首页 > 最新文献

Prosthesis最新文献

英文 中文
Analysis of Early-Retrieved Dual-Mobility Polyethylene Liners for Total Hip Replacement 用于全髋关节置换术的早期回收双活动聚乙烯衬垫分析
Pub Date : 2024-07-25 DOI: 10.3390/prosthesis6040060
Mackenzie Smeeton, G. Isaac, Ruth Wilcox, James Anderson, T. Board, D. V. Van Citters, Sophie Williams
Despite their emerging use, the in vivo behaviour of dual-mobility (DM) total hip replacements (THRs) is not well understood. Therefore, the purpose of this study was to assess the articulating surfaces of 20 early-retrieved DM polyethylene liners (mean length of implantation 20.0 ± 18.8 months) for damage to improve the current understanding of their in vivo functional mechanisms. The internal and external surfaces of each liner were visually and geometrically assessed, and the material composition of embedded debris particles were further characterized. Scratching and pitting were the most common modes of damage identified on either surface, and a high incidence of burnishing (50%) and embedded debris (65%) were observed on the internal and external surfaces, respectively. Embedded debris particles were commonly titanium- or iron-based, although other materials such as cobalt-chrome and tantalum were also identified. The geometric assessment demonstrated highly variable damage patterns across the liners, with the internal surfaces commonly presenting with crescent-shaped, circumferential, or circular regions of penetration whilst the external surfaces commonly presented with regions of deep pitting or gouging. This study demonstrates that DM-THRs primarily articulate at the head/liner junction, and that polyethylene liners are capable of rotating about the femoral neck axis, although the extent of this may be limited in some cases. Additionally, this study suggests that intra-prosthetic dislocation and edge loading may remain pertinent failure mechanisms of DM implants despite the advent of highly crosslinked polyethylene and design features, thus highlighting the need for enhanced monitoring of these devices.
尽管双活动度(DM)全髋关节置换术(THR)的使用正在兴起,但人们对其体内行为还不甚了解。因此,本研究的目的是评估 20 个早期取出的 DM 聚乙烯衬垫(平均植入时间为 20.0 ± 18.8 个月)的关节表面是否有损坏,以加深目前对其体内功能机制的了解。我们对每个衬垫的内外表面进行了目测和几何评估,并进一步确定了嵌入碎屑颗粒的材料成分。划痕和点蚀是两种表面上最常见的损伤模式,在内外表面分别观察到了较高的烧蚀(50%)和嵌入碎片(65%)发生率。嵌入的碎片颗粒通常为钛或铁基,但也发现了钴铬和钽等其他材料。几何评估显示,内衬的损坏模式差异很大,内表面通常会出现新月形、圆周形或圆形的穿透区域,而外表面则通常会出现深点蚀或挖蚀区域。本研究表明,DM-THR 主要在头部/内衬交界处发生铰接,聚乙烯内衬能够围绕股骨颈轴线旋转,但在某些情况下旋转范围可能有限。此外,本研究还表明,尽管出现了高交联聚乙烯和设计特点,但假体内脱位和边缘加载仍可能是DM假体的相关失效机制,因此需要加强对这些假体的监测。
{"title":"Analysis of Early-Retrieved Dual-Mobility Polyethylene Liners for Total Hip Replacement","authors":"Mackenzie Smeeton, G. Isaac, Ruth Wilcox, James Anderson, T. Board, D. V. Van Citters, Sophie Williams","doi":"10.3390/prosthesis6040060","DOIUrl":"https://doi.org/10.3390/prosthesis6040060","url":null,"abstract":"Despite their emerging use, the in vivo behaviour of dual-mobility (DM) total hip replacements (THRs) is not well understood. Therefore, the purpose of this study was to assess the articulating surfaces of 20 early-retrieved DM polyethylene liners (mean length of implantation 20.0 ± 18.8 months) for damage to improve the current understanding of their in vivo functional mechanisms. The internal and external surfaces of each liner were visually and geometrically assessed, and the material composition of embedded debris particles were further characterized. Scratching and pitting were the most common modes of damage identified on either surface, and a high incidence of burnishing (50%) and embedded debris (65%) were observed on the internal and external surfaces, respectively. Embedded debris particles were commonly titanium- or iron-based, although other materials such as cobalt-chrome and tantalum were also identified. The geometric assessment demonstrated highly variable damage patterns across the liners, with the internal surfaces commonly presenting with crescent-shaped, circumferential, or circular regions of penetration whilst the external surfaces commonly presented with regions of deep pitting or gouging. This study demonstrates that DM-THRs primarily articulate at the head/liner junction, and that polyethylene liners are capable of rotating about the femoral neck axis, although the extent of this may be limited in some cases. Additionally, this study suggests that intra-prosthetic dislocation and edge loading may remain pertinent failure mechanisms of DM implants despite the advent of highly crosslinked polyethylene and design features, thus highlighting the need for enhanced monitoring of these devices.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"29 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141806142","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Long-Term Results of Third Generation of Rotating Hinge Arthroplasty in Patients with Poliomyelitis 第三代旋转铰链关节置换术在脊髓灰质炎患者中的长期效果
Pub Date : 2024-07-25 DOI: 10.3390/prosthesis6040061
D. Tigani, Enrico Ferranti Calderoni, M. Berti, S. Comitini, L. Amendola, G. Pipino, Giuseppe Melucci
Background: Total knee arthroplasty (TKA) for poliomyelitis patients is controversial due to its higher complication rate compared with that of TKA for osteoarthritis. In this study we evaluated the results, at a minimum of 10 years, of a consecutive series of third-generation rotating hinge total knee arthroplasties (RHKs) in patients affected by poliomyelitis. Methods: We conducted a retrospective analysis of 14 patients (15 TKA) performed between January 2000 and October 2021 that underwent a third-generation rotating hinge arthroplasty (Nex Gen RHK Zimmer). The clinical results using the American Knee Society Score (AKSS) were evaluated at an average follow-up of 154 months (min 120–max 216 months). Result: Of the 15 cases, 2 were lost at follow-up and 1 was excluded by the final evaluation due to infection. Of the remaining 12 cases at the final follow-up, the average AKKS clinical score improved from 30.08 points preoperatively, to 78.83 points postoperatively, while the average AKKS function score improved from 29.17 points to 56.25 points. We report only one intraoperative complication consisting of a femoral fracture at the tip of the stem, and a case of patellar fracture occurred 3 months after the index procedure. The presence of radiolucent lines was sporadic, while radiosclerotic lines were commonly visible around the stem extension, predominantly at the tip. Conclusions: The third generation of rotating hinge knee replacement has proved to be effective in polio patients, improving clinical and functional scores, and no cases of mechanical failure occurred.
