首页 > 最新文献

Acta radiologica: therapy, physics, biology最新文献

英文 中文
Radiation therapy of adrenal cortical carcinoma. 肾上腺皮质癌的放射治疗。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131965
B Percarpio, A H Knowlton

The role of radiation therapy in the management of adrenal cortical carcinoma has had little documentation in the literature. Fourteen patients with this malignancy were given 18 courses of palliative, preoperative or postoperative irradiation. The clinical results are presented. Significant palliation was obtained in all patients along with occasional long term local control of unresectable lesions.

放射治疗在肾上腺皮质癌治疗中的作用在文献中很少有记载。14例恶性肿瘤患者接受了18个疗程的姑息治疗、术前或术后放疗。并给出了临床结果。所有患者均获得了显著的缓解,并偶有不可切除病变的长期局部控制。
{"title":"Radiation therapy of adrenal cortical carcinoma.","authors":"B Percarpio,&nbsp;A H Knowlton","doi":"10.3109/02841867609131965","DOIUrl":"https://doi.org/10.3109/02841867609131965","url":null,"abstract":"<p><p>The role of radiation therapy in the management of adrenal cortical carcinoma has had little documentation in the literature. Fourteen patients with this malignancy were given 18 courses of palliative, preoperative or postoperative irradiation. The clinical results are presented. Significant palliation was obtained in all patients along with occasional long term local control of unresectable lesions.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"288-92"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131965","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"11284262","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 79
Radiation therapy of nasopharyngeal carcinoma in East Africa. 东非鼻咽癌的放射治疗。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131967
L G Larsson, P Clifford, J Einhorn, B Johansson, J Onyango, T Norin, A De Schryver, R Walstam

Results of irradiation, 1 to 3 years after treatment, are presented in 64 cases of nasopharyngeal carcinoma in East Africans. Two types of anatomic point indices are presented. Both correlate well with the results. Prophylactic irradiation of the mediastinum and both axillae was not followed by any evident improvement of the results.

64例东非鼻咽癌患者在治疗后1至3年的放射治疗结果。提出了两种解剖点指数。两者都与结果密切相关。对纵隔和双腋窝进行预防性照射后,结果没有明显改善。
{"title":"Radiation therapy of nasopharyngeal carcinoma in East Africa.","authors":"L G Larsson,&nbsp;P Clifford,&nbsp;J Einhorn,&nbsp;B Johansson,&nbsp;J Onyango,&nbsp;T Norin,&nbsp;A De Schryver,&nbsp;R Walstam","doi":"10.3109/02841867609131967","DOIUrl":"https://doi.org/10.3109/02841867609131967","url":null,"abstract":"<p><p>Results of irradiation, 1 to 3 years after treatment, are presented in 64 cases of nasopharyngeal carcinoma in East Africans. Two types of anatomic point indices are presented. Both correlate well with the results. Prophylactic irradiation of the mediastinum and both axillae was not followed by any evident improvement of the results.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"305-14"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131967","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12166024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Single-dose irradiation of bone metastases. 骨转移的单剂量照射。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131971
N H Jensen, K Roesdahl
{"title":"Single-dose irradiation of bone metastases.","authors":"N H Jensen,&nbsp;K Roesdahl","doi":"10.3109/02841867609131971","DOIUrl":"https://doi.org/10.3109/02841867609131971","url":null,"abstract":"","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"337-9"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131971","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12165901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 57
Epidermoid carcinoma of the larynx. VI. Histologic grading in the clinical evaluation. 喉部表皮样癌。六、临床评价中的组织学分级。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131966
C Lund, H Sogaard, K Jorgensen, M Hjelm-Hansen

A multifactorial microscopic grading of malignancy was performed on a clinically well examined series of 129 patients with laryngeal carcinoma. The microscopic score was statistically significantly correlated to the frequency or regional lymph-node metastases and to the death rate. It afforded important supplementary information for the T-classification and for the prognosis. Microscopic grading is an essential supplement to the clinical evaluation of risk groups.

