英文 中文
CBCT image reconstruction of a moving target with an on-board imaging system for radiation therapy 基于车载放射治疗成像系统的运动目标CBCT图像重建
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829337
K. Usui, S. Kabuki, C. Kurokawa, S. Sugimoto, K. Sasai, E. Kunieda, K. Ogawa
To accomplish accurate irradiation to a target, image information about the target is very useful in radiotherapy. A kilo-voltage cone-beam computed tomography (kV-CBCT) system mounted on a linear accelerator can verify the accuracy of the set-up position and the size and location of the target on each treatment day. However, the gantry of the CBCT system is heavy and so requires a long data acquisition time. As a result, image distortion occurs in the case of a moving target. In this study, we proposed a method to reconstruct a target less affected by any motion of the target, and evaluated the proposed method with a moving phantom. In our method, CBCT images of the moving phantom were acquired, and the target position in two directions was detected with a template matching method using these projection images. And we selected data acquisition angles of the projection images in which the target was located in predefined regions in the projection images, and made a sinogram with the projection image of selected angles. A less blurred image was reconstructed with a filtered-backprojection method from the sinogram. The results of experiments showed that the blurring caused by the movement of the phantom was reduced with our proposed method.
为了实现对目标的精确照射,目标的图像信息在放射治疗中是非常有用的。安装在直线加速器上的千电压锥束计算机断层扫描(kV-CBCT)系统可以在每个治疗日验证设置位置的准确性以及目标的大小和位置。然而,CBCT系统的机架较重,数据采集时间较长。因此,在运动目标的情况下,图像会发生畸变。在本研究中,我们提出了一种重建受目标运动影响较小的目标的方法,并使用运动的幻影对该方法进行了评估。在我们的方法中,获取运动幻影的CBCT图像,并利用这些投影图像采用模板匹配方法检测两个方向上的目标位置。选择目标位于投影图像预定义区域的投影图像的数据采集角度,与所选角度的投影图像做正弦图。用滤波反投影法从正弦图中重建出模糊程度较低的图像。实验结果表明,本文提出的方法能有效地消除因幻影运动引起的模糊。
{"title":"CBCT image reconstruction of a moving target with an on-board imaging system for radiation therapy","authors":"K. Usui, S. Kabuki, C. Kurokawa, S. Sugimoto, K. Sasai, E. Kunieda, K. Ogawa","doi":"10.1109/NSSMIC.2013.6829337","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829337","url":null,"abstract":"To accomplish accurate irradiation to a target, image information about the target is very useful in radiotherapy. A kilo-voltage cone-beam computed tomography (kV-CBCT) system mounted on a linear accelerator can verify the accuracy of the set-up position and the size and location of the target on each treatment day. However, the gantry of the CBCT system is heavy and so requires a long data acquisition time. As a result, image distortion occurs in the case of a moving target. In this study, we proposed a method to reconstruct a target less affected by any motion of the target, and evaluated the proposed method with a moving phantom. In our method, CBCT images of the moving phantom were acquired, and the target position in two directions was detected with a template matching method using these projection images. And we selected data acquisition angles of the projection images in which the target was located in predefined regions in the projection images, and made a sinogram with the projection image of selected angles. A less blurred image was reconstructed with a filtered-backprojection method from the sinogram. The results of experiments showed that the blurring caused by the movement of the phantom was reduced with our proposed method.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"140 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131450410","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Leading edge of the technological developments of Planar Pixel Sensors and prospects for ATLAS HL-LHC upgrade 平面像元传感器技术发展前沿及ATLAS HL-LHC升级展望
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829542
A. Lounis
To investigate the suitability of pixel sensors using the proven planar technology for the upgraded tracker, the ATLAS Planar Pixel Sensor R&D Project was established comprising 18 institutes and more than 80 scientists. Main areas of research are the performance of planar pixel sensors at highest fluences, the exploration of possibilities for cost reduction to enable the instrumentation of large areas, the achievement of slim or active edges to provide low geometric inefficiencies without the need for shingling of modules and the investigation of the operation of highly irradiated sensors at low thresholds to increase the efficiency. Most important of the recent accomplishments obtained in research institutes members of the R&D project is given. In addition, the production of prototype sensors also for the outer layers has seen significant progress within the recent months and first characterization results will be shown. On the topic of edge efficiencies, substantial achievements have been made in view of planar active edges. We will show results from successful productions with two vendors. In addition, the status of the SCP post-processing technology will be summarized; this process could be applied to most sensors independent of their manufacturer which enables the creation of almost active edges even for originally non-slim-edge sensors.
