Adriana Bona Matos, Christine D Wu, Wei Li, Ana K Bedran-Russo
Purpose: To investigate whether interfacial enzymatic activity and adhesion receptiveness of artificial caries-affected dentin (ACAD) simulate those of natural caries-affected dentin (NCAD).
Materials and methods: Thirty dentin specimens were prepared from human molars to determine interfacial gelatinolytic activity using in situ zymography and adhesion experiments (micropermeability and bond strength [µTBS]). Groups were formed according to the type of dentin: artificial caries-affected dentin (ACAD), natural caries-affected dentin (NCAD), or sound dentin. ACAD was produced by incubating dentin with Streptococcus mutans in a chemically defined medium (CDM) with 1% sucrose for 7 days at 37°C under anaerobic conditions. CDM was replaced daily, and the sterility as well as the pH of the culture was monitored. Adhesion experiments employed Single Bond Universal (3M Oral Care) in self-etch mode. Data were individually processed and analyzed using ANOVA and post-hoc tests (α = 0.05).
Results: The enzymatic activity of ACAD was similar to that of sound dentin, but was lower than that of NCAD, which elicited the highest activity (p < 0.05). Interfacial micropermeability intensity at the hybrid layer or in underlying dentin (5 µm below the interface) was similar in all types of dentin (p > 0.05). On the other hand, substrate permeability was higher for NCAD than for ACAD. The highest sealing ability was detected in sound dentin. Bond strengths to ACAD were higher than to NCAD. However, the highest µTBS was observed in sound dentin (p < 0.05).
Conclusion: Artificial caries-affected dentin simulated neither the gelatinolytic activity nor bonding receptiveness of natural caries-affected dentin.
目的:观察人工龋损牙本质(ACAD)的界面酶活性和粘附接受性是否与天然龋损牙本质(NCAD)相似。材料和方法:采用原位酶谱法和黏附实验(微渗透性和黏附强度[µTBS])测定30例人磨牙牙本质样品的界面胶溶活性。根据牙本质的类型分为人工牙本质(ACAD)、天然牙本质(NCAD)和健全牙本质。ACAD是通过在含有1%蔗糖的化学定义培养基(CDM)中,在37℃厌氧条件下,将牙本质与变形链球菌一起培养7天而产生的。每天更换CDM,并监测培养物的无菌性和pH值。粘附实验采用3M Oral Care (Single Bond Universal)自蚀刻模式。采用方差分析和事后检验对数据进行单独处理和分析(α = 0.05)。结果:ACAD酶活性与健全牙本质相近,但低于NCAD酶活性,以NCAD酶活性最高(p < 0.05)。混合层和下垫牙本质(界面以下5µm)的界面微渗透强度在各类型牙本质中相似(p > 0.05)。另一方面,NCAD的基质渗透性高于ACAD,在健全的牙本质中检测到最高的密封能力。与ACAD的结合强度高于与NCAD的结合强度。而健全牙本质的µTBS最高(p < 0.05)。结论:人工牙本质既不能模拟天然牙本质的胶溶活性,也不能模拟天然牙本质的结合接受能力。
{"title":"Gelatinolytic Activity and Adhesion Studies of Artificial Caries-affected Dentin do not Simulate Natural Caries.","authors":"Adriana Bona Matos, Christine D Wu, Wei Li, Ana K Bedran-Russo","doi":"10.3290/j.jad.a44873","DOIUrl":"https://doi.org/10.3290/j.jad.a44873","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether interfacial enzymatic activity and adhesion receptiveness of artificial caries-affected dentin (ACAD) simulate those of natural caries-affected dentin (NCAD).</p><p><strong>Materials and methods: </strong>Thirty dentin specimens were prepared from human molars to determine interfacial gelatinolytic activity using in situ zymography and adhesion experiments (micropermeability and bond strength [µTBS]). Groups were formed according to the type of dentin: artificial caries-affected dentin (ACAD), natural caries-affected dentin (NCAD), or sound dentin. ACAD was produced by incubating dentin with Streptococcus mutans in a chemically defined medium (CDM) with 1% sucrose for 7 days at 37°C under anaerobic conditions. CDM was replaced daily, and the sterility as well as the pH of the culture was monitored. Adhesion experiments employed Single Bond Universal (3M Oral Care) in self-etch mode. Data were individually processed and analyzed using ANOVA and post-hoc tests (α = 0.05).</p><p><strong>Results: </strong>The enzymatic activity of ACAD was similar to that of sound dentin, but was lower than that of NCAD, which elicited the highest activity (p < 0.05). Interfacial micropermeability intensity at the hybrid layer or in underlying dentin (5 µm below the interface) was similar in all types of dentin (p > 0.05). On the other hand, substrate permeability was higher for NCAD than for ACAD. The highest sealing ability was detected in sound dentin. Bond strengths to ACAD were higher than to NCAD. However, the highest µTBS was observed in sound dentin (p < 0.05).</p><p><strong>Conclusion: </strong>Artificial caries-affected dentin simulated neither the gelatinolytic activity nor bonding receptiveness of natural caries-affected dentin.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 4","pages":"415-420"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3290/j.jad.a44873","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38160618","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose: This randomized, split-mouth clinical study evaluated the marginal quality of direct class-I and class-II restorations made of microhybrid composite that were applied using two polymerization protocols and two marginal evaluation criteria.
