Initial evaluation of the Indiana small animal PET scanner 印第安纳州小动物PET扫描仪的初步评估
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596815
N. Rouze, V.C. Soon, J. Young, S. Siegel, G. Hutchins
The Indiana small animal PET scanner is a new generation PET scanner with design goals of 1 microliter volumetric spatial resolution, a point source sensitivity of greater than 5 percent, and an imaging field-of-view suitable for whole body mouse imaging. The scanner design uses 12 planar detector banks each consisting of a 48 /spl times/ 108 array of 20 mm long LSO crystals with an array pitch of 0.87 mm coupled to two Hamamatsu H8500 large area, 64-anode photomultiplier tubes. The detector modules are mounted on a rotatable gantry and are offset from the center of rotation to give an increased sampling density. Eight detector banks are currently installed in the scanner, and this report presents an initial performance evaluation of the scanner for this configuration. Using a 30 gauge needle (ID=0.15 mm, OD=0.30 mm) positioned near the center of the scanner, the transaxial resolution has been measured to be 1.1 mm FWHM and the axial resolution has been measured to be 1.5 mm FWHM. The sensitivity has been measured to be 4.0% of all decays. The scatter fraction is 0.26 and the peak noise equivalent countrate is 80 kcps at an activity of 0.22 mCi. Sample images demonstrate good imaging capabilities.
印第安纳小动物PET扫描仪是新一代PET扫描仪,设计目标为1微升体积空间分辨率,点源灵敏度大于5%,成像视野适合全身小鼠成像。扫描仪设计使用12个平面探测器组,每个探测器组由48 /spl倍/ 108阵列的20 mm长LSO晶体组成,阵列间距为0.87 mm,耦合到两个Hamamatsu H8500大面积64阳极光电倍增管。探测器模块安装在一个可旋转的龙门架上,并从旋转中心偏移,以增加采样密度。目前在扫描仪中安装了8个检测器组,本报告介绍了该配置下扫描仪的初步性能评估。使用一根30号针(内径=0.15 mm,外径=0.30 mm)定位在扫描仪中心附近,测得跨轴分辨率为1.1 mm FWHM,轴向分辨率为1.5 mm FWHM。测量的灵敏度为所有衰减的4.0%。在0.22 mCi的活度下,散射分数为0.26,峰值噪声当量为80 kcps。示例图像展示了良好的成像能力。
{"title":"Initial evaluation of the Indiana small animal PET scanner","authors":"N. Rouze, V.C. Soon, J. Young, S. Siegel, G. Hutchins","doi":"10.1109/NSSMIC.2005.1596815","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596815","url":null,"abstract":"The Indiana small animal PET scanner is a new generation PET scanner with design goals of 1 microliter volumetric spatial resolution, a point source sensitivity of greater than 5 percent, and an imaging field-of-view suitable for whole body mouse imaging. The scanner design uses 12 planar detector banks each consisting of a 48 /spl times/ 108 array of 20 mm long LSO crystals with an array pitch of 0.87 mm coupled to two Hamamatsu H8500 large area, 64-anode photomultiplier tubes. The detector modules are mounted on a rotatable gantry and are offset from the center of rotation to give an increased sampling density. Eight detector banks are currently installed in the scanner, and this report presents an initial performance evaluation of the scanner for this configuration. Using a 30 gauge needle (ID=0.15 mm, OD=0.30 mm) positioned near the center of the scanner, the transaxial resolution has been measured to be 1.1 mm FWHM and the axial resolution has been measured to be 1.5 mm FWHM. The sensitivity has been measured to be 4.0% of all decays. The scatter fraction is 0.26 and the peak noise equivalent countrate is 80 kcps at an activity of 0.22 mCi. Sample images demonstrate good imaging capabilities.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121122585","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
High resolution GSO block detectors using PMT-quadrant-sharing design for human whole body and breast/brain PET applications 采用pmt象限共享设计的高分辨率GSO块检测器,适用于人体全身和乳房/脑部PET应用
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596929
Soonseok Kim, W. Wong, Hongdi Li, Yuxuan Zhang, S. Xie, R. Ramirez, Yu Wang, J. Uribe, H. Baghaei, Jiguo Liu, Shitao Liu
High resolution GSO block detectors have been developed using the PMT-quadrant-sharing (PQS) design for human whole body and breast/brain PET applications. Segmented GSO (Ce 0.5 mol%) crystals of 3.02 mmtimes3.02 mmtimes20 mm (13times13 array) and 3.58 mmtimes3.58 mmtimes20 mm (11times11) were assembled together to build two prototype detectors for whole body PET imaging with 39 mm round PMTs and crystals of 2.04 mmtimes2.04 mmtimes20 mm (9times9) for breast/brain PET imaging with 19 mm round PMTs. The enhanced specular reflector (3M Co.) mirror-film windows with reflectance 98% and thickness 0.065 mm were used to control light collection and distribution. Crystal pitches are 3.1 (13times13), 3.64 (11times11), and 2.12 mm (9times9) and