An analysis of Intelligent Demand Management criteria applied in a building case study 智能需求管理准则在楼宇个案研究中的应用分析
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478881
C. Quintero M., J. Jiménez Mares
The power consumption in buildings represent a 30-40% of the final energy usage, which is caused by: HVAC (Heating, Ventilation and Air Conditioning), lighting and appliances with any connection to the power grid. The major challenge is to minimize the power consumption by optimizing the operation of several loads without impact in the customer's comfort. For this purpose, the design of an Intelligent Demand Management using Intelligent Systems is presented in this paper. Furthermore a comparative analysis is carried out to evaluate the power consumption performance of some Demand Side Management (DSM) techniques. In this case Direct Load Control (DLC), Load Priority (LP) and Scheduled Programming (SP) are compared with the proposed approach based on Artificial Neural Networks (ANNs). Experimental testing is performed with the consumption data base. The testing results show that energy savings can be achieved through control of the states of various loads.
建筑物的电力消耗占最终能源使用量的30-40%,这是由暖通空调(采暖,通风和空调),照明和任何连接到电网的电器引起的。主要的挑战是在不影响客户舒适度的情况下,通过优化多个负载的运行来最大限度地减少功耗。为此,本文设计了一个基于智能系统的智能需求管理系统。此外,对一些需求侧管理(DSM)技术的电力消耗性能进行了比较分析。将直接负荷控制(DLC)、负荷优先级(LP)和调度规划(SP)与基于人工神经网络(ann)的方法进行了比较。利用消费数据库进行了实验测试。测试结果表明,通过控制各种负载的状态可以实现节能。
{"title":"An analysis of Intelligent Demand Management criteria applied in a building case study","authors":"C. Quintero M., J. Jiménez Mares","doi":"10.1109/SIFAE.2012.6478881","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478881","url":null,"abstract":"The power consumption in buildings represent a 30-40% of the final energy usage, which is caused by: HVAC (Heating, Ventilation and Air Conditioning), lighting and appliances with any connection to the power grid. The major challenge is to minimize the power consumption by optimizing the operation of several loads without impact in the customer's comfort. For this purpose, the design of an Intelligent Demand Management using Intelligent Systems is presented in this paper. Furthermore a comparative analysis is carried out to evaluate the power consumption performance of some Demand Side Management (DSM) techniques. In this case Direct Load Control (DLC), Load Priority (LP) and Scheduled Programming (SP) are compared with the proposed approach based on Artificial Neural Networks (ANNs). Experimental testing is performed with the consumption data base. The testing results show that energy savings can be achieved through control of the states of various loads.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123295754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A performance comparison for wind power integration into the grid system 风电并网系统的性能比较
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478879
Felipe Valencia, J. Patino, Jairo Espinosa
The integration level of wind power into the grid system over the world has been growing at a very fast rate in the last few years and is still keeping this pace. In the future, wind power is expected to be at least comparable to the conventional power generation systems. Large-scale wind farms will need to be integrated into traditional power grid systems, creating the need to establish technical standards to make this integration feasible. This paper covers the performance comparison of a power system with and without the inclusion of a large-scale wind farm. The global system model is presented along to a case of study and the simulation results.
在过去的几年中,世界范围内风电并入电网的水平一直在以非常快的速度增长,并且仍在保持这一速度。在未来,风力发电预计至少可以与传统发电系统相媲美。大型风力发电场将需要整合到传统的电网系统中,这就需要建立技术标准,使这种整合变得可行。本文介绍了一个电力系统的性能比较,包括和不包括一个大型风电场。给出了系统的整体模型,并给出了一个研究实例和仿真结果。
{"title":"A performance comparison for wind power integration into the grid system","authors":"Felipe Valencia, J. Patino, Jairo Espinosa","doi":"10.1109/SIFAE.2012.6478879","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478879","url":null,"abstract":"The integration level of wind power into the grid system over the world has been growing at a very fast rate in the last few years and is still keeping this pace. In the future, wind power is expected to be at least comparable to the conventional power generation systems. Large-scale wind farms will need to be integrated into traditional power grid systems, creating the need to establish technical standards to make this integration feasible. This paper covers the performance comparison of a power system with and without the inclusion of a large-scale wind farm. The global system model is presented along to a case of study and the simulation results.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"226 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114275444","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design and implementation of one LEMP simulator for testing an RF-based Lightning Detector integrated to a PQ Monitoring System 设计和实现一个LEMP模拟器,用于测试集成到PQ监控系统中的基于rf的闪电探测器
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478885
L. F. Diaz-Cadavid, E. Cano-Plata, C. Younes
This paper presents a proposal for a LEMP simulator circuit for testing an RF-Based Lightning Detector integrated into a PQ Monitoring System to which was added the feature of Auto Correlation of power disturbances with the LEMP spectral components.
