Pub Date : 2024-12-01Epub Date: 2024-12-30DOI: 10.13104/imri.2024.0009
Soham S More, Xiaoliang Zhang
Ultrashort echo time (UTE) and zero echo time (ZTE) imaging sequences have been developed to detect short T2 relaxation signals emanating from regions or tissues that conventional magnetic resonance imaging (MRI) methods fail to capture. Owing to the high dipole-dipole interactions in solid and semisolid tissues, the signal decay occurs very rapidly, typically in less than 1 ms. The echo time generated by conventional imaging methods is insufficiently short, resulting in void signals from these short-T2 species. The application of UTE and ZTE techniques enables the imaging of solid and semi-solid tissues, making the conventionally invisible visible, which can significantly impact clinical imaging. High- and ultra-high-field-strength (UHF) MRI offers a critical advantage in enhancing the sensitivity and specificity of MRI. When combined with UTE and ZTE sequences, it enables the recovery of signals from void areas and markedly improves signal quality. To bolster this approach and further validate the technique, while addressing its limitations, extensive efforts have been made to collect supplementary data using various research tools. Studies demonstrate that integrating UTE and ZTE sequences with advanced high and ultra-high field imaging techniques-particularly innovative developments in transmit/receive hardware, software, and novel trajectory approaches-plays a pivotal role in enhancing the clarity and accuracy of MRI for musculoskeletal, neural, lung, and dental applications.
{"title":"Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature Survey.","authors":"Soham S More, Xiaoliang Zhang","doi":"10.13104/imri.2024.0009","DOIUrl":"10.13104/imri.2024.0009","url":null,"abstract":"<p><p>Ultrashort echo time (UTE) and zero echo time (ZTE) imaging sequences have been developed to detect short T2 relaxation signals emanating from regions or tissues that conventional magnetic resonance imaging (MRI) methods fail to capture. Owing to the high dipole-dipole interactions in solid and semisolid tissues, the signal decay occurs very rapidly, typically in less than 1 ms. The echo time generated by conventional imaging methods is insufficiently short, resulting in void signals from these short-T2 species. The application of UTE and ZTE techniques enables the imaging of solid and semi-solid tissues, making the conventionally invisible visible, which can significantly impact clinical imaging. High- and ultra-high-field-strength (UHF) MRI offers a critical advantage in enhancing the sensitivity and specificity of MRI. When combined with UTE and ZTE sequences, it enables the recovery of signals from void areas and markedly improves signal quality. To bolster this approach and further validate the technique, while addressing its limitations, extensive efforts have been made to collect supplementary data using various research tools. Studies demonstrate that integrating UTE and ZTE sequences with advanced high and ultra-high field imaging techniques-particularly innovative developments in transmit/receive hardware, software, and novel trajectory approaches-plays a pivotal role in enhancing the clarity and accuracy of MRI for musculoskeletal, neural, lung, and dental applications.</p>","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"28 4","pages":"153-173"},"PeriodicalIF":0.0,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12685016/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145716858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sungtae Park, D. Han, Young-Nyun Park, Hyungjin Rhee
{"title":"An Incidentally Discovered Primary Hepatic Gastrointestinal Stromal Tumor Treated by Surgical Resection and Adjuvant Imatinib Therapy: A Case Report","authors":"Sungtae Park, D. Han, Young-Nyun Park, Hyungjin Rhee","doi":"10.13104/imri.2023.0004","DOIUrl":"https://doi.org/10.13104/imri.2023.0004","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"9 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66638350","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ye Ji, In Sook Lee, Y. Song, K. Nam, D. H. Kim, Kyung Un Choi
{"title":"Distinguishing CT and MR Imaging Features of Postprocedural Inflammation and Infectious Spondylodiscitis After Intradiscal Electrothermal Therapy","authors":"Ye Ji, In Sook Lee, Y. Song, K. Nam, D. H. Kim, Kyung Un Choi","doi":"10.13104/imri.2023.0010","DOIUrl":"https://doi.org/10.13104/imri.2023.0010","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66638592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jinho Yang, Subin Lee, Y. Moon, Jang-Sik Lee, W. Moon
{"title":"Relationship Between Cortical Iron and Diabetes Mellitus in Older Adults With Cognitive Complaints: A Quantitative Susceptibility Map Study","authors":"Jinho Yang, Subin Lee, Y. Moon, Jang-Sik Lee, W. Moon","doi":"10.13104/imri.2023.0002","DOIUrl":"https://doi.org/10.13104/imri.2023.0002","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66638792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Neuroimaging of Tactile Information Processing","authors":"Ji-Hyun Kim, Sung-Phil Kim","doi":"10.13104/imri.2022.1010","DOIUrl":"https://doi.org/10.13104/imri.2022.1010","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66634107","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
I. H. Chae, E. Cha, Jee Eun Lee, Jin Chung, Jeoung Hyun Kim, S. Sung, M. Han
{"title":"Response Evaluation to Neoadjuvant Chemotherapy in Breast Cancer Patients: Sequential Dynamic Contrast-Enhanced MRI Using Computer-Aided Detection","authors":"I. H. Chae, E. Cha, Jee Eun Lee, Jin Chung, Jeoung Hyun Kim, S. Sung, M. Han","doi":"10.13104/imri.2022.1001","DOIUrl":"https://doi.org/10.13104/imri.2022.1001","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66634284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Suchit Kumar, Jong-Min Kim, J. Cha, J. Hwang, S. Jung, Chulhyun Lee, Chang-Hyun Oh
{"title":"A Novel Magnetic Resonance Quality Assurance Phantom (KMRP-4): Multi-Site Comparison With the American College of Radiology Phantom","authors":"Suchit Kumar, Jong-Min Kim, J. Cha, J. Hwang, S. Jung, Chulhyun Lee, Chang-Hyun Oh","doi":"10.13104/imri.2022.1009","DOIUrl":"https://doi.org/10.13104/imri.2022.1009","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66633986","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Longitudinal Stress Fracture of the Ulna: Forearm Splint in a Military Cook With Wok Pot Use","authors":"J. Bae, Seul Ki Lee, Jee Young Kim, Jun-Ho Kim","doi":"10.13104/imri.2023.0003","DOIUrl":"https://doi.org/10.13104/imri.2023.0003","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66638340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Taehyeon Kim, Ji Young Kim, Young Jin Ryu, Hyeok Jin Hong
{"title":"Langerhans Cell Histiocytosis With Secondary Aneurysmal Bone Cyst in a 9-Year-Old Boy’s Femur: A Case Report","authors":"Taehyeon Kim, Ji Young Kim, Young Jin Ryu, Hyeok Jin Hong","doi":"10.13104/imri.2023.0009","DOIUrl":"https://doi.org/10.13104/imri.2023.0009","url":null,"abstract":"","PeriodicalId":73505,"journal":{"name":"Investigative magnetic resonance imaging","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66638457","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}