Artificial Bee Colony based design optimization of a six-phase induction motor 基于人工蜂群的六相感应电机设计优化
Pratyush Das, S. N. Mahato
Artificial Bee Colony Algorithm (ABC) has been used to optimize the design of a six-phase induction motor (SPIM). Multi-objective function has been considered for optimization. Comparison of the optimum design using Artificial Bee Colony Algorithm with that of traditional design and Genetic Algorithm (GA) based optimum design has been presented, which shows that improved design can be achieved by Artificial Bee Colony technique of optimization. Comparison of the results obtained has been done to find the fittest method of optimization for the said purpose. Performances of the induction motor have been evaluated for each design effectively.
采用人工蜂群算法(ABC)对六相感应电动机(SPIM)进行优化设计。采用多目标函数进行优化。将人工蜂群算法的优化设计与传统设计和基于遗传算法的优化设计进行了比较,表明人工蜂群优化技术可以实现改进设计。并对所得结果进行了比较,以找出最适合的优化方法。对每一种设计都有效地评价了感应电机的性能。
{"title":"Artificial Bee Colony based design optimization of a six-phase induction motor","authors":"Pratyush Das, S. N. Mahato","doi":"10.1109/CIEC.2016.7513822","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513822","url":null,"abstract":"Artificial Bee Colony Algorithm (ABC) has been used to optimize the design of a six-phase induction motor (SPIM). Multi-objective function has been considered for optimization. Comparison of the optimum design using Artificial Bee Colony Algorithm with that of traditional design and Genetic Algorithm (GA) based optimum design has been presented, which shows that improved design can be achieved by Artificial Bee Colony technique of optimization. Comparison of the results obtained has been done to find the fittest method of optimization for the said purpose. Performances of the induction motor have been evaluated for each design effectively.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128229421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A unified approach for identification and control of electro-magnetic levitation system in delta domain 一种统一的三角域电磁悬浮系统辨识与控制方法
A. Mondal, P. Sarkar
This paper proposes a unified approach for identification and control of delta operator parameterized Electro-magnetic Levitation System (EMLS). Dynamic systems modelling with delta operator provide a unified framework in rapprochement between discrete-time dynamic models and its analog counterpart at fast sampling. Capitalizing this unique feature, the concept of time moment is recasted in delta operator formulation as delta time moment (DTM). These DTMs are then estimated from the input-output measurements taken from unknown plant to develop control law in an approximate model matching framework so that the compensated plant output follow a reference model output under an input excitation. The reference model is so parameterized in the complex delta domain that it embodies classical time, frequency and complex domain specifications and guarantee both stability and performance. Four different adaptive control law, i) Inverse control using DTM (ICDTM), ii) Pade Adapted Inverse control using DTM with error feedback (PICDTMEF), iii) Plant Delta Time Moment control scheme (PDTMC) and iv) Pade adapted Delta Time Moment control with error feedback (PDTMCEF) have been proposed to design control schemes for the EMLS. Simulation results show the effectiveness of the proposed methods.
