首页 > 最新文献

Ukrainian Metrological Journal最新文献

英文 中文
Analysis of the temperature component of the combined standard uncertainty of the refractive index according to the test data of the control system for meteorological parameters developed for the Lyptsi geodetic polygon 根据Lyptsi大地多边形气象参数控制系统的测试数据,分析了折射率组合标准不确定度的温度分量
IF 0.1 Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250411
P. Neyezhmakov, A. Prokopov, Tatiana Panasenko, A. Shloma
The National Scientific Centre “Institute of Metrology” is actively involved in the implementation of a number of international projects under the EMPIR programme. One of such joint projects is the EMPIR 18SIB01 GeoMetre research project “Large-scale dimensional measurements for geodesy”. The overall goal of the project is to ensure traceability of length measurements – from the measurement standard of the unit of length to long distances typical for geodetic measurements. As a result of the project, it is necessary to provide length measurements of at least 5 km with an expanded uncertainty of no more than 1 mm. The main task of the NSC “Institute of Metrology” within this project is the development, research and practical implementation of methods and means of accounting for the influence of the earth’s atmosphere on the results of measurements of long distances in geodesy, carried out using electromagnetic waves in the optical range. When performing the section Task 1.4 of the project, new methods of highly accurate determination of the mean integral refractive index of air, used as a correction taking into account the influence of the atmosphere on the measurement results, are justified. Requirements for the accuracy of measurements of meteorological parameters at discrete points of the baseline are formulated, which are necessary to determine the mean integral refractive index. That is, the requirements for the metrological characteristics of temperature, pressure and humidity sensors are determined. The article discusses the results of the development, manufacture and testing of the sensors for temperature measurement. It is shown that the created sensors meet the requirements of the GeoMetre project.
国家科学中心“计量研究所”积极参与实施环境管理信息系统方案下的一些国际项目。其中一个联合项目是EMPIR 18SIB01 GeoMetre研究项目“大地测量的大规模尺寸测量”。该项目的总体目标是确保长度测量的可追溯性——从长度单位的测量标准到大地测量的典型长距离。由于该项目,有必要提供至少5公里的长度测量,扩展不确定度不超过1毫米。NSC“计量研究所”在该项目中的主要任务是开发、研究和实际实施利用光学范围内的电磁波进行的大地测量中地球大气层对远距离测量结果的影响的方法和手段。在执行该项目的任务1.4部分时,有理由采用高精度测定空气平均积分折射率的新方法,将大气对测量结果的影响作为校正。制定了基线离散点气象参数测量精度的要求,这是确定平均积分折射率所必需的。也就是说,确定了温度、压力和湿度传感器的计量特性要求。本文讨论了温度测量传感器的开发、制造和测试结果。结果表明,所建立的传感器满足GeoMetre项目的要求。
{"title":"Analysis of the temperature component of the combined standard uncertainty of the refractive index according to the test data of the control system for meteorological parameters developed for the Lyptsi geodetic polygon","authors":"P. Neyezhmakov, A. Prokopov, Tatiana Panasenko, A. Shloma","doi":"10.24027/2306-7039.4.2021.250411","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250411","url":null,"abstract":"The National Scientific Centre “Institute of Metrology” is actively involved in the implementation of a number of international projects under the EMPIR programme. One of such joint projects is the EMPIR 18SIB01 GeoMetre research project “Large-scale dimensional measurements for geodesy”. The overall goal of the project is to ensure traceability of length measurements – from the measurement standard of the unit of length to long distances typical for geodetic measurements. As a result of the project, it is necessary to provide length measurements of at least 5 km with an expanded uncertainty of no more than 1 mm. \u0000The main task of the NSC “Institute of Metrology” within this project is the development, research and practical implementation of methods and means of accounting for the influence of the earth’s atmosphere on the results of measurements of long distances in geodesy, carried out using electromagnetic waves in the optical range. \u0000When performing the section Task 1.4 of the project, new methods of highly accurate determination of the mean integral refractive index of air, used as a correction taking into account the influence of the atmosphere on the measurement results, are justified. Requirements for the accuracy of measurements of meteorological parameters at discrete points of the baseline are formulated, which are necessary to determine the mean integral refractive index. That is, the requirements for the metrological characteristics of temperature, pressure and humidity sensors are determined. \u0000The article discusses the results of the development, manufacture and testing of the sensors for temperature measurement. It is shown that the created sensors meet the requirements of the GeoMetre project.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48570289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Informational uncertainty of measuring instruments 测量仪器的信息不确定度
IF 0.1 Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250399
Gennadii Manko, Elena Titova
Recently, there has been a revival of interest in the use of the information approach in the theory of measurements. Unlike the traditional approach, information theory does not evaluate error or uncertainty, but entropy and the amount of information. This article analyzes a number of recent publications that develop ideas for the information approach. The limitations and disadvantages of both the entropy approach and the concept of uncertainty are indicated. As a compromise solution, it is proposed to use a criterion based on the Bongard’s uncertainty and useful information. The concept of information uncertainty is proposed, which is estimated by the amount of negative useful information, that is, misinformation introduced by the measuring instrument. Some methods for calculating information uncertainty are described. The problems of using the uncertainty approach are noted. This approach does not imply the use of such a generalized characteristic of measuring instruments as an accuracy class. The article proposes an analogue of the accuracy class in the form of relative informational uncertainty, expressed as a percentage. This will make it possible to evaluate the quality of the measuring instrument by a single parameter, the calculation of which requires a minimum of computational operations.