本文提出了一种用于测试集成在PQ监测系统中的射频雷电探测器的LEMP仿真电路,该电路增加了功率干扰与LEMP频谱分量的自相关特性。
{"title":"Design and implementation of one LEMP simulator for testing an RF-based Lightning Detector integrated to a PQ Monitoring System","authors":"L. F. Diaz-Cadavid, E. Cano-Plata, C. Younes","doi":"10.1109/SIFAE.2012.6478885","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478885","url":null,"abstract":"This paper presents a proposal for a LEMP simulator circuit for testing an RF-Based Lightning Detector integrated into a PQ Monitoring System to which was added the feature of Auto Correlation of power disturbances with the LEMP spectral components.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121892146","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simulation of vertical axis water turbines 垂直轴水轮机的仿真
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478908
S. Laín, B. Quintero, D. Trujillo, Y. Ulianov
This study presents three-dimensional numerical simulations of a cross-flow vertical-axis marine current turbine (straight-bladed Darrieus type) with particular emphasis on rotor-performance prediction and hydrodynamic characteristics. Numerical investigations of a model turbine (power coefficient and flow behaviour) were undertaken using developed computational models. Turbine design was studied using a time-accurate Reynolds-averaged Navier-Stokes (RANS) commercial solver (ANSYS-CFX v. 12). A physical transient rotor-stator model with a sliding mesh technique was used to capture change in flow field at a particular time step. A shear stress transport k-ω turbulence model was used to model turbulent features of the flow. Developed model can effectively predict hydrodynamic performance of a vertical-axis marine current turbine.
本文对横流垂直轴海流透平(直叶Darrieus型)进行了三维数值模拟,重点研究了转子性能预测和流体动力特性。利用已开发的计算模型对模型涡轮(功率系数和流动特性)进行了数值研究。涡轮设计采用时间精确的reynolds -average Navier-Stokes (RANS)商业求解器(ANSYS-CFX v. 12)进行研究。采用滑动网格技术建立物理瞬态转子-定子模型,捕捉特定时间步长的流场变化。采用剪切应力输运k-ω湍流模型来模拟流动的湍流特征。所建立的模型可以有效地预测立式海流水轮机的水动力性能。
{"title":"Simulation of vertical axis water turbines","authors":"S. Laín, B. Quintero, D. Trujillo, Y. Ulianov","doi":"10.1109/SIFAE.2012.6478908","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478908","url":null,"abstract":"This study presents three-dimensional numerical simulations of a cross-flow vertical-axis marine current turbine (straight-bladed Darrieus type) with particular emphasis on rotor-performance prediction and hydrodynamic characteristics. Numerical investigations of a model turbine (power coefficient and flow behaviour) were undertaken using developed computational models. Turbine design was studied using a time-accurate Reynolds-averaged Navier-Stokes (RANS) commercial solver (ANSYS-CFX v. 12). A physical transient rotor-stator model with a sliding mesh technique was used to capture change in flow field at a particular time step. A shear stress transport k-ω turbulence model was used to model turbulent features of the flow. Developed model can effectively predict hydrodynamic performance of a vertical-axis marine current turbine.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125242238","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design of a photovoltaic-wind power generation system with grid connection and two micro-grids 并网双微网光伏-风力发电系统设计
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478886
German Alfonso Osma Pinto, G. O. Plata
This paper presents the design of a hybrid photovoltaic-wind power generation system with an installed capacity of 27,6 kW for the Complejo E3T of the Universidad Industrial de Santander. The system consists of five subsystems, four photovoltaic (97,46%) and one wind power (2,54%). The system will generate 40 MWh per year, it will have a predominantly injection of kind grid-tied (95%); but also it will have storage energy from batteries in two micro-grids to ensure supplies to specific loads, both AC or DC (5%).
