Network topology tracking methodology customized for the fault diagnosis problem in electrical power systems 针对电力系统故障诊断问题的网络拓扑跟踪方法
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6452354
A. Oliveira, G. Dhein, O. Araújo, G. Cardoso, J. M. Zauk, A. F. Brum
This paper presents a data structure developed to track the network topology of electrical power systems with the purpose of interconnecting the supervisory control and data acquisition (SCADA) with a generic alarm processor. The interface between SCADA and alarm processor is achieved by identifying the adjacencies of each disconnected component due to the fault. A network topology tracking methodology is proposed to treat logical measurements of switching devices status and the information of data-base describing the network connectivity. In the fault diagnosis problem, this paper demonstrates that the proposed approach is significantly more efficient than processors reported in the literature because it allows to map and to estimate the origin of a fault using a group of suspect equipment.
本文提出了一种用于跟踪电力系统网络拓扑结构的数据结构,其目的是将监控和数据采集(SCADA)与通用报警处理器互连。SCADA与告警处理器之间的接口是通过识别各故障断开组件的邻接关系来实现的。提出了一种网络拓扑跟踪方法来处理交换设备状态的逻辑测量和描述网络连通性的数据库信息。在故障诊断问题中,本文证明了所提出的方法比文献中报道的处理器更有效,因为它允许使用一组可疑设备来映射和估计故障的起源。
{"title":"Network topology tracking methodology customized for the fault diagnosis problem in electrical power systems","authors":"A. Oliveira, G. Dhein, O. Araújo, G. Cardoso, J. M. Zauk, A. F. Brum","doi":"10.1109/INDUSCON.2012.6452354","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6452354","url":null,"abstract":"This paper presents a data structure developed to track the network topology of electrical power systems with the purpose of interconnecting the supervisory control and data acquisition (SCADA) with a generic alarm processor. The interface between SCADA and alarm processor is achieved by identifying the adjacencies of each disconnected component due to the fault. A network topology tracking methodology is proposed to treat logical measurements of switching devices status and the information of data-base describing the network connectivity. In the fault diagnosis problem, this paper demonstrates that the proposed approach is significantly more efficient than processors reported in the literature because it allows to map and to estimate the origin of a fault using a group of suspect equipment.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"142 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115336670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Long-lifetime SEPIC-buck integrated converter for LED lighting application 用于LED照明应用的长寿命sepic降压集成转换器
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451725
M. Cosetin, P. Luz, M. F. da Silva, F. Bisogno, J. M. Alonso, R. D. do Prado
This paper presents an analysis and design of a Light Emitting Diode (LED) driver aiming to eliminate/substitute the electrolytic capacitors. Considering the low lifetime of electrolytic capacitors compared to LEDs, this topology aims for reducing the storage capacitance and replaces it by a film capacitor, increasing the system lifetime. This reduction is based on designing of the control dynamic with a compromise between the input current distortion and the output current ripple. The power factor correction (PFC) stage is based on a Single Ended Primary Inductance Converter (SEPIC) because of its intrinsic low input current distortion characteristic making it possible to eliminate the electromagnetic interference (EMI) filter. The power control (PC) stage is performed by a Buck converter using its output current source behavior, suitable for LED application. A 100 W LED driver prototype is implemented resulting in a 6.9% total harmonic distortion (THD) and 30% current ripple on the LED.
