Space Charge Evolution in XLPE with Long-term Aging under DC Voltage - the Effect of Temperature and Polarity Reversals 直流电压下长期老化XLPE的空间电荷演化——温度和极性反转的影响
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311988
M. Abou-Dakka, A. Bulinski, S. Bamji
DC field long-term breakdown characteristics of commercially available cable-grade cross-linked polyethylene (XLPE) and tree retardant XLPE (TR-XLPE) were investigated. At room temperature, under a unipolar field of 50 kV/mm, more than 90% of XLPE specimens survived 52, 000 h (~6 yrs) of aging, whereas all TR-XLPE specimens broke down within less than 1, 200 h. Reversing the polarity increased the life-time of TR-XLPE by more than 20 times but reduced significantly the life-time of the XLPE specimens. At 75 degC and with polarity reversals both materials survived almost 21, 000 h without any breakdown. These results are discussed in terms of the space charge accumulation and retention properties of the two materials with emphasis on the role of additives in determining insulation properties under DC fields.
研究了市售电缆级交联聚乙烯(XLPE)和树阻交联聚乙烯(TR-XLPE)直流场长期击穿特性。在室温条件下,在50 kV/mm的单极电场下,90%以上的XLPE试样在52,000 h(~6年)的老化时间内存活,而所有TR-XLPE试样在不到1,200 h的时间内都发生了破坏。扭转极性使TR-XLPE试样的寿命增加了20倍以上,但显著降低了XLPE试样的寿命。在75度和极性反转的情况下,两种材料都能存活近21000小时而没有任何故障。讨论了这两种材料的空间电荷积累和保留特性,重点讨论了添加剂在直流电场下决定绝缘性能的作用。
{"title":"Space Charge Evolution in XLPE with Long-term Aging under DC Voltage - the Effect of Temperature and Polarity Reversals","authors":"M. Abou-Dakka, A. Bulinski, S. Bamji","doi":"10.1109/CEIDP.2006.311988","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311988","url":null,"abstract":"DC field long-term breakdown characteristics of commercially available cable-grade cross-linked polyethylene (XLPE) and tree retardant XLPE (TR-XLPE) were investigated. At room temperature, under a unipolar field of 50 kV/mm, more than 90% of XLPE specimens survived 52, 000 h (~6 yrs) of aging, whereas all TR-XLPE specimens broke down within less than 1, 200 h. Reversing the polarity increased the life-time of TR-XLPE by more than 20 times but reduced significantly the life-time of the XLPE specimens. At 75 degC and with polarity reversals both materials survived almost 21, 000 h without any breakdown. These results are discussed in terms of the space charge accumulation and retention properties of the two materials with emphasis on the role of additives in determining insulation properties under DC fields.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"80 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116257903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Corona Ring Design of ±800kV DC Composite Insulator Based on Computer Analysis 基于计算机分析的±800kV直流复合绝缘子电晕环设计
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311968
W. Sima, Kun Wu, Qing Yang, Caixin Sun
This paper presents a 3D electric-field calculation model of the plusmn800 kV DC transmission line composite insulators based on finite element method. With this 3D model, this paper introduces the effect of the tower, transmission lines and the parameters of the corona rings on the potential and e-field distribution along the composite insulators, and optimizes the corona ring design in order to control the maximum e-field along the insulator surface and corona ring surface.
