首页 > 最新文献

European Journal of Prosthodontics and Restorative Dentistry最新文献

英文 中文
Impact of Compensating Curves on Mastication of Complete Denture Wearers: A Randomised Triple-Blind Clinical Trial. 补偿曲线对全口义齿佩戴者咀嚼的影响:一项随机三盲临床试验。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2617Janz11
J M Janz, Y N Reis, V J de Oliveira, D E Carneiro, A F Cartagena, A Sánchez-Ayala

Introduction: The application of occlusal concepts in prosthodontics is still under debate.This study assessed the impact of compensating curves on the comminution of complete denture wearers.

Methods: Seven edentulous subjects, aged 64.6 ± 2.0 years, were rehabilitated with new muco-supported complete dentures and tested in two occlusal plane settings: with and without compensating curves. A randomised triple-blind clinical trial was conducted, considering one-week and one-month as adaptation periods for dentures. After each trial, the subjects were crossed over to their respective groups. One-week was also chosen as the washout period, and after that, the subjects were re-examined. The masticatory performance and swallowing threshold were determined while chewing Optocal test food. The multiple sieve method was used for fractionation and granulometry.

Results: During the masticatory performance and swallowing threshold estimates, no differences were found between the median particle sizes obtained with the both occlusal plane conditions (P ⟩ 0.05). However, the swallowing threshold improved after one month, resulting in smaller particle sizes. Moreover, the chewing rates for the both test foods were also increased (P ⟨ 0.05).

Conclusions: These findings suggest that the compensating curves did not have an impact on the masticatory function of subjects wearing complete dentures.

咬合概念在口腔修复学中的应用仍存在争议。本研究评估了补偿曲线对全口义齿佩戴者粉碎的影响。方法:7例无牙缺牙患者,年龄64.6±2.0岁,采用新型黏液支持全口义齿进行修复,并在有补偿曲线和无补偿曲线两种咬合平面设置下进行测试。采用随机三盲临床试验,假牙适应期分别为1周和1个月。每次试验结束后,受试者被划分到各自的小组。同时选择1周作为洗脱期,洗脱期结束后再对受试者进行检查。测定大鼠咀嚼光测食物时的咀嚼性能和吞咽阈值。采用多筛法进行分馏和粒度测定。结果:在咀嚼性能和吞咽阈值估计期间,在两种咬合平面条件下获得的中位粒径之间没有发现差异(P⟩0.05)。然而,吞咽阈值在一个月后有所改善,导致颗粒尺寸变小。两种试验食品的咀嚼率均提高(P⟨0.05)。结论:补偿曲线对全口义齿的咀嚼功能无明显影响。
{"title":"Impact of Compensating Curves on Mastication of Complete Denture Wearers: A Randomised Triple-Blind Clinical Trial.","authors":"J M Janz, Y N Reis, V J de Oliveira, D E Carneiro, A F Cartagena, A Sánchez-Ayala","doi":"10.1922/EJPRD_2617Janz11","DOIUrl":"10.1922/EJPRD_2617Janz11","url":null,"abstract":"<p><strong>Introduction: </strong>The application of occlusal concepts in prosthodontics is still under debate.This study assessed the impact of compensating curves on the comminution of complete denture wearers.</p><p><strong>Methods: </strong>Seven edentulous subjects, aged 64.6 ± 2.0 years, were rehabilitated with new muco-supported complete dentures and tested in two occlusal plane settings: with and without compensating curves. A randomised triple-blind clinical trial was conducted, considering one-week and one-month as adaptation periods for dentures. After each trial, the subjects were crossed over to their respective groups. One-week was also chosen as the washout period, and after that, the subjects were re-examined. The masticatory performance and swallowing threshold were determined while chewing Optocal test food. The multiple sieve method was used for fractionation and granulometry.</p><p><strong>Results: </strong>During the masticatory performance and swallowing threshold estimates, no differences were found between the median particle sizes obtained with the both occlusal plane conditions (P ⟩ 0.05). However, the swallowing threshold improved after one month, resulting in smaller particle sizes. Moreover, the chewing rates for the both test foods were also increased (P ⟨ 0.05).</p><p><strong>Conclusions: </strong>These findings suggest that the compensating curves did not have an impact on the masticatory function of subjects wearing complete dentures.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"142-152"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138292039","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Survival and Success Rates of Endodontically Treated Teeth Restored with Full Veneer Crowns or Full Cuspal Coverage onlays: A Systematic Review. 用全贴面冠或全牙冠覆盖嵌体修复根管治疗牙齿的存活率和成功率:系统回顾。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2547Lane11
J Lane, A Sadeghzadeh-Araghi, G Jackson, S Bonsor

Introduction: The aim of this paper is to compare the survival and success rates of endodontically treated posterior teeth restored with full veneer crowns or full cuspal coverage onlays in vivo.

Methods: A literature search using PubMed, Medline and Embase via Ovid, and The Cochrane Library retrieved English and non-English language articles from 1946 to April 2022. Electronic searches were supplemented with the use of forward citation chaining via Google Scholar.

