Acceptable indoor air quality at reduced energy consumption for high-occupancy buildings with intermittent operation 间歇运行的高占用率建筑在降低能耗的情况下可接受的室内空气质量
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-04-13 DOI: 10.1080/00038628.2023.2199705
I. M. Budaiwi, M. Mohammed
In high-occupancy buildings with intermittent and short-occupancy events, occupants and their activities are the primary sources of contaminants, rendering continuous ventilation unnecessary for achieving acceptable indoor air quality (IAQ). Because the recommended ventilation rate constitutes a substantial percentage of the supply air, reducing or discontinuing ventilation during unoccupied periods saves significant energy. This study aims to assess the IAQ of high-occupancy buildings with different ventilation strategies and occupancy schemes to conserve energy using CONTAM (IAQ and ventilation analysis program) and Visual-DOE (energy analysis program). The results show that intermittently operating the ventilation 1 hour before occupancy saves 25% in the auditorium and 33% in the mosque compared to the continuous ventilation strategy. The intermittently operated strategy with ventilation 1 hour before occupancy also revealed an acceptable CO2 level (<1000ppm), while the Formaldehyde (HCHO) levels decreased with increasing ventilation rates, as humans’ contribution to the HCHO concentration indoors was insignificant.
在具有间歇性和短暂占用事件的高占用率建筑中,占用者及其活动是污染物的主要来源,因此不需要连续通风来实现可接受的室内空气质量(IAQ)。由于推荐的通风率占供应空气的很大比例,因此在未占用时段减少或停止通风可节省大量能源。本研究旨在使用CONTAM(室内空气质量和通风分析程序)和Visual DOE(能量分析程序)评估具有不同通风策略和占用方案的高占用率建筑的室内空气质量,以节约能源。结果表明,间歇运行通风1 与连续通风策略相比,在入住前一小时,礼堂节省了25%,清真寺节省了33%。具有通风1的间歇操作策略 入住前一小时也显示出可接受的二氧化碳水平(<1000ppm),而甲醛(HCHO)水平随着通风率的增加而降低,因为人类对室内HCHO浓度的贡献微不足道。
{"title":"Acceptable indoor air quality at reduced energy consumption for high-occupancy buildings with intermittent operation","authors":"I. M. Budaiwi, M. Mohammed","doi":"10.1080/00038628.2023.2199705","DOIUrl":"https://doi.org/10.1080/00038628.2023.2199705","url":null,"abstract":"In high-occupancy buildings with intermittent and short-occupancy events, occupants and their activities are the primary sources of contaminants, rendering continuous ventilation unnecessary for achieving acceptable indoor air quality (IAQ). Because the recommended ventilation rate constitutes a substantial percentage of the supply air, reducing or discontinuing ventilation during unoccupied periods saves significant energy. This study aims to assess the IAQ of high-occupancy buildings with different ventilation strategies and occupancy schemes to conserve energy using CONTAM (IAQ and ventilation analysis program) and Visual-DOE (energy analysis program). The results show that intermittently operating the ventilation 1 hour before occupancy saves 25% in the auditorium and 33% in the mosque compared to the continuous ventilation strategy. The intermittently operated strategy with ventilation 1 hour before occupancy also revealed an acceptable CO2 level (<1000ppm), while the Formaldehyde (HCHO) levels decreased with increasing ventilation rates, as humans’ contribution to the HCHO concentration indoors was insignificant.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46824066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design and fabrication of smooth poly-hypar timber gridshells 光滑聚超棒木材网格壳的设计与制造
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-04-03 DOI: 10.1080/00038628.2023.2192695
T. Cao, Alessandro Tellini, Zongshuai Wan
{"title":"Design and fabrication of smooth poly-hypar timber gridshells","authors":"T. Cao, Alessandro Tellini, Zongshuai Wan","doi":"10.1080/00038628.2023.2192695","DOIUrl":"https://doi.org/10.1080/00038628.2023.2192695","url":null,"abstract":"","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48878529","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Data-driven approach to prioritize residential buildings’ retrofits in cold climates using smart thermostat data 使用智能恒温器数据优先考虑寒冷气候下住宅楼改造的数据驱动方法
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-03-31 DOI: 10.1080/00038628.2023.2193164
A. Doma, M. Ouf
At least 65% of existing residential buildings will still be in use by 2050, thus retrofitting existing buildings is critical to reducing energy consumption. However, prioritizing building retrofits typically requires a thorough evaluation of their thermal performance, which can be cost-prohibitive, especially on a large scale. To this end, this study presents a data-driven framework to target buildings for retrofits using smart thermostat data. To validate the framework, it was applied to 60,000 homes across North America using four years of real-time measurements. First, grey-box modelling approaches were used to estimate the thermal time constant for each home. Homes were then clustered according to their estimated values and for each cluster, the priority of retrofit was ranked. Finally, a classification model was developed to predict the priority of retrofit. Using a large sample size, the results can be used to prioritize buildings for retrofits when limited information is available. HIGHLIGHTS Thermostat data from over 60,000 houses were used to estimate their thermal performance. Two grey-box methods to estimate a building's thermal time constant (RC value) were compared. The estimated time constant values were used to cluster houses based on thermal performance. A classification model was developed to prioritize retrofits for each house based on its attributes.
