Foult Indicator for polymeric insulators on 72.5 KV structures 72.5 KV结构上聚合物绝缘子的故障指示器
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453598
A. A. M. de Albuquerque, R. G. D. Filho, A. L. C. Araujo
The fault location in electric energy transmission structures using polymeric insulators is difficult to protect, since there are no visible signs of usage. This paper presents a real time failure detection system in polymeric insulators using an electronic system that measures the eletric current escape. The system stores leakage currents on the log file at regular time intervals and sends data to a server through a system of wireless sensor networks (WSN). A backup system is responsible for analyzing the values of each structure and generates alarms if certain current values are exceeded. The system was validated in the field on a power company distribution network.
在使用聚合物绝缘体的电力传输结构中,故障位置难以保护,因为没有明显的使用迹象。本文介绍了一种利用电子系统测量电流逸出的聚合物绝缘子故障实时检测系统。该系统定期将泄漏电流存储在日志文件中,并通过无线传感器网络(WSN)系统将数据发送到服务器。备份系统负责分析每个结构的电流值,并在超过某些电流值时产生告警。该系统在某电力公司配电网上进行了现场验证。
{"title":"Foult Indicator for polymeric insulators on 72.5 KV structures","authors":"A. A. M. de Albuquerque, R. G. D. Filho, A. L. C. Araujo","doi":"10.1109/INDUSCON.2012.6453598","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453598","url":null,"abstract":"The fault location in electric energy transmission structures using polymeric insulators is difficult to protect, since there are no visible signs of usage. This paper presents a real time failure detection system in polymeric insulators using an electronic system that measures the eletric current escape. The system stores leakage currents on the log file at regular time intervals and sends data to a server through a system of wireless sensor networks (WSN). A backup system is responsible for analyzing the values of each structure and generates alarms if certain current values are exceeded. The system was validated in the field on a power company distribution network.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"1 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131463038","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A grid-connected photovoltaic system with a maximum power point tracker using passivity-based control applied in a boost converter 在升压变换器中采用无源控制的最大功率点跟踪器并网光伏系统
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6452753
A. F. Cupertino, J. T. de Resende, H. Pereira, S. I. Seleme Junior
The power generated by a solar photovoltaic panel is strongly dependent on climate conditions. For this reason, a grid-connected system needs a good response for variations in the solar irradiance and temperature. A non-linear control technique which has a good rejection of disturbances is the passivity-based control. This work presents the application of the passivity-based control in a maximum power tracker boost converter for a grid-connected photovoltaic system. The fast response of the control allows a better use of the photovoltaic array energy, increasing the efficiency of the system, and ensuring stability for all operation range.
太阳能光伏板产生的能量很大程度上取决于气候条件。因此,并网系统需要对太阳辐照度和温度的变化有良好的响应。基于无源的控制是一种具有良好抗干扰性的非线性控制技术。本文介绍了基于无源控制的最大功率跟踪升压变换器在并网光伏系统中的应用。控制的快速响应可以更好地利用光伏阵列的能量,提高系统的效率,并确保整个运行范围的稳定性。
{"title":"A grid-connected photovoltaic system with a maximum power point tracker using passivity-based control applied in a boost converter","authors":"A. F. Cupertino, J. T. de Resende, H. Pereira, S. I. Seleme Junior","doi":"10.1109/INDUSCON.2012.6452753","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6452753","url":null,"abstract":"The power generated by a solar photovoltaic panel is strongly dependent on climate conditions. For this reason, a grid-connected system needs a good response for variations in the solar irradiance and temperature. A non-linear control technique which has a good rejection of disturbances is the passivity-based control. This work presents the application of the passivity-based control in a maximum power tracker boost converter for a grid-connected photovoltaic system. The fast response of the control allows a better use of the photovoltaic array energy, increasing the efficiency of the system, and ensuring stability for all operation range.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131752782","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 27
A study of shunt active power filter based on modular multilevel converter (MMC) 基于模块化多电平变换器(MMC)的并联有源电力滤波器研究
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453236
Frederico T. Ghetti, A. Ferreira, H. Braga, P. G. Barbosa
This paper presents a study of a shunt active power filter based on the modular multilevel converter (MMC) topology. The current controller of the shunt active power filter uses a PI-MRI (PI with multi reference frame integrators) technique to assure that the APF current tracks the reference signal. It is also investigated the performance of the method of selection and classification used to choose and to control which submodule (SM) of the MMC will become active. Simulation results will be used to evaluate and to demonstrate the behavior of MMC as active power filter.