提出了一种delta算子参数化电磁悬浮系统(EMLS)的统一辨识与控制方法。用delta算子对动态系统进行建模,为离散时间动态模型和快速采样时的模拟模型之间的联系提供了一个统一的框架。利用这一独特的特征,时间矩的概念在delta算子的表述中被重铸为delta时间矩(DTM)。然后根据未知对象的输入-输出测量值对这些dtm进行估计,从而在近似模型匹配框架中建立控制律,以便在输入激励下补偿的对象输出遵循参考模型输出。参考模型在复δ域参数化,既体现了经典的时间、频率和复域规范,又保证了稳定性和性能。提出了四种不同的自适应控制律,即i)基于DTM的逆控制(ICDTM), ii)基于DTM的带误差反馈的自适应逆控制(PICDTMEF), iii)植物增量时间矩控制方案(PDTMC)和iv)基于误差反馈的自适应增量时间矩控制(PDTMCEF)来设计EMLS的控制方案。仿真结果表明了所提方法的有效性。
{"title":"A unified approach for identification and control of electro-magnetic levitation system in delta domain","authors":"A. Mondal, P. Sarkar","doi":"10.1109/CIEC.2016.7513778","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513778","url":null,"abstract":"This paper proposes a unified approach for identification and control of delta operator parameterized Electro-magnetic Levitation System (EMLS). Dynamic systems modelling with delta operator provide a unified framework in rapprochement between discrete-time dynamic models and its analog counterpart at fast sampling. Capitalizing this unique feature, the concept of time moment is recasted in delta operator formulation as delta time moment (DTM). These DTMs are then estimated from the input-output measurements taken from unknown plant to develop control law in an approximate model matching framework so that the compensated plant output follow a reference model output under an input excitation. The reference model is so parameterized in the complex delta domain that it embodies classical time, frequency and complex domain specifications and guarantee both stability and performance. Four different adaptive control law, i) Inverse control using DTM (ICDTM), ii) Pade Adapted Inverse control using DTM with error feedback (PICDTMEF), iii) Plant Delta Time Moment control scheme (PDTMC) and iv) Pade adapted Delta Time Moment control with error feedback (PDTMCEF) have been proposed to design control schemes for the EMLS. Simulation results show the effectiveness of the proposed methods.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"101 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133948105","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Portable photoplethysmogram acquisition and analysis instrument 便携式光电容积图采集与分析仪器
S. Alam, Rajarshi Gupta
On-site measurement of physiological information can provide a quick assessment of patients' health condition. The paper illustrates a simple PPG acquisition and preliminary level analysis instrument using a laptop. A portable data acquisition system based on ATmega16 microcontroller was developed to collect 30 sec PPG data at 250 Hz sampling using USB interface. Based on the data, all the fiducial points were detected using first and second difference PPG. The software computes the heart rate, peak to peak time, stiffness index and crest time averaged over all cardiac cycles and displays them on the front panel of the laptop.
现场测量生理信息可以快速评估患者的健康状况。本文介绍了一种使用笔记本电脑的简单的PPG采集和初级水平分析仪器。研制了一种基于ATmega16单片机的便携式数据采集系统,通过USB接口采集250 Hz采样频率下的30秒PPG数据。在此基础上,利用一差和二差PPG检测所有基点。该软件计算出所有心脏周期的心率、峰值时间、僵硬指数和峰值时间的平均值,并显示在笔记本电脑的前面板上。
{"title":"Portable photoplethysmogram acquisition and analysis instrument","authors":"S. Alam, Rajarshi Gupta","doi":"10.1109/CIEC.2016.7513775","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513775","url":null,"abstract":"On-site measurement of physiological information can provide a quick assessment of patients' health condition. The paper illustrates a simple PPG acquisition and preliminary level analysis instrument using a laptop. A portable data acquisition system based on ATmega16 microcontroller was developed to collect 30 sec PPG data at 250 Hz sampling using USB interface. Based on the data, all the fiducial points were detected using first and second difference PPG. The software computes the heart rate, peak to peak time, stiffness index and crest time averaged over all cardiac cycles and displays them on the front panel of the laptop.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125831396","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Feature extraction and classification of woven fabric using optimized Haralick parameters: A rough set based approach 基于优化Haralick参数的机织织物特征提取与分类:基于粗糙集的方法
Jayanta K. Chandra, Madhumanti Majumdar, Sourish Sarkar
Classification of fabric samples into classes is highly required for automatic fabric inspection systems, as many of the fabric defects are defined relative to the fabric classes. The texture of the fabric surface is the best way to represent a fabric class, corresponding to which the statistical measures are the Haralick parameters. As all of the Haralick parameters are not responsible for fabric classification and there are no universal Haralick parameters for classifying all types of fabric samples, so it is necessary to determine a subset of Haralick parameters that gives best classification result for the fabric classes under consideration. This subset of Haralick parameters is termed as optimized Haralick parameters of the fabric classes under consideration, which has been determined by using the rough set theory. The developed system has been tested on TILDA database and its superiority with respect to the non-optimized Haralick parameters is established in terms of classification result and separability index.
