Titanium Dioxide/Graphene Oxide Composite Coatings for 316 Stainless Steel Dental Implants. 316不锈钢牙种植体的二氧化钛/氧化石墨烯复合涂层。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2511Al-Noaman15
A S Al-Noaman, S F Rawlinson

Stainless steel has been used in orthopedics and orthodontic fields. However, it cannot be used for fabrication of dental implants due to its inertness, low biocompatibility and weak resistance to corrosion. A composite coating of titanium oxide /graphene oxide has been prepared for stainless steel to improve its biological properties. Stainless steel discs were polished, cleaned and pre-treated with a mixture of HNO3 and HF acid for 15 min. The composite coating composed of TiO2 produced by sol-gel technique and doped with 0.75 wt% graphene oxide. XRD, SEM-EDX and AFM were employed to characterize the composite coating. The anti-bacterial action of the composite coating was investigated against S. aureus and E. coli. The corrosion resistance of coated and noncoated samples was assessed in SBF using electrochemical technique. Cytotoxicity was assessed using osteoblast-like cells. The wettability was determined by contact angle, and bioactivity assessed by immersion in SBF. The results revealed that the composite coating was dense with few micro-cracks, and was not cytotoxic to osteoblast-like cells. The composite coating reduced bacterial colonies and the corrosion rate of the steel was improved. The wettability of the sample was increased with the composite coating and apatite formation appeared after 21 days.

不锈钢已被用于矫形和正畸领域。然而,由于其惰性、生物相容性低、耐腐蚀性弱,不能用于牙科种植体的制造。为提高不锈钢的生物性能,制备了氧化钛/氧化石墨烯复合涂层。用HNO3和HF酸的混合物对不锈钢片进行抛光、清洗和预处理15 min。采用溶胶-凝胶法制备TiO2,掺杂0.75 wt%氧化石墨烯,制备复合涂层。采用XRD、SEM-EDX和AFM对复合涂层进行表征。研究了复合涂层对金黄色葡萄球菌和大肠杆菌的抑菌作用。采用电化学技术对涂覆和未涂覆样品的耐蚀性进行了评价。使用成骨细胞样细胞评估细胞毒性。通过接触角测定润湿性,浸泡在SBF中评价生物活性。结果表明,复合涂层致密,微裂纹少,对成骨样细胞无细胞毒性。复合涂层减少了细菌菌落,提高了钢的腐蚀速度。复合涂层提高了样品的润湿性,并在21天后形成磷灰石。
{"title":"Titanium Dioxide/Graphene Oxide Composite Coatings for 316 Stainless Steel Dental Implants.","authors":"A S Al-Noaman, S F Rawlinson","doi":"10.1922/EJPRD_2511Al-Noaman15","DOIUrl":"10.1922/EJPRD_2511Al-Noaman15","url":null,"abstract":"<p><p>Stainless steel has been used in orthopedics and orthodontic fields. However, it cannot be used for fabrication of dental implants due to its inertness, low biocompatibility and weak resistance to corrosion. A composite coating of titanium oxide /graphene oxide has been prepared for stainless steel to improve its biological properties. Stainless steel discs were polished, cleaned and pre-treated with a mixture of HNO3 and HF acid for 15 min. The composite coating composed of TiO2 produced by sol-gel technique and doped with 0.75 wt% graphene oxide. XRD, SEM-EDX and AFM were employed to characterize the composite coating. The anti-bacterial action of the composite coating was investigated against S. aureus and E. coli. The corrosion resistance of coated and noncoated samples was assessed in SBF using electrochemical technique. Cytotoxicity was assessed using osteoblast-like cells. The wettability was determined by contact angle, and bioactivity assessed by immersion in SBF. The results revealed that the composite coating was dense with few micro-cracks, and was not cytotoxic to osteoblast-like cells. The composite coating reduced bacterial colonies and the corrosion rate of the steel was improved. The wettability of the sample was increased with the composite coating and apatite formation appeared after 21 days.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10188450","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Strength of a Zirconia- Reinforced Glass-Ceramic After Diamond Bur Adjustment. 一种氧化锆增强玻璃陶瓷在金刚石钎剂调整后的强度。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2468MouraPereira09
B Moura Pereira, A Restani Oliveira, R Leal do Prado, A B Gomes de Carvalho, R Marques de Melo, K Singh Jodha, S M Salazar Marocho, G Ávila Galhano

Introduction: Adjustments with diamond burs on the ceramic surface can affect its roughness and decrease flexural strength. This study evaluated the effect of polishing or glazing on the surface roughness and biaxial flexural strength of a zirconia-reinforced lithium silicate glass-ceramic upon adjustment with diamond burs.

Methods: Seventy disks were prepared according to ISO 6872 and divided into seven groups (n = 10) according to different adjustments and finishing processes. Surface roughness was measured prior to biaxial flexural strength testing. The topography was analyzed using an atomic force microscope , fracture markings were identified using a stereomicroscope and representative specimens were analyzed using scanning electron microscopy.

Results: The use of diamond burs significantly increased the surface roughness and decreased the strength of the evaluated ceramic (p⟨0.05). Polishing reduced the ceramic's roughness but resulted in flexural strength similar to that of the groups with wear (p⟩0.05). The glaze-treated specimens showed flexural strength statistically similar to the control group (p>0.05) but higher roughness, similar to those with wear.