本文研究了一种基于模块化多电平变换器(MMC)拓扑结构的并联型有源电力滤波器。并联型有源电力滤波器的电流控制器采用PI- mri (PI与多参考帧积分器)技术来保证有源滤波器电流跟踪参考信号。研究了选择和分类方法的性能,用于选择和控制MMC的哪个子模块(SM)将处于活动状态。仿真结果将用于评估和演示MMC作为有源电力滤波器的性能。
{"title":"A study of shunt active power filter based on modular multilevel converter (MMC)","authors":"Frederico T. Ghetti, A. Ferreira, H. Braga, P. G. Barbosa","doi":"10.1109/INDUSCON.2012.6453236","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453236","url":null,"abstract":"This paper presents a study of a shunt active power filter based on the modular multilevel converter (MMC) topology. The current controller of the shunt active power filter uses a PI-MRI (PI with multi reference frame integrators) technique to assure that the APF current tracks the reference signal. It is also investigated the performance of the method of selection and classification used to choose and to control which submodule (SM) of the MMC will become active. Simulation results will be used to evaluate and to demonstrate the behavior of MMC as active power filter.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132928391","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 32
Comparing performance of classical methods for service restoration in MV networks with a new method based on sensitivity parameters 比较了经典中压网络业务恢复方法与基于灵敏度参数的新方法的性能
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451726
J. L. da Silva, M. F. Medeiros, Max Chianca Pimentel Filho
The objective of this paper is to demonstrate the validity of the use of sensibility parameters as a low computational cost tool to implement service restoration in medium voltage distribution networks. A linearization of the relationship between accumulated powers - active and reactive - in a node and the voltages of all nodes can be carried out by means of sensitivity parameters, in order to determine the influence in voltages, caused by variations in powers in the network nodes as intending supply restoration of loads. The validity of this analysis tool is made comparing it with the restoration/reconfiguration classical methods that uses either a constructive process or an opening process of mesh. It was observed that the service restoration by the use of sensitivity parameters normally presents a very small number of complete calculations of load flow when compared with the classical methods, in addition to a significant reduction in the switching operations, with obvious advantages in the time of restoration, and in the rates of network reliability.
本文的目的是证明使用敏感性参数作为一种低计算成本工具来实现中压配电网的业务恢复的有效性。一个节点的累计功率(有功和无功)与所有节点的电压之间的线性化关系可以通过灵敏度参数进行,以确定电压的影响,在网络节点的功率变化引起的预期供电恢复负载。将该分析工具与传统的网格构造过程和网格开放过程的恢复重构方法进行比较,验证了该分析工具的有效性。结果表明,与传统方法相比,利用灵敏度参数进行业务恢复的负荷流完整计算次数很少,而且能显著减少切换操作,在恢复时间和网络可靠性方面具有明显优势。
{"title":"Comparing performance of classical methods for service restoration in MV networks with a new method based on sensitivity parameters","authors":"J. L. da Silva, M. F. Medeiros, Max Chianca Pimentel Filho","doi":"10.1109/INDUSCON.2012.6451726","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451726","url":null,"abstract":"The objective of this paper is to demonstrate the validity of the use of sensibility parameters as a low computational cost tool to implement service restoration in medium voltage distribution networks. A linearization of the relationship between accumulated powers - active and reactive - in a node and the voltages of all nodes can be carried out by means of sensitivity parameters, in order to determine the influence in voltages, caused by variations in powers in the network nodes as intending supply restoration of loads. The validity of this analysis tool is made comparing it with the restoration/reconfiguration classical methods that uses either a constructive process or an opening process of mesh. It was observed that the service restoration by the use of sensitivity parameters normally presents a very small number of complete calculations of load flow when compared with the classical methods, in addition to a significant reduction in the switching operations, with obvious advantages in the time of restoration, and in the rates of network reliability.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131825961","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Behavior of electric vehicles and traction drives during sensor faults 传感器故障时电动汽车和牵引传动的行为
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453764
F. Aguilera, P. M. de la Barrera, C. D. de Angelo
The behavior of an electric vehicle and its electric traction drive under sensor faults is studied in this paper. With this aim, simulations over a vehicle model with rear traction, using an induction machine, were carried out. The drive model can switch between three different conventional control strategies. With this setup, the longitudinal dynamics behavior of the vehicle and the electrical variables of the drive against sensor faults and changes of the control strategy are analyzed. The obtained results are useful in the design of a sensor fault tolerant architecture.
