脂复合材料逐步修复空洞。使用视觉模拟量表在24小时和72小时使用冷测试评估POS。对牙齿进行无损伤提取,并使用共聚焦激光扫描显微镜(n=11)和推出粘合强度(n=11中)分析粘合剂渗透深度。统计分析:采用样本t检验和Wilcoxon符号秩检验对数据进行分析(P<0.05)减轻了POS并改善了乙醇/水性ER粘合剂对牙本质的渗透。
{"title":"Influence of varying dry air temperatures on postoperative sensitivity, penetration depth, and push-out bond strength of an ethanol/water-based adhesive: An <i>in vivo</i> double-blind clinical trial and <i>in vitro</i> analysis.","authors":"Sachin Kumar,&nbsp;Palmoor Santosh Kumar,&nbsp;Sampath Vidhya,&nbsp;Sekar Mahalaxmi,&nbsp;Pranav Vanajassun Purushothaman","doi":"10.4103/jcd.jcd_454_22","DOIUrl":"10.4103/jcd.jcd_454_22","url":null,"abstract":"<p><strong>Background: </strong>Incomplete monomer infiltration into the etched dentin causes postoperative sensitivity (POS) with total-etch adhesives. Increasing the temperature of the air to dry the adhesive has shown to improve its infiltration into the dentin.</p><p><strong>Aims: </strong>The aim of this research is to evaluate the effectiveness of dry air temperatures of 15°C ± 5°C and 50°C ± 5°C on the POS, depth of penetration, and bond strength of an ethanol/water-based etch-and-rinse (ER) adhesive under <i>in vivo</i> and <i>in vitro</i> conditions.</p><p><strong>Methods: </strong>Forty-four premolars from 11 patients scheduled for orthodontic extraction were allocated into cold air (Group 1) and warm air (Group 2) groups using a split-mouth design. A 2 mm × 2 mm × 2 mm cavity was prepared on the middle third of the buccal surface of the teeth, acid etched, and two coats of an ethanol/water-based adhesive resin mixed with 0.1% rhodamine B was applied for 10 s. A dental air gun customized to deliver warm and cold air was used to dry the adhesive prior to its light polymerization. The cavities were restored with resin composite incrementally. POS was assessed using visual analog scale at 24 and 72 h using cold test. The teeth were atraumatically extracted and analyzed for depth of adhesive penetration using confocal laser scanning microscope (<i>n</i> = 11) and push-out bond strength (<i>n</i> = 11).</p><p><strong>Statistical analysis used: </strong>The data were analyzed using sample <i>t</i>-test and Wilcoxon signed-rank test (<i>P</i> < 0.05).</p><p><strong>Results: </strong>A significantly lower POS and greater adhesive penetration into the dentin was observed in the warm air group compared to cold air (<i>P</i> < 0.05). No significant difference could be elicited between the push-out bond strength of both the groups (<i>P</i> > 0.05).</p><p><strong>Conclusions: </strong>Warm air alleviated POS and improved the penetration of an ethanol/water-based ER adhesive into the dentin.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"88-93"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003293/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9101064","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of pH and calcium ions release of two tricalcium silicate-based sealers through roots of primary teeth. 两种硅酸三钙基密封剂通过乳牙根部的pH值和钙离子释放的评估。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-08-17 DOI: 10.4103/jcd.jcd_355_21
Apoliana Reis da Silva, Eduardo Antunes Bortoluzzi, Filipe Colombo Vitali, Michele Bolan, Mariane Cardoso

Background: This study aimed to evaluate the pH and calcium ions (Ca2+) release from two tricalcium silicate-based sealers (Sealer Plus BC and Bio-C Pulpecto) through roots of primary teeth.

Methods: Forty root canals of primary incisors were prepared and distributed into four groups according to the filling material: GPlusBC (Sealer Plus BC); GBioC (Bio-C Pulpecto); GUltra (Ultracal); and GC (no filled). pH measurement was performed with a digital pH meter, and the Ca2+ release was measured in an atomic absorption spectrophotometer at baseline, 24 h and 1, 2, 3, and 4 weeks later. The data were analyzed using two-way ANOVA and Tukey's post hoc tests.