crystal-packing fractions are 95, 97, and 93%, respectively. List-mode measurements with Cs-137 sources were carried out to investigate crystal decoding and were analyzed to extract individual crystal spectra. All the crystals in the detectors were identified. Energy resolution for individual crystals ranges from 13.7 to 18.5% (13times13), 12.2 to 14.2% (11times11), and 20.9 to 28.9% (9times9), with overall energy resolutions of 15.6, 13.2, and 24.3%, respectively. Light collection efficiencies for the central crystals are 60 (13times13), 66 (11times11), and 72% (9times9), compared to the corner crystals. The maximum decodable crystals/PMT ratios at 511 keV are high 121-169 for the 39 mm PQS GSO detector design and 81 for the 19 mm PQS GSO detector design with crystals 20 mm deep. It is anticipated that these PQS GSO detectors will provide high resolution and sensitivity at low cost
采用pmt象限共享(PQS)设计开发了高分辨率GSO块检测器,用于人体全身和乳腺/脑PET应用。将分割成3.02 mmtimes3.02 mmtimes20 mm (13times13阵列)和3.58 mmtimes3.58 mmtimes20 mm (11times11)的GSO (Ce 0.5 mol%)晶体组装在一起,构建了两个原型探测器,分别用于39 mm圆形PMTs的全身PET成像和2.04 mmtimes2.04 mmtimes20 mm (9times9)的晶体用于19 mm圆形PMTs的乳腺/脑PET成像。采用3M公司的增强型镜面反射窗,反射率为98%,厚度为0.065 mm,用于控制光的收集和分布。晶体间距分别为3.1(13倍13)、3.64(11倍11)和2.12 mm(9倍9),结晶率分别为95.0%、97%和93%。利用Cs-137源进行列表模式测量以研究晶体解码,并分析提取单个晶体光谱。探测器中的所有晶体都被鉴定出来了。单个晶体的能量分辨率分别为13.7 ~ 18.5%(13倍13)、12.2 ~ 14.2%(11倍11)和20.9 ~ 28.9%(9倍9),总能量分辨率分别为15.6%、13.2和24.3%。与角落晶体相比,中心晶体的光收集效率分别为60(13倍13)、66(11倍11)和72%(9倍9)。在511 keV时,39 mm PQS GSO探测器设计的最大可解码晶体/PMT比率为121-169,而晶体深度为20 mm的19 mm PQS GSO探测器设计的最大可解码晶体/PMT比率为81。预计这些PQS GSO探测器将以低成本提供高分辨率和高灵敏度
{"title":"High resolution GSO block detectors using PMT-quadrant-sharing design for human whole body and breast/brain PET applications","authors":"Soonseok Kim, W. Wong, Hongdi Li, Yuxuan Zhang, S. Xie, R. Ramirez, Yu Wang, J. Uribe, H. Baghaei, Jiguo Liu, Shitao Liu","doi":"10.1109/NSSMIC.2005.1596929","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596929","url":null,"abstract":"High resolution GSO block detectors have been developed using the PMT-quadrant-sharing (PQS) design for human whole body and breast/brain PET applications. Segmented GSO (Ce 0.5 mol%) crystals of 3.02 mmtimes3.02 mmtimes20 mm (13times13 array) and 3.58 mmtimes3.58 mmtimes20 mm (11times11) were assembled together to build two prototype detectors for whole body PET imaging with 39 mm round PMTs and crystals of 2.04 mmtimes2.04 mmtimes20 mm (9times9) for breast/brain PET imaging with 19 mm round PMTs. The enhanced specular reflector (3M Co.) mirror-film windows with reflectance 98% and thickness 0.065 mm were used to control light collection and distribution. Crystal pitches are 3.1 (13times13), 3.64 (11times11), and 2.12 mm (9times9) and crystal-packing fractions are 95, 97, and 93%, respectively. List-mode measurements with Cs-137 sources were carried out to investigate crystal decoding and were analyzed to extract individual crystal spectra. All the crystals in the detectors were identified. Energy resolution for individual crystals ranges from 13.7 to 18.5% (13times13), 12.2 to 14.2% (11times11), and 20.9 to 28.9% (9times9), with overall energy resolutions of 15.6, 13.2, and 24.3%, respectively. Light collection efficiencies for the central crystals are 60 (13times13), 66 (11times11), and 72% (9times9), compared to the corner crystals. The maximum decodable crystals/PMT ratios at 511 keV are high 121-169 for the 39 mm PQS GSO detector design and 81 for the 19 mm PQS GSO detector design with crystals 20 mm deep. It is anticipated that these PQS GSO detectors will provide high resolution and sensitivity at low cost","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125698108","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of a fully rotational non-contact fluorescence tomographer for small animals 小动物全旋转非接触荧光层析仪的研制
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596814
R. Schulz, G. Echner, H. Ruhle, W. Stroh, J. Vierling, T. Vogt, J. Peter, W. Semmler
We present herein the development of a fully 360/spl deg/ rotatable fluorescence tomography system for small animals without the use of source and detector fibers, or optically matching fluids. The setup consists of a cooled CCD camera coupled to a wide-angle objective and an axially moveable, collimated laser source integrated within a rotating light-tight chamber. The system's capability to acquire and reconstruct high density datasets is demonstrated with experimental results from phantoms.
