首页 > 最新文献

International Journal of Computerized Dentistry最新文献

英文 中文
Interproximal tooth cleaning operated by a tactile robot. An in vitro analysis. 由触觉机器人操作的近牙间清洁。体外分析。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-10-15 DOI: 10.3290/j.ijcd.b4224851
Loraine Pieper, Meike Stiesch, Lukas Eich, Sami Haddadin, Jasmin Grischke

Aim: New technologies such as tactile robots and artificial intelligence (AI) are finding their way into clinical practice in dentistry and could contribute to the improvement of oral health care in the future. The hypothesis of the present in vitro pilot study trial was that a collaborative tactile robot programmed by a dental student could remove interproximal artificial plaque as effectively as a human operator.

Materials and methods: Model teeth were fully covered with artificial plaque and set into phantom jaws. First, a robot was programmed by a dental student to perform interproximal cleaning with an interproximal brush. Second, the teeth were covered with artificial plaque again, and the dental student performed the interproximal cleaning manually. Both experiments were repeated five times. Residual plaque was measured with binary pictures. Surface coverage was reported, and the comparison of methods was performed with significance defined at α = 0.05.

Results: No statistically significant difference was found in the cleaning result between the robot and the human operator.

Conclusion: The results of the present in vitro pilot study indicate that a tactile robot with integrated AI programmed by a dental student can perform interproximal cleaning as effectively as a dental student.

Practical implications: In the future, the use of robot assistants to support oral hygiene, eg, in patients with reduced motor skills or impaired vision, should be fur ther investigated.

目的:触觉机器人和人工智能等新技术即将进入牙科临床实践,并可能在未来为改善口腔保健做出贡献。在这项研究中,我们假设在体外试验中,由牙科学生编程的协作式触觉机器人能像人类操作员一样有效地清除近端间的人造牙菌斑:材料和方法:模型牙齿被人工牙菌斑完全覆盖,并镶嵌在模型颌骨上。首先,由一名牙科学生对机器人进行编程,让其使用近端间刷进行近端间清洁。其次,再次用人造牙菌斑覆盖牙齿,由牙科学生手动进行近端间清洁。两项实验均重复五次。残留牙菌斑用二进制图片测量。报告表面覆盖率,并对各种方法进行比较,显著性定义为 a= 0.05:结果:机器人和人类操作员的清洁效果没有明显的统计学差异:这项体外试验研究的结果表明,由牙科学生编程的集成了人工智能的触觉机器人可以像牙科学生一样有效地进行近端间清洁。实际意义:未来,可能会进一步研究使用机器人助手来支持口腔卫生,例如对运动能力下降或视力受损的患者。
{"title":"Interproximal tooth cleaning operated by a tactile robot. An in vitro analysis.","authors":"Loraine Pieper, Meike Stiesch, Lukas Eich, Sami Haddadin, Jasmin Grischke","doi":"10.3290/j.ijcd.b4224851","DOIUrl":"10.3290/j.ijcd.b4224851","url":null,"abstract":"<p><strong>Aim: </strong>New technologies such as tactile robots and artificial intelligence (AI) are finding their way into clinical practice in dentistry and could contribute to the improvement of oral health care in the future. The hypothesis of the present in vitro pilot study trial was that a collaborative tactile robot programmed by a dental student could remove interproximal artificial plaque as effectively as a human operator.</p><p><strong>Materials and methods: </strong>Model teeth were fully covered with artificial plaque and set into phantom jaws. First, a robot was programmed by a dental student to perform interproximal cleaning with an interproximal brush. Second, the teeth were covered with artificial plaque again, and the dental student performed the interproximal cleaning manually. Both experiments were repeated five times. Residual plaque was measured with binary pictures. Surface coverage was reported, and the comparison of methods was performed with significance defined at α &#61; 0.05.</p><p><strong>Results: </strong>No statistically significant difference was found in the cleaning result between the robot and the human operator.</p><p><strong>Conclusion: </strong>The results of the present in vitro pilot study indicate that a tactile robot with integrated AI programmed by a dental student can perform interproximal cleaning as effectively as a dental student.</p><p><strong>Practical implications: </strong>In the future, the use of robot assistants to support oral hygiene, eg, in patients with reduced motor skills or impaired vision, should be fur ther investigated.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"251-258"},"PeriodicalIF":1.8,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9847187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of different sintering procedures on marginal and internal fit, color, and fracture load of monolithic zirconia fixed partial prostheses. 不同烧结程序对整体氧化锆固定局部义齿边缘和内部密合度、颜色以及断裂负荷的影响
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-10-15 DOI: 10.3290/j.ijcd.b5114621
Ravza Eraslan, Bahar Sayin Sahin, Haydar Albayrak, Mustafa Ayata, Ozan Temizkanli

Aim: The aim of the present in vitro study was to investigate the effects of different sintering procedures on the fit, color parameters, and fracture load of monolithic fixed partial prostheses (FPPs).