最近,人们对在测量理论中使用信息方法重新产生了兴趣。与传统方法不同,信息论不评估误差或不确定性,而是熵和信息量。本文分析了一些最近的出版物,这些出版物提出了信息方法的思想。指出了熵法和不确定性概念的局限性和缺点。作为一种折衷的解决方案,提出了一种基于邦加德不确定性和有用信息的准则。提出了信息不确定度的概念,通过测量仪器引入的负有用信息即错误信息的数量来估计信息不确定度。介绍了计算信息不确定性的几种方法。指出了使用不确定度方法的问题。这种方法并不意味着使用测量仪器的这种广义特性作为精度等级。本文以相对信息不确定性的形式提出了准确度类的类比,以百分比表示。这将使通过单个参数评估测量仪器的质量成为可能,其计算需要最少的计算操作。
{"title":"Informational uncertainty of measuring instruments","authors":"Gennadii Manko, Elena Titova","doi":"10.24027/2306-7039.4.2021.250399","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250399","url":null,"abstract":"Recently, there has been a revival of interest in the use of the information approach in the theory of measurements. Unlike the traditional approach, information theory does not evaluate error or uncertainty, but entropy and the amount of information. This article analyzes a number of recent publications that develop ideas for the information approach. The limitations and disadvantages of both the entropy approach and the concept of uncertainty are indicated. As a compromise solution, it is proposed to use a criterion based on the Bongard’s uncertainty and useful information. The concept of information uncertainty is proposed, which is estimated by the amount of negative useful information, that is, misinformation introduced by the measuring instrument. Some methods for calculating information uncertainty are described. \u0000The problems of using the uncertainty approach are noted. This approach does not imply the use of such a generalized characteristic of measuring instruments as an accuracy class. The article proposes an analogue of the accuracy class in the form of relative informational uncertainty, expressed as a percentage. This will make it possible to evaluate the quality of the measuring instrument by a single parameter, the calculation of which requires a minimum of computational operations.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"68826998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigation of photobiological safety of blue light of LED image projector of household use 家用LED图像投影仪蓝光的光生物安全性研究
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241285
Oleksandr Pitiakov, P. Neyezhmakov, S. Shpak, Svitlana Kyslytsia, G. Kozhushko
Abstract Light emitted in the wavelength range of 400–500 nm causes a very significant photochemical effect on the retina. At certain doses of blue light energy can cause damage to the retina, so the study of the safety of blue light projectors used in domestic conditions is an urgent task. The aim of this work is to study the photobiological safety of light image projectors with light emitting diodes. The paper analyzes the requirements for photobiological safety of tube systems and methods for assessing the danger of blue light of projectors that use LED light sources. The information is provided on the equipment for measurement of spectroradiometric and photometric parameters of beams of projectors, as well as features of radiance and irradiance measurement of lamp systems in which lens optics is used. The results of research of photobiological danger levels of blue light of image projectors intended for use in household conditions are presented. It is shown that at a distance of 1 m from the projector (the distance for which the level of photobiological safety of blue light is normalized), the investigated type of projector belongs to the risk group RG1 (insignificant risk). When the distance is reduced to 0.5 m and 0.2 m, the risk of blue light increases to the RG2 group (medium risk). The features of the requirements for photobiological safety of blue light of image projectors used in everyday life, educational institutions and in other conditions are analyzed. In particular, the risk group at a distance of 1 m from the collimator lens should not exceed RG1, and it is recommended to put an additional label on the projector indicating the risk group RG1 and mark this information in the user manual. Conclusions are made on the compliance of the studied low-power image projectors with the safety conditions of blue light, established by the international standard IEC 62471-5 (Photobiological Safety of Lamps and Lamp Systems – Part 5 Image Projectors).