我们在此提出了一种完全360/spl度/可旋转的小动物荧光断层扫描系统的发展,而不使用源和检测器纤维,或光学匹配流体。该装置由一个与广角物镜耦合的冷却CCD相机和一个轴向可移动的准直激光源组成,该激光源集成在一个旋转的防光室中。实验结果表明,该系统具有获取和重建高密度数据集的能力。
{"title":"Development of a fully rotational non-contact fluorescence tomographer for small animals","authors":"R. Schulz, G. Echner, H. Ruhle, W. Stroh, J. Vierling, T. Vogt, J. Peter, W. Semmler","doi":"10.1109/NSSMIC.2005.1596814","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596814","url":null,"abstract":"We present herein the development of a fully 360/spl deg/ rotatable fluorescence tomography system for small animals without the use of source and detector fibers, or optically matching fluids. The setup consists of a cooled CCD camera coupled to a wide-angle objective and an axially moveable, collimated laser source integrated within a rotating light-tight chamber. The system's capability to acquire and reconstruct high density datasets is demonstrated with experimental results from phantoms.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133526881","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
MCNP prediction of measured subcritical reactor parameters 测量的亚临界反应堆参数的MCNP预测
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596394
Ned Xoubi, Zhong‐Kuo Zhao, G. Maldonado
At the University of Cincinnati Nuclear Engineering Program, the resurrection of a once moth-balled subcritical reactor facility now provides an ideal laboratory experience to its students. Its simplicity and accessibility are among its key features. This article focuses upon supplementing the experimental aspects of this facility via the development of a three-dimensional, full detail, MCNP model of this reactor, while emphasizing the validation of this computational tool against laboratory measurements. The subcritical reactor parameters herein compared include: neutron and photon flux distributions, fission rate, and the subcritical multiplication factor (k-effective), among other relevant parameters of interest
在辛辛那提大学核工程项目中,一个曾经被封存的亚临界反应堆设施的复活现在为学生提供了一个理想的实验室体验。它的简单性和可访问性是其主要特性之一。本文的重点是通过开发该反应堆的三维、全细节、MCNP模型来补充该设施的实验方面,同时强调该计算工具对实验室测量的验证。本文比较的亚临界反应堆参数包括:中子和光子通量分布、裂变速率、亚临界倍增因子(k-effective)以及其他相关参数
{"title":"MCNP prediction of measured subcritical reactor parameters","authors":"Ned Xoubi, Zhong‐Kuo Zhao, G. Maldonado","doi":"10.1109/NSSMIC.2005.1596394","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596394","url":null,"abstract":"At the University of Cincinnati Nuclear Engineering Program, the resurrection of a once moth-balled subcritical reactor facility now provides an ideal laboratory experience to its students. Its simplicity and accessibility are among its key features. This article focuses upon supplementing the experimental aspects of this facility via the development of a three-dimensional, full detail, MCNP model of this reactor, while emphasizing the validation of this computational tool against laboratory measurements. The subcritical reactor parameters herein compared include: neutron and photon flux distributions, fission rate, and the subcritical multiplication factor (k-effective), among other relevant parameters of interest","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131865955","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Performance characteristics of continuous miniature crystal element (cMiCE) detectors 连续微型晶元(cMiCE)探测器的性能特性
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596622
T. Ling, Kisung Lee, R. Miyaoka
In this work, we investigate the performance characteristics of our continuous miniature crystal element detector (cMiCE). Versions with a 25 mm by 25 mm by 4 mm thick LSO crystal and with a 50 mm by 50 mm by 8 mm thick LSYO crystal were evaluated. Both detectors utilized a 64-channel flat panel photomultiplier tube (PMT). The intrinsic spatial resolution for the detectors was evaluated using standard Anger positioning and a statistics based positioning (SBP) algorithm. We also examined the effect different reflective materials applied on the entrance surface had on the intrinsic resolution for the 8 mm LYSO crystal. The average energy resolution was 20% for the 4 mm thick LSO crystal and 16% - 21% for the 8 mm thick LYSO crystal. The average intrinsic spatial resolution for the 4 mm thick crystal was 1.8 mm full width at half maximum (FWHM) for Anger positioning to within 3 mm of the crystal's edge and 1.14 mm FWHM for SBP to within 2 mm of the edge. The average intrinsic spatial resolution for the 8 mm thick crystal was 2.2 mm FWHM for Anger positioning to within 8 mm of the crystal's edge and 1.3-1.5 mm FWHM (depending on the reflective material used) for SBP to within 2 mm of the edge. Intrinsic spatial resolution is reported without correcting for point source size. The point spot flux had a FWHM of -0.52 mm. Using the SBP algorithm showed significant improvement in spatial resolution, linearity of positioning result, and effective field of view for our cMiCE detector