织物自动检测系统非常需要对织物样品进行分类,因为许多织物缺陷都是根据织物类别来定义的。织物表面的纹理是表示织物类的最佳方式,与之相对应的统计度量是哈拉里克参数。由于并非所有的Haralick参数都对织物分类负责,也没有统一的Haralick参数对所有类型的织物样本进行分类,因此有必要确定Haralick参数的一个子集,使其对所考虑的织物类别给出最佳的分类结果。该Haralick参数子集称为所考虑的织物类的优化Haralick参数,该参数是用粗糙集理论确定的。在TILDA数据库上对所开发的系统进行了测试,从分类结果和可分性指标两方面证明了该系统相对于未优化的Haralick参数的优越性。
{"title":"Feature extraction and classification of woven fabric using optimized Haralick parameters: A rough set based approach","authors":"Jayanta K. Chandra, Madhumanti Majumdar, Sourish Sarkar","doi":"10.1109/CIEC.2016.7513748","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513748","url":null,"abstract":"Classification of fabric samples into classes is highly required for automatic fabric inspection systems, as many of the fabric defects are defined relative to the fabric classes. The texture of the fabric surface is the best way to represent a fabric class, corresponding to which the statistical measures are the Haralick parameters. As all of the Haralick parameters are not responsible for fabric classification and there are no universal Haralick parameters for classifying all types of fabric samples, so it is necessary to determine a subset of Haralick parameters that gives best classification result for the fabric classes under consideration. This subset of Haralick parameters is termed as optimized Haralick parameters of the fabric classes under consideration, which has been determined by using the rough set theory. The developed system has been tested on TILDA database and its superiority with respect to the non-optimized Haralick parameters is established in terms of classification result and separability index.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127066804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Modeling and simulation of a novel three phase discrete observer based on recurrence formula 基于递推公式的新型三相离散观测器建模与仿真
Ankith Vinayachandran, K. Selvajyothi
Design and analysis of a novel three phase discrete observer is proposed in this paper. A rotation matrix based on recurrence formula along with observer feedback matrix set for a particular frequency is used to formulate a structure such that accurate estimation is obtained for the designed frequency. This observer is used to filter out the switching noise percolating into the control loop by providing ripple free feedback variables in d-q control. Also this helps in achieving faster transient response in current control. Simulation of decoupled current control of a stand-alone three phase Inverter is done to evaluate the performance and feasibility of the proposed observer.
提出了一种新型三相离散观测器的设计与分析方法。利用基于递推公式的旋转矩阵和特定频率的观测器反馈矩阵集构成结构,从而对设计频率进行精确估计。该观测器通过在d-q控制中提供无纹波反馈变量来滤除渗透到控制回路中的开关噪声。这也有助于在电流控制中实现更快的瞬态响应。对独立三相逆变器的解耦电流控制进行了仿真,以评估所提出观测器的性能和可行性。
{"title":"Modeling and simulation of a novel three phase discrete observer based on recurrence formula","authors":"Ankith Vinayachandran, K. Selvajyothi","doi":"10.1109/CIEC.2016.7513750","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513750","url":null,"abstract":"Design and analysis of a novel three phase discrete observer is proposed in this paper. A rotation matrix based on recurrence formula along with observer feedback matrix set for a particular frequency is used to formulate a structure such that accurate estimation is obtained for the designed frequency. This observer is used to filter out the switching noise percolating into the control loop by providing ripple free feedback variables in d-q control. Also this helps in achieving faster transient response in current control. Simulation of decoupled current control of a stand-alone three phase Inverter is done to evaluate the performance and feasibility of the proposed observer.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121638568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
FPGA friendly fault detection technique for drive fed induction motor 驱动型异步电动机的FPGA友好故障检测技术
Parth Sarathi Panigrahy, Subhrajit Mitra, P. Konar, P. Chattopadhyay
FPGA based embedded system for continuous online monitoring has gained importance in recent years. The existing FPGA based methodologies rely on transient analysis, which unnecessarily gives undue stress to the motor. Also, FFT is used which consumes large resource in the hardware unit. In this paper a DWT based algorithm is designed and implemented in FPGA to detect Broken rotor bar fault using vibration signal at low loading condition at steady state. The main contribution of this work is considerable reduction of hardware resource by use of 2-length filter for DWT and RMS energy based decision block for fault detection. In addition, there is flexibility in extending the algorithm for multi-class fault detection by controlling the required frequency band of DWT.