到2050年,至少有65%的现有住宅建筑仍在使用,因此对现有建筑进行改造对于减少能源消耗至关重要。然而,优先考虑建筑改造通常需要对其热性能进行彻底的评估,这可能会导致成本过高,特别是在大规模的情况下。为此,本研究提出了一个数据驱动的框架,利用智能恒温器数据对建筑物进行改造。为了验证该框架,该框架应用于北美60,000个家庭,使用了四年的实时测量。首先,使用灰盒建模方法估计每个家庭的热时间常数。然后根据其估计值对房屋进行分组,并对每个分组进行改造的优先级排序。最后,建立了一个分类模型来预测改造的优先级。使用大样本量,结果可用于在信息有限的情况下优先考虑建筑物的改造。来自6万多所房屋的恒温器数据用于估计其热性能。比较了估算建筑热时间常数(RC值)的两种灰盒法。估计的时间常数值被用于根据热性能对房屋进行分类。开发了一个分类模型,根据每个房屋的属性优先考虑改造。
{"title":"Data-driven approach to prioritize residential buildings’ retrofits in cold climates using smart thermostat data","authors":"A. Doma, M. Ouf","doi":"10.1080/00038628.2023.2193164","DOIUrl":"https://doi.org/10.1080/00038628.2023.2193164","url":null,"abstract":"At least 65% of existing residential buildings will still be in use by 2050, thus retrofitting existing buildings is critical to reducing energy consumption. However, prioritizing building retrofits typically requires a thorough evaluation of their thermal performance, which can be cost-prohibitive, especially on a large scale. To this end, this study presents a data-driven framework to target buildings for retrofits using smart thermostat data. To validate the framework, it was applied to 60,000 homes across North America using four years of real-time measurements. First, grey-box modelling approaches were used to estimate the thermal time constant for each home. Homes were then clustered according to their estimated values and for each cluster, the priority of retrofit was ranked. Finally, a classification model was developed to predict the priority of retrofit. Using a large sample size, the results can be used to prioritize buildings for retrofits when limited information is available. HIGHLIGHTS Thermostat data from over 60,000 houses were used to estimate their thermal performance. Two grey-box methods to estimate a building's thermal time constant (RC value) were compared. The estimated time constant values were used to cluster houses based on thermal performance. A classification model was developed to prioritize retrofits for each house based on its attributes.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45143894","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A review of residential building archetypes and their applications to study building energy consumption 住宅建筑原型及其在建筑能耗研究中的应用综述
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-03-28 DOI: 10.1080/00038628.2023.2193167
Bibhu Kalyan Nayak, S. K. Sansaniwal, Jyotirmay Mathur, T. Chandra, V. Garg, Rajat Gupta
In developing economies, residential energy consumption patterns have rapidly transformed with better energy access and service quality. Unlike other building types, residential buildings are more complex due to wide variations in their consumption patterns influenced by various factors. Researchers have characterised residential building stock based on distinct building archetypes. This paper presents a comprehensive review of relevant published research focusing on the classification of residential buildings based on their energy consumption. This review also focuses on residential archetype studies in the context of building science. The methodologies adopted by different researchers to characterise the energy use of residential building stock using an archetypal approach at different spatial scales (building to city scale and local to national scale) have been critically reviewed in this study. The paper will provide the researchers with a holistic understanding of the current directions and magnitude of ongoing research in this domain.