在这项工作中,我们研究了我们的连续微型晶体元件检测器(cMiCE)的性能特征。采用25毫米× 25毫米× 4毫米厚的LSO晶体和50毫米× 50毫米× 8毫米厚的LSYO晶体进行了评估。两个探测器都使用了64通道平板光电倍增管(PMT)。利用标准Anger定位和基于统计的定位(SBP)算法对探测器的固有空间分辨率进行了评估。我们还研究了施加在入口表面的不同反射材料对8mm LYSO晶体固有分辨率的影响。4mm厚LYSO晶体的平均能量分辨率为20%,8mm厚LYSO晶体的平均能量分辨率为16% - 21%。当Anger定位到晶体边缘3 mm以内时,4 mm厚晶体的平均固有空间分辨率为1.8 mm,当SBP定位到晶体边缘2 mm以内时,平均固有空间分辨率为1.14 mm。8mm厚晶体的平均固有空间分辨率在Anger定位到晶体边缘8 mm以内时为2.2 mm FWHM,在SBP定位到边缘2 mm以内时为1.3-1.5 mm FWHM(取决于所使用的反射材料)。报告的内在空间分辨率没有对点源大小进行校正。点光斑通量的FWHM为-0.52 mm。采用SBP算法后,cMiCE探测器的空间分辨率、定位结果的线性度和有效视场均有显著提高
{"title":"Performance characteristics of continuous miniature crystal element (cMiCE) detectors","authors":"T. Ling, Kisung Lee, R. Miyaoka","doi":"10.1109/NSSMIC.2005.1596622","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596622","url":null,"abstract":"In this work, we investigate the performance characteristics of our continuous miniature crystal element detector (cMiCE). Versions with a 25 mm by 25 mm by 4 mm thick LSO crystal and with a 50 mm by 50 mm by 8 mm thick LSYO crystal were evaluated. Both detectors utilized a 64-channel flat panel photomultiplier tube (PMT). The intrinsic spatial resolution for the detectors was evaluated using standard Anger positioning and a statistics based positioning (SBP) algorithm. We also examined the effect different reflective materials applied on the entrance surface had on the intrinsic resolution for the 8 mm LYSO crystal. The average energy resolution was 20% for the 4 mm thick LSO crystal and 16% - 21% for the 8 mm thick LYSO crystal. The average intrinsic spatial resolution for the 4 mm thick crystal was 1.8 mm full width at half maximum (FWHM) for Anger positioning to within 3 mm of the crystal's edge and 1.14 mm FWHM for SBP to within 2 mm of the edge. The average intrinsic spatial resolution for the 8 mm thick crystal was 2.2 mm FWHM for Anger positioning to within 8 mm of the crystal's edge and 1.3-1.5 mm FWHM (depending on the reflective material used) for SBP to within 2 mm of the edge. Intrinsic spatial resolution is reported without correcting for point source size. The point spot flux had a FWHM of -0.52 mm. Using the SBP algorithm showed significant improvement in spatial resolution, linearity of positioning result, and effective field of view for our cMiCE detector","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"16 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123663784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
SPECT-CT study of directed drug delivery using /sup 111/In-labeled liposomes in a murine mammary carcinoma model 使用/sup 111/ in标记脂质体在小鼠乳腺癌模型中定向给药的SPECT-CT研究
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596717
E. Izaguirre, Mingshan Sun, D. Drummond, D. Kirpotin, T. Funk, S. Thompson, J. Carver, M. Hayes, M. Wendland, M. Knudsen, B. Hasegawa
Liposomal drugs offer the promise of an improved therapeutic index due to improvements in the specific delivery of anti-cancer agents to tumors. The presented work concentrates on imaging the tumor uptake of /sup 111/In-labeled liposomes noninvasively as a specific tumor drug delivery carrier in a murine cancer model. The tumor uptake of liposomes has been imaged using a microSPECT/microCT small animal dedicated scanner prototype constructed at our laboratory. The imaging system consists of a high resolution SPECT (700 /spl mu/m) and high resolution CT (70 /spl mu/m). The SPECT subsystem consists in specially designed CZT gamma cameras shielded for energies up to 250 keV. The mice were injected with liposomes and scanned at the time of maximum tumor uptake (24 h). The total activity of the mouse samples was of the order of 250 uCi, and with tumor sizes of 1000-1500 mm/sup 3/. The imaging geometries in the CT and SPECT acquisitions were selected to obtain high magnification and high efficiency to image the tumor located within the torso. The SPECT and CT projections were taken sequentially. The acquired images show that necrotic tumors can de imaged with high resolution to observe liposome inhomogeneous uptake.
