The use of diode thermometers for thermoelectric power measurements 二极管温度计用于热电功率测量
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/003
P. Phillips, T. Whall, E. Parker
The feasibility of using silicon diodes as the temperature sensors for thermoelectric power measurements below room temperature has been established. The advantages and disadvantages of diodes as compared to thermocouples for this purpose are discussed.
用硅二极管作为温度传感器测量室温以下热电功率的可行性已经得到证实。讨论了二极管与热电偶相比的优点和缺点。
{"title":"The use of diode thermometers for thermoelectric power measurements","authors":"P. Phillips, T. Whall, E. Parker","doi":"10.1088/0022-3735/22/12/003","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/003","url":null,"abstract":"The feasibility of using silicon diodes as the temperature sensors for thermoelectric power measurements below room temperature has been established. The advantages and disadvantages of diodes as compared to thermocouples for this purpose are discussed.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"88 1","pages":"986-988"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80572172","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A simple method for determination of the Hall constant 测定霍尔常数的一种简单方法
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/007
B. Šantić, U. Desnica, N. Radic
A simple experimental method for determination of the Hall constant based on a continuous temperature variation is proposed. Measurements made with the procedure described are proven to be fast and accurate. Its basic advantages are simplicity and the ability to measure a larger number of points in a considerably shorter time than the standard method without a significant reduction in accuracy. It is convenient in the van der Pauw configuration, particularly for samples with asymmetrically positioned contacts, and/or for materials with a low mobility of free carriers.
提出了一种基于温度连续变化的测定霍尔常数的简单实验方法。用所描述的程序进行的测量被证明是快速和准确的。它的基本优点是简单,并且能够在相当短的时间内比标准方法测量更多的点,而不会显著降低精度。它在范德保结构中很方便,特别是对于具有不对称定位触点的样品,和/或具有低迁移率的自由载流子的材料。
{"title":"A simple method for determination of the Hall constant","authors":"B. Šantić, U. Desnica, N. Radic","doi":"10.1088/0022-3735/22/12/007","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/007","url":null,"abstract":"A simple experimental method for determination of the Hall constant based on a continuous temperature variation is proposed. Measurements made with the procedure described are proven to be fast and accurate. Its basic advantages are simplicity and the ability to measure a larger number of points in a considerably shorter time than the standard method without a significant reduction in accuracy. It is convenient in the van der Pauw configuration, particularly for samples with asymmetrically positioned contacts, and/or for materials with a low mobility of free carriers.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"57 1","pages":"997-1000"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91218354","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Demagnetising factor and noise in the fluxgate ring-core sensor 磁通门环芯传感器的消磁系数和噪声
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/009
F. Primdahl, B. Hernando, O. Nielsen, J. R. Petersen
A method for measuring the demagnetisation of fluxgate sensors is introduced and used to evaluate the demagnetising factors for four ring-core sensors having 5, 10, 15 and 20 wraps of magnetic core ribbon. The demagnetising factor is proportional to the number of wraps, and the noise is also proportional to the number of wraps except for the more noisy 5-wrap core. The estimated internal core noise was 1 pT RMS taking into consideration the demagnetising factor and the relative permeability of the core material.
介绍了一种测量磁通门传感器退磁的方法,并对具有5、10、15和20层磁芯带的4种环形磁通门传感器的退磁系数进行了计算。除噪声较大的5层磁芯外,消磁系数与层数成正比,噪声也与层数成正比。考虑消磁因素和岩心材料的相对渗透率,估计岩心内部噪声为1 pT RMS。
{"title":"Demagnetising factor and noise in the fluxgate ring-core sensor","authors":"F. Primdahl, B. Hernando, O. Nielsen, J. R. Petersen","doi":"10.1088/0022-3735/22/12/009","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/009","url":null,"abstract":"A method for measuring the demagnetisation of fluxgate sensors is introduced and used to evaluate the demagnetising factors for four ring-core sensors having 5, 10, 15 and 20 wraps of magnetic core ribbon. The demagnetising factor is proportional to the number of wraps, and the noise is also proportional to the number of wraps except for the more noisy 5-wrap core. The estimated internal core noise was 1 pT RMS taking into consideration the demagnetising factor and the relative permeability of the core material.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"185 1","pages":"1004-1008"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85087165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 51
Negligible absorption, broad passband, output window for a millimetre-wave electron cyclotron maser 毫米波电子回旋脉泽的可忽略吸收,宽通带,输出窗口
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/012
S. Spark, A. Phelps
A 0.127 mm thick Mylar output window was developed for the highly tunable Strathclyde University electron cyclotron maser (ECM). This had no measurable millimetre-wave absorption in the W-band (75-110 GHz) frequency range and could withstand atmospheric pressure. Even for G-band (140-220 GHz) oscillation of the ECM the Mylar window was thin enough to avoid Fabry-Perot effects.
