Drift in low-cost lock-in amplifiers 低成本锁相放大器的漂移
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/003
A. Edgar
The limitation on the performance of a lock-in amplifier imposed by noise and drift in the DC amplifier is discussed. Measurements on a commercial instrument show that if the time constant tau is increased whilst holding the ratio of tau to the scan time T fixed, the output noise first falls as tau -0.5, as expected for white noise, but then rises as tau 0.09. This shows that there is an optimal setting for the time constant beyond which the signal-to-noise ratio deteriorates, and suggests that the power density of the drift and noise from the DC amplifier in this instrument has an f-1.18 spectrum. The effect of both drift and noise may be reduced by signal averaging; if the number of scans n is varied while holding both the total measurement time nT and tau /T constant, the averaged RMS noise at first decreases as roughly 1/n, but not 1/n12/, before reaching a limiting value set by white noise. Replacing the first stage DC amplifier with an equivalent circuit based on a low-drift commutating auto-zero instrumentation amplifier reduces the drift and noise by up to a factor of four, and thus extends the useful range of time constants for single-scan measurements.
讨论了直流放大器中的噪声和漂移对锁相放大器性能的限制。在商用仪器上的测量表明,如果在保持tau与扫描时间T之比固定的情况下增加时间常数tau,则输出噪声首先下降为tau -0.5,正如白噪声所期望的那样,但随后上升为tau 0.09。这表明存在一个时间常数的最佳设置,超过该时间常数,信噪比就会恶化,并且表明该仪器中来自直流放大器的漂移和噪声的功率密度具有f-1.18频谱。通过信号平均可以减小漂移和噪声的影响;如果在保持总测量时间nT和tau /T不变的情况下改变扫描次数n,在达到白噪声设定的极限值之前,平均RMS噪声首先下降大约为1/n,而不是1/n12/。将第一级直流放大器替换为基于低漂移换向自动归零仪表放大器的等效电路,可将漂移和噪声降低四倍,从而扩展了单次扫描测量的有效时间常数范围。
{"title":"Drift in low-cost lock-in amplifiers","authors":"A. Edgar","doi":"10.1088/0022-3735/22/8/003","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/003","url":null,"abstract":"The limitation on the performance of a lock-in amplifier imposed by noise and drift in the DC amplifier is discussed. Measurements on a commercial instrument show that if the time constant tau is increased whilst holding the ratio of tau to the scan time T fixed, the output noise first falls as tau -0.5, as expected for white noise, but then rises as tau 0.09. This shows that there is an optimal setting for the time constant beyond which the signal-to-noise ratio deteriorates, and suggests that the power density of the drift and noise from the DC amplifier in this instrument has an f-1.18 spectrum. The effect of both drift and noise may be reduced by signal averaging; if the number of scans n is varied while holding both the total measurement time nT and tau /T constant, the averaged RMS noise at first decreases as roughly 1/n, but not 1/n12/, before reaching a limiting value set by white noise. Replacing the first stage DC amplifier with an equivalent circuit based on a low-drift commutating auto-zero instrumentation amplifier reduces the drift and noise by up to a factor of four, and thus extends the useful range of time constants for single-scan measurements.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"64 1","pages":"551-553"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84483022","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An X-array hot-wire technique for heated turbulent flows of low velocity 低速加热湍流的x -阵列热线技术
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/021
A. Abdel-Rahman, G. Hitchman, P. Slawson, A. B. Strong
A calibration and signal analysis technique has been developed for a multiple-sensor probe, comprising an X-array hot wire and a cold wire, to account for the effects of both yaw angle and temperature on the instantaneous output signals of the X-wire. The technique assumes the response equation first proposed by Collis and Williams (1959) and involves a series of velocity calibrations at different flow angles producing independent sets of the calibration coefficients which thus describe the yaw angle dependence. The complexity of the calibration is comparable to variable angle methods which use a look-up table approach, but the present technique offers complete separation of the temperature and velocity effects on the X-wire signals over a large range of temperature without requiring additional calibration. The instantaneous velocity vector is unambiguously resolved within the full 90 degrees included angle between the sensors of a standard gold-plated X-wire, and in addition, the technique identifies the occurrence of rectification errors. The signal analysis technique is verified in the calibration apparatus and has been applied successfully in an inclined heated plane jet of low mean velocity.