Conclusions: Polishing reduced the surface roughness but did not affect the biaxial flexural strength of the ZLS ceramic. At the same time, the application of glaze after wear increased the strength.

导读:金刚石毛刺在陶瓷表面的调整会影响其粗糙度并降低其弯曲强度。本研究评估了抛光或上釉对氧化锆增强硅酸锂玻璃陶瓷表面粗糙度和双轴抗折强度的影响。方法:按ISO 6872标准制备光盘70张,按调整和整理工艺不同分为7组(n = 10)。在双轴弯曲强度测试之前测量表面粗糙度。用原子力显微镜分析形貌,用体视显微镜识别断口痕迹,用扫描电镜分析代表性试样。结果:金刚石毛刺的使用显著增加了表面粗糙度并降低了评估陶瓷的强度(p⟨0.05)。抛光降低了陶瓷的粗糙度,但导致弯曲强度与磨损组相似(p⟩0.05)。釉面处理试样的抗弯强度与对照组相似(p>0.05),但粗糙度较高,与磨损试样相似。结论:抛光降低了ZLS陶瓷的表面粗糙度,但不影响其双轴抗折强度。同时,磨耗后的釉料的应用提高了强度。
{"title":"Strength of a Zirconia- Reinforced Glass-Ceramic After Diamond Bur Adjustment.","authors":"B Moura Pereira, A Restani Oliveira, R Leal do Prado, A B Gomes de Carvalho, R Marques de Melo, K Singh Jodha, S M Salazar Marocho, G Ávila Galhano","doi":"10.1922/EJPRD_2468MouraPereira09","DOIUrl":"10.1922/EJPRD_2468MouraPereira09","url":null,"abstract":"<p><strong>Introduction: </strong>Adjustments with diamond burs on the ceramic surface can affect its roughness and decrease flexural strength. This study evaluated the effect of polishing or glazing on the surface roughness and biaxial flexural strength of a zirconia-reinforced lithium silicate glass-ceramic upon adjustment with diamond burs.</p><p><strong>Methods: </strong>Seventy disks were prepared according to ISO 6872 and divided into seven groups (n = 10) according to different adjustments and finishing processes. Surface roughness was measured prior to biaxial flexural strength testing. The topography was analyzed using an atomic force microscope , fracture markings were identified using a stereomicroscope and representative specimens were analyzed using scanning electron microscopy.</p><p><strong>Results: </strong>The use of diamond burs significantly increased the surface roughness and decreased the strength of the evaluated ceramic (p⟨0.05). Polishing reduced the ceramic's roughness but resulted in flexural strength similar to that of the groups with wear (p⟩0.05). The glaze-treated specimens showed flexural strength statistically similar to the control group (p>0.05) but higher roughness, similar to those with wear.</p><p><strong>Conclusions: </strong>Polishing reduced the surface roughness but did not affect the biaxial flexural strength of the ZLS ceramic. At the same time, the application of glaze after wear increased the strength.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9696478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accuracy of Static Computer- Assisted Implant Placement in Posterior Edentulous Areas with Different Levels of Tooth- Support by Novice Clinicians. 临床新手在不同牙支撑水平的后牙无牙区进行静态计算机辅助种植的准确性。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2494Abduo10
J Abduo, D Lau

Correct implant placement is necessary for satisfactory implant restoration. Therefore, the use of surgical guide is recommended. This study evaluated the accuracy of implant placement in posterior edentulous areas with different levels of tooth-support by novice clinicians according to fully-guided (FG), pilot-guided (PG), and freehand (FH) placement protocols. A mandibular model with missing first molars was designed. On one side, the model had a bound edentulous area (BEA), and on the other side, a free end edentulous area (FEA). Fourteen clinicians new to implant dentistry participated in the study, and each clinician inserted an implant in the BEA and FEA sites for every placement protocol. Angle, vertical and maximum horizontal platform and apex deviations were measured. The FG placement was more accurate than the PG and FH placements. This was significant for BEA angle deviation, BEA and FEA maximum horizontal platform deviations, and BEA maximum horizontal apex deviation. The PG placement was significantly more accurate than the FH placement for BEA and FEA maximum horizontal platform deviations. FG shows significantly greater angle, maximum horizontal platform and maximum horizontal apex deviations at FEA than BEA. This can be attributed to reduced guide support and the possibility of guide displacement during surgery.