对129例临床检查良好的喉癌患者进行了多因素显微分级。显微评分与淋巴结转移频率或局部转移率及死亡率有统计学意义。为t型分型及预后提供了重要的补充资料。显微分级是对危险人群临床评价的重要补充。
{"title":"Epidermoid carcinoma of the larynx. VI. Histologic grading in the clinical evaluation.","authors":"C Lund,&nbsp;H Sogaard,&nbsp;K Jorgensen,&nbsp;M Hjelm-Hansen","doi":"10.3109/02841867609131966","DOIUrl":"https://doi.org/10.3109/02841867609131966","url":null,"abstract":"<p><p>A multifactorial microscopic grading of malignancy was performed on a clinically well examined series of 129 patients with laryngeal carcinoma. The microscopic score was statistically significantly correlated to the frequency or regional lymph-node metastases and to the death rate. It afforded important supplementary information for the T-classification and for the prognosis. Microscopic grading is an essential supplement to the clinical evaluation of risk groups.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"293-304"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131966","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12166023","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 78
Diagnostic value of gallium-67 in malignant lymphoma. 镓-67在恶性淋巴瘤中的诊断价值。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131969
H B Makoski, H J Teske, G Becker

The results of lymphangiography and other radiologic procedures are compared with those obtained by 67Ga scintigraphy in staging of 27 patients with Hodgkin's disease and 31 patients with non-Hodgkin's lymphoma. A high degree of correlation was found between lymphangiography and 67Ga scintigraphy. Exact localization, however, was only possible by lymphangiography. In some cases, the extent of disease found on scanning appeared to be smaller compared to radiography. Within the chest 67Ga scintigraphy and conventional radiography give almost similar results. Differentiation between neoplastic and inflammatory lymph node involvement is impossible.

对27例霍奇金淋巴瘤患者和31例非霍奇金淋巴瘤患者的分期进行了淋巴管造影和其他放射学检查结果与67Ga显像的比较。淋巴管造影与67Ga显像具有高度的相关性。然而,只有通过淋巴管造影才能准确定位。在某些情况下,与x线摄影相比,扫描发现的疾病范围似乎更小。胸部67Ga显像与常规x线摄影结果几乎相似。不可能区分肿瘤性和炎性淋巴结累及。
{"title":"Diagnostic value of gallium-67 in malignant lymphoma.","authors":"H B Makoski,&nbsp;H J Teske,&nbsp;G Becker","doi":"10.3109/02841867609131969","DOIUrl":"https://doi.org/10.3109/02841867609131969","url":null,"abstract":"<p><p>The results of lymphangiography and other radiologic procedures are compared with those obtained by 67Ga scintigraphy in staging of 27 patients with Hodgkin's disease and 31 patients with non-Hodgkin's lymphoma. A high degree of correlation was found between lymphangiography and 67Ga scintigraphy. Exact localization, however, was only possible by lymphangiography. In some cases, the extent of disease found on scanning appeared to be smaller compared to radiography. Within the chest 67Ga scintigraphy and conventional radiography give almost similar results. Differentiation between neoplastic and inflammatory lymph node involvement is impossible.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"321-8"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131969","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12165899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Mantle treatment. Absorbed dose measurements in patients compared with dose planning. 地幔治疗。患者吸收剂量测量与剂量计划的比较。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131972
G Svahn-Tapper

In vivo dose measurements were performed in the hypopharnyx-oesophagus for 60 adult patients receiving mantle treatment with 60Co. The measurements of absorbed dose in more than 1 600 points were analysed and compared with dose plans for the same patients. For the technique used the mean difference between in vivo measured and planned absorbed dose is within +0.4 and -1.3 per cent with a standard error of the mean of 0.4 per cent.