由于改善了抗癌药物对肿瘤的特异性递送,脂质体药物提供了改善治疗指数的希望。目前的工作集中在成像肿瘤摄取/sup 111/ in标记脂质体作为一个特定的肿瘤药物递送载体在小鼠癌症模型中无创。肿瘤对脂质体的摄取使用我们实验室构建的微spect /微ct小动物专用扫描仪原型进行了成像。成像系统由高分辨率SPECT (700 /spl mu/m)和高分辨率CT (70 /spl mu/m)组成。SPECT子系统包括特别设计的CZT伽玛相机屏蔽能量高达250千伏特。给小鼠注射脂质体,并在最大肿瘤摄取时间(24 h)进行扫描。小鼠样品的总活性约为250 uCi,肿瘤大小为1000-1500 mm/sup 3/。选择CT和SPECT成像几何形状以获得高倍率和高效率来成像位于躯干内的肿瘤。依次进行SPECT和CT投影。获得的图像显示,坏死肿瘤可以用高分辨率成像,观察脂质体的不均匀摄取。
{"title":"SPECT-CT study of directed drug delivery using /sup 111/In-labeled liposomes in a murine mammary carcinoma model","authors":"E. Izaguirre, Mingshan Sun, D. Drummond, D. Kirpotin, T. Funk, S. Thompson, J. Carver, M. Hayes, M. Wendland, M. Knudsen, B. Hasegawa","doi":"10.1109/NSSMIC.2005.1596717","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596717","url":null,"abstract":"Liposomal drugs offer the promise of an improved therapeutic index due to improvements in the specific delivery of anti-cancer agents to tumors. The presented work concentrates on imaging the tumor uptake of /sup 111/In-labeled liposomes noninvasively as a specific tumor drug delivery carrier in a murine cancer model. The tumor uptake of liposomes has been imaged using a microSPECT/microCT small animal dedicated scanner prototype constructed at our laboratory. The imaging system consists of a high resolution SPECT (700 /spl mu/m) and high resolution CT (70 /spl mu/m). The SPECT subsystem consists in specially designed CZT gamma cameras shielded for energies up to 250 keV. The mice were injected with liposomes and scanned at the time of maximum tumor uptake (24 h). The total activity of the mouse samples was of the order of 250 uCi, and with tumor sizes of 1000-1500 mm/sup 3/. The imaging geometries in the CT and SPECT acquisitions were selected to obtain high magnification and high efficiency to image the tumor located within the torso. The SPECT and CT projections were taken sequentially. The acquired images show that necrotic tumors can de imaged with high resolution to observe liposome inhomogeneous uptake.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114508840","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Development and initial results of a dual-modality SPECT/optical small animal imager 双模SPECT/光学小动物成像仪的开发和初步结果
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596718
J. Peter, H. Ruehle, V. Stamm, R. Schulz, M. Smith, B. Welch, V. Popov, B. Kross, R. Wojcik, A. Weisenberger, S. Majewski, W. Semmler
We have developed a dual-modality single photon (SPECT)/optical (OT) small animal tomographic device to image simultaneously and from identical projection angles in vivo distributions of bioluminescent/(near-infrared) fluorescent and radiolabeled markers. For the SPECT sub-system a compact gamma detector has been developed. A custom-made pinhole (PH) collimator suitable for attachment of reflective surfaces for concurrent optical imaging has been built. The collimator's reflective surfaces filter out optical photons from the multi-energetic photon flux. These photons are directed into a system of mirrors to compose an optical projection that is aligned with the angular field of view of the PH SPECT camera. For the optical detector sub-system a high resolution cooled CCD camera is used. In addition to initial small animal imaging studies several experimental phantom studies were performed with capillary tubes filled with various isotopes and optical markers to evaluate energy/wavelength/tissue dependent spatial resolution capabilities of the sub-systems.