近年来,基于FPGA的嵌入式连续在线监测系统越来越受到重视。现有的基于FPGA的方法依赖于瞬态分析,这给电机带来了不必要的压力。此外,FFT的使用消耗了大量的硬件资源。本文在FPGA上设计并实现了一种基于小波变换的转子断条故障检测算法,在稳态低负荷状态下利用振动信号检测断条故障。该工作的主要贡献是通过使用2长度滤波器进行DWT和基于RMS能量的决策块进行故障检测,大大减少了硬件资源。此外,通过控制小波变换所需的频带,可以灵活地将算法扩展到多类故障检测。
{"title":"FPGA friendly fault detection technique for drive fed induction motor","authors":"Parth Sarathi Panigrahy, Subhrajit Mitra, P. Konar, P. Chattopadhyay","doi":"10.1109/CIEC.2016.7513787","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513787","url":null,"abstract":"FPGA based embedded system for continuous online monitoring has gained importance in recent years. The existing FPGA based methodologies rely on transient analysis, which unnecessarily gives undue stress to the motor. Also, FFT is used which consumes large resource in the hardware unit. In this paper a DWT based algorithm is designed and implemented in FPGA to detect Broken rotor bar fault using vibration signal at low loading condition at steady state. The main contribution of this work is considerable reduction of hardware resource by use of 2-length filter for DWT and RMS energy based decision block for fault detection. In addition, there is flexibility in extending the algorithm for multi-class fault detection by controlling the required frequency band of DWT.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117321554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A novel strategy for determination of optimal sizing of PV-wind hybrid system 一种确定PV-wind混合系统最优尺寸的新策略
B. Tudu, K. Mandal, N. Chakraborty
A novel methodology for strategic selection of different components of PV-wind hybrid system is presented here. The optimal sizing determination is a key factor for pre-feasibility and feasibility analysis of hybrid system for any specific site. The capacity of battery, diesel generator (DG) and converter is determined with this novel approach ensuring a low cost reliable system with zero load rejection. Here, instead of taking maximum value of surplus or deficit energy or predefined rated components for obtaining size of battery, DG and converter, a random number between minimum and maximum values are considered as the criteria for selection. A detailed flow chart describing the approach and operational energy flow is presented. The system total net present cost (TNPC) and levelized unit electricity cost (LUEC) are obtained of the optimal configuration of hybrid system yielding system feasibility and approach adoptability.
本文提出了一种新的光伏-风力混合发电系统各组成部分的策略选择方法。最优尺寸的确定是进行混合动力系统预可行性和可行性分析的关键因素。采用该方法确定了电池、柴油发电机和变流器的容量,确保了系统零负荷、低成本、可靠。在这里,电池、DG和变换器的尺寸不是取剩余或亏能的最大值,也不是取预定义的额定分量的最大值,而是取最小值和最大值之间的随机数作为选择标准。给出了描述该方法和操作能量流的详细流程图。得到了混合系统最优配置下的系统总净当前成本(TNPC)和平准化单位电力成本(LUEC),给出了系统的可行性和方法的可采用性。
{"title":"A novel strategy for determination of optimal sizing of PV-wind hybrid system","authors":"B. Tudu, K. Mandal, N. Chakraborty","doi":"10.1109/CIEC.2016.7513767","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513767","url":null,"abstract":"A novel methodology for strategic selection of different components of PV-wind hybrid system is presented here. The optimal sizing determination is a key factor for pre-feasibility and feasibility analysis of hybrid system for any specific site. The capacity of battery, diesel generator (DG) and converter is determined with this novel approach ensuring a low cost reliable system with zero load rejection. Here, instead of taking maximum value of surplus or deficit energy or predefined rated components for obtaining size of battery, DG and converter, a random number between minimum and maximum values are considered as the criteria for selection. A detailed flow chart describing the approach and operational energy flow is presented. The system total net present cost (TNPC) and levelized unit electricity cost (LUEC) are obtained of the optimal configuration of hybrid system yielding system feasibility and approach adoptability.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115881845","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Transient analysis of mechanically switched capacitors with and without damping network connected to A.C grid 机械开关电容器与交流电网连接时有无阻尼网络的暂态分析
R. Bose, K. Samanta, K. Ghosh, R. Bandyopadhyay, S. Chatterjee
Mechanically switched capacitors (MSC) are very well known reactive power compensation devices which are extensively in use in power transmission systems. However, during switching of MSC in a high voltage grid, significant transients are found to appear across the capacitor bank bus as well as different elements of MSC which may lead to insulation degradation affecting the long term performance of the capacitor banks. An improved version of the MSC is MSCDN where a damping network is employed with the capacitor banks to damp out the transient oscillations. However, during switching of a MSCDN plant significant transients are observed across its different elements. Considering the afore-said fact, in this contribution, a comparative study of transient behavior of mechanically switched capacitors with and without damping network is presented during switching in a 400 kV A.C grid. Transient simulations are performed on an exemplary MSC and MSCDN model using PSCAD/EMTDC software. It has been observed that there is a significant reduction in transient overvoltage and inrush current in switching a MSCDN plant when compared to a mere MSC switching. Moreover, the percentage reduction in transient overvoltage and inrush current during switching a MSCDN plant is found to depend on the design of damping network which may be important to analyze the transient behavior during switching in a high voltage A.C grid.