Materials and methods: A total of 50 patients (mean age: 33 years) received 100 direct class-I or class-II restorations in premolars or molars. Three calibrated operators made the restorations. After conditioning the tooth with 2-step etch-and-rinse adhesive, restorations were made incrementally using microhybrid composite. Each layer was polymerized using a polymerization device operated either in regular mode (600-650 mW/cm2 for 20 s) (RM) or high-power (1200-1300 mW/cm2 for 10 s) mode (HPM). Two independent, calibrated operators evaluated the restorations 1 week (baseline) and 6 months after restoration placement, and thereafter annually up to 10 years using modified USPHS and SQUACE criteria. Data were analyzed using the Mann-Whitney U-test (α = 0.05).
Results: Alpha scores (USPHS) for marginal adaptation (76% and 74% for RM and HPM, respectively) and marginal discoloration (70% and 72%, for RM and HPM, respectively) did not show significant differences between the two polymerization protocols (p > 0.05). Alpha scores (SQUACE) for marginal adaptation (78% and 74% for RM and HPM, respectively) and marginal discoloration (70% for both RM and HPM) were also not significantly different at the 10-year year follow-up (p > 0.05).
Conclusion: Regular and high-power polymerization protocols had no influence on the stability of marginal quality of the microhybrid composite tested up to 10 years. Both modified USPHS and SQUACE criteria confirmed that regardless of the polymerization mode, marginal quality of the restorations deteriorated significantly compared to baseline (p < 0.05).
{"title":"Clinical Performance of Posterior Microhybrid Resin Composite Restorations Applied Using Regular and High-Power Mode Polymerization Protocols According to USPHS and SQUACE Criteria: 10-Year Randomized Controlled Split-Mouth Trial.","authors":"Antonio Cerutti, Nicola Barabanti, Mutlu Özcan","doi":"10.3290/j.jad.a44865","DOIUrl":"https://doi.org/10.3290/j.jad.a44865","url":null,"abstract":"<p><strong>Purpose: </strong>This randomized, split-mouth clinical study evaluated the marginal quality of direct class-I and class-II restorations made of microhybrid composite that were applied using two polymerization protocols and two marginal evaluation criteria.</p><p><strong>Materials and methods: </strong>A total of 50 patients (mean age: 33 years) received 100 direct class-I or class-II restorations in premolars or molars. Three calibrated operators made the restorations. After conditioning the tooth with 2-step etch-and-rinse adhesive, restorations were made incrementally using microhybrid composite. Each layer was polymerized using a polymerization device operated either in regular mode (600-650 mW/cm2 for 20 s) (RM) or high-power (1200-1300 mW/cm2 for 10 s) mode (HPM). Two independent, calibrated operators evaluated the restorations 1 week (baseline) and 6 months after restoration placement, and thereafter annually up to 10 years using modified USPHS and SQUACE criteria. Data were analyzed using the Mann-Whitney U-test (α = 0.05).</p><p><strong>Results: </strong>Alpha scores (USPHS) for marginal adaptation (76% and 74% for RM and HPM, respectively) and marginal discoloration (70% and 72%, for RM and HPM, respectively) did not show significant differences between the two polymerization protocols (p > 0.05). Alpha scores (SQUACE) for marginal adaptation (78% and 74% for RM and HPM, respectively) and marginal discoloration (70% for both RM and HPM) were also not significantly different at the 10-year year follow-up (p > 0.05).</p><p><strong>Conclusion: </strong>Regular and high-power polymerization protocols had no influence on the stability of marginal quality of the microhybrid composite tested up to 10 years. Both modified USPHS and SQUACE criteria confirmed that regardless of the polymerization mode, marginal quality of the restorations deteriorated significantly compared to baseline (p < 0.05).</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 4","pages":"343-351"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3290/j.jad.a44865","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38160197","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Maurício Bottene Guarda, Paolo Tulio Di Nizo, Gabriel Flores Abuna, Anderson Catelan, Mário Alexandre Coelho Sinhoreti, Rafael Pino Vitti
Purpose: To assess the effect of the application of different electric currents on dentin bonding and resin infiltration of self-etching and etch-and-rinse adhesives.
Materials and methods: Two hundred four sound third molars were selected and divided in groups according to the adhesive (self-etch [CSE, Clearfil SE Bond, Kuraray Noritake], universal [SBU, Single Bond Universal, 3M Oral Care], and etch-and-rinse [SB2, Adper Single Bond 2 (SB2), 3M Oral Care]) and electrical current used (0, 5, 10, 15, 20, 25, 30, and 35 μA). Light curing was performed for 10 s with an LED-curing unit at 1000 mW/cm2. Composite blocks were constructed of nanofilled composite in increments of 2 mm, which were light cured for 20 s. Specimens were sectioned into sticks with a cross-sectional area of ~1 mm2 and stored in distilled water at 37°C for 24 h. Microtensile bond strength (μTBS) testing (n = 8) was performed using a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The bonding quality (n = 2) of adhesives applied with or without 35-μA electric current was evaluated using confocal laser scanning microscopy. Bond strengths were analyzed with two-way ANOVA and Tukey's test (α = 0.05).
Results: CSE presented the highest μTBS for all electrical currents tested. For CSE and SBU, electrical currents from 0-20 μA showed the lowest μTBS. Electrical currents from 0-10 and 20-25 μA yielded the lowest μTBS for SB2. CSE and SB2 applied under 35 μA showed a greater number of resin tags in dentin tubules. Fluorescein penetration into the hybrid layer was found for SBU applied without electric current.