本文介绍了桑坦德工业大学E3T综合体装机容量为27,6 kW的光伏-风力混合发电系统的设计。该系统由五个子系统组成,四个光伏(97,46%)和一个风电(2,54%)。该系统将产生40兆瓦时/年,它将有主要的注入类型并网(95%);而且它还将在两个微电网中储存来自电池的能量,以确保向特定负载供电,无论是交流还是直流(5%)。
{"title":"Design of a photovoltaic-wind power generation system with grid connection and two micro-grids","authors":"German Alfonso Osma Pinto, G. O. Plata","doi":"10.1109/SIFAE.2012.6478886","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478886","url":null,"abstract":"This paper presents the design of a hybrid photovoltaic-wind power generation system with an installed capacity of 27,6 kW for the Complejo E3T of the Universidad Industrial de Santander. The system consists of five subsystems, four photovoltaic (97,46%) and one wind power (2,54%). The system will generate 40 MWh per year, it will have a predominantly injection of kind grid-tied (95%); but also it will have storage energy from batteries in two micro-grids to ensure supplies to specific loads, both AC or DC (5%).","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133844934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Effects of PV interconnection system to a circuit of a distribution network 光伏并网系统对配电网回路的影响
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478892
J. Cabrera, I. Medina, J. Hernández
This paper analyzes the effect of the implementation of photovoltaic systems interconnected to a branch circuit of an electricity distribution network in the city of Bogota. By computational simulations NEPLAN tool, connecting the photovoltaic system to the network, the change is evidenced in the direction of power flow, the variation in the levels of voltage, current and power losses, which are then compared with voltage values obtained from Colombian rule governing maximum and minimum levels in the distribution network. Somehow this article contributes to the increase of projects with renewable energy such as developing it demonstrates the improvement that would be implemented in story to operating conditions of the distribution network, improving voltage profiles, complying with the limits established by regulation voltage, and decreasing the amount of current flowing through the conductors, which generates an increase of the useful life thereof. It should be noted that these results are valid under the conditions previously established, and that in a different context can present a different performance.
本文分析了在波哥大市将光伏系统连接到配电网分支电路的实施效果。通过NEPLAN工具的计算模拟,将光伏系统接入电网,验证了潮流方向的变化,电压、电流和功率损耗的变化,并将其与配电网中最大和最小电平的哥伦比亚规则得到的电压值进行了比较。在某种程度上,本文有助于增加使用可再生能源的项目,例如开发它展示了将在配电网运行条件下实施的改进,改善电压分布,符合调节电压规定的限制,减少流过导体的电流,从而增加其使用寿命。应该注意的是,这些结果在先前建立的条件下是有效的,在不同的上下文中可能呈现不同的性能。
{"title":"Effects of PV interconnection system to a circuit of a distribution network","authors":"J. Cabrera, I. Medina, J. Hernández","doi":"10.1109/SIFAE.2012.6478892","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478892","url":null,"abstract":"This paper analyzes the effect of the implementation of photovoltaic systems interconnected to a branch circuit of an electricity distribution network in the city of Bogota. By computational simulations NEPLAN tool, connecting the photovoltaic system to the network, the change is evidenced in the direction of power flow, the variation in the levels of voltage, current and power losses, which are then compared with voltage values obtained from Colombian rule governing maximum and minimum levels in the distribution network. Somehow this article contributes to the increase of projects with renewable energy such as developing it demonstrates the improvement that would be implemented in story to operating conditions of the distribution network, improving voltage profiles, complying with the limits established by regulation voltage, and decreasing the amount of current flowing through the conductors, which generates an increase of the useful life thereof. It should be noted that these results are valid under the conditions previously established, and that in a different context can present a different performance.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"268 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114941631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characterization of power quality disturbances using digital filtering techniques 使用数字滤波技术表征电能质量扰动
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478882
D. Montenegro, G. Ramos, W. Vallejo
This paper presents a characterization of the solar resource behavior for ten cities of Colombia. This study was made from solar radiation and ambient temperature data collected by the Instituto de Hidrología, Meteorología y Estudios Ambientales de Colombia IDEAM. According to the analyzes, we determined which of these ten cities are the best potential for developing solar energy projects.