Results: A total of eleven studies met all predetermined search criteria. Data were extracted and tabulated. Survival rates for onlays ranged from 95% to 100% at two years and 90.7% to 100% at three years with success rates ranging from 86.6% - 96.6% at two years and 86.6% to 96% at three years. Survival results for full veneer crowns were reported at 87.8% at over two years, 95.1% at three years, and 84% - 97.73% at five to ten years. Success rates have been reported at 91.11% - 92.64% at five years and 60% at six years.

Conclusions: The data suggest that the use of onlays instead of full veneer crowns in the restoration of endodontically treated posterior teeth is favourable in the short to midterm.

引言本文旨在比较采用全贴面冠或全尖面覆盖嵌体修复的根管治疗后牙的存活率和成功率:使用 PubMed、Medline 和 Embase(通过 Ovid)以及 Cochrane 图书馆进行文献检索,检索了 1946 年至 2022 年 4 月期间的英语和非英语文章。此外,还通过谷歌学术(Google Scholar)使用前向引文链对电子检索进行了补充:共有 11 项研究符合所有预定的检索标准。数据已提取并制成表格。镶牙两年的存活率在 95% 到 100% 之间,三年的存活率在 90.7% 到 100% 之间,两年的成功率在 86.6% 到 96.6% 之间,三年的成功率在 86.6% 到 96% 之间。据报道,全贴面牙冠两年以上的存活率为 87.8%,三年的存活率为 95.1%,五到十年的存活率为 84% - 97.73%。五年的成功率为 91.11% - 92.64%,六年的成功率为 60%:这些数据表明,在中短期内,使用嵌体代替全瓷冠修复经牙髓治疗的后牙是有利的。
{"title":"Survival and Success Rates of Endodontically Treated Teeth Restored with Full Veneer Crowns or Full Cuspal Coverage onlays: A Systematic Review.","authors":"J Lane, A Sadeghzadeh-Araghi, G Jackson, S Bonsor","doi":"10.1922/EJPRD_2547Lane11","DOIUrl":"10.1922/EJPRD_2547Lane11","url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this paper is to compare the survival and success rates of endodontically treated posterior teeth restored with full veneer crowns or full cuspal coverage onlays in vivo.</p><p><strong>Methods: </strong>A literature search using PubMed, Medline and Embase via Ovid, and The Cochrane Library retrieved English and non-English language articles from 1946 to April 2022. Electronic searches were supplemented with the use of forward citation chaining via Google Scholar.</p><p><strong>Results: </strong>A total of eleven studies met all predetermined search criteria. Data were extracted and tabulated. Survival rates for onlays ranged from 95% to 100% at two years and 90.7% to 100% at three years with success rates ranging from 86.6% - 96.6% at two years and 86.6% to 96% at three years. Survival results for full veneer crowns were reported at 87.8% at over two years, 95.1% at three years, and 84% - 97.73% at five to ten years. Success rates have been reported at 91.11% - 92.64% at five years and 60% at six years.</p><p><strong>Conclusions: </strong>The data suggest that the use of onlays instead of full veneer crowns in the restoration of endodontically treated posterior teeth is favourable in the short to midterm.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"45-55"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10007808","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Zirconia Implants Produced by Additive Manufacturing - A Scoping Review. 用增材制造技术生产氧化锆假体--范围审查。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2513Kreve11
S Kreve, I Ferreira, A C Dos Reis

Introduction: Additive manufacturing is a tool with potential use in medicine and dentistry. The manufacture of metals and composites is already advanced, however, concerns about titanium hypersensitivity, tissue staining, and corrosion caused by gradual material degradation encourage research into more biocompatible alternatives.

Objective: This systematic scoping review aimed to gather studies that evaluated zirconia implants produced by additive manufacturing to describe the current stage of the printing technique and the final product.

Methods: Searches in Embase, PubMed, SCOPUS, Web of Science, and Google Scholar databases were enriched with manual searches between February and March 2021 and updated in June 2022 using keywords: zirconium implants, zirconium oxide, additive manufacturing, rapid prototyping, 3D printing, selective laser melting, and electron beam melting. The criteria included studies that evaluated or described zirconia implants obtained by 3D printing, with a direct relationship to dentistry or orthopedics.

Results: The database search resulted in 671 articles. Eight articles were selected for full reading and remained in this systematic review.

Conclusion: The printing technique for zirconia implants is promising. However, further studies are required before implants produced by the printing technique can be tested clinically. The literature with results regarding the impression product is still limited.