背景:脊髓灰质炎患者的全膝关节置换术(TKA)因其并发症发生率高于骨关节炎患者而备受争议。在这项研究中,我们对脊髓灰质炎患者连续接受第三代旋转铰链全膝关节置换术(RHK)至少 10 年的结果进行了评估。方法:我们对 2000 年 1 月至 2021 年 10 月间接受第三代旋转铰链关节置换术(Nex Gen RHK Zimmer)的 14 例患者(15 例 TKA)进行了回顾性分析。平均随访 154 个月(最短 120 个月,最长 216 个月),使用美国膝关节协会评分(AKSS)评估临床结果。结果:在 15 例随访病例中,2 例因感染而失去随访机会,1 例因感染而在最终评估中被排除。在最终随访的其余 12 例患者中,AKKS 临床平均得分从术前的 30.08 分提高到术后的 78.83 分,AKKS 功能平均得分从 29.17 分提高到 56.25 分。我们仅报告了一例术中并发症,即股骨柄顶端骨折,以及一例指数手术后3个月发生的髌骨骨折。放射线的存在是零星的,而放射硬化线则常见于骨干延伸的周围,主要是在顶端。结论:事实证明,第三代旋转铰链膝关节置换术对小儿麻痹症患者有效,可改善临床和功能评分,且未出现机械故障。
{"title":"Long-Term Results of Third Generation of Rotating Hinge Arthroplasty in Patients with Poliomyelitis","authors":"D. Tigani, Enrico Ferranti Calderoni, M. Berti, S. Comitini, L. Amendola, G. Pipino, Giuseppe Melucci","doi":"10.3390/prosthesis6040061","DOIUrl":"https://doi.org/10.3390/prosthesis6040061","url":null,"abstract":"Background: Total knee arthroplasty (TKA) for poliomyelitis patients is controversial due to its higher complication rate compared with that of TKA for osteoarthritis. In this study we evaluated the results, at a minimum of 10 years, of a consecutive series of third-generation rotating hinge total knee arthroplasties (RHKs) in patients affected by poliomyelitis. Methods: We conducted a retrospective analysis of 14 patients (15 TKA) performed between January 2000 and October 2021 that underwent a third-generation rotating hinge arthroplasty (Nex Gen RHK Zimmer). The clinical results using the American Knee Society Score (AKSS) were evaluated at an average follow-up of 154 months (min 120–max 216 months). Result: Of the 15 cases, 2 were lost at follow-up and 1 was excluded by the final evaluation due to infection. Of the remaining 12 cases at the final follow-up, the average AKKS clinical score improved from 30.08 points preoperatively, to 78.83 points postoperatively, while the average AKKS function score improved from 29.17 points to 56.25 points. We report only one intraoperative complication consisting of a femoral fracture at the tip of the stem, and a case of patellar fracture occurred 3 months after the index procedure. The presence of radiolucent lines was sporadic, while radiosclerotic lines were commonly visible around the stem extension, predominantly at the tip. Conclusions: The third generation of rotating hinge knee replacement has proved to be effective in polio patients, improving clinical and functional scores, and no cases of mechanical failure occurred.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"16 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141803553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical Effects of Interproximal Contact Loss between Teeth and Implant-Supported Prostheses: Systematic Review and Meta-Analysis 牙齿与种植体支撑假体之间近端接触丧失的临床影响:系统回顾和元分析
Pub Date : 2024-07-18 DOI: 10.3390/prosthesis6040059
James Carlos Nery, Patrícia Manarte-Monteiro, Leonardo Aragão, Lígia Pereira da Silva, Gabriel Silveira Pinto Brandão, B. F. Lemos
Dental rehabilitation with implants is a clinical reality in clinical practice. The Interproximal Contact Loss (ICL) between implant-supported prostheses adjacent to natural teeth is a relatively common occurrence. This systematic review and meta-analysis aims to evaluate the possible clinical effects of the periodontium regarding the ICL between teeth and implanted-supported prostheses. We also identified the main ICL assessment tools described in the literature. This study was registered on the PROSPERO (CRD42023446235), was based on the PICO strategy, and followed the PRISMA guidelines. An electronic search was carried out in the PubMed, B-on, Google Scholar, and Web of Science databases without setting a time limit for publications. Only systematic reviews and comparative clinical trials were included and analyzed. Nineteen publications were eligible for meta-analysis, with thirteen retrospective and six prospective clinical trials. A total of 2047 patients and 7319 prostheses in function were evaluated, and ICL was found in 51% with a confidence interval of 0.40 to 0.61. As ICL assessment tools, dental floss was used in 65%, matrices were used in 30%, and X-ray images were used in 5% of cases. The clinical follow-up ranged from 1 to 21 years, with 50% between 1 and 3 years, 25% between 3 and 10 years, and 25% between 10 and 21 years. ICL was found to occur more frequently in the mandible. No statistically significant difference existed between the anterior (55%) and posterior (47%) oral regions. On the mesial surface, ICL ranged from 13% to 81.4%, possibly due to the different follow-up periods and the diversity of methods used in the assessment. No differences were found for ICL between single or multiple implanted-supported prostheses. Food impaction was the most common effect of ICL and was more prevalent on the implant-supported prosthesis’s mesial surface in the mandible’s posterior region. There was evidence of peri-implant mucositis but without progression to peri-implantitis, and the form of retention or the number of elements was not relevant.