正确的种植体放置是获得满意种植体修复的必要条件。因此,建议使用手术指南。本研究评估了临床新手根据全引导(FG)、导航引导(PG)和徒手(FH)放置方案在不同牙支持水平的后牙无牙区种植体放置的准确性。设计了缺失第一磨牙的下颌模型。模型的一侧为边界无牙区(BEA),另一侧为自由端无牙区(FEA)。14位临床医生参与了这项研究,每位临床医生在BEA和FEA位置插入种植体。测量角度、垂直和最大水平平台和顶点偏差。FG放置比PG和FH放置更准确。这在BEA角偏差、BEA和FEA最大水平平台偏差和BEA最大水平顶点偏差上具有显著性。对于BEA和FEA最大水平平台偏差,PG定位明显比FH定位更准确。在有限元分析中,FG的角度、最大水平平台和最大水平顶点偏差明显大于BEA。这可归因于手术过程中减少的引导支撑和引导移位的可能性。
{"title":"Accuracy of Static Computer- Assisted Implant Placement in Posterior Edentulous Areas with Different Levels of Tooth- Support by Novice Clinicians.","authors":"J Abduo, D Lau","doi":"10.1922/EJPRD_2494Abduo10","DOIUrl":"10.1922/EJPRD_2494Abduo10","url":null,"abstract":"<p><p>Correct implant placement is necessary for satisfactory implant restoration. Therefore, the use of surgical guide is recommended. This study evaluated the accuracy of implant placement in posterior edentulous areas with different levels of tooth-support by novice clinicians according to fully-guided (FG), pilot-guided (PG), and freehand (FH) placement protocols. A mandibular model with missing first molars was designed. On one side, the model had a bound edentulous area (BEA), and on the other side, a free end edentulous area (FEA). Fourteen clinicians new to implant dentistry participated in the study, and each clinician inserted an implant in the BEA and FEA sites for every placement protocol. Angle, vertical and maximum horizontal platform and apex deviations were measured. The FG placement was more accurate than the PG and FH placements. This was significant for BEA angle deviation, BEA and FEA maximum horizontal platform deviations, and BEA maximum horizontal apex deviation. The PG placement was significantly more accurate than the FH placement for BEA and FEA maximum horizontal platform deviations. FG shows significantly greater angle, maximum horizontal platform and maximum horizontal apex deviations at FEA than BEA. This can be attributed to reduced guide support and the possibility of guide displacement during surgery.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9840678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of Clinical Periodontal Parameters of Abutment Teeth Supporting Distal-Extension Base Removable Partial Dentures: A Cross-sectional Study. 基牙支持远伸基托可摘局部义齿的临床牙周参数评价:一项横断面研究。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2500AlDwairi09
Z N Al-Dwairi, D S Taani, A Z Naseeb, N Al-Haj Husain, M Özcan, E Lynch

To assess the clinical periodontal status of abutment teeth in regards of different design components of distal-extension removable partial dentures. Subjects (N=100) with acrylic or cobalt-chromium distal-extension removable partial dentures were enrolled and their periodontal parameters plaque and gingival indices [PI, GI], probing depths [PD], clinical attachment loss [CAL] and a mobility index [MI] evaluated. Denture base type, major connector, occlusal rests position, design of direct retainers, retention, stability and denture wearing habits were further evaluated. Acrylic RPDs were associated with higher mean±SE PI [1.70±0.74], GI [1.76±0.55], PD scores [2.47±1.02 mm] and CAL values [4.46±2.11 mm] compared to CO-CR RPDs [p⟨0.05]. For abutments, the PI [1.6±0.83], GI [1.72±0.57], PD [2.32±1.03] and CAL [4.26±2.08] were higher than their non-abutments counterparts [p⟨0.05]. CAL scores were found to be significantly higher for mandibular abutments compared to maxillary ones [P=0.002]. The highest PI [1.83±1.10] and GI [2.00±0.00] scores were associated with lingual bars and horse-shoe connectors, respectively. Full palatal coverage and lingual plates were associated with the highest PD [2.80±0.48] and CAL [4.70±0.37] scores. Acrylic RPDs, type of major connector, wrought wire clasps and distal occlusal rests may be considered as risk factors for periodontal disease progression in distal-extension removable partial denture wearers.

目的探讨不同设计的远端可摘局部义齿对基牙牙周状况的影响。使用丙烯酸或钴铬远端可摘局部义齿的受试者(N=100),评估其牙周参数菌斑和牙龈指数[PI, GI]、探探深度[PD]、临床附着丧失[CAL]和活动指数[MI]。进一步评价义齿基托类型、主要接头、咬合托架位置、直接固位器设计、固位、稳定性和义齿佩戴习惯。与CO-CR rpd相比,丙烯酸rpd的平均±SE PI[1.70±0.74]、GI[1.76±0.55]、PD评分[2.47±1.02 mm]和CAL值[4.46±2.11 mm]均较高[p⟨0.05]。有基牙组的PI[1.6±0.83]、GI[1.72±0.57]、PD[2.32±1.03]、CAL[4.26±2.08]均高于无基牙组[p⟨0.05]。下颌基牙的CAL评分明显高于上颌基牙[P=0.002]。PI(1.83±1.10)和GI(2.00±0.00)分别与舌棒和马蹄形接头相关。全腭覆盖和舌板与最高PD[2.80±0.48]和CAL[4.70±0.37]评分相关。丙烯酸树脂rpd、主接头类型、锻丝卡环和远端咬合托可能被认为是远端可摘局部义齿佩戴者牙周疾病进展的危险因素。
{"title":"Evaluation of Clinical Periodontal Parameters of Abutment Teeth Supporting Distal-Extension Base Removable Partial Dentures: A Cross-sectional Study.","authors":"Z N Al-Dwairi, D S Taani, A Z Naseeb, N Al-Haj Husain, M Özcan, E Lynch","doi":"10.1922/EJPRD_2500AlDwairi09","DOIUrl":"10.1922/EJPRD_2500AlDwairi09","url":null,"abstract":"<p><p>To assess the clinical periodontal status of abutment teeth in regards of different design components of distal-extension removable partial dentures. Subjects (N=100) with acrylic or cobalt-chromium distal-extension removable partial dentures were enrolled and their periodontal parameters plaque and gingival indices [PI, GI], probing depths [PD], clinical attachment loss [CAL] and a mobility index [MI] evaluated. Denture base type, major connector, occlusal rests position, design of direct retainers, retention, stability and denture wearing habits were further evaluated. Acrylic RPDs were associated with higher mean±SE PI [1.70±0.74], GI [1.76±0.55], PD scores [2.47±1.02 mm] and CAL values [4.46±2.11 mm] compared to CO-CR RPDs [p⟨0.05]. For abutments, the PI [1.6±0.83], GI [1.72±0.57], PD [2.32±1.03] and CAL [4.26±2.08] were higher than their non-abutments counterparts [p⟨0.05]. CAL scores were found to be significantly higher for mandibular abutments compared to maxillary ones [P=0.002]. The highest PI [1.83±1.10] and GI [2.00±0.00] scores were associated with lingual bars and horse-shoe connectors, respectively. Full palatal coverage and lingual plates were associated with the highest PD [2.80±0.48] and CAL [4.70±0.37] scores. Acrylic RPDs, type of major connector, wrought wire clasps and distal occlusal rests may be considered as risk factors for periodontal disease progression in distal-extension removable partial denture wearers.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9624581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Thickness and Translucency on Color Change and Masking Ability of Ceramic Materials used for Laminate Veneers. 厚度和半透明度对复合单板陶瓷材料颜色变化和遮盖能力的影响。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2501Ayata08
M Ayata, K Kilic, N Al-Haj Husain, M Özcan