为了研究使用成熟的平面技术的像素传感器在升级跟踪器中的适用性,ATLAS平面像素传感器研发项目由18个研究所和80多名科学家组成。主要研究领域是平面像素传感器在最高影响下的性能,探索降低成本的可能性,使仪器能够大面积使用,实现细长或活动边缘,以提供低几何效率,而不需要模块的拼接,以及研究高辐照传感器在低阈值下的操作,以提高效率。本文给出了该项目研究机构成员最近取得的最重要成果。此外,用于外层的原型传感器的生产在最近几个月内取得了重大进展,并将显示第一个表征结果。在边效率方面,针对平面活动边已经取得了相当大的成果。我们将展示两家供应商成功生产的结果。此外,对SCP后处理技术的现状进行了综述;该过程可以应用于大多数独立于制造商的传感器,即使对于最初的非细边传感器,也可以创建几乎活动的边缘。
{"title":"Leading edge of the technological developments of Planar Pixel Sensors and prospects for ATLAS HL-LHC upgrade","authors":"A. Lounis","doi":"10.1109/NSSMIC.2013.6829542","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829542","url":null,"abstract":"To investigate the suitability of pixel sensors using the proven planar technology for the upgraded tracker, the ATLAS Planar Pixel Sensor R&D Project was established comprising 18 institutes and more than 80 scientists. Main areas of research are the performance of planar pixel sensors at highest fluences, the exploration of possibilities for cost reduction to enable the instrumentation of large areas, the achievement of slim or active edges to provide low geometric inefficiencies without the need for shingling of modules and the investigation of the operation of highly irradiated sensors at low thresholds to increase the efficiency. Most important of the recent accomplishments obtained in research institutes members of the R&D project is given. In addition, the production of prototype sensors also for the outer layers has seen significant progress within the recent months and first characterization results will be shown. On the topic of edge efficiencies, substantial achievements have been made in view of planar active edges. We will show results from successful productions with two vendors. In addition, the status of the SCP post-processing technology will be summarized; this process could be applied to most sensors independent of their manufacturer which enables the creation of almost active edges even for originally non-slim-edge sensors.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131987754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
EndoTOFPET-US: Towards a multi-modal endoscope for Ultrasound and Time of Flight PET EndoTOFPET-US:用于超声和飞行时间PET的多模态内窥镜
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829146
M. Pizzichemi
The EndoTOFPET-US collaboration is developing a multi-modal imaging tool combining Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200ps FWHM and to achieve ~1mm spatial resolution for the PET head, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. The current status of the project is presented in this paper.