400 - 500nm波长范围内发出的光对视网膜产生非常显著的光化学效应。在一定剂量的蓝光能量下会对视网膜造成损伤,因此研究国内条件下使用的蓝光投影仪的安全性是一项紧迫的任务。本工作的目的是研究发光二极管光像投影仪的光生物学安全性。本文分析了灯管系统光生物安全性的要求和LED光源投影机蓝光危险性的评估方法。提供了用于测量投影仪光束的光谱辐射和光度参数的设备的信息,以及使用透镜光学的灯系统的辐射和辐照度测量的特征。介绍了家用放映机蓝光光生物学危险水平的研究结果。结果表明,在距离投影机1 m的距离(蓝光光生物安全水平归一化的距离),所研究类型的投影机属于RG1(不显著风险)风险组。当距离减小到0.5 m和0.2 m时,蓝光风险增加至RG2组(中等风险)。分析了日常生活、教育机构和其他场合使用的放映机蓝光光生物安全要求的特点。特别是距准直镜1 m处的风险组不应超过RG1,建议在投影仪上额外标注风险组RG1,并在用户手册中标注。根据国际标准IEC 62471-5(灯和灯系统的光生物安全-第5部分图像投影仪)建立的蓝光安全条件,得出了所研究的低功率图像投影仪符合的结论。
{"title":"Investigation of photobiological safety of blue light of LED image projector of household use","authors":"Oleksandr Pitiakov, P. Neyezhmakov, S. Shpak, Svitlana Kyslytsia, G. Kozhushko","doi":"10.24027/2306-7039.3.2021.241285","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241285","url":null,"abstract":"Abstract \u0000Light emitted in the wavelength range of 400–500 nm causes a very significant photochemical effect on the retina. At certain doses of blue light energy can cause damage to the retina, so the study of the safety of blue light projectors used in domestic conditions is an urgent task. The aim of this work is to study the photobiological safety of light image projectors with light emitting diodes. The paper analyzes the requirements for photobiological safety of tube systems and methods for assessing the danger of blue light of projectors that use LED light sources. The information is provided on the equipment for measurement of spectroradiometric and photometric parameters of beams of projectors, as well as features of radiance and irradiance measurement of lamp systems in which lens optics is used. \u0000The results of research of photobiological danger levels of blue light of image projectors intended for use in household conditions are presented. It is shown that at a distance of 1 m from the projector (the distance for which the level of photobiological safety of blue light is normalized), the investigated type of projector belongs to the risk group RG1 (insignificant risk). When the distance is reduced to 0.5 m and 0.2 m, the risk of blue light increases to the RG2 group (medium risk). \u0000The features of the requirements for photobiological safety of blue light of image projectors used in everyday life, educational institutions and in other conditions are analyzed. In particular, the risk group at a distance of 1 m from the collimator lens should not exceed RG1, and it is recommended to put an additional label on the projector indicating the risk group RG1 and mark this information in the user manual. \u0000Conclusions are made on the compliance of the studied low-power image projectors with the safety conditions of blue light, established by the international standard IEC 62471-5 (Photobiological Safety of Lamps and Lamp Systems – Part 5 Image Projectors).","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46355118","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development, research and optimization of weight measuring system 称重系统的开发、研究与优化
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241640
N. Koshevoy, G. Cherepashchuk, Yevhen Kalashnikov, O. Zabolotnyi, Vitalii P. Siroklyn
The main task of the research is to improve technical and economic indicators of weight measuring system and to increase the efficiency of its research on the basis of cost-optimal planning of experiments. A system with a measuring tray has been developed, and it is different from existing systems with a possibility to control inclination angle of a tray, moisture content and temperature of a bulk substance, what provides better accuracy of mass measurement. The researches of weight measuring system were performed using the following methods of cost-optimal experiment planning: taboo search, particle swarm method, exhaustive search, Gray code based method. It gave possibility to reduce cost of implementing the experiment. To perform the research of weight measuring system, a plan of a full-factor experiment was selected, which was optimized for the cost of its implementation by using a method based on the Gray code. In the result of research, mathematical models in coded and natural values of factors were obtained. They characterize the dependence of the measurement acceptable error on such indicators as the angle of the measuring tray, the humidity of the bulk material, the coefficient of friction of the bulk material in motion. Using a mathematical model, rational values of the design parameters of the weight measuring system were obtained, which provide high accuracy (measurement acceptable error does not exceed 0.20%): the angle of the weight measuring tray α = 41.9°; humidity of loose material W = 14%; the coefficient of friction of the bulk material in motion fd  = 0.70. The developed weight measuring system can be widely used for dosing of bulk materials in various technological productions.
