首页 > 最新文献

Brazilian dental journal最新文献

英文 中文
EGFR, VEGF, and angiogenesis promote the development of lipoma in the oral cavity. EGFR, VEGF和血管新生促进口腔脂肪瘤的发展。
Q2 Medicine Pub Date : 2023-03-01 DOI: 10.1590/0103-6440202305117
Weslay Rodrigues da Silva, Hévila de Figueiredo Pires, Glória Maria de França, Roseana de Almeida Freitas, Hannah Gil de Farias Morais, Hébel Cavalcanti Galvão

This study aimed to detect, quantify and compare the immunohistochemical expression of EGFR and VEGF and microvessel count (MVC) in oral lipomas, and to correlate the findings with clinical and morphological characteristics of the cases studied. The sample consisted of 54 oral lipomas (33 classic and 21 non-classic) and 23 normal adipose tissue specimens. Cytoplasmic and/or nuclear immunohistochemical staining of EGFR and VEGF was analyzed. The angiogenic index was determined by MVC. Cells were counted using the Image J® software. The Statistical Package for the Social Sciences was used for data analysis, adopting a level of significance of 5% for all statistical tests. A statistically significant difference in EGFR immunoexpression (p=0.047), especially, between classic lipomas and normal adipose tissue. There was a significant difference in MVC between non-classic lipomas and normal adipose tissue (p=0.022). In non-classic lipomas, only VEGF immunoexpression showed a significant moderate positive correlation (r=0.607, p=0.01) with MVC. In classic lipomas, the number of EGFR-immunostained adipocytes was directly proportional to the number of VEGF-positive cells, demonstrating a significant moderate positive correlation (r=0.566, p=0.005). The results suggest that EGFR, VEGF, and angiogenesis participate in the development of oral lipomas but are not primarily involved in the growth of these tumors.

本研究旨在检测、量化和比较口腔脂肪瘤中EGFR和VEGF的免疫组化表达和微血管计数(MVC),并将其与所研究病例的临床和形态学特征联系起来。样本包括54例口腔脂肪瘤(33例典型和21例非典型)和23例正常脂肪组织标本。分析EGFR和VEGF的细胞质和/或核免疫组化染色。采用MVC法测定血管生成指数。使用Image J®软件对细胞进行计数。使用社会科学统计软件包进行数据分析,对所有统计检验采用5%的显著性水平。EGFR免疫表达差异有统计学意义(p=0.047),特别是在典型脂肪瘤和正常脂肪组织之间。非典型脂肪瘤与正常脂肪组织的MVC差异有统计学意义(p=0.022)。在非典型脂肪瘤中,只有VEGF免疫表达与MVC呈显著的中度正相关(r=0.607, p=0.01)。在典型脂肪瘤中,egfr免疫染色脂肪细胞的数量与vegf阳性细胞的数量成正比,呈显著的中度正相关(r=0.566, p=0.005)。结果表明,EGFR、VEGF和血管生成参与了口腔脂肪瘤的发展,但并不主要参与这些肿瘤的生长。
{"title":"EGFR, VEGF, and angiogenesis promote the development of lipoma in the oral cavity.","authors":"Weslay Rodrigues da Silva,&nbsp;Hévila de Figueiredo Pires,&nbsp;Glória Maria de França,&nbsp;Roseana de Almeida Freitas,&nbsp;Hannah Gil de Farias Morais,&nbsp;Hébel Cavalcanti Galvão","doi":"10.1590/0103-6440202305117","DOIUrl":"https://doi.org/10.1590/0103-6440202305117","url":null,"abstract":"<p><p>This study aimed to detect, quantify and compare the immunohistochemical expression of EGFR and VEGF and microvessel count (MVC) in oral lipomas, and to correlate the findings with clinical and morphological characteristics of the cases studied. The sample consisted of 54 oral lipomas (33 classic and 21 non-classic) and 23 normal adipose tissue specimens. Cytoplasmic and/or nuclear immunohistochemical staining of EGFR and VEGF was analyzed. The angiogenic index was determined by MVC. Cells were counted using the Image J® software. The Statistical Package for the Social Sciences was used for data analysis, adopting a level of significance of 5% for all statistical tests. A statistically significant difference in EGFR immunoexpression (p=0.047), especially, between classic lipomas and normal adipose tissue. There was a significant difference in MVC between non-classic lipomas and normal adipose tissue (p=0.022). In non-classic lipomas, only VEGF immunoexpression showed a significant moderate positive correlation (r=0.607, p=0.01) with MVC. In classic lipomas, the number of EGFR-immunostained adipocytes was directly proportional to the number of VEGF-positive cells, demonstrating a significant moderate positive correlation (r=0.566, p=0.005). The results suggest that EGFR, VEGF, and angiogenesis participate in the development of oral lipomas but are not primarily involved in the growth of these tumors.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 2","pages":"113-121"},"PeriodicalIF":0.0,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208286/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9520402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Low concentrations of grape seed extract maintain osteoblast morphology, cell adhesion, and mineralization. 低浓度的葡萄籽提取物维持成骨细胞形态、细胞粘附和矿化。
Q2 Medicine Pub Date : 2023-03-01 DOI: 10.1590/0103-6440202304987
Maria Carolina Coelho, Viviann Ruocco Vetucci, Roger Rodrigo Fernandes, Paula Katherine Vargas Sanchez, Selma Siessere, Karina Fittipaldi Bombonato-Prado