Results: The results did not reveal significant differences between the groups in terms of pH in 24 h, 1-, and 2-weeks' periods. After 4 weeks, there was a significant difference, with the highest mean pH values in GUltra, followed, respectively, by GPlusBC and GBioC. Regarding the Ca2+ release, the GUltra showed greatest mean values at all evaluated times, and the other groups showed no difference between them.

Conclusion: Both sealers were able to promote the elevation of the pH and Ca2+ release through roots of primary teeth, which brings favorable properties for their use as a filling material.

背景:本研究旨在评估两种基于硅酸三钙的密封剂(Sealer Plus BC和Bio-C Pulpecto)通过乳牙根部释放的pH值和钙离子(Ca2+)。方法:制备40根原切牙根管,按充填材料分为四组:GPlusBC(Sealer Plus BC);GBioC(Bio-C Pulpecto);GUltra(Ultracal);和GC(未填充)。用数字pH计进行pH测量,并在基线、24小时以及1、2、3和4周后用原子吸收分光光度计测量Ca2+释放。使用双向方差分析和Tukey的事后检验对数据进行分析。结果:在24小时、1周和2周的时间内,两组之间的pH值没有显著差异。4周后,出现了显著差异,GUltra的平均pH值最高,其次分别是GPlusBC和GBioC。关于Ca2+释放,GUltra在所有评估时间显示出最大的平均值,其他组之间没有差异。结论:两种封闭剂均能促进乳牙根部pH值的升高和Ca2+的释放,为其作为充填材料提供了良好的性能。
{"title":"Evaluation of pH and calcium ions release of two tricalcium silicate-based sealers through roots of primary teeth.","authors":"Apoliana Reis da Silva,&nbsp;Eduardo Antunes Bortoluzzi,&nbsp;Filipe Colombo Vitali,&nbsp;Michele Bolan,&nbsp;Mariane Cardoso","doi":"10.4103/jcd.jcd_355_21","DOIUrl":"10.4103/jcd.jcd_355_21","url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate the pH and calcium ions (Ca<sup>2+</sup>) release from two tricalcium silicate-based sealers (Sealer Plus BC and Bio-C Pulpecto) through roots of primary teeth.</p><p><strong>Methods: </strong>Forty root canals of primary incisors were prepared and distributed into four groups according to the filling material: G<sub>PlusBC</sub> (Sealer Plus BC); G<sub>BioC</sub> (Bio-C Pulpecto); G<sub>Ultra</sub> (Ultracal); and G<sub>C</sub> (no filled). pH measurement was performed with a digital pH meter, and the Ca<sup>2</sup>+ release was measured in an atomic absorption spectrophotometer at baseline, 24 h and 1, 2, 3, and 4 weeks later. The data were analyzed using two-way ANOVA and Tukey's post hoc tests.</p><p><strong>Results: </strong>The results did not reveal significant differences between the groups in terms of pH in 24 h, 1-, and 2-weeks' periods. After 4 weeks, there was a significant difference, with the highest mean pH values in G<sub>Ultra</sub>, followed, respectively, by G<sub>PlusBC</sub> and G<sub>BioC</sub>. Regarding the Ca<sup>2</sup>+ release, the G<sub>Ultra</sub> showed greatest mean values at all evaluated times, and the other groups showed no difference between them.</p><p><strong>Conclusion: </strong>Both sealers were able to promote the elevation of the pH and Ca<sup>2</sup>+ release through roots of primary teeth, which brings favorable properties for their use as a filling material.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"42-46"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003284/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9101072","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of autoclave sterilization on the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-one nickel-titanium endodontic instruments. 高压灭菌对EdgeFile X7、2Shape和F-one镍钛根管器械抗循环疲劳性能的影响。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-08-17 DOI: 10.4103/jcd.jcd_611_21
Arkan H Al-Amidi, Hikmet Abdul-Rahim Al-Gharrawi

Background: Rotary nickel-titanium files have become the most commonly used engine-powered endodontic instruments due to their improvement in fatigue resistance and flexibility. The autoclaving is the most commonly used method for sterilization. However, the risk of instrument fracture, mainly due to cyclic fatigue during rotation within a curved canal, is still a matter of critical concern.

Aims: This study aimed to measure and compares the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-One files in a single curved simulated canal before and after autoclave sterilization.

