首页 > 最新文献

International Journal of Prosthodontics最新文献

英文 中文
Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting. 全弓种植体数字扫描的准确性:扫描方案、种植体数量和扫描体夹板的影响。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7332
Thomas Denneulin, Christophe Rignon-Bret, Guy Ravalec, Laurent Tapie, Denis Bouter, Claudine Wulfman

Purpose: To determine the effect of scanning protocol, number of implants, and implant splinting on the accuracy of digital scanning in the edentulous arch.

Materials and methods: A resin-based model of an edentulous mandible with six implants was scanned with a coordinate measurement machine as a reference and then with two intraoral scanner (IOS) systems (Trios 3 and Primescan). Ten scans were taken per IOS for three experiments, and each scan was compared to the reference data to evaluate trueness and precision. Analysis involved measurement of linear and angular discrepanices using engineering software. In experiment 1, three scanning protocols were compared (curvilinear, zigzag, and half-arch). In experiment 2, three clinical situations were simulated (6 implants, 4 implants-short arch, and 4 implants-long arch). In experiment 3, the effect of implant splinting with a suture thread was measured. Normal distribution of data was examined with Shapiro-Wilk test. Levene test was used for equality of variance (α = .05). Statistical differences in distance and angular deviations were analyzed using Student t test or ANOVA with post hoc Tukey test (α = .05).

Results: The best results in terms of trueness and precision were obtained with a linear scanning protocol and six implants. The results were as follows: Trios 3: trueness = 52 μm/0.42 degrees, precision = 40 μm/0.26 degrees; Primescan: trueness = 24 μm/0.28 degrees, precision = 18 μm/0.27 degrees. The scanning protocol did not significantly affect distance or angular deviation accuracy. Trueness and precision significantly decreased with four implants using Primescan and TRIOS 3. Splinting implants negatively affected accuracy with both IOS devices.

Conclusion: Both IOS devices achieved clinically satisfying accuracy for distance (< 100 μm) and angular (< 0.5 degrees) deviations with six implants and a linear scanning protocol. With four implants, angular deviations sometimes differed between implants within the same group depending on the IOS and the clinical situation. Int J Prosthodont 2023;36:219-227. doi: 10.11607/ijp.7332.