The increase in life expectancy has led to a higher incidence of osteoporosis, characterized by an imbalance in bone remodeling. Several drugs are used for its treatment, but most promote undesirable side effects. The present investigation evaluated the effects of two low concentrations of grape seed extract (GSE) rich in proanthocyanidins on MC3T3-E1 osteoblastic cells. The cells were cultured in an osteogenic medium and divided into control (C), 0.1 µg/mL GSE (GSE0.1), and 1.0 µg/mL GSE (GSE1.0) groups to evaluate cell morphology, adhesion, and proliferation, in situ alkaline phosphatase (ALP) detection, mineralization and immunolocalization of osteopontin (OPN). The data obtained were analyzed by statistical tests for a significance of 5%. Cell morphology was maintained with both GSE concentrations, whereas cell adhesion significantly increased within three days in all groups. Cell proliferation increased significantly at seven days of culture, followed by a significant decrease in all experimental periods, with no statistical difference among them. In situ detection of ALP and mineralization increased with time, but within each period, no statistical differences among groups were observed. The expression of osteopontin was distributed regularly with more intensity after 24 hours in the GSE0.1 group. After three days, OPN expression was more intense in the control group, followed by GSE0.1 and GSE1.0 groups. Data obtained suggest that low concentrations of GSE do not affect the morphology and may stimulate the functional activity of osteoblastic cells.

预期寿命的增加导致骨质疏松症的发病率增加,其特征是骨骼重塑的不平衡。有几种药物用于治疗,但大多数药物都会产生不良副作用。本研究评估了两种低浓度富含原花青素的葡萄籽提取物(GSE)对MC3T3-E1成骨细胞的影响。细胞在成骨培养基中培养,分为对照(C)、0.1µg/mL GSE (GSE0.1)和1.0µg/mL GSE (GSE1.0)组,评估细胞形态、粘附、增殖、原位碱性磷酸酶(ALP)检测、骨桥蛋白(OPN)矿化和免疫定位。所得数据经统计学检验分析,显著性为5%。两种浓度的GSE均能维持细胞形态,3 d内细胞黏附均显著增加。培养第7天细胞增殖显著增加,之后各实验时期细胞增殖均显著降低,各实验时期细胞增殖均无统计学差异。ALP和矿化的原位检测随时间的增加而增加,但各时间段内各组间差异无统计学意义。GSE0.1组骨桥蛋白表达在24h后呈规律性分布,表达强度增大。3 d后,对照组的OPN表达较强烈,其次为GSE0.1和GSE1.0组。结果表明,低浓度的GSE不影响成骨细胞的形态,并可能刺激成骨细胞的功能活性。
{"title":"Low concentrations of grape seed extract maintain osteoblast morphology, cell adhesion, and mineralization.","authors":"Maria Carolina Coelho,&nbsp;Viviann Ruocco Vetucci,&nbsp;Roger Rodrigo Fernandes,&nbsp;Paula Katherine Vargas Sanchez,&nbsp;Selma Siessere,&nbsp;Karina Fittipaldi Bombonato-Prado","doi":"10.1590/0103-6440202304987","DOIUrl":"https://doi.org/10.1590/0103-6440202304987","url":null,"abstract":"<p><p>The increase in life expectancy has led to a higher incidence of osteoporosis, characterized by an imbalance in bone remodeling. Several drugs are used for its treatment, but most promote undesirable side effects. The present investigation evaluated the effects of two low concentrations of grape seed extract (GSE) rich in proanthocyanidins on MC3T3-E1 osteoblastic cells. The cells were cultured in an osteogenic medium and divided into control (C), 0.1 µg/mL GSE (GSE0.1), and 1.0 µg/mL GSE (GSE1.0) groups to evaluate cell morphology, adhesion, and proliferation, in situ alkaline phosphatase (ALP) detection, mineralization and immunolocalization of osteopontin (OPN). The data obtained were analyzed by statistical tests for a significance of 5%. Cell morphology was maintained with both GSE concentrations, whereas cell adhesion significantly increased within three days in all groups. Cell proliferation increased significantly at seven days of culture, followed by a significant decrease in all experimental periods, with no statistical difference among them. In situ detection of ALP and mineralization increased with time, but within each period, no statistical differences among groups were observed. The expression of osteopontin was distributed regularly with more intensity after 24 hours in the GSE0.1 group. After three days, OPN expression was more intense in the control group, followed by GSE0.1 and GSE1.0 groups. Data obtained suggest that low concentrations of GSE do not affect the morphology and may stimulate the functional activity of osteoblastic cells.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 2","pages":"97-104"},"PeriodicalIF":0.0,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208284/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9521780","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation. 辅助器械自动制备长椭圆形根管的优化研究。
Q2 Medicine Pub Date : 2023-03-01 DOI: 10.1590/0103-6440202305231
Marco Antonio Castro-Perez, Cleber Keiti Nabeshima, Emmanuel J N L Silva, José Edgar Valdivia, Giulio Gavini, Manoel Eduardo de Lima Machado

This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.