Materials and methods: Twenty-four files each of EdgeFile X7, 2Shape, and F-One files were used in this study. They were grouped as group A: EdgeFile X7, group B: 2Shape, and group C: F-One files. Then, each group was subdivided into two, sterilized and nonsterilized, subgroups. The files were tested using a custom-made artificial canal. The number of cycles to fracture (NCF) was calculated.

Statistical analysis used: One-way analysis of variance, post hoc Tukey's test, and independent t-test were used.

Results: In nonsterilized instruments, the NCF of the EdgeFile X7 group was significantly higher than that in the other groups (P < 0.05). In sterilized instruments, there was a nonsignificant difference in NCF between EdgeFile X7 and F-One files (P > 0.05). The NCF of 2Shape was significantly lower than other files (P ≤ 0.05) in sterilized and nonsterilized groups. The autoclaving significantly decreased (P ≤ 0.05) the cyclic fatigue resistance of the tested files.

Conclusions: EdgeFile X7 was the most fatigue resistant. Autoclaving reduced the cyclic fatigue resistance of the tested files.

背景:旋转镍钛锉由于其抗疲劳性和柔韧性的提高,已成为最常用的发动机驱动牙髓病仪器。高压灭菌是最常用的灭菌方法。然而,器械断裂的风险,主要是由于弯曲管内旋转过程中的循环疲劳,仍然是一个关键问题。目的:本研究旨在测量和比较EdgeFile X7、2Shape和F-One锉刀在高压灭菌前后在单个弯曲模拟管中的循环疲劳抗力。材料和方法:本研究中使用了24个EdgeFile X7、2Shape和F-One文件。它们被分为A组:EdgeFile X7、B组:2Shape和C组:F-One文件。然后,每组被细分为两个亚组,灭菌和未灭菌。这些锉刀是用特制的人工管进行测试的。计算断裂循环次数(NCF)。采用统计学分析:采用单向方差分析、事后Tukey检验和独立t检验。结果:在未灭菌器械中,EdgeFile X7组的NCF显著高于其他组(P<0.05)。高压灭菌显著降低了试件的循环疲劳抗力(P≤0.05)。结论:EdgeFile X7是最耐疲劳的。高压灭菌降低了被测锉刀的抗循环疲劳性能。
{"title":"Effect of autoclave sterilization on the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-one nickel-titanium endodontic instruments.","authors":"Arkan H Al-Amidi,&nbsp;Hikmet Abdul-Rahim Al-Gharrawi","doi":"10.4103/jcd.jcd_611_21","DOIUrl":"10.4103/jcd.jcd_611_21","url":null,"abstract":"<p><strong>Background: </strong>Rotary nickel-titanium files have become the most commonly used engine-powered endodontic instruments due to their improvement in fatigue resistance and flexibility. The autoclaving is the most commonly used method for sterilization. However, the risk of instrument fracture, mainly due to cyclic fatigue during rotation within a curved canal, is still a matter of critical concern.</p><p><strong>Aims: </strong>This study aimed to measure and compares the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-One files in a single curved simulated canal before and after autoclave sterilization.</p><p><strong>Materials and methods: </strong>Twenty-four files each of EdgeFile X7, 2Shape, and F-One files were used in this study. They were grouped as group A: EdgeFile X7, group B: 2Shape, and group C: F-One files. Then, each group was subdivided into two, sterilized and nonsterilized, subgroups. The files were tested using a custom-made artificial canal. The number of cycles to fracture (NCF) was calculated.</p><p><strong>Statistical analysis used: </strong>One-way analysis of variance, post hoc Tukey's test, and independent <i>t</i>-test were used.</p><p><strong>Results: </strong>In nonsterilized instruments, the NCF of the EdgeFile X7 group was significantly higher than that in the other groups (<i>P</i> < 0.05). In sterilized instruments, there was a nonsignificant difference in NCF between EdgeFile X7 and F-One files (<i>P</i> > 0.05). The NCF of 2Shape was significantly lower than other files (<i>P</i> ≤ 0.05) in sterilized and nonsterilized groups. The autoclaving significantly decreased (<i>P</i> ≤ 0.05) the cyclic fatigue resistance of the tested files.</p><p><strong>Conclusions: </strong>EdgeFile X7 was the most fatigue resistant. Autoclaving reduced the cyclic fatigue resistance of the tested files.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"26-30"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003289/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9101073","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of the incidence of postoperative pain in single sitting root canal treatment after using two reciprocating systems and two continuous rotary systems: An in vivo study. 使用两种往复式系统和两种连续旋转系统进行单次坐位根管治疗后术后疼痛发生率的比较:一项体内研究。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-12-08 DOI: 10.4103/jcd.jcd_331_22
Vijay Kumar Vijayran, Ambica Khetarpal, Asit Vats, Monika Ahlawat, Neha Singhal, Harshita

Aim: The aim of the present study was to compare the incidence of postoperative pain in single sitting root canal treatment after using two reciprocating and two continuous rotating file systems.