为了考虑偏航角和温度对x线瞬时输出信号的影响,开发了一种多传感器探针的校准和信号分析技术,该探针由x线阵列热丝和冷丝组成。该技术假设Collis和Williams(1959)首先提出的响应方程,并涉及在不同气流角下的一系列速度校准,产生独立的校准系数集,从而描述偏角依赖性。校准的复杂性与使用查找表方法的变角度方法相当,但目前的技术提供了在大温度范围内完全分离温度和速度对x线信号的影响,而无需额外校准。在标准镀金x线传感器之间的完整90度夹角内,瞬时速度矢量可以明确地分辨出来,此外,该技术还可以识别纠正错误的发生。信号分析技术在标定装置上得到了验证,并成功地应用于低平均速度的倾斜加热平面射流。
{"title":"An X-array hot-wire technique for heated turbulent flows of low velocity","authors":"A. Abdel-Rahman, G. Hitchman, P. Slawson, A. B. Strong","doi":"10.1088/0022-3735/22/8/021","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/021","url":null,"abstract":"A calibration and signal analysis technique has been developed for a multiple-sensor probe, comprising an X-array hot wire and a cold wire, to account for the effects of both yaw angle and temperature on the instantaneous output signals of the X-wire. The technique assumes the response equation first proposed by Collis and Williams (1959) and involves a series of velocity calibrations at different flow angles producing independent sets of the calibration coefficients which thus describe the yaw angle dependence. The complexity of the calibration is comparable to variable angle methods which use a look-up table approach, but the present technique offers complete separation of the temperature and velocity effects on the X-wire signals over a large range of temperature without requiring additional calibration. The instantaneous velocity vector is unambiguously resolved within the full 90 degrees included angle between the sensors of a standard gold-plated X-wire, and in addition, the technique identifies the occurrence of rectification errors. The signal analysis technique is verified in the calibration apparatus and has been applied successfully in an inclined heated plane jet of low mean velocity.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"10 1","pages":"638-644"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79523481","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
A pulse generator output stage suitable for very low-temperature heat capacity measurements 适用于极低温热容测量的脉冲发生器输出级
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/025
M. Colclough
A low-power circuit that provides a constant-voltage output pulse is described. The stability of the pulse voltage is better than 1 part in 104 and the on/off power ratio is about 1010. The duration of the pulse is controlled by an optically isolated timing signal. The circuit has been used to drive the specimen heater in heat capacity measurements at dilution refrigerator temperatures.
描述了一种提供恒压输出脉冲的低功耗电路。脉冲电压的稳定性优于1 / 104,开关功率比约为1010。脉冲的持续时间由光隔离定时信号控制。该电路已用于驱动试样加热器在稀释冰箱温度下的热容测量。
{"title":"A pulse generator output stage suitable for very low-temperature heat capacity measurements","authors":"M. Colclough","doi":"10.1088/0022-3735/22/8/025","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/025","url":null,"abstract":"A low-power circuit that provides a constant-voltage output pulse is described. The stability of the pulse voltage is better than 1 part in 104 and the on/off power ratio is about 1010. The duration of the pulse is controlled by an optically isolated timing signal. The circuit has been used to drive the specimen heater in heat capacity measurements at dilution refrigerator temperatures.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"6 1","pages":"663-663"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75800890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optoelectronic system for investigations of non-stationary arcs 用于研究非静止电弧的光电系统
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/018
J. Hlína
A simple system for the investigation of space and time changes of non-stationary arcs in the spectral range 400-1100 nm is described. The system consists of a monochromator, an array-photodetector, amplifiers, a multiplexer, a transient recorder and a computer with peripherals. The arrangement and evaluating procedure was tested on a decaying high-pressure mercury arc and during observations of a switching arc in SF6.
本文介绍了一种用于研究400 ~ 1100nm光谱范围内非平稳电弧时空变化的简单系统。该系统由单色仪、阵列光电探测器、放大器、多路复用器、瞬态记录仪和带外设的计算机组成。在高压汞弧的衰减和SF6的开关电弧观测中,对排列和评价程序进行了测试。
{"title":"Optoelectronic system for investigations of non-stationary arcs","authors":"J. Hlína","doi":"10.1088/0022-3735/22/8/018","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/018","url":null,"abstract":"A simple system for the investigation of space and time changes of non-stationary arcs in the spectral range 400-1100 nm is described. The system consists of a monochromator, an array-photodetector, amplifiers, a multiplexer, a transient recorder and a computer with peripherals. The arrangement and evaluating procedure was tested on a decaying high-pressure mercury arc and during observations of a switching arc in SF6.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"13 1","pages":"623-626"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80160271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Dual-wavelength thermal-lens spectrometry as a sensitive and selective method for trace gas analysis 双波长热透镜光谱法作为一种灵敏、选择性的痕量气体分析方法
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/010
C. Tran, M. Franko
A novel dual-wavelength thermal-lens spectrometer with pump/probe configuration that is capable of simultaneously measuring thermal-lens signals at two different wavelengths has been developed. In this instrument, the two excitation beams are derived from the same argon-ion laser operating in a multiline mode. The sample is excited by these two wavelengths alternately and the corresponding thermal-lens signals are monitored by a He-Ne probe laser. Advantages of this dual-wavelength apparatus include its inherent sensitivity and enhanced selectivity. The selectivity is improved because the ratio of the thermal-lens signals at the two different wavelengths provides fingerprints and allows identification of the sample. Therefore, it can be used not only to detect and identify trace chemical species at very low concentration but also to analyse two-component mixtures. Using this apparatus, the detection limit for NO2 using 30 mW excitation beams modulated at 4.6 Hz is estimated to be 300 PPB.