Materials and methods: A metal master model was scanned and FPPs were designed. Groups were created by fabricating FPPs using four different sintering procedures (n = 10): Prettau-Standard (PST); Prettau-Slow (PSL); Ice-Speed (ISP); Ice-Standard (IST). PST-PSL (Group P; N = 20) and ISP-IST (Group I; N = 20) were colored with different coloring liquids. The marginal and internal fit were measured using the silicone replica method. CIELAB values of the samples were measured using a spectrophotometer. Then, for each sample, the die was obtained from polymethyl methacrylate. The specimens were cemented into dies and tested in a universal testing machine for fracture load. One-way ANOVA was performed to assess the effect of the sintering procedure on the marginal and internal fit; fracture load; and ∆E00, ∆L', ∆C', and ∆H' values of the FPPs.

Results: The PSL and PST groups showed significantly smaller internal and marginal fit values compared with the ISP group. Additionally, the internal fit values of the IST group were significantly higher than those of Group P. Sintering time reduction led to a decrease in ∆E00 values. Fracture load values were not statistically significantly affected by the different sintering procedures for both brands.

Conclusion: Different sintering procedures did not have a clinically significant effect on fit and fracture load. Different sintering procedures were found to have an impact on the color change of monolithic zirconia restorations.

目的:本体外研究旨在探讨不同烧结程序对整体式固定局部义齿的密合度、颜色参数和断裂负荷的影响:扫描金属模型并设计固定部分修复体。使用四种不同的烧结程序(Prettau-Standard (PST)、Prettau-Slow (PSL)、Ice-Speed (IS)、Ice-Standard (IST),n=10)制作固定部分义齿,并将其分为四组。PST-PSL(P 组,N=20)和 IS-IST(I 组,N=20)用不同的着色液着色。采用硅胶复型法测量边缘和内部配合度。使用分光光度计测量样品的 CIELAB 值。然后,用聚甲基丙烯酸甲酯为每个试样制作模具。将试样粘合到模具中,并在万能试验机上进行断裂载荷测试。进行单因素方差分析以评估烧结程序对固定部分义齿的边缘和内部密合度、断裂载荷、∆E00、∆L'、∆C'和∆H'值的影响:与 IS 组相比,PSL 组和 PST 组的内部密合度和边缘密合度明显较小。此外,IST 组的内部密合度值明显高于 Prettau 组。烧结时间的缩短导致了 ∆E00 值的下降。两种品牌的不同烧结程序对断裂载荷值没有明显的统计学影响:结论:不同的烧结程序对贴合度和断裂载荷没有明显的临床影响。结论:不同的烧结程序对密合度和断裂载荷没有明显的临床影响,但不同的烧结程序对整体氧化锆修复体的颜色变化有影响。
{"title":"Effect of different sintering procedures on marginal and internal fit, color, and fracture load of monolithic zirconia fixed partial prostheses.","authors":"Ravza Eraslan, Bahar Sayin Sahin, Haydar Albayrak, Mustafa Ayata, Ozan Temizkanli","doi":"10.3290/j.ijcd.b5114621","DOIUrl":"10.3290/j.ijcd.b5114621","url":null,"abstract":"<p><strong>Aim: </strong>The aim of the present in vitro study was to investigate the effects of different sintering procedures on the fit, color parameters, and fracture load of monolithic fixed partial prostheses (FPPs).</p><p><strong>Materials and methods: </strong>A metal master model was scanned and FPPs were designed. Groups were created by fabricating FPPs using four different sintering procedures (n &#61; 10): Prettau-Standard (PST); Prettau-Slow (PSL); Ice-Speed (ISP); Ice-Standard (IST). PST-PSL (Group P; N &#61; 20) and ISP-IST (Group I; N &#61; 20) were colored with different coloring liquids. The marginal and internal fit were measured using the silicone replica method. CIELAB values of the samples were measured using a spectrophotometer. Then, for each sample, the die was obtained from polymethyl methacrylate. The specimens were cemented into dies and tested in a universal testing machine for fracture load. One-way ANOVA was performed to assess the effect of the sintering procedure on the marginal and internal fit; fracture load; and ∆E00, ∆L', ∆C', and ∆H' values of the FPPs.</p><p><strong>Results: </strong>The PSL and PST groups showed significantly smaller internal and marginal fit values compared with the ISP group. Additionally, the internal fit values of the IST group were significantly higher than those of Group P. Sintering time reduction led to a decrease in ∆E00 values. Fracture load values were not statistically significantly affected by the different sintering procedures for both brands.</p><p><strong>Conclusion: </strong>Different sintering procedures did not have a clinically significant effect on fit and fracture load. Different sintering procedures were found to have an impact on the color change of monolithic zirconia restorations.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"281-290"},"PeriodicalIF":1.8,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140186010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Abstracts der Beiträge für die Jahrestagung der Sektion Informatik der DGCZ]. [DGCZ计算机科学分会年会论文摘要]。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-10-15 DOI: 10.3290/j.ijcd.b5786132
Maximiliane Schlenz
{"title":"[Abstracts der Beiträge für die Jahrestagung der Sektion Informatik der DGCZ].","authors":"Maximiliane Schlenz","doi":"10.3290/j.ijcd.b5786132","DOIUrl":"https://doi.org/10.3290/j.ijcd.b5786132","url":null,"abstract":"","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"27 3","pages":"305-310"},"PeriodicalIF":1.8,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142478204","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accuracy of imaging software usable in clinical settings for 3D rendering of tooth structures. 可用于临床的牙齿结构三维渲染成像软件的准确性。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-10-15 DOI: 10.3290/j.ijcd.b4140897
Vincenzo Ronsivalle, Piero Venezia, Marco Migliorati, Cristina Grippaudo, Ersilia Barbato, Ludovica Nucci, Gaetano Isola, Rosalia Leonardi, Antonino Lo Giudice

