首页 > 最新文献

Deutsche zahnarztliche Zeitschrift最新文献

英文 中文
[Fixed tooth replacement of milled/spark eroded titanium]. 【磨铣/火花侵蚀钛的固定齿更换】。
Pub Date : 1991-11-01
P D Reppel, K Böning, M Walter

In a clinical study the accuracy of fit of 82 crowns manufactured with the Procera-system (duplication milling/spark erosion) was investigated. The average marginal space width was 71 microns. Roughness of eroded surfaces was found to be similar to that of coarsely ground metal. Below the eroded areas a zone of increased hardness with a width of approximately 20 microns was demonstrated.

在一项临床研究中,研究了82个用procera系统制作的冠(重复铣削/火花侵蚀)的配合精度。平均边际空间宽度为71微米。发现侵蚀表面的粗糙度与粗磨金属的粗糙度相似。在侵蚀区下方,出现了硬度增加的区域,宽度约为20微米。
{"title":"[Fixed tooth replacement of milled/spark eroded titanium].","authors":"P D Reppel,&nbsp;K Böning,&nbsp;M Walter","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In a clinical study the accuracy of fit of 82 crowns manufactured with the Procera-system (duplication milling/spark erosion) was investigated. The average marginal space width was 71 microns. Roughness of eroded surfaces was found to be similar to that of coarsely ground metal. Below the eroded areas a zone of increased hardness with a width of approximately 20 microns was demonstrated.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"756-8"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12980795","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Interocclusal clearance and changes in occlusal position in dentate and edentulous jaws. 1]. 有齿颌和无齿颌的咬合间隙和咬合位置的变化。1]。
Pub Date : 1991-11-01
R W Ott

Six methods of assessing the resting position were evaluated in this study of 22 patients with teeth and 10 edentulous patients. None of these methods yielded reproducible results. The resting position is not a fixed, constant value, but depends on the method used. As could be shown by means of the standard deviation the method used to determine the resting position has a considerable influence on the distribution, and hence on the margin of error when the vertical relation is being determined. Small ranges of distribution were achieved: a) by means of the closest speaking distance when the patient spoke the numbers from 60 to 70 in a natural voice, b) after prompt relaxation of the lower jaw when the patients were asked to relax their jaws, c) when the interocclusal distance was measured after the mouth had been opened a little and the lips subsequently touched again lightly. Since there is little difference in the values with any one patient the three methods can be recommended for practical use.

本研究对22例有牙患者和10例无牙患者进行了六种静息位评估方法。这些方法都没有得到可重复的结果。静止位置不是一个固定不变的值,而是取决于所使用的方法。从标准偏差可以看出,用于确定静息位置的方法对分布有相当大的影响,因此在确定垂直关系时对误差范围也有相当大的影响。小范围的分布是:a)当患者以自然的声音说出60到70的数字时,通过最近的说话距离,b)当患者被要求放松下颌时,通过迅速放松下颌,c)当嘴巴稍微张开后,嘴唇再次轻触时测量咬合距离。由于任何一个病人的数值差异不大,因此可以推荐三种方法用于实际应用。
{"title":"[Interocclusal clearance and changes in occlusal position in dentate and edentulous jaws. 1].","authors":"R W Ott","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Six methods of assessing the resting position were evaluated in this study of 22 patients with teeth and 10 edentulous patients. None of these methods yielded reproducible results. The resting position is not a fixed, constant value, but depends on the method used. As could be shown by means of the standard deviation the method used to determine the resting position has a considerable influence on the distribution, and hence on the margin of error when the vertical relation is being determined. Small ranges of distribution were achieved: a) by means of the closest speaking distance when the patient spoke the numbers from 60 to 70 in a natural voice, b) after prompt relaxation of the lower jaw when the patients were asked to relax their jaws, c) when the interocclusal distance was measured after the mouth had been opened a little and the lips subsequently touched again lightly. Since there is little difference in the values with any one patient the three methods can be recommended for practical use.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"762-5"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12980797","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Chewing force discrimination in a biofeedback experiment]. [生物反馈实验中的咀嚼力判别]。
Pub Date : 1991-11-01
H Jakstat

Chewing forces were measured in a needle point tracing while the patients could view their actual and the proposed chewing forces (5 N, 10 N and 30 N) on a computer screen (biofeedback). Most probands used less than the proposed forces in the experiments. All probands approached the proposed level of force step by step. Fatigue of the chewing muscles led to a change in the Fourier-transformation of the recorded samples: An increase in short-waved components (frequencies of approximately 1 Hz) was found.

