Novel curve fitting method based on constrained optimization for the modelling of human brain aneurysms using Mooney-Rivlin hyperelastic materials in the entire range of deformations til rupture. 基于约束优化的新型曲线拟合方法,用于使用穆尼-里夫林超弹性材料在整个变形范围内对人体脑动脉瘤进行建模,直至破裂。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Brigitta K Tóth, András Lengyel

Purpose: Brain aneurysms often prove fatal if ruptured, therefore, understanding their mechanical behaviour in the coupled system of vessels and blood flow can significantly help preventive surgical treatment. The purpose of this work was to analyse measurement data and to determine material parameters for the hyperelastic Mooney-Rivlin model for model building and numerical simulations of aneurysms.

Methods: A total of 88 human brain aneurysm specimens of 41 patients obtained from surgery were processed in this work based on the tests performed by the authors in a previous project. A novel algorithm was proposed and applied in this work to fit stress-stretch ratio curves for multiple measurement data using constrained optimization with hard conditions to comply with known mechanical behaviour.

Results: The method produced parameters of stretch ratio-stress curves for a number of groups of the specimens representing the average as well as the extreme stresses, separately for male and female subsamples. Stretch range both in compression and in tension up to rupture was covered and material stability for the entire range was also verified.

Conclusions: The fitted curves with recommended range of validity are directly applicable to numerical finite element or coupled simulations of aneurysms supporting preventive medical treatment or decision making.

目的:脑动脉瘤一旦破裂往往会致命,因此,了解其在血管和血流耦合系统中的机械行为对预防性手术治疗有很大帮助。这项工作的目的是分析测量数据,确定超弹性穆尼-里夫林模型的材料参数,用于动脉瘤模型的建立和数值模拟:方法:根据作者在之前项目中进行的测试,本研究对从手术中获得的 41 名患者的 88 个人类脑动脉瘤标本进行了处理。在这项工作中提出并应用了一种新的算法,利用约束优化技术拟合多个测量数据的应力-拉伸比曲线,并采用符合已知力学行为的苛刻条件:结果:该方法为代表平均和极端应力的多组试样生成了拉伸比-应力曲线参数,分别适用于男性和女性子样本。涵盖了压缩和拉伸直至断裂的拉伸范围,并验证了整个范围内的材料稳定性:结论:具有推荐有效范围的拟合曲线可直接用于动脉瘤的有限元数值模拟或耦合模拟,为预防性治疗或决策提供支持。
{"title":"Novel curve fitting method based on constrained optimization for the modelling of human brain aneurysms using Mooney-Rivlin hyperelastic materials in the entire range of deformations til rupture.","authors":"Brigitta K Tóth, András Lengyel","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Brain aneurysms often prove fatal if ruptured, therefore, understanding their mechanical behaviour in the coupled system of vessels and blood flow can significantly help preventive surgical treatment. The purpose of this work was to analyse measurement data and to determine material parameters for the hyperelastic Mooney-Rivlin model for model building and numerical simulations of aneurysms.</p><p><strong>Methods: </strong>A total of 88 human brain aneurysm specimens of 41 patients obtained from surgery were processed in this work based on the tests performed by the authors in a previous project. A novel algorithm was proposed and applied in this work to fit stress-stretch ratio curves for multiple measurement data using constrained optimization with hard conditions to comply with known mechanical behaviour.</p><p><strong>Results: </strong>The method produced parameters of stretch ratio-stress curves for a number of groups of the specimens representing the average as well as the extreme stresses, separately for male and female subsamples. Stretch range both in compression and in tension up to rupture was covered and material stability for the entire range was also verified.</p><p><strong>Conclusions: </strong>The fitted curves with recommended range of validity are directly applicable to numerical finite element or coupled simulations of aneurysms supporting preventive medical treatment or decision making.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 2","pages":"95-108"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139680518","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of friction and wear processes in an innovative spine stabilization system. Part 1. A study of static and kinetic friction of a metal rod-polymer cord friction joint. 创新脊柱稳定系统的摩擦和磨损过程分析。第 1 部分。金属杆-聚合物绳摩擦接头的静摩擦和动摩擦研究。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Anna Brończyk

Purpose: This analysis is the first part of research that aims to develop a model of the tribological wear of PE-UHMW cord - biometal rod combination. This type of sliding joint is applied in spine stabilization systems that enable the treatment of early-onset idiopathic scoliosis.

Methods: The friction tests included force measurements, followed by the determination of static and kinetic friction coefficients as a function of the number of the performed movement cycles, and static friction coefficient with regards to the string tension force FN in the range of 50-300 N. Additionally, the surface roughness and microscopic observations of the metal rods were made. The friction measurements were carried out at a stabilized temperature T = 38 °C in the presence of distilled water and acidic sodium lactate.

Results: The measurements confirmed the impact of both the number of completed movement cycles and the value of the force loaded on the cord on the static friction coefficient. Similar values of kinetic friction force occur for the pairs with the titanium alloys rods, as well as for the pairs with the steel and CoCr rod. The type of lubricant affected the obtained measurement results unevenly: (Ti6Al4V and Ti6Al7Nb - slight impact, steel 316L and CoCrMo - large impact). During microscopic observations, numerous wear products, were visible, including harder than the base material large conglomerates.