EndoTOFPET-US合作正在开发一种多模态成像工具,将超声和飞行时间正电子发射断层扫描结合成内窥镜成像设备。该项目的目标是获得约200ps FWHM的重合时间分辨率,PET头的空间分辨率达到~1mm,同时将所有组件集成在一个非常紧凑的适合内窥镜使用的探测器中。该扫描仪旨在用于诊断和外科肿瘤学,以及在新的生物标志物的临床测试中发挥重要作用,特别是针对前列腺癌和胰腺癌。本文介绍了该项目的现状。
{"title":"EndoTOFPET-US: Towards a multi-modal endoscope for Ultrasound and Time of Flight PET","authors":"M. Pizzichemi","doi":"10.1109/NSSMIC.2013.6829146","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829146","url":null,"abstract":"The EndoTOFPET-US collaboration is developing a multi-modal imaging tool combining Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200ps FWHM and to achieve ~1mm spatial resolution for the PET head, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. The current status of the project is presented in this paper.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"166 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132529024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of optimal CT spectrum for PET attenuation correction PET衰减校正的最佳CT谱分析
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829122
Xue Rui, Y. Long, E. Asma, A. Alessio, Paul Kinahan, B. De Man
One advantage of a combined PET/CT scanner is that a fast CT acquisition provides a high quality attenuation correction map for PET reconstruction. A diagnostic CT system typically operates in a voltage range from 80 kVp to 140 kVp. The choice of optimal spectrum depends on the specific application. In diagnostic imaging, contrast, noise and dose all play important roles. The designated CT scan for PET attenuation correction has different image quality requirements compared to diagnostic CT. For example, at 511 keV, the contrast between different materials reduces significantly and there is typically no interest in distinguishing small contrast variations. On the other hand, it is important that the error on the attenuation map is small, and especially bias in the CT attenuation correction (CTAC) map could introduce significant artifacts in PET images which may affect clinical diagnosis. We are interested in operating the CT scanner at the lowest possible dose while still providing accurate attenuation correction. However, at these very low dose levels, the effects of electronic noise can become significant. In the study presented here, we analyzed the impacts of the X-ray tube voltage, current and filtration by metal filter on the quality of the CTAC by evaluating noise variance and bias at various dose levels.
PET/CT联合扫描仪的一个优点是,快速的CT采集为PET重建提供了高质量的衰减校正图。诊断CT系统通常在80 kVp到140 kVp的电压范围内工作。最佳频谱的选择取决于具体的应用。在诊断成像中,造影剂、噪声和剂量都起着重要的作用。与诊断CT相比,用于PET衰减校正的指定CT扫描具有不同的图像质量要求。例如,在511 keV时,不同材料之间的对比度显着降低,并且通常没有兴趣区分小的对比度变化。另一方面,重要的是衰减图上的误差要小,特别是CT衰减校正(CTAC)图中的偏差可能会在PET图像中引入明显的伪影,从而影响临床诊断。我们感兴趣的是在尽可能低的剂量下操作CT扫描仪,同时仍然提供准确的衰减校正。然而,在这些非常低的剂量水平下,电子噪声的影响可能变得显著。在本研究中,我们通过评估不同剂量水平下的噪声方差和偏置,分析了x射线管电压、电流和金属滤波器滤波对CTAC质量的影响。
{"title":"Analysis of optimal CT spectrum for PET attenuation correction","authors":"Xue Rui, Y. Long, E. Asma, A. Alessio, Paul Kinahan, B. De Man","doi":"10.1109/NSSMIC.2013.6829122","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829122","url":null,"abstract":"One advantage of a combined PET/CT scanner is that a fast CT acquisition provides a high quality attenuation correction map for PET reconstruction. A diagnostic CT system typically operates in a voltage range from 80 kVp to 140 kVp. The choice of optimal spectrum depends on the specific application. In diagnostic imaging, contrast, noise and dose all play important roles. The designated CT scan for PET attenuation correction has different image quality requirements compared to diagnostic CT. For example, at 511 keV, the contrast between different materials reduces significantly and there is typically no interest in distinguishing small contrast variations. On the other hand, it is important that the error on the attenuation map is small, and especially bias in the CT attenuation correction (CTAC) map could introduce significant artifacts in PET images which may affect clinical diagnosis. We are interested in operating the CT scanner at the lowest possible dose while still providing accurate attenuation correction. However, at these very low dose levels, the effects of electronic noise can become significant. In the study presented here, we analyzed the impacts of the X-ray tube voltage, current and filtration by metal filter on the quality of the CTAC by evaluating noise variance and bias at various dose levels.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130453698","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Ultra light drift chambers for precision physics 用于精密物理的超轻漂移室
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829601
M. Cascella, F. Grancagnolo, A. L’Erario, A. Miccoli, S. Rella, M. Spedicato, G. Tassielli
We present a novel low mass drift chamber concept, developed in order to fulfill the requirements imposed by the search for extremely rare processes, which require high resolutions (order of 50-200 keV/c) for particle momenta in a range (50-300 MeV/c) totally dominated by the multiple scattering contribution. The innovative concept in the chamber design is the separation of the gas containment and the mechanical support structure. We describe a geometry optimization procedure and a new semi-automatic wiring strategy with a feed-through-less wire anchoring system.