通过针尖追踪法测量咀嚼力,同时患者可以在计算机屏幕上查看实际咀嚼力和建议咀嚼力(5 N, 10 N和30 N)(生物反馈)。大多数先证者在实验中使用的力小于建议的力。所有先证者逐步接近建议的武力水平。咀嚼肌肉的疲劳导致记录样品的傅里叶变换发生变化:发现短波成分(频率约为1 Hz)增加。
{"title":"[Chewing force discrimination in a biofeedback experiment].","authors":"H Jakstat","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Chewing forces were measured in a needle point tracing while the patients could view their actual and the proposed chewing forces (5 N, 10 N and 30 N) on a computer screen (biofeedback). Most probands used less than the proposed forces in the experiments. All probands approached the proposed level of force step by step. Fatigue of the chewing muscles led to a change in the Fourier-transformation of the recorded samples: An increase in short-waved components (frequencies of approximately 1 Hz) was found.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"766-8"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12980798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Suitability of various materials for indexing needle point registrations]. [各种材料标度针点配准的适用性]。
Pub Date : 1991-11-01
A Genieser, H Jakstat

Acrylic, plaster and polyether were evaluated for their accuracy in indexing needle point registration. Additionally, a new experimental system was tested, that permits the dentist do immediately verify the accuracy of the recording. Best results were obtained when the indexes were not removed from the occlusal plane plates. When the indexes were dislodged, acrylic and plaster demonstrated the most accurate results in repositioning the occlusal plane plates. The experimental system demonstrated comparable accuracy to both, acrylic and plaster.

评价了丙烯酸、石膏和聚醚在分度针尖对准中的准确性。此外,还测试了一种新的实验系统,使牙医能够立即验证记录的准确性。当指标不从咬合平面板上移除时,效果最好。当指标移位时,丙烯酸树脂和石膏在重新定位咬合平面板时显示出最准确的结果。实验系统证明了相当的准确性,丙烯酸和石膏。
{"title":"[Suitability of various materials for indexing needle point registrations].","authors":"A Genieser,&nbsp;H Jakstat","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Acrylic, plaster and polyether were evaluated for their accuracy in indexing needle point registration. Additionally, a new experimental system was tested, that permits the dentist do immediately verify the accuracy of the recording. Best results were obtained when the indexes were not removed from the occlusal plane plates. When the indexes were dislodged, acrylic and plaster demonstrated the most accurate results in repositioning the occlusal plane plates. The experimental system demonstrated comparable accuracy to both, acrylic and plaster.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"769-71"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12980799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Castability and accuracy of fit of a titanium casting system]. 钛铸造系统的浇注性能和配合精度。
Pub Date : 1991-11-01
E Klinger, K Böning, M Walter

The titanium casting system Cyclarc (Morita) was examined for its suitability for the fabrication of dense, fitting restorations. The investment material Titavest CB exhibited no setting expansion. Instead, thermal expansion, highly dependent on the liquid/power ratio and the temperature during preheating, was observed. The castability of unalloyed titanium is fully acceptable for the fabrication of prosthetic restorations. Single crowns showed a high accuracy of fit, if an optimal liquid/power ratio was used for investment.

钛铸造系统Cyclarc(森田)被检查其适合制造密集,适合修复。投资材料tiavest CB无凝固膨胀。相反,观察到热膨胀,高度依赖于液体/功率比和预热期间的温度。非合金化钛的铸造性是完全可以接受的假体修复的制造。如果使用最佳的液体/功率比进行投资,则单个冠的拟合精度较高。
{"title":"[Castability and accuracy of fit of a titanium casting system].","authors":"E Klinger,&nbsp;K Böning,&nbsp;M Walter","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The titanium casting system Cyclarc (Morita) was examined for its suitability for the fabrication of dense, fitting restorations. The investment material Titavest CB exhibited no setting expansion. Instead, thermal expansion, highly dependent on the liquid/power ratio and the temperature during preheating, was observed. The castability of unalloyed titanium is fully acceptable for the fabrication of prosthetic restorations. Single crowns showed a high accuracy of fit, if an optimal liquid/power ratio was used for investment.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"743-5"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12980791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Difference reflectometry might permit process control for dental laser applications]. [差反射法可能允许对牙科激光应用进行过程控制]。
Pub Date : 1991-11-01
W H Raab, S M Rosiwal, K Reithmayer, H W Bergmann