研究的主要任务是在实验成本最优规划的基础上,改进称重系统的技术经济指标,提高其研究效率。开发了一种带有测量盘的系统,它不同于现有的系统,可以控制托盘的倾角,散装物质的水分含量和温度,从而提供更好的质量测量精度。采用禁忌搜索法、粒子群法、穷举搜索法和基于Gray码的方法对称重系统进行了成本最优实验规划。为降低实验实施成本提供了可能。为了对称重系统进行研究,选择了一个全因素实验方案,并采用基于格雷码的方法对其实施成本进行了优化。在研究结果中,得到了因子的编码值和自然值的数学模型。它们描述了测量可接受误差对诸如测量盘的角度、散装物料的湿度、散装物料在运动中的摩擦系数等指标的依赖性。利用数学模型,得到了测量精度高(测量可接受误差不超过0.20%)的称重系统设计参数的合理值:称重盘角度α = 41.9°;松散物料湿度W = 14%;运动中的大块物料的摩擦系数fd = 0.70。所研制的重量测量系统可广泛用于各种工艺生产中散装物料的计量。
{"title":"Development, research and optimization of weight measuring system","authors":"N. Koshevoy, G. Cherepashchuk, Yevhen Kalashnikov, O. Zabolotnyi, Vitalii P. Siroklyn","doi":"10.24027/2306-7039.3.2021.241640","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241640","url":null,"abstract":"The main task of the research is to improve technical and economic indicators of weight measuring system and to increase the efficiency of its research on the basis of cost-optimal planning of experiments. \u0000A system with a measuring tray has been developed, and it is different from existing systems with a possibility to control inclination angle of a tray, moisture content and temperature of a bulk substance, what provides better accuracy of mass measurement. \u0000The researches of weight measuring system were performed using the following methods of cost-optimal experiment planning: taboo search, particle swarm method, exhaustive search, Gray code based method. It gave possibility to reduce cost of implementing the experiment. \u0000To perform the research of weight measuring system, a plan of a full-factor experiment was selected, which was optimized for the cost of its implementation by using a method based on the Gray code. \u0000In the result of research, mathematical models in coded and natural values of factors were obtained. They characterize the dependence of the measurement acceptable error on such indicators as the angle of the measuring tray, the humidity of the bulk material, the coefficient of friction of the bulk material in motion. Using a mathematical model, rational values of the design parameters of the weight measuring system were obtained, which provide high accuracy (measurement acceptable error does not exceed 0.20%): the angle of the weight measuring tray α = 41.9°; humidity of loose material W = 14%; the coefficient of friction of the bulk material in motion fd  = 0.70. \u0000The developed weight measuring system can be widely used for dosing of bulk materials in various technological productions.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"68826982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Comparative research of quality indicators of measuring instruments: practical aspects 测量仪器质量指标的比较研究:实用方面
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241620
O. Velychko, T. Gordiyenko
The main purpose of modern measuring instrument MI is to perform accurate and reliable measurements in order to obtain complete and reliable measurement information. The MI must be of proper quality, which must be reliably assessed. For technical means, traditional quality indicators have been established, some of which are common to MI. The metrological characteristic is unique to a MI and can be considered one of the most important of MI indicators. The quality of MI is characterized by a certain system of quality indicators. Depending on MI group, the system of quality indicators can differ. The target indicators are specific for each type of product. These indicators require additional analysis. The main metrological characteristics should be referred to the target indicators of MI. For some MI categories, additional indicators can be established, and for others, they are excluded. The methodology of evaluation of MI quality indicators and algorithm of its realization are offered. The digital multimeters as category of MI have been selected for practical comparative evaluation of MI quality indicators. The ten indicators for this category of MI have been refined. Comparative expert evaluation of quality indicators of 12 multimeters was carried out with the involvement of a group of 34 metrology experts. The weight of each of the 10 selected MI quality indicators was determined. The results of expert evaluation of multimeter are presented.
现代测量仪器MI的主要目的是进行准确可靠的测量,以获得完整可靠的测量信息。MI必须具有适当的质量,并且必须可靠地进行评估。在技术手段上,已经建立了传统的质量指标,其中一些是MI所共有的。计量特性是MI所独有的,可以认为是MI最重要的指标之一。机械工程的质量具有一定的质量指标体系。根据MI组的不同,质量指标体系可能有所不同。每种产品的目标指标都是特定的。这些指标需要进一步分析。主要计量特征参照MI的目标指标。对于MI的某些类别,可以建立额外的指标,对于其他类别,可以排除。给出了机械制造质量指标的评价方法及其实现算法。选择数字万用表作为智能仪表的类别,对智能仪表的质量指标进行了实际比较评价。这一类MI的10个指标已加以改进。在34名计量专家的参与下,对12个万用表的质量指标进行了比较专家评价。确定10个选定的MI质量指标的权重。介绍了专家对万用表的评价结果。
{"title":"Comparative research of quality indicators of measuring instruments: practical aspects","authors":"O. Velychko, T. Gordiyenko","doi":"10.24027/2306-7039.3.2021.241620","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241620","url":null,"abstract":"The main purpose of modern measuring instrument MI is to perform accurate and reliable measurements in order to obtain complete and reliable measurement information. The MI must be of proper quality, which must be reliably assessed. For technical means, traditional quality indicators have been established, some of which are common to MI. The metrological characteristic is unique to a MI and can be considered one of the most important of MI indicators. \u0000The quality of MI is characterized by a certain system of quality indicators. Depending on MI group, the system of quality indicators can differ. The target indicators are specific for each type of product. These indicators require additional analysis. The main metrological characteristics should be referred to the target indicators of MI. For some MI categories, additional indicators can be established, and for others, they are excluded. \u0000The methodology of evaluation of MI quality indicators and algorithm of its realization are offered. The digital multimeters as category of MI have been selected for practical comparative evaluation of MI quality indicators. The ten indicators for this category of MI have been refined. Comparative expert evaluation of quality indicators of 12 multimeters was carried out with the involvement of a group of 34 metrology experts. The weight of each of the 10 selected MI quality indicators was determined. The results of expert evaluation of multimeter are presented.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44967337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal data processing in the ballistic laser gravimeter under the effect of correlated interference 相关干涉作用下弹道激光重力仪数据的优化处理
