Pub Date : 2022-10-01DOI: 10.1213/XAA.0000000000001631
David B Pugh, Aakash Saxena, Lauren E Barta, Carolyn Pinkerton, Jurica Bajic, Brent T Boettcher, Harvey J Woehlck
A patient with gunshots within inches of the skin developed intraoperative vasodilatory hypotension and methemoglobinemia, both recognized consequences of nitrite poisoning. A 1- mg/kg dose of methylene blue transiently and partially reversed methemoglobinemia, but the color of the methylene blue faded rapidly, consistent with bleaching of methylene blue by nitrite in vivo. Methylene blue did not raise blood pressure, consistent with inhibition of nitric oxide (NO) synthase. Because NO production from nitrite uses an NO synthase (NOS)-independent pathway, methylene blue is expected to have little effect on reversing hypotension from nitrite poisoning. Consider nitrite toxicity in gunshot patients with refractory vasodilatory hypotension and elevated methemoglobin.
{"title":"A Case Report of Hypotension and Methemoglobinemia Associated With Gunshot Residue Poisoning: Nitrite-Induced Methemoglobinemia.","authors":"David B Pugh, Aakash Saxena, Lauren E Barta, Carolyn Pinkerton, Jurica Bajic, Brent T Boettcher, Harvey J Woehlck","doi":"10.1213/XAA.0000000000001631","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001631","url":null,"abstract":"<p><p>A patient with gunshots within inches of the skin developed intraoperative vasodilatory hypotension and methemoglobinemia, both recognized consequences of nitrite poisoning. A 1- mg/kg dose of methylene blue transiently and partially reversed methemoglobinemia, but the color of the methylene blue faded rapidly, consistent with bleaching of methylene blue by nitrite in vivo. Methylene blue did not raise blood pressure, consistent with inhibition of nitric oxide (NO) synthase. Because NO production from nitrite uses an NO synthase (NOS)-independent pathway, methylene blue is expected to have little effect on reversing hypotension from nitrite poisoning. Consider nitrite toxicity in gunshot patients with refractory vasodilatory hypotension and elevated methemoglobin.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 10","pages":"e01631"},"PeriodicalIF":0.5,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10480513","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-10-01DOI: 10.1213/XAA.0000000000001628
Su Min Quak, Shin Yuet Chong
Cutis aplasia is a rare condition characterized by skin and subcutaneous tissue defects. Researchers have previously described both conservative and surgical management methods. We report herein the case of a neonate with extensive cutis aplasia involving 37% of the total body surface area. Due to the risk of meningitis and catastrophic hemorrhage associated with scalp defects, she underwent staged surgical procedures with skin harvesting and synthetic skin application, followed by the application of cultured epithelial autografts. This report highlights the challenges in temperature and fluid management as well as intraoperative positioning in a neonate with cutis aplasia.
{"title":"Case Report: Anesthesia for a Neonate With Cutis Aplasia.","authors":"Su Min Quak, Shin Yuet Chong","doi":"10.1213/XAA.0000000000001628","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001628","url":null,"abstract":"<p><p>Cutis aplasia is a rare condition characterized by skin and subcutaneous tissue defects. Researchers have previously described both conservative and surgical management methods. We report herein the case of a neonate with extensive cutis aplasia involving 37% of the total body surface area. Due to the risk of meningitis and catastrophic hemorrhage associated with scalp defects, she underwent staged surgical procedures with skin harvesting and synthetic skin application, followed by the application of cultured epithelial autografts. This report highlights the challenges in temperature and fluid management as well as intraoperative positioning in a neonate with cutis aplasia.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 10","pages":"e01628"},"PeriodicalIF":0.5,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9192877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-10-01DOI: 10.1213/XAA.0000000000001627
Ali Hammoud, Elena Saade, Stéphanie Jarry, Sophie Baelen, Etienne J Couture, William Beaubien-Souligny, André Y Denault
Delirium is common in patients undergoing cardiac surgery, and venous congestion has been reported as an important risk factor. We report a 69-year-old patient who developed postoperative delirium in the intensive care unit following aortic valve replacement surgery. The postoperative course was complicated by delirium for which echographic signs of venous congestion on the portal and the renal but also the femoral veins and their resolution correlated with the course of delirium. The use of common femoral vein Doppler as a simple bedside technique to predict and identify congestive delirium has not been reported before.