使用种植体进行牙科康复是临床实践中的现实问题。与天然牙相邻的种植体支持修复体之间的近端接触丧失(ICL)是一种比较常见的现象。本系统综述和荟萃分析旨在评估牙周对牙齿和种植义齿间接触损失可能产生的临床影响。我们还确定了文献中描述的主要 ICL 评估工具。本研究在 PROSPERO(CRD42023446235)上注册,基于 PICO 策略,并遵循 PRISMA 指南。在 PubMed、B-on、Google Scholar 和 Web of Science 数据库中进行了电子检索,未设定发表时间限制。只纳入并分析了系统综述和比较临床试验。符合荟萃分析条件的出版物有 19 篇,其中 13 篇为回顾性临床试验,6 篇为前瞻性临床试验。共对 2047 名患者和 7319 个修复体的功能进行了评估,发现 51% 的患者有 ICL,置信区间为 0.40 至 0.61。作为 ICL 的评估工具,65% 的病例使用牙线,30% 的病例使用矩阵,5% 的病例使用 X 光图像。临床随访时间从1年到21年不等,其中50%在1年到3年之间,25%在3年到10年之间,25%在10年到21年之间。研究发现,ICL更多发生在下颌骨。口腔前部(55%)和口腔后部(47%)之间没有明显的统计学差异。在中面,ICL的发生率从13%到81.4%不等,这可能是由于随访时间不同和评估方法的多样性造成的。单颗或多颗种植义齿之间的 ICL 没有差异。食物嵌塞是 ICL 最常见的影响,在下颌后部种植体支持修复体的中轴表面更为常见。有证据表明存在种植体周围粘膜炎,但没有发展为种植体周围炎,而且固位形式或固位体数量与此无关。
{"title":"Clinical Effects of Interproximal Contact Loss between Teeth and Implant-Supported Prostheses: Systematic Review and Meta-Analysis","authors":"James Carlos Nery, Patrícia Manarte-Monteiro, Leonardo Aragão, Lígia Pereira da Silva, Gabriel Silveira Pinto Brandão, B. F. Lemos","doi":"10.3390/prosthesis6040059","DOIUrl":"https://doi.org/10.3390/prosthesis6040059","url":null,"abstract":"Dental rehabilitation with implants is a clinical reality in clinical practice. The Interproximal Contact Loss (ICL) between implant-supported prostheses adjacent to natural teeth is a relatively common occurrence. This systematic review and meta-analysis aims to evaluate the possible clinical effects of the periodontium regarding the ICL between teeth and implanted-supported prostheses. We also identified the main ICL assessment tools described in the literature. This study was registered on the PROSPERO (CRD42023446235), was based on the PICO strategy, and followed the PRISMA guidelines. An electronic search was carried out in the PubMed, B-on, Google Scholar, and Web of Science databases without setting a time limit for publications. Only systematic reviews and comparative clinical trials were included and analyzed. Nineteen publications were eligible for meta-analysis, with thirteen retrospective and six prospective clinical trials. A total of 2047 patients and 7319 prostheses in function were evaluated, and ICL was found in 51% with a confidence interval of 0.40 to 0.61. As ICL assessment tools, dental floss was used in 65%, matrices were used in 30%, and X-ray images were used in 5% of cases. The clinical follow-up ranged from 1 to 21 years, with 50% between 1 and 3 years, 25% between 3 and 10 years, and 25% between 10 and 21 years. ICL was found to occur more frequently in the mandible. No statistically significant difference existed between the anterior (55%) and posterior (47%) oral regions. On the mesial surface, ICL ranged from 13% to 81.4%, possibly due to the different follow-up periods and the diversity of methods used in the assessment. No differences were found for ICL between single or multiple implanted-supported prostheses. Food impaction was the most common effect of ICL and was more prevalent on the implant-supported prosthesis’s mesial surface in the mandible’s posterior region. There was evidence of peri-implant mucositis but without progression to peri-implantitis, and the form of retention or the number of elements was not relevant.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141824346","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mortality Rate in Periprosthetic Proximal Femoral Fractures: Impact of Time to Surgery 股骨近端假体周围骨折的死亡率:手术时间的影响
Pub Date : 2024-07-17 DOI: 10.3390/prosthesis6040058
Jacopo Vittori, Norsaga Hoxha, F. Dettoni, Carolina Rivoira, Roberto Rossi, Umberto Cottino
Hip replacement surgery is increasingly being performed on older patients, raising the risk of periprosthetic proximal femur fractures (PPFFs). While the impact of surgery timing on mortality in proximal femoral fractures is established, its effect on PPFFs remains unclear. This study aims to examine the correlation between surgery timing and mortality in PPFF patients. In a historical cohort study, we analyzed data from 79 PPFF patients treated from 2012 to 2022. Patients were categorized by surgery timing (≤48 h, 32 patients vs. >48 h, 47 patients). Outcomes and mortality rates were compared. No significant difference in mortality was observed between patients undergoing early (<48 h) and delayed (>48 h) surgery at 30 days and 1 year. Factors such as age (p = 0.154), gender (p = 0.058), ASA score (p = 0.893), Vancouver classification (p = 0.577), and surgery type (implant revision p = 0.691, OR = 0.667) did not affect 30-day mortality. However, 1-year mortality was influenced by gender (male p = 0.045) and age (p = 0.004), but not by other variables (Vancouver classification p = 0.443, implant revision p = 0.196). These findings indicate no association between surgery timing and mortality in PPFF patients, suggesting that other factors may influence outcomes. Further research is needed to optimize PPFF management.