This study evaluated the effect of the thickness and translucency of lithium disilicatebased glass ceramics on resin composite substrates on color change and masking effect. Laminate veneers were fabricated using IPS e.max CAD (A1) blocks with two different light transmittance values (High translucent [HT], Low translucent [LT]). Slices of two different thicknesses (0.3 mm, 0.5 mm) were obtained (n=10) and laminate veneers were cemented on the resin composite substrates of two different shades (A2, A3.5). The color change (ΔE values) was evaluated with the CIELab color system using a spectrophotometer, while the masking effect was calculated. The data were analyzed using independent-samples t-test and two-way analysis of variance. The ceramic thickness and translucency had a significant effect on final color and masking. When HT was used, and the laminate veneer thickness decreased (0.3 mm), the masking effect in ΔE values were lower (p⟨0.05). The ΔE values (⟩3.7) were clinically unacceptable. With the increase in thickness, translucency of porcelain laminate veneers decreases showing better color masking ability. Veneer thickness seems to be more effective on the restoration's masking ability than the shade of the substrate and translucency. Cinically, in case a 0.5-mm or thinner laminate veneer is planned, tooth color, resin cement and ceramic type should be considered.

本研究考察了二硅酸锂基玻璃陶瓷在树脂复合基板上的厚度和透明度对颜色变化和掩蔽效应的影响。层压单板使用IPS e.max CAD (A1)块,具有两种不同的透光率值(高半透明[HT],低半透明[LT])。获得两种不同厚度(0.3 mm, 0.5 mm)的薄片(n=10),并将层压单板粘合在两种不同色调(A2, A3.5)的树脂复合基材上。采用CIELab颜色系统,利用分光光度计评估颜色变化(ΔE值),同时计算掩蔽效应。数据分析采用独立样本t检验和双向方差分析。陶瓷的厚度和透明度对最终的颜色和掩模有显著的影响。当使用HT时,层压单板厚度减小(0.3 mm), ΔE值的掩蔽效应降低(p⟨0.05)。ΔE值(⟩3.7)在临床上是不可接受的。随着厚度的增加,瓷单板的透光率降低,显示出较好的遮盖能力。与基材的阴影和半透明相比,单板厚度似乎对修复的掩蔽能力更有效。临床上,如果计划使用0.5 mm或更薄的层压板贴面,则应考虑牙齿颜色,树脂水泥和陶瓷类型。
{"title":"Effect of Thickness and Translucency on Color Change and Masking Ability of Ceramic Materials used for Laminate Veneers.","authors":"M Ayata, K Kilic, N Al-Haj Husain, M Özcan","doi":"10.1922/EJPRD_2501Ayata08","DOIUrl":"10.1922/EJPRD_2501Ayata08","url":null,"abstract":"<p><p>This study evaluated the effect of the thickness and translucency of lithium disilicatebased glass ceramics on resin composite substrates on color change and masking effect. Laminate veneers were fabricated using IPS e.max CAD (A1) blocks with two different light transmittance values (High translucent [HT], Low translucent [LT]). Slices of two different thicknesses (0.3 mm, 0.5 mm) were obtained (n=10) and laminate veneers were cemented on the resin composite substrates of two different shades (A2, A3.5). The color change (ΔE values) was evaluated with the CIELab color system using a spectrophotometer, while the masking effect was calculated. The data were analyzed using independent-samples t-test and two-way analysis of variance. The ceramic thickness and translucency had a significant effect on final color and masking. When HT was used, and the laminate veneer thickness decreased (0.3 mm), the masking effect in ΔE values were lower (p⟨0.05). The ΔE values (⟩3.7) were clinically unacceptable. With the increase in thickness, translucency of porcelain laminate veneers decreases showing better color masking ability. Veneer thickness seems to be more effective on the restoration's masking ability than the shade of the substrate and translucency. Cinically, in case a 0.5-mm or thinner laminate veneer is planned, tooth color, resin cement and ceramic type should be considered.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10584513","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The Effect of Colloidal Silica and Glaze Coatings on the Adhesion of Zirconia with Various Ytrria Concentration. 胶体二氧化硅和釉膜对不同钇浓度氧化锆附着力的影响。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2491Villanova12
M Villanova, M Carvalho Prado, Y Neves, E Annese, B Archanjo, R Simão, H E Dos Santos, M Prado

Purpose: This study evaluated the effect of coating traditional and translucent Y-TZP with an industrial nanometric colloidal silica or glaze before or after sintering on the adhesion of zirconia with various ytrria concentration.

