Determination of the design parameters of passive harmonic filters using nonlinear optimization 用非线性优化法确定无源谐波滤波器的设计参数
S. Upadhye, Y. Atre
Power system harmonics are a menace with disastrous consequences. A number of ways were tried out to tackle the harmonic problem posed by nonlinear electric devices, but by far, the most popular and quite effective one is the use of passive filters. This provides a low impedance path to a harmonic or a group of harmonics. Usually the AC harmonics are odd harmonics. So normally the filter combination selected is such that for the predominant harmonics, one or more single tuned filters are used, and for the rest of the harmonics, a high pass filter is used. An alternate combination is that a damped filter is used for the two predominant harmonics with the filter being tuned at a frequency in between the two harmonics and another damped filter for the higher harmonics. If all the harmonics are not of very high magnitude then usually one high pass filter is sufficient for all the harmonics. Instead of the conventional design of these filters, which is based on experience of the designer, a better way is to use the optimization algorithms to obtain maximum performance from these filters.
电力系统谐波是一种具有灾难性后果的威胁。为了解决非线性电子器件引起的谐波问题,人们尝试了许多方法,但到目前为止,最流行和最有效的方法是使用无源滤波器。这为一个谐波或一组谐波提供了一个低阻抗路径。通常交流谐波是奇次谐波。因此,通常选择的滤波器组合是这样的:对于主要谐波,使用一个或多个单调谐滤波器,而对于其余的谐波,使用高通滤波器。另一种组合是,一个阻尼滤波器用于两个主要谐波,滤波器在两个谐波之间的频率调谐,另一个阻尼滤波器用于更高的谐波。如果所有的谐波都不是非常高的幅度,那么通常一个高通滤波器就足以处理所有的谐波。这些滤波器的传统设计是基于设计者的经验,而更好的方法是使用优化算法来获得这些滤波器的最大性能。
{"title":"Determination of the design parameters of passive harmonic filters using nonlinear optimization","authors":"S. Upadhye, Y. Atre","doi":"10.1109/ICPS.1998.692558","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692558","url":null,"abstract":"Power system harmonics are a menace with disastrous consequences. A number of ways were tried out to tackle the harmonic problem posed by nonlinear electric devices, but by far, the most popular and quite effective one is the use of passive filters. This provides a low impedance path to a harmonic or a group of harmonics. Usually the AC harmonics are odd harmonics. So normally the filter combination selected is such that for the predominant harmonics, one or more single tuned filters are used, and for the rest of the harmonics, a high pass filter is used. An alternate combination is that a damped filter is used for the two predominant harmonics with the filter being tuned at a frequency in between the two harmonics and another damped filter for the higher harmonics. If all the harmonics are not of very high magnitude then usually one high pass filter is sufficient for all the harmonics. Instead of the conventional design of these filters, which is based on experience of the designer, a better way is to use the optimization algorithms to obtain maximum performance from these filters.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133299989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
A voltage-normalized network model for improved decoupled power system calculation 一种改进解耦电力系统计算的电压归一化网络模型
Lu Wang, X. Rong Li
Decoupled power system calculation methods are developed upon some assumptions, one of which is that the bus voltages are near the nominal value. In the cases where there are buses with low voltages, the efficiency or accuracy of decoupled calculation methods degrades. This paper presents a voltage-normalized network model which restores the low bus voltages to the vicinity of the nominal value. The decoupled calculation methods based on this network model do not suffer from the voltage problems and perform well in the cases of low voltages in power systems. Numerical results are presented to show the validity of this network model.
解耦电力系统的计算方法建立在一些假设的基础上,其中一个假设是母线电压接近标称值。在存在低电压母线的情况下,解耦计算方法的效率或准确性会下降。本文提出了一种电压归一化网络模型,该模型能将低母线电压恢复到标称值附近。基于该网络模型的解耦计算方法不受电压问题的影响,在电力系统低压情况下也能很好地工作。数值结果表明了该网络模型的有效性。
{"title":"A voltage-normalized network model for improved decoupled power system calculation","authors":"Lu Wang, X. Rong Li","doi":"10.1109/ICPS.1998.692560","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692560","url":null,"abstract":"Decoupled power system calculation methods are developed upon some assumptions, one of which is that the bus voltages are near the nominal value. In the cases where there are buses with low voltages, the efficiency or accuracy of decoupled calculation methods degrades. This paper presents a voltage-normalized network model which restores the low bus voltages to the vicinity of the nominal value. The decoupled calculation methods based on this network model do not suffer from the voltage problems and perform well in the cases of low voltages in power systems. Numerical results are presented to show the validity of this network model.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123060009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Using fixed gear mounted power quality monitors to perform a power factor and harmonic analysis 使用固定齿轮安装的电能质量监测器执行功率因数和谐波分析
J. Mays, W. Vilcheck, L. J. Harris, T. Domitrovich
Industrial plant electrical engineers are installing gear-mounted power quality monitors for monitoring power usage and demand for processes within their facility. Engineers also monitor and trend power quality-related parameters to detect equipment misoperation or potential power system trouble. This paper briefly describes an actual plant-wide gear-mounted power quality meter installation at a tire manufacturing facility. Just after the monitoring system was functional, power system engineers initiated a power factor correction/harmonic analysis of the plant. The power quality monitoring system provided harmonic voltage and current magnitudes throughout the electrical distribution system. The authors focus upon the contribution and advantages of a fixed gear-mounted power quality monitoring system to complete a power factor and harmonic study.