研究了传感器故障情况下电动汽车及其电力牵引传动的性能。为此,利用感应电机对具有后部牵引的车辆模型进行了仿真。驱动模型可以在三种不同的常规控制策略之间切换。在此基础上,分析了传感器故障和控制策略变化对车辆纵向动力学行为和驱动电变量的影响。所得结果可用于传感器容错体系结构的设计。
{"title":"Behavior of electric vehicles and traction drives during sensor faults","authors":"F. Aguilera, P. M. de la Barrera, C. D. de Angelo","doi":"10.1109/INDUSCON.2012.6453764","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453764","url":null,"abstract":"The behavior of an electric vehicle and its electric traction drive under sensor faults is studied in this paper. With this aim, simulations over a vehicle model with rear traction, using an induction machine, were carried out. The drive model can switch between three different conventional control strategies. With this setup, the longitudinal dynamics behavior of the vehicle and the electrical variables of the drive against sensor faults and changes of the control strategy are analyzed. The obtained results are useful in the design of a sensor fault tolerant architecture.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121290061","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
A tool for real time analysis of parallelism of distribution networks 配电网并行度实时分析工具
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451396
L. L. Pfitscher, D. Bernardon, L. Canha, V. Montagner, M. Sperandio, J. Saldanha, M. Ramos
The parallelism of distribution networks can be used to transfer loads between feeders without the need of disconnection of consumers during the switching. In the context of the Smart Grids, the parallelism of feeders can be used in automatic reconfiguration of networks for the improvement of power quality and voltage levels, and reduction of energy losses. However, the switching for parallelism must be preceded by studies to verify their technical and operational feasibility. This paper presents a study that discusses aspects of loading, protection, and voltage levels related to parallelism of networks, in transient and steady-state analysis. The validation of the developed methodology was carried out by comparison of simulation results with the ATP program. The study aims to be suitable for real-time application in reconfiguration of distribution networks. Integration with remote controlled switches, so that the network reconfiguration can be done automatically, is one of the differentials of the work. The tests here presented are made in a real model of a distribution network of a power utility. The developed algorithm has as main result a reliable indication of the technical feasibility of connecting feeders in parallel.
配电网的并行性可以在不需要用户在切换过程中断开连接的情况下在馈线之间传输负荷。在智能电网的背景下,馈线的并行性可以用于网络的自动重构,以提高电能质量和电压水平,减少能量损失。但是,在转向并行之前必须进行研究,以验证其技术和操作可行性。本文提出了一项研究,讨论了在暂态和稳态分析中与网络并行性相关的负载,保护和电压水平方面。通过与ATP程序的仿真结果对比,验证了所开发方法的正确性。研究的目的是为了适应配电网重构的实时应用。与远程控制交换机集成,使网络重新配置可以自动完成,是微分的工作之一。本文所介绍的试验是在实际的配电网模型中进行的。该算法的主要结果可靠地表明了馈线并联的技术可行性。
{"title":"A tool for real time analysis of parallelism of distribution networks","authors":"L. L. Pfitscher, D. Bernardon, L. Canha, V. Montagner, M. Sperandio, J. Saldanha, M. Ramos","doi":"10.1109/INDUSCON.2012.6451396","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451396","url":null,"abstract":"The parallelism of distribution networks can be used to transfer loads between feeders without the need of disconnection of consumers during the switching. In the context of the Smart Grids, the parallelism of feeders can be used in automatic reconfiguration of networks for the improvement of power quality and voltage levels, and reduction of energy losses. However, the switching for parallelism must be preceded by studies to verify their technical and operational feasibility. This paper presents a study that discusses aspects of loading, protection, and voltage levels related to parallelism of networks, in transient and steady-state analysis. The validation of the developed methodology was carried out by comparison of simulation results with the ATP program. The study aims to be suitable for real-time application in reconfiguration of distribution networks. Integration with remote controlled switches, so that the network reconfiguration can be done automatically, is one of the differentials of the work. The tests here presented are made in a real model of a distribution network of a power utility. The developed algorithm has as main result a reliable indication of the technical feasibility of connecting feeders in parallel.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"145 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123772770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Passivity-based control of boost converters using PLL 基于锁相环的升压变换器无源控制
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451384
A. Rosa, S. Junior, L. Morais, P. Cortizo
In the context that involves low and medium powers, boost-type converters have high performance and is therefore strongly recommended to work in regulated sources. However, without adequate control such converters eventually provide high levels of THD (Total Harmonic Distortion) and low power factor (pf). In this way, different authors validated the passivity-based control (PBC) applied to static converters. However, through these studies it was observed that the quality of results is associated with the input signal voltage. Thus, the insertion of the PLL (Phase-Locked Loop) is justified by the poor quality of networks in general. That is usually the power supply voltages are not purely sinusoidal and have very harmonic content. Thus, lower THD levels can be obtained by adding the PLL for imposing a sinusoidal reference signal to the input voltage.