本文分析和设计了一种旨在消除或替代电解电容器的发光二极管(LED)驱动器。考虑到电解电容器与led相比寿命较短,该拓扑旨在减少存储电容,并用薄膜电容器代替,从而增加系统寿命。这种降低是基于在输入电流失真和输出电流纹波之间折衷的控制动态设计。功率因数校正(PFC)级基于单端初级电感变换器(SEPIC),其固有的低输入电流畸变特性使其能够消除电磁干扰(EMI)滤波器。功率控制(PC)级由Buck转换器利用其输出电流源行为执行,适用于LED应用。实现了一个100w的LED驱动器原型,导致LED上的总谐波失真(THD)为6.9%,电流纹波为30%。
{"title":"Long-lifetime SEPIC-buck integrated converter for LED lighting application","authors":"M. Cosetin, P. Luz, M. F. da Silva, F. Bisogno, J. M. Alonso, R. D. do Prado","doi":"10.1109/INDUSCON.2012.6451725","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451725","url":null,"abstract":"This paper presents an analysis and design of a Light Emitting Diode (LED) driver aiming to eliminate/substitute the electrolytic capacitors. Considering the low lifetime of electrolytic capacitors compared to LEDs, this topology aims for reducing the storage capacitance and replaces it by a film capacitor, increasing the system lifetime. This reduction is based on designing of the control dynamic with a compromise between the input current distortion and the output current ripple. The power factor correction (PFC) stage is based on a Single Ended Primary Inductance Converter (SEPIC) because of its intrinsic low input current distortion characteristic making it possible to eliminate the electromagnetic interference (EMI) filter. The power control (PC) stage is performed by a Buck converter using its output current source behavior, suitable for LED application. A 100 W LED driver prototype is implemented resulting in a 6.9% total harmonic distortion (THD) and 30% current ripple on the LED.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115494009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Multi-platform education system of frequency inverters 变频器多平台教学系统
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451391
Juliano de O Pacheco, F. Batista, C. Petry
This paper presents the development of a system for didactic teaching of frequency inverters monitored by microcontrollers that can supply a three-phase load up to 1 CV, provide remote access and function in multi-platform, i. e., the control can be implemented by any family of microcontrollers, FPGA's and DSP's. In order to help in the development of the prototype the following steps are performed: theoretical review, prototype design and simulation. The experimental results are presented and discussed, validating the study.
本文介绍了一种由单片机监控的变频器教学教学系统的开发,该系统可以提供高达1cv的三相负载,提供远程访问和多平台功能,即可以由任何系列的单片机,FPGA和DSP实现控制。为了帮助原型的开发,进行了以下步骤:理论回顾,原型设计和仿真。给出了实验结果并进行了讨论,验证了研究结果。
{"title":"Multi-platform education system of frequency inverters","authors":"Juliano de O Pacheco, F. Batista, C. Petry","doi":"10.1109/INDUSCON.2012.6451391","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451391","url":null,"abstract":"This paper presents the development of a system for didactic teaching of frequency inverters monitored by microcontrollers that can supply a three-phase load up to 1 CV, provide remote access and function in multi-platform, i. e., the control can be implemented by any family of microcontrollers, FPGA's and DSP's. In order to help in the development of the prototype the following steps are performed: theoretical review, prototype design and simulation. The experimental results are presented and discussed, validating the study.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"58 9","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114126747","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Comparison of solar panel models for grid integrations studies 并网研究中太阳能电池板模型的比较
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453866
E. M. da S Brito, A. F. Cupertino, L. P. Carlette, D. O. Filho, H. Pereira, P. Ribeiro
Photovoltaic systems are highly dependent on climatic conditions in which they are submitted. The incident solar irradiance and temperature are the main factors impacting on the power generated by a solar panel. This paper presents three different models of a solar panel and compare, through simulations, their accuracies and efficiencies, and also shows the advantages and applications of each model. Simulations for each model connected to the grid were also made through a controlled inverter. This inverter keeps the voltage at the terminals of the panel in a constant value equal to its maximum power point, provided by the manufacturer. In the end, it is possible to see that two of the presented models have almost the same behavior while the third one has some discrepancy.