我们开发了一种双模单光子(SPECT)/光学(OT)小动物层析成像装置,以相同的投影角度同时成像生物发光/(近红外)荧光和放射性标记的体内分布。为SPECT分系统研制了一种紧凑的伽马探测器。建立了一种适合于反射面附着的定制针孔准直器,用于并行光学成像。准直器的反射面从多能光子流中滤出光学光子。这些光子被引导到一个镜子系统中,组成一个光学投影,与PH SPECT相机的角度视场对齐。光学探测器子系统采用高分辨率冷却CCD相机。除了最初的小动物成像研究外,还进行了几项实验性模拟研究,用充满各种同位素和光学标记的毛细管进行了模拟研究,以评估子系统的能量/波长/组织依赖的空间分辨率能力。
{"title":"Development and initial results of a dual-modality SPECT/optical small animal imager","authors":"J. Peter, H. Ruehle, V. Stamm, R. Schulz, M. Smith, B. Welch, V. Popov, B. Kross, R. Wojcik, A. Weisenberger, S. Majewski, W. Semmler","doi":"10.1109/NSSMIC.2005.1596718","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596718","url":null,"abstract":"We have developed a dual-modality single photon (SPECT)/optical (OT) small animal tomographic device to image simultaneously and from identical projection angles in vivo distributions of bioluminescent/(near-infrared) fluorescent and radiolabeled markers. For the SPECT sub-system a compact gamma detector has been developed. A custom-made pinhole (PH) collimator suitable for attachment of reflective surfaces for concurrent optical imaging has been built. The collimator's reflective surfaces filter out optical photons from the multi-energetic photon flux. These photons are directed into a system of mirrors to compose an optical projection that is aligned with the angular field of view of the PH SPECT camera. For the optical detector sub-system a high resolution cooled CCD camera is used. In addition to initial small animal imaging studies several experimental phantom studies were performed with capillary tubes filled with various isotopes and optical markers to evaluate energy/wavelength/tissue dependent spatial resolution capabilities of the sub-systems.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"349 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122755366","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Initial performance of the RatCAP, a PET camera for conscious rat brain imaging RatCAP的初步表现,这是一种用于老鼠大脑成像的PET相机
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596971
P. Vaska, C. Woody, D. Schlyer, V. Radeka, P. O'connor, J. Pratte, S. Shokouhi, S. Stoll, S. Junnarkar, M. Purschke, S. Park, S. Southekal, V. Dzhordzhadze, W. Schiffer, J. Neill, M. Murphy, T. Aubele, R. Kristiansen, A. Villanueva, S. Boose, A. Kandasamy, B. Yu, A. Kriplani, S. Krishnamoorthy, R. Lecomte, R. Fontaine
The first fully functional prototype of the RatCAP (Rat conscious animal PET) scanner has been constructed and preliminary evaluations have been performed. RatCAP is a miniature, high performance PET scanner designed specifically to image the brain of a rat while directly attached to its head. The goal is to eliminate the need for anesthesia which can confound quantitative brain studies and prevent simultaneous correlations of neurochemistry and behavior. RatCAP is a fully 3D tomograph with a transaxial (axial) field-of-view of 38(18) mm, outside diameter 72 mm, and weight <200 g which is supported by a small tether. A total of 384 LSO crystals are divided among 12 independent detector blocks, each of which contains an avalanche photodiode (APD) photosensor array and a custom-designed ASIC for highly integrated front-end processing. A custom FPGA-based time-stamp module has been designed and implemented, achieving a preliminary system resolution of 13.9 ns FWHM. With a point source in the FOV center, spatial resolution is 2.1 mm FWHM, energy resolution averages 23% FWHM, and sensitivity is 0.7% at an average threshold of 150 keV. Novel offline data processing algorithms have been developed including methods for time and energy calibrations, corrections for physical effects, and a highly accurate iterative image reconstruction. Initial phantom and rat brain images have been obtained
RatCAP(大鼠意识动物PET)扫描仪的第一个全功能原型已经构建并进行了初步评估。RatCAP是一种微型高性能PET扫描仪,专为直接安装在大鼠头部的大脑成像而设计。目标是消除麻醉的需要,因为麻醉会混淆定量脑研究,并防止神经化学和行为的同时相关性。RatCAP是一种全3D层析成形仪,轴向视野38(18)mm,外径72 mm,重量<200 g,由一根小系绳支撑。总共384个LSO晶体被划分在12个独立的检测器模块中,每个模块包含一个雪崩光电二极管(APD)光敏传感器阵列和一个定制的ASIC,用于高度集成的前端处理。设计并实现了一个基于fpga的定制时间戳模块,初步实现了13.9 ns FWHM的系统分辨率。视场中心有一个点源时,空间分辨率为2.1 mm FWHM,能量分辨率平均为23% FWHM,灵敏度为0.7%,平均阈值为150 keV。新的离线数据处理算法已经开发出来,包括时间和能量校准的方法,物理效应的校正,以及高度精确的迭代图像重建。获得了最初的幻影和大鼠脑图像