Materials and methods: Specimens of Y-TZP with 3% and 5% yttria were subdivided into 5 groups (n=10), according to the coating applied and moment of application (before or after Y-TZP sintering): Control (no coating), Colloidal Silica/Sintering, Sintering/Colloidal Silica, Glaze/Sintering, Sintering/ Glaze. Lithium disilicate (LD) was used as positive control. Except for Y-TZP controls, groups were conditioned with silane before cementation with a self-adhesive resin cement. After 24 hours, the shear bond strength and failure analysis were performed. Also, analysis of specimens' surface was accomplished with SEM-EDX. Kruskal-Wallis and Dunn tests were applied to analyze differences between groups (p⟨0.05).

Results: Overall, the worst and best values of shear bond strength test were control and glaze after sintering groups. Different morphological and chemical aspects were observed in SEM-EDX analysis.

Conclusions: Coating Y-TZP with colloidal silica showed unsatisfactory results. In 3Y-TZP, the surface treatment associated with the best adhesion values was the application of glaze after zirconia sintering. However, in 5Y-TZP, glaze application can be performed before or after the zirconia sintering to optimize clinical steps.

目的:研究在烧结前后用工业纳米二氧化硅胶体或釉料涂覆传统的和半透明的Y-TZP对不同氧化钇浓度氧化锆的附着力的影响。材料与方法:将钇含量为3%和5%的Y-TZP试样,根据涂覆涂层和涂覆时刻(Y-TZP烧结前后)分为5组(n=10):对照(未涂覆)、硅溶胶/烧结、硅溶胶/烧结、釉料/烧结、烧结/釉料。以二硅酸锂(LD)为阳性对照。除Y-TZP对照组外,各组在用自粘树脂水泥胶结前用硅烷进行条件处理。24h后进行剪切粘结强度及破坏分析。同时,利用SEM-EDX对试样表面进行了分析。采用Kruskal-Wallis和Dunn检验分析组间差异(p⟨0.05)。结果:总体而言,烧结后釉料组和对照组的剪切强度测试结果最差、最佳。在SEM-EDX分析中观察到不同的形态和化学方面。结论:硅胶胶体包覆Y-TZP效果不理想。在3Y-TZP中,与最佳附着力值相关的表面处理是在氧化锆烧结后应用釉料。然而,在5Y-TZP中,釉面应用可以在氧化锆烧结之前或之后进行,以优化临床步骤。
{"title":"The Effect of Colloidal Silica and Glaze Coatings on the Adhesion of Zirconia with Various Ytrria Concentration.","authors":"M Villanova, M Carvalho Prado, Y Neves, E Annese, B Archanjo, R Simão, H E Dos Santos, M Prado","doi":"10.1922/EJPRD_2491Villanova12","DOIUrl":"10.1922/EJPRD_2491Villanova12","url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the effect of coating traditional and translucent Y-TZP with an industrial nanometric colloidal silica or glaze before or after sintering on the adhesion of zirconia with various ytrria concentration.</p><p><strong>Materials and methods: </strong>Specimens of Y-TZP with 3% and 5% yttria were subdivided into 5 groups (n=10), according to the coating applied and moment of application (before or after Y-TZP sintering): Control (no coating), Colloidal Silica/Sintering, Sintering/Colloidal Silica, Glaze/Sintering, Sintering/ Glaze. Lithium disilicate (LD) was used as positive control. Except for Y-TZP controls, groups were conditioned with silane before cementation with a self-adhesive resin cement. After 24 hours, the shear bond strength and failure analysis were performed. Also, analysis of specimens' surface was accomplished with SEM-EDX. Kruskal-Wallis and Dunn tests were applied to analyze differences between groups (p⟨0.05).</p><p><strong>Results: </strong>Overall, the worst and best values of shear bond strength test were control and glaze after sintering groups. Different morphological and chemical aspects were observed in SEM-EDX analysis.</p><p><strong>Conclusions: </strong>Coating Y-TZP with colloidal silica showed unsatisfactory results. In 3Y-TZP, the surface treatment associated with the best adhesion values was the application of glaze after zirconia sintering. However, in 5Y-TZP, glaze application can be performed before or after the zirconia sintering to optimize clinical steps.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9693817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Different Digital Color Measurement Methods on Maxillary Anterior and Canine Teeth: A Clinical Observational Study. 上颌前牙与犬牙不同数字测色方法的临床观察研究。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2541Oberruck08
N Oberück, P Leussner, S Rinke, T Kottmann, R Haak, D Ziebolz

Purpose: This clinical observational study aimed to determine the reproducibility of digital color measurement methods of different front teeth.

Methods: Color determination was performed using two spectrophotometric systems (Easyshade Advance; ES and Shadepilot; SP) and digital photography using a camera with ring flash and gray card with subsequent evaluation using computer software (DP; Adobe Photoshop). In 50 patients, at two time points, a digital color determination was performed on maxillary central incisors (MCI) and maxillary canines (MC) by a calibrated examiner. Outcome parameters were: color difference ΔE based on CIE L*a*b* values and VITA color match given by spectrophotometers.