研制了一种新型的双波长热透镜光谱仪,该光谱仪具有泵浦/探针结构,能够同时测量两个不同波长的热透镜信号。在该仪器中,两个激发光束来自同一氩离子激光器在多线模式下工作。样品被这两种波长交替激发,相应的热透镜信号由氦氖探针激光器监测。这种双波长仪器的优点包括其固有的灵敏度和增强的选择性。由于两种不同波长的热透镜信号的比例提供指纹并允许对样品进行识别,因此提高了选择性。因此,它不仅可以用于检测和鉴定极低浓度的痕量化学物质,而且可以用于分析双组分混合物。使用该装置,使用以4.6 Hz调制的30 mW激发光束对NO2的检测极限估计为300 PPB。
{"title":"Dual-wavelength thermal-lens spectrometry as a sensitive and selective method for trace gas analysis","authors":"C. Tran, M. Franko","doi":"10.1088/0022-3735/22/8/010","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/010","url":null,"abstract":"A novel dual-wavelength thermal-lens spectrometer with pump/probe configuration that is capable of simultaneously measuring thermal-lens signals at two different wavelengths has been developed. In this instrument, the two excitation beams are derived from the same argon-ion laser operating in a multiline mode. The sample is excited by these two wavelengths alternately and the corresponding thermal-lens signals are monitored by a He-Ne probe laser. Advantages of this dual-wavelength apparatus include its inherent sensitivity and enhanced selectivity. The selectivity is improved because the ratio of the thermal-lens signals at the two different wavelengths provides fingerprints and allows identification of the sample. Therefore, it can be used not only to detect and identify trace chemical species at very low concentration but also to analyse two-component mixtures. Using this apparatus, the detection limit for NO2 using 30 mW excitation beams modulated at 4.6 Hz is estimated to be 300 PPB.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"11 1","pages":"586-589"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77762694","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Field emission gun for microengineering application 微工程用场致发射枪
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/014
A. Delong, V. Kolarik
An electron gun has been designed for a TFE W 100 ZrO cathode with a magnetic lens for voltages up to 15 kV. The main fields of application are assumed to be electron beam lithography, electron beam diagnosis and analysis of microstructures.
设计了一种电子枪,用于电压高达15 kV的TFE w100 ZrO阴极,带有磁透镜。电子束的主要应用领域是电子束光刻、电子束诊断和微结构分析。
{"title":"Field emission gun for microengineering application","authors":"A. Delong, V. Kolarik","doi":"10.1088/0022-3735/22/8/014","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/014","url":null,"abstract":"An electron gun has been designed for a TFE W 100 ZrO cathode with a magnetic lens for voltages up to 15 kV. The main fields of application are assumed to be electron beam lithography, electron beam diagnosis and analysis of microstructures.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"132 1","pages":"612-614"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79657273","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A cheap capacitance meter for the measurement of fast transients and suitable for deep-level transient spectroscopy 一种廉价的快速瞬变测量电容计,适用于深能级瞬变光谱
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/026
M. Slifkin, J. Ely
A cheap, simple device has been built which enables short-lived capacitance transients to be measured. The device uses phase modulation. This device is particularly suitable for deep-level transient spectroscopy (DLTS).
一种便宜、简单的装置可以测量短暂电容瞬变。该装置采用相位调制。该装置特别适用于深能级瞬态光谱(DLTS)。
{"title":"A cheap capacitance meter for the measurement of fast transients and suitable for deep-level transient spectroscopy","authors":"M. Slifkin, J. Ely","doi":"10.1088/0022-3735/22/8/026","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/026","url":null,"abstract":"A cheap, simple device has been built which enables short-lived capacitance transients to be measured. The device uses phase modulation. This device is particularly suitable for deep-level transient spectroscopy (DLTS).","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"27 1","pages":"664-666"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75736407","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
DESIGN NOTE: Mass analyser optics for wide-beam ion sources in ion implantation systems 设计说明:用于离子注入系统中宽光束离子源的质量分析仪光学器件
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/027
B. Krishnarajulu, G. Muralidhar, S. Mohan, A. Menon
Ion implantation systems, used for producing high-current ion beams, employ wide-beam ion sources which are rotated through 90 degrees . These sources need mass analyser optics which are different from the conventional design. The authors present results of calculation of the image distance as a function of entrance and exit angles of a sector magnet mass analyser having such a source. These computations have been performed for the magnetic deflection angles 45 degrees , 60 degrees and 90 degrees . The details of the computations carried out using the computer program MODBEAM, developed for this purpose, are also discussed.