本文提出了基于有限元法的plusmn800 kV直流输电线路复合绝缘子三维电场计算模型。利用该三维模型,介绍了电晕环、输电线路和电晕环参数对复合绝缘子电位分布和电场分布的影响,优化了电晕环的设计,以控制复合绝缘子表面和电晕环表面的最大电场。
{"title":"Corona Ring Design of ±800kV DC Composite Insulator Based on Computer Analysis","authors":"W. Sima, Kun Wu, Qing Yang, Caixin Sun","doi":"10.1109/CEIDP.2006.311968","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311968","url":null,"abstract":"This paper presents a 3D electric-field calculation model of the plusmn800 kV DC transmission line composite insulators based on finite element method. With this 3D model, this paper introduces the effect of the tower, transmission lines and the parameters of the corona rings on the potential and e-field distribution along the composite insulators, and optimizes the corona ring design in order to control the maximum e-field along the insulator surface and corona ring surface.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127882579","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Change in Electroluminescence Activity in Polymers Prior to AC Dielectric Breakdown 交流介质击穿前聚合物电致发光活性的变化
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312083
D. Mary, D. Malec
The electroluminescence activity of different polymers (LDPE, PI, PET, PP and PEN) has been investigated from low to high AC 50 Hz electric fields. Experiments have been focused on the evolution of the electroluminescence intensity versus applied voltage. Three different electroluminescence regimes have been distinguished for both studied polymers.
研究了不同聚合物(LDPE、PI、PET、PP和PEN)在低至高交流50hz电场下的电致发光活性。实验的重点是电致发光强度随外加电压的变化。三种不同的电致发光机制已被区分为研究聚合物。
{"title":"Change in Electroluminescence Activity in Polymers Prior to AC Dielectric Breakdown","authors":"D. Mary, D. Malec","doi":"10.1109/CEIDP.2006.312083","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312083","url":null,"abstract":"The electroluminescence activity of different polymers (LDPE, PI, PET, PP and PEN) has been investigated from low to high AC 50 Hz electric fields. Experiments have been focused on the evolution of the electroluminescence intensity versus applied voltage. Three different electroluminescence regimes have been distinguished for both studied polymers.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128042660","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Towards water-resistant high voltage insulation systems: An ageing study of a technological water-blocking polymer 迈向防水高压绝缘系统:技术阻水聚合物的老化研究
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311982
L. L. Barré, Alun Vaughan, Simon Sutton
This paper examines the solid state ageing characteristics of a technological water-blocking system, based upon the polysaccharide guar, a material used in lightweight power cable designs as a water tree inhibiting system. Through a combination of viscometry and Raman spectroscopy, we show that ageing primarily affects the polymer backbone, which is not associated with guar/water interactions. We conclude that guar binds strongly with water and that this is not affected significantly by ageing. Guar therefore constitutes an attractive means of protecting high voltage insulation systems from exposure to water, so reducing the likelihood of water treeing, even following many years of ageing.
本文研究了一种以瓜尔胶为基础的技术阻水系统的固态老化特性,瓜尔胶是一种用于轻型电力电缆设计的水树抑制系统。通过粘度学和拉曼光谱的结合,我们发现老化主要影响聚合物骨架,而这与瓜尔胶/水的相互作用无关。我们得出的结论是瓜尔胶与水的结合力很强,这不会受到年龄的显著影响。瓜尔胶因此构成了一种有吸引力的保护高压绝缘系统免受水的手段,从而减少了水树的可能性,即使经过多年的老化。
{"title":"Towards water-resistant high voltage insulation systems: An ageing study of a technological water-blocking polymer","authors":"L. L. Barré, Alun Vaughan, Simon Sutton","doi":"10.1109/CEIDP.2006.311982","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311982","url":null,"abstract":"This paper examines the solid state ageing characteristics of a technological water-blocking system, based upon the polysaccharide guar, a material used in lightweight power cable designs as a water tree inhibiting system. Through a combination of viscometry and Raman spectroscopy, we show that ageing primarily affects the polymer backbone, which is not associated with guar/water interactions. We conclude that guar binds strongly with water and that this is not affected significantly by ageing. Guar therefore constitutes an attractive means of protecting high voltage insulation systems from exposure to water, so reducing the likelihood of water treeing, even following many years of ageing.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122000217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effects of X-Ray Radiation on Solid Insulating Materials x射线辐射对固体绝缘材料的影响
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311976
S. Sudalaimuthu, M. Thomas, S. Senthil Kumar, V. Vinod Kumar
In the present work an attempt has been made to study the effects of ionizing radiation such as X-ray irradiation on the electrical properties of solid insulating materials such as FR4 laminates and relate these to concurrent changes in the physical and chemical properties of the above material. FR4 laminates find extensive use as an insulating material in PCB's where HV power supply components are mounted in X-ray generators. In the present work samples of FR4 laminates were irradiated in ambient air with X-rays to different absorbed doses of up to 6.3 times 104 rad. The post irradiation effects on the material shows deterioration in electrical properties such as dielectric strength, dissipation factor, volume resistivity and surface resistivity. Analysis by FTIR indicates that when samples are irradiated in air, it exhibits increase of hydroxyl groups and decrease of all the characteristic infrared bands of the initial chemical functions. SEM photographs show newer defects generated in the irradiated sample. There is also a change in color of the material when exposed to X-rays and this is due to the fact that X-ray initiated free charge gets trapped by the defects/impurities and changes the absorption characteristic of the material. In addition, the decrease in crystallinity and increase in surface roughness was monitored by Differential Scanning Calorimetry and contact type profilometer.