简介快速成型技术是一种可用于医学和牙科的工具。金属和复合材料的制造技术已经非常先进,然而,由于人们对钛的过敏性、组织染色以及材料逐渐降解造成的腐蚀等问题的担忧,促使人们研究生物相容性更好的替代品:本系统性范围界定综述旨在收集通过增材制造技术生产氧化锆植入物的评估研究,以描述现阶段的打印技术和最终产品:在 2021 年 2 月至 3 月期间,通过人工检索对 Embase、PubMed、SCOPUS、Web of Science 和 Google Scholar 数据库进行了搜索,并于 2022 年 6 月进行了更新,使用的关键词包括:锆植入物、氧化锆、快速成型制造、快速原型、3D 打印、选择性激光熔化和电子束熔化。标准包括评估或描述通过三维打印技术获得的氧化锆植入物的研究,这些研究与牙科或整形外科有直接关系:结果:数据库搜索结果为 671 篇文章。结果:通过数据库搜索,共获得 671 篇文章,其中 8 篇文章被选中进行全文阅读,并保留在本系统综述中:结论:氧化锆种植体的打印技术前景广阔。结论:氧化锆种植体的打印技术前景广阔,但在对打印技术生产的种植体进行临床测试之前,还需要进一步的研究。有关印模产品结果的文献仍然有限。
{"title":"Zirconia Implants Produced by Additive Manufacturing - A Scoping Review.","authors":"S Kreve, I Ferreira, A C Dos Reis","doi":"10.1922/EJPRD_2513Kreve11","DOIUrl":"10.1922/EJPRD_2513Kreve11","url":null,"abstract":"<p><strong>Introduction: </strong>Additive manufacturing is a tool with potential use in medicine and dentistry. The manufacture of metals and composites is already advanced, however, concerns about titanium hypersensitivity, tissue staining, and corrosion caused by gradual material degradation encourage research into more biocompatible alternatives.</p><p><strong>Objective: </strong>This systematic scoping review aimed to gather studies that evaluated zirconia implants produced by additive manufacturing to describe the current stage of the printing technique and the final product.</p><p><strong>Methods: </strong>Searches in Embase, PubMed, SCOPUS, Web of Science, and Google Scholar databases were enriched with manual searches between February and March 2021 and updated in June 2022 using keywords: zirconium implants, zirconium oxide, additive manufacturing, rapid prototyping, 3D printing, selective laser melting, and electron beam melting. The criteria included studies that evaluated or described zirconia implants obtained by 3D printing, with a direct relationship to dentistry or orthopedics.</p><p><strong>Results: </strong>The database search resulted in 671 articles. Eight articles were selected for full reading and remained in this systematic review.</p><p><strong>Conclusion: </strong>The printing technique for zirconia implants is promising. However, further studies are required before implants produced by the printing technique can be tested clinically. The literature with results regarding the impression product is still limited.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"9-19"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10287136","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Patient Satisfaction and Accuracy of Partial Denture Frameworks Fabricated using Conventional and Digital Techniques. 使用传统和数字技术制作的部分义齿框架的患者满意度和准确性。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2554Muehlemann10
E Muehlemann, N Al-Haj Husain, M Özcan

This case report compares a conventional and a digital workflow for manufacturing metal frameworks for maxillary and mandibular removable partial dentures (RPDs). Two sets of maxillary and mandible RPDs were produced. The metal framework of one set of RPDs was produced conventionally using the lost wax casting technique. Intraoralscanning and computer-aided designing (CAD) were used to fabricate the metal frameworks of the other set of RPDs using direct metal laser sintering (DMLS) technology. The accuracy of fit of the two sets of RPDs was evaluated after 3 months using replica models. Patient satisfaction was assessed. Two years later, the fit accuracy of the DMLS prosthesis and patient satisfaction were re-evaluated. The accuracy of fit in the maxillary RPD with the DLMS manufactured metal framework showed better results in all areas except areas of rests (457 vs. 421 μm) and the major connector (850 vs. 512 μm). The mandibular RPD with DLMS manufactured metal framework showed only in the areas of the reciprocal arm and major connector better fit accuracy compared to the conventional RPD. The patient satisfaction with the DLMS manufactured RPDs was rated equally to the conventional one. The use of digital technologies in manufacturing RPDs seems promising regarding accuracy and patient satisfaction.

本病例报告比较了制造上颌和下颌可摘局部义齿(RPD)金属框架的传统和数字工作流程。制作了两套上颌和下颌RPD。一套RPD的金属框架采用传统的失蜡铸造技术生产。使用直接金属激光烧结(DMLS)技术,使用口腔内扫描和计算机辅助设计(CAD)来制造另一组RPD的金属框架。3个月后,使用复制模型评估两组RPD的拟合准确性。评估患者满意度。两年后,对DMLS假体的拟合精度和患者满意度进行了重新评估。DLMS制造的金属框架在上颌RPD中的拟合精度在除休息区(457对421μm)和主连接区(850对512μm)之外的所有区域都显示出更好的结果。与传统RPD相比,DLMS制造的金属框架的下颌RPD仅在倒臂和主连接器的区域显示出更好的装配精度。患者对DLMS制造的RPD的满意度与传统RPD的评分相同。数字技术在制造RPD中的应用在准确性和患者满意度方面似乎很有希望。
{"title":"Patient Satisfaction and Accuracy of Partial Denture Frameworks Fabricated using Conventional and Digital Techniques.","authors":"E Muehlemann, N Al-Haj Husain, M Özcan","doi":"10.1922/EJPRD_2554Muehlemann10","DOIUrl":"10.1922/EJPRD_2554Muehlemann10","url":null,"abstract":"<p><p>This case report compares a conventional and a digital workflow for manufacturing metal frameworks for maxillary and mandibular removable partial dentures (RPDs). Two sets of maxillary and mandible RPDs were produced. The metal framework of one set of RPDs was produced conventionally using the lost wax casting technique. Intraoralscanning and computer-aided designing (CAD) were used to fabricate the metal frameworks of the other set of RPDs using direct metal laser sintering (DMLS) technology. The accuracy of fit of the two sets of RPDs was evaluated after 3 months using replica models. Patient satisfaction was assessed. Two years later, the fit accuracy of the DMLS prosthesis and patient satisfaction were re-evaluated. The accuracy of fit in the maxillary RPD with the DLMS manufactured metal framework showed better results in all areas except areas of rests (457 vs. 421 μm) and the major connector (850 vs. 512 μm). The mandibular RPD with DLMS manufactured metal framework showed only in the areas of the reciprocal arm and major connector better fit accuracy compared to the conventional RPD. The patient satisfaction with the DLMS manufactured RPDs was rated equally to the conventional one. The use of digital technologies in manufacturing RPDs seems promising regarding accuracy and patient satisfaction.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"65-74"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41183844","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Effect of Different Decontamination Methods on the Micro-Tensile Bond Strength of CAD/CAM Resin-Based Blocks to Resin Cement. 不同去污方法对CAD/CAM树脂基砌块与树脂水泥微拉伸粘结强度的影响。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2588Soler-Tornero13
C Soler-Tornero, M M Mutluay