为高可调谐斯特拉斯克莱德大学电子回旋脉泽(ECM)研制了0.127 mm厚的聚酯薄膜输出窗口。它在w波段(75-110 GHz)频率范围内没有可测量的毫米波吸收,并且可以承受大气压。即使对于电子对抗的g波段(140-220 GHz)振荡,聚酯薄膜窗口也足够薄,可以避免法布里-佩罗效应。
{"title":"Negligible absorption, broad passband, output window for a millimetre-wave electron cyclotron maser","authors":"S. Spark, A. Phelps","doi":"10.1088/0022-3735/22/12/012","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/012","url":null,"abstract":"A 0.127 mm thick Mylar output window was developed for the highly tunable Strathclyde University electron cyclotron maser (ECM). This had no measurable millimetre-wave absorption in the W-band (75-110 GHz) frequency range and could withstand atmospheric pressure. Even for G-band (140-220 GHz) oscillation of the ECM the Mylar window was thin enough to avoid Fabry-Perot effects.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"24 1","pages":"1015-1016"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78816868","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Anomalous DLTS signals due to small fluctuations in the reverse bias voltage on a Si diode 由于硅二极管上反向偏置电压的微小波动而引起的异常DLTS信号
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/022
W. Y. Leong, D. Robbins
A high background capacitance transient signal during DLTS measurement is reported and found to be an instrumental effect due to small fluctuations in the reverse bias on the diode under test. The authors confirm its observed behaviour from a consideration of small reverse bias fluctuations on the measured diode capacitance transient. They conclude that it is not related to deep trap centres.
在DLTS测量期间,报告了一个高背景电容瞬态信号,并发现这是由于被测二极管反向偏置的小波动引起的仪器效应。作者从对测量二极管电容瞬态的小反向偏置波动的考虑中证实了其观察到的行为。他们得出结论,这与深圈闭中心无关。
{"title":"Anomalous DLTS signals due to small fluctuations in the reverse bias voltage on a Si diode","authors":"W. Y. Leong, D. Robbins","doi":"10.1088/0022-3735/22/12/022","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/022","url":null,"abstract":"A high background capacitance transient signal during DLTS measurement is reported and found to be an instrumental effect due to small fluctuations in the reverse bias on the diode under test. The authors confirm its observed behaviour from a consideration of small reverse bias fluctuations on the measured diode capacitance transient. They conclude that it is not related to deep trap centres.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"137 1","pages":"1051-1052"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79759905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Light sensitivity of silicon strain gauges 硅应变片的光灵敏度
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/014
D. A. Gorham, B. Pickthorne
The response of typical, commercial, silicon strain gauges exposed to a high intensity xenon flash source has been measured. Photovoltages are developed at the metal-semiconductor contacts and there is also a modulation of bulk conductivity. This conductivity change is of opposite sign for p-type and n-type gauges, and is due to a combination of thermal and optical effects. These results are a precautionary reminder that the magnitude of the response may be significant in some applications.