Conclusion: The application of adhesives using 35-μA electric current improved the bond strength and quality of the adhesive interface.
{"title":"Effect of Electric Current-assisted Application of Adhesives on their Bond Strength and Quality.","authors":"Maurício Bottene Guarda, Paolo Tulio Di Nizo, Gabriel Flores Abuna, Anderson Catelan, Mário Alexandre Coelho Sinhoreti, Rafael Pino Vitti","doi":"10.3290/j.jad.a44870","DOIUrl":"https://doi.org/10.3290/j.jad.a44870","url":null,"abstract":"<p><strong>Purpose: </strong>To assess the effect of the application of different electric currents on dentin bonding and resin infiltration of self-etching and etch-and-rinse adhesives.</p><p><strong>Materials and methods: </strong>Two hundred four sound third molars were selected and divided in groups according to the adhesive (self-etch [CSE, Clearfil SE Bond, Kuraray Noritake], universal [SBU, Single Bond Universal, 3M Oral Care], and etch-and-rinse [SB2, Adper Single Bond 2 (SB2), 3M Oral Care]) and electrical current used (0, 5, 10, 15, 20, 25, 30, and 35 μA). Light curing was performed for 10 s with an LED-curing unit at 1000 mW/cm2. Composite blocks were constructed of nanofilled composite in increments of 2 mm, which were light cured for 20 s. Specimens were sectioned into sticks with a cross-sectional area of ~1 mm2 and stored in distilled water at 37°C for 24 h. Microtensile bond strength (μTBS) testing (n = 8) was performed using a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The bonding quality (n = 2) of adhesives applied with or without 35-μA electric current was evaluated using confocal laser scanning microscopy. Bond strengths were analyzed with two-way ANOVA and Tukey's test (α = 0.05).</p><p><strong>Results: </strong>CSE presented the highest μTBS for all electrical currents tested. For CSE and SBU, electrical currents from 0-20 μA showed the lowest μTBS. Electrical currents from 0-10 and 20-25 μA yielded the lowest μTBS for SB2. CSE and SB2 applied under 35 μA showed a greater number of resin tags in dentin tubules. Fluorescein penetration into the hybrid layer was found for SBU applied without electric current.</p><p><strong>Conclusion: </strong>The application of adhesives using 35-μA electric current improved the bond strength and quality of the adhesive interface.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 4","pages":"393-398"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3290/j.jad.a44870","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38160615","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mark A Latta, Akimasa Tsujimoto, Toshiki Takamizawa, Wayne W Barkmeier
Purpose: To use shear bond strength (SBS) and shear fatigue strength (SFS) testing to determine the durability of adhesion of self-adhesive restorative materials compared to composite resin bonded with a universal adhesive.
Materials and methods: A universal adhesive, Prime & Bond Active, was used in self-etch mode to bond Z-100 composite resin to enamel and dentin. Three commercially available restorative materials and one experimental material with self-adhesive properties, Activa (A), Fuji II LC(F), and Equia Forte (E) and ASAR-MP4 (S) were also bonded to enamel and dentin. The SBS and SFS were determined for all materials. A staircase method was used to determine the SFS with 10 Hz frequency for 50,000 cycles or until failure occurred.
Results: On enamel, S generated similar values to the adhesive/composite materials and higher values than F, E, and A. On dentin, the composite/universal adhesive showed significantly higher SBS and SFS than the self-adhesive materials. S, F, and E generated higher values than A on dentin.
Conclusion: SBS and SFS values to enamel were similar for all materials tested except Activa which generated lower enamel values. On dentin surfaces, the self-adhesive materials generated similar SBS and SFS, with the exception of Activa. Those values were lower than that generated with composite resin and a universal adhesive.
目的:采用剪切粘接强度(SBS)和剪切疲劳强度(SFS)试验,比较自粘修复材料与复合树脂与通用胶粘剂的粘接耐久性。材料和方法:使用万能胶粘剂Prime & Bond Active,以自蚀刻方式将Z-100复合树脂粘接在牙釉质和牙本质上。三种市售修复材料和一种具有自粘性能的实验材料Activa (A)、Fuji II LC(F)、Equia Forte (E)和ASAR-MP4 (S)也与牙釉质和牙本质结合。测定了所有材料的SBS和SFS。采用阶梯法以10 Hz频率测定5万次循环或直至故障发生的SFS。结果:在牙釉质上,S值与粘接剂/复合材料相近,高于F、E和a。在牙本质上,复合/通用粘接剂的SBS和SFS值明显高于自粘材料。S、F、E对牙本质的影响大于A。结论:除Activa对牙釉质产生较低的牙釉质值外,所有材料对牙釉质的SBS和SFS值相似。在牙本质表面,除Activa外,自粘材料产生的SBS和SFS相似。这些值低于复合树脂和通用粘合剂产生的值。
{"title":"Enamel and Dentin Bond Durability of Self-Adhesive Restorative Materials.","authors":"Mark A Latta, Akimasa Tsujimoto, Toshiki Takamizawa, Wayne W Barkmeier","doi":"10.3290/j.jad.a43996","DOIUrl":"https://doi.org/10.3290/j.jad.a43996","url":null,"abstract":"<p><strong>Purpose: </strong>To use shear bond strength (SBS) and shear fatigue strength (SFS) testing to determine the durability of adhesion of self-adhesive restorative materials compared to composite resin bonded with a universal adhesive.</p><p><strong>Materials and methods: </strong>A universal adhesive, Prime & Bond Active, was used in self-etch mode to bond Z-100 composite resin to enamel and dentin. Three commercially available restorative materials and one experimental material with self-adhesive properties, Activa (A), Fuji II LC(F), and Equia Forte (E) and ASAR-MP4 (S) were also bonded to enamel and dentin. The SBS and SFS were determined for all materials. A staircase method was used to determine the SFS with 10 Hz frequency for 50,000 cycles or until failure occurred.</p><p><strong>Results: </strong>On enamel, S generated similar values to the adhesive/composite materials and higher values than F, E, and A. On dentin, the composite/universal adhesive showed significantly higher SBS and SFS than the self-adhesive materials. S, F, and E generated higher values than A on dentin.</p><p><strong>Conclusion: </strong>SBS and SFS values to enamel were similar for all materials tested except Activa which generated lower enamel values. On dentin surfaces, the self-adhesive materials generated similar SBS and SFS, with the exception of Activa. Those values were lower than that generated with composite resin and a universal adhesive.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 1","pages":"99-105"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3290/j.jad.a43996","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37618992","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose: The management of complicated crown-root fractures is challenging for endodontic restoration. The present case describes a patient who sustained trauma to the maxillary right central incisor.