在发展中经济体,居民能源消费模式迅速转变,能源获取和服务质量得到改善。与其他类型的建筑不同,住宅建筑由于受到各种因素的影响,其消费模式存在很大差异,因此更为复杂。研究人员根据不同的建筑原型来描述住宅建筑。本文对住宅建筑能耗分类的相关研究进行了综述。这篇综述也着重于建筑科学背景下的住宅原型研究。在本研究中,不同的研究人员采用不同空间尺度(建筑到城市尺度和地方到国家尺度)的原型方法来描述住宅建筑的能源使用特征。本文将为研究人员提供对该领域正在进行的研究的当前方向和规模的整体理解。
{"title":"A review of residential building archetypes and their applications to study building energy consumption","authors":"Bibhu Kalyan Nayak, S. K. Sansaniwal, Jyotirmay Mathur, T. Chandra, V. Garg, Rajat Gupta","doi":"10.1080/00038628.2023.2193167","DOIUrl":"https://doi.org/10.1080/00038628.2023.2193167","url":null,"abstract":"In developing economies, residential energy consumption patterns have rapidly transformed with better energy access and service quality. Unlike other building types, residential buildings are more complex due to wide variations in their consumption patterns influenced by various factors. Researchers have characterised residential building stock based on distinct building archetypes. This paper presents a comprehensive review of relevant published research focusing on the classification of residential buildings based on their energy consumption. This review also focuses on residential archetype studies in the context of building science. The methodologies adopted by different researchers to characterise the energy use of residential building stock using an archetypal approach at different spatial scales (building to city scale and local to national scale) have been critically reviewed in this study. The paper will provide the researchers with a holistic understanding of the current directions and magnitude of ongoing research in this domain.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48788822","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of winter natural ventilation on thermal environment of university dormitories under central heating mode in severe cold regions of China 中国严寒地区集中供暖模式下冬季自然通风对大学宿舍热环境的影响
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-03-24 DOI: 10.1080/00038628.2023.2192192
Huiying Zhang, Zheming Liu
The indoor thermal environment impacts people’s health, while it can be adjusted by natural ventilation. However, studies on the effects of winter natural ventilation on the thermal environment in severe cold regions are minimal. Through field measurements in university dormitories in winter in Shenyang, China, this study explored, under the central heating mode, the thermal environment differences in different orientations of the dormitory and its different indoor positions under natural ventilation and the influence of window opening area and duration on the thermal environment. The results show that under winter natural ventilation, the air temperature, mean radiation temperature, and adaptive predicted mean vote (APMV) of dormitories facing different orientations were mainly affected by the direct solar radiation reception. When the ventilation duration reached 15mins, with the ratio of window opening area to a ground area of 0.05, 0.11, and 0.16, the APMV decreased by about 0.35, 0.5, and 1, respectively.