越来越多的老年患者接受髋关节置换手术,从而增加了股骨近端假体周围骨折(PPFF)的风险。虽然手术时机对股骨近端骨折死亡率的影响已经确定,但其对 PPFF 的影响仍不明确。本研究旨在探讨手术时机与 PPFF 患者死亡率之间的相关性。在一项历史队列研究中,我们分析了从2012年到2022年接受治疗的79名PPFF患者的数据。患者按手术时间分类(≤48小时,32例;>48小时,47例)。对结果和死亡率进行了比较。早期(48小时)手术患者在30天和1年后的死亡率无明显差异。年龄(p = 0.154)、性别(p = 0.058)、ASA 评分(p = 0.893)、温哥华分级(p = 0.577)和手术类型(植入物翻修 p = 0.691,OR = 0.667)等因素对 30 天死亡率没有影响。然而,1 年死亡率受性别(男性 p = 0.045)和年龄(p = 0.004)的影响,但不受其他变量(温哥华分类 p = 0.443,植入物翻修 p = 0.196)的影响。这些研究结果表明,PPFF 患者的手术时机与死亡率之间没有关联,这表明其他因素可能会影响手术效果。要优化 PPFF 的管理,还需要进一步的研究。
{"title":"Mortality Rate in Periprosthetic Proximal Femoral Fractures: Impact of Time to Surgery","authors":"Jacopo Vittori, Norsaga Hoxha, F. Dettoni, Carolina Rivoira, Roberto Rossi, Umberto Cottino","doi":"10.3390/prosthesis6040058","DOIUrl":"https://doi.org/10.3390/prosthesis6040058","url":null,"abstract":"Hip replacement surgery is increasingly being performed on older patients, raising the risk of periprosthetic proximal femur fractures (PPFFs). While the impact of surgery timing on mortality in proximal femoral fractures is established, its effect on PPFFs remains unclear. This study aims to examine the correlation between surgery timing and mortality in PPFF patients. In a historical cohort study, we analyzed data from 79 PPFF patients treated from 2012 to 2022. Patients were categorized by surgery timing (≤48 h, 32 patients vs. >48 h, 47 patients). Outcomes and mortality rates were compared. No significant difference in mortality was observed between patients undergoing early (<48 h) and delayed (>48 h) surgery at 30 days and 1 year. Factors such as age (p = 0.154), gender (p = 0.058), ASA score (p = 0.893), Vancouver classification (p = 0.577), and surgery type (implant revision p = 0.691, OR = 0.667) did not affect 30-day mortality. However, 1-year mortality was influenced by gender (male p = 0.045) and age (p = 0.004), but not by other variables (Vancouver classification p = 0.443, implant revision p = 0.196). These findings indicate no association between surgery timing and mortality in PPFF patients, suggesting that other factors may influence outcomes. Further research is needed to optimize PPFF management.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141831504","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Implant-Prosthetic Rehabilitation of the Agenesis of Maxillary Lateral Incisors: A 2-Year Prospective Clinical Study with Full Digital Workflow 上颌侧切牙缺失的种植修复治疗:采用全数字化工作流程的两年期前瞻性临床研究
Pub Date : 2024-07-16 DOI: 10.3390/prosthesis6040057
R. Sorrentino, M. I. Di Mauro, G. Ruggiero, R. Leone, E. Ferrari Cagidiaco, Marco Annunziata, Marco Ferrari, F. Zarone
The main objectives of the present prospective clinical study were to evaluate the survival and success rates of implant-supported zirconia single crowns fabricated with a full digital workflow for the rehabilitation of mono- and bilateral agenesis of maxillary lateral incisors after 2 years of clinical function; biological and technical parameters affecting the prosthetic restorations were recorded, as well as the patient-satisfaction score. Twenty-two patients showing mono- or bilateral agenesis of the maxillary lateral incisors were included in this study, and a total of 30 narrow-diameter implants were inserted. Thirty screw-retained monolithic cubic zirconia single crowns with internal connections were fabricated. Objective outcome evaluations were performed by means of the Functional Implant Prosthodontic Score, whereas the patient-satisfaction score was evaluated using Visual Analog Scales. Descriptive statistics were performed and the Kaplan–Meier analysis was run to analyze time-to-event data. After 2 years of clinical function, the overall FIPS found in the present study was 9.2, whereas the average patient-satisfaction score was 8.7. The Kaplan–Meier analysis at the 2-year follow-up reported a cumulative survival rate of 100% and a cumulative success rate of 93.3%. The implant-prosthetic rehabilitation with a full digital workflow proved to be an effective and reliable procedure for the functional and aesthetic treatment of the agenesis of maxillary lateral incisors in the short-term. Clinical investigations with wider sample populations and longer observational follow-ups could be useful to validate, in the long-term, the clinical outcomes of the present prospective clinical study.