光伏系统高度依赖于它们所处的气候条件。入射太阳辐照度和温度是影响太阳能电池板发电功率的主要因素。本文介绍了三种不同的太阳能电池板模型,并通过仿真比较了它们的精度和效率,并展示了每种模型的优点和应用。并通过可控逆变器对各模型进行了并网仿真。该逆变器使面板端子处的电压保持在一个恒定值,等于制造商提供的最大功率点。最后,可以看到两个模型具有几乎相同的行为,而第三个模型存在一些差异。
{"title":"Comparison of solar panel models for grid integrations studies","authors":"E. M. da S Brito, A. F. Cupertino, L. P. Carlette, D. O. Filho, H. Pereira, P. Ribeiro","doi":"10.1109/INDUSCON.2012.6453866","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453866","url":null,"abstract":"Photovoltaic systems are highly dependent on climatic conditions in which they are submitted. The incident solar irradiance and temperature are the main factors impacting on the power generated by a solar panel. This paper presents three different models of a solar panel and compare, through simulations, their accuracies and efficiencies, and also shows the advantages and applications of each model. Simulations for each model connected to the grid were also made through a controlled inverter. This inverter keeps the voltage at the terminals of the panel in a constant value equal to its maximum power point, provided by the manufacturer. In the end, it is possible to see that two of the presented models have almost the same behavior while the third one has some discrepancy.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127011077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Common-mode currents in drive systems using PWM inverters: Project of a filter topology for their mitigation 使用PWM逆变器的驱动系统中的共模电流:用于缓解共模电流的滤波器拓扑方案
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6451383
R. S. Araújo, R. A. Rodrigues, H. de Paula, W. P. de Almeida, A. W. F. V. da Silveira
This paper provides a characterization of high-frequency leakage currents in PWM inverters feeding AC motors, contextualized in the analysis of an actual case in which the motor presents premature and recurring failure of its bearings, due to circulation of electric current. From the parameters of an equivalent circuit, in terms of cables, motor and inverter return path, a filter is proposed for mitigation of common-mode currents and related phenomena, characterized by a common-mode transformer. Results from simulations and experimental results show that the proposed transformer represents an advantageous alternative in respect to traditional RC and RLC filters, since, in addition to mitigating common-mode phenomena, the transformer dissipates a negligible amount of power.
本文提供了在PWM逆变器馈电交流电机高频泄漏电流的特征,背景是在实际情况下的分析,其中电机呈现过早和反复失效的轴承,由于电流的循环。从等效电路的参数出发,从电缆、电机和逆变器返回路径三个方面,提出了一种以共模变压器为特征的滤波器,用于缓解共模电流和相关现象。仿真和实验结果表明,所提出的变压器代表了传统RC和RLC滤波器的有利替代方案,因为除了减轻共模现象外,变压器耗散的功率可以忽略不计。
{"title":"Common-mode currents in drive systems using PWM inverters: Project of a filter topology for their mitigation","authors":"R. S. Araújo, R. A. Rodrigues, H. de Paula, W. P. de Almeida, A. W. F. V. da Silveira","doi":"10.1109/INDUSCON.2012.6451383","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6451383","url":null,"abstract":"This paper provides a characterization of high-frequency leakage currents in PWM inverters feeding AC motors, contextualized in the analysis of an actual case in which the motor presents premature and recurring failure of its bearings, due to circulation of electric current. From the parameters of an equivalent circuit, in terms of cables, motor and inverter return path, a filter is proposed for mitigation of common-mode currents and related phenomena, characterized by a common-mode transformer. Results from simulations and experimental results show that the proposed transformer represents an advantageous alternative in respect to traditional RC and RLC filters, since, in addition to mitigating common-mode phenomena, the transformer dissipates a negligible amount of power.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123359144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison between two versions of the discrete wavelet transform for real-time transient detection on synchronous machine terminals 两种离散小波变换在同步机终端实时暂态检测中的比较
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453533
F. Costa, C. M. S. Neto, S. F. Carolino, R. Ribeiro, R. L. Barreto, T. O. A. Rocha, P. Pott
The wavelet transform is a powerful tool for real-time detection of transients on synchronous machine terminals which can be used into the control strategy of a power system stabilizer in order to preserve the power system stability. The main goal of this paper is to identify the faster detection of transients in synchronous generator terminals by using the real-time wavelet coefficients of both the discrete wavelet transform (DWT) and maximal overlapped discrete wavelet transform (MODWT), as well as identify the best mother wavelet for this purpose. Faults with very damped transients were obtained through an experimental system composed of an actual synchronous generator connected to a simplified power system and good results were obtained, showing the efficacy of the wavelet transform for real-time fault detection.