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241522
Anatolii Omelchenko, O. Vinnichenko, P. Neyezhmakov, Oleksii Fedorov, V. Bolyuh
Abstract In order to develop optimal data processing algorithms in ballistic laser gravimeters under the effect of correlated interference, the method of generalized least squares is applied. In this case, to describe the interference, a mathematical model of the autoregression process is used, for which the inverse correlation matrix has a band type and is expressed through the values of the autoregression coefficients. To convert the “path-time” data from the output of the coincidence circuit of ballistic laser gravimeters to a process uniform in time, their local quadratic interpolation is used. Algorithms for data processing in a ballistic gravimeter, developed on the basis of a method of weighted least squares using orthogonal Hahn polynomials, are considered. To implement a symmetric measurement method, the symmetric Hahn polynomials, characterized by one parameter, are used. The method of mathematical modelling is used to study the gain in the accuracy of measuring the gravitational acceleration by the synthesized algorithms in comparison with the algorithm based on the method of least squares. It is shown that auto seismic interference in ballistic laser gravimeters with a symmetric measurement method can be significantly reduced by using a mathematical model of the second-order autoregressive process in the method of generalized least squares. A comparative analysis of the characteristics of the algorithms developed using the method of generalized least squares, the method of weighted least squares and the method of ordinary least squares is carried out.
摘要为了开发弹道激光重力仪在相关干扰作用下的最优数据处理算法,应用了广义最小二乘法。在这种情况下,为了描述干扰,使用自回归过程的数学模型,其中逆相关矩阵具有带型,并且通过自回归系数的值来表示。为了将弹道激光重力仪重合电路输出的“路径-时间”数据转换为时间均匀的过程,使用了它们的局部二次插值。考虑了基于正交Hahn多项式加权最小二乘法开发的弹道重力仪数据处理算法。为了实现对称测量方法,使用了以一个参数为特征的对称哈恩多项式。采用数学建模方法,与基于最小二乘法的算法进行比较,研究了合成算法在测量重力加速度精度方面的增益。结果表明,利用广义最小二乘法中的二阶自回归过程数学模型,可以显著降低对称测量弹道激光重力仪中的自地震干扰。比较分析了用广义最小二乘法、加权最小二乘法和普通最小二乘法开发的算法的特点。
{"title":"Optimal data processing in the ballistic laser gravimeter under the effect of correlated interference","authors":"Anatolii Omelchenko, O. Vinnichenko, P. Neyezhmakov, Oleksii Fedorov, V. Bolyuh","doi":"10.24027/2306-7039.3.2021.241522","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241522","url":null,"abstract":"Abstract \u0000In order to develop optimal data processing algorithms in ballistic laser gravimeters under the effect of correlated interference, the method of generalized least squares is applied. In this case, to describe the interference, a mathematical model of the autoregression process is used, for which the inverse correlation matrix has a band type and is expressed through the values of the autoregression coefficients. To convert the “path-time” data from the output of the coincidence circuit of ballistic laser gravimeters to a process uniform in time, their local quadratic interpolation is used. \u0000Algorithms for data processing in a ballistic gravimeter, developed on the basis of a method of weighted least squares using orthogonal Hahn polynomials, are considered. To implement a symmetric measurement method, the symmetric Hahn polynomials, characterized by one parameter, are used. \u0000The method of mathematical modelling is used to study the gain in the accuracy of measuring the gravitational acceleration by the synthesized algorithms in comparison with the algorithm based on the method of least squares. It is shown that auto seismic interference in ballistic laser gravimeters with a symmetric measurement method can be significantly reduced by using a mathematical model of the second-order autoregressive process in the method of generalized least squares. A comparative analysis of the characteristics of the algorithms developed using the method of generalized least squares, the method of weighted least squares and the method of ordinary least squares is carried out.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42569209","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Research of metrological capabilities of digital (DDS- and Trueform-) generators 数字(DDS-和Trueform-)发生器计量性能的研究
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241500
Y. Pavlenko, S. Kirienko, V. Ogar, Olena Vаsileva
Abstract One of the fundamental improvements of the measurement standard of frequency deviation of frequency-modulated oscillations was the replacement of analog frequency-modulated generators used in DETU 09-03-95 with digital ones based on the principle of direct digital synthesis (DDS) and its next version of Trueform technology. These generators have wider ranges of frequency deviation and modulation frequencies than analog ones, but nonlinear distortion laws of the frequency modulation are not standardized. The subject of the article is the development of methods and research of these generators and frequency-modulated signals generated by them for nonlinear distortions, accompanying amplitude modulation, frequency noise. Three methods were used in the study: direct measurement; “combination frequencies” and “frequency shift”. The experiment was performed using several measurement methods, which allowed to estimate very small values of nonlinear distortion. Methods were developed and experimental estimations of concomitant amplitude modulation of DDS-generators (in frequency modulation mode), as well as their frequency noise level, were performed. An experimental evaluation of the capabilities of the analog-digital demodulator of the R&S FSL6 spectrum analyzer with the K7 option was performed, its high linearity was shown, its capabilities with respect to the frequency ranges of carrier oscillations and frequency deviation were evaluated. The research results provide a basis for the method of calibration of DDS-generators and demodulator of spectrum analyzers with the K7 option in those ranges where their parameters are not normalized (at direct current up to 8 MHz and F up to 500 kHz).