Materials and methods: Clinical and radiographic examination showed a complicated crown-root fracture and incomplete root development with periapical radiolucency and inadequate endodontic treatment with overfilling. Orthograde retreatment with MTA apical closure combined with a microsurgical approach to remove of extruded material was performed. Coronal sealing was accomplished with a direct adhesive restoration and marginal relocation.
Results: A 5-year follow-up showed complete healing of the periapical lesion and correct preservation of function and esthetic parameters.
Conclusion: A modern minimally invasive treatment protocol allows the maximum conservation of residual dental tissues.
{"title":"Combined Endo-restorative Treatment of a Traumatized Central Incisor: A Five-year Follow-up.","authors":"Mario Alovisi, Riccardo Michelotto Tempesta, Allegra Comba, Damiano Pasqualini, Nicola Scotti","doi":"10.3290/j.jad.a44548","DOIUrl":"https://doi.org/10.3290/j.jad.a44548","url":null,"abstract":"<p><strong>Purpose: </strong>The management of complicated crown-root fractures is challenging for endodontic restoration. The present case describes a patient who sustained trauma to the maxillary right central incisor.</p><p><strong>Materials and methods: </strong>Clinical and radiographic examination showed a complicated crown-root fracture and incomplete root development with periapical radiolucency and inadequate endodontic treatment with overfilling. Orthograde retreatment with MTA apical closure combined with a microsurgical approach to remove of extruded material was performed. Coronal sealing was accomplished with a direct adhesive restoration and marginal relocation.</p><p><strong>Results: </strong>A 5-year follow-up showed complete healing of the periapical lesion and correct preservation of function and esthetic parameters.</p><p><strong>Conclusion: </strong>A modern minimally invasive treatment protocol allows the maximum conservation of residual dental tissues.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 3","pages":"249-254"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37958658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose: This study evaluated the effect of an aromatic silane compound and acidic functional monomer on the bond strength of fused quartz. Materials and Methods: A total of 264 disk specimens were fabricated from fused quartz for shear bond testing. Two silane compounds were used: 3-(trimethoxysilyl)propyl methacrylate (3-TMSPMA) and 3-(4-methacryloyloxyphenyl) propyltrimethoxysilane (3-MPPTS). As acidic functional monomers, 4-methacryloyloxyethyl trimellitate (4-MET) and 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) were used. The disks were primed with one of each silane compound with or without the acidic functional monomer of the same molarity. The specimens were bonded with a tri-n-butylborane (TBB) initiated luting material. The shear bond strength was determined before and after 10,000 thermocycles. Bond strength was statistically evaluated with Kruskal-Wallis, Mann-Whitney U-, and Steel- Dwass tests. To test dye penetration, the specimens were immersed in 0.5 wt% fuchsin solution for 24 h after priming with each condition, bonding, and 10,000 thermocycles. The dye penetration area was determined by observing the backside of the bonded specimen with an optical microscope. The relationship between the shear bond strength and dye penetration ratio was analyzed with Spearman’s rank correlation test. Results: The highest post-thermocycling bond strengths in the 1 mol% and 2 mol% groups were 3-TMSPMA + 10- MDP and 3-MPPTS + 10-MDP. Spearman’s rank correlation coefficient between shear bond strength and dye penetration area was γ = -0.7519, indicating a strong negative correlation. Conclusion: The surface treatments of 3-TMSPMA and 3-MPPTS combined with 10-MDP yielded higher bond strength after 10,000 thermocycles than those combined with 4-MET, despite the similarity in molarity. The shear bond strength was negatively correlated with the dye penetration area.