Methodology: One hundred and four permanent mandibular canine and first premolar teeth were selected for the study and were divided into two groups 1 and 2 comprising 52 teeth each. Group 1 was treated using reciprocating file systems and was subdivided into two subgroups A and B using WaveOne Gold (WOG) and Reciproc Blue (RB), respectively. Group 2 was treated using continuous rotating file systems and was divided into two subgroups A and B using One Curve (OC) and Vortex Blue (VB), respectively. Treatments were performed in a single sitting. After the visit, the patients were given a prescription for ibuprofen 400 mg to be taken every 6 h if they experience pain. Participants were asked to rate the intensity of the postoperative pain on a visual analog scale according to four classes (no pain, mild pain, moderate pain, and severe pain) after 24 h, 48 h, 72 h, and 7 days. Patients were also asked to record the number of prescribed analgesic medication tablets taken at these time points.

Results: There was a statistically significant difference (P = 0.00) among the reciprocating file systems and continuous file systems regarding the incidence of postoperative pain after 24, 48, and 72 h which signifies that pain incidence and duration is less with respect to reciprocation instrumentation as compared to continuous instrumentation.

Conclusion: The use of Reciproc instrumentation system (WOG and RB) showed significantly less intensity and duration of posttreatment pain compared to the single-file rotary system (OC and VB) in patients with symptomatic irreversible pulpitis with apical periodontitis.