摘要调频振荡频率偏差测量标准的一个根本改进是,基于直接数字合成(DDS)原理及其下一版本的Trueform技术,用数字发生器取代了DETU 09-03-95中使用的模拟调频发生器。这些发生器具有比模拟发生器更宽的频率偏差和调制频率范围,但频率调制的非线性失真规律并没有标准化。本文的主题是开发这些发生器的方法和研究,以及由它们产生的用于非线性失真、伴随的幅度调制和频率噪声的调频信号。研究中使用了三种方法:直接测量;“组合频率”和“频移”。实验是使用几种测量方法进行的,这些方法可以估计非常小的非线性失真值。开发了方法,并对DDS发生器(在频率调制模式下)的伴随幅度调制及其频率噪声水平进行了实验估计。对具有K7选项的R&S FSL6频谱分析仪的模数解调器的性能进行了实验评估,显示了其高线性,并评估了其对载波振荡和频率偏差的频率范围的能力。研究结果为在参数未归一化的范围内(直流高达8MHz,F高达500kHz)使用K7选项校准频谱分析仪的DDS发生器和解调器的方法提供了基础。
{"title":"Research of metrological capabilities of digital (DDS- and Trueform-) generators","authors":"Y. Pavlenko, S. Kirienko, V. Ogar, Olena Vаsileva","doi":"10.24027/2306-7039.3.2021.241500","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241500","url":null,"abstract":"Abstract \u0000One of the fundamental improvements of the measurement standard of frequency deviation of frequency-modulated oscillations was the replacement of analog frequency-modulated generators used in DETU 09-03-95 with digital ones based on the principle of direct digital synthesis (DDS) and its next version of Trueform technology. These generators have wider ranges of frequency deviation and modulation frequencies than analog ones, but nonlinear distortion laws of the frequency modulation are not standardized. \u0000The subject of the article is the development of methods and research of these generators and frequency-modulated signals generated by them for nonlinear distortions, accompanying amplitude modulation, frequency noise. Three methods were used in the study: direct measurement; “combination frequencies” and “frequency shift”. The experiment was performed using several measurement methods, which allowed to estimate very small values of nonlinear distortion. Methods were developed and experimental estimations of concomitant amplitude modulation of DDS-generators (in frequency modulation mode), as well as their frequency noise level, were performed. An experimental evaluation of the capabilities of the analog-digital demodulator of the R&S FSL6 spectrum analyzer with the K7 option was performed, its high linearity was shown, its capabilities with respect to the frequency ranges of carrier oscillations and frequency deviation were evaluated. The research results provide a basis for the method of calibration of DDS-generators and demodulator of spectrum analyzers with the K7 option in those ranges where their parameters are not normalized (at direct current up to 8 MHz and F up to 500 kHz).","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44825708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Metrological support of maintenance by the technical state of communication means 通过通信手段的技术状态为维护提供计量支持
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241573
Yu. Myroshnychenko
Modern and prospective communication means are among the most knowledge-driven, high-tech types of industrial products, which are subject to enhanced requirements for quality and efficiency of application. The effective functioning of modern communication means is provided by built-in software, including metrological support. In this paper, we consider the specifics of metrological maintenance of large-scale communication facilities (tens and hundreds of thousands of elements) consisting of separate subunits, the serviceability, maintenance, and recovery of which can be performed autonomously. It is proposed to enhance the efficiency of the by-state-maintenance (also called maintenance by the technical state) by accounting for the specifics of metrological support, establishing an optimal sequence of operations, selecting the measuring instruments in accordance with relevant requirements. To do this, one has to use a combined indicator composed of individual parameters of the tests and the probability of their preferred choice. This allows to assess the technical condition of the communication means with a given probability during a minimal time. In addition, one can estimate the time of maintenance, taking into account the metrological reliability and the probability of correct evaluation of the result of checking the parameters by the measuring instruments. The order of implementation of the obtained results is formalized in the form of an algorithm and an example of their realization is presented.