{"title":"Pulsatile Femoral Vein Doppler and Congestive Delirium, What Is the Relationship?: A Case Report.","authors":"Ali Hammoud, Elena Saade, Stéphanie Jarry, Sophie Baelen, Etienne J Couture, William Beaubien-Souligny, André Y Denault","doi":"10.1213/XAA.0000000000001627","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001627","url":null,"abstract":"<p><p>Delirium is common in patients undergoing cardiac surgery, and venous congestion has been reported as an important risk factor. We report a 69-year-old patient who developed postoperative delirium in the intensive care unit following aortic valve replacement surgery. The postoperative course was complicated by delirium for which echographic signs of venous congestion on the portal and the renal but also the femoral veins and their resolution correlated with the course of delirium. The use of common femoral vein Doppler as a simple bedside technique to predict and identify congestive delirium has not been reported before.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 10","pages":"e01627"},"PeriodicalIF":0.5,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10480949","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Remimazolam is a recently approved benzodiazepine sedative. We report a case of a 72-year-old man who experienced a cardiac arrest due to severe anaphylaxis immediately after general anesthesia induction. Based on the results of skin tests, including those for dextran 40, an excipient in the remimazolam solution, and a review of drugs given during 3 anesthetics, remimazolam was identified as the probable causative agent. Although remimazolam is structurally similar to midazolam, the patient was not allergic to midazolam as demonstrated before and after anaphylaxis. This report highlights the potential risk of allergic reactions to remimazolam.
{"title":"Cardiac Arrest Following Remimazolam-Induced Anaphylaxis: A Case Report.","authors":"Yudai Hasushita, Megumi Nagao, Yoshihide Miyazawa, Kazuma Yunoki, Hiroyuki Mima","doi":"10.1213/XAA.0000000000001616","DOIUrl":"10.1213/XAA.0000000000001616","url":null,"abstract":"<p><p>Remimazolam is a recently approved benzodiazepine sedative. We report a case of a 72-year-old man who experienced a cardiac arrest due to severe anaphylaxis immediately after general anesthesia induction. Based on the results of skin tests, including those for dextran 40, an excipient in the remimazolam solution, and a review of drugs given during 3 anesthetics, remimazolam was identified as the probable causative agent. Although remimazolam is structurally similar to midazolam, the patient was not allergic to midazolam as demonstrated before and after anaphylaxis. This report highlights the potential risk of allergic reactions to remimazolam.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 9","pages":"e01616"},"PeriodicalIF":0.5,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d9/e6/acc-16-e01616.PMC9521581.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33479801","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-09-21eCollection Date: 2022-09-01DOI: 10.1213/XAA.0000000000001623
Hank C Wang, Andrew Auyeung, Tabish Aijaz, Kenneth D Candido, Nebojsa Nick Knezevic
Deep infections of spinal cord stimulator devices usually result in explantation, as recommended by some professional societies. However, alternative options should be explored to avoid potential complications that are associated with explantation, and possibly additional procedures required in consideration of reimplantation. In this case, the patient presented with wound dehiscence after implantation. There was suspicion for deep wound infection based on a wound culture that was positive for Staphylococcus aureus, but no purulent material was noted on further inspection. The patient was treated with standard wound-care management and oral antibiotics without removing the device, and recovered while preserving the original system.
{"title":"Dehiscence and Deep Wound Infection After Spinal Cord Stimulator Implant Managed Without Explantation: A Case Report.","authors":"Hank C Wang, Andrew Auyeung, Tabish Aijaz, Kenneth D Candido, Nebojsa Nick Knezevic","doi":"10.1213/XAA.0000000000001623","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001623","url":null,"abstract":"<p><p>Deep infections of spinal cord stimulator devices usually result in explantation, as recommended by some professional societies. However, alternative options should be explored to avoid potential complications that are associated with explantation, and possibly additional procedures required in consideration of reimplantation. In this case, the patient presented with wound dehiscence after implantation. There was suspicion for deep wound infection based on a wound culture that was positive for Staphylococcus aureus, but no purulent material was noted on further inspection. The patient was treated with standard wound-care management and oral antibiotics without removing the device, and recovered while preserving the original system.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 9","pages":"e01623"},"PeriodicalIF":0.5,"publicationDate":"2022-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33469795","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-09-21eCollection Date: 2022-09-01DOI: 10.1213/XAA.0000000000001622
Stephen F Woodford, Lachlan F Miles, Dong-Kyu Lee, Laurence Weinberg
The function of renal allografts in the perioperative period is partly dependent on minimizing hemodynamic instability. We have developed hemodynamic monitoring software-named the "pressure field"-that was utilized in a 68-year-old high-risk kidney transplant recipient. The "pressure field" was used to individualize fluid and drug administration and replicate the preoperative hemodynamics. The patient received net zero fluid intraoperatively and had an uneventful postoperative course. We found the pressure field method helpful to manage perioperative hemodynamics in this high-risk patient.