在目前的工作中,试图研究电离辐射(如x射线辐照)对固体绝缘材料(如FR4层叠板)电学性能的影响,并将这些影响与上述材料的物理和化学性能的同步变化联系起来。FR4层压板广泛用作PCB中的绝缘材料,其中高压电源组件安装在x射线发生器中。在本工作中,FR4层压板样品在环境空气中以高达6.3倍104 rad的不同吸收剂量进行x射线辐照,辐照后对材料的电学性能(介电强度、耗散系数、体积电阻率和表面电阻率)产生了影响。FTIR分析表明,样品在空气中辐照后,羟基增加,初始化学功能的所有特征红外波段都降低。扫描电镜照片显示在辐照样品中产生了新的缺陷。当暴露在x射线下时,材料的颜色也会发生变化,这是由于x射线引发的自由电荷被缺陷/杂质捕获并改变了材料的吸收特性。此外,用差示扫描量热仪和接触式轮廓仪监测了结晶度的下降和表面粗糙度的增加。
{"title":"Effects of X-Ray Radiation on Solid Insulating Materials","authors":"S. Sudalaimuthu, M. Thomas, S. Senthil Kumar, V. Vinod Kumar","doi":"10.1109/CEIDP.2006.311976","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311976","url":null,"abstract":"In the present work an attempt has been made to study the effects of ionizing radiation such as X-ray irradiation on the electrical properties of solid insulating materials such as FR4 laminates and relate these to concurrent changes in the physical and chemical properties of the above material. FR4 laminates find extensive use as an insulating material in PCB's where HV power supply components are mounted in X-ray generators. In the present work samples of FR4 laminates were irradiated in ambient air with X-rays to different absorbed doses of up to 6.3 times 104 rad. The post irradiation effects on the material shows deterioration in electrical properties such as dielectric strength, dissipation factor, volume resistivity and surface resistivity. Analysis by FTIR indicates that when samples are irradiated in air, it exhibits increase of hydroxyl groups and decrease of all the characteristic infrared bands of the initial chemical functions. SEM photographs show newer defects generated in the irradiated sample. There is also a change in color of the material when exposed to X-rays and this is due to the fact that X-ray initiated free charge gets trapped by the defects/impurities and changes the absorption characteristic of the material. In addition, the decrease in crystallinity and increase in surface roughness was monitored by Differential Scanning Calorimetry and contact type profilometer.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131384094","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Impulsive strength of power cables with different XLPE compounds 不同交联聚乙烯复合材料电力电缆的脉冲强度
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312104
M. Marzinotto, C. Mazzetti, M. Pompili, P. Schiaffino
Standard lightning impulsive dielectric strength tests were performed on cable model samples manufactured with the same technology and the same materials used for high voltage cable application. In particular four different commercial XLPE compounds are considered. Tests were carried out with the aim to investigate the impulsive strength behaviour at room and 90 degC of the compounds when they are subjected to both positive and negative testing wave polarities. The results have been compared in terms of Weibull scale and shape parameters.