对60例接受60Co地幔治疗的成人患者进行了下咽-食管的体内剂量测量。对1 600多个点的吸收剂量测量结果进行了分析,并与同一患者的剂量计划进行了比较。对于所使用的技术,体内测量剂量和计划吸收剂量之间的平均差异在+ 0.4%和- 1.3%之间,平均标准误差为0.4%。
{"title":"Mantle treatment. Absorbed dose measurements in patients compared with dose planning.","authors":"G Svahn-Tapper","doi":"10.3109/02841867609131972","DOIUrl":"https://doi.org/10.3109/02841867609131972","url":null,"abstract":"<p><p>In vivo dose measurements were performed in the hypopharnyx-oesophagus for 60 adult patients receiving mantle treatment with 60Co. The measurements of absorbed dose in more than 1 600 points were analysed and compared with dose plans for the same patients. For the technique used the mean difference between in vivo measured and planned absorbed dose is within +0.4 and -1.3 per cent with a standard error of the mean of 0.4 per cent.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"340-56"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131972","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12165902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Uptake and retention of 133Ba and 140Ba-140La in mouse tissues. 小鼠组织中133Ba和140Ba-140La的摄取和保留。
Pub Date : 1976-08-01 DOI: 10.3109/02841867609131964
L Dencker, A Nilsson, C Rönnbäck, G Walinder

The distribution of barium in the mouse has been determined qualitatively by whole-body autoradiography after i.v. administration of 133BaCl2 solution. The quantitative distribution of 104Ba and 140La has been analyzed after i.p. injections of the two nuclides in equilibrium by measuring the activity in excised organs in a two-channel scintillation counter. Approximate doses to the eyes and different parts of the skeleton have been calculated.

小鼠静脉注射133BaCl2溶液后,采用全身放射自显影法定性测定钡在小鼠体内的分布。在双通道闪烁计数器上测量了104Ba和140La的活度,分析了两种核素在平衡状态下内注射后的定量分布。对眼睛和骨骼不同部位的近似剂量已经计算出来。
{"title":"Uptake and retention of 133Ba and 140Ba-140La in mouse tissues.","authors":"L Dencker,&nbsp;A Nilsson,&nbsp;C Rönnbäck,&nbsp;G Walinder","doi":"10.3109/02841867609131964","DOIUrl":"https://doi.org/10.3109/02841867609131964","url":null,"abstract":"<p><p>The distribution of barium in the mouse has been determined qualitatively by whole-body autoradiography after i.v. administration of 133BaCl2 solution. The quantitative distribution of 104Ba and 140La has been analyzed after i.p. injections of the two nuclides in equilibrium by measuring the activity in excised organs in a two-channel scintillation counter. Approximate doses to the eyes and different parts of the skeleton have been calculated.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 4","pages":"273-87"},"PeriodicalIF":0.0,"publicationDate":"1976-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131964","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12166022","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Attenuation equalizing filter in diagnostic radiography. Advantages calculated by a Monte Carlo technique. 诊断放射学中的衰减均衡滤波器。利用蒙特卡罗技术计算出的优点。
Pub Date : 1976-06-01 DOI: 10.3109/02841867609131963
L Kusoffsky, C A Carlsson, P Edholm

The value of an attenuation equalizing filter (equalizer) has been examined by calculation using a Monte Carlo technique. The contrast enhancement caused by the equalizer is the net result of three factors: (1) The first factor arises from the contrast change caused by the difference in detector characteristics at the different energies absorbed in the detector with and without equalizer. (2) The second factor is due to the contrast change caused by the different ratios of primary to total radiation reaching the detector. (3) Finally, the third factor describes how the transparency of the object is changed by the different primary filtration with equalizer. An example is given of the reduction in radiation energy absorbed by the patient and the question of how far the attenuation equalization can be driven is discussed.