{"title":"Bonding of Fused Quartz with an Aromatic Silane Compound and Acidic Functional Monomers with a Tri-n-butylborane Initiated Resin.","authors":"Tomoyo Okazaki, Hiroyasu Koizumi, Haruto Hiraba, Akihisa Kodaira, Takayuki Yoneyama, Hideo Matsumura","doi":"10.3290/j.jad.a45517","DOIUrl":"https://doi.org/10.3290/j.jad.a45517","url":null,"abstract":"<p><p>Purpose: This study evaluated the effect of an aromatic silane compound and acidic functional monomer on the bond strength of fused quartz. \u0000Materials and Methods: A total of 264 disk specimens were fabricated from fused quartz for shear bond testing. Two silane compounds were used: 3-(trimethoxysilyl)propyl methacrylate (3-TMSPMA) and 3-(4-methacryloyloxyphenyl) propyltrimethoxysilane (3-MPPTS). As acidic functional monomers, 4-methacryloyloxyethyl trimellitate (4-MET) and 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) were used. The disks were primed with one of each silane compound with or without the acidic functional monomer of the same molarity. The specimens were bonded with a tri-n-butylborane (TBB) initiated luting material. The shear bond strength was determined before and after 10,000 thermocycles. Bond strength was statistically evaluated with Kruskal-Wallis, Mann-Whitney U-, and Steel- Dwass tests. To test dye penetration, the specimens were immersed in 0.5 wt% fuchsin solution for 24 h after priming with each condition, bonding, and 10,000 thermocycles. The dye penetration area was determined by observing the backside of the bonded specimen with an optical microscope. The relationship between the shear bond strength and dye penetration ratio was analyzed with Spearman’s rank correlation test. \u0000Results: The highest post-thermocycling bond strengths in the 1 mol% and 2 mol% groups were 3-TMSPMA + 10- MDP and 3-MPPTS + 10-MDP. Spearman’s rank correlation coefficient between shear bond strength and dye penetration area was γ = -0.7519, indicating a strong negative correlation. \u0000Conclusion: The surface treatments of 3-TMSPMA and 3-MPPTS combined with 10-MDP yielded higher bond strength after 10,000 thermocycles than those combined with 4-MET, despite the similarity in molarity. The shear bond strength was negatively correlated with the dye penetration area.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 6","pages":"615-624"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38861530","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Cornelia Frese, Theresa Wohlrab, Sebastian Soliman, Britta Hahn, Christopher Büsch, Arian Babai, Gabriel Krastl, Diana Wolff
Purpose: The purpose of this multicenter study was to evaluate the survival and quality outcome of direct composite buildups in the anterior dentition based on representative sample sizes. Materials and Methods: At three university clinics in Germany, the survival and quality outcome of n = 667 direct composite buildups performed between 2001 and 2012 was evaluated in n = 198 participants. Survival outcomes were categorized as failure (F), survival (SR), or successful (S). Restorations still in place and without failure prior to follow-up (n = 567) were rated using modified USPHS/FDI criteria to obtain the quality outcome. Detailed failure analysis was done by means of Cox regression models. Results: The restricted mean for overall survival was 15.5 years. N = 576 restorations were classified as successful (S), n = 81 survived with repair (SR) and n = 8 failed (F). Two restorations were removed due to iatrogenic interventions. Overall survival rates after 2, 10, and 15 years were 98.8% (CI: 97.6 and 99.4), 91.7% (CI: 89.0 and 93.8), and 77.6% (CI: 72.2 and 82.2), respectively. Functional survival rates were 100.0%, 98.9% (CI: 97.5 and 99.5), and 98.5% (CI: 96.7 and 99.3), respectively. Clinical quality was rated as excellent or good for most restorations. The dominant failure mode was chipping; however, regression analysis did not detect any influence of the evaluated parameters “enlargement range,” “position in the jaw,” or “tooth type” on failure. Conclusion: This multicenter study represents the first of its type including clinical survival and quality data on 576 direct anterior composite buildups over a restricted mean follow-up of 15.5 years in a relatively large group of participants. In particular, functional survival was outstanding due to the clinical reliability of this treatment option, while simultaneously providing flexibility, reparability, and minimal invasiveness.
{"title":"A Multicenter Trial on the Long-term Performance of Direct Composite Buildups in the Anterior Dentition - Survival and Quality Outcome.","authors":"Cornelia Frese, Theresa Wohlrab, Sebastian Soliman, Britta Hahn, Christopher Büsch, Arian Babai, Gabriel Krastl, Diana Wolff","doi":"10.3290/j.jad.a45514","DOIUrl":"https://doi.org/10.3290/j.jad.a45514","url":null,"abstract":"<p><p>Purpose: The purpose of this multicenter study was to evaluate the survival and quality outcome of direct composite buildups in the anterior dentition based on representative sample sizes. \u0000Materials and Methods: At three university clinics in Germany, the survival and quality outcome of n = 667 direct composite buildups performed between 2001 and 2012 was evaluated in n = 198 participants. Survival outcomes were categorized as failure (F), survival (SR), or successful (S). Restorations still in place and without failure prior to follow-up (n = 567) were rated using modified USPHS/FDI criteria to obtain the quality outcome. Detailed failure analysis was done by means of Cox regression models. \u0000Results: The restricted mean for overall survival was 15.5 years. N = 576 restorations were classified as successful (S), n = 81 survived with repair (SR) and n = 8 failed (F). Two restorations were removed due to iatrogenic interventions. Overall survival rates after 2, 10, and 15 years were 98.8% (CI: 97.6 and 99.4), 91.7% (CI: 89.0 and 93.8), and 77.6% (CI: 72.2 and 82.2), respectively. Functional survival rates were 100.0%, 98.9% (CI: 97.5 and 99.5), and 98.5% (CI: 96.7 and 99.3), respectively. Clinical quality was rated as excellent or good for most restorations. The dominant failure mode was chipping; however, regression analysis did not detect any influence of the evaluated parameters “enlargement range,” “position in the jaw,” or “tooth type” on failure. \u0000Conclusion: This multicenter study represents the first of its type including clinical survival and quality data on 576 direct anterior composite buildups over a restricted mean follow-up of 15.5 years in a relatively large group of participants. In particular, functional survival was outstanding due to the clinical reliability of this treatment option, while simultaneously providing flexibility, reparability, and minimal invasiveness.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 6","pages":"573-580"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38861526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Fabiana Suelen Figuerêdo de Siqueira, Leslee Angheloris Rivadeneira Morales, Martha Cecilia Perez Granja, Bruna de Oliveira de Melo, Valerio Monteiro-Neto, Alessandra Reis, Andres Felipe Millan Cardenas, Alessandro D Loguercio
Purpose: To evaluate 1. the microtensile bond strength (µTBS) and in situ degree of conversion (DC) of adhesives applied using two bonding strategies after silver diamine fluoride (diamine) application on carious dentinal lesions, and 2. dentin etching patterns using SEM and energy dispersive x-ray spectroscopy.