Aim: The aim of the present study was to evaluate the segmentation accuracy of the dentition by testing four open-source semi-automatic software programs.

Materials and methods: Twenty CBCT scans were selected to perform semi-automatic segmentation of the maxillary and mandibular dentition. The software programs tested were InVesalius, ITK-SNAP, 3D Slicer, and Seg3D. In addition, each tooth model was manually segmented using Mimics software; this was set as the gold standard (GS) reference of the investigation. A specific 3D imaging technology was used to perform the superimposition between the tooth models obtained with the semi-automatic software and the GS model as well as to perform the surface-to-surface matching analysis. The accuracy of semi-automatic segmentation was evaluated, calculating the volumetric mean differences (mean bias and limits of agreement) and the percentage of matching of the tooth models compared with the manual segmentation (GS). Qualitative assessments were performed using color-coded maps. All data were statistically analyzed to perform comparisons between the investigated software programs.

Results: Statistically significant differences were found in the volumetric and matching percentage data (P 0.05). InVesalius was the most accurate software program for 3D rendering of the dentition, with a volumetric bias (Mimics software) ranging from 4.59 to 85.79 mm3, while ITK-SNAP showed the highest volumetric bias, ranging from 30.22 to 319.83 mm3. The mismatched area was mainly located at the radicular tooth region. The volumetric data showed excellent inter-software reliability, with coefficient values ranging from 0.951 to 0.997.

Conclusion: Different semi-automatic software algorithms could generate different patterns of inaccuracy error in the segmentation of teeth.

目的:本研究的目的是评估四款免费半自动软件的牙列分割准确性:共选择了 20 台锥形束计算机断层扫描(CBCT)对上颌和下颌牙体进行半自动分割。测试的软件包括 Invesalius、ITK-Snap、3D Slicer 和 Seg3D。每个牙齿模型也都经过手动分割(Mimics 软件),并设定为调查的金标准(GS)参照物。使用特定的三维成像技术将半自动软件获得的牙齿模型与金标准模型进行叠加,并进行面与面的匹配分析。半自动分割的准确性是通过计算与人工分割(GS)相比的体积平均差异(平均偏差和一致性限制)以及牙齿模型的匹配百分比来评估的。使用彩色编码图进行定性评估。对所有数据进行统计分析,以进行软件比较:结果:在体积和匹配百分比数据上发现了明显的统计学差异(P < 0.05)。Invesalius 是最准确的牙列三维渲染软件,其体积偏差(Mimics)从 4.59 mm3 到 85.79 mm3 不等;而 ITK-SNAP 的体积偏差更大,从 30.22 mm3 到 319.83 mm3 不等。不匹配区域主要位于牙齿的根状区。体积数据显示出软件间极佳的可靠性,系数值从 0,951 到 0,997 不等:结论:不同的半自动软件算法在分割牙齿时会产生不同的误差模式。
{"title":"Accuracy of imaging software usable in clinical settings for 3D rendering of tooth structures.","authors":"Vincenzo Ronsivalle, Piero Venezia, Marco Migliorati, Cristina Grippaudo, Ersilia Barbato, Ludovica Nucci, Gaetano Isola, Rosalia Leonardi, Antonino Lo Giudice","doi":"10.3290/j.ijcd.b4140897","DOIUrl":"10.3290/j.ijcd.b4140897","url":null,"abstract":"<p><strong>Aim: </strong>The aim of the present study was to evaluate the segmentation accuracy of the dentition by testing four open-source semi-automatic software programs.</p><p><strong>Materials and methods: </strong>Twenty CBCT scans were selected to perform semi-automatic segmentation of the maxillary and mandibular dentition. The software programs tested were InVesalius, ITK-SNAP, 3D Slicer, and Seg3D. In addition, each tooth model was manually segmented using Mimics software; this was set as the gold standard (GS) reference of the investigation. A specific 3D imaging technology was used to perform the superimposition between the tooth models obtained with the semi-automatic software and the GS model as well as to perform the surface-to-surface matching analysis. The accuracy of semi-automatic segmentation was evaluated, calculating the volumetric mean differences (mean bias and limits of agreement) and the percentage of matching of the tooth models compared with the manual segmentation (GS). Qualitative assessments were performed using color-coded maps. All data were statistically analyzed to perform comparisons between the investigated software programs.</p><p><strong>Results: </strong>Statistically significant differences were found in the volumetric and matching percentage data (P 0.05). InVesalius was the most accurate software program for 3D rendering of the dentition, with a volumetric bias (Mimics software) ranging from 4.59 to 85.79 mm3, while ITK-SNAP showed the highest volumetric bias, ranging from 30.22 to 319.83 mm3. The mismatched area was mainly located at the radicular tooth region. The volumetric data showed excellent inter-software reliability, with coefficient values ranging from 0.951 to 0.997.</p><p><strong>Conclusion: </strong>Different semi-automatic software algorithms could generate different patterns of inaccuracy error in the segmentation of teeth.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"235-250"},"PeriodicalIF":1.8,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9636820","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Students and teachers. 学生和教师。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-10-15 DOI: 10.3290/j.ijcd.b5786131
Florian Beuer
{"title":"Students and teachers.","authors":"Florian Beuer","doi":"10.3290/j.ijcd.b5786131","DOIUrl":"10.3290/j.ijcd.b5786131","url":null,"abstract":"","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"27 3","pages":"219-220"},"PeriodicalIF":1.8,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142478205","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A novel digital way to measure the vertical and horizontal dimensions of the supra-crestal peri-implant soft tissues. 测量牙冠上种植体周围软组织垂直和水平尺寸的新型数字化方法。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-07-29 DOI: 10.3290/j.ijcd.b5638066
Serge Szmukler-Moncler, Ariel Savion, Rasmus Sperber, Roni Kolerman, Florian Beuer