Results: SP showed significantly lower median ΔE values (⟨1.2) than ES (⟨3.5) and DP (⟨4.4), while no significant differences were found between ES and DP. For all methods, both ΔE values and VITA color showed lower reliability regarding MC compared with MCI. The ΔE examination of subareas revealed significant differences in MCI for all devices and in MC only for SP. When comparing VITA color stability, SP showed a significantly higher color match than ES (81% and 57%, respectively).

Conclusions: Digital color determination methods tested in the current study provided reliable results. However, there are significant differences between the devices used and the teeth examined.

目的:本临床观察研究旨在确定不同门牙数字测色方法的可重复性。方法:采用两种分光光度法(Easyshade Advance;ES和Shadepilot;SP)和数码摄影,使用带环形闪光和灰卡的相机,随后使用计算机软件(DP;Adobe Photoshop)。在50例患者中,在两个时间点,由校准的检查员对上颌中切牙(MCI)和上颌犬齿(MC)进行数字颜色测定。结果参数为:色差ΔE基于CIE L*a*b*值和分光光度计给出的VITA颜色匹配。结果:SP的ΔE中位值⟨1.2)明显低于ES(⟨3.5)和DP(⟨4.4),而ES和DP之间无显著差异。在所有方法中,与MCI相比,ΔE值和VITA颜色对MC的可靠性都较低。ΔE对子区域的检查显示,所有设备的MCI和SP的MC都有显著差异。当比较VITA颜色稳定性时,SP的颜色匹配度明显高于ES(分别为81%和57%)。结论:本研究中所测试的数字颜色测定方法提供了可靠的结果。然而,所使用的设备和所检查的牙齿之间存在显著差异。
{"title":"Comparison of Different Digital Color Measurement Methods on Maxillary Anterior and Canine Teeth: A Clinical Observational Study.","authors":"N Oberück, P Leussner, S Rinke, T Kottmann, R Haak, D Ziebolz","doi":"10.1922/EJPRD_2541Oberruck08","DOIUrl":"10.1922/EJPRD_2541Oberruck08","url":null,"abstract":"<p><strong>Purpose: </strong>This clinical observational study aimed to determine the reproducibility of digital color measurement methods of different front teeth.</p><p><strong>Methods: </strong>Color determination was performed using two spectrophotometric systems (Easyshade Advance; ES and Shadepilot; SP) and digital photography using a camera with ring flash and gray card with subsequent evaluation using computer software (DP; Adobe Photoshop). In 50 patients, at two time points, a digital color determination was performed on maxillary central incisors (MCI) and maxillary canines (MC) by a calibrated examiner. Outcome parameters were: color difference ΔE based on CIE L*a*b* values and VITA color match given by spectrophotometers.</p><p><strong>Results: </strong>SP showed significantly lower median ΔE values (⟨1.2) than ES (⟨3.5) and DP (⟨4.4), while no significant differences were found between ES and DP. For all methods, both ΔE values and VITA color showed lower reliability regarding MC compared with MCI. The ΔE examination of subareas revealed significant differences in MCI for all devices and in MC only for SP. When comparing VITA color stability, SP showed a significantly higher color match than ES (81% and 57%, respectively).</p><p><strong>Conclusions: </strong>Digital color determination methods tested in the current study provided reliable results. However, there are significant differences between the devices used and the teeth examined.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9696476","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Evaluation of Apically Extruded Debris During Root Canal Preparation Using Three Different File Systems Applied Under 2.5% Sodium Hypochlorite or 2% CHX Irrigation. 在2.5%次氯酸钠或2% CHX灌溉条件下,三种不同文件系统对根管预备过程中根尖挤压碎片的比较评价。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2499Zareana07
P Zarean, M Özcan, M Molaie, A Mortaheb, N Al-Haj Husain, H Molaeinasab, M Zare Jahromi, P Zarean

The chemomechanical cleaning of the root canal system is performed using manual and rotary files. This study aimed to compare the effect of ProTaper, Reciproc and HyFlex rotary files considering 2.5% sodium hypochlorite and 2% chlorhexidine (CHX) as irrigating solutions on apical extrusion of intracanal debris. Single-canal mandibular premolars (N=165) were evaluated. The teeth were divided into 6 experimental groups (N=25) for root canal instrumentation using 3 file systems, (Reciproc, HyFlex and ProTaper) and two irrigation solutions, namely 2.5% sodium hypochlorite or 2% CHX. Fifteen teeth were also assigned into three control groups (n=5) with saline as irrigation solution. Eppendorf tubes were weighed and the teeth were placed inside. The canals were instrumented and the tubes weighed to determine the dry weight of extruded debris. Data were analyzed using one-way ANOVA and Bonferroni test (α=0.05). The mean amount of extruded debris using the sodium hypochlorite solution was significantly higher than other irrigating solutions (p⟨0.001). The mean amount of extruded debris using the Reciproc file system was significantly higher compared to ProTaper and HyFlex (p⟨0.001). The use of the sodium hypochlorite solution, single-file systems and reciprocal movement are associated with higher debris extrusion and might be associated with higher risk of postoperative pain.