采用相同的技术和相同的材料制造的电缆模型样品进行了标准的雷电脉冲介电强度试验。特别考虑了四种不同的商用交联聚乙烯化合物。测试进行的目的是调查脉冲强度的行为,在房间和90度的化合物,当他们受到正和负测试波极性。用威布尔尺度和形状参数对结果进行了比较。
{"title":"Impulsive strength of power cables with different XLPE compounds","authors":"M. Marzinotto, C. Mazzetti, M. Pompili, P. Schiaffino","doi":"10.1109/CEIDP.2006.312104","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312104","url":null,"abstract":"Standard lightning impulsive dielectric strength tests were performed on cable model samples manufactured with the same technology and the same materials used for high voltage cable application. In particular four different commercial XLPE compounds are considered. Tests were carried out with the aim to investigate the impulsive strength behaviour at room and 90 degC of the compounds when they are subjected to both positive and negative testing wave polarities. The results have been compared in terms of Weibull scale and shape parameters.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134187837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
An Experimental Evaluation on Ozone Generation by Local Discharge Type Gas Jets 局部放电式气体射流产生臭氧的实验评价
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312090
T. Shirotsuka, R. Ohyama
A new type ozone generator with local dielectric barrier discharges operated in very thin gas jets has been experimentally investigated for evaluating an efficient generation process of the ozonic atmosphere. The use of gas jets is to improve an enhancement of the barrier discharges and a cooling effect on the efficiency. The experiments have been conducted to characterize the ozone generation process under following variable parameters: inputted discharge power from a high-voltage source, flow rate of the injected gas jets, and discharge electrode arrangements for optimizing the efficiency. In this paper, a fundamental design of the ozone generator and some quantitative results are presented. The experimentally obtained evaluation indicates an effective performance for the efficiency in a lower range of discharge power.
为了评价臭氧大气的有效生成过程,对一种在极薄气体射流中进行局部介质阻挡放电的新型臭氧发生器进行了实验研究。气体射流的使用是为了提高屏障放电的增强和对效率的冷却效果。在高压源输入的放电功率、喷射气体的流量和优化效率的放电电极布置等参数下,对臭氧生成过程进行了表征。本文介绍了臭氧发生器的基本设计和一些定量结果。实验结果表明,在较低的放电功率范围内,该方法的效率是有效的。
{"title":"An Experimental Evaluation on Ozone Generation by Local Discharge Type Gas Jets","authors":"T. Shirotsuka, R. Ohyama","doi":"10.1109/CEIDP.2006.312090","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312090","url":null,"abstract":"A new type ozone generator with local dielectric barrier discharges operated in very thin gas jets has been experimentally investigated for evaluating an efficient generation process of the ozonic atmosphere. The use of gas jets is to improve an enhancement of the barrier discharges and a cooling effect on the efficiency. The experiments have been conducted to characterize the ozone generation process under following variable parameters: inputted discharge power from a high-voltage source, flow rate of the injected gas jets, and discharge electrode arrangements for optimizing the efficiency. In this paper, a fundamental design of the ozone generator and some quantitative results are presented. The experimentally obtained evaluation indicates an effective performance for the efficiency in a lower range of discharge power.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126585184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Linear Discriminant Analysis for Partial Discharge Classification on High Voltage Equipment 高压设备局部放电分类的线性判别分析
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312010
V. Chatpattananan
This document is addressing a problem in classifying partial discharge types using linear discriminant analysis. Four PD types generated in the lab are corona at high voltage side in air, corona at low voltage side in air, surface in air, and internal discharge. The independent variables used in this linear discriminant analysis model mainly are from skewness, kurtosis, asymmetry, and cross correlation following the Phi - q - n PD patterns obtained from the fingerprint analysis which is a digital signal processing technique for PD measurement. This document also applied step wise model selection technique to reduce from 10 independent variables to 8 independent variables that not only reduces the complexity of the model estimated but also retains the accuracy of this predictive model to 98.7 percent.