本研究比较了使用WaveOne Gold和XP-endo Shaper系统制备长椭圆形根管的情况,两者都辅以或不辅以人工器械。24根长椭圆形的下切牙根管根据器械的不同分为WaveOne Gold Primary和XP-endo Shaper两组。所有的根管在自动准备后都手工用25k大小的锉进行根管预备。在自动制备和人工检测前后,采用微ct(17.42µm)扫描。评估了增加的根管表面和未触及区域的百分比。WaveOne Gold和XP-endo Shaper系统均增加了根管表面,且未触及面积相似(p>0.05)。辅助器械增加了根管表面,减少了未触及的管壁(p
{"title":"Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation.","authors":"Marco Antonio Castro-Perez,&nbsp;Cleber Keiti Nabeshima,&nbsp;Emmanuel J N L Silva,&nbsp;José Edgar Valdivia,&nbsp;Giulio Gavini,&nbsp;Manoel Eduardo de Lima Machado","doi":"10.1590/0103-6440202305231","DOIUrl":"https://doi.org/10.1590/0103-6440202305231","url":null,"abstract":"<p><p>This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 2","pages":"35-40"},"PeriodicalIF":0.0,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208298/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9513648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors. X-Smart Plus, VDW的实际速度和设定速度之间的旋转运动学评估。银色和iRoot电机。
Q2 Medicine Pub Date : 2023-03-01 DOI: 10.1590/0103-6440202304953
Renata de Castro Monteiro-Netto, Dieimes Braambati, Rodrigo Arruda-Vasconcelos, Adriana de-Jesus Soares, Marcos Frozoni

The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm2 torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.