我们提出了一种新颖的低质量漂移室概念,旨在满足寻找极其罕见过程所施加的要求,这些过程需要高分辨率(50-200 keV/c)的粒子动量范围(50-300 MeV/c)完全由多重散射贡献主导。腔室设计的创新理念是气体容器和机械支撑结构的分离。我们描述了一种几何优化程序和一种新的半自动布线策略,该策略具有无馈通导线锚定系统。
{"title":"Ultra light drift chambers for precision physics","authors":"M. Cascella, F. Grancagnolo, A. L’Erario, A. Miccoli, S. Rella, M. Spedicato, G. Tassielli","doi":"10.1109/NSSMIC.2013.6829601","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829601","url":null,"abstract":"We present a novel low mass drift chamber concept, developed in order to fulfill the requirements imposed by the search for extremely rare processes, which require high resolutions (order of 50-200 keV/c) for particle momenta in a range (50-300 MeV/c) totally dominated by the multiple scattering contribution. The innovative concept in the chamber design is the separation of the gas containment and the mechanical support structure. We describe a geometry optimization procedure and a new semi-automatic wiring strategy with a feed-through-less wire anchoring system.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134074002","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Silicon planar structures as detectors for microbeam radiation therapy 硅平面结构作为微束放射治疗的探测器
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829792
I. Anokhin, M. Lerch, M. Petasecca, O. Zinets, A. Rosenfeld
Calculations of responses for experimentally studied silicon planar structures (epitaxial single-strip silicon diodes) have been carried out for various profiles of microbeams. The spatial distribution of responses on the microbeam radiation therapy (MRT) beams has been calculated taken into account both electrical field distribution inside of the detector and recombination in the diffusion region. Contributions to the responses from the space charge region (SCR) and the diffusion region are compared. It has been shown that the spatial resolution and the detector efficiency in edge on mode of the detector relative to X-ray microbeam can be higher than for the face on irradiation geometry. The response functions of diodes under MRT irradiation for a simple physical model have been obtained analytically. That allows calculating responses using the convolution procedure for different beam profiles.
对实验研究的硅平面结构(外延单条硅二极管)的各种微光束的响应进行了计算。考虑检测器内部电场分布和扩散区的复合,计算了微束放射治疗(MRT)光束响应的空间分布。比较了空间电荷区(SCR)和扩散区对响应的贡献。研究结果表明,相对于x射线微光束,探测器在边缘模式下的空间分辨率和探测效率可以高于在面照射几何上的空间分辨率和探测效率。得到了简单物理模型下二极管在MRT照射下的响应函数。这允许使用卷积程序计算不同光束剖面的响应。
{"title":"Silicon planar structures as detectors for microbeam radiation therapy","authors":"I. Anokhin, M. Lerch, M. Petasecca, O. Zinets, A. Rosenfeld","doi":"10.1109/NSSMIC.2013.6829792","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829792","url":null,"abstract":"Calculations of responses for experimentally studied silicon planar structures (epitaxial single-strip silicon diodes) have been carried out for various profiles of microbeams. The spatial distribution of responses on the microbeam radiation therapy (MRT) beams has been calculated taken into account both electrical field distribution inside of the detector and recombination in the diffusion region. Contributions to the responses from the space charge region (SCR) and the diffusion region are compared. It has been shown that the spatial resolution and the detector efficiency in edge on mode of the detector relative to X-ray microbeam can be higher than for the face on irradiation geometry. The response functions of diodes under MRT irradiation for a simple physical model have been obtained analytically. That allows calculating responses using the convolution procedure for different beam profiles.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"152 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133976670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
FlexToT - Current mode ASIC for readout of common cathode SiPM arrays 用于普通阴极SiPM阵列读出的电流模式ASIC
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829761
A. Comerma, D. Gascón, L. Freixas, L. Garrido, R. Graciani, J. Marı́n, G. Martinez, J. Pérez, P. Rato Mendes, J. Castilla, J. Cela, José María Fernéndez-Varea, I. Sarasola
A front end application specific integrated circuit (ASIC) for the readout of common cathode Silicon Photo-Multipliers arrays is presented with the following features: wide dynamic range, high speed, multi channel, low input impedance current amplifier, low power (≈10mW per channel), common cathode connection, directly coupled input with common mode voltage control and separated timing and charge signal output.A 16 channel prototype with 16 independent outputs for energy and pile-up detection and a single fast timing output is described. The low jitter current mode processing together with a configurable differential current mode logic (CML) output provides a timing signal suitable for Time of Flight (TOF) applications, such as TOF-PET (Positron Emission Tomography). Each channel delivers a digital output of a Time Over Threshold (TOT) type with a pulse width proportional to peak current (charge) input. The current mode input stage features a novel double feedback; a low speed feedback loop keeps input node voltage constant while a higher speed feedback loop keeps input impedance low. Dedicated circuitry allows SiPM high over-voltage operation, thus maximizing Photon Detection Efficiency (PDE) and timing resolution. Design was submitted in June 2012 in Austria Microsystems (AMS) 0.35 μm HBT BiCMOS technology and is under test.