工业工厂的电气工程师正在安装安装在齿轮上的电能质量监测器,以监测工厂内的电力使用情况和工艺需求。工程师还监测和趋势电能质量相关参数,以检测设备误操作或潜在的电力系统故障。本文简要介绍了在某轮胎制造厂安装全厂齿轮传动电能质量仪表的实际情况。就在监测系统运行后,电力系统工程师启动了电厂的功率因数校正/谐波分析。电能质量监测系统为整个配电系统提供谐波电压和电流大小。本文着重介绍了固定式齿轮传动电能质量监测系统在完成功率因数和谐波研究方面的贡献和优势。
{"title":"Using fixed gear mounted power quality monitors to perform a power factor and harmonic analysis","authors":"J. Mays, W. Vilcheck, L. J. Harris, T. Domitrovich","doi":"10.1109/ICPS.1998.692538","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692538","url":null,"abstract":"Industrial plant electrical engineers are installing gear-mounted power quality monitors for monitoring power usage and demand for processes within their facility. Engineers also monitor and trend power quality-related parameters to detect equipment misoperation or potential power system trouble. This paper briefly describes an actual plant-wide gear-mounted power quality meter installation at a tire manufacturing facility. Just after the monitoring system was functional, power system engineers initiated a power factor correction/harmonic analysis of the plant. The power quality monitoring system provided harmonic voltage and current magnitudes throughout the electrical distribution system. The authors focus upon the contribution and advantages of a fixed gear-mounted power quality monitoring system to complete a power factor and harmonic study.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126614428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effects of voltage harmonics on the electrical and mechanical performance of a three-phase induction motor 电压谐波对三相感应电动机电气和机械性能的影响
Ching-Yin Lee, Weijen Lee, Yen-Nien Wang, J. Gu
Due to the increasing requirement of precise control and equipment performance of a modern facility, the appearance of voltage harmonics in the power system has drawn great attention. Its impact on three-phase induction motors is one of the major concerns in industrial power systems. This paper uses a real load test to investigate the performances of a three-phase induction motor under different voltage distortion factors (VDF). The monitored qualities include motor efficiency, temperature rise, and torsional vibration. Adequacy and suggestions to the related regulations of harmonics control and limits are also presented.
由于现代设施对精确控制和设备性能的要求越来越高,电力系统中电压谐波的出现引起了人们的广泛关注。它对三相感应电动机的影响是工业电力系统中主要关注的问题之一。本文通过实负载试验,研究了三相感应电动机在不同电压失真系数(VDF)下的性能。监测的质量包括电机效率、温升和扭转振动。并对谐波控制和限制相关法规的充分性提出了建议。
{"title":"Effects of voltage harmonics on the electrical and mechanical performance of a three-phase induction motor","authors":"Ching-Yin Lee, Weijen Lee, Yen-Nien Wang, J. Gu","doi":"10.1109/ICPS.1998.692550","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692550","url":null,"abstract":"Due to the increasing requirement of precise control and equipment performance of a modern facility, the appearance of voltage harmonics in the power system has drawn great attention. Its impact on three-phase induction motors is one of the major concerns in industrial power systems. This paper uses a real load test to investigate the performances of a three-phase induction motor under different voltage distortion factors (VDF). The monitored qualities include motor efficiency, temperature rise, and torsional vibration. Adequacy and suggestions to the related regulations of harmonics control and limits are also presented.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116011925","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 41
Hybrid high-speed DC circuit breaker using charge-storage diode 采用电荷存储二极管的混合式高速直流断路器
R. Jungblut, R. Sittig
Arcless DC-circuit interruption with metallic contacts is accomplished by the hybrid combination of a mechanical switch, a sold state device (power diode) and a varistor. The load current is carried by the mechanical switch. Before opening the contacts, the diode is charged by a high current pulse in forward direction. When the contacts open the diode short-circuits the fault current in its reverse direction until the charge accumulated in the diode is depleted. By this time the contacts have to be separated to withstand the now fast increasing voltage. With the hybrid high-speed circuit breaker switching currents of 275 ampere at 1250 volts were achieved with delay times of 80 microseconds.