Aim: To report on a novel digital superimposition workflow that enables measuring the supra-crestal peri-implant soft tissue dimensions all along implant treatment and afterwards.

Materials and methods: A preoperative CBCT and intra-oral scans (IOS) are successively taken before surgery, at the end of the healing period, at prosthesis delivery, and over time; they are digitally superposed on a dedicated software. Then, the stereolithography files (STL) of the healing abutment, of the prosthetic abutment and the crown are successively merged into the superposition set of IOSs.

Result: The workflow protocol of merging successively the STL of each item into the superposition set of IOSs enables capturing the dimensions of the height and width of the supra-crestal soft tissues, at every level of the healing abutment, the prosthetic abutment and the crown. In addition, it allows measuring the vertical distance that the crown exerts pressure on the gingiva and the thickness of the papillae at every level of the abutment.

Conclusion: This novel digital superimposition workflow provides a straightforward method of measuring the vertical and horizontal dimensions of the supra-crestal peri-implant soft tissues, including the papillae, at each stage of the implant treatment process. It allows investigating a certain number of soft tissue variables that were previously inaccessible to clinical research. It should help enhancing our comprehension of the peri-implant soft tissue dynamics.

目的:报告一种新型的数字叠加工作流程,该流程能够在种植治疗过程中和之后测量种植体上牙冠周围软组织的尺寸:术前 CBCT 扫描和口内扫描(IOS)分别在术前、愈合期结束时、修复体交付时和一段时间后进行,并在专用软件上进行数字叠加。然后,将愈合基台、修复基台和牙冠的立体光刻文件(STL)陆续合并到 IOS 的叠加集中:结果:将每个项目的 STL 相继合并到 IOSs 叠加集的工作流程规程,可以捕捉到愈合基台、修复基台和牙冠每个层面的牙冠上软组织的高度和宽度尺寸。此外,还可以测量牙冠对牙龈施加压力的垂直距离以及基台各层乳头的厚度:这种新颖的数字叠加工作流程提供了一种直接的方法,可以在种植治疗过程的每个阶段测量包括乳头在内的种植体上牙冠周围软组织的垂直和水平尺寸。通过该方法可以对以前临床研究中无法获得的大量软组织变量进行研究。它将有助于提高我们对种植体周围软组织动态的理解。
{"title":"A novel digital way to measure the vertical and horizontal dimensions of the supra-crestal peri-implant soft tissues.","authors":"Serge Szmukler-Moncler, Ariel Savion, Rasmus Sperber, Roni Kolerman, Florian Beuer","doi":"10.3290/j.ijcd.b5638066","DOIUrl":"https://doi.org/10.3290/j.ijcd.b5638066","url":null,"abstract":"<p><strong>Aim: </strong>To report on a novel digital superimposition workflow that enables measuring the supra-crestal peri-implant soft tissue dimensions all along implant treatment and afterwards.</p><p><strong>Materials and methods: </strong>A preoperative CBCT and intra-oral scans (IOS) are successively taken before surgery, at the end of the healing period, at prosthesis delivery, and over time; they are digitally superposed on a dedicated software. Then, the stereolithography files (STL) of the healing abutment, of the prosthetic abutment and the crown are successively merged into the superposition set of IOSs.</p><p><strong>Result: </strong>The workflow protocol of merging successively the STL of each item into the superposition set of IOSs enables capturing the dimensions of the height and width of the supra-crestal soft tissues, at every level of the healing abutment, the prosthetic abutment and the crown. In addition, it allows measuring the vertical distance that the crown exerts pressure on the gingiva and the thickness of the papillae at every level of the abutment.</p><p><strong>Conclusion: </strong>This novel digital superimposition workflow provides a straightforward method of measuring the vertical and horizontal dimensions of the supra-crestal peri-implant soft tissues, including the papillae, at each stage of the implant treatment process. It allows investigating a certain number of soft tissue variables that were previously inaccessible to clinical research. It should help enhancing our comprehension of the peri-implant soft tissue dynamics.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141789558","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Patients' Perspective On The Inclusion Of Intraoral Scanners In Routine Examination: A Clinical Perception Study. 患者对将口腔内扫描仪纳入常规检查的看法:临床认知研究。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-07-29 DOI: 10.3290/j.ijcd.b5628817
İsmail Serhat Sadikoğlu, Melin Balci