室内热环境影响人体健康,可通过自然通风进行调节。然而,关于冬季自然通风对严寒地区热环境影响的研究很少。本研究通过对中国沈阳地区冬季高校宿舍的实地测量,探讨了集中供暖方式下,宿舍不同朝向和不同室内位置在自然通风条件下的热环境差异,以及开窗面积和开窗时间对热环境的影响。结果表明:冬季自然通风条件下,不同朝向宿舍的空气温度、平均辐射温度和自适应预测平均投票值(APMV)主要受太阳直接辐射接收的影响;当通风时间达到15min时,开窗面积与地面面积之比分别为0.05、0.11和0.16,APMV分别下降约0.35、0.5和1。
{"title":"Influence of winter natural ventilation on thermal environment of university dormitories under central heating mode in severe cold regions of China","authors":"Huiying Zhang, Zheming Liu","doi":"10.1080/00038628.2023.2192192","DOIUrl":"https://doi.org/10.1080/00038628.2023.2192192","url":null,"abstract":"The indoor thermal environment impacts people’s health, while it can be adjusted by natural ventilation. However, studies on the effects of winter natural ventilation on the thermal environment in severe cold regions are minimal. Through field measurements in university dormitories in winter in Shenyang, China, this study explored, under the central heating mode, the thermal environment differences in different orientations of the dormitory and its different indoor positions under natural ventilation and the influence of window opening area and duration on the thermal environment. The results show that under winter natural ventilation, the air temperature, mean radiation temperature, and adaptive predicted mean vote (APMV) of dormitories facing different orientations were mainly affected by the direct solar radiation reception. When the ventilation duration reached 15mins, with the ratio of window opening area to a ground area of 0.05, 0.11, and 0.16, the APMV decreased by about 0.35, 0.5, and 1, respectively.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46698116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A kinetic origami surfaces methodology 一种动力学折纸表面方法
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-03-12 DOI: 10.1080/00038628.2023.2182270
F. Osório, Alexandra Paio, Sancho Oliveira
{"title":"A kinetic origami surfaces methodology","authors":"F. Osório, Alexandra Paio, Sancho Oliveira","doi":"10.1080/00038628.2023.2182270","DOIUrl":"https://doi.org/10.1080/00038628.2023.2182270","url":null,"abstract":"","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48950642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Control in healthcare interiors: the staff’s perspective 医疗内部控制:员工视角
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-03-02 DOI: 10.1080/00038628.2023.2182269
Gülnur Ballice, Ç. Çetin, Eda Paykoç Özçelik, Zeynep Tuna Ultav
As two of the most stressful professions, doctors and nurses work intensively in direct contact with patients. However, there has been little research into their perception of and satisfaction with healthcare interiors. To fill this gap in the literature, this study evaluated the working, resting, and dining spaces of healthcare staff in terms of control. Specifically, privacy, boundary and territory, and environmental control were analyzed in four state hospitals as case studies. Following a literature review, observations, semi-structured interviews, and surveys were conducted with doctors and nurses from the four hospitals in 2017. The findings showed that controlling privacy, boundaries, and environmental control elements like natural and artificial lighting, noise and odour were important for the participants. This indicates a need to ensure privacy and boundaries more effectively through separate spaces and furniture while noise and odour should also be given more attention.
作为压力最大的两个职业,医生和护士在与患者直接接触的情况下工作密集。然而,很少有研究表明他们对医疗保健内部的感知和满意度。为了填补文献中的这一空白,本研究从控制的角度评估了医护人员的工作、休息和用餐空间。具体来说,隐私、边界和领土以及环境控制作为案例研究在四家州立医院进行了分析。在文献综述之后,2017年对四家医院的医生和护士进行了观察、半结构化访谈和调查。研究结果表明,控制隐私、边界和环境控制因素,如自然和人工照明、噪音和气味,对参与者来说很重要。这表明需要通过单独的空间和家具更有效地确保隐私和边界,同时也应该更多地关注噪音和气味。
{"title":"Control in healthcare interiors: the staff’s perspective","authors":"Gülnur Ballice, Ç. Çetin, Eda Paykoç Özçelik, Zeynep Tuna Ultav","doi":"10.1080/00038628.2023.2182269","DOIUrl":"https://doi.org/10.1080/00038628.2023.2182269","url":null,"abstract":"As two of the most stressful professions, doctors and nurses work intensively in direct contact with patients. However, there has been little research into their perception of and satisfaction with healthcare interiors. To fill this gap in the literature, this study evaluated the working, resting, and dining spaces of healthcare staff in terms of control. Specifically, privacy, boundary and territory, and environmental control were analyzed in four state hospitals as case studies. Following a literature review, observations, semi-structured interviews, and surveys were conducted with doctors and nurses from the four hospitals in 2017. The findings showed that controlling privacy, boundaries, and environmental control elements like natural and artificial lighting, noise and odour were important for the participants. This indicates a need to ensure privacy and boundaries more effectively through separate spaces and furniture while noise and odour should also be given more attention.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49221028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The impact of service core reduction in supertall buildings: a study on structural design, embodied carbon, and leasable floor area 超高层建筑服务核心减少的影响:结构设计、隐含碳和可出租建筑面积的研究
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-02-28 DOI: 10.1080/00038628.2023.2182271
Beste Fakıoğlu Gedik, B. Ay
Optimizing the building core is a fundamental goal in tall building design The area dedicated to elevators, which are among the most area-consuming elements in the core, might be considerably reduced with recent technological advancements. This study investigates the trade-offs of core reduction resulting from the elevator footprint decrease in supertall buildings since the core usually serves as a significant member of the structural system. An analytical model with an outriggered frame system representative of supertall office buildings is generated, and then a second model is reproduced by reducing its core. Structurally modified reduced core models satisfying lateral drift limits are produced and evaluated in terms of architectural, economic, and environmental aspects. The results showed that a gain in the leasable area is possible but at the expense of higher cumulative embodied carbon and material consumption. These outcomes provide a comprehensive perspective for structural design considerations, particularly core optimization for tall buildings with outriggers.