机械开关电容器(MSC)是一种非常有名的无功补偿器件,在输电系统中得到了广泛的应用。然而,在高压电网中切换MSC时,发现在电容器组总线以及MSC的不同元件上出现了显着的瞬变,这可能导致影响电容器组长期性能的绝缘退化。MSC的改进版本是MSCDN,其中阻尼网络与电容器组一起使用,以抑制瞬态振荡。然而,在MSCDN设备的交换过程中,在其不同的元件之间观察到显著的瞬变。考虑到上述事实,在这篇论文中,对400 kV交流电网中有阻尼网络和没有阻尼网络的机械开关电容器在开关过程中的暂态行为进行了比较研究。利用PSCAD/EMTDC软件对示例性MSC和MSCDN模型进行了瞬态仿真。已经观察到,与单纯的MSC开关相比,在切换MSCDN工厂时,瞬态过电压和涌流显着减少。此外,在MSCDN装置的切换过程中,暂态过电压和涌流的降低百分比取决于阻尼网络的设计,这对于分析高压交流电网切换过程中的暂态行为可能是重要的。
{"title":"Transient analysis of mechanically switched capacitors with and without damping network connected to A.C grid","authors":"R. Bose, K. Samanta, K. Ghosh, R. Bandyopadhyay, S. Chatterjee","doi":"10.1109/CIEC.2016.7513789","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513789","url":null,"abstract":"Mechanically switched capacitors (MSC) are very well known reactive power compensation devices which are extensively in use in power transmission systems. However, during switching of MSC in a high voltage grid, significant transients are found to appear across the capacitor bank bus as well as different elements of MSC which may lead to insulation degradation affecting the long term performance of the capacitor banks. An improved version of the MSC is MSCDN where a damping network is employed with the capacitor banks to damp out the transient oscillations. However, during switching of a MSCDN plant significant transients are observed across its different elements. Considering the afore-said fact, in this contribution, a comparative study of transient behavior of mechanically switched capacitors with and without damping network is presented during switching in a 400 kV A.C grid. Transient simulations are performed on an exemplary MSC and MSCDN model using PSCAD/EMTDC software. It has been observed that there is a significant reduction in transient overvoltage and inrush current in switching a MSCDN plant when compared to a mere MSC switching. Moreover, the percentage reduction in transient overvoltage and inrush current during switching a MSCDN plant is found to depend on the design of damping network which may be important to analyze the transient behavior during switching in a high voltage A.C grid.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130662412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A study on wide-area controller design for inter-area oscillation damping 区域间振荡阻尼广域控制器设计研究
Abhilash Patel, S. Samal, Sandip Ghosh, B. Subudhi
In a modern power system, damping of an inter-area mode is crucial as it limits the power transfer capability. With the progress in Wide-Area Measurement System (WAMS), now dynamic data from wide geographical areas are available readily. The accuracy of such data motivates to be used as feedback for controllers, which can have better performance. The placement of such controllers and the signals to be considered as feedback with the redundancy, such that action will be effective is an interesting idea to deal. The paper deals with the issue of wide-area loop selection in a detailed manner. The selection considers not only being strongly controllable/observable but also the interaction and robustness issue. A static controller performance is compared with dynamic controllers (Lead-Lag compensator, PI Controller, Multi-Objective Controller). The controllers are synthesized so as to minimize the H∞ norm. The designed controllers are validated through a four machine case study.