小波变换是实时检测同步电机终端暂态的有力工具,可以将其应用到电力系统稳定器的控制策略中,以保持电力系统的稳定。本文的主要目标是利用离散小波变换(DWT)和最大重叠离散小波变换(MODWT)的实时小波系数来识别同步发电机终端瞬态的更快检测,并确定最佳母小波。通过实际同步发电机与简化电力系统连接的实验系统,获得了瞬态非常阻尼的故障,获得了良好的结果,证明了小波变换在实时故障检测中的有效性。
{"title":"Comparison between two versions of the discrete wavelet transform for real-time transient detection on synchronous machine terminals","authors":"F. Costa, C. M. S. Neto, S. F. Carolino, R. Ribeiro, R. L. Barreto, T. O. A. Rocha, P. Pott","doi":"10.1109/INDUSCON.2012.6453533","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453533","url":null,"abstract":"The wavelet transform is a powerful tool for real-time detection of transients on synchronous machine terminals which can be used into the control strategy of a power system stabilizer in order to preserve the power system stability. The main goal of this paper is to identify the faster detection of transients in synchronous generator terminals by using the real-time wavelet coefficients of both the discrete wavelet transform (DWT) and maximal overlapped discrete wavelet transform (MODWT), as well as identify the best mother wavelet for this purpose. Faults with very damped transients were obtained through an experimental system composed of an actual synchronous generator connected to a simplified power system and good results were obtained, showing the efficacy of the wavelet transform for real-time fault detection.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122443708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Alternatives for voltage control in the scenario of Smart Grids 智能电网场景中电压控制的替代方案
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453554
E. Garcia, P. Pereira, R. Milbradt, L. Canha, A. Abaide
Before the deployment of Smart Grids the quality of voltage is replaced by a new focus, because the regulator is able to improve the activity, the user has access to the value of the voltage in real time and the distributor, in turn, needs to meet the regulatory actions and expectations of its customers. Nowadays in conventional networks the voltage adjustment is performed from the reference voltage set point of itself, as in the scenario of Smart Grids beyond this value is also possible to use the records of voltage of other feeder points. In this new scenario is appropriate to identify alternatives related to voltage control in distribution networks, in this way, the present work presents the forecast of voltage for monitoring points located throughout the electrical system. From the results obtained for the prediction is introduced the concept of intelligent control. The presented methodology considers the taking of proactive actions and proposes the development of a tool to support the operating voltage control in real time.
在部署智能电网之前,电压质量被一个新的焦点所取代,因为调节器能够改善活动,用户可以实时访问电压值,而分销商反过来需要满足其客户的监管行动和期望。目前在传统电网中,电压调整是从自身的参考电压设定点进行的,因为在智能电网的情况下,超过这个值也可以使用其他馈线点的电压记录。在这种新的情况下,确定配电网中与电压控制有关的替代方案是合适的,这样,本工作就提出了整个电力系统监测点的电压预测。根据预测结果,提出了智能控制的概念。提出的方法考虑了采取主动行动,并提出了一种工具的开发,以支持工作电压的实时控制。
{"title":"Alternatives for voltage control in the scenario of Smart Grids","authors":"E. Garcia, P. Pereira, R. Milbradt, L. Canha, A. Abaide","doi":"10.1109/INDUSCON.2012.6453554","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453554","url":null,"abstract":"Before the deployment of Smart Grids the quality of voltage is replaced by a new focus, because the regulator is able to improve the activity, the user has access to the value of the voltage in real time and the distributor, in turn, needs to meet the regulatory actions and expectations of its customers. Nowadays in conventional networks the voltage adjustment is performed from the reference voltage set point of itself, as in the scenario of Smart Grids beyond this value is also possible to use the records of voltage of other feeder points. In this new scenario is appropriate to identify alternatives related to voltage control in distribution networks, in this way, the present work presents the forecast of voltage for monitoring points located throughout the electrical system. From the results obtained for the prediction is introduced the concept of intelligent control. The presented methodology considers the taking of proactive actions and proposes the development of a tool to support the operating voltage control in real time.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132792196","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ZVS bidirectional isolated three-phase DC-DC converter with dual phase-shift and variable duty cycle ZVS双向隔离三相DC-DC变换器,双相移和可变占空比
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453820
H. M. de Oliveira Filho, D. Oliveira, C. E. de A e Silva, F. L. Tofoli
This paper presents the analysis, design, and simulation results for a ZVS bidirectional isolated three-phase DC-DC converter with dual phase-shift and variable duty cycle. The topology uses three single H-bridges in the primary side and a three-phase inverter in the secondary side. The isolation is ensured by using three single-phase transformers connected in open delta-wye configuration. Variation of both phase shift angles between single H-bridge legs and/or primary and secondary side allows the power delivery control. This additional flexibility allows the system to maintain a low reactive power flow. The variable duty cycle is used to ensure a constant voltage bus and ZVS soft switching operation. A detailed analysis is presented considering a model based on fundamental components. Simulations for converter are performed to validate the model used.