目的:探讨扫描方案、种植体数量和种植体夹板对无牙弓数字扫描精度的影响。材料与方法:先用三坐标测量仪作为参考,再用Trios 3和Primescan两套口内扫描仪(IOS)对6个种植体的无牙下颌树脂模型进行扫描。3次实验中,每个IOS进行10次扫描,并将每次扫描与参考数据进行比较,以评估真实度和精度。分析涉及使用工程软件测量线性和角度差异。实验1比较了三种扫描方案(曲线、之字形和半拱形)。实验2模拟3种临床情况(6个种植体,4个种植体-短弓,4个种植体-长弓)。在实验3中,我们测量了用缝线夹板固定种植体的效果。采用Shapiro-Wilk检验检验数据的正态分布。方差相等性采用Levene检验(α = 0.05)。距离和角度偏差的统计差异采用学生t检验或方差分析加事后Tukey检验(α = 0.05)。结果:采用线性扫描方案和6个种植体获得了最佳的准确性和准确性。结果表明:Trios 3:真实度= 52 μm/0.42度,精度= 40 μm/0.26度;Primescan:真实度= 24 μm/0.28度,精度= 18 μm/0.27度。扫描方案没有显著影响距离或角偏差精度。使用Primescan和TRIOS 3的四种种植体的准确性和准确性显着降低。夹板植入物对两种IOS设备的准确性都有负面影响。结论:两种IOS设备在6个植入物和线性扫描方案下,均获得了临床满意的距离(< 100 μm)和角度(< 0.5度)偏差精度。使用四个种植体时,同一组内种植体的角度偏差有时会因IOS和临床情况而异。[J]中华口腔医学杂志[J]; 2009; 31(6): 319 - 322。doi: 10.11607 / ijp.7332。
{"title":"Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting.","authors":"Thomas Denneulin,&nbsp;Christophe Rignon-Bret,&nbsp;Guy Ravalec,&nbsp;Laurent Tapie,&nbsp;Denis Bouter,&nbsp;Claudine Wulfman","doi":"10.11607/ijp.7332","DOIUrl":"https://doi.org/10.11607/ijp.7332","url":null,"abstract":"<p><strong>Purpose: </strong>To determine the effect of scanning protocol, number of implants, and implant splinting on the accuracy of digital scanning in the edentulous arch.</p><p><strong>Materials and methods: </strong>A resin-based model of an edentulous mandible with six implants was scanned with a coordinate measurement machine as a reference and then with two intraoral scanner (IOS) systems (Trios 3 and Primescan). Ten scans were taken per IOS for three experiments, and each scan was compared to the reference data to evaluate trueness and precision. Analysis involved measurement of linear and angular discrepanices using engineering software. In experiment 1, three scanning protocols were compared (curvilinear, zigzag, and half-arch). In experiment 2, three clinical situations were simulated (6 implants, 4 implants-short arch, and 4 implants-long arch). In experiment 3, the effect of implant splinting with a suture thread was measured. Normal distribution of data was examined with Shapiro-Wilk test. Levene test was used for equality of variance (α = .05). Statistical differences in distance and angular deviations were analyzed using Student <i>t</i> test or ANOVA with post hoc Tukey test (α = .05).</p><p><strong>Results: </strong>The best results in terms of trueness and precision were obtained with a linear scanning protocol and six implants. The results were as follows: Trios 3: trueness = 52 μm/0.42 degrees, precision = 40 μm/0.26 degrees; Primescan: trueness = 24 μm/0.28 degrees, precision = 18 μm/0.27 degrees. The scanning protocol did not significantly affect distance or angular deviation accuracy. Trueness and precision significantly decreased with four implants using Primescan and TRIOS 3. Splinting implants negatively affected accuracy with both IOS devices.</p><p><strong>Conclusion: </strong>Both IOS devices achieved clinically satisfying accuracy for distance (< 100 μm) and angular (< 0.5 degrees) deviations with six implants and a linear scanning protocol. With four implants, angular deviations sometimes differed between implants within the same group depending on the IOS and the clinical situation. Int J Prosthodont 2023;36:219-227. doi: 10.11607/ijp.7332.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9523584","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study. 天然牙釉质拮抗剂对釉面整体氧化锆冠和抛光整体氧化锆冠磨损的体内比较研究。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7798
Jay Rahesh Dondani, Vikrant Pardeshi, Arti Gangurde, Almas Shaikh, Aushili Mahule, Prachi Deval

Purpose: To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.

Materials and methods: Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.

Results: No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.

Conclusion: Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.

目的:比较6个月和12个月天然牙釉质对釉面全覆盖氧化锆冠和抛光氧化锆冠的磨损程度。材料与方法:30名年龄在18 ~ 35岁之间的受试者参与本研究。受试者共获得60个单牙冠,分为两组:(1)30个釉面整体氧化锆牙冠,与天然牙釉质相对立(a组);(2) 30个抛光的整体氧化锆冠(B组)。每名受试者均获得两组的冠,放置在经根管治疗的上颌或下颌第一磨牙上。在24小时、6个月和12个月时对牙弓进行印模。用3D光学扫描仪对铸件进行扫描。使用3D AutoCAD软件将召回扫描叠加并与基线扫描进行比较。另设对照组,比较天然牙釉质与天然牙釉质的磨损值。结果:A组(42.80 μm)与B组(42.50 μm)使用6个月后牙釉质磨损无显著性差异(P = 0.855)。使用12个月后,a组牙釉质磨损度为81.87 μm, B组牙釉质磨损度为71.43 μm,差异有统计学意义(P < 0.05)。结论:在临床使用12个月后,釉面整体氧化锆冠对牙釉质的磨损大于抛光整体氧化锆冠对牙釉质的磨损。
{"title":"Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study.","authors":"Jay Rahesh Dondani,&nbsp;Vikrant Pardeshi,&nbsp;Arti Gangurde,&nbsp;Almas Shaikh,&nbsp;Aushili Mahule,&nbsp;Prachi Deval","doi":"10.11607/ijp.7798","DOIUrl":"https://doi.org/10.11607/ijp.7798","url":null,"abstract":"<p><strong>Purpose: </strong>To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.</p><p><strong>Materials and methods: </strong>Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.</p><p><strong>Results: </strong>No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.</p><p><strong>Conclusion: </strong>Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9735006","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Finite Element Analysis of Endocrown and Post-and-Core Abutments for Removable Partial Dentures with Different Framework Materials. 不同框架材料可摘局部义齿内冠与桩核基台的有限元分析。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7269
Gokce Soganci Unsal, Selen Ince Yusufoglu