在现代电力系统中,区域间模式的阻尼是至关重要的,因为它限制了电力传输的能力。随着广域测量系统(WAMS)的发展,现在可以随时获得广泛地理区域的动态数据。这些数据的准确性激励我们将其作为控制器的反馈,从而获得更好的性能。这样的控制器和信号的位置被认为是反馈的冗余,这样的行动将是有效的是一个有趣的想法来处理。本文详细地讨论了广域环路的选择问题。该选择不仅考虑了强可控/强可观察性,还考虑了交互和鲁棒性问题。比较了静态控制器与动态控制器(超前滞后补偿器、PI控制器、多目标控制器)的性能。对控制器进行综合,使H∞范数最小。通过四机实例研究验证了所设计的控制器的有效性。
{"title":"A study on wide-area controller design for inter-area oscillation damping","authors":"Abhilash Patel, S. Samal, Sandip Ghosh, B. Subudhi","doi":"10.1109/CIEC.2016.7513758","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513758","url":null,"abstract":"In a modern power system, damping of an inter-area mode is crucial as it limits the power transfer capability. With the progress in Wide-Area Measurement System (WAMS), now dynamic data from wide geographical areas are available readily. The accuracy of such data motivates to be used as feedback for controllers, which can have better performance. The placement of such controllers and the signals to be considered as feedback with the redundancy, such that action will be effective is an interesting idea to deal. The paper deals with the issue of wide-area loop selection in a detailed manner. The selection considers not only being strongly controllable/observable but also the interaction and robustness issue. A static controller performance is compared with dynamic controllers (Lead-Lag compensator, PI Controller, Multi-Objective Controller). The controllers are synthesized so as to minimize the H∞ norm. The designed controllers are validated through a four machine case study.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"35 10","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"113965428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A novel technique for optimal PMU placement with effects on dynamic state estimation 一种影响动态估计的PMU最优放置方法
R. Dubey
In this paper a new priority based elimination technique (PBET) has been presented to obtain minimum number of phasor measurement unit (PMU) in power system network for full system observability and based on optimal PMU location state estimation (SE) has been done. Power system network should completely observable hence it's required to have all bus data in real time. It is not neither necessary to have PMUs at each buses in network nor economical. The proposed method is based on simple algorithm without having any cost function. Four steps procedure has been discussed in detailed for IEEE-14, IEEE-24 and IEEE-30 bus system and results are compared with other techniques. State estimation has been discussed for IEEE-14 bus system and normalized errors are obtained with optimally placed PMU and other configuration of PMU. Results show that PBET is compatible with other techniques of PMU placement.
本文提出了一种新的基于优先级的消去技术(PBET),以获得电网中最优相量测量单元(PMU)的数量,实现了系统的完全可观测性,并基于最优PMU位置状态估计(SE)。电力系统网络应该是完全可观测的,因此要求所有母线的数据都是实时的。在网络的每条总线上都安装pmu既没有必要,也不经济。该方法基于简单的算法,不含任何代价函数。详细讨论了IEEE-14、IEEE-24和IEEE-30总线系统的四步程序,并与其他技术的结果进行了比较。讨论了IEEE-14总线系统的状态估计问题,并在PMU的最优位置和PMU的其他配置下得到归一化误差。结果表明,PBET与其他PMU放置技术是兼容的。
{"title":"A novel technique for optimal PMU placement with effects on dynamic state estimation","authors":"R. Dubey","doi":"10.1109/CIEC.2016.7513825","DOIUrl":"https://doi.org/10.1109/CIEC.2016.7513825","url":null,"abstract":"In this paper a new priority based elimination technique (PBET) has been presented to obtain minimum number of phasor measurement unit (PMU) in power system network for full system observability and based on optimal PMU location state estimation (SE) has been done. Power system network should completely observable hence it's required to have all bus data in real time. It is not neither necessary to have PMUs at each buses in network nor economical. The proposed method is based on simple algorithm without having any cost function. Four steps procedure has been discussed in detailed for IEEE-14, IEEE-24 and IEEE-30 bus system and results are compared with other techniques. State estimation has been discussed for IEEE-14 bus system and normalized errors are obtained with optimally placed PMU and other configuration of PMU. Results show that PBET is compatible with other techniques of PMU placement.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115074199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1