本研究评估了三种不同牙髓马达的实际转速,并与制造商提供的数值进行了比较。共有3台牙髓马达(X-Smart Plus、VDW、VDW、VDW)。Silver和iRoot分别在400 rpm和800 rpm和2 N/cm2的扭矩下进行了测试。设备的运动是通过使用制造商提供的附着在手机上的直径为50毫米的定制角度测量盘来记录的,而它们的运动是由高速摄像机以每秒2400帧,800 x 800像素的分辨率和距离目标物体0.3 m的距离来捕捉的。统计学分析为显著性水平5%。在400转时,iRoot电机的转速比制造商指示的转速高17.94转,与X-Smart Plus的转速(比制造商指示的转速低5.20转)和VDW有显著差异。银色(0.62 rpm以上制造商指示)电机(P < 0.05)。在800 rpm时,iRoot电机的转速比制造商指示的转速低51.34 rpm,而X-Smart Plus电机的转速比制造商指示的转速低13.00 rpm (P > 0.05)。就是secu * tanu减去VDW的。Silver电机的转速与iRoot和X-Smart Plus的转速在统计上有所不同,比制造商提供的转速高1.68 rpm。总之,X-Smart Plus, VDW。与制造商报告的转速值相比,Silver和iRoot电机的转速值变化较小。牙髓马达表现出不同的行为,与VDW一致。银电机呈现最准确的值,iRoot呈现最发散的值。
{"title":"Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors.","authors":"Renata de Castro Monteiro-Netto,&nbsp;Dieimes Braambati,&nbsp;Rodrigo Arruda-Vasconcelos,&nbsp;Adriana de-Jesus Soares,&nbsp;Marcos Frozoni","doi":"10.1590/0103-6440202304953","DOIUrl":"https://doi.org/10.1590/0103-6440202304953","url":null,"abstract":"<p><p>The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm2 torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 2","pages":"21-26"},"PeriodicalIF":0.0,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208292/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9513649","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of temperature on the torsional properties of two thermally treated NiTi rotary instruments 温度对两种热处理镍钛旋转仪表扭转性能的影响
Q2 Medicine Pub Date : 2023-02-01 DOI: 10.11606/d.25.2020.tde-26102021-101827
Roberto Barreto Osaki, C. Bramante, R. Vivan, M. Alcalde, P. Calefi, M. Duarte
Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.
摘要本研究旨在评估温度对两种具有相同截面的蓝色和金色热处理的NiTi旋转仪器的扭转强度和角挠度的影响。共使用40台实验NiTi仪器(25.06,三角形截面,蓝色和金色热处理)。根据ISO 3630-1,在距仪器尖端3mm处进行扭转测试。扭转试验评估了在室温(21°C±1°C)和体温(36°C±1°C)下的扭转强度和角挠度到失效。利用扫描电子显微镜(SEM)观察了每个碎片的断裂表面。数据分析采用非配对t检验进行组间和组内比较,显著性水平设为5%。结果表明,与室温相比,体温对器械的扭转强度和角挠度没有影响(P < 0.05)。然而,在体温下,蓝色NiTi仪器的角度偏转明显低于金色NiTi仪器(P0.05)。温度对采用蓝金技术制造的仪器的抗扭强度没有影响。然而,在36°C温度下,蓝色NiTi仪器的角偏转明显低于金色仪器。
{"title":"Influence of temperature on the torsional properties of two thermally treated NiTi rotary instruments","authors":"Roberto Barreto Osaki, C. Bramante, R. Vivan, M. Alcalde, P. Calefi, M. Duarte","doi":"10.11606/d.25.2020.tde-26102021-101827","DOIUrl":"https://doi.org/10.11606/d.25.2020.tde-26102021-101827","url":null,"abstract":"Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"12 - 18"},"PeriodicalIF":0.0,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44976684","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Amalgam x Composite Resin: supplies and restorative procedures more performed among Oral Health Teams in Brazil Amalgam x复合树脂:巴西口腔健康团队更多地进行补给品和恢复程序
Q2 Medicine Pub Date : 2023-01-15 DOI: 10.1590/0103-6440202305003
M. Silva-Júnior, Elis Carolina Pacheco, N. Bastos-Bitencourt, Pollyana Kassia de Oliveira Borges, M. H. Baldani
Abstract This study aimed to compare the availability of supplies and amalgam and composite resin restorations among Oral Health Teams (OHT) in Brazilian regions. Secondary data were extracted from Modules I and II of the 1st (2012) and V and VI of the 2nd (2014) and 3rd cycle (2017) of the external evaluation of the National Program for Access and Quality in Primary Care2. The proportions between regions and cycles were compared using the Chi-square test with the z-test adjusted by the Bonferroni method (p<0.05). Among 2012, 2014, and 2017 there was a significant reduction in the proportion of OHT that performed amalgam restorations (87.5%, 89.2%, and 80.2%; p<0.001) and an increase in resin composite (92.5 %, 97.7%, and 99.0%; p<0.001), with the same trend in Brazilian regions (p<0.001). Amalgamator availability decreased among 2012 (99.0%), 2014 (98.4%) and 2017 (85.6%) (p<0.001). Amalgam availability was lower in 2017 (80.1%), compared to 2012 (87.5%) and 2014 (97.5%) (p<0.001). The availability of light curing decreased between 2012 (99.0%), 2014 (98.4%) and 2017 (85.6%) (p<0.001), being less available in the North (95.7%) (p<0.001). The light-curing resin increased between 2012 (94.1%), 2014 (96.6%) and 2017 (97.0%) (p<0.001), with no increase only in the North (p=0.134). While there was a reduction in supplies and amalgam restoration, there was an increase in supplies and resin composite restorations in the period evaluated in all Brazilian regions. However, regional disparities are still evident, with fewer supplies of restorative services in the North region.
摘要:本研究旨在比较巴西地区口腔卫生团队(OHT)的供应和汞合金和复合树脂修复体的可用性。二级数据摘自国家初级保健可及性和质量规划外部评估第一期(2012年)模块1和模块2,第二期(2014年)和第三期(2017年)模块5和模块6。区域与周期之间的比例比较采用卡方检验和经Bonferroni方法调整的z检验(p<0.05)。2012年、2014年和2017年,采用汞合金修复的OHT比例显著下降(87.5%、89.2%和80.2%;P <0.001)和树脂复合材料的增加(92.5%,97.7%和99.0%;p<0.001),巴西地区的趋势也相同(p<0.001)。合并器可用性在2012年(99.0%)、2014年(98.4%)和2017年(85.6%)下降(p<0.001)。与2012年(87.5%)和2014年(97.5%)相比,2017年汞合金的可用性(80.1%)较低(p<0.001)。光固化的可用性在2012年(99.0%)、2014年(98.4%)和2017年(85.6%)之间下降(p<0.001),北方的可用性较低(95.7%)(p<0.001)。光固化树脂在2012年(94.1%)、2014年(96.6%)和2017年(97.0%)期间均有增加(p<0.001),只有北方地区没有增加(p=0.134)。虽然供应和汞合金修复有所减少,但在评估期间巴西所有区域的供应和树脂复合修复有所增加。但是,区域差异仍然很明显,北部地区提供的恢复性服务较少。
{"title":"Amalgam x Composite Resin: supplies and restorative procedures more performed among Oral Health Teams in Brazil","authors":"M. Silva-Júnior, Elis Carolina Pacheco, N. Bastos-Bitencourt, Pollyana Kassia de Oliveira Borges, M. H. Baldani","doi":"10.1590/0103-6440202305003","DOIUrl":"https://doi.org/10.1590/0103-6440202305003","url":null,"abstract":"Abstract This study aimed to compare the availability of supplies and amalgam and composite resin restorations among Oral Health Teams (OHT) in Brazilian regions. Secondary data were extracted from Modules I and II of the 1st (2012) and V and VI of the 2nd (2014) and 3rd cycle (2017) of the external evaluation of the National Program for Access and Quality in Primary Care2. The proportions between regions and cycles were compared using the Chi-square test with the z-test adjusted by the Bonferroni method (p<0.05). Among 2012, 2014, and 2017 there was a significant reduction in the proportion of OHT that performed amalgam restorations (87.5%, 89.2%, and 80.2%; p<0.001) and an increase in resin composite (92.5 %, 97.7%, and 99.0%; p<0.001), with the same trend in Brazilian regions (p<0.001). Amalgamator availability decreased among 2012 (99.0%), 2014 (98.4%) and 2017 (85.6%) (p<0.001). Amalgam availability was lower in 2017 (80.1%), compared to 2012 (87.5%) and 2014 (97.5%) (p<0.001). The availability of light curing decreased between 2012 (99.0%), 2014 (98.4%) and 2017 (85.6%) (p<0.001), being less available in the North (95.7%) (p<0.001). The light-curing resin increased between 2012 (94.1%), 2014 (96.6%) and 2017 (97.0%) (p<0.001), with no increase only in the North (p=0.134). While there was a reduction in supplies and amalgam restoration, there was an increase in supplies and resin composite restorations in the period evaluated in all Brazilian regions. However, regional disparities are still evident, with fewer supplies of restorative services in the North region.","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"75 - 87"},"PeriodicalIF":0.0,"publicationDate":"2023-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46151946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Tomographic, microbiological and histological characterization of secondary apical periodontitis: case series. 继发性根尖牙周炎的断层摄影、微生物学和组织学特征:病例系列。
Q2 Medicine Pub Date : 2023-01-01 DOI: 10.1590/0103-6440202304590
Marla Mora-Carabalí, Adolfo Contreras, Patricia Rodríguez, Ingrid Zamora, Martha Rodríguez