提出了一种用于共阴极硅光倍增器阵列读出的前端专用集成电路(ASIC),该电路具有宽动态范围、高速、多通道、低输入阻抗电流放大器、低功率(每通道≈10mW)、共阴极连接、直接耦合输入、共模电压控制、定时和电荷信号分离输出等特点。描述了一个16通道原型,具有16个独立的能量和堆积检测输出和一个快速定时输出。低抖动电流模式处理与可配置的差分电流模式逻辑(CML)输出一起提供适合于飞行时间(TOF)应用的定时信号,例如TOF- pet(正电子发射断层扫描)。每个通道提供一个时间超过阈值(TOT)类型的数字输出,脉冲宽度与峰值电流(电荷)输入成比例。电流模式输入级具有新颖的双反馈;低速反馈回路保持输入节点电压恒定,高速反馈回路保持输入阻抗低。专用电路允许SiPM高过电压操作,从而最大限度地提高光子探测效率(PDE)和时间分辨率。设计于2012年6月在奥地利微系统公司(AMS)提交了0.35 μm HBT BiCMOS技术,目前正在测试中。
{"title":"FlexToT - Current mode ASIC for readout of common cathode SiPM arrays","authors":"A. Comerma, D. Gascón, L. Freixas, L. Garrido, R. Graciani, J. Marı́n, G. Martinez, J. Pérez, P. Rato Mendes, J. Castilla, J. Cela, José María Fernéndez-Varea, I. Sarasola","doi":"10.1109/NSSMIC.2013.6829761","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829761","url":null,"abstract":"A front end application specific integrated circuit (ASIC) for the readout of common cathode Silicon Photo-Multipliers arrays is presented with the following features: wide dynamic range, high speed, multi channel, low input impedance current amplifier, low power (≈10mW per channel), common cathode connection, directly coupled input with common mode voltage control and separated timing and charge signal output.A 16 channel prototype with 16 independent outputs for energy and pile-up detection and a single fast timing output is described. The low jitter current mode processing together with a configurable differential current mode logic (CML) output provides a timing signal suitable for Time of Flight (TOF) applications, such as TOF-PET (Positron Emission Tomography). Each channel delivers a digital output of a Time Over Threshold (TOT) type with a pulse width proportional to peak current (charge) input. The current mode input stage features a novel double feedback; a low speed feedback loop keeps input node voltage constant while a higher speed feedback loop keeps input impedance low. Dedicated circuitry allows SiPM high over-voltage operation, thus maximizing Photon Detection Efficiency (PDE) and timing resolution. Design was submitted in June 2012 in Austria Microsystems (AMS) 0.35 μm HBT BiCMOS technology and is under test.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127618388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 25
Scintillation properties of ceramic Ce-doped Gd3(Ga,Al)5O12 ce掺杂Gd3(Ga,Al)5O12陶瓷的闪烁特性
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829666
T. Yanagida, Y. Fujimoto, H. Yagi, T. Yanagitani
Ceramic Ce 0.1% doped Gd3(Ga,Al)5O12 scintillator fabricated by Konoshima Chemical was evaluated. In X-ray induced radioluminescence, intense emission peak appeared around 530 nm. When 137Cs 662 keV γ-ray was irradiated, scintillation light yield turned out to be 70000 ph/MeV by using Si-APD. Scintillation decay timewas a typical value of Ce-doped garnet materials, ~ 100 ns.