典型的,商用的,硅应变片暴露在高强度氙气闪光源的响应已经测量。在金属-半导体接触处发展光伏,也有块体电导率的调制。这种电导率变化是相反的符号为p型和n型压力表,是由于热和光学效应的组合。这些结果是一个预防性的提醒,在某些应用中,响应的大小可能是显著的。
{"title":"Light sensitivity of silicon strain gauges","authors":"D. A. Gorham, B. Pickthorne","doi":"10.1088/0022-3735/22/12/014","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/014","url":null,"abstract":"The response of typical, commercial, silicon strain gauges exposed to a high intensity xenon flash source has been measured. Photovoltages are developed at the metal-semiconductor contacts and there is also a modulation of bulk conductivity. This conductivity change is of opposite sign for p-type and n-type gauges, and is due to a combination of thermal and optical effects. These results are a precautionary reminder that the magnitude of the response may be significant in some applications.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"37 1","pages":"1023-1025"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83248950","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measurement of surface roughness by a machine vision system 用机器视觉系统测量表面粗糙度
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/001
F. Luk, V. Huynh, W. North
A new method of surface roughness measurement was developed for use in a production environment. This method employs a microcomputer-based vision system to analyse the pattern of scattered light from the surface to derive a roughness parameter. The roughness parameters were obtained for a number of tool-steel samples which were ground to different roughnesses. A correlation curve was established by plotting the roughness parameters against the corresponding average surface roughness readings obtained from a stylus instrument. Similar correlation curves were produced for different materials such as brass and copper. Surface roughness measurement was also performed for specimens immersed in oil, a condition similar to that of a production environment. Some observable trends were found. The proposed method provides a fast and accurate means for measuring surface roughness. Its repeatability and versatility compares favourably with other methods.
提出了一种用于生产环境的表面粗糙度测量新方法。该方法采用基于微机的视觉系统对表面散射光的模式进行分析,得出粗糙度参数。得到了若干刀具钢试样经不同粗糙度磨削后的粗糙度参数。通过绘制粗糙度参数与触笔仪获得的相应平均表面粗糙度读数,建立了相关曲线。对不同的材料,如黄铜和铜,得出了相似的相关曲线。在类似于生产环境的条件下,还对浸在油中的样品进行了表面粗糙度测量。发现了一些可观察到的趋势。该方法为测量表面粗糙度提供了一种快速、准确的方法。其重复性和通用性优于其他方法。
{"title":"Measurement of surface roughness by a machine vision system","authors":"F. Luk, V. Huynh, W. North","doi":"10.1088/0022-3735/22/12/001","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/001","url":null,"abstract":"A new method of surface roughness measurement was developed for use in a production environment. This method employs a microcomputer-based vision system to analyse the pattern of scattered light from the surface to derive a roughness parameter. The roughness parameters were obtained for a number of tool-steel samples which were ground to different roughnesses. A correlation curve was established by plotting the roughness parameters against the corresponding average surface roughness readings obtained from a stylus instrument. Similar correlation curves were produced for different materials such as brass and copper. Surface roughness measurement was also performed for specimens immersed in oil, a condition similar to that of a production environment. Some observable trends were found. The proposed method provides a fast and accurate means for measuring surface roughness. Its repeatability and versatility compares favourably with other methods.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"54 1","pages":"977-980"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91017869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 104
Thermal dispersion in AC calorimetry of needle-shaped specimens 针状试样交流量热法中的热分散
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/004
M. Ivanda, D. Djurek
The propagation of thermal waves in thin needle-shaped samples is described. The waves are generated by Joule power oscillation at one end of the sample. The amplitude and phase of the temperature oscillation are dependent upon thermal diffusivity. At low frequencies no phase shift appeared and only thermal conductivity was involved in the measurement. Specific heat was evaluated on the basis of thermal diffusivity and thermal conductivity.
描述了热波在细针状试样中的传播。这些波是由样品一端的焦耳功率振荡产生的。温度振荡的幅度和相位取决于热扩散系数。在低频率没有相移出现,只有热导率参与测量。比热是根据热扩散系数和导热系数来计算的。
{"title":"Thermal dispersion in AC calorimetry of needle-shaped specimens","authors":"M. Ivanda, D. Djurek","doi":"10.1088/0022-3735/22/12/004","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/004","url":null,"abstract":"The propagation of thermal waves in thin needle-shaped samples is described. The waves are generated by Joule power oscillation at one end of the sample. The amplitude and phase of the temperature oscillation are dependent upon thermal diffusivity. At low frequencies no phase shift appeared and only thermal conductivity was involved in the measurement. Specific heat was evaluated on the basis of thermal diffusivity and thermal conductivity.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"170 1","pages":"988-992"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89859881","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Nanosecond double-frame electron microscopy of fast phase transitions 快速相变的纳秒双框架电子显微镜
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/010
O. Bostanjoglo, J. Kornitzky, R. Tornow
A high-velocity technique, capable of producing for the first time multi-frame short exposure time images in the electron microscope, is introduced. It is based on an electron image detector, consisting of a successively pulsed multichannel plate, acting as a fast shutter and a high-gain image amplifier, followed by a scintillator on positive potential as image converter. A frame-shifting plate capacitor, installed above the projector lens, places the succeeding images on unexposed areas of the multichannel plate, thus avoiding the long recovery time (milliseconds) of fired areas. Exposure times of 10-50 ns and delays >or approximately=100 ns between the shots are realised. Successive stages of laser pulse-induced crystallisation and evaporation of amorphous films are visualised with this new method.