Purpose: Is to investigate how integrating intraoral scanners in routine oral diagnosis affects patient-clinician communication, patient perceptions and preferences, offering valuable insights into the patient experience and utility of intraoral scanners in clinical practice.

Materials and methods: A restorative dentistry specialist conducted intraoral examination on 300 patients, initially using conventional techniques and X-rays, followed by a 3D scanner (ITero®element, Align Technologies, San Jose, California, USA). The patient's existing oral issues and treatment plan were initially expressed verbally, and then repeated using a 3D scan. Subsequently, the patients were requested to respond to an 11-question survey, aimed at assessing both modes of examination and communication. Statistical analysis using SPSS v.22 software included employing the Wilcoxon test to compare the patients' experiences on the same topic before and after the examination with the intraoral scanners, considering significance at p<0.05.

Results: Majority (38%) of participants aged 25-35. Gender split was 52% female, 48% male. Patients statistically found it more comprehensible to visualize existing oral issues through 3D scans than through verbal explanation (p=0.000). Also, patients understood oral hygiene recommendations better when explained via 3D scanning by dentists (p=,000). The vast majority of the participants (94%) indicated that being examined with an intraoral scanner motivated them for treatment, while 6% remained undecided. A hundred percent of the participants stated that 3D scanners should be included in the routine oral examination.

Conclusion: Intraoral 3D scans enhance patient understanding and communication during oral examination and participants show high preference. However, more research needed to replace conventional diagnostic methods.

目的:研究将口内扫描仪整合到常规口腔诊断中如何影响患者与医生的沟通、患者的看法和偏好,为临床实践中的患者体验和口内扫描仪的实用性提供有价值的见解:一名牙科修复专家对 300 名患者进行了口腔内检查,最初使用传统技术和 X 光,随后使用三维扫描仪(ITero®element,Align Technologies,美国加利福尼亚州圣何塞)。患者现有的口腔问题和治疗计划最初由口头表达,然后使用三维扫描重复表达。随后,患者被要求回答一份由 11 个问题组成的调查问卷,旨在评估检查和交流的两种模式。使用 SPSS v.22 软件进行的统计分析包括使用 Wilcoxon 检验比较患者在使用口内扫描仪进行检查前后对同一主题的体验,以 p 为显著性:大多数参与者(38%)的年龄在 25-35 岁之间。性别比例为女性 52%,男性 48%。据统计,患者认为通过三维扫描直观了解现有口腔问题比通过口头解释更容易理解(p=0.000)。此外,当牙医通过三维扫描进行解释时,患者能更好地理解口腔卫生建议(p=,000)。绝大多数参与者(94%)表示,口内扫描仪的检查促使他们接受治疗,而 6% 的参与者仍未做出决定。百分之百的参与者表示应将三维扫描仪纳入常规口腔检查:结论:口腔内 3D 扫描增强了口腔检查过程中患者的理解和交流,参与者对此表现出很高的偏好。然而,要取代传统的诊断方法,还需要更多的研究。
{"title":"Patients' Perspective On The Inclusion Of Intraoral Scanners In Routine Examination: A Clinical Perception Study.","authors":"İsmail Serhat Sadikoğlu, Melin Balci","doi":"10.3290/j.ijcd.b5628817","DOIUrl":"https://doi.org/10.3290/j.ijcd.b5628817","url":null,"abstract":"<p><strong>Purpose: </strong>Is to investigate how integrating intraoral scanners in routine oral diagnosis affects patient-clinician communication, patient perceptions and preferences, offering valuable insights into the patient experience and utility of intraoral scanners in clinical practice.</p><p><strong>Materials and methods: </strong>A restorative dentistry specialist conducted intraoral examination on 300 patients, initially using conventional techniques and X-rays, followed by a 3D scanner (ITero®element, Align Technologies, San Jose, California, USA). The patient's existing oral issues and treatment plan were initially expressed verbally, and then repeated using a 3D scan. Subsequently, the patients were requested to respond to an 11-question survey, aimed at assessing both modes of examination and communication. Statistical analysis using SPSS v.22 software included employing the Wilcoxon test to compare the patients' experiences on the same topic before and after the examination with the intraoral scanners, considering significance at p<0.05.</p><p><strong>Results: </strong>Majority (38%) of participants aged 25-35. Gender split was 52% female, 48% male. Patients statistically found it more comprehensible to visualize existing oral issues through 3D scans than through verbal explanation (p&#61;0.000). Also, patients understood oral hygiene recommendations better when explained via 3D scanning by dentists (p&#61;,000). The vast majority of the participants (94%) indicated that being examined with an intraoral scanner motivated them for treatment, while 6% remained undecided. A hundred percent of the participants stated that 3D scanners should be included in the routine oral examination.</p><p><strong>Conclusion: </strong>Intraoral 3D scans enhance patient understanding and communication during oral examination and participants show high preference. However, more research needed to replace conventional diagnostic methods.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141789489","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of the Application Value of Dynamic Navigation Guidance in Oral Implantation. 动态导航引导在口腔种植中的应用价值分析
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-07-18 DOI: 10.3290/j.ijcd.b5594243
Zhuo Wang