Conclusions: Susceptibility of polymer fibres results in its increased resistance to wear, but it can be also combined with an increase in wear of the surface of the metal rod.

目的:本分析是研究的第一部分,旨在建立聚乙烯-超高分子量帘线-生物金属杆组合的摩擦磨损模型。这种滑动接头适用于脊柱稳定系统,可用于治疗早发性特发性脊柱侧凸:摩擦测试包括力测量,然后测定静摩擦系数和动摩擦系数与运动周期数的函数关系,以及与 50-300 N 范围内的绳拉力 FN 有关的静摩擦系数。摩擦测量在蒸馏水和酸性乳酸钠存在的稳定温度 T = 38 °C 下进行:测量结果证实,完成运动循环的次数和加载在脐带上的力值对静摩擦系数都有影响。使用钛合金杆的线对以及使用钢杆和钴铬合金杆的线对的动摩擦力值相似。润滑剂类型对测量结果的影响并不均衡:(Ti6Al4V 和 Ti6Al7Nb - 影响轻微,钢 316L 和 CoCrMo - 影响较大)。在显微镜观察下,可以看到许多磨损产物,包括比基体材料更硬的大颗粒:结论:聚合物纤维的敏感性增加了其耐磨性,但同时也增加了金属棒表面的磨损。
{"title":"Analysis of friction and wear processes in an innovative spine stabilization system. Part 1. A study of static and kinetic friction of a metal rod-polymer cord friction joint.","authors":"Anna Brończyk","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>This analysis is the first part of research that aims to develop a model of the tribological wear of PE-UHMW cord - biometal rod combination. This type of sliding joint is applied in spine stabilization systems that enable the treatment of early-onset idiopathic scoliosis.</p><p><strong>Methods: </strong>The friction tests included force measurements, followed by the determination of static and kinetic friction coefficients as a function of the number of the performed movement cycles, and static friction coefficient with regards to the string tension force FN in the range of 50-300 N. Additionally, the surface roughness and microscopic observations of the metal rods were made. The friction measurements were carried out at a stabilized temperature T = 38 °C in the presence of distilled water and acidic sodium lactate.</p><p><strong>Results: </strong>The measurements confirmed the impact of both the number of completed movement cycles and the value of the force loaded on the cord on the static friction coefficient. Similar values of kinetic friction force occur for the pairs with the titanium alloys rods, as well as for the pairs with the steel and CoCr rod. The type of lubricant affected the obtained measurement results unevenly: (Ti6Al4V and Ti6Al7Nb - slight impact, steel 316L and CoCrMo - large impact). During microscopic observations, numerous wear products, were visible, including harder than the base material large conglomerates.</p><p><strong>Conclusions: </strong>Susceptibility of polymer fibres results in its increased resistance to wear, but it can be also combined with an increase in wear of the surface of the metal rod.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 1","pages":"117-130"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139680530","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of talented young male swimmers - scientific approach to the kinematic and physiological predictors of 400-m front crawl race. 对有天赋的年轻男子游泳运动员的研究--用科学方法预测 400 米前爬泳比赛的运动学和生理学因素。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Kamil Sokołowski, Marek Strzała, Magdalena Żegleń

Purpose: The purpose of this study was to assess the influence of physiological and kinematic predictors on 400-m front crawl race in young male swimmers and to consider the interrelation between them.

Methods: Nineteen male swimmers took part in this study (age: 13.5 ± 0.44 years, height: 168.6 ± 7.77 cm, body mass: 56.9 ± 10.57 kg). Measurements of physiological parameters were conducted using expired air analyzer (Start 2000 MES, Poland) during step-test in water flume. Kinematic indices were computed while analyzing video recording of 400-m front crawl race. To check for possible influence of biological age (BA) diversity in studied group, partial correlation with age control was computed.

Results: Swimming to exhaustion in water flume defined as speed at maximum oxygen uptake and anaerobic threshold ( VVO2 max and VAT) occurred to be strongly positively correlated with 400-m race speed. Speed in surface swimming zones (Vsurface) was related to ability of kinematics adjustment and significantly correlated with stroke index (SI). Vsurface at the beginning and the end of the race, i.e., at 1st, 7th and 8th lap interplayed with stroke rate (SR) measured at corresponding laps.

Conclusions: Our study showed that 400-m front crawl performance of young male swimmers is strongly dependent on swimming efficiency developed with aerobic conditioning. Significant role of proper pacing strategy was also identified, which indicates that race pace training should be implemented.