目的:本研究的目的是比较使用两种往复式和两种连续旋转锉系统进行单次坐位根管治疗后的术后疼痛发生率。方法:选择104颗下颌永久性犬齿和第一前臼齿进行研究,分为第一组和第二组,每组52颗牙齿。第1组使用往复式锉刀系统进行治疗,并分别使用WaveOne Gold(WOG)和往复式Blue(RB)细分为两个亚组A和B。第2组使用连续旋转文件系统进行治疗,并分别使用One Curve(OC)和Vortex Blue(VB)分为两个亚组A和B。治疗是一次坐着进行的。访视后,如果患者感到疼痛,每6小时给他们开一次布洛芬400 mg的处方。参与者被要求在24小时、48小时、72小时和7天后,根据四个级别(无疼痛、轻度疼痛、中度疼痛和重度疼痛),在视觉模拟量表上对术后疼痛的强度进行评分。患者还被要求记录在这些时间点服用的处方止痛药的数量。结果:在24、48和72小时后,往复式文件系统和连续文件系统的术后疼痛发生率存在统计学显著差异(P=0.00),这意味着与连续器械相比,往复式器械的疼痛发生率和持续时间更短。结论:与单锉旋转系统(OC和VB)相比,使用往复式器械系统(WOG和RB)治疗症状性不可逆牙髓炎伴根尖周炎的患者,其治疗后疼痛的强度和持续时间显著降低。
{"title":"Comparison of the incidence of postoperative pain in single sitting root canal treatment after using two reciprocating systems and two continuous rotary systems: An <i>in vivo</i> study.","authors":"Vijay Kumar Vijayran,&nbsp;Ambica Khetarpal,&nbsp;Asit Vats,&nbsp;Monika Ahlawat,&nbsp;Neha Singhal,&nbsp;Harshita","doi":"10.4103/jcd.jcd_331_22","DOIUrl":"10.4103/jcd.jcd_331_22","url":null,"abstract":"<p><strong>Aim: </strong>The aim of the present study was to compare the incidence of postoperative pain in single sitting root canal treatment after using two reciprocating and two continuous rotating file systems.</p><p><strong>Methodology: </strong>One hundred and four permanent mandibular canine and first premolar teeth were selected for the study and were divided into two groups 1 and 2 comprising 52 teeth each. Group 1 was treated using reciprocating file systems and was subdivided into two subgroups A and B using WaveOne Gold (WOG) and Reciproc Blue (RB), respectively. Group 2 was treated using continuous rotating file systems and was divided into two subgroups A and B using One Curve (OC) and Vortex Blue (VB), respectively. Treatments were performed in a single sitting. After the visit, the patients were given a prescription for ibuprofen 400 mg to be taken every 6 h if they experience pain. Participants were asked to rate the intensity of the postoperative pain on a visual analog scale according to four classes (no pain, mild pain, moderate pain, and severe pain) after 24 h, 48 h, 72 h, and 7 days. Patients were also asked to record the number of prescribed analgesic medication tablets taken at these time points.</p><p><strong>Results: </strong>There was a statistically significant difference (<i>P</i> = 0.00) among the reciprocating file systems and continuous file systems regarding the incidence of postoperative pain after 24, 48, and 72 h which signifies that pain incidence and duration is less with respect to reciprocation instrumentation as compared to continuous instrumentation.</p><p><strong>Conclusion: </strong>The use of Reciproc instrumentation system (WOG and RB) showed significantly less intensity and duration of posttreatment pain compared to the single-file rotary system (OC and VB) in patients with symptomatic irreversible pulpitis with apical periodontitis.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"12-19"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003282/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9095521","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Microleakage Studies - A Viewpoint. 微渗漏研究——一种观点。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2023-01-17 DOI: 10.4103/jcd.jcd_1_23
Shishir Singh
{"title":"Microleakage Studies - A Viewpoint.","authors":"Shishir Singh","doi":"10.4103/jcd.jcd_1_23","DOIUrl":"10.4103/jcd.jcd_1_23","url":null,"abstract":"","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"1-2"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003292/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9101070","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
"Eat the Rainbow" Approach in Chromotherapy. “吃彩虹”的方法在色彩疗法。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2023-01-17 DOI: 10.4103/jcd.jcd_511_22
V Venugopal, Deenadayalan Boopalan, R Poornima, K Maheshkumar
{"title":"\"Eat the Rainbow\" Approach in Chromotherapy.","authors":"V Venugopal,&nbsp;Deenadayalan Boopalan,&nbsp;R Poornima,&nbsp;K Maheshkumar","doi":"10.4103/jcd.jcd_511_22","DOIUrl":"10.4103/jcd.jcd_511_22","url":null,"abstract":"","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"118-119"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003281/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9095516","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Bonding strategies to deal with caries-affected dentin using cross-linking agents: Grape seed extract, green tea extract, and glutaraldehyde - An in vitro study. 使用交联剂处理龋齿影响的牙本质的粘合策略:葡萄籽提取物、绿茶提取物和戊二醛——一项体外研究。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2023-01-17 DOI: 10.4103/jcd.jcd_485_22
Shrusti Ajay Govil, Geeta Asthana, Vardhesh Achyut Sail

Aim: This study evaluated the effect of three collagen cross-linking agents - proanthocyanidins (grape seed extract [GSE] and green tea extract [GTE]) and glutaraldehyde [GA] on microshear bond strength (μSBS) of caries-affected dentin (CAD)-resin complex.

Materials and methods: Freshly extracted 96 teeth with caries up to the middle third of dentin were sectioned through the deepest part of the occlusal fissure, perpendicular to the long axis of the crown. Caries was excavated with large round bur until firm dentin was obtained, confirmed by visual inspection and tactile examination. Flat occlusal dentin surfaces were treated as follows: Group-1 - 6.5% GSE (n = 30), Group-2 - 2% GTE (n = 30), Group-3 - 5% Glutaraldehyde (n = 30), Group-4 - control group (no agents) (n = 6). Each group was further divided into Subgroup A - Etch-N-Rinse 15s, Subgroup B - Etch-N-Rinse 45s, and Subgroup C - Self-etch. Two increments of 1.5-mm thick composite (Tetric-N-Ceram - Ivoclar Vivadent) with a 1-mm diameter were built-up. Each sample was subjected to μSBS test in Universal Testing Machine. Student's t-test was done for intragroup comparison and one-way ANOVA for intergroup comparison.

Results: Statistically significant difference was present in mean μSBS, with Group 1B showing the best results and Group 4C, the least.

Conclusions: Thus, the application of these collagen cross-linkers, to CAD, increases μSBS and promises a new approach to improve dentin bond strength.