Purpose: To evaluate the stress distribution in endocrowns and post-and-core crowns used as abutments for a Kennedy Class I removable partial denture constructed with different framework materials.

Materials and methods: 3D models of a Kennedy Class I mandible were constructed. Cobalt-chromium (Co-Cr) and polyether ether ketone (PEEK) frameworks were simulated for Models 1 and 2, respectively. An endocrown and a fiber post-and-core crown for the mandibular left and right second premolar abutments, respectively, were simulated for both models. Lithium disilicate porcelain was defined for the crowns. A 200-N occlusal force was applied in the vertical and 30-degree oblique directions.

Results: The von Mises stresses were evaluated for the abutments and prostheses, and the principal stresses for the cortical bone under vertical and oblique loading. Endocrowns showed lower stress values than post-and-core crowns in both models. Post-and-core crowns generated the highest stress in Model 2 under vertical loading. The PEEK framework caused higher stress values on the abutments than Co-Cr. Compressive stresses were higher than tensile stresses in cortical bone. The highest compressive stress was observed around the left premolar cortical bone area in Model 1 under oblique loading. Oblique loading caused lower stress values than vertical loading, except for on the minor connectors and cortical bone.

Conclusion: From a biomechanical perspective, endocrowns may be more advantageous than post-and-core crowns when used as abutments for a Kennedy Class I removable partial denture. In addition, Co-Cr frameworks showed more favorable stress distribution on abutments than PEEK frameworks. Int J Prosthodont 2023;36:203-215. doi: 10.11607/ijp.7269.