This case series included a tomographic, microbiological, and histopathological description of 15 secondary apical periodontitis (SAP) lesions obtained by apical microsurgery performed in 10 patients to better understand the etiology and pathogenesis of SAP. Preoperative tomographic analyses were performed through Cone beam computerized tomography - Periapical index (CBCT-PAI), and apical microsurgeries were then carried out. The removed apices were used for microbial culturing and for molecular identification using PCR for the detection of 5 strict anaerobic bacteria (P. gingivalis, P. intermedia, P. nigrescens, T. forsythia, and T.denticola) and 3 viruses Herpes simplex viruses (HSV), Cytomegalovirus (CMG) and Epstein-Barr Virus (EBV) by nested PCR. The removed apical lesions were histologically described. Univariate statistical analyses were performed by using STATA MP/16 (StataCorp LLC, College Station, TX, United States). CBCT-PAI analyses revealed PAI 4 and PAI 5 score lesions that involved cortical plate destruction. Eight SAPs were positive by culture, while nine SAP lesions were positive by PCR. Fusobacterium species were the most frequently cultured organisms in 7 SAP lesions, followed by D. pneumosintes in 3. In contrast, by single PCR, T. forsythia and P. nigrescens were detected in 5 lesions, T. denticola in 4 lesions, and P. gingivalis in 2 lesions. Twelve periapical lesions were granulomas, and the remaining three SAP lesions were radicular cysts. In conclusion, this case series study revealed that secondary apical lesions presented tomographic involvement of PAI 3 to 5, and that most SAP lesions were apical granulomas containing anaerobic and facultative microorganisms.

为了更好地了解继发性根尖牙周炎(SAP)的病因和发病机制,本病例系列包括对10例患者根尖显微手术获得的15例继发性根尖牙周炎(SAP)病变的断层扫描、微生物学和组织病理学描述。术前通过锥形束计算机断层扫描-根尖周指数(CBCT-PAI)进行断层扫描分析,然后进行根尖显微手术。将取下的根尖进行微生物培养和分子PCR鉴定,采用巢式PCR法检测5种严格厌氧菌(牙龈假单胞菌、中间假单胞菌、黑根假单胞菌、连翘假单胞菌和齿状假单胞菌)和3种病毒(单纯疱疹病毒、巨细胞病毒和eb病毒)。对切除的根尖病变进行组织学描述。采用STATA MP/16 (StataCorp LLC, College Station, TX, United States)进行单变量统计分析。CBCT-PAI分析显示PAI 4和PAI 5评分病变涉及皮质板破坏。8例SAP培养阳性,9例SAP病变PCR阳性。7例SAP病变中培养最多的是梭杆菌,3例次之。相比之下,单次PCR检测到连翘和黑根假单胞菌5例,齿状假单胞菌4例,牙龈假单胞菌2例。根尖周围病变12例为肉芽肿,其余3例为根状囊肿。总之,本病例系列研究显示继发性根尖病变表现为PAI 3至5的断层扫描累及,大多数SAP病变为含有厌氧和兼性微生物的根尖肉芽肿。
{"title":"Tomographic, microbiological and histological characterization of secondary apical periodontitis: case series.","authors":"Marla Mora-Carabalí,&nbsp;Adolfo Contreras,&nbsp;Patricia Rodríguez,&nbsp;Ingrid Zamora,&nbsp;Martha Rodríguez","doi":"10.1590/0103-6440202304590","DOIUrl":"https://doi.org/10.1590/0103-6440202304590","url":null,"abstract":"<p><p>This case series included a tomographic, microbiological, and histopathological description of 15 secondary apical periodontitis (SAP) lesions obtained by apical microsurgery performed in 10 patients to better understand the etiology and pathogenesis of SAP. Preoperative tomographic analyses were performed through Cone beam computerized tomography - Periapical index (CBCT-PAI), and apical microsurgeries were then carried out. The removed apices were used for microbial culturing and for molecular identification using PCR for the detection of 5 strict anaerobic bacteria (P. gingivalis, P. intermedia, P. nigrescens, T. forsythia, and T.denticola) and 3 viruses Herpes simplex viruses (HSV), Cytomegalovirus (CMG) and Epstein-Barr Virus (EBV) by nested PCR. The removed apical lesions were histologically described. Univariate statistical analyses were performed by using STATA MP/16 (StataCorp LLC, College Station, TX, United States). CBCT-PAI analyses revealed PAI 4 and PAI 5 score lesions that involved cortical plate destruction. Eight SAPs were positive by culture, while nine SAP lesions were positive by PCR. Fusobacterium species were the most frequently cultured organisms in 7 SAP lesions, followed by D. pneumosintes in 3. In contrast, by single PCR, T. forsythia and P. nigrescens were detected in 5 lesions, T. denticola in 4 lesions, and P. gingivalis in 2 lesions. Twelve periapical lesions were granulomas, and the remaining three SAP lesions were radicular cysts. In conclusion, this case series study revealed that secondary apical lesions presented tomographic involvement of PAI 3 to 5, and that most SAP lesions were apical granulomas containing anaerobic and facultative microorganisms.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"123-132"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027100/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9149339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Semantic equivalence of the Brazilian version of the Patient Satisfaction Questionnaire (B-PSQ). 巴西版患者满意度问卷(B-PSQ)的语义等价性。
Q2 Medicine Pub Date : 2023-01-01 DOI: 10.1590/0103-6440202305074
Luisa Gatti-Reis, Renata Negreiros Alvarenga, Lucas Guimarães Abreu, Saul Martins Paiva