本前瞻性临床研究的主要目的是评估采用全数字化工作流程制作的种植体支撑氧化锆单冠修复单侧和双侧上颌侧切牙缺失两年后的存活率和成功率;记录影响修复体的生物和技术参数以及患者满意度评分。本研究共纳入了22名上颌侧切牙单侧或双侧缺失的患者,共植入了30颗窄直径种植体。制作了 30 个带内连接的螺钉固位整体立方氧化锆单冠。客观结果评估采用种植修复功能评分法,患者满意度评分采用视觉模拟评分法。研究人员进行了描述性统计,并采用 Kaplan-Meier 分析法对事件发生时间的数据进行了分析。经过两年的临床功能锻炼后,本研究中发现的总体 FIPS 为 9.2,而患者满意度平均分为 8.7。两年随访的 Kaplan-Meier 分析显示,累计存活率为 100%,累计成功率为 93.3%。事实证明,在短期内,采用全数字化工作流程进行种植修复是一种有效、可靠的上颌侧切牙缺失的功能性和美学治疗方法。更广泛的样本人群和更长时间的随访观察将有助于长期验证本前瞻性临床研究的临床结果。
{"title":"Implant-Prosthetic Rehabilitation of the Agenesis of Maxillary Lateral Incisors: A 2-Year Prospective Clinical Study with Full Digital Workflow","authors":"R. Sorrentino, M. I. Di Mauro, G. Ruggiero, R. Leone, E. Ferrari Cagidiaco, Marco Annunziata, Marco Ferrari, F. Zarone","doi":"10.3390/prosthesis6040057","DOIUrl":"https://doi.org/10.3390/prosthesis6040057","url":null,"abstract":"The main objectives of the present prospective clinical study were to evaluate the survival and success rates of implant-supported zirconia single crowns fabricated with a full digital workflow for the rehabilitation of mono- and bilateral agenesis of maxillary lateral incisors after 2 years of clinical function; biological and technical parameters affecting the prosthetic restorations were recorded, as well as the patient-satisfaction score. Twenty-two patients showing mono- or bilateral agenesis of the maxillary lateral incisors were included in this study, and a total of 30 narrow-diameter implants were inserted. Thirty screw-retained monolithic cubic zirconia single crowns with internal connections were fabricated. Objective outcome evaluations were performed by means of the Functional Implant Prosthodontic Score, whereas the patient-satisfaction score was evaluated using Visual Analog Scales. Descriptive statistics were performed and the Kaplan–Meier analysis was run to analyze time-to-event data. After 2 years of clinical function, the overall FIPS found in the present study was 9.2, whereas the average patient-satisfaction score was 8.7. The Kaplan–Meier analysis at the 2-year follow-up reported a cumulative survival rate of 100% and a cumulative success rate of 93.3%. The implant-prosthetic rehabilitation with a full digital workflow proved to be an effective and reliable procedure for the functional and aesthetic treatment of the agenesis of maxillary lateral incisors in the short-term. Clinical investigations with wider sample populations and longer observational follow-ups could be useful to validate, in the long-term, the clinical outcomes of the present prospective clinical study.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141831547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Freehand Technique: The Ability of the Human Eye to Identify Implant Sites on the Patient 徒手技术:人眼识别患者植入位置的能力
Pub Date : 2024-05-21 DOI: 10.3390/prosthesis6030039
E. Cumbo, Giuseppe Gallina, P. Messina, Luigi Caradonna, G. Scardina
In implantology, among the key choices, to obtain predictable results, it is essential to establish, using cone beam computed tomography (CBCT), the bone site and where to insert the implants; during the surgical phase, these sites must be identified on the oral mucosa. Surgical templates are a valid aid, especially in complex cases which require the insertion of more than three or four implants. In cases of a single implant, on the other hand, surgical guides are rarely used, and the implant is often inserted freehand; therefore, the identification of the implant site on the oral mucosa (after choosing the location on the CBCT) is more difficult. For this reason, the clinician uses the teeth in the arch as a reference. This study evaluates the ability of the human eye to identify, on the oral mucosa, where the implant collars will be positioned, the position of which has previously been chosen on the CBCT, in cases where the hands-free surgical technique (without surgical guides) is used. The verification of this precision is carried out using particular thermo-printed templates which contain radiopaque metal spheres. The results show that, in the freehand technique, it is difficult to precisely identify the implant sites (chosen via X-ray) on the mucosa, especially when they are far from natural teeth adjacent to the edentulous area. In case of monoedentulism, the freehand implant technique seems to be applicable by expert implantologists with a reduced risk of error; in fact, clinical experience helps to find the correct correspondence between the implant site chosen on the CBCT and its identification on the mucosa. The level of experience is fundamental in the clinician’s decision about whether or not to use surgical guides; in fact, doctors with little experience should use surgical guides even in the simplest cases to reduce the risk of error.