目的:评价不同框架材料制备的Kennedy I类可摘局部义齿内冠和桩核冠作为基台的应力分布。材料与方法:建立Kennedy I级下颌骨的三维模型。模型1和模型2分别模拟了钴铬(Co-Cr)和聚醚醚酮(PEEK)框架。在两种模型中分别模拟下颌左、右第二前磨牙基牙的内冠和纤维桩核冠。冠用二硅酸锂瓷。在垂直方向和30度斜向方向施加200-N的咬合力。结果:评估了基牙和假体的von Mises应力,以及皮质骨在垂直和斜向载荷下的主应力。在两种模型中,内冠的应力值均低于桩核冠。竖向荷载作用下,模型2中桩核冠产生的应力最大。PEEK框架在基台上的应力值高于Co-Cr框架。皮质骨的压应力高于拉应力。斜向加载下,模型1左前磨牙皮质骨区周围的压应力最大。除了在较小的连接物和皮质骨上,斜向加载比垂直加载产生更低的应力值。结论:从生物力学的角度来看,内冠比桩核冠更适合作为Kennedy I类可摘局部义齿的基牙。此外,Co-Cr框架在基台上的应力分布优于PEEK框架。[J]中华口腔医学杂志[J]; 2009; 31(6): 393 - 398。doi: 10.11607 / ijp.7269。
{"title":"Finite Element Analysis of Endocrown and Post-and-Core Abutments for Removable Partial Dentures with Different Framework Materials.","authors":"Gokce Soganci Unsal,&nbsp;Selen Ince Yusufoglu","doi":"10.11607/ijp.7269","DOIUrl":"https://doi.org/10.11607/ijp.7269","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the stress distribution in endocrowns and post-and-core crowns used as abutments for a Kennedy Class I removable partial denture constructed with different framework materials.</p><p><strong>Materials and methods: </strong>3D models of a Kennedy Class I mandible were constructed. Cobalt-chromium (Co-Cr) and polyether ether ketone (PEEK) frameworks were simulated for Models 1 and 2, respectively. An endocrown and a fiber post-and-core crown for the mandibular left and right second premolar abutments, respectively, were simulated for both models. Lithium disilicate porcelain was defined for the crowns. A 200-N occlusal force was applied in the vertical and 30-degree oblique directions.</p><p><strong>Results: </strong>The von Mises stresses were evaluated for the abutments and prostheses, and the principal stresses for the cortical bone under vertical and oblique loading. Endocrowns showed lower stress values than post-and-core crowns in both models. Post-and-core crowns generated the highest stress in Model 2 under vertical loading. The PEEK framework caused higher stress values on the abutments than Co-Cr. Compressive stresses were higher than tensile stresses in cortical bone. The highest compressive stress was observed around the left premolar cortical bone area in Model 1 under oblique loading. Oblique loading caused lower stress values than vertical loading, except for on the minor connectors and cortical bone.</p><p><strong>Conclusion: </strong>From a biomechanical perspective, endocrowns may be more advantageous than post-and-core crowns when used as abutments for a Kennedy Class I removable partial denture. In addition, Co-Cr frameworks showed more favorable stress distribution on abutments than PEEK frameworks. Int J Prosthodont 2023;36:203-215. doi: 10.11607/ijp.7269.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9519693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Crown Material and Occlusal Thickness Affect the Load Stress Dissipation on 3D Molar Crowns: Finite Element Analysis 牙冠材料和咬合厚度对三维磨牙冠载荷应力耗散的影响:有限元分析
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.6974
Leando de Moura Martins, Liliane Motta de Lima, Luciana Mendonça da Silva, Flávia Cohen-Carneiro, Pedro Yoshito Noritomi, Fabio Cesar Lorenzoni

Purpose: To compare the mechanical behavior (stress load dissipation and/or concentration) of posterior crowns made from Lava Ultimate (LU; 3M ESPE) and IPS e.max CAD (LD; Ivoclar Vivadent) using finite element analysis (FEA).

Materials and methods: A 3D model of a mandibular first molar was prepared by reducing the occlusal surface by 1 or 2 mm (according to group), the axial walls by 1.5 mm, and using a 0.8-mm-deep shoulder margin as a finish line. A convergence of 6 degrees between opposing walls was set. Subsequently, four 3D crown models were created according to two test groups with two different occlusal thicknesses: (1) LD with 1.0 mm (LD1); (2) LD with 2.0 mm (LD2); (3) LU with 1.0 mm (LU1); and (4) LU with 2.0 mm (LU2). FEA models were constructed using the software Femap (Siemens). A load of 200 N was applied in the axial and oblique (20 degrees) directions for each group, and stress dissipation was viewed using the NEi Nastran software.

Results: FEA results demonstrated that the LU crowns dissipated the occlusal load to the tooth structure, whereas the LD material concentrated the load inside the crowns. For the LU material, the lower the occlusal thickness, the higher the stress concentration inside the crown became, and the 2.0-mm occlusal thickness transferred lower stress to the tooth structure. The oblique, rather than the vertical, load caused an increase in the maximum stress concentration at the shoulder margin and axial walls.