具有金属触点的无弧直流电路中断是通过机械开关、稳态器件(功率二极管)和压敏电阻的混合组合来实现的。负载电流由机械开关传送。在打开触点之前,二极管被正向的大电流脉冲充电。当触点打开时,二极管短路,故障电流向相反方向,直到二极管中积累的电荷耗尽。此时,触点必须分开以承受现在快速增加的电压。混合高速断路器在1250伏特下可实现275安培的开关电流,延迟时间为80微秒。
{"title":"Hybrid high-speed DC circuit breaker using charge-storage diode","authors":"R. Jungblut, R. Sittig","doi":"10.1109/ICPS.1998.692551","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692551","url":null,"abstract":"Arcless DC-circuit interruption with metallic contacts is accomplished by the hybrid combination of a mechanical switch, a sold state device (power diode) and a varistor. The load current is carried by the mechanical switch. Before opening the contacts, the diode is charged by a high current pulse in forward direction. When the contacts open the diode short-circuits the fault current in its reverse direction until the charge accumulated in the diode is depleted. By this time the contacts have to be separated to withstand the now fast increasing voltage. With the hybrid high-speed circuit breaker switching currents of 275 ampere at 1250 volts were achieved with delay times of 80 microseconds.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115548233","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Neutral grounding-nothing new-tral about it [power network protection] 中性点接地-无新意[电网保护]
P. Zavadivker
This paper addresses the technical issues associated with neutral grounding in low-voltage, solidly grounded, four-wire power systems. For these systems, the paper discusses several design configurations, including those backed up by a standby generator or arranged as a dual-feed, double-ended bus. The paper's main focus is on the compliance of these systems with the National Electrical Code. Specifically, the paper reviews the NEC requirements associated with the neutral conductor grounding and ground fault protection for these power systems.
本文论述了低压、固接地、四线制电力系统中性点接地的相关技术问题。对于这些系统,本文讨论了几种设计配置,包括由备用发电机备份或布置为双馈双端母线的系统。本文主要关注的是这些系统是否符合国家电气规范。具体来说,本文回顾了与这些电力系统的中性导体接地和接地故障保护相关的NEC要求。
{"title":"Neutral grounding-nothing new-tral about it [power network protection]","authors":"P. Zavadivker","doi":"10.1109/ICPS.1998.692555","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692555","url":null,"abstract":"This paper addresses the technical issues associated with neutral grounding in low-voltage, solidly grounded, four-wire power systems. For these systems, the paper discusses several design configurations, including those backed up by a standby generator or arranged as a dual-feed, double-ended bus. The paper's main focus is on the compliance of these systems with the National Electrical Code. Specifically, the paper reviews the NEC requirements associated with the neutral conductor grounding and ground fault protection for these power systems.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115219253","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Short-circuit currents to perform a protective device coordination study 对短路电流进行保护装置协调研究
H. Fleck, F.J. Mercede
There are two types of short-circuit studies of interest to the power engineer. The results of the first type are used to select the withstand and interrupting capabilities of switchgear; whereas, the results of the second type are used to properly select the settings of overcurrent protective devices. Oftentimes, the engineer is in possession of commercial software for the first type of short-circuit study. Thus, a natural question is whether its output can also be applied to the second type. The purpose of this paper is to address this question, in accordance with Chapter 4 of the IEEE Red Book, by comparing the two types of short-circuit studies. The basis for the comparison is the complex impedance network method. A sample industrial power system is used to clarify the findings.
电力工程师对两种类型的短路研究感兴趣。第一类的结果用于选择开关柜的耐压和中断能力;而第二类结果用于过流保护装置整定的正确选择。通常,工程师拥有用于第一种短路研究的商业软件。因此,一个自然的问题是,它的输出是否也可以应用于第二种类型。本文的目的是根据IEEE红皮书第4章,通过比较两种类型的短路研究来解决这个问题。比较的依据是复阻抗网络法。用一个工业电力系统样本来阐明研究结果。
{"title":"Short-circuit currents to perform a protective device coordination study","authors":"H. Fleck, F.J. Mercede","doi":"10.1109/ICPS.1998.692559","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692559","url":null,"abstract":"There are two types of short-circuit studies of interest to the power engineer. The results of the first type are used to select the withstand and interrupting capabilities of switchgear; whereas, the results of the second type are used to properly select the settings of overcurrent protective devices. Oftentimes, the engineer is in possession of commercial software for the first type of short-circuit study. Thus, a natural question is whether its output can also be applied to the second type. The purpose of this paper is to address this question, in accordance with Chapter 4 of the IEEE Red Book, by comparing the two types of short-circuit studies. The basis for the comparison is the complex impedance network method. A sample industrial power system is used to clarify the findings.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116924571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
The impact of system grounding practices on generator fault damage 系统接地措施对发电机故障损坏的影响
L. J. Powell
Industry has recently become sensitized to the problem of severe generator damage due to stator ground faults. To prevent this damage, it has been suggested that the practices employed for neutral grounding should be changed. This paper provides an analytical perspective on this problem and suggests that the real issue is the manner in which the neutral of the generator itself is grounded.