Introduction: This study evaluates the impact of decontamination methods on Microtensile bond strength (μTBS) between resin cement and resin blocks.

Methods: Twenty CAD/CAM resin blocks from two manufacturers were wet-polished, sandblasted, and ultrasonically cleaned. After blood and saliva contamination, blocks were divided into subgroups: control, water rinsing, acid etching, alkaline cleaning paste, or 10-MDP containing cleaner. Resin-based cement was then applied. After 24 hours, the blocks were sectioned to obtain bars for testing. Half of the specimens were tested immediately for μTBS, and the other half underwent artificial aging. The surfaces of the blocks were inspected with a scanning electron microscope (SEM). Three-way ANOVA was performed for μTBS values (α=0.05).

Results: In one of the substrates, the positive control subgroup obtained the highest value (56,01 MPa, SD:6,96) followed by 10-MDP cleaner and universal cleaning paste, when immediately tested, with significant differences respect to the water rinsing (p⟨0.041) and acid etching (p⟨0.048) groups. After thermocycling, higher values were found in the 10-MDP cleaner (47,57 MPa, SD:8,15), but differences were not significant. In the other substrate group, the 10-MDP cleaner subgroup showed highest bond strengths (64,46 MPa SD: 10,92) at the initial test. After thermocycling, 10-MDP cleaner (58,66 MPa, SD: 9,93) gave the highest μTBS value. Significant differences between water rinsing group and the rest of subgroups (p⟨0.001), and between 10-MDP cleaner and the positive control group (p⟨0.006) were observed.

Conclusion: Cleaning after contamination improves bonding. 10-MDP containing cleaner can help to restore initial μTBS value and maintain it in the long-term.

摘要:本研究评价了不同净化方法对树脂水泥与树脂块间微拉伸粘结强度(μTBS)的影响。方法:对两家厂家生产的20块CAD/CAM树脂块进行湿抛光、喷砂和超声清洗。血液和唾液污染后,将块分为对照组、水冲洗组、酸蚀刻组、碱性清洁膏组和含10-MDP清洁剂组。然后应用树脂基水泥。24小时后,对块体进行切片,获得棒材进行检测。其中一半立即进行μTBS检测,另一半进行人工老化。用扫描电子显微镜(SEM)对砌块表面进行了观察。对μTBS值进行三向方差分析(α=0.05)。结果:在其中一种底物中,阳性对照亚组获得的值最高(56,01 MPa, SD:6,96),其次是10-MDP清洁剂和通用清洁膏,立即测试时,水冲洗组(p⟨0.041)和酸蚀刻组(p⟨0.048)差异显著。经过热循环后,10-MDP清洗剂的值较高(47、57 MPa, SD:8、15),但差异不显著。在其他基材组中,10- mdp清洁亚组在初始测试时显示出最高的结合强度(64、46 MPa SD: 10、92)。热循环后,10-MDP清洗剂(58、66 MPa, SD: 9、93)的μTBS值最高。水冲洗组与其他亚组之间存在显著差异(p⟨0.001),10-MDP清洁剂与阳性对照组之间存在显著差异(p⟨0.006)。结论:污染后清洗可改善粘接。含有10-MDP的清洗剂有助于恢复初始μTBS值并长期维持。
{"title":"The Effect of Different Decontamination Methods on the Micro-Tensile Bond Strength of CAD/CAM Resin-Based Blocks to Resin Cement.","authors":"C Soler-Tornero, M M Mutluay","doi":"10.1922/EJPRD_2588Soler-Tornero13","DOIUrl":"10.1922/EJPRD_2588Soler-Tornero13","url":null,"abstract":"<p><strong>Introduction: </strong>This study evaluates the impact of decontamination methods on Microtensile bond strength (μTBS) between resin cement and resin blocks.</p><p><strong>Methods: </strong>Twenty CAD/CAM resin blocks from two manufacturers were wet-polished, sandblasted, and ultrasonically cleaned. After blood and saliva contamination, blocks were divided into subgroups: control, water rinsing, acid etching, alkaline cleaning paste, or 10-MDP containing cleaner. Resin-based cement was then applied. After 24 hours, the blocks were sectioned to obtain bars for testing. Half of the specimens were tested immediately for μTBS, and the other half underwent artificial aging. The surfaces of the blocks were inspected with a scanning electron microscope (SEM). Three-way ANOVA was performed for μTBS values (α=0.05).</p><p><strong>Results: </strong>In one of the substrates, the positive control subgroup obtained the highest value (56,01 MPa, SD:6,96) followed by 10-MDP cleaner and universal cleaning paste, when immediately tested, with significant differences respect to the water rinsing (p⟨0.041) and acid etching (p⟨0.048) groups. After thermocycling, higher values were found in the 10-MDP cleaner (47,57 MPa, SD:8,15), but differences were not significant. In the other substrate group, the 10-MDP cleaner subgroup showed highest bond strengths (64,46 MPa SD: 10,92) at the initial test. After thermocycling, 10-MDP cleaner (58,66 MPa, SD: 9,93) gave the highest μTBS value. Significant differences between water rinsing group and the rest of subgroups (p⟨0.001), and between 10-MDP cleaner and the positive control group (p⟨0.006) were observed.</p><p><strong>Conclusion: </strong>Cleaning after contamination improves bonding. 10-MDP containing cleaner can help to restore initial μTBS value and maintain it in the long-term.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"120-132"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138292041","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Surface Wear and Retention Force of Zirconia and PEKK Implant-retained Crowns. 氧化锆和 PEKK 种植体固位冠的表面磨损和固位力。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2524Emera08
R M K Emera, O Askar