目的:本研究的目的是评估生理和运动学预测因素对年轻男子游泳运动员 400 米前爬泳比赛的影响,并考虑它们之间的相互关系:19名男性游泳运动员(年龄:13.5±0.44岁,身高:168.6±7.77厘米,体重:56.9±10.57公斤)参加了此次研究。在水槽中进行台阶测试时,使用呼出气体分析仪(Start 2000 MES,波兰)测量生理参数。在分析 400 米前爬比赛录像时计算了运动指数。为检查研究组中生物年龄(BA)多样性的可能影响,计算了与年龄对照组的部分相关性:结果:在水槽中游到筋疲力尽,即最大摄氧量和无氧阈值速度(VVO2 max 和 VAT)与 400 米比赛速度呈强烈正相关。水面游泳区的速度(Vsurface)与运动学调整能力有关,并与划水指数(SI)显著相关。比赛开始和结束时,即第 1、第 7 和第 8 圈的 Vsurface 与相应圈测得的划水速率(SR)相互影响:我们的研究表明,年轻男子游泳运动员的 400 米前爬泳成绩在很大程度上取决于通过有氧训练提高的游泳效率。正确的配速策略也起着重要作用,这表明应进行比赛配速训练。
{"title":"Study of talented young male swimmers - scientific approach to the kinematic and physiological predictors of 400-m front crawl race.","authors":"Kamil Sokołowski, Marek Strzała, Magdalena Żegleń","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to assess the influence of physiological and kinematic predictors on 400-m front crawl race in young male swimmers and to consider the interrelation between them.</p><p><strong>Methods: </strong>Nineteen male swimmers took part in this study (age: 13.5 ± 0.44 years, height: 168.6 ± 7.77 cm, body mass: 56.9 ± 10.57 kg). Measurements of physiological parameters were conducted using expired air analyzer (Start 2000 MES, Poland) during step-test in water flume. Kinematic indices were computed while analyzing video recording of 400-m front crawl race. To check for possible influence of biological age (BA) diversity in studied group, partial correlation with age control was computed.</p><p><strong>Results: </strong>Swimming to exhaustion in water flume defined as speed at maximum oxygen uptake and anaerobic threshold ( VVO2 max and VAT) occurred to be strongly positively correlated with 400-m race speed. Speed in surface swimming zones (Vsurface) was related to ability of kinematics adjustment and significantly correlated with stroke index (SI). Vsurface at the beginning and the end of the race, i.e., at 1st, 7th and 8th lap interplayed with stroke rate (SR) measured at corresponding laps.</p><p><strong>Conclusions: </strong>Our study showed that 400-m front crawl performance of young male swimmers is strongly dependent on swimming efficiency developed with aerobic conditioning. Significant role of proper pacing strategy was also identified, which indicates that race pace training should be implemented.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 1","pages":"29-38"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139680538","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Plantar pressure distribution and postural balance in beauty pageant contestants before and after wearing high-heeled shoes. 选美选手穿高跟鞋前后的足底压力分布和姿势平衡。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Jarosław Jaszczur-Nowicki, Adrianna Maja Hasiuk, Robert Podstawski, Małgorzata Potocka-Mitan, Dorota Ambroży, Jacek Perliński, Beata Ruzbarska, Joanna Magdalena Bukowska

Purpose: The aim of this study was to assess the biomechanics of the foot in beauty pageant contestants wearing shoes that increase calcaneal height. Plantar pressure distribution and postural balance were examined in women after one hour of wearing high-heeled shoes.

Methods: Foot arch measurements were conducted using EPSR1. Based on these measurements, 18 of the 19 tested women were diagnosed with significant pes cavus.

Results: The experiment revealed a significant reduction in the excessively high metatarsal arch of both feet. The mean load on the metatarsus measured at rest was 0.0% in both feet, and it increased by 0.6% in the left leg (p ≤ 0.022; Z = 2.293) and by 2.7% in the right leg (p ≤ 0.023; Z = 2.271). These results suggest that excessive stretching of the plantar fascia and impaired function of the short muscles of the foot lead to a temporary reduction in the arch of the foot. This phenomenon can be compared to stretching a bowstring and its return to the shortest length under static conditions. A statistical analysis of the results of stabilographic measurements revealed significant changes only in the left foot barycenter. An analysis of the ability to maintain postural balance revealed that the observed changes contributed to postural destabilization at p ≤ 0.011 and Z = 2.535.

Conclusions: Further research involving electromyography tests is needed to examine plantar muscle tension during isotonic contractions. The duration of the exercise-induced reduction in pes cavus should also be determined for therapeutic purposes.