Objective: To investigate the application of dynamic navigation guidance technology in different implantation scenarios, and to provide a scientific basis for the innovation and advancement of implantation techniques.

Methods: Fifteen cases of patients with malocclusions admitted between January 2021 and February 2023 were selected as the study subjects. All patients underwent dynamic navigation-guided oral implantation interventions. CBCT scans were taken after implantation surgery to record deviations of implantation points, including implantation point deviation, endpoint deviation, and angle deviation.

Results: Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. CBCT effectively evaluated the state of the patient's periodontal implant, analyzed the state of the patient's lesion area, and improved the quality of implant intervention through CBCT guidance. The implantation point deviation was (0.407±0.193) mm, the endpoint deviation was (0.492±0.201) mm, and the implant angle deviation was (2.162±0.283)°. There was no significant difference in implantation point deviation in the anterior and posterior parts of the upper and lower jaws after intervention (P>0.05). However, there were significant differences in endpoint deviation and implant angle deviation among the anterior and posterior parts of the upper and lower jaws (P<0.05).

Conclusion: Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. However, there is relatively greater endpoint deviation and implant angle deviation in the posterior part of the upper jaw.

目的研究动态导航引导技术在不同种植情况下的应用,为种植技术的创新和进步提供科学依据:选取 2021 年 1 月至 2023 年 2 月期间收治的 15 例畸形牙患者作为研究对象。所有患者均接受了动态导航引导下的口腔种植干预。种植手术后进行CBCT扫描,记录种植点偏差,包括种植点偏差、端点偏差和角度偏差:结果:动态导航引导有效提高了口腔种植患者种植的可靠性和稳定性。CBCT有效评估了患者牙周种植体的状态,分析了患者病变区域的状态,通过CBCT引导提高了种植介入的质量。种植点偏差为(0.407±0.193)mm,端点偏差为(0.492±0.201)mm,种植角度偏差为(2.162±0.283)°。干预后,上下颌骨前部和后部的种植点偏差无明显差异(P>0.05)。但是,上下颌骨前部和后部的种植终点偏差和种植角度偏差有明显差异(P结论:动态导航引导能有效提高口腔种植患者种植体植入的可靠性和稳定性。然而,上颌后部的端点偏差和种植体角度偏差相对较大。
{"title":"Analysis of the Application Value of Dynamic Navigation Guidance in Oral Implantation.","authors":"Zhuo Wang","doi":"10.3290/j.ijcd.b5594243","DOIUrl":"10.3290/j.ijcd.b5594243","url":null,"abstract":"<p><strong>Objective: </strong>To investigate the application of dynamic navigation guidance technology in different implantation scenarios, and to provide a scientific basis for the innovation and advancement of implantation techniques.</p><p><strong>Methods: </strong>Fifteen cases of patients with malocclusions admitted between January 2021 and February 2023 were selected as the study subjects. All patients underwent dynamic navigation-guided oral implantation interventions. CBCT scans were taken after implantation surgery to record deviations of implantation points, including implantation point deviation, endpoint deviation, and angle deviation.</p><p><strong>Results: </strong>Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. CBCT effectively evaluated the state of the patient's periodontal implant, analyzed the state of the patient's lesion area, and improved the quality of implant intervention through CBCT guidance. The implantation point deviation was (0.407±0.193) mm, the endpoint deviation was (0.492±0.201) mm, and the implant angle deviation was (2.162±0.283)°. There was no significant difference in implantation point deviation in the anterior and posterior parts of the upper and lower jaws after intervention (P>0.05). However, there were significant differences in endpoint deviation and implant angle deviation among the anterior and posterior parts of the upper and lower jaws (P<0.05).</p><p><strong>Conclusion: </strong>Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. However, there is relatively greater endpoint deviation and implant angle deviation in the posterior part of the upper jaw.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141635058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
User experience of and satisfaction with computer-aided design software when designing dental prostheses: A multicenter survey study. 用户在设计义齿时对计算机辅助设计软件的体验和满意度:一项多中心调查研究。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-07-16 DOI: 10.3290/j.ijcd.b5582929
Thaw Thaw Win, Hang-Nga Mai, Shilpa Rana, Hyeong-Seob Kim, Ahran Pae, Seoung-Jin Hong, Younghoo Lee, Du-Hyeong Lee