对河岛化学制备的陶瓷Ce 0.1%掺杂Gd3(Ga,Al)5O12闪烁体进行了评价。在x射线诱导辐射发光中,在530 nm左右出现了强烈的发射峰。当137Cs 662 keV γ射线照射时,Si-APD的闪烁产光量为70000 ph/MeV。闪烁衰减时间为ce掺杂石榴石材料的典型值,约为100ns。
{"title":"Scintillation properties of ceramic Ce-doped Gd3(Ga,Al)5O12","authors":"T. Yanagida, Y. Fujimoto, H. Yagi, T. Yanagitani","doi":"10.1109/NSSMIC.2013.6829666","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829666","url":null,"abstract":"Ceramic Ce 0.1% doped Gd<sub>3</sub>(Ga,Al)<sub>5</sub>O<sub>12</sub> scintillator fabricated by Konoshima Chemical was evaluated. In X-ray induced radioluminescence, intense emission peak appeared around 530 nm. When <sup>137</sup>Cs 662 keV γ-ray was irradiated, scintillation light yield turned out to be 70000 ph/MeV by using Si-APD. Scintillation decay timewas a typical value of Ce-doped garnet materials, ~ 100 ns.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131044901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Preliminary investigation of imaging properties for sub-millimeter square pinholes 亚毫米方针孔成像特性的初步研究
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829173
D. Xia, Mi-Ae Park, S. Moore, S. Metzler
Recently, a square-pinhole collimator has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the fields of view (FOVs) in transverse and axial directions become separable. In this work, we have conducted sensitivity and FOV experiments for eighteen fabricated platinum/iridium(Pt/Ir) inserts with sub-millimeter square-apertures. A sinqθ fit to the experimental sensitivity has been performed for these inserts. The mean (standard deviation) of fitted sensitivity exponents (q) and effective diameters (d) are 10.7 (1.3) and 0.35 mm (0.02 mm), which are close to the values obtained from the simulated sensitivity data generated using the geometric parameters of the designed inserts. From projections of the FOV on the detector, we have measured the acceptance angles in the transverse and axial directions. The measured mean (standard deviation) of transverse and axial half-acceptances are 17.33° (0.21°) and 15.03°(0.23°), which are in good agreement with the designed values (17.13° and 14.93°). These results show that the physical properties of the fabricated inserts with sub-millimeter aperture size match our design well.
近年来,人们提出了一种用于SPECT成像的方形针孔准直器,它可以有效地将投影平铺到探测器上,并且可以分离横向和轴向的视场。在这项工作中,我们对18个制造的亚毫米方形孔径铂/铱(Pt/Ir)插入物进行了灵敏度和视场实验。对这些插片进行了与实验灵敏度的sinqθ拟合。拟合的灵敏度指数(q)和有效直径(d)的均值(标准差)分别为10.7(1.3)和0.35 mm (0.02 mm),与利用设计刀片几何参数生成的模拟灵敏度数据得到的值接近。根据视场在探测器上的投影,我们测量了横向和轴向的接收角。实测的横向和轴向半接受度均值(标准差)分别为17.33°(0.21°)和15.03°(0.23°),与设计值(17.13°和14.93°)吻合较好。结果表明,制备的亚毫米孔径刀片的物理性能符合设计要求。
{"title":"Preliminary investigation of imaging properties for sub-millimeter square pinholes","authors":"D. Xia, Mi-Ae Park, S. Moore, S. Metzler","doi":"10.1109/NSSMIC.2013.6829173","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829173","url":null,"abstract":"Recently, a square-pinhole collimator has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the fields of view (FOVs) in transverse and axial directions become separable. In this work, we have conducted sensitivity and FOV experiments for eighteen fabricated platinum/iridium(Pt/Ir) inserts with sub-millimeter square-apertures. A sinqθ fit to the experimental sensitivity has been performed for these inserts. The mean (standard deviation) of