目的:本研究旨在评估选美选手穿着增加小腿高度的鞋子时足部的生物力学。方法:使用 EPSR1 测量足弓:使用 EPSR1 进行足弓测量。方法:使用 EPSR1 进行足弓测量,根据这些测量结果,19 名接受测试的女性中有 18 人被诊断为严重趾空洞症:实验结果表明,双脚过高的跖骨弓明显减少。双脚静止时测得的跖骨平均负荷为 0.0%,左腿增加了 0.6%(p ≤ 0.022;Z = 2.293),右腿增加了 2.7%(p ≤ 0.023;Z = 2.271)。这些结果表明,足底筋膜的过度拉伸和足部短肌功能受损会导致足弓暂时性降低。这种现象可以比作拉伸弓弦并使其在静态条件下恢复到最短长度。对稳定测量结果的统计分析显示,只有左脚的足弓中心发生了显著变化。对保持姿势平衡能力的分析表明,观察到的变化导致姿势失稳,P ≤ 0.011,Z = 2.535:需要进一步开展肌电图测试研究,以检查等张力收缩时足底肌肉的张力。为达到治疗目的,还应确定运动引起的穴位减少的持续时间。
{"title":"Plantar pressure distribution and postural balance in beauty pageant contestants before and after wearing high-heeled shoes.","authors":"Jarosław Jaszczur-Nowicki, Adrianna Maja Hasiuk, Robert Podstawski, Małgorzata Potocka-Mitan, Dorota Ambroży, Jacek Perliński, Beata Ruzbarska, Joanna Magdalena Bukowska","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to assess the biomechanics of the foot in beauty pageant contestants wearing shoes that increase calcaneal height. Plantar pressure distribution and postural balance were examined in women after one hour of wearing high-heeled shoes.</p><p><strong>Methods: </strong>Foot arch measurements were conducted using EPSR1. Based on these measurements, 18 of the 19 tested women were diagnosed with significant pes cavus.</p><p><strong>Results: </strong>The experiment revealed a significant reduction in the excessively high metatarsal arch of both feet. The mean load on the metatarsus measured at rest was 0.0% in both feet, and it increased by 0.6% in the left leg (p ≤ 0.022; Z = 2.293) and by 2.7% in the right leg (p ≤ 0.023; Z = 2.271). These results suggest that excessive stretching of the plantar fascia and impaired function of the short muscles of the foot lead to a temporary reduction in the arch of the foot. This phenomenon can be compared to stretching a bowstring and its return to the shortest length under static conditions. A statistical analysis of the results of stabilographic measurements revealed significant changes only in the left foot barycenter. An analysis of the ability to maintain postural balance revealed that the observed changes contributed to postural destabilization at p ≤ 0.011 and Z = 2.535.</p><p><strong>Conclusions: </strong>Further research involving electromyography tests is needed to examine plantar muscle tension during isotonic contractions. The duration of the exercise-induced reduction in pes cavus should also be determined for therapeutic purposes.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 3","pages":"99-105"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139680540","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds. RunScribe™ 系统确定不同速度运动时骨盆运动变量的可靠性。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Aitor Marcos-Blanco, Felipe García-Pinillos, Alejandro Molina-Molina, Diego Jaén-Carrillo, Víctor Soto-Hermoso, Santiago Ruiz-Alias

Purpose: The aim of this study was to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running.

Methods: In this study, a treadmill protocol was implemented where the participants (n = 23) completed 3 sets of 1 minute at 5, 10 and 15 km/h.

Results: All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (<0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10%, except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (>0.92).

Conclusions: Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).

目的:本研究旨在确定 RunScribe™ 系统测量步行和跑步时骨盆运动学变量的可靠性:在这项研究中,参与者(n = 23)在跑步机上以 5、10 和 15 公里/小时的速度完成了 3 组 1 分钟的测量:结果:在步行过程中记录的所有测量值的可靠性都很低,所有变量的变异系数(CV)都大于 10%,类内相关系数(ICC)为 0.92(中小值):因此,获得的数据表明,带有 3 个 IMU 的 RunScribe™ 系统无法提供运动(即行走和跑步)过程中骨盆运动学的可靠指标。
{"title":"Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds.","authors":"Aitor Marcos-Blanco, Felipe García-Pinillos, Alejandro Molina-Molina, Diego Jaén-Carrillo, Víctor Soto-Hermoso, Santiago Ruiz-Alias","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running.</p><p><strong>Methods: </strong>In this study, a treadmill protocol was implemented where the participants (n = 23) completed 3 sets of 1 minute at 5, 10 and 15 km/h.</p><p><strong>Results: </strong>All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (<0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10%, except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (>0.92).</p><p><strong>Conclusions: </strong>Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 3","pages":"83-90"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139680541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Correlation between rotational moments of the knee and other joints during gait, including the free moment of patients with a medial meniscus tear. 步态中膝关节旋转力矩与其他关节的相关性,包括内侧半月板撕裂患者的自由力矩。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Takuya Ibara, Kiyotaka Hada, Ryosuke Karashima, Mahito Kawashima, Masaya Anan

Purpose: Rotation of the knee puts stress on the medial meniscus and can be a factor in the progression of knee osteoarthritis. This study aimed to investigate the rotational moment (internal rotation and external rotation) of the knee during gait and relationship between the rotational moments of the knee and other joints, including the free moment during gait.

Methods: We included 18 patients with medial meniscus tears (MM group) and 10 asymptomatic participants in this study. We performed 3D gait analysis. The internal ankle, knee, and hip rotational moments as well as free moment were compared between the groups. Additionally, we investigated correlations between rotational moments of the knee and other joints during gait.

Results: The maximal knee external rotation moment in the MM group was smaller than that in the asymptomatic group ( p = 0.04, g = 0.76); however, there were no significant differences in the maximal internal rotation moment between the groups ( p = 0.97, g = 0.02). The internal rotation (external knee external rotation) moment positively correlated with the hip internal rotation moment ( p 〈 0.01, r = 0.69) in the MM group.

Conclusions: The internal rotation (passive knee external rotation moment) did not decrease sufficiently, and correlation was observed between moments of the knee and hip in the MM group, especially during the late stance phase of gait. Reducing these abnormal moments during gait through rehabilitation may be important in patients with medial meniscus tears to prevent rapid progression of knee osteoarthritis.