最近,工业界对定子接地故障造成发电机严重损坏的问题变得敏感起来。为了防止这种损害,有人建议应该改变中性点接地的做法。本文对这一问题进行了分析,认为真正的问题在于发电机本身的中性点接地方式。
{"title":"The impact of system grounding practices on generator fault damage","authors":"L. J. Powell","doi":"10.1109/ICPS.1998.692530","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692530","url":null,"abstract":"Industry has recently become sensitized to the problem of severe generator damage due to stator ground faults. To prevent this damage, it has been suggested that the practices employed for neutral grounding should be changed. This paper provides an analytical perspective on this problem and suggests that the real issue is the manner in which the neutral of the generator itself is grounded.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129065128","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 51
Static-digital overcurrent relays permit enhanced protection 静态数字过流继电器允许增强保护
B. Bailey, D. Jakominich
Multi-function static overcurrent relays employing digital technology have functionality that permits improved and expanded protection in many applications. While a relay is normally selected for the required overcurrent and ground fault protection, effective utilization of additional available functions can provide added security without significant additional cost. This paper describes an application for an oil refinery power system that uses directional overcurrent elements and reverse interlocking between the main, tie and feeder relays for a dual source-normally closed tie system. This scheme provides fast tripping for bus faults, which has several advantages over traditional bus differential relaying. This paper also describes a ground fault protection scheme to detect feeder grounds on a high resistance grounded system.
采用数字技术的多功能静态过流继电器具有在许多应用中允许改进和扩展保护的功能。虽然继电器通常用于所需的过流和接地故障保护,但有效利用额外的可用功能可以提供额外的安全性,而无需显著的额外成本。本文介绍了在某炼油厂电力系统中采用定向过流元件和主、联络线和馈线继电器之间反向联锁的双源常闭联络线系统的应用。该方案提供了对母线故障的快速脱扣,与传统的母线差动继电器相比具有许多优点。本文还介绍了一种检测高阻接地系统馈线接地的接地故障保护方案。
{"title":"Static-digital overcurrent relays permit enhanced protection","authors":"B. Bailey, D. Jakominich","doi":"10.1109/ICPS.1998.692529","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692529","url":null,"abstract":"Multi-function static overcurrent relays employing digital technology have functionality that permits improved and expanded protection in many applications. While a relay is normally selected for the required overcurrent and ground fault protection, effective utilization of additional available functions can provide added security without significant additional cost. This paper describes an application for an oil refinery power system that uses directional overcurrent elements and reverse interlocking between the main, tie and feeder relays for a dual source-normally closed tie system. This scheme provides fast tripping for bus faults, which has several advantages over traditional bus differential relaying. This paper also describes a ground fault protection scheme to detect feeder grounds on a high resistance grounded system.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131630034","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Applicability of co-generation equipment as a source of standby or emergency power 热电联产设备作为备用或应急电源的适用性
P. G. Cradinal
When a thunderstorm left a Houston (USA) research and development complex without power for several hours, it was suggested that an existing natural gas-fired cogeneration system be modified to provide backup power. This paper investigates the feasibility of upgrading the installation to meet standby power requirements. Included are required hardware modifications along with an overview of applicable electrical and life safety codes. Economic factors are presented which compare co-generation system modifications to other standby power alternatives.
当一场雷雨使休斯顿(美国)的一个研发中心停电数小时时,有人建议对现有的天然气热电联产系统进行改造,以提供备用电源。本文探讨了升级装置以满足备用电源要求的可行性。包括所需的硬件修改以及适用的电气和生命安全规范的概述。提出了将热电联产系统改造与其他备用电源替代方案进行比较的经济因素。
{"title":"Applicability of co-generation equipment as a source of standby or emergency power","authors":"P. G. Cradinal","doi":"10.1109/ICPS.1998.692536","DOIUrl":"https://doi.org/10.1109/ICPS.1998.692536","url":null,"abstract":"When a thunderstorm left a Houston (USA) research and development complex without power for several hours, it was suggested that an existing natural gas-fired cogeneration system be modified to provide backup power. This paper investigates the feasibility of upgrading the installation to meet standby power requirements. Included are required hardware modifications along with an overview of applicable electrical and life safety codes. Economic factors are presented which compare co-generation system modifications to other standby power alternatives.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134238355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1