利用蒙特卡罗技术计算了衰减均衡滤波器(均衡器)的值。均衡器引起的对比度增强是三个因素综合作用的结果:(1)第一个因素是由于有均衡器和没有均衡器的探测器在吸收不同能量时,探测器特性的差异引起的对比度变化。(2)第二个因素是由于到达探测器的初级辐射与总辐射的比例不同而引起的对比度变化。(3)最后,第三个因素描述了不同带均衡器的初级过滤对物体透明度的影响。给出了病人吸收的辐射能量减少的一个例子,并讨论了衰减均衡能被驱动到什么程度的问题。
{"title":"Attenuation equalizing filter in diagnostic radiography. Advantages calculated by a Monte Carlo technique.","authors":"L Kusoffsky,&nbsp;C A Carlsson,&nbsp;P Edholm","doi":"10.3109/02841867609131963","DOIUrl":"https://doi.org/10.3109/02841867609131963","url":null,"abstract":"<p><p>The value of an attenuation equalizing filter (equalizer) has been examined by calculation using a Monte Carlo technique. The contrast enhancement caused by the equalizer is the net result of three factors: (1) The first factor arises from the contrast change caused by the difference in detector characteristics at the different energies absorbed in the detector with and without equalizer. (2) The second factor is due to the contrast change caused by the different ratios of primary to total radiation reaching the detector. (3) Finally, the third factor describes how the transparency of the object is changed by the different primary filtration with equalizer. An example is given of the reduction in radiation energy absorbed by the patient and the question of how far the attenuation equalization can be driven is discussed.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 3","pages":"259-72"},"PeriodicalIF":0.0,"publicationDate":"1976-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131963","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12153205","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Absorbed dose in mammary radiography. 乳腺x线摄影中的吸收剂量。
Pub Date : 1976-06-01 DOI: 10.3109/02841867609131962
M Karlsson, K Nygren, G Wickman, G Hettinger

By exposure measurements in an alcohol-water mixture simulating breast tissue, the absorbed dose, and dose distribution in the breast at the radiation qualities commonly used in mammary radiography have been calculated. The absorbed doses for different recording media have been compared at those radiation qualities which result in similar image qualities in the different recording media.

通过在模拟乳腺组织的酒精-水混合物中进行暴露测量,计算了乳腺放射照相中常用的辐射质量下的吸收剂量和剂量在乳腺中的分布。对不同记录介质的吸收剂量进行了比较,得出在不同记录介质中产生相似图像质量的辐射质量。
{"title":"Absorbed dose in mammary radiography.","authors":"M Karlsson,&nbsp;K Nygren,&nbsp;G Wickman,&nbsp;G Hettinger","doi":"10.3109/02841867609131962","DOIUrl":"https://doi.org/10.3109/02841867609131962","url":null,"abstract":"<p><p>By exposure measurements in an alcohol-water mixture simulating breast tissue, the absorbed dose, and dose distribution in the breast at the radiation qualities commonly used in mammary radiography have been calculated. The absorbed doses for different recording media have been compared at those radiation qualities which result in similar image qualities in the different recording media.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 3","pages":"252-8"},"PeriodicalIF":0.0,"publicationDate":"1976-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131962","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12150900","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 28
Variation of the relative biologic effectiveness with tumor size using accelerated helium ions. 使用加速氦离子的相对生物学效果随肿瘤大小的变化。
Pub Date : 1976-06-01 DOI: 10.3109/02841867609131960
J Shaeffer, A M El-Mahdi, H Aceto, W C Constable

The RBE of an accelerated helium ion beam was determined on murine osteosarcomas ranging in size from single cells to visibly detectable lung colonies of approximately 1 X 10(-2) mm3. That the RBE increased as tumor size increased provides some biologic basis for the selection of advanced cases of neoplasia for clinical trials using relatively high LET radiation sources.

加速氦离子束对小鼠骨肉瘤的RBE进行了测定,其大小从单细胞到肉眼可见的约1 × 10(-2) mm3的肺菌落不等。RBE随着肿瘤大小的增加而增加,这为临床试验选择晚期肿瘤病例使用相对高LET辐射源提供了一定的生物学依据。
{"title":"Variation of the relative biologic effectiveness with tumor size using accelerated helium ions.","authors":"J Shaeffer,&nbsp;A M El-Mahdi,&nbsp;H Aceto,&nbsp;W C Constable","doi":"10.3109/02841867609131960","DOIUrl":"https://doi.org/10.3109/02841867609131960","url":null,"abstract":"<p><p>The RBE of an accelerated helium ion beam was determined on murine osteosarcomas ranging in size from single cells to visibly detectable lung colonies of approximately 1 X 10(-2) mm3. That the RBE increased as tumor size increased provides some biologic basis for the selection of advanced cases of neoplasia for clinical trials using relatively high LET radiation sources.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 3","pages":"233-40"},"PeriodicalIF":0.0,"publicationDate":"1976-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131960","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12248942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
期刊
Acta radiologica: therapy, physics, biology
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1