目的:膝关节的旋转对内侧半月板施加压力,可能是膝关节骨关节炎进展的一个因素。本研究旨在研究步态中膝关节的旋转力矩(内旋转和外旋转)以及步态中膝关节与其他关节的旋转力矩(包括自由力矩)的关系。方法:本研究纳入18例内侧半月板撕裂患者(MM组)和10例无症状患者。我们进行了3D步态分析。比较两组间踝关节、膝关节、髋关节内旋转力矩及自由力矩。此外,我们还研究了步态中膝关节和其他关节旋转力矩之间的相关性。结果:MM组最大膝关节外旋力矩小于无症状组(p = 0.04, g = 0.76);各组间最大内旋力矩差异无统计学意义(p = 0.97, g = 0.02)。MM组内旋(外膝关节外旋)力矩与髋关节内旋力矩呈正相关(p < 0.01, r = 0.69)。结论:MM组内旋(被动膝关节外旋力矩)没有充分降低,且膝关节和髋关节力矩之间存在相关性,尤其是在步态站立后期。通过康复来减少这些步态异常时刻对于内侧半月板撕裂患者预防膝骨关节炎的快速进展可能是重要的。
{"title":"Correlation between rotational moments of the knee and other joints during gait, including the free moment of patients with a medial meniscus tear.","authors":"Takuya Ibara,&nbsp;Kiyotaka Hada,&nbsp;Ryosuke Karashima,&nbsp;Mahito Kawashima,&nbsp;Masaya Anan","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Rotation of the knee puts stress on the medial meniscus and can be a factor in the progression of knee osteoarthritis. This study aimed to investigate the rotational moment (internal rotation and external rotation) of the knee during gait and relationship between the rotational moments of the knee and other joints, including the free moment during gait.</p><p><strong>Methods: </strong>We included 18 patients with medial meniscus tears (MM group) and 10 asymptomatic participants in this study. We performed 3D gait analysis. The internal ankle, knee, and hip rotational moments as well as free moment were compared between the groups. Additionally, we investigated correlations between rotational moments of the knee and other joints during gait.</p><p><strong>Results: </strong>The maximal knee external rotation moment in the MM group was smaller than that in the asymptomatic group ( p = 0.04, g = 0.76); however, there were no significant differences in the maximal internal rotation moment between the groups ( p = 0.97, g = 0.02). The internal rotation (external knee external rotation) moment positively correlated with the hip internal rotation moment ( p 〈 0.01, r = 0.69) in the MM group.</p><p><strong>Conclusions: </strong>The internal rotation (passive knee external rotation moment) did not decrease sufficiently, and correlation was observed between moments of the knee and hip in the MM group, especially during the late stance phase of gait. Reducing these abnormal moments during gait through rehabilitation may be important in patients with medial meniscus tears to prevent rapid progression of knee osteoarthritis.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 4","pages":"119-126"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9727189","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cognitive functional therapy as a complementary treatment for posture and disability of chronic neck pain: secondary analysis of a randomized controlled trial. 认知功能疗法作为慢性颈部疼痛姿势和残疾的补充治疗:一项随机对照试验的二次分析。
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01
Norollah Javdaneh, Arash Shams, Sadredin Shojaedin, Łukasz Rydzik, Tadeusz Ambroży, Wiesław Chwała

Purpose: The aim of this study was to compare the effects of scapular stabilization exercise with and without cognitive functional therapy (CFT) on disability and scapular kinematics in people suffering from chronic neck pain.

Methods: A total of 72 patients with chronic non-specific neck pain were randomized into scapular stabilization exercise alone, n = 24, combined (scapular stabilization exercise + CFT), n = 24, and a control group, n = 24. Scapular kinematic and disability were measured at baseline and after the intervention.

Results: Statistically significant differences in neck pain and disability scale (NPAD) were found when the multimodal physiotherapy group including a cognitive functional approach was compared with stabilization exercises group at 6 weeks (effect size (95%CI) = -1.63 (-2.55, -.71); P = 0.019)). Regarding the neck disability index (NDI), a significant between-group difference was observed at six-week (effect size (95%CI) = -2.69 (-3.80, -1.58); P = 0.007), with the superiority of effect in multimodal physiotherapy group. A significant between-group difference was observed in the scapular upward rotation and scapular osterior tilt at 30°, 60°, 90° and 120° of shoulder adduction.

Conclusions: A group-based multimodal rehabilitation program including scapular stabilization exercise plus cognitive functional therapy was superior to group-based stabilization exercises alone for decreasing disability and, improving scapular kinematic in patients with chronic neck pain.