在种植学的关键选择中,为了获得可预测的效果,必须使用锥形束计算机断层扫描(CBCT)确定骨部位和植入种植体的位置;在手术阶段,必须在口腔粘膜上确定这些部位。手术模板是一种有效的辅助工具,尤其是在需要植入三到四个以上种植体的复杂病例中。另一方面,在单颗种植体的病例中,很少使用手术导板,通常都是徒手植入种植体;因此,在口腔粘膜上识别种植体位置(在 CBCT 上选择位置后)更加困难。因此,临床医生使用牙弓中的牙齿作为参考。本研究评估了在使用免提手术技术(不使用手术导板)的情况下,人眼在口腔黏膜上识别种植体基台位置的能力。使用含有不透射线金属球的特殊热打印模板,可以验证这种精确性。结果表明,在徒手技术中,很难在粘膜上精确识别种植体位置(通过 X 射线选择),尤其是当种植体位置远离邻近缺牙区的天然牙齿时。事实上,临床经验有助于找到 CBCT 上选择的种植部位与粘膜上识别的正确对应关系。经验水平是临床医生决定是否使用手术导板的基础;事实上,经验不足的医生即使在最简单的病例中也应使用手术导板,以降低出错的风险。
{"title":"The Freehand Technique: The Ability of the Human Eye to Identify Implant Sites on the Patient","authors":"E. Cumbo, Giuseppe Gallina, P. Messina, Luigi Caradonna, G. Scardina","doi":"10.3390/prosthesis6030039","DOIUrl":"https://doi.org/10.3390/prosthesis6030039","url":null,"abstract":"In implantology, among the key choices, to obtain predictable results, it is essential to establish, using cone beam computed tomography (CBCT), the bone site and where to insert the implants; during the surgical phase, these sites must be identified on the oral mucosa. Surgical templates are a valid aid, especially in complex cases which require the insertion of more than three or four implants. In cases of a single implant, on the other hand, surgical guides are rarely used, and the implant is often inserted freehand; therefore, the identification of the implant site on the oral mucosa (after choosing the location on the CBCT) is more difficult. For this reason, the clinician uses the teeth in the arch as a reference. This study evaluates the ability of the human eye to identify, on the oral mucosa, where the implant collars will be positioned, the position of which has previously been chosen on the CBCT, in cases where the hands-free surgical technique (without surgical guides) is used. The verification of this precision is carried out using particular thermo-printed templates which contain radiopaque metal spheres. The results show that, in the freehand technique, it is difficult to precisely identify the implant sites (chosen via X-ray) on the mucosa, especially when they are far from natural teeth adjacent to the edentulous area. In case of monoedentulism, the freehand implant technique seems to be applicable by expert implantologists with a reduced risk of error; in fact, clinical experience helps to find the correct correspondence between the implant site chosen on the CBCT and its identification on the mucosa. The level of experience is fundamental in the clinician’s decision about whether or not to use surgical guides; in fact, doctors with little experience should use surgical guides even in the simplest cases to reduce the risk of error.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"30 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141117526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Analysis of Cemented and Cementless Straight-Stem Prostheses in Hip Replacement Surgery for Elderly Patients: A Mid-Term Follow-up Study 老年髋关节置换手术中的有骨水泥和无骨水泥直茎假体对比分析:中期随访研究
Pub Date : 2024-05-20 DOI: 10.3390/prosthesis6030038
M. Sapienza, Danilo Di Via, Marco Simone Vaccalluzzo, L. Costarella, V. Pavone, G. Testa
This retrospective cohort study assesses the effectiveness of straight-stem cementless versus cemented prostheses in hip replacement surgeries for elderly patients with femoral neck fractures. We analyzed 80 patients aged 70 and over who underwent surgery between 2018 and 2021. Clinical outcomes were evaluated using the Harris Hip Score, WOMAC Score, and Visual Analogue Scale, alongside radiological assessments through Brooker’s classification. Preoperative Dorr classification and five postoperative criteria (subsidence, cortical hypertrophy, pedestal sign, radiolucent lines, and stress shielding) were used to assess implant efficacy. The results demonstrated satisfactory mid-term outcomes for both groups, with slightly higher clinical scores observed in the cementless stem group. The Harris Hip Score (HHS) averaged 74.4 ± 6.7 in the cemented group and 79.2 ± 10.4 in the cementless group, with a statistically significant difference (p = 0.0146). The WOMAC Score showed an average of 30.1 ± 4.6 in the cemented group compared to 27.1 ± 6.9 in the cementless group, also indicating a statistically significant improvement (p = 0.0231). However, radiographic findings call for a re-evaluation of long-term stability. Our statistical analysis, which included power calculation and multivariate analysis to adjust for confounding variables, offers a comprehensive assessment of implant effectiveness. The findings contribute to the ongoing debate on the choice between cemented and cementless prostheses, indicating that both are viable options catering to different patient needs. Further research overcoming this study’s limitations is crucial for a deeper understanding of optimal treatment strategies in hip replacement surgery for the elderly.