The Patient Satisfaction Questionnaire (PSQ) is a self-administered instrument to assess adolescent patients' satisfaction with orthodontic treatment. A pre-existing North American instrument was further explored in the Netherlands. Semantic equivalence is part of cross-cultural adaptation and is necessary to achieve a valid and reliable instrument for a specific culture. The present study aimed to evaluate the semantic equivalence of the items, subscales, and overall PSQ between the original English version and the Brazilian Portuguese language version (B-PSQ). The PSQ has 58 items, distributed across 6 subscales: doctor-patient relationship, situational aspects of the clinic, dentofacial improvement, psychosocial improvement, dental function, and a residual category. Semantic equivalence was evaluated according to the following methods: (1) independent translations to Portuguese by two translators, both native in Brazilian Portuguese and fluent in English; (2) an expert committee drafted the first summarized version in Portuguese; (3) two independent back-translations into English by two native English-speaking translators fluent in Portuguese; (4) committee review; (5) committee drafted a summarized version of the back-translations; (6) expert committee drafted the second summarized version in Portuguese; (7) pre-test of the instrument using individual semi-structured interviews with 10 adolescents; (8) review and final version of the B-PSQ. Semantic equivalence between the original and the Brazilian versions of the questionnaire was achieved through diligent and rigorous methods, with effective translation and expert evaluations, incorporating the opinions of the target population.

患者满意度问卷(PSQ)是一种评估青少年患者对正畸治疗满意度的自我管理工具。在荷兰进一步探索了一种北美已有的乐器。语义对等是跨文化适应的一部分,是实现对特定文化的有效和可靠的工具所必需的。本研究旨在评估原英语版本和巴西葡萄牙语版本(B-PSQ)的项目、分量表和总体PSQ的语义等效性。PSQ有58个项目,分布在6个子量表中:医患关系、诊所情境方面、牙面改善、心理社会改善、牙齿功能和剩余类别。根据以下方法评估语义等价性:(1)由两名母语为巴西葡萄牙语且英语流利的译员独立翻译成葡萄牙语;(2)一个专家委员会用葡萄牙语起草了第一个摘要版本;(3)由两名葡萄牙语流利的英语母语翻译人员独立反译成英文;(四)委员会审查;(5)委员会起草了一份总结版的反译稿;(6)专家委员会以葡萄牙语起草第二份摘要文本;(7)对10名青少年进行半结构化访谈,对该工具进行预测试;(8) B-PSQ的评审和最终版本。通过勤奋严谨的方法,通过有效的翻译和专家评估,结合目标人群的意见,实现了原始问卷和巴西版本之间的语义对等。
{"title":"Semantic equivalence of the Brazilian version of the Patient Satisfaction Questionnaire (B-PSQ).","authors":"Luisa Gatti-Reis,&nbsp;Renata Negreiros Alvarenga,&nbsp;Lucas Guimarães Abreu,&nbsp;Saul Martins Paiva","doi":"10.1590/0103-6440202305074","DOIUrl":"https://doi.org/10.1590/0103-6440202305074","url":null,"abstract":"<p><p>The Patient Satisfaction Questionnaire (PSQ) is a self-administered instrument to assess adolescent patients' satisfaction with orthodontic treatment. A pre-existing North American instrument was further explored in the Netherlands. Semantic equivalence is part of cross-cultural adaptation and is necessary to achieve a valid and reliable instrument for a specific culture. The present study aimed to evaluate the semantic equivalence of the items, subscales, and overall PSQ between the original English version and the Brazilian Portuguese language version (B-PSQ). The PSQ has 58 items, distributed across 6 subscales: doctor-patient relationship, situational aspects of the clinic, dentofacial improvement, psychosocial improvement, dental function, and a residual category. Semantic equivalence was evaluated according to the following methods: (1) independent translations to Portuguese by two translators, both native in Brazilian Portuguese and fluent in English; (2) an expert committee drafted the first summarized version in Portuguese; (3) two independent back-translations into English by two native English-speaking translators fluent in Portuguese; (4) committee review; (5) committee drafted a summarized version of the back-translations; (6) expert committee drafted the second summarized version in Portuguese; (7) pre-test of the instrument using individual semi-structured interviews with 10 adolescents; (8) review and final version of the B-PSQ. Semantic equivalence between the original and the Brazilian versions of the questionnaire was achieved through diligent and rigorous methods, with effective translation and expert evaluations, incorporating the opinions of the target population.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"107-122"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027093/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9149340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effects of BlueM® against Streptococcus mutans biofilm and its virulence gene expression. BlueM®抗变形链球菌生物膜及其毒力基因表达的影响。
Q2 Medicine Pub Date : 2023-01-01 DOI: 10.1590/0103-6440202305133
Veronica Canela Estevam Dos Santos, Patricia Milagros Maquera-Huacho, Maria Júlia Mancim Imbriani, Vivian M Tellaroli Rodrigues Minhaco, Denise M Palomari Spolidorio