目的:本研究的目的是比较肩胛骨稳定运动加认知功能治疗(CFT)和不加认知功能治疗对慢性颈部疼痛患者的残疾和肩胛骨运动学的影响。方法:将72例慢性非特异性颈部疼痛患者随机分为单纯肩胛骨稳定运动组(n = 24)、联合(肩胛骨稳定运动+ CFT)组(n = 24)和对照组(n = 24)。在基线和干预后测量肩胛骨运动学和残疾。结果:6周时,包括认知功能方法的多模式物理治疗组与稳定运动组在颈部疼痛和残疾量表(NPAD)上的差异有统计学意义(95%CI) = -1.63 (-2.55, - 0.71);P = 0.019))。关于颈部残疾指数(NDI),在6周时观察到组间显著差异(95%CI) = -2.69 (-3.80, -1.58);P = 0.007),多模式物理治疗组疗效更优。在肩胛骨内收30°、60°、90°和120°时,肩胛骨向上旋转和肩胛骨向后倾斜组间差异显著。结论:以群体为基础的多模式康复方案,包括肩胛骨稳定运动加认知功能治疗,在减少慢性颈痛患者的残疾和改善肩胛骨运动方面优于单独的群体稳定运动。
{"title":"Cognitive functional therapy as a complementary treatment for posture and disability of chronic neck pain: secondary analysis of a randomized controlled trial.","authors":"Norollah Javdaneh,&nbsp;Arash Shams,&nbsp;Sadredin Shojaedin,&nbsp;Łukasz Rydzik,&nbsp;Tadeusz Ambroży,&nbsp;Wiesław Chwała","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to compare the effects of scapular stabilization exercise with and without cognitive functional therapy (CFT) on disability and scapular kinematics in people suffering from chronic neck pain.</p><p><strong>Methods: </strong>A total of 72 patients with chronic non-specific neck pain were randomized into scapular stabilization exercise alone, n = 24, combined (scapular stabilization exercise + CFT), n = 24, and a control group, n = 24. Scapular kinematic and disability were measured at baseline and after the intervention.</p><p><strong>Results: </strong>Statistically significant differences in neck pain and disability scale (NPAD) were found when the multimodal physiotherapy group including a cognitive functional approach was compared with stabilization exercises group at 6 weeks (effect size (95%CI) = -1.63 (-2.55, -.71); P = 0.019)). Regarding the neck disability index (NDI), a significant between-group difference was observed at six-week (effect size (95%CI) = -2.69 (-3.80, -1.58); P = 0.007), with the superiority of effect in multimodal physiotherapy group. A significant between-group difference was observed in the scapular upward rotation and scapular osterior tilt at 30°, 60°, 90° and 120° of shoulder adduction.</p><p><strong>Conclusions: </strong>A group-based multimodal rehabilitation program including scapular stabilization exercise plus cognitive functional therapy was superior to group-based stabilization exercises alone for decreasing disability and, improving scapular kinematic in patients with chronic neck pain.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"24 4","pages":"75-83"},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9673583","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A kinematic analysis of the basketball shot performance: impact of distance variation to the basket 篮球投篮动作的运动学分析:距离变化对篮筐的影响
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01 DOI: 10.37190/abb-01995-2021-06
Cíntia França, Élvio Rúbio Gouveia, M. Coelho-e-Silva, B. Gomes
Purpose: The aim of the current study was to examine the variation on the kinematic parameters in the basketball shot associated with the shooting distance. Methods: Twenty-seven female adolescent basketball players aged 12.1 ± 0.9 years completed 10 BS trials from a frontal position of 4.75 m and 5.75 m from the basket. Nine anatomical markers were placed on the participants’ dominant side to assess the kinematic variables. The following variables were analyzed: angle, velocity, and height at ball release; centre of mass horizontal displacement and maximum height attained; maximum hip height and hip height at release; shoulder, elbow, and knee angular position and velocity at ball release; deepest knee flexion during the preparatory phase; the peak of the angular velocity of the shoulder, elbow, and knee joints. Results: At release, the angle decreased while velocity increased significantly at 5.75 m. During the release, greater shoulder flexion and increased joint (shoulder and knee) angular velocity were observed. The deepest knee flexion and the centre of mass horizontal displacement were accentuated at 5.75 m. The ball release occurred before the peak of the jump phase. Conclusions: To compensate for the long ball trajectory to the basket, participants perform a set of adjustments in the body segmental organization to increase the ball velocity at release. The coaches’ feedback should focus on the shooting arm’s positioning and in the jump phase (to jump as close to vertical as possible). Also, a consistent shooting technique should be acquired close to the basket before expanding the shooting range.
目的:本研究的目的是研究与投篮距离相关的篮球投篮运动参数的变化。方法:27名年龄12.1±0.9岁的女青少年篮球运动员分别在距篮筐4.75 m和5.75 m的正面位置完成10项BS试验。9个解剖标记放置在参与者的优势侧,以评估运动学变量。分析了以下变量:角度、速度和球释放时的高度;质量中心水平位移和达到的最大高度;最大髋部高度和髋部高度;肩膀、肘部和膝盖在球释放时的角度位置和速度;准备阶段最深的膝关节屈曲;肩、肘和膝关节角速度的峰值。结果:在5.75 m处,释放时角度减小,速度明显增加。在释放过程中,观察到更大的肩部屈曲和关节(肩关节和膝关节)角速度增加。最深的膝关节屈曲和重心水平位移在5.75 m处加重。球的释放发生在跳跃阶段的高峰之前。结论:为了弥补球到篮筐的长轨迹,参与者在身体节段组织中进行了一系列调整,以增加球在释放时的速度。教练的反馈应该集中在投篮臂的位置和起跳阶段(跳得尽可能接近垂直)。此外,在扩大投篮范围之前,应该在篮筐附近获得一致的投篮技术。