介绍了一种在电子显微镜下首次产生多帧短曝光时间图像的高速成像技术。它基于一个电子图像探测器,由一个连续脉冲多通道板作为快速快门和高增益图像放大器组成,然后是一个正电位闪烁体作为图像转换器。安装在投影仪镜头上方的移帧板电容器将后续图像放置在多通道板的未曝光区域,从而避免了发射区域的长恢复时间(毫秒)。曝光时间为10-50纳秒,拍摄之间的延迟为b>或大约=100纳秒。激光脉冲诱导非晶膜结晶和蒸发的连续阶段用这种新方法被可视化。
{"title":"Nanosecond double-frame electron microscopy of fast phase transitions","authors":"O. Bostanjoglo, J. Kornitzky, R. Tornow","doi":"10.1088/0022-3735/22/12/010","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/010","url":null,"abstract":"A high-velocity technique, capable of producing for the first time multi-frame short exposure time images in the electron microscope, is introduced. It is based on an electron image detector, consisting of a successively pulsed multichannel plate, acting as a fast shutter and a high-gain image amplifier, followed by a scintillator on positive potential as image converter. A frame-shifting plate capacitor, installed above the projector lens, places the succeeding images on unexposed areas of the multichannel plate, thus avoiding the long recovery time (milliseconds) of fired areas. Exposure times of 10-50 ns and delays >or approximately=100 ns between the shots are realised. Successive stages of laser pulse-induced crystallisation and evaporation of amorphous films are visualised with this new method.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"27 1","pages":"1008-1011"},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87470522","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
DESIGN NOTE: A wind tunnel metabolism chamber with small volume and good air flow characteristics 设计说明:风洞代谢室,体积小,气流特性好
Pub Date : 1989-12-01 DOI: 10.1088/0022-3735/22/12/021
G. S. Bakken, D. Erskine, M. Murphy
A wind tunnel metabolism chamber is described which has a low (4.2 to 1) ratio of total to working volume to facilitate respiratory gas exchange measurements on unrestrained animals. Fine mesh screens smooth air flow to obtain 2% RMS turbulence and +or-5% uniformity. Simultaneous combinations of air temperature from -10 to 50 degrees C and wind from 0 to 3.6 m s-1 can be maintained indefinitely. A window admits simulated solar radiation to the working section.
描述了一种风洞代谢室,其总容积与工作容积之比较低(4.2比1),以方便在不受约束的动物上进行呼吸气体交换测量。细网筛平滑气流,获得2%的RMS湍流和+或5%的均匀性。气温从-10到50摄氏度,风速从0到3.6米/秒,可以无限期地保持。一个窗口允许模拟太阳辐射进入工作区域。
{"title":"DESIGN NOTE: A wind tunnel metabolism chamber with small volume and good air flow characteristics","authors":"G. S. Bakken, D. Erskine, M. Murphy","doi":"10.1088/0022-3735/22/12/021","DOIUrl":"https://doi.org/10.1088/0022-3735/22/12/021","url":null,"abstract":"A wind tunnel metabolism chamber is described which has a low (4.2 to 1) ratio of total to working volume to facilitate respiratory gas exchange measurements on unrestrained animals. Fine mesh screens smooth air flow to obtain 2% RMS turbulence and +or-5% uniformity. Simultaneous combinations of air temperature from -10 to 50 degrees C and wind from 0 to 3.6 m s-1 can be maintained indefinitely. A window admits simulated solar radiation to the working section.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"45 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85683646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
期刊
Journal of Physics E: Scientific Instruments
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1