化学机械清洁的根管系统是使用手动和旋转锉。本研究旨在比较2.5%次氯酸钠和2%氯己定(CHX)作为冲洗溶液的ProTaper、Reciproc和HyFlex旋转锉对管内碎片根尖挤压的影响。评估单管下颌前磨牙(N=165)。采用3种锉制(Reciproc、HyFlex和ProTaper)和2种灌洗液(2.5%次氯酸钠或2% CHX)进行根管预备,分为6组(N=25)。15颗牙分为3个对照组(n=5),以生理盐水为冲洗液。对埃彭多夫管进行称重,并将牙齿放入其中。对管道进行仪器测量,对管道称重以确定挤压碎片的干重。数据分析采用单因素方差分析和Bonferroni检验(α=0.05)。次氯酸钠溶液挤出碎片的平均量显著高于其他冲洗溶液(p⟨0.001)。与ProTaper和HyFlex相比,Reciproc文件系统的平均挤出碎片量明显更高(p⟨0.001)。使用次氯酸钠溶液、单锉系统和相互运动与较高的碎片挤压有关,并可能与较高的术后疼痛风险有关。
{"title":"Comparative Evaluation of Apically Extruded Debris During Root Canal Preparation Using Three Different File Systems Applied Under 2.5% Sodium Hypochlorite or 2% CHX Irrigation.","authors":"P Zarean, M Özcan, M Molaie, A Mortaheb, N Al-Haj Husain, H Molaeinasab, M Zare Jahromi, P Zarean","doi":"10.1922/EJPRD_2499Zareana07","DOIUrl":"10.1922/EJPRD_2499Zareana07","url":null,"abstract":"<p><p>The chemomechanical cleaning of the root canal system is performed using manual and rotary files. This study aimed to compare the effect of ProTaper, Reciproc and HyFlex rotary files considering 2.5% sodium hypochlorite and 2% chlorhexidine (CHX) as irrigating solutions on apical extrusion of intracanal debris. Single-canal mandibular premolars (N=165) were evaluated. The teeth were divided into 6 experimental groups (N=25) for root canal instrumentation using 3 file systems, (Reciproc, HyFlex and ProTaper) and two irrigation solutions, namely 2.5% sodium hypochlorite or 2% CHX. Fifteen teeth were also assigned into three control groups (n=5) with saline as irrigation solution. Eppendorf tubes were weighed and the teeth were placed inside. The canals were instrumented and the tubes weighed to determine the dry weight of extruded debris. Data were analyzed using one-way ANOVA and Bonferroni test (α=0.05). The mean amount of extruded debris using the sodium hypochlorite solution was significantly higher than other irrigating solutions (p⟨0.001). The mean amount of extruded debris using the Reciproc file system was significantly higher compared to ProTaper and HyFlex (p⟨0.001). The use of the sodium hypochlorite solution, single-file systems and reciprocal movement are associated with higher debris extrusion and might be associated with higher risk of postoperative pain.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9566101","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impact of Finishing and Polishing Procedures on CAD/CAM In Vitro Milled Ceramics Surfaces: A Systematic Review. 精加工和抛光工艺对CAD/CAM体外铣削陶瓷表面的影响:系统综述。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2520Canceill11
T Canceill, J Lacroux, C Bataille, J Delrieu, K Nasr, F Diemer, R Esclassan

Introduction and objectives: CAD/CAM prostheses may be produced in prosthetic laboratories or directly by practitioners. Quality of ceramic polishing procedures is a controversial topic and it would be interesting for practitioners working with CAD/CAM devices to determine which method is the most efficient regarding finishing and polishing. This systematic review aims to evaluate the impact of different finishing and polishing procedures on the surface of milled ceramics.

Materials and methods: A precise request was launched on the PubMed database. Studies included if they met the criteria of a specifically prepared PICO search. A first selection was performed by analysing titles and abstracts: the articles presenting a study conducted on non-CAD/CAM milled ceramics and research not containing comparisons of finishing procedures were not included. Roughness was evaluated in 15 articles. Nine papers recommended mechanical polishing over glazing regardless of the type of ceramic used. However, no significant differences were detected between the surface roughness of glazed and polished ceramics in nine other publications.

Conclusions: there is no scientific evidence demonstrating the superiority of hand polishing over glazing on CAD/CAM-milled ceramics.