{"title":"A kinematic analysis of the basketball shot performance: impact of distance variation to the basket","authors":"Cíntia França, Élvio Rúbio Gouveia, M. Coelho-e-Silva, B. Gomes","doi":"10.37190/abb-01995-2021-06","DOIUrl":"https://doi.org/10.37190/abb-01995-2021-06","url":null,"abstract":"Purpose: The aim of the current study was to examine the variation on the kinematic parameters in the basketball shot associated with the shooting distance. Methods: Twenty-seven female adolescent basketball players aged 12.1 ± 0.9 years completed 10 BS trials from a frontal position of 4.75 m and 5.75 m from the basket. Nine anatomical markers were placed on the participants’ dominant side to assess the kinematic variables. The following variables were analyzed: angle, velocity, and height at ball release; centre of mass horizontal displacement and maximum height attained; maximum hip height and hip height at release; shoulder, elbow, and knee angular position and velocity at ball release; deepest knee flexion during the preparatory phase; the peak of the angular velocity of the shoulder, elbow, and knee joints. Results: At release, the angle decreased while velocity increased significantly at 5.75 m. During the release, greater shoulder flexion and increased joint (shoulder and knee) angular velocity were observed. The deepest knee flexion and the centre of mass horizontal displacement were accentuated at 5.75 m. The ball release occurred before the peak of the jump phase. Conclusions: To compensate for the long ball trajectory to the basket, participants perform a set of adjustments in the body segmental organization to increase the ball velocity at release. The coaches’ feedback should focus on the shooting arm’s positioning and in the jump phase (to jump as close to vertical as possible). Also, a consistent shooting technique should be acquired close to the basket before expanding the shooting range.","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"1 1","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"69999457","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of friction and wear processes in an innovative spine stabilization system. Part 1. A study of static and kinetic friction of a metal rod-polymer cord friction joint 一种新型脊柱稳定系统的摩擦和磨损过程分析。第1部分。金属杆-聚合物绳摩擦接头静摩擦与动摩擦的研究
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01 DOI: 10.37190/abb-01962-2021-03
A. Brończyk
Purpose: This analysis is the first part of research that aims to develop a model of the tribological wear of PE-UHMW cord – biometal rod combination. This type of sliding joint is applied in spine stabilization systems that enable the treatment of early-onset idiopathic scoliosis. Methods: The friction tests included force measurements, followed by the determination of static and kinetic friction coefficients as a function of the number of the performed movement cycles, and static friction coefficient with regards to the string tension force FN in the range of 50–300 N. Additionally, the surface roughness and microscopic observations of the metal rods were made. The friction measurements were carried out at a stabilized temperature T = 38 °C in the presence of distilled water and acidic sodium lactate. Results: The measurements confirmed the impact of both the number of completed movement cycles and the value of the force loaded on the cord on the static friction coefficient. Similar values of kinetic friction force occur for the pairs with the titanium alloys rods, as well as for the pairs with the steel and CoCr rod. The type of lubricant affected the obtained measurement results unevenly: (Ti6Al4V and Ti6Al7Nb – slight impact, steel 316L and CoCrMo – large impact). During microscopic observations, numerous wear products, were visible, including harder than the base material large conglomerates. Conclusions: Susceptibility of polymer fibres results in its increased resistance to wear, but it can be also combined with an increase in wear of the surface of the metal rod.
目的:本研究是建立PE-UHMW脐带-生物金属棒组合摩擦学磨损模型的第一部分。这种类型的滑动关节应用于脊柱稳定系统,使治疗早发特发性脊柱侧凸成为可能。方法:摩擦试验包括力测量,静摩擦系数和动摩擦系数随运动次数的变化,静摩擦系数随弦张力FN在50-300 n范围内的变化,并对金属棒的表面粗糙度和微观形貌进行观察。摩擦测量是在稳定温度T = 38℃下,在蒸馏水和酸性乳酸钠存在下进行的。结果:测量结果证实了完成运动周期的次数和加载在绳上的力的值对静摩擦系数的影响。与钛合金棒、钢和CoCr棒的摩擦副的动摩擦力值相似。润滑油类型对测量结果的影响不均匀:(Ti6Al4V和Ti6Al7Nb -轻微冲击,316L钢和CoCrMo -大冲击)。在显微观察中,可以看到许多磨损产物,包括比基材更硬的大型砾岩。结论:聚合物纤维的敏感性导致其耐磨性增加,但也可能与金属棒表面磨损增加相结合。
{"title":"Analysis of friction and wear processes in an innovative spine stabilization system. Part 1. A study of static and kinetic friction of a metal rod-polymer cord friction joint","authors":"A. Brończyk","doi":"10.37190/abb-01962-2021-03","DOIUrl":"https://doi.org/10.37190/abb-01962-2021-03","url":null,"abstract":"Purpose: This analysis is the first part of research that aims to develop a model of the tribological wear of PE-UHMW cord – biometal rod combination. This type of sliding joint is applied in spine stabilization systems that enable the treatment of early-onset idiopathic scoliosis. Methods: The friction tests included force measurements, followed by the determination of static and kinetic friction coefficients as a function of the number of the performed movement cycles, and static friction