本文介绍了一种双相移变占空比ZVS双向隔离三相DC-DC变换器的分析、设计和仿真结果。该拓扑在主侧使用三个单h桥,在次侧使用一个三相逆变器。隔离是通过使用三个单相变压器连接在开放三角型配置来确保的。单个h桥支腿和/或主侧和次侧之间的相移角变化允许功率传输控制。这种额外的灵活性使系统能够保持低无功功率流。可变占空比用于确保恒压母线和ZVS软开关操作。考虑到基于基本组件的模型,给出了详细的分析。对变换器进行了仿真,验证了模型的有效性。
{"title":"ZVS bidirectional isolated three-phase DC-DC converter with dual phase-shift and variable duty cycle","authors":"H. M. de Oliveira Filho, D. Oliveira, C. E. de A e Silva, F. L. Tofoli","doi":"10.1109/INDUSCON.2012.6453820","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453820","url":null,"abstract":"This paper presents the analysis, design, and simulation results for a ZVS bidirectional isolated three-phase DC-DC converter with dual phase-shift and variable duty cycle. The topology uses three single H-bridges in the primary side and a three-phase inverter in the secondary side. The isolation is ensured by using three single-phase transformers connected in open delta-wye configuration. Variation of both phase shift angles between single H-bridge legs and/or primary and secondary side allows the power delivery control. This additional flexibility allows the system to maintain a low reactive power flow. The variable duty cycle is used to ensure a constant voltage bus and ZVS soft switching operation. A detailed analysis is presented considering a model based on fundamental components. Simulations for converter are performed to validate the model used.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115029110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Variable speed wind turbine using the squirrel cage induction generator with reduced converter power rating for stand-alone energy systems 变速风力涡轮机使用鼠笼感应发电机与降低转换器额定功率的独立能源系统
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6453324
J. G. Trapp, F. Farret, F. T. Fernandes, L. C. Correa, C. M. Wechenfelder
This paper presents a new configuration for a wind energy conversion system (WECS) with variable speed, using a squirrel cage induction generator (SCIG) for stand-alone energy system applications. The Proposed configuration utilizes converters with reduced power rating, operates with MPPT to maximum wind energy extraction, uses battery bank for energy storage and can operate with non-linear and unbalanced loads. Energy storage characteristic is desirable for wind energy conversion systems isolated from the mains since an energy interruption does not stop of the entire system. Also, the power rating of the converters is reduced compared to the generator and load power rating due to the low power requirements of the power converters to SCIG excitation control and to supply the load. It is presented also the whole proposed WECS and the system operation modes according the turbine speed. It is presented also the whole proposed system and the system operation modes according the turbine speed. The simulation of the proposed WECS is performed in conjunction with the dynamic wind turbine model of 1 kW and the results confirm the effectiveness to supply unbalanced and non-linear loads, the converters power rating reduction and operation with variable turbine speed. Simulation results show the effectiveness of the system to supply unbalanced and non-linear stand alone loads.