在涉及低功率和中功率的情况下,升压型变流器具有高性能,因此强烈建议在受控源中工作。然而,如果没有足够的控制,这种转换器最终提供高水平的THD(总谐波失真)和低功率因数(pf)。通过这种方式,不同的作者验证了基于无源控制(PBC)应用于静态变流器。然而,通过这些研究发现,结果的质量与输入信号电压有关。因此,锁相环(PLL)的插入在一般的网络质量较差的情况下是合理的。也就是说,通常电源电压不是纯正弦的,而是谐波含量很高的。因此,可以通过添加锁相环来施加正弦参考信号到输入电压来获得较低的THD电平。
{"title":"Passivity-based control of boost converters using PLL","authors":"A. Rosa, S. Junior, L. Morais, P. Cortizo","doi":"10.1109/INDUSCON.2012.6451384","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451384","url":null,"abstract":"In the context that involves low and medium powers, boost-type converters have high performance and is therefore strongly recommended to work in regulated sources. However, without adequate control such converters eventually provide high levels of THD (Total Harmonic Distortion) and low power factor (pf). In this way, different authors validated the passivity-based control (PBC) applied to static converters. However, through these studies it was observed that the quality of results is associated with the input signal voltage. Thus, the insertion of the PLL (Phase-Locked Loop) is justified by the poor quality of networks in general. That is usually the power supply voltages are not purely sinusoidal and have very harmonic content. Thus, lower THD levels can be obtained by adding the PLL for imposing a sinusoidal reference signal to the input voltage.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121532826","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Sensorless direct FOC with Takagi-Sugeno Fuzzy controller for three-phase induction motor 无传感器直接FOC与Takagi-Sugeno模糊控制器三相感应电机
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451398
J. Azcue, A. S. Sguarezi Filho, E. Ruppert
This paper proposes a Takagi-Sugeno (T-S) Fuzzy controller to substitute the two PI current regulators present in conventional sensorless direct field oriented control (DFOC) scheme. The proposed controller calculates the reference quadrature components of the stator voltage vector in rotor-flux-oriented reference frame. The rule base for the proposed controller is defined in function of the stator current direct and quadrature component errors. Constant switching frequency and low torque ripple are obtained using space vector modulation technique. Performance of the proposed sensorless DFOC scheme with T-S fuzzy controller is analyzed in terms of rise time, settling time and torque ripple considering different operating conditions. The fast torque response and low torque ripple are obtained with the proposed scheme as is shown through numerical simulation results.
本文提出了一种Takagi-Sugeno (T-S)模糊控制器来取代传统无传感器直接场定向控制(DFOC)方案中存在的两个PI电流调节器。该控制器计算定子电压矢量在转子磁通定向参考系中的参考正交分量。该控制器的规则库以定子电流、直流分量和正交分量误差为函数定义。采用空间矢量调制技术,获得恒定的开关频率和低转矩脉动。从上升时间、稳定时间和转矩脉动三个方面分析了基于T-S模糊控制器的无传感器DFOC方案在不同工况下的性能。数值仿真结果表明,该方案具有转矩响应快、转矩脉动小的特点。
{"title":"Sensorless direct FOC with Takagi-Sugeno Fuzzy controller for three-phase induction motor","authors":"J. Azcue, A. S. Sguarezi Filho, E. Ruppert","doi":"10.1109/INDUSCON.2012.6451398","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451398","url":null,"abstract":"This paper proposes a Takagi-Sugeno (T-S) Fuzzy controller to substitute the two PI current regulators present in conventional sensorless direct field oriented control (DFOC) scheme. The proposed controller calculates the reference quadrature components of the stator voltage vector in rotor-flux-oriented reference frame. The rule base for the proposed controller is defined in function of the stator current direct and quadrature component errors. Constant switching frequency and low torque ripple are obtained using space vector modulation technique. Performance of the proposed sensorless DFOC scheme with T-S fuzzy controller is analyzed in terms of rise time, settling time and torque ripple considering different operating conditions. The fast torque response and low torque ripple are obtained with the proposed scheme as is shown through numerical simulation results.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"112 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126358036","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Enclosure for fuse cutout against third party intervention 防止第三方介入的熔断器外壳
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451385
L. F. Toledo, A. Lazzaretti, E. L. Kowalski, M. A. Ravaglio, J. Teixeira, V. Simiao, Daniel Campos Negreiros, Matias Soares Neto
This paper describes the development of a prototype of an enclosure for a fuse cutout, for distribution networks of class 15 kV and 36.2 kV. The purpose of the enclosure is to protect the fuse cutout against third party intervention and ensure that only linemen will be able to perform maneuvers and maintenance. Besides protecting the fuse cutout, the enclosure should allow the proper operation of the device while still ensuring signaling the occurrence of events in the distribution network. The enclosure may be used in any fuse cutout, even in operation, with certain nominal characteristics and can still be installed with the line energized.