Materials and methods: Human molars were randomly divided into 12 experimental groups according to: 1. application of a silver diamine fluoride solution (carious dentinal lesion without silver diamine fluoride treatment [control], with 12% silver diamine fluoride [diamine 12%] or 38% silver diamine fluoride [diamine 38%]); 2. adhesives (Clearfil Universal Bond Quick [CUQ] and Scotchbond Universal [SBU]); 3. adhesive strategy (etch-and-rinse [ER] and self-etch [SE]). After restoration, the specimens were sectioned and submitted to µTBS testing. Sticks from each tooth were used for DC evaluation. To examine the changes induced by diamine before and after phosphoric acid treatment, SEM/EDX analysis was performed. Data from the µTBS and DC tests were analyzed using three-way ANOVA and Tukey's test (α = 0.05).
Results: Both concentrations of diamine resulted in a statistically significantly higher mean µTBS compared to the control (p < 0.0001). Diamine 38% showed a statistically significantly higher mean µTBS for both adhesives in SE mode compared to diamine 12% (p < 0.0001). The application of diamine to carious dentinal lesions did not significantly influence the mean DC values for either adhesive (p = 0.72). SBU showed a higher mean DC compared to CUQ (p = 0.03). After diamine treatment, there was an increase in the Ca peak intensity and the presence of residual silver ions mainly when diamine 38% was applied along with the SE approach.
Conclusion: Independent of the adhesive application approach, the use of diamine may be a promising alternative to increase µTBS without jeopardizing the DC of the two adhesives in carious dentinal lesions.
{"title":"Effect of Silver Diamine Fluoride on the Bonding Properties to Caries-affected Dentin.","authors":"Fabiana Suelen Figuerêdo de Siqueira, Leslee Angheloris Rivadeneira Morales, Martha Cecilia Perez Granja, Bruna de Oliveira de Melo, Valerio Monteiro-Neto, Alessandra Reis, Andres Felipe Millan Cardenas, Alessandro D Loguercio","doi":"10.3290/j.jad.a44281","DOIUrl":"https://doi.org/10.3290/j.jad.a44281","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate 1. the microtensile bond strength (µTBS) and in situ degree of conversion (DC) of adhesives applied using two bonding strategies after silver diamine fluoride (diamine) application on carious dentinal lesions, and 2. dentin etching patterns using SEM and energy dispersive x-ray spectroscopy.</p><p><strong>Materials and methods: </strong>Human molars were randomly divided into 12 experimental groups according to: 1. application of a silver diamine fluoride solution (carious dentinal lesion without silver diamine fluoride treatment [control], with 12% silver diamine fluoride [diamine 12%] or 38% silver diamine fluoride [diamine 38%]); 2. adhesives (Clearfil Universal Bond Quick [CUQ] and Scotchbond Universal [SBU]); 3. adhesive strategy (etch-and-rinse [ER] and self-etch [SE]). After restoration, the specimens were sectioned and submitted to µTBS testing. Sticks from each tooth were used for DC evaluation. To examine the changes induced by diamine before and after phosphoric acid treatment, SEM/EDX analysis was performed. Data from the µTBS and DC tests were analyzed using three-way ANOVA and Tukey's test (α = 0.05).</p><p><strong>Results: </strong>Both concentrations of diamine resulted in a statistically significantly higher mean µTBS compared to the control (p < 0.0001). Diamine 38% showed a statistically significantly higher mean µTBS for both adhesives in SE mode compared to diamine 12% (p < 0.0001). The application of diamine to carious dentinal lesions did not significantly influence the mean DC values for either adhesive (p = 0.72). SBU showed a higher mean DC compared to CUQ (p = 0.03). After diamine treatment, there was an increase in the Ca peak intensity and the presence of residual silver ions mainly when diamine 38% was applied along with the SE approach.</p><p><strong>Conclusion: </strong>Independent of the adhesive application approach, the use of diamine may be a promising alternative to increase µTBS without jeopardizing the DC of the two adhesives in carious dentinal lesions.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 2","pages":"161-172"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37862071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose: To determine the effect of Weibull analysis with censoring of cohesive failures on the evaluation of the effect of surface treatment and adhesive on the microtensile composite-composite bond strength.