Purpose: The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures.

Materials and methods: Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6).

Results: The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use.

Conclusion: Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.

目的:本研究旨在评估氧化锆主冠和聚醚酮(PEKK)次冠制成的伸缩式附着体的表面磨损和固位力,用于双种植体固位的下颌全覆盖义齿:本研究选择了 10 名 55-60 岁的健康全口无牙患者。每位患者都在下颌犬齿区植入了两颗种植体。所有患者的上颌传统全口义齿与种植体固位的下颌覆盖义齿均已制作完成。为固位覆盖义齿,制作了氧化锆-PEKK伸缩式连接体,其中主连接体由氧化锆制成,副连接体由PEKK制成。对安装覆盖义齿时(T0)和使用覆盖义齿 6 个月后(T6)的固位力和表面磨损情况进行了评估:结果显示,在 T0 和 T6 阶段,氧化锆义齿的磨损程度低于 PEKK 义齿。然而,在覆盖义齿使用 6 个月后,两种材料的磨损都不明显。结论:在本研究的限制条件下,PEKK 在耐磨性和令人满意的固位力方面,可以被认为是与氧化锆基底冠结合使用的伸缩式基底冠的理想替代材料。
{"title":"Surface Wear and Retention Force of Zirconia and PEKK Implant-retained Crowns.","authors":"R M K Emera, O Askar","doi":"10.1922/EJPRD_2524Emera08","DOIUrl":"10.1922/EJPRD_2524Emera08","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures.</p><p><strong>Materials and methods: </strong>Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6).</p><p><strong>Results: </strong>The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use.</p><p><strong>Conclusion: </strong>Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"20-27"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10309753","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Co-Influence of Restoration Bonding and Inlay Cavity Design on Fracture Load of Restored Tooth. 修复粘接和嵌体牙洞设计对修复牙断裂负荷的共同影响
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2510Yli-Urpo08
T Yli-Urpo, L Lassila, P Vallittu, T Närhi

Introduction: The aim of this study was to investigate the co-influence of indirect mesio- occlusal-distal (MOD) cavity geometry and inlay restoration bonding on quasi-static fracture load of the restored tooth.

Methods: Forty-eight intact human molar teeth were selected and prepared for standardized edge-shaped or round-shaped MOD cavities. The resin composite (Cerasmart, GC) inlays were bonded with the state-of-the-art inlay bonding protocol or with intentionally deteriorated bonding using n-hexane-wax solution for preconditioning. Restored teeth were loaded along the long axis of the tooth. Ultimate fracture load was recorded, and the type of fracture was visually determined and classified. Statistical analysis of load values was performed by Kruskal-Wallis test.

Results: Round-shaped cavity design with bonded restoration presented the highest fracture load (1658N). Bonding had significant influence on the fracture load of roundshaped cavity design (p=0.0003), whereas cavity design had no influence when the bonding was deteriorated (p=0.8075). In the case of deteriorated bonding, either the inlay or tooth fractured separately whereas in the bonded inlays fractures were commonly found both in the tooth and inlay.

Conclusions: According to this study, bonded inlay restoration increased fracture resistance, while cavity design had no statistical difference on fracture resistance of the restored tooth.