This study evaluated the antimicrobial capacity of BlueM® mouthwash against the bacterium Streptococcus mutans and its influence on gbpA gene expression as well as its cytotoxic effect on fibroblast cells. BlueM® showed antimicrobial activity, with MIC and MBC values of 0.005% and 0.01%, respectively. The MBIC was 6.25% for S. mutans. CFU count and confocal microscopy revealed significant effect of BlueM® on S. mutans biofilm pre-formed on dentin surfaces. Interestingly, the analysis of gbpA gene expression indicated a decrease in gene expression after 15 min of treatment with BlueM® at a concentration of 25%. Moreover, BlueM® exhibited low levels of cytotoxicity. In conclusion, our results showed the antimicrobial effectiveness of BlueM® against S. mutans, its ability to modulate the expression of the gbpA gene and its low cytotoxicity. This study supports the therapeutic potential of BlueM® as an alternative agent for the control of oral biofilm.

本研究评估了BlueM®漱口水对变形链球菌的抑菌能力、对gbpA基因表达的影响以及对成纤维细胞的细胞毒作用。BlueM®具有抗菌活性,MIC和MBC分别为0.005%和0.01%。变形链球菌的MBIC为6.25%。CFU计数和共聚焦显微镜显示BlueM®对牙本质表面预形成的变形链球菌生物膜有显著的影响。有趣的是,gbpA基因表达分析显示,用浓度为25%的BlueM®治疗15分钟后,基因表达下降。此外,BlueM®表现出低水平的细胞毒性。总之,我们的研究结果显示了BlueM®对变形链球菌的抗菌效果,其调节gbpA基因表达的能力和低细胞毒性。这项研究支持了BlueM®作为控制口腔生物膜的替代药物的治疗潜力。
{"title":"Effects of BlueM® against Streptococcus mutans biofilm and its virulence gene expression.","authors":"Veronica Canela Estevam Dos Santos,&nbsp;Patricia Milagros Maquera-Huacho,&nbsp;Maria Júlia Mancim Imbriani,&nbsp;Vivian M Tellaroli Rodrigues Minhaco,&nbsp;Denise M Palomari Spolidorio","doi":"10.1590/0103-6440202305133","DOIUrl":"https://doi.org/10.1590/0103-6440202305133","url":null,"abstract":"<p><p>This study evaluated the antimicrobial capacity of BlueM® mouthwash against the bacterium Streptococcus mutans and its influence on gbpA gene expression as well as its cytotoxic effect on fibroblast cells. BlueM® showed antimicrobial activity, with MIC and MBC values of 0.005% and 0.01%, respectively. The MBIC was 6.25% for S. mutans. CFU count and confocal microscopy revealed significant effect of BlueM® on S. mutans biofilm pre-formed on dentin surfaces. Interestingly, the analysis of gbpA gene expression indicated a decrease in gene expression after 15 min of treatment with BlueM® at a concentration of 25%. Moreover, BlueM® exhibited low levels of cytotoxicity. In conclusion, our results showed the antimicrobial effectiveness of BlueM® against S. mutans, its ability to modulate the expression of the gbpA gene and its low cytotoxicity. This study supports the therapeutic potential of BlueM® as an alternative agent for the control of oral biofilm.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"19-28"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027103/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9149341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Failure behavior of zirconia crowns subjected to air abrasion with different particle sizes. 氧化锆冠在不同粒度空气磨蚀下的失效行为。
Q2 Medicine Pub Date : 2023-01-01 DOI: 10.1590/0103-6440202304998
João Cézar Mosele, Andressa Restani Oliveira, Gabriela Pizzolatto, Paula Benetti, Marcia Borba