介绍和目的:CAD/CAM假体可以在假体实验室生产,也可以由从业者直接生产。陶瓷抛光程序的质量是一个有争议的话题,对于使用CAD/CAM设备的从业者来说,确定哪种方法在精加工和抛光方面最有效将是一件有趣的事情。本系统综述旨在评价不同的精加工和抛光工艺对铣削陶瓷表面的影响。材料和方法:在PubMed数据库上发起了一个精确的请求。研究包括是否符合特别准备的PICO搜索的标准。第一次选择是通过分析标题和摘要来进行的:不包括对非cad /CAM铣削陶瓷进行研究的文章和不包含精加工程序比较的研究。粗糙度在15篇文章中进行了评估。九篇论文推荐机械抛光而不是上光,无论使用的是哪种陶瓷。然而,在其他九份出版物中,没有发现釉面和抛光陶瓷表面粗糙度之间的显著差异。结论:没有科学证据表明在CAD/ cam铣削陶瓷上手工抛光优于上釉。
{"title":"Impact of Finishing and Polishing Procedures on CAD/CAM In Vitro Milled Ceramics Surfaces: A Systematic Review.","authors":"T Canceill, J Lacroux, C Bataille, J Delrieu, K Nasr, F Diemer, R Esclassan","doi":"10.1922/EJPRD_2520Canceill11","DOIUrl":"10.1922/EJPRD_2520Canceill11","url":null,"abstract":"<p><strong>Introduction and objectives: </strong>CAD/CAM prostheses may be produced in prosthetic laboratories or directly by practitioners. Quality of ceramic polishing procedures is a controversial topic and it would be interesting for practitioners working with CAD/CAM devices to determine which method is the most efficient regarding finishing and polishing. This systematic review aims to evaluate the impact of different finishing and polishing procedures on the surface of milled ceramics.</p><p><strong>Materials and methods: </strong>A precise request was launched on the PubMed database. Studies included if they met the criteria of a specifically prepared PICO search. A first selection was performed by analysing titles and abstracts: the articles presenting a study conducted on non-CAD/CAM milled ceramics and research not containing comparisons of finishing procedures were not included. Roughness was evaluated in 15 articles. Nine papers recommended mechanical polishing over glazing regardless of the type of ceramic used. However, no significant differences were detected between the surface roughness of glazed and polished ceramics in nine other publications.</p><p><strong>Conclusions: </strong>there is no scientific evidence demonstrating the superiority of hand polishing over glazing on CAD/CAM-milled ceramics.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9469707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Factors that Affect the Shear Bond Strength of Pit and Fissure Sealants to Tooth Structure: A Systematic Review. 影响牙槽和牙缝密封剂与牙齿结构剪切结合强度的因素:系统综述。
IF 1.3 Q2 Medicine Pub Date : 2023-11-30 DOI: 10.1922/EJPRD_2503Ferreira14
I Ferreira, J D C Tardelli, A C Dos Reis

Introduction: Pit and fissure sealants are effective in preventing caries disease, however, they may present flaws that damage the physical barrier leading to treatment failure.

Objective: To answer the question ''Do pit and fissure sealants present good adhering to the dental structure when analyzed by their resistance to shear/microshear?".

Methods: This systematic review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) and was recorded in Open Science Framework. Embase, PubMed, SCOPUS, and Web of Science databases were used for the search strategy. The articles were selected according to the eligibility criteria. The risk of bias was performed with the adaptation of the quasi-experimental studies tool by Joanna Briggs Institute (JBI).

Results: 1245 studies were found in the databases when applying the search strategy, after removal of duplicates 881 were evaluated and 44 were selected. After applying the JBI tool, 30 studies presented low risk and 15 moderate risk of bias. Meta-analysis was not possible to performed due to the heterogeneity of the studies.

Conclusion: The adhesion is dependent on the application protocol, and among the protocols evaluated, conditioning with 37% phosphoric acid for 60 seconds and contamination of the substrate, as these can affect sealant adhesion.

导读:牙槽和牙缝密封剂在预防龋齿方面是有效的,然而,它们可能存在缺陷,破坏物理屏障,导致治疗失败。目的:回答“坑沟封闭剂抗剪切/微剪切性能分析是否表现出良好的牙体结构粘附性?”方法:本系统评价遵循系统评价和荟萃分析首选报告项目(PRISMA),并记录在开放科学框架中。Embase、PubMed、SCOPUS和Web of Science数据库被用于搜索策略。文章是根据入选标准选出的。偏倚风险采用乔安娜布里格斯研究所(JBI)的准实验研究工具。结果:应用检索策略在数据库中发现1245项研究,剔除重复项后评估881项,选择44项。应用JBI工具后,30项研究为低风险偏倚,15项为中等风险偏倚。由于研究的异质性,无法进行meta分析。结论:粘附性取决于应用方案,在评估的方案中,37%磷酸处理60秒和基材污染会影响密封剂的粘附性。
{"title":"Factors that Affect the Shear Bond Strength of Pit and Fissure Sealants to Tooth Structure: A Systematic Review.","authors":"I Ferreira, J D C Tardelli, A C Dos Reis","doi":"10.1922/EJPRD_2503Ferreira14","DOIUrl":"10.1922/EJPRD_2503Ferreira14","url":null,"abstract":"<p><strong>Introduction: </strong>Pit and fissure sealants are effective in preventing caries disease, however, they may present flaws that damage the physical barrier leading to treatment failure.</p><p><strong>Objective: </strong>To answer the question ''Do pit and fissure sealants present good adhering to the dental structure when analyzed by their resistance to shear/microshear?\".</p><p><strong>Methods: </strong>This systematic review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) and was recorded in Open Science Framework. Embase, PubMed, SCOPUS, and Web of Science databases were used for the search strategy. The articles were selected according to the eligibility criteria. The risk of bias was performed with the adaptation of the quasi-experimental studies tool by Joanna Briggs Institute (JBI).</p><p><strong>Results: </strong>1245 studies were found in the databases when applying the search strategy, after removal of duplicates 881 were evaluated and 44 were selected. After applying the JBI tool, 30 studies presented low risk and 15 moderate risk of bias. Meta-analysis was not possible to performed due to the heterogeneity of the studies.</p><p><strong>Conclusion: </strong>The adhesion is dependent on the application protocol, and among the protocols evaluated, conditioning with 37% phosphoric acid for 60 seconds and contamination of the substrate, as these can affect sealant adhesion.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10291856","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
European Journal of Prosthodontics and Restorative Dentistry
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1