本文介绍了哥伦比亚十个城市的太阳能资源行为特征。这项研究是根据哥伦比亚环境研究中心(IDEAM) Hidrología, Meteorología研究所收集的太阳辐射和环境温度数据进行的。根据分析,我们确定了这十个城市中哪一个最有潜力发展太阳能项目。
{"title":"Characterization of power quality disturbances using digital filtering techniques","authors":"D. Montenegro, G. Ramos, W. Vallejo","doi":"10.1109/SIFAE.2012.6478882","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478882","url":null,"abstract":"This paper presents a characterization of the solar resource behavior for ten cities of Colombia. This study was made from solar radiation and ambient temperature data collected by the Instituto de Hidrología, Meteorología y Estudios Ambientales de Colombia IDEAM. According to the analyzes, we determined which of these ten cities are the best potential for developing solar energy projects.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116043878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Small signal stability analysis of Jepirachi wind park Jepirachi风电场小信号稳定性分析
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478909
Y. Ulianov, S. Laín
The actual development of wind energy in several countries around the world become it as the fastest growing power generation technology between green and clean technologies. Almost 50% of the installed wind turbines are induction generators. With the increase of induction instead of synchronous generators, electrical networks are experiencing different disturbances, which require permanent transient and small signal stability studies. This article presents an analysis of a small signal stability study in the first wind park installed in Colombia. In this analysis a software VORTEXOFT developed by the authors is used for aerodynamic purposes. A modal analysis and eigenvalues were done considering high level of wind power penetration. The results obtained indicate that the proposed method effectively identifies the stability operational point for a high level of wind power.
风能在世界上几个国家的实际发展使其成为介于绿色和清洁技术之间发展最快的发电技术。已安装的风力涡轮机中几乎有50%是感应发电机。随着异步发电机而非同步发电机的增加,电网面临着各种各样的干扰,这就需要进行永久暂态和小信号稳定性的研究。本文介绍了在哥伦比亚安装的第一个风电场中进行的小信号稳定性研究的分析。在本分析中,使用了作者开发的用于气动目的的软件VORTEXOFT。考虑高水平风电穿透,进行了模态分析和特征值分析。结果表明,该方法能有效地确定高电平风电的稳定工作点。
{"title":"Small signal stability analysis of Jepirachi wind park","authors":"Y. Ulianov, S. Laín","doi":"10.1109/SIFAE.2012.6478909","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478909","url":null,"abstract":"The actual development of wind energy in several countries around the world become it as the fastest growing power generation technology between green and clean technologies. Almost 50% of the installed wind turbines are induction generators. With the increase of induction instead of synchronous generators, electrical networks are experiencing different disturbances, which require permanent transient and small signal stability studies. This article presents an analysis of a small signal stability study in the first wind park installed in Colombia. In this analysis a software VORTEXOFT developed by the authors is used for aerodynamic purposes. A modal analysis and eigenvalues were done considering high level of wind power penetration. The results obtained indicate that the proposed method effectively identifies the stability operational point for a high level of wind power.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126223330","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Environmental Transmission Expansion Planning using non-linear programming and evolutionary techniques 使用非线性规划和进化技术的环境传输扩展规划
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478893
C. Correa, R. Bolanos, Alejandro Garces
Current energy consumption has led to an increase in the use of fossil fuels to generate electricity, which in turn produces negative impacts on the environment. Studies show that demand will continue growing and new schemes for generating power and managing resources should be developed. In the case of the transmission network, some constraints may lead to use plants with high emission levels, and therefore, appropriate planning is key to minimize environmental impact. This work proposes a methodology for solving the Transmission Expansion Planning Problem (TEPP) when emissions of CO2 are considered. The result is an investment plan that leads to the lowest level of emissions by means of a Chu-Beasley Genetic Algorithm (CBGA). An improvement step is carried in the CBGA in order to minimize also the cost of the plan. Non-linear Interior Point Method (NLIPM) is used to generate the initial population and Linear (LIPM) is used to solve the operative problem in the evolutionary process. The approach is validated using the IEEE-24 bus system in order to show its effectiveness.