目的:评价三种胶原交联剂——原花青素(葡萄籽提取物和绿茶提取物)和戊二醛(GA)对患龋牙本质(CAD)-树脂复合体微剪切结合强度(μSBS)的影响。材料和方法:新鲜拔除的96颗龋齿至牙本质中三分之一的牙齿,垂直于牙冠长轴,通过咬合裂的最深部分进行切片。用大圆钻挖出龋齿,直到获得牢固的牙本质,并通过视觉检查和触觉检查进行确认。扁平咬合牙本质表面处理如下:第1组-6.5%GSE(n=30),第2组-2%GTE(n=30。每组进一步分为亚组A-蚀刻-N-Rinse 15s、亚组B-蚀刻-N-Rines 45s和亚组C-自蚀刻。构建了两个直径为1mm的1.5mm厚的增量复合材料(Tetric-N-Ceram-Ivoclar-Vivadent)。每个样品在万能试验机中进行μSBS试验。组内比较采用Student t检验,组间比较采用单因素方差分析。结果:平均μSBS存在统计学上的显著差异,其中1B组的结果最好,4C组的结果最少。结论:因此,这些胶原交联剂在CAD中的应用增加了μSBS,有望为提高牙本质结合强度提供一种新的途径。
{"title":"Bonding strategies to deal with caries-affected dentin using cross-linking agents: Grape seed extract, green tea extract, and glutaraldehyde - An <i>in vitro</i> study.","authors":"Shrusti Ajay Govil,&nbsp;Geeta Asthana,&nbsp;Vardhesh Achyut Sail","doi":"10.4103/jcd.jcd_485_22","DOIUrl":"10.4103/jcd.jcd_485_22","url":null,"abstract":"<p><strong>Aim: </strong>This study evaluated the effect of three collagen cross-linking agents - proanthocyanidins (grape seed extract [GSE] and green tea extract [GTE]) and glutaraldehyde [GA] on microshear bond strength (μSBS) of caries-affected dentin (CAD)-resin complex.</p><p><strong>Materials and methods: </strong>Freshly extracted 96 teeth with caries up to the middle third of dentin were sectioned through the deepest part of the occlusal fissure, perpendicular to the long axis of the crown. Caries was excavated with large round bur until firm dentin was obtained, confirmed by visual inspection and tactile examination. Flat occlusal dentin surfaces were treated as follows: Group-1 - 6.5% GSE (<i>n</i> = 30), Group-2 - 2% GTE (<i>n</i> = 30), Group-3 - 5% Glutaraldehyde (<i>n</i> = 30), Group-4 - control group (no agents) (<i>n</i> = 6). Each group was further divided into Subgroup A - Etch-N-Rinse 15s, Subgroup B - Etch-N-Rinse 45s, and Subgroup C - Self-etch. Two increments of 1.5-mm thick composite (Tetric-N-Ceram - Ivoclar Vivadent) with a 1-mm diameter were built-up. Each sample was subjected to μSBS test in Universal Testing Machine. Student's <i>t</i>-test was done for intragroup comparison and one-way ANOVA for intergroup comparison.</p><p><strong>Results: </strong>Statistically significant difference was present in mean μSBS, with Group 1B showing the best results and Group 4C, the least.</p><p><strong>Conclusions: </strong>Thus, the application of these collagen cross-linkers, to CAD, increases μSBS and promises a new approach to improve dentin bond strength.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"108-112"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003275/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9101062","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effect of different polishing systems and speeds on the surface roughness of resin composites. 不同抛光系统和抛光速度对树脂复合材料表面粗糙度的影响。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-12-08 DOI: 10.4103/jcd.jcd_395_22
Hatice Tepe, Ayse Dina Erdılek, Merve Sahın, Begüm Güray Efes, Batu Can Yaman

Aims and objectives: The objective of this study was to compare surface roughness of a nano-spherical resin composite using four different multi-step polishing disc systems at five different speeds.