现代和前瞻性的通信手段是最受知识驱动的高科技工业产品,对应用的质量和效率有更高的要求。包括计量支持在内的内置软件提供了现代通信手段的有效功能。在本文中,我们考虑了由独立子单元组成的大型通信设施(数万个元件)的计量维护的细节,其可用性、维护和恢复可以自主执行。建议通过考虑计量支持的具体情况,建立最佳操作顺序,根据相关要求选择测量仪器,来提高国家维护(也称为技术国家维护)的效率。要做到这一点,必须使用一个由测试的单个参数和他们首选的概率组成的组合指标。这允许在最短的时间内以给定的概率来评估通信装置的技术条件。此外,可以估计维护时间,同时考虑计量可靠性和测量仪器对参数检查结果进行正确评估的可能性。以算法的形式形式形式化了所获得结果的实现顺序,并给出了它们的实现示例。
{"title":"Metrological support of maintenance by the technical state of communication means","authors":"Yu. Myroshnychenko","doi":"10.24027/2306-7039.3.2021.241573","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241573","url":null,"abstract":"Modern and prospective communication means are among the most knowledge-driven, high-tech types of industrial products, which are subject to enhanced requirements for quality and efficiency of application. The effective functioning of modern communication means is provided by built-in software, including metrological support. In this paper, we consider the specifics of metrological maintenance of large-scale communication facilities (tens and hundreds of thousands of elements) consisting of separate subunits, the serviceability, maintenance, and recovery of which can be performed autonomously. It is proposed to enhance the efficiency of the by-state-maintenance (also called maintenance by the technical state) by accounting for the specifics of metrological support, establishing an optimal sequence of operations, selecting the measuring instruments in accordance with relevant requirements. To do this, one has to use a combined indicator composed of individual parameters of the tests and the probability of their preferred choice. This allows to assess the technical condition of the communication means with a given probability during a minimal time. In addition, one can estimate the time of maintenance, taking into account the metrological reliability and the probability of correct evaluation of the result of checking the parameters by the measuring instruments. The order of implementation of the obtained results is formalized in the form of an algorithm and an example of their realization is presented.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43234299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Automated system for identification of data distribution laws by analysis of histogram proximity with sample reduction 用样本约简法分析直方图接近性来识别数据分布规律的自动化系统
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241627
Olha Oliynyk, Y. Taranenko
The error in the identification of the distribution law entails an incorrect assessment of other characteristics (standard deviation, kurtosis, antikurtosis, etc.). The article is devoted to the development of accessible and simple software products for solving problems of identifying distribution laws and determining the optimal size of a data sample. The paper describes a modified method for identifying the law of data distribution by visual analysis of the proximity of histograms with a reduction in the sample size with software implementation. The method allows choosing the most probable distribution law from a wide base of the set. The essence of the method consists in calculating the entropy coefficient and absolute entropy error for the initial and half data sample, determining the optimal method for processing the histogram using visual analysis of the proximity of histograms, and identifying the data distribution law. The experimental data processing model makes it possible to take into account the statistical properties of real data and can be applied to various arrays, and allows to reduce the sample size required for analysis. An automated system for identifying the laws of data distribution with a simple and intuitive interface has been developed. The results of the study on real data indicate an increase in the reliability of the identification of the data distribution law.