本文讨论了用线性判别分析对局部放电类型进行分类的问题。实验室产生的四种放电类型分别是空气高压侧电晕、空气低压侧电晕、空气表面电晕和内部放电。该线性判别分析模型中使用的自变量主要来自指纹分析得到的Phi - q - n PD模式的偏度、峰度、不对称性和相互关系,这是一种用于PD测量的数字信号处理技术。本文还应用了分步模型选择技术,将10个自变量减少到8个自变量,不仅降低了模型估计的复杂性,而且使预测模型的准确率保持在98.7%。
{"title":"Linear Discriminant Analysis for Partial Discharge Classification on High Voltage Equipment","authors":"V. Chatpattananan","doi":"10.1109/CEIDP.2006.312010","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312010","url":null,"abstract":"This document is addressing a problem in classifying partial discharge types using linear discriminant analysis. Four PD types generated in the lab are corona at high voltage side in air, corona at low voltage side in air, surface in air, and internal discharge. The independent variables used in this linear discriminant analysis model mainly are from skewness, kurtosis, asymmetry, and cross correlation following the Phi - q - n PD patterns obtained from the fingerprint analysis which is a digital signal processing technique for PD measurement. This document also applied step wise model selection technique to reduce from 10 independent variables to 8 independent variables that not only reduces the complexity of the model estimated but also retains the accuracy of this predictive model to 98.7 percent.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125208778","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of conditions of partial discharges inception and development at non-sinusoidal testing voltages 非正弦测试电压下局部放电发生和发展的条件分析
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312015
B. Florkowska, P. Zydroń
Progress in construction of electrical insulation systems needs new investigations of partial discharges (PD) mechanisms. Working conditions and exploitation stresses, i.e. overvoltages, harmonics and other disturbances have crucial influence on arising of PD in insulation systems. Their influence on partial discharge development is different from normal conditions at nominal sinusoidal voltage. In such a cases interpretation of measurement results (by classical or phase-resolved PD images method) could be more difficult. Paper presents influence of sinusoidal and non-sinusoidal testing voltages (triangular and trapezoidal) on partial discharge distributions, their parameters and changes with increasing of applied voltage. The test object was real insulation system (stator bar thermo-setting insulation system) with many internal PD sources. Presented results of measurements made for sinusoidal, triangular and trapezoidal voltages show the PD mechanism in these conditions. Slew-rate of applied voltage with fixed peak voltage value determines specific conditions for PD generation and has important consequences for phase location of discharges.
电气绝缘系统建设的进步需要对局部放电机制进行新的研究。工作条件和开发应力,即过电压、谐波和其他干扰对绝缘系统中局部放电的产生有重要影响。它们对局部放电发展的影响不同于名义正弦电压下的正常情况。在这种情况下,解释测量结果(通过经典或相位分辨PD图像方法)可能会更加困难。本文介绍了正弦波和非正弦波测试电压(三角形和梯形)对局部放电分布的影响,以及局部放电分布的参数和随外加电压增加的变化。试验对象为具有多个内部PD源的真实绝缘系统(定子棒热固性绝缘系统)。对正弦、三角形和梯形电压的测量结果显示了在这些条件下的局部放电机制。电压峰值值固定时施加电压的变化率决定了局部放电产生的特定条件,并对放电的相位定位有重要影响。
{"title":"Analysis of conditions of partial discharges inception and development at non-sinusoidal testing voltages","authors":"B. Florkowska, P. Zydroń","doi":"10.1109/CEIDP.2006.312015","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312015","url":null,"abstract":"Progress in construction of electrical insulation systems needs new investigations of partial discharges (PD) mechanisms. Working conditions and exploitation stresses, i.e. overvoltages, harmonics and other disturbances have crucial influence on arising of PD in insulation systems. Their influence on partial discharge development is different from normal conditions at nominal sinusoidal voltage. In such a cases interpretation of measurement results (by classical or phase-resolved PD images method) could be more difficult. Paper presents influence of sinusoidal and non-sinusoidal testing voltages (triangular and trapezoidal) on partial discharge distributions, their parameters and changes with increasing of applied voltage. The test object was real insulation system (stator bar thermo-setting insulation system) with many internal PD sources. Presented results of measurements made for sinusoidal, triangular and trapezoidal voltages show the PD mechanism in these conditions. Slew-rate of applied voltage with fixed peak voltage value determines specific conditions for PD generation and has important consequences for phase location of discharges.