coefficient with regards to the string tension force FN in the range of 50–300 N. Additionally, the surface roughness and microscopic observations of the metal rods were made. The friction measurements were carried out at a stabilized temperature T = 38 °C in the presence of distilled water and acidic sodium lactate. Results: The measurements confirmed the impact of both the number of completed movement cycles and the value of the force loaded on the cord on the static friction coefficient. Similar values of kinetic friction force occur for the pairs with the titanium alloys rods, as well as for the pairs with the steel and CoCr rod. The type of lubricant affected the obtained measurement results unevenly: (Ti6Al4V and Ti6Al7Nb – slight impact, steel 316L and CoCrMo – large impact). During microscopic observations, numerous wear products, were visible, including harder than the base material large conglomerates. Conclusions: Susceptibility of polymer fibres results in its increased resistance to wear, but it can be also combined with an increase in wear of the surface of the metal rod.","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"1 1","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"69999540","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of friction and wear processes in an innovative spine stabilization system. Part 2. A study and model of the wear of a metal rod-polymer cord friction joint 一种新型脊柱稳定系统的摩擦和磨损过程分析。第2部分。金属杆-聚合物绳摩擦接头磨损的研究与模型
IF 1 4区 医学 Q4 BIOPHYSICS Pub Date : 2022-01-01 DOI: 10.37190/abb-01963-2021-04
A. Brończyk
Purpose: The purpose of this study was to model and describe the processes and phenomena occurring during the sliding interaction between biometal rods (titanium alloys Ti6Al4V and Ti6Al7Nb, austenitic steel AISI 316L, alloy CoCrMo) and PE-UHMW cords, used in spine stabilization systems to treat early-onset idiopathic scoliosis. Methods: The wear of friction joints in two lubricating solutions (acidic sodium lactate and distilled water) at stabilized temperature T = 38 C was studied. The wear of the polymeric cords was investigated through analyses of the chemical composition of the surface of the cords and microscopic examinations of the changes occurring on this surface. In addition, microscopic examinations and EDS analyses of the wear products filtered out from the lubricating medium were carried out. Results: Metallic particles were found to be present in both lubricating solutions at each stage of the friction process. The largest amount of metallic particles was recorded after 5000 motion cycles. Conclusions: The presence of metallic wear products is an evidence of the wear of the harder metal rod due to its friction against the PE-UHMW cord. This means that the use of guided-growth implants poses a risk of inflammations in the peri-implant tissues.
目的:本研究的目的是模拟和描述生物金属棒(钛合金Ti6Al4V和Ti6Al7Nb,奥氏体钢AISI 316L,合金CoCrMo)和PE-UHMW索之间滑动相互作用的过程和现象,用于脊柱稳定系统治疗早发性特发性脊柱侧凸。方法:研究两种润滑液(酸性乳酸钠和蒸馏水)在稳定温度T = 38℃下摩擦接头的磨损。通过对钢丝表面化学成分的分析和对钢丝表面变化的显微检查,研究了钢丝的磨损情况。此外,对从润滑介质中过滤出来的磨损产物进行了显微检查和能谱分析。结果:在摩擦过程的每个阶段,金属颗粒都存在于两种润滑溶液中。在5000次运动循环后,记录到的金属颗粒数量最多。结论:金属磨损产品的存在是硬金属棒磨损的证据,因为它与PE-UHMW线的摩擦。这意味着使用引导生长的植入物会造成植入物周围组织炎症的风险。
{"title":"Analysis of friction and wear processes in an innovative spine stabilization system. Part 2. A study and model of the wear of a metal rod-polymer cord friction joint","authors":"A. Brończyk","doi":"10.37190/abb-01963-2021-04","DOIUrl":"https://doi.org/10.37190/abb-01963-2021-04","url":null,"abstract":"Purpose: The purpose of this study was to model and describe the processes and phenomena occurring during the sliding interaction between biometal rods (titanium alloys Ti6Al4V and Ti6Al7Nb, austenitic steel AISI 316L, alloy CoCrMo) and PE-UHMW cords, used in spine stabilization systems to treat early-onset idiopathic scoliosis. Methods: The wear of friction joints in two lubricating solutions (acidic sodium lactate and distilled water) at stabilized temperature T = 38 C was studied. The wear of the polymeric cords was investigated through analyses of the chemical composition of the surface of the cords and microscopic examinations of the changes occurring on this surface. In addition, microscopic examinations and EDS analyses of the wear products filtered out from the lubricating medium were carried out. Results: Metallic particles were found to be present in both lubricating solutions at each stage of the friction process. The largest amount of metallic particles was recorded after 5000 motion cycles. Conclusions: The presence of metallic wear products is an evidence of the wear of the harder metal rod due to its friction against the PE-UHMW cord. This means that the use of guided-growth implants poses a risk of inflammations in the peri-implant tissues.","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":"1 1","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"69999551","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Acta of bioengineering and biomechanics
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1