这项回顾性队列研究评估了股骨颈骨折老年患者髋关节置换手术中直茎无骨水泥假体与骨水泥假体的有效性。我们分析了在 2018 年至 2021 年期间接受手术的 80 名 70 岁及以上的患者。临床结果采用哈里斯髋关节评分、WOMAC评分和视觉模拟量表进行评估,同时通过布罗克分类法进行放射学评估。术前 Dorr 分级和术后五项标准(下沉、皮质肥厚、基底征、放射线和应力屏蔽)用于评估植入物的疗效。结果显示,两组的中期疗效均令人满意,无骨水泥柄组的临床评分略高。有骨水泥组的 Harris 髋关节评分(HHS)平均为 74.4 ± 6.7,无骨水泥组为 79.2 ± 10.4,差异有统计学意义(p = 0.0146)。WOMAC评分显示,有骨水泥组平均为(30.1 ± 4.6)分,无骨水泥组为(27.1 ± 6.9)分,同样显示出统计学上的显著改善(p = 0.0231)。不过,放射学结果要求对长期稳定性进行重新评估。我们的统计分析包括功率计算和多变量分析,以调整混杂变量,从而对植入物的有效性进行全面评估。我们的研究结果有助于解决目前关于有骨水泥假体和无骨水泥假体之间选择的争论,表明这两种假体都是满足不同患者需求的可行选择。为了更深入地了解老年人髋关节置换手术的最佳治疗策略,进一步研究克服本研究的局限性至关重要。
{"title":"Comparative Analysis of Cemented and Cementless Straight-Stem Prostheses in Hip Replacement Surgery for Elderly Patients: A Mid-Term Follow-up Study","authors":"M. Sapienza, Danilo Di Via, Marco Simone Vaccalluzzo, L. Costarella, V. Pavone, G. Testa","doi":"10.3390/prosthesis6030038","DOIUrl":"https://doi.org/10.3390/prosthesis6030038","url":null,"abstract":"This retrospective cohort study assesses the effectiveness of straight-stem cementless versus cemented prostheses in hip replacement surgeries for elderly patients with femoral neck fractures. We analyzed 80 patients aged 70 and over who underwent surgery between 2018 and 2021. Clinical outcomes were evaluated using the Harris Hip Score, WOMAC Score, and Visual Analogue Scale, alongside radiological assessments through Brooker’s classification. Preoperative Dorr classification and five postoperative criteria (subsidence, cortical hypertrophy, pedestal sign, radiolucent lines, and stress shielding) were used to assess implant efficacy. The results demonstrated satisfactory mid-term outcomes for both groups, with slightly higher clinical scores observed in the cementless stem group. The Harris Hip Score (HHS) averaged 74.4 ± 6.7 in the cemented group and 79.2 ± 10.4 in the cementless group, with a statistically significant difference (p = 0.0146). The WOMAC Score showed an average of 30.1 ± 4.6 in the cemented group compared to 27.1 ± 6.9 in the cementless group, also indicating a statistically significant improvement (p = 0.0231). However, radiographic findings call for a re-evaluation of long-term stability. Our statistical analysis, which included power calculation and multivariate analysis to adjust for confounding variables, offers a comprehensive assessment of implant effectiveness. The findings contribute to the ongoing debate on the choice between cemented and cementless prostheses, indicating that both are viable options catering to different patient needs. Further research overcoming this study’s limitations is crucial for a deeper understanding of optimal treatment strategies in hip replacement surgery for the elderly.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"49 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141122246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Innovating Prosthodontic Rehabilitation: A Streamlined Two-Step Technique for Mobile Denture Fabrication 创新义齿修复:移动义齿制作的两步简化技术
Pub Date : 2024-05-14 DOI: 10.3390/prosthesis6030037
L. Fiorillo, C. D’amico, F. Gorassini, Marta Varrà, Emanuele Parbonetti, Salvatore Varrà, V. Ronsivalle, G. Cervino
This manuscript introduces a novel two-step technique for fabricating mobile dentures post-extraction to streamline prosthodontic rehabilitation. The study utilizes various materials, including dental polymers, metals, ceramics, and composite materials, each chosen for their unique properties that contribute to the final prosthesis’s functionality, durability, and esthetics. The detailed procedure involves an initial occlusal registration immediately following tooth extraction, capturing precise occlusal relationships and a comprehensive dental impression. This approach reduces clinical visits and leverages optimal alveolar ridge morphology. The expected results highlight the efficiency of the technique, reducing treatment time without compromising quality and potentially improving patient satisfaction and prosthodontic outcomes. This innovative method conclusively promises rapid, efficient, and patient-centered dental rehabilitation, emphasizing the need for future research to validate its effectiveness and explore long-term outcomes.