本文介绍了15kv和36.2 kV配电网熔断器外壳样机的研制。外壳的目的是保护保险丝切断对第三方干预,并确保只有线路人员将能够执行机动和维护。除了保护熔断器外,外壳还应允许设备正常运行,同时仍应确保配电网中发生事件的信号。该外壳可用于任何熔断器,即使在运行中,具有某些标称特性,并且仍然可以安装在通电的线路上。
{"title":"Enclosure for fuse cutout against third party intervention","authors":"L. F. Toledo, A. Lazzaretti, E. L. Kowalski, M. A. Ravaglio, J. Teixeira, V. Simiao, Daniel Campos Negreiros, Matias Soares Neto","doi":"10.1109/INDUSCON.2012.6451385","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451385","url":null,"abstract":"This paper describes the development of a prototype of an enclosure for a fuse cutout, for distribution networks of class 15 kV and 36.2 kV. The purpose of the enclosure is to protect the fuse cutout against third party intervention and ensure that only linemen will be able to perform maneuvers and maintenance. Besides protecting the fuse cutout, the enclosure should allow the proper operation of the device while still ensuring signaling the occurrence of events in the distribution network. The enclosure may be used in any fuse cutout, even in operation, with certain nominal characteristics and can still be installed with the line energized.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124171240","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Single-stage PFC AC-DC converter based on serial-interleaved boost 基于串行交错升压的单级PFC交流-直流变换器
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6452040
C. S. Postiglione, A. Fuerback, D. Martins, A. Perin, C. Nascimento
This paper presents single-stage power factor corrected (PFC) AC-DC converters based on a modified serial-interleaved boost converter. The topologies are a composition of a modified interleaved boost converter with a DC-DC converter. The interleaving allows each boost converter to operate in discontinuous conduction mode (DCM) while still having continuous conduction mode (CCM) input current, resulting in high power factor and reduced current ripple, meeting IEC 61000-3-2 regulations for wide load range. In addition, the converters operate with zero voltage switching (ZVS) resulting in high efficiency. The steady-state analysis of the converter is performed along with the description of the converter operation stages. Finally, a simplified design procedure is proposed, from where a prototype is designed and built. Furthermore, the experimental results from a laboratory prototype are presented.
本文提出了一种基于改进的串交错升压变换器的单级功率因数校正(PFC)交流-直流变换器。该拓扑结构由改进的交错升压变换器和DC-DC变换器组成。交错允许每个升压转换器在断续导通模式(DCM)下工作,同时仍然具有连续导通模式(CCM)输入电流,从而产生高功率因数和减小电流纹波,满足IEC 61000-3-2宽负载范围的规定。此外,变换器在零电压开关(ZVS)下工作,从而提高了效率。对变流器进行了稳态分析,并对其运行阶段进行了描述。最后,提出了一种简化的设计流程,从该流程开始设计和构建原型。此外,还给出了实验室样机的实验结果。
{"title":"Single-stage PFC AC-DC converter based on serial-interleaved boost","authors":"C. S. Postiglione, A. Fuerback, D. Martins, A. Perin, C. Nascimento","doi":"10.1109/INDUSCON.2012.6452040","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6452040","url":null,"abstract":"This paper presents single-stage power factor corrected (PFC) AC-DC converters based on a modified serial-interleaved boost converter. The topologies are a composition of a modified interleaved boost converter with a DC-DC converter. The interleaving allows each boost converter to operate in discontinuous conduction mode (DCM) while still having continuous conduction mode (CCM) input current, resulting in high power factor and reduced current ripple, meeting IEC 61000-3-2 regulations for wide load range. In addition, the converters operate with zero voltage switching (ZVS) resulting in high efficiency. The steady-state analysis of the converter is performed along with the description of the converter operation stages. Finally, a simplified design procedure is proposed, from where a prototype is designed and built. Furthermore, the experimental results from a laboratory prototype are presented.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116949922","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
期刊
2012 10th IEEE/IAS International Conference on Industry Applications
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1