{"title":"A Software-Guided Approach to Hemodynamic Management in a Renal Transplant Recipient: A Case Report.","authors":"Stephen F Woodford, Lachlan F Miles, Dong-Kyu Lee, Laurence Weinberg","doi":"10.1213/XAA.0000000000001622","DOIUrl":"10.1213/XAA.0000000000001622","url":null,"abstract":"<p><p>The function of renal allografts in the perioperative period is partly dependent on minimizing hemodynamic instability. We have developed hemodynamic monitoring software-named the \"pressure field\"-that was utilized in a 68-year-old high-risk kidney transplant recipient. The \"pressure field\" was used to individualize fluid and drug administration and replicate the preoperative hemodynamics. The patient received net zero fluid intraoperatively and had an uneventful postoperative course. We found the pressure field method helpful to manage perioperative hemodynamics in this high-risk patient.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 9","pages":"e01622"},"PeriodicalIF":0.5,"publicationDate":"2022-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2d/31/acc-16-e01622.PMC9521586.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33479036","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-09-20eCollection Date: 2022-09-01DOI: 10.1213/XAA.0000000000001618
Samuel Ern Hung Tsan, Chin H Goh, Peter C S Tan
Ultrasound-guided scalp blocks may revolutionize regional anesthesia for neurosurgery. In this report, we demonstrate that ultrasound-guided scalp blocks can be used effectively for a craniotomy. A 48-year-old patient with a brain tumor at the motor cortex was scheduled for an awake craniotomy. Ultrasound-guided scalp blocks targeting the bilateral supraorbital, supratrochlear, zygomaticotemporal, auriculotemporal, greater auricular, lesser occipital, greater occipital, and third occipital nerves were performed. A total of 29 mL of levobupivacaine 0.3% was used. No additional local anesthetic agent was given for skull pinning, skin incision, or the craniotomy. Postoperatively, the patient remained pain-free, and she was discharged without complications.
{"title":"Ultrasound-Guided Scalp Blocks for an Awake Craniotomy: A Case Report.","authors":"Samuel Ern Hung Tsan, Chin H Goh, Peter C S Tan","doi":"10.1213/XAA.0000000000001618","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001618","url":null,"abstract":"<p><p>Ultrasound-guided scalp blocks may revolutionize regional anesthesia for neurosurgery. In this report, we demonstrate that ultrasound-guided scalp blocks can be used effectively for a craniotomy. A 48-year-old patient with a brain tumor at the motor cortex was scheduled for an awake craniotomy. Ultrasound-guided scalp blocks targeting the bilateral supraorbital, supratrochlear, zygomaticotemporal, auriculotemporal, greater auricular, lesser occipital, greater occipital, and third occipital nerves were performed. A total of 29 mL of levobupivacaine 0.3% was used. No additional local anesthetic agent was given for skull pinning, skin incision, or the craniotomy. Postoperatively, the patient remained pain-free, and she was discharged without complications.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 9","pages":"e01618"},"PeriodicalIF":0.5,"publicationDate":"2022-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33470469","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-09-09eCollection Date: 2022-09-01DOI: 10.1213/XAA.0000000000001615
Emma Möhlenkamp, Eva K Kohse, Phillip B Sasu, Tanja Peters, Jörn Grensemann, Philipp Breitfeld, Martin Petzoldt
This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.