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131021276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Experimental Study of Electrohydrodynamic Pumping Feasibility In Microgravity Condition through Conduction Phenomenon 微重力条件下通过传导现象的电液动力泵可行性实验研究
Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312087
M. Ashjaee, S. R. Mahmoudi
In the microgravity condition, circulation of liquids with low level of power consumption is extremely attractive. Electrohydrodynamic pumps generate significant pressure heads with low level of power consumption, simple design, low vibration, and acoustic noise. Moreover, the appropriate electrohydrodynamic pressure heads can be achieved easily with variation of applied voltage. Among the electrohydrodynamic pumping methods, the EHD-conduction pumping has a special feature. Owing to the absence of the ion injection effects, the physical and electrical properties of the working fluid remain constant. Pumping through conduction phenomenon is experimentally investigated. An EHD-pump in a horizontal axisymmetric configuration is tested. The working fluids are selected based on their viscosity difference. These two working fluid, Shell Diala AX and 10-GBN Nynas, have the same conductivity approximately. The generated head in the absence of the gravity is obtained. Velocities up to the 0.4 m/s with 0.9 w can be achieved. In the microgravity condition, the viscous forces are balanced just with Electric forces generated by EHD-Pumps. The EHD-conduction pumps promise good chance to use as a circulation pump in cooling or lubricating systems in microgravity condition with low power consumption and without degradation of working fluid.
在微重力条件下,低能耗的液体循环极具吸引力。电液动力泵产生显著的压头,功耗低,设计简单,振动小,噪音小。此外,随着施加电压的变化,可以很容易地获得合适的电液动压头。在电液动力泵送方式中,ehd传导泵送具有其独特的特点。由于没有离子注入效应,工作流体的物理和电学性质保持不变。实验研究了通过传导泵送现象。对卧式轴对称泵进行了试验研究。工作流体是根据粘度差来选择的。壳牌Diala AX和10-GBN nnnas这两种工质具有近似相同的电导率。得到了无重力条件下的生成水头。速度可达0.4 m/s,功率为0.9 w。在微重力条件下,粘性力刚好与ehd泵产生的电力平衡。ehd传导泵有望在微重力条件下作为冷却或润滑系统的循环泵,具有低功耗和不降解工作流体的优点。
{"title":"Experimental Study of Electrohydrodynamic Pumping Feasibility In Microgravity Condition through Conduction Phenomenon","authors":"M. Ashjaee, S. R. Mahmoudi","doi":"10.1109/CEIDP.2006.312087","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312087","url":null,"abstract":"In the microgravity condition, circulation of liquids with low level of power consumption is extremely attractive. Electrohydrodynamic pumps generate significant pressure heads with low level of power consumption, simple design, low vibration, and acoustic noise. Moreover, the appropriate electrohydrodynamic pressure heads can be achieved easily with variation of applied voltage. Among the electrohydrodynamic pumping methods, the EHD-conduction pumping has a special feature. Owing to the absence of the ion injection effects, the physical and electrical properties of the working fluid remain constant. Pumping through conduction phenomenon is experimentally investigated. An EHD-pump in a horizontal axisymmetric configuration is tested. The working fluids are selected based on their viscosity difference. These two working fluid, Shell Diala AX and 10-GBN Nynas, have the same conductivity approximately. The generated head in the absence of the gravity is obtained. Velocities up to the 0.4 m/s with 0.9 w can be achieved. In the microgravity condition, the viscous forces are balanced just with Electric forces generated by EHD-Pumps. The EHD-conduction pumps promise good chance to use as a circulation pump in cooling or lubricating systems in microgravity condition with low power consumption and without degradation of working fluid.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114668909","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1