优化建筑核心是高层建筑设计的一个基本目标。随着最近的技术进步,电梯专用面积可能会大大减少,电梯是核心中最消耗面积的元素之一。本研究调查了超高层建筑中电梯占地面积减少导致的核心减少的权衡,因为核心通常是结构系统的重要组成部分。建立了一个以超高层办公楼为代表的外伸框架系统的分析模型,然后通过减少其核心来复制第二个模型。从建筑、经济和环境方面产生并评估了满足横向漂移限制的结构修改的缩芯模型。结果表明,可出租区域的收益是可能的,但代价是更高的累积内含碳和材料消耗。这些结果为结构设计考虑提供了一个全面的视角,特别是带有外伸支架的高层建筑的核心优化。
{"title":"The impact of service core reduction in supertall buildings: a study on structural design, embodied carbon, and leasable floor area","authors":"Beste Fakıoğlu Gedik, B. Ay","doi":"10.1080/00038628.2023.2182271","DOIUrl":"https://doi.org/10.1080/00038628.2023.2182271","url":null,"abstract":"Optimizing the building core is a fundamental goal in tall building design The area dedicated to elevators, which are among the most area-consuming elements in the core, might be considerably reduced with recent technological advancements. This study investigates the trade-offs of core reduction resulting from the elevator footprint decrease in supertall buildings since the core usually serves as a significant member of the structural system. An analytical model with an outriggered frame system representative of supertall office buildings is generated, and then a second model is reproduced by reducing its core. Structurally modified reduced core models satisfying lateral drift limits are produced and evaluated in terms of architectural, economic, and environmental aspects. The results showed that a gain in the leasable area is possible but at the expense of higher cumulative embodied carbon and material consumption. These outcomes provide a comprehensive perspective for structural design considerations, particularly core optimization for tall buildings with outriggers.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46155697","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A decision-making framework to prioritize existing buildings for adaptive reuse with a case study of school buildings in Guilan, Iran 优先考虑现有建筑进行适应性再利用的决策框架——以伊朗吉兰的学校建筑为例
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-02-10 DOI: 10.1080/00038628.2023.2174067
M. Pourebrahimi, Amir Reza Karimi Azeri, Mojtaba Pour Ahmadi
The paper seeks to outline a framework to prioritize existing buildings for adaptive reuse. Twenty-nine schools were selected and investigated to determine their priority for adaptive reuse. By evaluating obsolescence and calculating the useful life of the buildings, their potential for reuse was identified using Adaptive Reuse Potential (ARP) model. According to the reuse potential and best time for reuse intervention, these projects were prioritized. By determining the most important obsolescence types and setting priorities among them according to their impact on reducing the buildings’ useful life, different strategies to mitigate/avoid each obsolescence have been discussed. The results show that functional, technological and physical obsolescence are the most important types of obsolescence respectively. Also, according to the results the average effective useful life of all case studies is 54%. Therefore, with the persistenceof the current conditions, only about half of the expected life of the cases will be utilized.