Difference reflectometry is a new method for assessing material surfaces by measuring the relative amount of light reflected within a range of 300-720 nm. The in vivo and in vitro results of the present study indicate that it is possible to transfer this measuring principle to dental applications. Reflexion measurements allow the detection of hard tooth structures and their pathologic alterations with adequate exactness. With the aid of this method it is possible to differentiate between carious hard tissues and clinically healthy tissues by color and surface structure during excavation. It also allows a reliable demarcation from oral soft tissues. Due to its high measuring frequency it may be used as on-line process control. In contrast to other spectrometric methods it requires a minimum of equipment and is easy to handle.

差分反射法是一种通过测量在300-720 nm范围内的相对反射光量来评估材料表面的新方法。本研究的体内和体外结果表明,可以将这种测量原理转移到牙科应用中。反射测量允许检测硬牙结构及其病理变化具有足够的准确性。借助该方法,可以通过挖掘时的颜色和表面结构来区分龋齿硬组织和临床健康组织。它还可以可靠地区分口腔软组织。由于测量频率高,可用于在线过程控制。与其他光谱测定方法相比,它需要最少的设备,易于操作。
{"title":"[Difference reflectometry might permit process control for dental laser applications].","authors":"W H Raab,&nbsp;S M Rosiwal,&nbsp;K Reithmayer,&nbsp;H W Bergmann","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Difference reflectometry is a new method for assessing material surfaces by measuring the relative amount of light reflected within a range of 300-720 nm. The in vivo and in vitro results of the present study indicate that it is possible to transfer this measuring principle to dental applications. Reflexion measurements allow the detection of hard tooth structures and their pathologic alterations with adequate exactness. With the aid of this method it is possible to differentiate between carious hard tissues and clinically healthy tissues by color and surface structure during excavation. It also allows a reliable demarcation from oral soft tissues. Due to its high measuring frequency it may be used as on-line process control. In contrast to other spectrometric methods it requires a minimum of equipment and is easy to handle.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"729-33"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12979420","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Non-invasive method of measuring dentin resistance to the limit of the preparation depth]. 【无创测量牙本质阻力至预备深度极限的方法】。
Pub Date : 1991-11-01
M Gente, H J Wenz

Electrical resistance measurements may be used to determine the situation of the pulp horn tips of teeth prepared for crown restorations. The resistance value recorded for these sites of minimum dentin thickness depends on the thickness of the dentin layer and the degree of tooth development. A resistance value of 25 k omega revealed dentin thickness of 0.7-1.45 mm. The teeth of younger patients had thicker dentin layers than those of older patients.

电阻测量可用于确定牙冠修复准备的牙髓角尖的情况。这些最小牙本质厚度的位置所记录的电阻值取决于牙本质层的厚度和牙齿发育的程度。当电阻值为25 k ω时,牙本质厚度为0.7-1.45 mm。年轻患者的牙本质层较老年患者厚。
{"title":"[Non-invasive method of measuring dentin resistance to the limit of the preparation depth].","authors":"M Gente,&nbsp;H J Wenz","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Electrical resistance measurements may be used to determine the situation of the pulp horn tips of teeth prepared for crown restorations. The resistance value recorded for these sites of minimum dentin thickness depends on the thickness of the dentin layer and the degree of tooth development. A resistance value of 25 k omega revealed dentin thickness of 0.7-1.45 mm. The teeth of younger patients had thicker dentin layers than those of older patients.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"771-3"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12979912","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Long-term success of various implant types--a study over 15 years]. [各种种植体类型的长期成功——一项超过15年的研究]。
Pub Date : 1991-10-01
M Heners, W Walther, M Wörle

This study reports the clinical success rates of 6 different implant types inserted with defined clinical indications. The criterium used was implant loss. The survival periods of a total of 1723 implants were statistically evaluated according to Kaplan and Meier's method in relation to the type of implant used and the indication chosen.