Materials and methods: Surfaces of Filtek Z250 (3M Oral Care) specimens aged in distilled water for five months at 37°C were ground with SiC paper P320 or air abraded with Al2O3 and built up with the same composite using Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake) and Gluma Comfort Bond (GLU, Kulzer) adhesives. After sectioning and trimming, the specimens were stored at 37°C in distilled water for 24 h and then tested in a microtensile bond strength setup. Complete datasets of all strength data and adhesive datasets containing adhesively failed specimens were analyzed with a one-way Welch ANOVA at α = 0.05 and compared with the results of Weibull analysis applied on complete and adhesive datasets as well as complete datasets right censored for cohesive failures. Weibull shape (m) and scale (σo) parameters were estimated using the maximum likelihood method and used to calculate bond strength (σ0.10) at 10% probability of failure as a measure of system performance. The surface morphology was studied using light and scanning electron microscopy.
Results: While ANOVA indicated a significant effect of surface treatment and non-significant effect of the adhesive, the Weibull analysis results depended on bond strength characteristics and censoring. The scale parameter of the complete dataset indicating a significant effect of surface treatment for all adhesives became statistically non-significant for CSE after censoring. When this effect was evaluated by σ0.10, the non-significant effect of surface treatment for OPF and GLU became statistically significant due to censoring. The effect of the adhesive evaluated by the scale parameter was non-significant both for surfaces as well as complete and censored datasets. On the other hand, s0.10 suggested significant differences between adhesives on the ground surface for complete datasets which became statistically non-significant for the censored datasets.
Conclusion: This study indicates that the results of statistical evaluation of bond strength can be affected not only by the experimental set-up and statistical model but also the bond strength characteristics and the manner in which the strengths of cohesively failed specimens are included in calculations.
目的:利用威布尔分析对粘接失效进行修正,评价表面处理和胶粘剂对微拉伸复合材料粘接强度的影响。材料和方法:Filtek Z250 (3M Oral Care)样品在37°C蒸蒸水中陈化5个月,表面用SiC纸P320或Al2O3空气研磨,并使用Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake)和Gluma Comfort Bond (GLU, Kulzer)粘合剂建立相同的复合材料。切片、修整后,在37℃蒸馏水中保存24 h,然后在微拉伸粘结强度设置中进行测试。使用单向Welch方差分析(α = 0.05)对所有强度数据的完整数据集和包含粘合失效样品的粘合剂数据集进行分析,并与应用于完整数据集和粘合剂数据集的Weibull分析结果以及对粘合失效进行审查的完整数据集进行比较。使用最大似然法估计威布尔形状(m)和尺度(σo)参数,并用于计算10%失效概率下的粘结强度(σ0.10),作为系统性能的度量。利用光镜和扫描电镜对其表面形貌进行了研究。结果:方差分析显示表面处理的影响显著,而粘接剂的影响不显著,Weibull分析结果取决于粘合强度特征和删节。完整数据集的尺度参数表明,表面处理对所有粘合剂的显著影响,在审查后,CSE在统计上不显著。当用σ0.10评价这一效应时,表面处理对OPF和GLU的不显著影响由于剔除而变得具有统计学意义。通过尺度参数评估的粘合剂的影响对于表面以及完整和删除的数据集都是不显著的。另一方面,s0.10表明完整数据集的地面粘合剂之间存在显著差异,而对于删除数据集,这在统计上不显著。结论:黏结强度统计评价的结果不仅受试验设置和统计模型的影响,还受黏结强度特性和计算黏结破坏试件强度的方式的影响。
{"title":"The Effect of Censoring on the Statistical Evaluation of Composite-to-Composite Bond Strength.","authors":"Lukas Comba, Antonin Tichy, Pavel Bradna","doi":"10.3290/j.jad.a44283","DOIUrl":"https://doi.org/10.3290/j.jad.a44283","url":null,"abstract":"<p><strong>Purpose: </strong>To determine the effect of Weibull analysis with censoring of cohesive failures on the evaluation of the effect of surface treatment and adhesive on the microtensile composite-composite bond strength.</p><p><strong>Materials and methods: </strong>Surfaces of Filtek Z250 (3M Oral Care) specimens aged in distilled water for five months at 37°C were ground with SiC paper P320 or air abraded with Al2O3 and built up with the same composite using Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake) and Gluma Comfort Bond (GLU, Kulzer) adhesives. After sectioning and trimming, the specimens were stored at 37°C in distilled water for 24 h and then tested in a microtensile bond strength setup. Complete datasets of all strength data and adhesive datasets containing adhesively failed specimens were analyzed with a one-way Welch ANOVA at α = 0.05 and compared with the results of Weibull analysis applied on complete and adhesive datasets as well as complete datasets right censored for cohesive failures. Weibull shape (m) and scale (σo) parameters were estimated using the maximum likelihood method and used to calculate bond strength (σ0.10) at 10% probability of failure as a measure of system performance. The surface morphology was studied using light and scanning electron microscopy.</p><p><strong>Results: </strong>While ANOVA indicated a significant effect of surface treatment and non-significant effect of the adhesive, the Weibull analysis results depended on bond strength characteristics and censoring. The scale parameter of the complete dataset indicating a significant effect of surface treatment for all adhesives became statistically non-significant for CSE after censoring. When this effect was evaluated by σ0.10, the non-significant effect of surface treatment for OPF and GLU became statistically significant due to censoring. The effect of the adhesive evaluated by the scale parameter was non-significant both for surfaces as well as complete and censored datasets. On the other hand, s0.10 suggested significant differences between adhesives on the ground surface for complete datasets which became statistically non-significant for the censored datasets.</p><p><strong>Conclusion: </strong>This study indicates that the results of statistical evaluation of bond strength can be affected not only by the experimental set-up and statistical model but also the bond strength characteristics and the manner in which the strengths of cohesively failed specimens are included in calculations.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 2","pages":"183-193"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37862074","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Nicola Scotti, Riccardo Michelotto Tempesta, Damiano Pasqualini, Andrea Baldi, Edoardo Alberto Vergano, Paolo Baldissara, Mario Alovisi, Allegra Comba
Purpose: To evaluate interfacial gap and fracture resistance of endodontically treated maxillary premolars, restored with different glass-fiber reinforced materials.