本手稿介绍了一种新颖的两步技术,用于制作拔牙后的活动假牙,以简化义齿修复。该研究使用了各种材料,包括牙科聚合物、金属、陶瓷和复合材料,每种材料都因其独特的性能而被选用,这些性能有助于最终义齿的功能性、耐用性和美观性。详细的程序包括拔牙后立即进行初步咬合登记,捕捉精确的咬合关系和全面的牙模。这种方法减少了临床就诊次数,并充分利用了最佳牙槽嵴形态。预期结果凸显了该技术的高效性,在不影响质量的前提下缩短了治疗时间,并有可能提高患者满意度和修复效果。这种创新方法有望实现快速、高效和以患者为中心的牙科康复,强调了未来研究验证其有效性和探索长期结果的必要性。
{"title":"Innovating Prosthodontic Rehabilitation: A Streamlined Two-Step Technique for Mobile Denture Fabrication","authors":"L. Fiorillo, C. D’amico, F. Gorassini, Marta Varrà, Emanuele Parbonetti, Salvatore Varrà, V. Ronsivalle, G. Cervino","doi":"10.3390/prosthesis6030037","DOIUrl":"https://doi.org/10.3390/prosthesis6030037","url":null,"abstract":"This manuscript introduces a novel two-step technique for fabricating mobile dentures post-extraction to streamline prosthodontic rehabilitation. The study utilizes various materials, including dental polymers, metals, ceramics, and composite materials, each chosen for their unique properties that contribute to the final prosthesis’s functionality, durability, and esthetics. The detailed procedure involves an initial occlusal registration immediately following tooth extraction, capturing precise occlusal relationships and a comprehensive dental impression. This approach reduces clinical visits and leverages optimal alveolar ridge morphology. The expected results highlight the efficiency of the technique, reducing treatment time without compromising quality and potentially improving patient satisfaction and prosthodontic outcomes. This innovative method conclusively promises rapid, efficient, and patient-centered dental rehabilitation, emphasizing the need for future research to validate its effectiveness and explore long-term outcomes.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"96 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140978412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigating Material Performance in Artificial Ankle Joints: A Biomechanical Study 人工踝关节材料性能调查:生物力学研究
Pub Date : 2024-05-13 DOI: 10.3390/prosthesis6030036
Hasan Mhd Nazha, Muhsen Adrah, Thaer Osman, Mohammad Issa, Ahmed Imran, Yicha Zhang, Daniel Juhre
This study delves into an in-depth examination of the biomechanical characteristics of various materials commonly utilized in the fabrication of artificial ankle joints. Specifically, this research focuses on the design of an ankle joint resembling the salto-talaris type, aiming to comprehensively understand its performance under different loading conditions. Employing advanced finite element analysis techniques, this investigation rigorously evaluates the stresses and displacements experienced by the designed ankle joint when subjected to varying loads. Furthermore, this study endeavors to identify the vibrating frequencies associated with these displacements, offering valuable insights into the dynamic behavior of the ankle joint. Notably, the analysis extends to studying random frequencies across three axes of motion, enabling a comprehensive assessment of directional deformities that may arise during joint function. To validate the effectiveness of the proposed design, a comparative analysis is conducted against the star ankle design, a widely recognized benchmark in ankle joint prosthetics. This comparative approach serves dual purposes: confirming the accuracy of the findings derived from the salto-talaris design and elucidating the relative efficacy of the proposed design in practical application scenarios.
本研究深入探讨了人工踝关节制造中常用的各种材料的生物力学特性。具体来说,本研究侧重于设计一个类似于 salto-talaris 型的踝关节,旨在全面了解其在不同负载条件下的性能。本研究采用先进的有限元分析技术,对所设计的踝关节在承受不同载荷时的应力和位移进行了严格评估。此外,这项研究还致力于确定与这些位移相关的振动频率,为了解踝关节的动态行为提供宝贵的见解。值得注意的是,分析扩展到研究三个运动轴的随机频率,从而能够全面评估关节功能过程中可能出现的定向变形。为了验证拟议设计的有效性,我们将踝关节设计与星形踝关节设计进行了对比分析,星形踝关节设计是公认的踝关节假体基准。这种对比方法有两个目的:确认从 salto-talaris 设计中得出的结论的准确性,以及阐明所建议的设计在实际应用场景中的相对有效性。
{"title":"Investigating Material Performance in Artificial Ankle Joints: A Biomechanical Study","authors":"Hasan Mhd Nazha, Muhsen Adrah, Thaer Osman, Mohammad Issa, Ahmed Imran, Yicha Zhang, Daniel Juhre","doi":"10.3390/prosthesis6030036","DOIUrl":"https://doi.org/10.3390/prosthesis6030036","url":null,"abstract":"This study delves into an in-depth examination of the biomechanical characteristics of various materials commonly utilized in the fabrication of artificial ankle joints. Specifically, this research focuses on the design of an ankle joint resembling the salto-talaris type, aiming to comprehensively understand its performance under different loading conditions. Employing advanced finite element analysis techniques, this investigation rigorously evaluates the stresses and displacements experienced by the designed ankle joint when subjected to varying loads. Furthermore, this study endeavors to identify the vibrating frequencies associated with these displacements, offering valuable insights into the dynamic behavior of the ankle joint. Notably, the analysis extends to studying random frequencies across three axes of motion, enabling a comprehensive assessment of directional deformities that may arise during joint function. To validate the effectiveness of the proposed design, a comparative analysis is conducted against the star ankle design, a widely recognized benchmark in ankle joint prosthetics. This comparative approach serves dual purposes: confirming the accuracy of the findings derived from the salto-talaris design and elucidating the relative efficacy of the proposed design in practical application scenarios.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"114 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140985707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Johann Wolfgang von Goethe, Götz von Berlichingen, and the „Iron Hands“ 约翰-沃尔夫冈-冯-歌德、戈兹-冯-伯利欣根和 "铁手"
Pub Date : 2024-05-09 DOI: 10.3390/prosthesis6030035
A. Otte
Knight Götz von Berlichingen (1480–1562) was born into a time of upheaval during the transition from the late Middle Ages to modern times [...]
骑士戈兹-冯-伯利欣根(1480-1562 年)出生在中世纪晚期向现代过渡的动荡时期 [...] 。
{"title":"Johann Wolfgang von Goethe, Götz von Berlichingen, and the „Iron Hands“","authors":"A. Otte","doi":"10.3390/prosthesis6030035","DOIUrl":"https://doi.org/10.3390/prosthesis6030035","url":null,"abstract":"Knight Götz von Berlichingen (1480–1562) was born into a time of upheaval during the transition from the late Middle Ages to modern times [...]","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 11","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140996131","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Prosthesis
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1