fitted sensitivity exponents (q) and effective diameters (d) are 10.7 (1.3) and 0.35 mm (0.02 mm), which are close to the values obtained from the simulated sensitivity data generated using the geometric parameters of the designed inserts. From projections of the FOV on the detector, we have measured the acceptance angles in the transverse and axial directions. The measured mean (standard deviation) of transverse and axial half-acceptances are 17.33° (0.21°) and 15.03°(0.23°), which are in good agreement with the designed values (17.13° and 14.93°). These results show that the physical properties of the fabricated inserts with sub-millimeter aperture size match our design well.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130932791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Radiation response of transition metals-doped lithium aluminate crystals 过渡金属掺杂铝酸锂晶体的辐射响应
Pub Date : 2013-10-01 DOI: 10.1109/NSSMIC.2013.6829660
Y. Fujimoto, T. Yanagida, K. Kamada, J. Pejchal
Basic radiation response properties of lithium aluminate LiAlO2 crystals activated with transition metals like Ti, Mn and Cu were examined. When X-ray excited the crystals, intense emission peaks were observed at visible wavelength regions, they are ascribed to the Ti4+ charge transfer (Ti-doped), Mn2+ 3d5-3d5 (Mn-doped) and Cu+ 3d94s-3d10 (Cu-doped) transitions. The scintillation decay times were estimated to be about 1.8 μs (93 %) and 9.9 μs (7 %) for the Ti-doped crystal, 310 μs (96 %) and 2220 μs (4 %) for Mn-doped one, and 3.6 μs (52 %) and 19.6 μs (48 %) for Cu-doped one, respectively. In the 252Cf neutron irradiated pulse height spectra, Ti- and Cu- doped crystals showed higher light yield in comparison to that of GS20 commercial scintillator.
研究了过渡金属Ti、Mn和Cu活化铝酸锂LiAlO2晶体的基本辐射响应特性。当x射线激发晶体时,在可见波长区域观察到强烈的发射峰,它们归因于Ti4+电荷转移(ti掺杂),Mn2+ 3d5-3d5 (mn掺杂)和Cu+ 3d94s-3d10 (Cu掺杂)跃迁。结果表明,ti掺杂晶体的闪烁衰减时间分别为1.8 μs(93%)和9.9 μs (7%), mn掺杂晶体为310 μs(96%)和2220 μs (4%), cu掺杂晶体为3.6 μs(52%)和19.6 μs(48%)。在252Cf中子辐照的脉冲高度谱中,掺Ti和Cu晶体比GS20商用闪烁体表现出更高的光产率。
{"title":"Radiation response of transition metals-doped lithium aluminate crystals","authors":"Y. Fujimoto, T. Yanagida, K. Kamada, J. Pejchal","doi":"10.1109/NSSMIC.2013.6829660","DOIUrl":"https://doi.org/10.1109/NSSMIC.2013.6829660","url":null,"abstract":"Basic radiation response properties of lithium aluminate LiAlO<sub>2</sub> crystals activated with transition metals like Ti, Mn and Cu were examined. When X-ray excited the crystals, intense emission peaks were observed at visible wavelength regions, they are ascribed to the Ti<sup>4+</sup> charge transfer (Ti-doped), Mn<sup>2+</sup> 3d<sup>5</sup>-3d<sup>5</sup> (Mn-doped) and Cu<sup>+</sup> 3d<sup>9</sup>4s-3d<sup>10</sup> (Cu-doped) transitions. The scintillation decay times were estimated to be about 1.8 μs (93 %) and 9.9 μs (7 %) for the Ti-doped crystal, 310 μs (96 %) and 2220 μs (4 %) for Mn-doped one, and 3.6 μs (52 %) and 19.6 μs (48 %) for Cu-doped one, respectively. In the <sup>252</sup>Cf neutron irradiated pulse height spectra, Ti- and Cu- doped crystals showed higher light yield in comparison to that of GS20 commercial scintillator.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130980357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
期刊
2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1