{"title":"Initial performance of the RatCAP, a PET camera for conscious rat brain imaging","authors":"P. Vaska, C. Woody, D. Schlyer, V. Radeka, P. O'connor, J. Pratte, S. Shokouhi, S. Stoll, S. Junnarkar, M. Purschke, S. Park, S. Southekal, V. Dzhordzhadze, W. Schiffer, J. Neill, M. Murphy, T. Aubele, R. Kristiansen, A. Villanueva, S. Boose, A. Kandasamy, B. Yu, A. Kriplani, S. Krishnamoorthy, R. Lecomte, R. Fontaine","doi":"10.1109/NSSMIC.2005.1596971","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596971","url":null,"abstract":"The first fully functional prototype of the RatCAP (Rat conscious animal PET) scanner has been constructed and preliminary evaluations have been performed. RatCAP is a miniature, high performance PET scanner designed specifically to image the brain of a rat while directly attached to its head. The goal is to eliminate the need for anesthesia which can confound quantitative brain studies and prevent simultaneous correlations of neurochemistry and behavior. RatCAP is a fully 3D tomograph with a transaxial (axial) field-of-view of 38(18) mm, outside diameter 72 mm, and weight <200 g which is supported by a small tether. A total of 384 LSO crystals are divided among 12 independent detector blocks, each of which contains an avalanche photodiode (APD) photosensor array and a custom-designed ASIC for highly integrated front-end processing. A custom FPGA-based time-stamp module has been designed and implemented, achieving a preliminary system resolution of 13.9 ns FWHM. With a point source in the FOV center, spatial resolution is 2.1 mm FWHM, energy resolution averages 23% FWHM, and sensitivity is 0.7% at an average threshold of 150 keV. Novel offline data processing algorithms have been developed including methods for time and energy calibrations, corrections for physical effects, and a highly accurate iterative image reconstruction. Initial phantom and rat brain images have been obtained","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117223209","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Development of silica aerogel with any density 任意密度二氧化硅气凝胶的研制
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596380
M. Tabata, I. Adachi, T. Fukushima, H. Kawai, H. Kishimoto, A. Kuratani, H. Nakayama, S. Nishida, T. Noguchi, K. Okudaira, Y. Tajima, H. Yano, H. Yokogawa, H. Yoshida
New production methods of silica aerogel with high and low refractive indices have been developed. A very slow shrinkage of alcogel at room temperature has made possible producing aerogel with high refractive indices of up to 1.265 without cracks. Even higher refractive indices than 1.08, the transmission length of the aerogel obtained from this technique has been measured to be about 10 to 20 mm at 400 nm wave length. A mold made of alcogel which endures shrinkage in the supercritical drying process has provided aerogel with the extremely low density of 0.009 g/cm3, which corresponds to the refractive index of 1.002. We have succeeded producing aerogel with a wide range of densities
开发了高折射率和低折射率二氧化硅气凝胶的新生产方法。酒精凝胶在室温下非常缓慢的收缩使得生产具有高达1.265的高折射率的无裂纹气凝胶成为可能。折射率高于1.08的气凝胶在400 nm波长下的透射长度约为10 ~ 20 mm。一种由酒精凝胶制成的模具,在超临界干燥过程中经受收缩,提供的气凝胶密度极低,为0.009 g/cm3,对应的折射率为1.002。我们已经成功地生产了密度范围很广的气凝胶
{"title":"Development of silica aerogel with any density","authors":"M. Tabata, I. Adachi, T. Fukushima, H. Kawai, H. Kishimoto, A. Kuratani, H. Nakayama, S. Nishida, T. Noguchi, K. Okudaira, Y. Tajima, H. Yano, H. Yokogawa, H. Yoshida","doi":"10.1109/NSSMIC.2005.1596380","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596380","url":null,"abstract":"New production methods of silica aerogel with high and low refractive indices have been developed. A very slow shrinkage of alcogel at room temperature has made possible producing aerogel with high refractive indices of up to 1.265 without cracks. Even higher refractive indices than 1.08, the transmission length of the aerogel obtained from this technique has been measured to be about 10 to 20 mm at 400 nm wave length. A mold made of alcogel which endures shrinkage in the supercritical drying process has provided aerogel with the extremely low density of 0.009 g/cm3, which corresponds to the refractive index of 1.002. We have succeeded producing aerogel with a wide range of densities","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"113 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132818661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Implementation of scatter corrected list-mode OP-EM reconstruction algorithm and a dual (histogram/list-mode) reconstruction scheme for dynamic PET imaging 实现散射校正列表模式的OP-EM重建算法和动态PET成像的双重(直方图/列表模式)重建方案
Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596792
J. Cheng, A. Rahmim, S. Blinder, M. Camborde, V. Sossi
We describe an implementation of ordinary Poisson list-mode expectation maximization (OP-LMEM) algorithm for the high resolution research tomography (HRRT) with a scatter correction method based on the single scatter simulation (SSS) technique, and a random correction method based on the variance-reduced delayed-coincidence technique. A hybrid EM algorithm has also been implemented in list-mode reconstruction (H-LMEM) using delayed-coincidence event subtraction technique with the same scatter correction as in OP-LMEM. The reconstructed images of a dynamic scanning sequence of a contrast phantom have been compared with those reconstructed using the histogram-mode reconstruction, in particular, 3D ordinary Poisson ordered subset expectation maximization (3D-OP) with the same variance-reduced random and estimated scatter. The transaxial and axial profile analyses have shown excellent agreement between histogram and both list-mode reconstructions. Likewise the preliminary contrast and noise analyses have shown a close agreement between histogram-mode and both list-mode reconstructions. Based on these results, a dual reconstruction scheme can now be applied to dynamic imaging in positron emission tomography (PET) with scatter correction; i.e. histogram-mode reconstruction (3D-OP) can be applied to frames with a large number of counts, and list-mode reconstruction (OP-LMEM) will subsequently be used for low statistics frames, as an effort to obtain efficient and quantitatively accurate reconstructions applicable to state-of-the-art dynamic PET imaging using the HRRT.
利用基于单散射模拟(SSS)技术的散点校正方法和基于方差减少延迟重合技术的随机校正方法实现了高分辨率研究层析成像(HRRT)的普通泊松列表模式期望最大化(OP-LMEM)算法。在列表模式重建(H-LMEM)中也实现了一种混合EM算法,该算法使用延迟符合事件减法技术,散点校正与OP-LMEM相同。将对比幻影动态扫描序列的重建图像与直方图模式重建图像进行了比较,特别是具有相同方差减少随机和估计散点的三维普通泊松有序子集期望最大化(3D- op)重建图像。跨轴和轴向剖面分析显示直方图和两种列表模式重建之间具有良好的一致性。同样,初步的对比和噪声分析表明直方图模式和列表模式重建之间的密切一致。基于这些结果,双重重建方案现在可以应用于散射校正的正电子发射断层扫描(PET)的动态成像;即直方图模式重建(3D-OP)可以应用于具有大量计数的帧,列表模式重建(OP-LMEM)随后将用于低统计帧,以获得适用于使用HRRT的最先进的动态PET成像的高效和定量准确的重建。
{"title":"Implementation of scatter corrected list-mode OP-EM reconstruction algorithm and a dual (histogram/list-mode) reconstruction scheme for dynamic PET imaging","authors":"J. Cheng, A. Rahmim, S. Blinder, M. Camborde, V. Sossi","doi":"10.1109/NSSMIC.2005.1596792","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596792","url":null,"abstract":"We describe an implementation of ordinary Poisson list-mode expectation maximization (OP-LMEM) algorithm for the high resolution research tomography (HRRT) with a scatter correction method based on the single scatter simulation (SSS) technique, and a random correction method based on the variance-reduced delayed-coincidence technique. A hybrid EM algorithm has also been implemented in list-mode reconstruction (H-LMEM) using delayed-coincidence event subtraction technique with the same scatter correction as in OP-LMEM. The reconstructed images of a dynamic scanning sequence of a contrast phantom have been compared with those reconstructed using the histogram-mode reconstruction, in particular, 3D ordinary Poisson ordered subset expectation maximization (3D-OP) with the same variance-reduced random and estimated scatter. The transaxial and axial profile analyses have shown excellent agreement between histogram and both list-mode reconstructions. Likewise the preliminary contrast and noise analyses have shown a close agreement between histogram-mode and both list-mode reconstructions. Based on these results, a dual reconstruction scheme can now be applied to dynamic imaging in positron emission tomography (PET) with scatter correction; i.e. histogram-mode reconstruction (3D-OP) can be applied to frames with a large number of counts, and list-mode reconstruction (OP-LMEM) will subsequently be used for low statistics frames, as an effort to obtain efficient and quantitatively accurate reconstructions applicable to state-of-the-art dynamic PET imaging using the HRRT.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123069678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
期刊
IEEE Nuclear Science Symposium Conference Record, 2005
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1