Conclusion: The higher the Young's Modulus mismatch between the crown material and substrate, the higher the load stress concentration inside the material became. The 2-mm occlusal thickness acted by decreasing the load stress to the tooth substrate. Finally, the axial load delivered more favorable stress transmission to the tooth substrate. The crown material and the occlusal thickness appear to be two factors that affect the mechanical behavior of stress dissipation to the tooth structure.

目的:比较Lava Ultimate (LU)材料后牙冠的力学性能(应力荷载消散和/或集中);3M ESPE)和IPS e.max CAD (LD);采用有限元分析(FEA)。材料与方法:将下颌第一磨牙的咬合面按组缩小1 ~ 2mm,轴向壁缩小1.5 mm,以0.8 mm深的肩缘为终点线,制作三维模型。在相对的墙壁之间设置了6度的收敛。随后,根据两种不同咬合厚度的两组,制作4个三维冠模型:(1)LD为1.0 mm (LD1);(2) LD为2.0 mm (LD2);(3) LU 1.0 mm (LU1);(4) LU为2.0 mm (LU2)。采用西门子Femap软件建立有限元模型。每组分别在轴向和斜向(20度)方向施加200 N的荷载,使用NEi Nastran软件观察应力消散情况。结果:有限元分析结果表明,LU冠将牙合负荷分散到牙齿结构上,而LD材料将牙合负荷集中在牙冠内部。对于LU材料,咬合厚度越小,冠内应力集中越大,2.0 mm的咬合厚度传递给牙体结构的应力越小。斜荷载导致肩缘和轴壁的最大应力集中增加,而不是垂直荷载。结论:冠材料与基体的杨氏模量失配越大,材料内部的载荷应力集中越大。2mm的咬合厚度降低了对牙基的载荷应力。最后,轴向载荷为齿基提供了更有利的应力传递。牙冠材料和咬合厚度是影响牙结构应力消散力学行为的两个因素。
{"title":"Crown Material and Occlusal Thickness Affect the Load Stress Dissipation on 3D Molar Crowns: Finite Element Analysis","authors":"Leando de Moura Martins,&nbsp;Liliane Motta de Lima,&nbsp;Luciana Mendonça da Silva,&nbsp;Flávia Cohen-Carneiro,&nbsp;Pedro Yoshito Noritomi,&nbsp;Fabio Cesar Lorenzoni","doi":"10.11607/ijp.6974","DOIUrl":"https://doi.org/10.11607/ijp.6974","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the mechanical behavior (stress load dissipation and/or concentration) of posterior crowns made from Lava Ultimate (LU; 3M ESPE) and IPS e.max CAD (LD; Ivoclar Vivadent) using finite element analysis (FEA).</p><p><strong>Materials and methods: </strong>A 3D model of a mandibular first molar was prepared by reducing the occlusal surface by 1 or 2 mm (according to group), the axial walls by 1.5 mm, and using a 0.8-mm-deep shoulder margin as a finish line. A convergence of 6 degrees between opposing walls was set. Subsequently, four 3D crown models were created according to two test groups with two different occlusal thicknesses: (1) LD with 1.0 mm (LD1); (2) LD with 2.0 mm (LD2); (3) LU with 1.0 mm (LU1); and (4) LU with 2.0 mm (LU2). FEA models were constructed using the software Femap (Siemens). A load of 200 N was applied in the axial and oblique (20 degrees) directions for each group, and stress dissipation was viewed using the NEi Nastran software.</p><p><strong>Results: </strong>FEA results demonstrated that the LU crowns dissipated the occlusal load to the tooth structure, whereas the LD material concentrated the load inside the crowns. For the LU material, the lower the occlusal thickness, the higher the stress concentration inside the crown became, and the 2.0-mm occlusal thickness transferred lower stress to the tooth structure. The oblique, rather than the vertical, load caused an increase in the maximum stress concentration at the shoulder margin and axial walls.</p><p><strong>Conclusion: </strong>The higher the Young's Modulus mismatch between the crown material and substrate, the higher the load stress concentration inside the material became. The 2-mm occlusal thickness acted by decreasing the load stress to the tooth substrate. Finally, the axial load delivered more favorable stress transmission to the tooth substrate. The crown material and the occlusal thickness appear to be two factors that affect the mechanical behavior of stress dissipation to the tooth structure.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10089021","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical and Microbiologic Outcomes of Ceramic Laminate Veneers Bonded to Teeth Without a Finish Line: 1-year Results of a Prospective Study. 无终点线的陶瓷贴面的临床和微生物结果:1年的前瞻性研究结果。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7718
Danila de Oliveira, Fernando I Souza, Mariana T Caixeta, Cristiane Duque, Sandra H P Oliveira, Eduardo P Rocha