This study aimed to investigate the failure behavior of 3 mol.% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) prosthetic crowns air-abraded with aluminum oxide (AO) particles of different sizes. Ninety ceramic premolar crowns were produced with 3Y-TZP frameworks veneered with porcelain. Crowns were randomly divided into three groups, according to the size of the air abrasion AO particles (n = 30): (GC) untreated (control); (G53) 53 µm; (G125) 125 µm. Air abrasion was performed with 0.25 mpa pressure, 10-mm distance, for 10 s. Crowns were adhesively cemented to dentin analog abutments. Specimens were loaded in compression to failure, in 37oC distilled water, using a universal testing machine (n = 30). Fractographic analysis was performed using a stereomicroscope and SEM. The roughness of the crown's inner surface was evaluated using an optical profilometer (n = 10). Fracture load data were statistically analyzed with Weibull analysis and roughness data with Kruskal-Wallis (α = 0.05). GC had the lowest characteristic fracture load (L0), while G53 and G125 had higher and statistically similar L0 values. The Weibull modulus (m) was similar among groups. The failure modes observed were catastrophic failure and porcelain chipping. There were no differences between the roughness parameters for the experimental groups (p > 0.05). The size of the AO particles did not affect the fracture load and failure mode of 3Y-TZP crowns. Air abrasion with 53 µm and 125 µm particles resulted in a higher fracture load of ceramic crowns than the untreated group while maintaining their reliability and surface characteristics.

本研究旨在探讨用不同大小的氧化铝(AO)颗粒进行空气焙烧的 3 mol.% 稳定钇四方氧化锆多晶体(3Y-TZP)修复冠的失效行为。使用瓷贴面的 3Y-TZP 框架制作了 90 个陶瓷前臼齿修复冠。根据气磨氧化铝颗粒的大小(n = 30),牙冠被随机分为三组:(GC) 未经处理(对照组);(G53) 53 µm;(G125) 125 µm。气磨的压力为 0.25 mpa,距离为 10 mm,持续时间为 10 s。使用万能试验机(n = 30)在 37°C 的蒸馏水中对试样进行压缩加载至破坏。使用体视显微镜和扫描电镜进行断面分析。使用光学轮廓仪评估了牙冠内表面的粗糙度(n = 10)。断裂载荷数据采用 Weibull 分析法进行统计分析,粗糙度数据采用 Kruskal-Wallis 分析法进行统计分析(α = 0.05)。GC 的特征断裂载荷(L0)最低,而 G53 和 G125 的 L0 值较高,且在统计上相似。各组的威布尔模量(m)相似。观察到的破坏模式为灾难性破坏和瓷崩裂。各实验组的粗糙度参数之间没有差异(p > 0.05)。AO 颗粒的大小对 3Y-TZP 牙冠的断裂载荷和破坏模式没有影响。使用 53 微米和 125 微米颗粒进行气磨后,陶瓷冠的断裂负荷高于未处理组,但仍能保持其可靠性和表面特征。
{"title":"Failure behavior of zirconia crowns subjected to air abrasion with different particle sizes.","authors":"João Cézar Mosele, Andressa Restani Oliveira, Gabriela Pizzolatto, Paula Benetti, Marcia Borba","doi":"10.1590/0103-6440202304998","DOIUrl":"10.1590/0103-6440202304998","url":null,"abstract":"<p><p>This study aimed to investigate the failure behavior of 3 mol.% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) prosthetic crowns air-abraded with aluminum oxide (AO) particles of different sizes. Ninety ceramic premolar crowns were produced with 3Y-TZP frameworks veneered with porcelain. Crowns were randomly divided into three groups, according to the size of the air abrasion AO particles (n = 30): (GC) untreated (control); (G53) 53 µm; (G125) 125 µm. Air abrasion was performed with 0.25 mpa pressure, 10-mm distance, for 10 s. Crowns were adhesively cemented to dentin analog abutments. Specimens were loaded in compression to failure, in 37oC distilled water, using a universal testing machine (n = 30). Fractographic analysis was performed using a stereomicroscope and SEM. The roughness of the crown's inner surface was evaluated using an optical profilometer (n = 10). Fracture load data were statistically analyzed with Weibull analysis and roughness data with Kruskal-Wallis (α = 0.05). GC had the lowest characteristic fracture load (L0), while G53 and G125 had higher and statistically similar L0 values. The Weibull modulus (m) was similar among groups. The failure modes observed were catastrophic failure and porcelain chipping. There were no differences between the roughness parameters for the experimental groups (p > 0.05). The size of the AO particles did not affect the fracture load and failure mode of 3Y-TZP crowns. Air abrasion with 53 µm and 125 µm particles resulted in a higher fracture load of ceramic crowns than the untreated group while maintaining their reliability and surface characteristics.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"71-79"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027107/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9153291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Brazilian dental journal
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1