Materials and methods: In total, 154 discs samples were prepared using a supra-nano spherical resin composite. The samples were divided into negative and positive control groups and the following four finishing and polishing disc systems: Sof-Lex, Bisco Finishing Discs, OptiDisc, and Super-Snap. Each polishing disc system was applied at five different speeds (2000, 5000, 10,000, 15,000, and 20,000 revolutions per minute [RPM]) (n = 7). The surface roughness of samples was measured using a profilometer. One sample from each group was evaluated by scanning electron microscopy and atomic force microscopy. Two-way analysis of variance was used to evaluate the average roughness (Ra) data from the profilometric experiments using statistical software (GraphPad Prism4-GraphPad Software; La Jolla, CA, USA). The mean values were compared using the Bonferroni test (P = 0.05).

Results: The mean roughness ranged from 0.07 μm to 0.41 μm. The smoothest surfaces were obtained with OptiDisc at 20,000 RPM and Super-Snap at 20,000 RPM. The Bisco Finishing Discs group at 2,000 RPM showed the highest surface roughness values. For all polishing systems, the roughness at 20,000 RPM was lower than that at other speeds.

Conclusion: Within the limitations of the present in vitro study, it can be concluded that the polishing performance was in the following order: Super-Snap > OptiDisc > Sof-Lex > Bisco Finishing Discs. In addition, the surface roughness decreased as the polishing speed increased.

目的和目的:本研究的目的是比较使用四种不同的多步骤抛光盘系统在五种不同速度下纳米球形树脂复合材料的表面粗糙度。材料和方法:使用超纳米球形树脂复合材料总共制备了154个圆盘样品。将样品分为阴性和阳性对照组以及以下四种精加工和抛光盘系统:Sof Lex、Bisco精加工盘、OptiDisc和Super Snap。每个抛光盘系统以五种不同的速度(2000、5000、10000、15000和20000转/分钟[RPM])(n=7)应用。使用轮廓仪测量样品的表面粗糙度。通过扫描电子显微镜和原子力显微镜对每组中的一个样品进行评估。双向方差分析用于使用统计软件(GraphPad Prism4 GraphPad software;美国加利福尼亚州拉霍亚)评估来自轮廓测量实验的平均粗糙度(Ra)数据。结果:平均粗糙度范围为0.07μm~0.41μm。OptiDisc在20000RPM和Super Snap在20000RPM下获得了最光滑的表面。Bisco Finishing Discs组在2000RPM下显示出最高的表面粗糙度值。对于所有抛光系统,20000RPM下的粗糙度低于其他速度下的粗糙程度。结论:在目前体外研究的限制范围内,可以得出结论,抛光性能依次为:Super Snap>OptiDisc>Sof Lex>Bisco Finishing Discs。此外,表面粗糙度随着抛光速度的增加而降低。
{"title":"Effect of different polishing systems and speeds on the surface roughness of resin composites.","authors":"Hatice Tepe,&nbsp;Ayse Dina Erdılek,&nbsp;Merve Sahın,&nbsp;Begüm Güray Efes,&nbsp;Batu Can Yaman","doi":"10.4103/jcd.jcd_395_22","DOIUrl":"10.4103/jcd.jcd_395_22","url":null,"abstract":"<p><strong>Aims and objectives: </strong>The objective of this study was to compare surface roughness of a nano-spherical resin composite using four different multi-step polishing disc systems at five different speeds.</p><p><strong>Materials and methods: </strong>In total, 154 discs samples were prepared using a supra-nano spherical resin composite. The samples were divided into negative and positive control groups and the following four finishing and polishing disc systems: Sof-Lex, Bisco Finishing Discs, OptiDisc, and Super-Snap. Each polishing disc system was applied at five different speeds (2000, 5000, 10,000, 15,000, and 20,000 revolutions per minute [RPM]) (<i>n</i> = 7). The surface roughness of samples was measured using a profilometer. One sample from each group was evaluated by scanning electron microscopy and atomic force microscopy. Two-way analysis of variance was used to evaluate the average roughness (Ra) data from the profilometric experiments using statistical software (GraphPad Prism4-GraphPad Software; La Jolla, CA, USA). The mean values were compared using the Bonferroni test (<i>P</i> = 0.05).</p><p><strong>Results: </strong>The mean roughness ranged from 0.07 μm to 0.41 μm. The smoothest surfaces were obtained with OptiDisc at 20,000 RPM and Super-Snap at 20,000 RPM. The Bisco Finishing Discs group at 2,000 RPM showed the highest surface roughness values. For all polishing systems, the roughness at 20,000 RPM was lower than that at other speeds.</p><p><strong>Conclusion: </strong>Within the limitations of the present <i>in vitro</i> study, it can be concluded that the polishing performance was in the following order: Super-Snap > OptiDisc > Sof-Lex > Bisco Finishing Discs. In addition, the surface roughness decreased as the polishing speed increased.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"36-41"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003290/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9095518","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A comparative study on microleakage of two low shrinkage composite materials in Class II cavities: A stereomicroscopic analysis. 两种低收缩复合材料在II类空腔中微渗漏的比较研究:立体显微镜分析。
Q2 Dentistry Pub Date : 2023-01-01 Epub Date: 2022-12-08 DOI: 10.4103/jcd.jcd_444_22
Gifty Jacob, K Mallikarjun Goud