Materials and methods: Eighty-four extracted intact premolars were endodontically treated and MOD cavities prepared. Specimens were divided into 7 groups (n = 12 for each) as follows: sound teeth (G1); no restoration (G2); direct composite restoration with fiber-reinforced composite (everX Posterior GC) (G3); direct composite restoration (Filtek Supreme XTE, 3M Oral Care; "FSXTE") (G4); a horizontal layer of high-viscosity flowable composite (G-ænial Flow, GC) was placed on the pulp chamber floor, 10 mm x 3 mm glass fibers (everStick NET, GC) were inserted into the cavity (G5); same procedure as in group 5 except the direct restoration was made incrementally with FSXTE (3M Oral Care) (G6); composite overlays were placed (G7). Specimens were scanned with micro-CT to evaluate 3D interfacial gaps before and after chewing simulation using Mimics software to calculate voids between restoration and tooth (dentin and enamel). These data (in mm3) were collected for statistical analysis. Thereafter, specimens were loaded to fracture using a universal testing machine. Maximum breaking loads were recorded in Newton (N). The data obtained were analyzed using two-way ANOVA and post-hoc Tukey's test (p < 0.05).
Results: ANOVA showed that horizontal glass-fiber insertions statistically significantly reduced interfacial gaps after chewing simulation. No differences in fracture resistance were found between Filtek Supreme XTE and everX Posterior; moreover, glass-fiber insertion did not significantly improve fracture resistance in either case. Composite overlays achieved significantly better fracture toughness than did direct restorations.
Conclusions: For the direct restoration of endodontically treated premolars, the insertion of glass fibers into direct composite restorations was unable to guarantee a significant increase in the fracture resistance or a significant change in the fracture pattern. However, it significantly reduced interfacial gap volume after cycling fatigue.
{"title":"3D Interfacial Gap and Fracture Resistance of Endodontically Treated Premolars Restored with Fiber-reinforced Composites.","authors":"Nicola Scotti, Riccardo Michelotto Tempesta, Damiano Pasqualini, Andrea Baldi, Edoardo Alberto Vergano, Paolo Baldissara, Mario Alovisi, Allegra Comba","doi":"10.3290/j.jad.a44286","DOIUrl":"https://doi.org/10.3290/j.jad.a44286","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate interfacial gap and fracture resistance of endodontically treated maxillary premolars, restored with different glass-fiber reinforced materials.</p><p><strong>Materials and methods: </strong>Eighty-four extracted intact premolars were endodontically treated and MOD cavities prepared. Specimens were divided into 7 groups (n = 12 for each) as follows: sound teeth (G1); no restoration (G2); direct composite restoration with fiber-reinforced composite (everX Posterior GC) (G3); direct composite restoration (Filtek Supreme XTE, 3M Oral Care; \"FSXTE\") (G4); a horizontal layer of high-viscosity flowable composite (G-ænial Flow, GC) was placed on the pulp chamber floor, 10 mm x 3 mm glass fibers (everStick NET, GC) were inserted into the cavity (G5); same procedure as in group 5 except the direct restoration was made incrementally with FSXTE (3M Oral Care) (G6); composite overlays were placed (G7). Specimens were scanned with micro-CT to evaluate 3D interfacial gaps before and after chewing simulation using Mimics software to calculate voids between restoration and tooth (dentin and enamel). These data (in mm3) were collected for statistical analysis. Thereafter, specimens were loaded to fracture using a universal testing machine. Maximum breaking loads were recorded in Newton (N). The data obtained were analyzed using two-way ANOVA and post-hoc Tukey's test (p < 0.05).</p><p><strong>Results: </strong>ANOVA showed that horizontal glass-fiber insertions statistically significantly reduced interfacial gaps after chewing simulation. No differences in fracture resistance were found between Filtek Supreme XTE and everX Posterior; moreover, glass-fiber insertion did not significantly improve fracture resistance in either case. Composite overlays achieved significantly better fracture toughness than did direct restorations.</p><p><strong>Conclusions: </strong>For the direct restoration of endodontically treated premolars, the insertion of glass fibers into direct composite restorations was unable to guarantee a significant increase in the fracture resistance or a significant change in the fracture pattern. However, it significantly reduced interfacial gap volume after cycling fatigue.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 2","pages":"215-224"},"PeriodicalIF":3.3,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3290/j.jad.a44286","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37862077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}