导言:本研究旨在探讨间接中-咬合-远端(MOD)牙洞的几何形状和嵌体修复粘接对修复牙准静态折断载荷的共同影响:方法:选择 48 颗完整的人类臼齿,制备标准的边缘型或圆形 MOD 牙洞。采用最先进的嵌体粘接方案或使用正己烷-蜡溶液进行预处理的故意劣化粘接方案粘接树脂复合材料(Cerasmart,GC)嵌体。修复后的牙齿沿牙齿长轴加载。记录终极断裂荷载,目测断裂类型并进行分类。载荷值的统计分析采用 Kruskal-Wallis 检验:结果:带有粘接修复体的圆形牙洞设计的断裂载荷最高(1658N)。粘接对圆形牙洞设计的断裂载荷有明显影响(p=0.0003),而粘接变差时,牙洞设计没有影响(p=0.8075)。在粘结力变差的情况下,嵌体或牙齿分别发生断裂,而在粘结嵌体中,牙齿和嵌体都普遍发生断裂:根据这项研究,粘结嵌体修复增加了抗折性,而牙洞设计对修复后牙齿的抗折性没有统计学差异。
{"title":"Co-Influence of Restoration Bonding and Inlay Cavity Design on Fracture Load of Restored Tooth.","authors":"T Yli-Urpo, L Lassila, P Vallittu, T Närhi","doi":"10.1922/EJPRD_2510Yli-Urpo08","DOIUrl":"10.1922/EJPRD_2510Yli-Urpo08","url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this study was to investigate the co-influence of indirect mesio- occlusal-distal (MOD) cavity geometry and inlay restoration bonding on quasi-static fracture load of the restored tooth.</p><p><strong>Methods: </strong>Forty-eight intact human molar teeth were selected and prepared for standardized edge-shaped or round-shaped MOD cavities. The resin composite (Cerasmart, GC) inlays were bonded with the state-of-the-art inlay bonding protocol or with intentionally deteriorated bonding using n-hexane-wax solution for preconditioning. Restored teeth were loaded along the long axis of the tooth. Ultimate fracture load was recorded, and the type of fracture was visually determined and classified. Statistical analysis of load values was performed by Kruskal-Wallis test.</p><p><strong>Results: </strong>Round-shaped cavity design with bonded restoration presented the highest fracture load (1658N). Bonding had significant influence on the fracture load of roundshaped cavity design (p=0.0003), whereas cavity design had no influence when the bonding was deteriorated (p=0.8075). In the case of deteriorated bonding, either the inlay or tooth fractured separately whereas in the bonded inlays fractures were commonly found both in the tooth and inlay.</p><p><strong>Conclusions: </strong>According to this study, bonded inlay restoration increased fracture resistance, while cavity design had no statistical difference on fracture resistance of the restored tooth.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"1-8"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10309756","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Micromorphology of Root Canal Walls After Laser Activated Irrigation. 激光激活灌洗后根管管壁的微观形态。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2600AntonyOtero11
C I Anton Y Otero, L Marger, A Feilzer, I Krejci, M Abdelaziz

This study aims to investigate the effects of laser-activated irrigation on root canal dentin using different laser wavelengths. Sixty-six roots were prepared and split longitudinally. First, lasers with different power settings were tested on 34 samples, pre-etched with phosphoric acid, or remaining with a smear-layer to determine the test parameters. Selected parameters were then applied on thirty roots (9 groups) covered with smear layer: 1. Smear-layer removed; 2. Smear-layer untouched; 3. Conventional needle irrigation with NaOCl and EDTA; 4. ER:YAG laser; 5. 9.3 μm CO₂ laser; 6-9. Diode lasers. All lasers were applied in ultra-pure water as an irrigant. Root halves were examined by scanning electron microscope to analyze the intracanal dentin micromorphology on 9 consequent photos per specimen @ a magnification of 1000X. The results showed that conventional needle irrigation was effective in removing the smear-layer from coronal and middle root parts, while laser-activated irrigation had two main mechanisms: cleaning and opening of the dentinal tubules by removing the smear layer (Er:YAG laser) and melting of dentin (CO₂ and diode lasers) in all root parts. The study concluded that laseractivated irrigation with different wavelengths impacted the smear layer and root canal dentin differently through pure physical/mechanical effects.

本研究旨在探讨不同波长激光对根管内牙本质的影响。制备66根,纵裂。首先,在34个样品上测试了不同功率设置的激光器,用磷酸预蚀刻,或保留涂抹层以确定测试参数。然后将选定的参数应用于30根(9组)上,覆盖涂抹层:1。Smear-layer切除;2. Smear-layer不变;3.NaOCl联合EDTA常规针刺冲洗;4. 呃:掺钕钇铝石榴石激光器;5. 9.3 μm CO₂激光器;6 - 9。二极管激光器。所有激光都应用在超纯水中作为灌溉剂。通过扫描电子显微镜检查根半,分析每个标本在1000倍放大下的9张后续照片上的牙本质微观形态。结果表明,常规针刺冲洗法能有效去除冠状和中根部位的涂片层,而激光激活冲洗法主要有两种机制:通过去除涂片层(Er:YAG激光)和熔化牙本质(CO₂和二极管激光)来清洁和打开牙本质小管。结果表明,不同波长激光激活灌洗对牙本质和牙垢层的影响是不同的。
{"title":"Micromorphology of Root Canal Walls After Laser Activated Irrigation.","authors":"C I Anton Y Otero, L Marger, A Feilzer, I Krejci, M Abdelaziz","doi":"10.1922/EJPRD_2600AntonyOtero11","DOIUrl":"10.1922/EJPRD_2600AntonyOtero11","url":null,"abstract":"<p><p>This study aims to investigate the effects of laser-activated irrigation on root canal dentin using different laser wavelengths. Sixty-six roots were prepared and split longitudinally. First, lasers with different power settings were tested on 34 samples, pre-etched with phosphoric acid, or remaining with a smear-layer to determine the test parameters. Selected parameters were then applied on thirty roots (9 groups) covered with smear layer: 1. Smear-layer removed; 2. Smear-layer untouched; 3. Conventional needle irrigation with NaOCl and EDTA; 4. ER:YAG laser; 5. 9.3 μm CO₂ laser; 6-9. Diode lasers. All lasers were applied in ultra-pure water as an irrigant. Root halves were examined by scanning electron microscope to analyze the intracanal dentin micromorphology on 9 consequent photos per specimen @ a magnification of 1000X. The results showed that conventional needle irrigation was effective in removing the smear-layer from coronal and middle root parts, while laser-activated irrigation had two main mechanisms: cleaning and opening of the dentinal tubules by removing the smear layer (Er:YAG laser) and melting of dentin (CO₂ and diode lasers) in all root parts. The study concluded that laseractivated irrigation with different wavelengths impacted the smear layer and root canal dentin differently through pure physical/mechanical effects.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"109-119"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138292040","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Microtensile Bond Strength of Self-Etch Adhesives on Dentin Treated with Chlorhexidine. 用洗必泰处理过的牙本质上的自蚀刻粘合剂的显微拉伸粘合强度。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2590Furtado09
C O D A Furtado, K Baroudi, M Amaral, T N Amorim, K L Devito, M F de Goes, L A Salvio