Aim: The current study aimed to compare the responses and satisfaction reported by users with varying levels of experience when using different types of computer-aided design (CAD) software programs to design crowns.

Materials and methods: A questionnaire was used to evaluate user responses to five domains (software visibility, 3Dscanned data preparation, crown design and adjustment, finish line registration, and overall experience) of various CAD software programs. The study included 50 undergraduate dental students (inexperienced group) and 50 dentists or dental technicians from two hospitals (experienced group). The participants used four different CAD software programs (Meshmixer, Exocad, BlueSkyPlan, and Dentbird) to design crowns and recorded the features using the questionnaire. Statistical analyses included one-way and two-way analysis of variance (ANOVA) tests to compare scores and verify the interaction between user response and experience.

Result: User evaluation scores in the domains of software visibility and 3D-scanned data preparation varied between software programs (P < 0.001), with Exocad being favored by the experienced group. When evaluating crown design and finish line registration, Dentbird and Exocad scored significantly higher than the other software in both groups as they offered automation of the process using deep learning (P < 0.001). Two-way ANOVA showed that prior experience of using CAD significantly affected the users' responses to all queries (P < 0.001).

Conclusion: User response and satisfaction varied with the type of CAD software used to design dental prostheses, with prior experience of using CAD playing a significant role. Automation of design functions can enhance user satisfaction with the software.

目的:本研究旨在比较不同经验水平的用户在使用不同类型的计算机辅助设计(CAD)软件程序设计牙冠时的反应和满意度:使用调查问卷评估用户对各种 CAD 软件五个方面(软件可视性、三维扫描数据准备、牙冠设计和调整、终点线注册和总体体验)的反应。研究对象包括 50 名牙科本科生(无经验组)和来自两家医院的 50 名牙医或牙科技师(有经验组)。参与者使用四种不同的 CAD 软件(Meshmixer、Exocad、BlueSkyPlan 和 Dentbird)设计牙冠,并使用问卷记录特征。统计分析包括单因子和双因子方差分析(ANOVA)测试,以比较得分并验证用户反应与经验之间的交互作用:结果:不同软件程序在软件可视性和三维扫描数据准备方面的用户评价得分存在差异(P < 0.001),经验丰富的用户组更青睐 Exocad。在评估牙冠设计和终点线注册时,Dentbird 和 Exocad 的得分明显高于两组中的其他软件,因为它们利用深度学习实现了流程自动化(P < 0.001)。双向方差分析显示,使用 CAD 的先前经验会显著影响用户对所有问题的回答(P < 0.001):用户的反应和满意度随设计牙科修复体所使用的 CAD 软件类型的不同而变化,其中使用 CAD 的先前经验起着重要作用。设计功能的自动化可以提高用户对软件的满意度。
{"title":"User experience of and satisfaction with computer-aided design software when designing dental prostheses: A multicenter survey study.","authors":"Thaw Thaw Win, Hang-Nga Mai, Shilpa Rana, Hyeong-Seob Kim, Ahran Pae, Seoung-Jin Hong, Younghoo Lee, Du-Hyeong Lee","doi":"10.3290/j.ijcd.b5582929","DOIUrl":"10.3290/j.ijcd.b5582929","url":null,"abstract":"<p><strong>Aim: </strong>The current study aimed to compare the responses and satisfaction reported by users with varying levels of experience when using different types of computer-aided design (CAD) software programs to design crowns.</p><p><strong>Materials and methods: </strong>A questionnaire was used to evaluate user responses to five domains (software visibility, 3Dscanned data preparation, crown design and adjustment, finish line registration, and overall experience) of various CAD software programs. The study included 50 undergraduate dental students (inexperienced group) and 50 dentists or dental technicians from two hospitals (experienced group). The participants used four different CAD software programs (Meshmixer, Exocad, BlueSkyPlan, and Dentbird) to design crowns and recorded the features using the questionnaire. Statistical analyses included one-way and two-way analysis of variance (ANOVA) tests to compare scores and verify the interaction between user response and experience.</p><p><strong>Result: </strong>User evaluation scores in the domains of software visibility and 3D-scanned data preparation varied between software programs (P < 0.001), with Exocad being favored by the experienced group. When evaluating crown design and finish line registration, Dentbird and Exocad scored significantly higher than the other software in both groups as they offered automation of the process using deep learning (P < 0.001). Two-way ANOVA showed that prior experience of using CAD significantly affected the users' responses to all queries (P < 0.001).</p><p><strong>Conclusion: </strong>User response and satisfaction varied with the type of CAD software used to design dental prostheses, with prior experience of using CAD playing a significant role. Automation of design functions can enhance user satisfaction with the software.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141621209","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Volumetric differences in the temporomandibular joint in patients with condylar hyperplasia in active and passive state, SPECT/CT study. 髁状突增生患者在主动和被动状态下颞下颌关节的体积差异,SPECT/CT 研究。
IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-07-16 DOI: 10.3290/j.ijcd.b5582925
Diego Fernando López