Purpose: To evaluate changes in the periodontium of teeth restored with ultrathin (0.2 to 0.39 mm) ceramic laminate veneers (CLVs) placed subgingivally without a finish line compared to the same teeth before restorative treatment and to nonrestored antagonist teeth in healthy periodontium patients. Materials and Methods: A total of 73 CLVs were bonded onto the enamel surface of teeth without a finish line and with the cervical margin placed about 0.5 mm subgingivally. The gingival crevicular fluid was collected before bonding (baseline) and at 7, 180, and 365 days after bonding to quantify S mitis, P intermedia, and P gingivalis by quantitative polymerase chain reaction analysis. Visible plaque index (VPI), bleeding on probing (BOP), probing depth (PD), clinical attachment loss (CAL), gingival recession (GR), and marginal adaptation were evaluated from baseline to 365 days in both groups. Results: No statistically significant differences were observed in VPI, PD, or BOP at any time point in the intragroup or intergroup comparisons (P > .05). All restorations obtained the alpha concept for marginal adaptation (ie, the restoration margin remained ideal at all time points). There was a statistically significant difference for S mitis between 180 and 365 days (P = .03). No statistically significant difference was observed for P gingivalis at any time point (P > .05). Conclusion: The periodontium in the restored group showed a clinical behavior similar to baseline. Overcontouring of the ultrathin (up to 0.39 mm) CLV, similar to the cementoenamel junction convexity, did not contribute to plaque accumulation or changes in the oral microbiota of patients with a healthy periodontium and proper oral hygiene instruction.