Aim: To evaluate the microtensile bond strength of self-etching adhesive systems in dentin treated with 2% chlorhexidine digluconate (CHX).

Materials and methods: The occlusal surfaces of 20 human molars were removed and divided into eight groups: 1A, Clearfil SE adhesive (SE) with self-etching technique (TS); 1B, SE with TS and previous application of CHX; 2A, Scotchbond Universal (SBU) adhesive with TS; 2B, SBU adhesive with TS and previous application of CHX; 1C, SE with total-etching technique (TT); 1D, SE with TT and previous application of CHX; 2C, SBU with TT; 2D SBU with TT and previous application of CHX. Composite resin (5mm) was applied on the hybridized surface. Samples were subjected to microtensile test and evaluated on Scanning Electron Microscope (SEM) and with energy-dispersive X-ray (EDX).

Results: Low values of bond strength were observed in groups 1A (39,77±11,56) and 2A (40,84±12,49) comparing with 1B (22,86±5,18) and 2B (27,02±5,58). TS group presented adhesive type remover fracture while TT groups presented cohesive at the top of hybrid layer. EDX revealed the presence of CHX crystals for TS, which was not found in the TT.

Conclusion: The previous application of chlorhexidine on dentin decreased the bond strength of adhesive systems on self-etching technique.

目的:评估自酸洗粘接剂系统在经2%洗必泰二氯葡萄糖酸盐(CHX)处理的牙本质中的微拉伸粘接强度:取下 20 颗人类臼齿的咬合面,将其分为八组:1A 组,Clearfil SE 粘接剂(SE),自酸蚀技术(TS);1B 组,SE,TS,预先涂抹 CHX;2A 组,Scotchbond Universal(SBU)粘接剂,TS;2B 组,SBU 粘接剂,TS,预先涂抹 CHX;1C 组,SE,全酸蚀技术(TT);1D 组,SE,TT,预先涂抹 CHX;2C 组,SBU,TT;2D 组,SBU,TT,预先涂抹 CHX。在杂化表面涂上复合树脂(5 毫米)。对样品进行微拉伸测试,并用扫描电子显微镜(SEM)和能量色散 X 射线(EDX)进行评估:与 1B 组(22,86±5,18)和 2B 组(27,02±5,58)相比,1A 组(39,77±11,56)和 2A 组(40,84±12,49)的粘接强度值较低。TS 组呈现出粘合剂型剥离断裂,而 TT 组则在混合层顶部呈现出粘合剂型剥离断裂。EDX 显示 TS 组存在 CHX 晶体,而 TT 组则没有:结论:在牙本质上使用洗必泰会降低自酸蚀技术粘接剂系统的粘接强度。
{"title":"Microtensile Bond Strength of Self-Etch Adhesives on Dentin Treated with Chlorhexidine.","authors":"C O D A Furtado, K Baroudi, M Amaral, T N Amorim, K L Devito, M F de Goes, L A Salvio","doi":"10.1922/EJPRD_2590Furtado09","DOIUrl":"10.1922/EJPRD_2590Furtado09","url":null,"abstract":"<p><strong>Aim: </strong>To evaluate the microtensile bond strength of self-etching adhesive systems in dentin treated with 2% chlorhexidine digluconate (CHX).</p><p><strong>Materials and methods: </strong>The occlusal surfaces of 20 human molars were removed and divided into eight groups: 1A, Clearfil SE adhesive (SE) with self-etching technique (TS); 1B, SE with TS and previous application of CHX; 2A, Scotchbond Universal (SBU) adhesive with TS; 2B, SBU adhesive with TS and previous application of CHX; 1C, SE with total-etching technique (TT); 1D, SE with TT and previous application of CHX; 2C, SBU with TT; 2D SBU with TT and previous application of CHX. Composite resin (5mm) was applied on the hybridized surface. Samples were subjected to microtensile test and evaluated on Scanning Electron Microscope (SEM) and with energy-dispersive X-ray (EDX).</p><p><strong>Results: </strong>Low values of bond strength were observed in groups 1A (39,77±11,56) and 2A (40,84±12,49) comparing with 1B (22,86±5,18) and 2B (27,02±5,58). TS group presented adhesive type remover fracture while TT groups presented cohesive at the top of hybrid layer. EDX revealed the presence of CHX crystals for TS, which was not found in the TT.</p><p><strong>Conclusion: </strong>The previous application of chlorhexidine on dentin decreased the bond strength of adhesive systems on self-etching technique.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"133-141"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138811844","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of the Use of Irrigation Solution Inhibitors in Improving Dentine Adhesion: A Systematic Review and Meta-Analysis. 使用冲洗液抑制剂对改善牙本质附着力的影响:系统回顾与元分析》。
IF 1.3 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2024-02-29 DOI: 10.1922/EJPRD_2526Pierre17
F Z Pierre, L C L Gomes, G B Minhoto, M C Valera, R M de Melo, E Bresciani