目前的能源消耗导致化石燃料发电的使用增加,这反过来又对环境产生负面影响。研究表明,需求将继续增长,应该制定新的发电和资源管理方案。在输电网的情况下,一些限制可能导致使用高排放水平的工厂,因此,适当的规划是最大限度地减少环境影响的关键。本文提出了一种考虑二氧化碳排放时解决输电扩展规划问题(TEPP)的方法。利用丘-比斯利遗传算法(chui - beasley Genetic Algorithm, CBGA),得出了实现最低排放水平的投资方案。在CBGA中进行了改进步骤,以最小化计划的成本。采用非线性内点法(NLIPM)生成初始种群,采用线性法(LIPM)求解演化过程中的操作问题。利用IEEE-24总线系统验证了该方法的有效性。
{"title":"Environmental Transmission Expansion Planning using non-linear programming and evolutionary techniques","authors":"C. Correa, R. Bolanos, Alejandro Garces","doi":"10.1109/SIFAE.2012.6478893","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478893","url":null,"abstract":"Current energy consumption has led to an increase in the use of fossil fuels to generate electricity, which in turn produces negative impacts on the environment. Studies show that demand will continue growing and new schemes for generating power and managing resources should be developed. In the case of the transmission network, some constraints may lead to use plants with high emission levels, and therefore, appropriate planning is key to minimize environmental impact. This work proposes a methodology for solving the Transmission Expansion Planning Problem (TEPP) when emissions of CO2 are considered. The result is an investment plan that leads to the lowest level of emissions by means of a Chu-Beasley Genetic Algorithm (CBGA). An improvement step is carried in the CBGA in order to minimize also the cost of the plan. Non-linear Interior Point Method (NLIPM) is used to generate the initial population and Linear (LIPM) is used to solve the operative problem in the evolutionary process. The approach is validated using the IEEE-24 bus system in order to show its effectiveness.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116168256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Compensation of DC-link voltage oscillations in grid-connected PV systems based on high order dc/dc converters 基于高阶dc/dc变换器的并网光伏系统直流链路电压振荡补偿
Pub Date : 2012-10-01 DOI: 10.1109/SIFAE.2012.6478884
A. Trejos, C. Ramos-Paja, S. Serna
The development on PV applications along with recent breakthroughs in power electronics has became in a strong research area especially in modeling and control techniques. This paper presents an analysis of grid-connected photovoltaic systems using three different high-order dc/dc topologies: Cuk converter, SEPIC converter and Zeta converter. This work considers ideal PV systems and a voltage load model is used, which is a common model for large DC-links. A technique for compensation of voltage oscillations is introduced as an alternative to the common use of electrolytic capacitors which introduce reliability problems. The systems are tested through simulation to validate the analysis performed and finally some conclusions about results are given.
随着近年来电力电子技术的突破,光伏应用的发展已经成为一个强大的研究领域,特别是在建模和控制技术方面。本文分析了三种不同的高阶dc/dc拓扑:Cuk变换器、SEPIC变换器和Zeta变换器并网光伏系统。这项工作考虑了理想的光伏系统,并使用了电压负载模型,这是大型直流链路的常用模型。介绍了一种补偿电压振荡的技术,作为一种替代常用的电解电容器引入可靠性问题的方法。通过仿真对系统进行了测试,验证了所做的分析,最后给出了一些结论。
{"title":"Compensation of DC-link voltage oscillations in grid-connected PV systems based on high order dc/dc converters","authors":"A. Trejos, C. Ramos-Paja, S. Serna","doi":"10.1109/SIFAE.2012.6478884","DOIUrl":"https://doi.org/10.1109/SIFAE.2012.6478884","url":null,"abstract":"The development on PV applications along with recent breakthroughs in power electronics has became in a strong research area especially in modeling and control techniques. This paper presents an analysis of grid-connected photovoltaic systems using three different high-order dc/dc topologies: Cuk converter, SEPIC converter and Zeta converter. This work considers ideal PV systems and a voltage load model is used, which is a common model for large DC-links. A technique for compensation of voltage oscillations is introduced as an alternative to the common use of electrolytic capacitors which introduce reliability problems. The systems are tested through simulation to validate the analysis performed and finally some conclusions about results are given.","PeriodicalId":330140,"journal":{"name":"2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127553846","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
期刊
2012 IEEE International Symposium on Alternative Energies and Energy Quality (SIFAE)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1