目的:评价超薄(0.2 ~ 0.39 mm)陶瓷贴面(CLVs)在龈下无终点线修复的牙齿与修复前的牙齿和未修复的健康牙周患者的牙齿相比,牙周组织的变化。材料与方法:将73个clv无终点地粘接在牙釉质表面,将颈缘置于龈下约0.5 mm处。在粘接前(基线)和粘接后7、180和365天采集龈沟液,通过定量聚合酶链式反应分析定量S - mitis、P - intermedimedium和P - gingivalis。从基线到365天,对两组的可见菌斑指数(VPI)、探诊出血(BOP)、探诊深度(PD)、临床附着丧失(CAL)、牙龈退缩(GR)和边缘适应进行评估。结果:组内、组间各时间点VPI、PD、BOP比较差异均无统计学意义(P > 0.05)。所有恢复都获得了边际适应的alpha概念(即恢复边缘在所有时间点都保持理想状态)。180天和365天S型炎的发生率差异有统计学意义(P = 0.03)。各时间点P龈值比较差异均无统计学意义(P > 0.05)。结论:修复组牙周组织临床表现与基线相近。超薄CLV(高达0.39 mm)的轮廓与牙骨质-牙釉质交界处的凸度相似,对于具有健康牙周组织和适当口腔卫生指导的患者,不会导致牙菌斑积累或口腔微生物群的变化。
{"title":"Clinical and Microbiologic Outcomes of Ceramic Laminate Veneers Bonded to Teeth Without a Finish Line: 1-year Results of a Prospective Study.","authors":"Danila de Oliveira,&nbsp;Fernando I Souza,&nbsp;Mariana T Caixeta,&nbsp;Cristiane Duque,&nbsp;Sandra H P Oliveira,&nbsp;Eduardo P Rocha","doi":"10.11607/ijp.7718","DOIUrl":"https://doi.org/10.11607/ijp.7718","url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate changes in the periodontium of teeth restored with ultrathin (0.2 to 0.39 mm) ceramic laminate veneers (CLVs) placed subgingivally without a finish line compared to the same teeth before restorative treatment and to nonrestored antagonist teeth in healthy periodontium patients. <b>Materials and Methods:</b> A total of 73 CLVs were bonded onto the enamel surface of teeth without a finish line and with the cervical margin placed about 0.5 mm subgingivally. The gingival crevicular fluid was collected before bonding (baseline) and at 7, 180, and 365 days after bonding to quantify <i>S mitis, P intermedia,</i> and <i>P gingivalis</i> by quantitative polymerase chain reaction analysis. Visible plaque index (VPI), bleeding on probing (BOP), probing depth (PD), clinical attachment loss (CAL), gingival recession (GR), and marginal adaptation were evaluated from baseline to 365 days in both groups. <b>Results:</b> No statistically significant differences were observed in VPI, PD, or BOP at any time point in the intragroup or intergroup comparisons (<i>P</i> > .05). All restorations obtained the alpha concept for marginal adaptation (ie, the restoration margin remained ideal at all time points). There was a statistically significant difference for S mitis between 180 and 365 days (<i>P</i> = .03). No statistically significant difference was observed for P gingivalis at any time point (<i>P</i> > .05). <b>Conclusion:</b> The periodontium in the restored group showed a clinical behavior similar to baseline. Overcontouring of the ultrathin (up to 0.39 mm) CLV, similar to the cementoenamel junction convexity, did not contribute to plaque accumulation or changes in the oral microbiota of patients with a healthy periodontium and proper oral hygiene instruction.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10096917","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Trueness of the Combined Intra- and Extraoral Scanning Technique for Transferring Subgingival Contours from Provisional Restorations to Definitive Restorations 口腔内外联合扫描技术将龈下轮廓从临时修复体转移到最终修复体的真实性
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7030
Koma Sanda, Noriyuki Yasunami, Yasuyuki Matsushita, Akihiro Furuhashi, Tatsuya Matsuzaki, Mikio Imai, Chi-Hsiang Cheng, Kiyoshi Koyano

Purpose: To compare the morphologic trueness of provisional and definitive restorations constructed with conventional custom impression techniques to those constructed with intra- and extraoral scanning (IEOS), which can digitally transfer the subgingival morphology of the provisional restoration to the definitive restoration.

Materials and methods: Provisional restorations were fabricated on typodonts in which implants were placed. In the conventional method, a customized impression coping was produced by using polymethyl methacrylate resin to transfer the subgingival contour of the provisional restoration. Impressions were taken with silicone impression material, and definitive restorations were made by CAM. The IEOS technique was performed as previously reported. In brief, three individually scanned stereolithography (STL) files were superimposed in CAD software to transfer the morphology of the provisional restoration to the definitive restoration. Definitive restorations were then made by CAM. The provisional and definitive restorations were both scanned by IOS. Scanned data files were superimposed with morphometry software, and the distortions were measured. Student t test was used for statistical analysis.

Results: The subgingival morphologies of definitive restorations prepared by the conventional method showed significant negative distortions compared to definitive restorations prepared by the IEOS technique.

Conclusion: The IEOS technique can more accurately transfer the subgingival contour of provisional restorations to definitive restorations compared to the conventional customized impression coping technique.