Introduction: This systematic review examined the effect of neutralizing agents on bond strength after irrigation with sodium hypochlorite and their existing protocols in literature.

Methods: This present study adhered to the PRISMA guidelines and was registered at PROSPERO. Five electronic databases were searched (sept-2020/jan-2021) in English, Spanish, and Portuguese, without any restrictions on publication date. Cases reports, editorials and literature reviews were not included. The risk of bias was assessed using the Cochrane Collaboration tool. From the initial 7,147 studies, 2,745 were removed as duplicates and 4,382 were excluded after a title/abstract screen.

Results: Seventeen in vitro studies were included. The results showed that the higher the concentration of sodium hypochlorite, the lower the bond strength at dentine/restoration interface (p⟨0.01). Among the studies, sodium ascorbate was the most widely used neutralizer and showed the most significant results in increasing bond strength (p⟨0.01). The bond strength values were found to increase with longer application time of the neutralizing substances (p⟨0.01).

Conclusions: The use of sodium ascorbate as a neutralizing agent can reverse the negative effects of the sodium hypochlorite and improve the bond strength between dentine and resin cement, however, it isn't possible to determine the best protocol for use.

导言:本系统性综述研究了中和剂对次氯酸钠灌洗后粘接强度的影响以及文献中的现有方案:本研究遵循 PRISMA 指南,并在 PROSPERO 网站注册。检索了五个电子数据库(2020 年 9 月/2021 年 1 月),语言包括英语、西班牙语和葡萄牙语,对出版日期没有任何限制。不包括病例报告、社论和文献综述。使用 Cochrane 协作工具对偏倚风险进行了评估。在最初的 7,147 项研究中,2,745 项因重复而被删除,4,382 项在标题/摘要筛选后被排除:结果:共纳入 17 项体外研究。结果显示,次氯酸钠浓度越高,牙本质/修复界面的粘接强度越低(p⟨0.01)。在这些研究中,抗坏血酸钠是使用最广泛的中和剂,在增加粘接强度方面显示出最显著的效果(p⟨0.01)。随着中和剂使用时间的延长,粘接强度值也会增加(p⟨0.01):使用抗坏血酸钠作为中和剂可以逆转次氯酸钠的负面影响,提高牙本质和树脂粘结剂之间的粘结强度,但目前还无法确定最佳的使用方案。
{"title":"Influence of the Use of Irrigation Solution Inhibitors in Improving Dentine Adhesion: A Systematic Review and Meta-Analysis.","authors":"F Z Pierre, L C L Gomes, G B Minhoto, M C Valera, R M de Melo, E Bresciani","doi":"10.1922/EJPRD_2526Pierre17","DOIUrl":"10.1922/EJPRD_2526Pierre17","url":null,"abstract":"<p><strong>Introduction: </strong>This systematic review examined the effect of neutralizing agents on bond strength after irrigation with sodium hypochlorite and their existing protocols in literature.</p><p><strong>Methods: </strong>This present study adhered to the PRISMA guidelines and was registered at PROSPERO. Five electronic databases were searched (sept-2020/jan-2021) in English, Spanish, and Portuguese, without any restrictions on publication date. Cases reports, editorials and literature reviews were not included. The risk of bias was assessed using the Cochrane Collaboration tool. From the initial 7,147 studies, 2,745 were removed as duplicates and 4,382 were excluded after a title/abstract screen.</p><p><strong>Results: </strong>Seventeen in vitro studies were included. The results showed that the higher the concentration of sodium hypochlorite, the lower the bond strength at dentine/restoration interface (p⟨0.01). Among the studies, sodium ascorbate was the most widely used neutralizer and showed the most significant results in increasing bond strength (p⟨0.01). The bond strength values were found to increase with longer application time of the neutralizing substances (p⟨0.01).</p><p><strong>Conclusions: </strong>The use of sodium ascorbate as a neutralizing agent can reverse the negative effects of the sodium hypochlorite and improve the bond strength between dentine and resin cement, however, it isn't possible to determine the best protocol for use.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"28-44"},"PeriodicalIF":1.3,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9827668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
European Journal of Prosthodontics and Restorative Dentistry
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1