该文件试图概述一个框架,以优先考虑现有建筑的适应性再利用。选择并调查了29所学校,以确定其适应性再利用的优先顺序。通过评估过时情况和计算建筑物的使用寿命,使用自适应再利用潜力(ARP)模型来识别其再利用潜力。根据复用潜力和复用干预的最佳时间,对这些项目进行了优先排序。通过确定最重要的报废类型,并根据其对缩短建筑物使用寿命的影响确定优先级,讨论了缓解/避免每次报废的不同策略。结果表明,功能过时、技术过时和物理过时分别是最重要的过时类型。此外,根据研究结果,所有案例研究的平均有效使用寿命为54%。因此,在目前条件持续的情况下,只有大约一半的案件预期寿命会被利用。
{"title":"A decision-making framework to prioritize existing buildings for adaptive reuse with a case study of school buildings in Guilan, Iran","authors":"M. Pourebrahimi, Amir Reza Karimi Azeri, Mojtaba Pour Ahmadi","doi":"10.1080/00038628.2023.2174067","DOIUrl":"https://doi.org/10.1080/00038628.2023.2174067","url":null,"abstract":"The paper seeks to outline a framework to prioritize existing buildings for adaptive reuse. Twenty-nine schools were selected and investigated to determine their priority for adaptive reuse. By evaluating obsolescence and calculating the useful life of the buildings, their potential for reuse was identified using Adaptive Reuse Potential (ARP) model. According to the reuse potential and best time for reuse intervention, these projects were prioritized. By determining the most important obsolescence types and setting priorities among them according to their impact on reducing the buildings’ useful life, different strategies to mitigate/avoid each obsolescence have been discussed. The results show that functional, technological and physical obsolescence are the most important types of obsolescence respectively. Also, according to the results the average effective useful life of all case studies is 54%. Therefore, with the persistenceof the current conditions, only about half of the expected life of the cases will be utilized.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41750581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Wind induced pressures on a large low-sloped gable roof building with parapet 风对带有护墙的大型低斜山墙屋顶建筑产生的压力
IF 2.3 3区 艺术学 Q1 Engineering Pub Date : 2023-02-06 DOI: 10.1080/00038628.2023.2174066
A. Aly, M. Thomas
This paper experimentally investigates how parapets with varying heights can alter the flow pattern around a large aspect-ratio low-sloped gable roof building. We examine the benefits and challenges of existing methods and utilize an open-jet wind test section, to accurately simulate real-world atmospheric boundary layer conditions. A model of a low-rise building was fitted with solid parapets of varying heights and tested in a comparative study to understand their impact on roof pressures. The study compares the standard approach to the experimental results and suggests improvements to wind zones and pressure coefficients. The parapet of fourteen percent of the building height is the most efficient at reducing mean, peak, and area-averaged wind loads compared to other sizes. However, the standard provisions underestimate roof pressures for components and cladding design.
本文通过实验研究了不同高度的护墙如何改变大纵横比低坡山墙屋顶建筑周围的流动模式。我们研究了现有方法的优点和挑战,并利用开放式喷气风试验段来准确模拟真实世界的大气边界层条件。一个低层建筑模型安装了不同高度的实心护墙,并在一项比较研究中进行了测试,以了解它们对屋顶压力的影响。该研究将标准方法与实验结果进行了比较,并建议改进风区和压力系数。与其他尺寸相比,建筑高度14%的女儿墙在降低平均、峰值和面积平均风荷载方面最有效。然而,标准规定低估了构件和覆层设计的屋顶压力。
{"title":"Wind induced pressures on a large low-sloped gable roof building with parapet","authors":"A. Aly, M. Thomas","doi":"10.1080/00038628.2023.2174066","DOIUrl":"https://doi.org/10.1080/00038628.2023.2174066","url":null,"abstract":"This paper experimentally investigates how parapets with varying heights can alter the flow pattern around a large aspect-ratio low-sloped gable roof building. We examine the benefits and challenges of existing methods and utilize an open-jet wind test section, to accurately simulate real-world atmospheric boundary layer conditions. A model of a low-rise building was fitted with solid parapets of varying heights and tested in a comparative study to understand their impact on roof pressures. The study compares the standard approach to the experimental results and suggests improvements to wind zones and pressure coefficients. The parapet of fourteen percent of the building height is the most efficient at reducing mean, peak, and area-averaged wind loads compared to other sizes. However, the standard provisions underestimate roof pressures for components and cladding design.","PeriodicalId":47295,"journal":{"name":"Architectural Science Review","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41767401","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Architectural Science Review
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1