用于产生大电流离子束的离子注入系统采用旋转90度的宽束离子源。这些源需要不同于传统设计的质量分析光学器件。作者给出了具有这种源的扇形磁体质量分析仪的像距作为入口和出口角函数的计算结果。分别对45度、60度和90度的磁偏转角进行了计算。本文还讨论了使用为此目的开发的计算机程序MODBEAM进行计算的细节。
{"title":"DESIGN NOTE: Mass analyser optics for wide-beam ion sources in ion implantation systems","authors":"B. Krishnarajulu, G. Muralidhar, S. Mohan, A. Menon","doi":"10.1088/0022-3735/22/8/027","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/027","url":null,"abstract":"Ion implantation systems, used for producing high-current ion beams, employ wide-beam ion sources which are rotated through 90 degrees . These sources need mass analyser optics which are different from the conventional design. The authors present results of calculation of the image distance as a function of entrance and exit angles of a sector magnet mass analyser having such a source. These computations have been performed for the magnetic deflection angles 45 degrees , 60 degrees and 90 degrees . The details of the computations carried out using the computer program MODBEAM, developed for this purpose, are also discussed.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"20 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86482268","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A dual-beam flash-photolysis fluorescence technique for use with pulsed lasers 用于脉冲激光器的双光束闪光-光解荧光技术
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/015
C. A. Hamilton, K. Mclauchlan, S. Nattrass
A novel dual-beam fluorescence measurement technique is described which involves beam splitting of an excitation pulse so as to cause fluorescence from experimental and reference samples. The emissions are combined at a single detector, but separated in time. The technique is illustrated using measurements resulting from a free radical reaction performed in the absence and presence of an applied external magnetic field.
描述了一种新的双光束荧光测量技术,该技术涉及激发脉冲的光束分裂,从而使实验样品和参考样品产生荧光。这些辐射在一个探测器上结合在一起,但在时间上是分开的。该技术是通过在外加磁场存在和不存在的情况下进行自由基反应的测量结果来说明的。
{"title":"A dual-beam flash-photolysis fluorescence technique for use with pulsed lasers","authors":"C. A. Hamilton, K. Mclauchlan, S. Nattrass","doi":"10.1088/0022-3735/22/8/015","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/015","url":null,"abstract":"A novel dual-beam fluorescence measurement technique is described which involves beam splitting of an excitation pulse so as to cause fluorescence from experimental and reference samples. The emissions are combined at a single detector, but separated in time. The technique is illustrated using measurements resulting from a free radical reaction performed in the absence and presence of an applied external magnetic field.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"1 1","pages":"615-616"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83530797","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Furnace control using non-thermal parameters (semiconductor growth) 使用非热参数(半导体生长)控制炉膛
Pub Date : 1989-08-01 DOI: 10.1088/0022-3735/22/8/016
G. R. Duffill, D. Dunstan
Conventionally, furnaces are controlled by measuring the temperature and processing the data by, for example, a three-term temperature controller. The authors report successful control of a furnace using non-thermal data taken directly from the heated object. The expansion of a sample tube, in a simulation of a horizontal Bridgmann system for growing GaAs in a quartz tube, provided the integral term of a three-term controller.
传统上,炉子是通过测量温度和处理数据来控制的,例如,一个三段式温度控制器。作者报告了使用直接从被加热物体获取的非热数据成功控制炉子。在石英管中生长砷化镓的水平Bridgmann系统的模拟中,样品管的膨胀提供了三项控制器的积分项。
{"title":"Furnace control using non-thermal parameters (semiconductor growth)","authors":"G. R. Duffill, D. Dunstan","doi":"10.1088/0022-3735/22/8/016","DOIUrl":"https://doi.org/10.1088/0022-3735/22/8/016","url":null,"abstract":"Conventionally, furnaces are controlled by measuring the temperature and processing the data by, for example, a three-term temperature controller. The authors report successful control of a furnace using non-thermal data taken directly from the heated object. The expansion of a sample tube, in a simulation of a horizontal Bridgmann system for growing GaAs in a quartz tube, provided the integral term of a three-term controller.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"10 1","pages":"617-618"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75055982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Journal of Physics E: Scientific Instruments
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1