对分布规律的错误识别会导致对其他特征(标准差、峰度、反峰度等)的错误评估。本文致力于开发易于访问和简单的软件产品,以解决识别分布规律和确定数据样本的最佳大小的问题。本文描述了一种改进的方法,通过直观分析直方图的接近性来识别数据分布规律,并通过软件实现减少样本量。该方法允许从广泛的基数中选择最可能的分布规律。该方法的实质是计算初始数据样本和半数据样本的熵系数和绝对熵误差,利用直方图接近度的视觉分析确定处理直方图的最佳方法,识别数据分布规律。实验数据处理模型可以考虑到实际数据的统计特性,可以应用于各种阵列,并允许减少分析所需的样本量。开发了一种具有简单直观界面的自动识别数据分布规律的系统。对实际数据的研究结果表明,该方法提高了数据分布规律识别的可靠性。
{"title":"Automated system for identification of data distribution laws by analysis of histogram proximity with sample reduction","authors":"Olha Oliynyk, Y. Taranenko","doi":"10.24027/2306-7039.3.2021.241627","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241627","url":null,"abstract":"The error in the identification of the distribution law entails an incorrect assessment of other characteristics (standard deviation, kurtosis, antikurtosis, etc.). The article is devoted to the development of accessible and simple software products for solving problems of identifying distribution laws and determining the optimal size of a data sample. \u0000The paper describes a modified method for identifying the law of data distribution by visual analysis of the proximity of histograms with a reduction in the sample size with software implementation. The method allows choosing the most probable distribution law from a wide base of the set. The essence of the method consists in calculating the entropy coefficient and absolute entropy error for the initial and half data sample, determining the optimal method for processing the histogram using visual analysis of the proximity of histograms, and identifying the data distribution law. The experimental data processing model makes it possible to take into account the statistical properties of real data and can be applied to various arrays, and allows to reduce the sample size required for analysis. \u0000An automated system for identifying the laws of data distribution with a simple and intuitive interface has been developed. The results of the study on real data indicate an increase in the reliability of the identification of the data distribution law.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47595206","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Level gauges. Application features 水平指标。应用程序功能
IF 0.1 Pub Date : 2021-10-05 DOI: 10.24027/2306-7039.3.2021.241633
Gennadiy Narodnytskyi, Evgeniy Suhomlinov, Svitlana Tiupa, O. Marchenko
This paper considers various aspects of application of the most common types of level gauges – magnetostrictive, servo-driven, radar and reflex. Much attention is paid to accuracy of level gauges, expressed in error and uncertainty, including those referred to the legally regulated measuring instruments. Due to the fact that the most of the level gauges are installed on tanks, the requirements for them, given in the standards, and possible ways to improve the accuracy of level gauges installed on tanks have been analyzed. Methods of verification and calibration of level gauges are considered, including both verification on standard units using water, and carried out by the simulation method. The requirements for the metrological control of level gauges with moving parts are stated. It is shown that for verification of such level gauges, it is necessary to carry out measurements when the water moves both up and down. However, there is no need to take measurements, as in determining the variation, at the same points when the water moves up and when the water moves down. Some known caution is needed when using the results of the verification of level gauges by the simulation method. Especially big differences in the results of verification on the standard unit with water and the simulation method are observed for magnetostrictive level gauges. This difference is due to the fact that in these level gauges, the float slides along the pipe with a certain friction, and in the simulation method, the float moves by hand and its movement does not depend on friction.
本文考虑了最常见类型的液位计应用的各个方面——磁致伸缩、伺服驱动、雷达和反射。液位计的精度受到了极大的关注,用误差和不确定度表示,包括那些涉及法律规定的测量仪器的精度。由于大多数液位计都安装在储罐上,因此分析了标准中对液位计的要求,以及提高储罐上液位计精度的可能方法。考虑了液位计的检定和校准方法,包括在用水的标准装置上进行的检定和通过模拟方法进行的检定。阐述了带有移动部件的液位计的计量控制要求。结果表明,为了验证这种液位计,有必要在水上下移动时进行测量。然而,在确定变化时,不需要在水向上移动和向下移动的相同点进行测量。当使用模拟方法验证液位计的结果时,需要一些已知的注意事项。特别是磁致伸缩液位计在有水的标准装置上的验证结果和模拟方法存在很大差异。这种差异是由于在这些液位计中,浮子以一定的摩擦力沿着管道滑动,而在模拟方法中,浮子通过手动移动,其移动不取决于摩擦力。
{"title":"Level gauges. Application features","authors":"Gennadiy Narodnytskyi, Evgeniy Suhomlinov, Svitlana Tiupa, O. Marchenko","doi":"10.24027/2306-7039.3.2021.241633","DOIUrl":"https://doi.org/10.24027/2306-7039.3.2021.241633","url":null,"abstract":"This paper considers various aspects of application of the most common types of level gauges – magnetostrictive, servo-driven, radar and reflex. Much attention is paid to accuracy of level gauges, expressed in error and uncertainty, including those referred to the legally regulated measuring instruments. Due to the fact that the most of the level gauges are installed on tanks, the requirements for them, given in the standards, and possible ways to improve the accuracy of level gauges installed on tanks have been analyzed. Methods of verification and calibration of level gauges are considered, including both verification on standard units using water, and carried out by the simulation method. \u0000The requirements for the metrological control of level gauges with moving parts are stated. It is shown that for verification of such level gauges, it is necessary to carry out measurements when the water moves both up and down. However, there is no need to take measurements, as in determining the variation, at the same points when the water moves up and when the water moves down. \u0000Some known caution is needed when using the results of the verification of level gauges by the simulation method. Especially big differences in the results of verification on the standard unit with water and the simulation method are observed for magnetostrictive level gauges. \u0000This difference is due to the fact that in these level gauges, the float slides along the pipe with a certain friction, and in the simulation method, the float moves by hand and its movement does not depend on friction.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47542863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Ukrainian Metrological Journal
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1