{"title":"VivaSight Single-Lumen Tube Combined With Hyperangulated Videolaryngoscopy to Rescue Failed Tracheal Intubation in a Patient With Goldenhar Syndrome: A Case Report.","authors":"Emma Möhlenkamp, Eva K Kohse, Phillip B Sasu, Tanja Peters, Jörn Grensemann, Philipp Breitfeld, Martin Petzoldt","doi":"10.1213/XAA.0000000000001615","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001615","url":null,"abstract":"<p><p>This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 9","pages":"e01615"},"PeriodicalIF":0.5,"publicationDate":"2022-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33464954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-09-02eCollection Date: 2022-09-01DOI: 10.1213/XAA.0000000000001617
Christabel Jaiyeola, Amy Y Chen, Philip L Kalarickal, Binoy Praful Bhatt
In patients with cardiovascular implantable electronic devices, asynchronous pacing is necessary for surgeries with a risk of electromagnetic interference. Magnets are often used for asynchronous pacing. In this case report, magnet application to a Biotronik Evia DR-T pacemaker (Biotronik) programmed to a magnet response mode called automatic magnet mode (AUTO) led to a brief period of asynchronous pacing before reverting to prior settings, an unexpected response that was not revealed on the preoperative interrogation report. For Biotronik pacemakers programmed to the AUTO mode, changes in programming are needed for asynchronous pacing.
{"title":"An Unexpected Magnet Response of a Biotronik Pacemaker in Automatic Mode: A Case Report.","authors":"Christabel Jaiyeola, Amy Y Chen, Philip L Kalarickal, Binoy Praful Bhatt","doi":"10.1213/XAA.0000000000001617","DOIUrl":"10.1213/XAA.0000000000001617","url":null,"abstract":"In patients with cardiovascular implantable electronic devices, asynchronous pacing is necessary for surgeries with a risk of electromagnetic interference. Magnets are often used for asynchronous pacing. In this case report, magnet application to a Biotronik Evia DR-T pacemaker (Biotronik) programmed to a magnet response mode called automatic magnet mode (AUTO) led to a brief period of asynchronous pacing before reverting to prior settings, an unexpected response that was not revealed on the preoperative interrogation report. For Biotronik pacemakers programmed to the AUTO mode, changes in programming are needed for asynchronous pacing.","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":" ","pages":"e01617"},"PeriodicalIF":0.5,"publicationDate":"2022-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40353891","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2022-08-12eCollection Date: 2022-08-01DOI: 10.1213/XAA.0000000000001608
Tom Salih, Laura Elgie, Bindiya Hari, Bryn Williams, Richard M Thomas, Steve Bandula, Miles Walkden, Pervez Sultan, Kirstie McPherson, Kathryn Jenkins
High-frequency jet ventilation (HFJV) can reduce organ movement that otherwise complicates percutaneous image-guided ablation (IGA) procedures. This study describes feasibility and safety of the technique in routine use. We describe our method for the use of HFJV and present 169 consecutive cases, including IGA of tumors of the lung, liver, kidney, and pancreas. Intended oncological treatment was delivered in all cases and HFJV used for the duration of treatment in all except one case. We describe the characteristics of patients, procedures, and adverse events. It is feasible to use HFJV as the routine standard of care for IGA.
{"title":"In-Circuit High-Frequency Jet Ventilation for Radiological Tumor Ablation: A Case Series.","authors":"Tom Salih, Laura Elgie, Bindiya Hari, Bryn Williams, Richard M Thomas, Steve Bandula, Miles Walkden, Pervez Sultan, Kirstie McPherson, Kathryn Jenkins","doi":"10.1213/XAA.0000000000001608","DOIUrl":"https://doi.org/10.1213/XAA.0000000000001608","url":null,"abstract":"<p><p>High-frequency jet ventilation (HFJV) can reduce organ movement that otherwise complicates percutaneous image-guided ablation (IGA) procedures. This study describes feasibility and safety of the technique in routine use. We describe our method for the use of HFJV and present 169 consecutive cases, including IGA of tumors of the lung, liver, kidney, and pancreas. Intended oncological treatment was delivered in all cases and HFJV used for the duration of treatment in all except one case. We describe the characteristics of patients, procedures, and adverse events. It is feasible to use HFJV as the routine standard of care for IGA.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 8","pages":"e01608"},"PeriodicalIF":0.5,"publicationDate":"2022-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40607246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}