本研究报告了6种不同种植体类型的临床成功率。使用的标准是种植体丢失。根据Kaplan和Meier的方法,统计1723个种植体的生存期与所使用的种植体类型和所选择的适应证的关系。
{"title":"[Long-term success of various implant types--a study over 15 years].","authors":"M Heners,&nbsp;W Walther,&nbsp;M Wörle","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This study reports the clinical success rates of 6 different implant types inserted with defined clinical indications. The criterium used was implant loss. The survival periods of a total of 1723 implants were statistically evaluated according to Kaplan and Meier's method in relation to the type of implant used and the indication chosen.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 10","pages":"672-5"},"PeriodicalIF":0.0,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12979480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[The attachments of the IMZ system in full denture prosthodontics]. [IMZ系统在全口义齿修复中的附着体]。
Pub Date : 1991-10-01
B Wöstmann, K R Rasch, H van Benthem

With the aid of a photoelastic model it was possible to visualize the transmission of forces from four different types of attachment (parallel bar, round bar, RS- and O-ring attachment) onto IMZ implants. The parallel bar produced the highest stresses between the implants. By contrast, the round bar mainly transmitted transverse forces. RS- and O-ring attachments transmitted the least forces onto the implants. The retentive power of the attachments has also been measured. The round bar proved to be almost twice as retentive as the RS attachment and nearly three times as retentive as the O-ring.

借助光弹性模型,可以可视化四种不同类型的附着物(平行杆、圆杆、RS和o形环附着物)在IMZ植入物上的力传递。平行杆在植入物之间产生最大的应力。相比之下,圆杆主要传递横向力。RS型和o型环附着体传递给植入物的力最小。还测量了附件的保持力。事实证明,圆杆的保持力几乎是RS附件的两倍,几乎是o型圈的三倍。
{"title":"[The attachments of the IMZ system in full denture prosthodontics].","authors":"B Wöstmann,&nbsp;K R Rasch,&nbsp;H van Benthem","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>With the aid of a photoelastic model it was possible to visualize the transmission of forces from four different types of attachment (parallel bar, round bar, RS- and O-ring attachment) onto IMZ implants. The parallel bar produced the highest stresses between the implants. By contrast, the round bar mainly transmitted transverse forces. RS- and O-ring attachments transmitted the least forces onto the implants. The retentive power of the attachments has also been measured. The round bar proved to be almost twice as retentive as the RS attachment and nearly three times as retentive as the O-ring.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 10","pages":"682-5"},"PeriodicalIF":0.0,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12979483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[The effect of bedding type on implant and abutment tooth in tooth/implant-supported bridgework]. [牙/种植体支撑桥中垫层类型对种植体和基牙的影响]。
Pub Date : 1991-10-01
A Krämer, H Weber

17 distal extension cases were treated with IMZ implants supporting a fixed-removable bridge connected to a natural tooth abutment with a precision attachment. Instead of the polyoxmethylene internal shock absorber an identically dimensioned titanium element was incorporated in the implants of every second patient. Patients were monitored on a recall schedule. Implant and tooth mobility, pocket probing depth, and bone loss were the parameters evaluated. The results after a mean incorporation time of 16.5 months indicate that, at least during this initial time of function, there are no differences between a mobile and rigid bedding of the superstructure on the implants.

17例远端伸展病例采用IMZ种植体治疗,IMZ种植体支持固定-可移动桥连接到具有精密附着物的天然牙基牙。代替聚氧亚甲基内部减震器,一个相同尺寸的钛元素被纳入植入物的每两个病人。病人按照召回计划进行监测。评估种植体和牙齿的活动度、口袋探测深度和骨质流失。平均掺入时间为16.5个月后的结果表明,至少在初始功能时间内,植入体上部结构的移动层和刚性层之间没有差异。
{"title":"[The effect of bedding type on implant and abutment tooth in tooth/implant-supported bridgework].","authors":"A Krämer,&nbsp;H Weber","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>17 distal extension cases were treated with IMZ implants supporting a fixed-removable bridge connected to a natural tooth abutment with a precision attachment. Instead of the polyoxmethylene internal shock absorber an identically dimensioned titanium element was incorporated in the implants of every second patient. Patients were monitored on a recall schedule. Implant and tooth mobility, pocket probing depth, and bone loss were the parameters evaluated. The results after a mean incorporation time of 16.5 months indicate that, at least during this initial time of function, there are no differences between a mobile and rigid bedding of the superstructure on the implants.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 10","pages":"686-8"},"PeriodicalIF":0.0,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12979484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Deutsche zahnarztliche Zeitschrift
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1