Aim: To compare the microleakage of Filtek bulk fill posterior and Beautifil II LS composites in Class II cavities using stereomicroscope.

Materials and methods: A total of 34 extracted teeth were randomly divided into two groups. Teeth were prepared and mounted on a plaster block. In each tooth, Class II cavities were prepared, following which the cavities were etched and bonded. In Group I, 17 teeth were restored with Filtek bulk fill posterior composite in bulk fill technique and in Group II, 17 teeth were restored with Beautifil II LS following manufacture's instructions. The samples were then thermocycled and then the tooth were immersed in 1% methylene blue for 24 h and were divided into two halves mesiodistally using a diamond disc at low speed. Then, all the sections were observed under a stereomicroscope at ×10 magnification.

Results: Mann-Whitney U-test displayed a statistically significant higher mean rank among Filtek bulk fill group (mean rank = 23.09) when compared to Beautifil II LS composite group (mean rank = 11.91).

Conclusion: The study concluded that in Class II restorations, Beautifil II LS showed significantly less microleakage than Filtek bulk fill posterior.

目的:用立体显微镜比较Filtek大块填充后部和Beautifil II LS复合材料在II类空腔中的微渗漏。材料和方法:将34颗拔除的牙齿随机分为两组。牙齿已经准备好并安装在石膏块上。在每颗牙齿中,制备II类蛀牙,然后对蛀牙进行蚀刻和粘合。在第一组中,17颗牙齿采用Filtek大块充填-后部复合材料在大块充填技术中进行了修复,在第二组中,根据制造商的说明,用Beautifil II LS进行了17颗牙齿的修复。然后对样品进行热循环,然后将牙齿浸入1%亚甲蓝中24小时,并使用金刚石圆盘以低速将其分为两半。然后,在放大10倍的立体显微镜下观察所有切片。结果:与Beautifil II LS复合组(平均等级=11.91)相比,Filtek大块填充组的Mann-Whitney U型检验显示出统计学上显著更高的平均等级(平均等级=23.09)。
{"title":"A comparative study on microleakage of two low shrinkage composite materials in Class II cavities: A stereomicroscopic analysis.","authors":"Gifty Jacob,&nbsp;K Mallikarjun Goud","doi":"10.4103/jcd.jcd_444_22","DOIUrl":"10.4103/jcd.jcd_444_22","url":null,"abstract":"<p><strong>Aim: </strong>To compare the microleakage of Filtek bulk fill posterior and Beautifil II LS composites in Class II cavities using stereomicroscope.</p><p><strong>Materials and methods: </strong>A total of 34 extracted teeth were randomly divided into two groups. Teeth were prepared and mounted on a plaster block. In each tooth, Class II cavities were prepared, following which the cavities were etched and bonded. In Group I, 17 teeth were restored with Filtek bulk fill posterior composite in bulk fill technique and in Group II, 17 teeth were restored with Beautifil II LS following manufacture's instructions. The samples were then thermocycled and then the tooth were immersed in 1% methylene blue for 24 h and were divided into two halves mesiodistally using a diamond disc at low speed. Then, all the sections were observed under a stereomicroscope at ×10 magnification.</p><p><strong>Results: </strong>Mann-Whitney U-test displayed a statistically significant higher mean rank among Filtek bulk fill group (mean rank = 23.09) when compared to Beautifil II LS composite group (mean rank = 11.91).</p><p><strong>Conclusion: </strong>The study concluded that in Class II restorations, Beautifil II LS showed significantly less microleakage than Filtek bulk fill posterior.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 1","pages":"83-87"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003287/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9095520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Journal of Conservative Dentistry
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1