Aim: Condylar hyperplasia (CH) is a progressive and deforming disease that modifies anatomy of the temporomandibular joint (TMJ) structures. This study aims to correlate the metabolic bone activity of the condyle measured by SPECT with the volumetry anatomic information from the condyle, fossa and joint space provided by CT images, in patients with CH in active and inactive forms.

Materials and methods: A cross-sectional comparative study was performed with a set of 116 images from healthy and diagnosed CH patients to compare volumetric measures of the TMJ. Images were acquired through a bone tissue mask using a three-dimensional DICOM reconstruction for SPECT/CT and CBCT images and the Threshold option for segmentation with standardized values for each tissue on the HU scale.

Results: there are differences (p<0.01), with greater condylar volume on the affected side in patients with active CH compared to passive CH. The volume of the glenoid cavity shows no differences in either form of CH (p>0.05), however, there were differences for the volume of the joint space on the affected right side of hemimandibular elongation (HE) in the active form. The volume of the mandibular condyle on the affected side in CH cases were larger in HE cases in active and inactive form (p<0.01) compared to healthy patients. Similar results were presented for the glenoid cavity and joint space.

Conclusions: Volumetric anatomical evaluation of TMJ structures, as well as information on condylar metabolic activity, can be obtained from SPECT/CT. The study shows a greater condylar volume on the affected side of the CH compared to the contralateral side, but there are more significant differences in the active than in the inactive form.

目的:髁突增生症(CH)是一种进展性畸形疾病,会改变颞下颌关节(TMJ)结构的解剖学。本研究旨在将 SPECT 测量的髁状突代谢骨活性与 CT 图像提供的髁状突、窝和关节间隙的容积解剖信息联系起来:对一组 116 张健康和确诊 CH 患者的图像进行了横断面比较研究,以比较颞下颌关节的容积测量。使用三维 DICOM 重建 SPECT/CT 和 CBCT 图像,通过骨组织掩膜获取图像,并使用阈值选项进行分割,每个组织在 HU 标度上都有标准化值。CH病例患侧下颌骨髁状突的体积在活动型和非活动型HE病例中均较大(P结论:通过 SPECT/CT 可以获得颞下颌关节结构的体积解剖学评估以及髁突代谢活动的信息。研究显示,与对侧相比,CH 患侧的髁突体积更大,但活动型的差异比非活动型更明显。
{"title":"Volumetric differences in the temporomandibular joint in patients with condylar hyperplasia in active and passive state, SPECT/CT study.","authors":"Diego Fernando López","doi":"10.3290/j.ijcd.b5582925","DOIUrl":"10.3290/j.ijcd.b5582925","url":null,"abstract":"<p><strong>Aim: </strong>Condylar hyperplasia (CH) is a progressive and deforming disease that modifies anatomy of the temporomandibular joint (TMJ) structures. This study aims to correlate the metabolic bone activity of the condyle measured by SPECT with the volumetry anatomic information from the condyle, fossa and joint space provided by CT images, in patients with CH in active and inactive forms.</p><p><strong>Materials and methods: </strong>A cross-sectional comparative study was performed with a set of 116 images from healthy and diagnosed CH patients to compare volumetric measures of the TMJ. Images were acquired through a bone tissue mask using a three-dimensional DICOM reconstruction for SPECT/CT and CBCT images and the Threshold option for segmentation with standardized values for each tissue on the HU scale.</p><p><strong>Results: </strong>there are differences (p<0.01), with greater condylar volume on the affected side in patients with active CH compared to passive CH. The volume of the glenoid cavity shows no differences in either form of CH (p>0.05), however, there were differences for the volume of the joint space on the affected right side of hemimandibular elongation (HE) in the active form. The volume of the mandibular condyle on the affected side in CH cases were larger in HE cases in active and inactive form (p<0.01) compared to healthy patients. Similar results were presented for the glenoid cavity and joint space.</p><p><strong>Conclusions: </strong>Volumetric anatomical evaluation of TMJ structures, as well as information on condylar metabolic activity, can be obtained from SPECT/CT. The study shows a greater condylar volume on the affected side of the CH compared to the contralateral side, but there are more significant differences in the active than in the inactive form.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141621210","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
International Journal of Computerized Dentistry
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1