本文提出了一种采用鼠笼式感应发电机(SCIG)的变速风能转换系统(WECS)的新配置,用于单机能源系统。建议的配置利用降低额定功率的转换器,与MPPT一起运行以最大限度地提取风能,使用电池组进行能量存储,并且可以在非线性和不平衡负载下运行。由于能量中断不会停止整个系统,因此与市电隔离的风能转换系统需要具有能量存储特性。此外,由于功率转换器对SCIG励磁控制和供电负载的功率要求较低,因此变流器的额定功率与发电机和负载额定功率相比有所降低。给出了整个系统的设计方案,以及系统在不同转速下的运行模式。并介绍了整个系统和系统在不同水轮机转速下的运行模式。结合1 kW动态风力机模型对该系统进行了仿真,验证了该系统在提供不平衡和非线性负荷、降低变流器额定功率和变转速下运行的有效性。仿真结果表明,该系统对不平衡和非线性独立负载的供电是有效的。
{"title":"Variable speed wind turbine using the squirrel cage induction generator with reduced converter power rating for stand-alone energy systems","authors":"J. G. Trapp, F. Farret, F. T. Fernandes, L. C. Correa, C. M. Wechenfelder","doi":"10.1109/INDUSCON.2012.6453324","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6453324","url":null,"abstract":"This paper presents a new configuration for a wind energy conversion system (WECS) with variable speed, using a squirrel cage induction generator (SCIG) for stand-alone energy system applications. The Proposed configuration utilizes converters with reduced power rating, operates with MPPT to maximum wind energy extraction, uses battery bank for energy storage and can operate with non-linear and unbalanced loads. Energy storage characteristic is desirable for wind energy conversion systems isolated from the mains since an energy interruption does not stop of the entire system. Also, the power rating of the converters is reduced compared to the generator and load power rating due to the low power requirements of the power converters to SCIG excitation control and to supply the load. It is presented also the whole proposed WECS and the system operation modes according the turbine speed. It is presented also the whole proposed system and the system operation modes according the turbine speed. The simulation of the proposed WECS is performed in conjunction with the dynamic wind turbine model of 1 kW and the results confirm the effectiveness to supply unbalanced and non-linear loads, the converters power rating reduction and operation with variable turbine speed. Simulation results show the effectiveness of the system to supply unbalanced and non-linear stand alone loads.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129890271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Boost clamped integrated DC/DC topologies with high step-up voltage gain 具有高升压增益的升压箝位集成DC/DC拓扑结构
Pub Date : 2012-11-01 DOI: 10.1109/INDUSCON.2012.6452939
J. Dreher, F. Marangoni, J. Ortiz, C. Rech, M. L. da S. Martins, H. T. Camara, L. D. Flora
High step-up voltage gain in DC/DC converters can be achieved by means of the voltage conversion ability of transformers and coupled inductors. Aiming to avoid the problems caused by the leakage inductance of the magnetics, this paper proposes the use of passive clamping circuits. The boost clamping is integrated with a set of isolated topologies forming a family of converters, named Integrated Boost-Isolated DC/DC converters. The method to generate such topologies is presented and discussed. The methodology is also briefly discussed to the buckboost converter. To further analyze the reliability of the method and the characteristics of the derived converters, the two Integrated Boost-Flyback converters have been evaluated. Experimental results obtained from laboratory prototypes proved the reliability of the integration methodology and also pointed out the Series Integrated Boost-Flyback converter as the strongest candidate for high voltage gain applications.
利用变压器和耦合电感的电压转换能力,可以实现DC/DC变换器的高升压增益。为了避免磁体漏感带来的问题,本文提出采用无源箝位电路。升压钳位集成了一组隔离拓扑,形成了一系列转换器,称为集成升压隔离DC/DC转换器。提出并讨论了生成这种拓扑的方法。本文还对buck - boost变换器的方法进行了简要讨论。为了进一步分析该方法的可靠性和衍生变换器的特性,对两种集成升压-反激变换器进行了评估。从实验室样机中获得的实验结果证明了集成方法的可靠性,并指出串联集成升压-反激变换器是高电压增益应用的最强候选。
{"title":"Boost clamped integrated DC/DC topologies with high step-up voltage gain","authors":"J. Dreher, F. Marangoni, J. Ortiz, C. Rech, M. L. da S. Martins, H. T. Camara, L. D. Flora","doi":"10.1109/INDUSCON.2012.6452939","DOIUrl":"https://doi.org/10.1109/INDUSCON.2012.6452939","url":null,"abstract":"High step-up voltage gain in DC/DC converters can be achieved by means of the voltage conversion ability of transformers and coupled inductors. Aiming to avoid the problems caused by the leakage inductance of the magnetics, this paper proposes the use of passive clamping circuits. The boost clamping is integrated with a set of isolated topologies forming a family of converters, named Integrated Boost-Isolated DC/DC converters. The method to generate such topologies is presented and discussed. The methodology is also briefly discussed to the buckboost converter. To further analyze the reliability of the method and the characteristics of the derived converters, the two Integrated Boost-Flyback converters have been evaluated. Experimental results obtained from laboratory prototypes proved the reliability of the integration methodology and also pointed out the Series Integrated Boost-Flyback converter as the strongest candidate for high voltage gain applications.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128936785","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
2012 10th IEEE/IAS International Conference on Industry Applications
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1