目的:比较传统自定义印模技术与口内、口外扫描(IEOS)技术构建的临时修复体和最终修复体的形态真实性,IEOS技术可以将临时修复体的龈下形态数字化转移到最终修复体。材料和方法:将临时修复体制作在假体上。在传统方法中,使用聚甲基丙烯酸甲酯树脂制作定制的印模顶,以转移临时修复的龈下轮廓。用硅胶印模材料进行印模,并由CAM进行最终修复。IEOS技术按照之前的报道进行。简而言之,三个单独扫描的立体光刻(STL)文件在CAD软件中叠加,以将临时修复的形态学转移到最终修复。然后由CAM进行了最终修复。临时修复体和最终修复体均采用IOS扫描。扫描数据文件与形态测量软件叠加,并测量畸变。采用学生t检验进行统计分析。结果:与IEOS技术制备的最终修复体相比,常规方法制备的最终修复体龈下形态呈现明显的负扭曲。结论:IEOS技术比传统的定制印模处理技术更能准确地将临时修复体的龈下轮廓转移到确定修复体。
{"title":"Trueness of the Combined Intra- and Extraoral Scanning Technique for Transferring Subgingival Contours from Provisional Restorations to Definitive Restorations","authors":"Koma Sanda,&nbsp;Noriyuki Yasunami,&nbsp;Yasuyuki Matsushita,&nbsp;Akihiro Furuhashi,&nbsp;Tatsuya Matsuzaki,&nbsp;Mikio Imai,&nbsp;Chi-Hsiang Cheng,&nbsp;Kiyoshi Koyano","doi":"10.11607/ijp.7030","DOIUrl":"https://doi.org/10.11607/ijp.7030","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the morphologic trueness of provisional and definitive restorations constructed with conventional custom impression techniques to those constructed with intra- and extraoral scanning (IEOS), which can digitally transfer the subgingival morphology of the provisional restoration to the definitive restoration.</p><p><strong>Materials and methods: </strong>Provisional restorations were fabricated on typodonts in which implants were placed. In the conventional method, a customized impression coping was produced by using polymethyl methacrylate resin to transfer the subgingival contour of the provisional restoration. Impressions were taken with silicone impression material, and definitive restorations were made by CAM. The IEOS technique was performed as previously reported. In brief, three individually scanned stereolithography (STL) files were superimposed in CAD software to transfer the morphology of the provisional restoration to the definitive restoration. Definitive restorations were then made by CAM. The provisional and definitive restorations were both scanned by IOS. Scanned data files were superimposed with morphometry software, and the distortions were measured. Student t test was used for statistical analysis.</p><p><strong>Results: </strong>The subgingival morphologies of definitive restorations prepared by the conventional method showed significant negative distortions compared to definitive restorations prepared by the IEOS technique.</p><p><strong>Conclusion: </strong>The IEOS technique can more accurately transfer the subgingival contour of provisional restorations to definitive restorations compared to the conventional customized impression coping technique.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9787344","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Is There "A Best" Centric Relation Record? Centric Relation Records, Condyle Positions, and Their Practical Significance. 以“最佳”为中心的关系记录存在吗?中心关系记录、髁突位置及其现实意义。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7786
Karl-Heinz Utz, Walter Lückerath, Peter Schwarting, Wolfgang Noethlichs, Ralph Büttner, Manfred Grüner, Edgar Fuß, Helmut Stark

Purpose: To investigate if and how the positions of condyles in centric relation (CR) varied from each other using different CR records.

Materials and methods: Condylar positions in CR were repeatedly recorded by four licensed clinicians in 81 stomatognathically healthy, fully dentate subjects with six different types of CR records. The maxillary casts were mounted in articulators after individual facebow transfer, and the mandibular casts were mounted with a central bearing point (CBP) registration on the tip of the Gothic arch. Mean values from three registrations of the centric condylar positions with each of the six methods were calculated, and comparative calculations were made.

Results: The median spatial distances of the condylar positions between the CBP and all other CR records was 0.73 ± 0.24 mm (0 to 3.19 mm). The median spatial values between the condylar positions of the different CR records ranged from 0.48 to 0.79 mm. Statistically, the positions of almost all types of registration were slightly different from each other.

Conclusion: Different CR records reproduce slightly different positions of the mandible, which is especially true for CBP registration, whereas reproducibilities and SDs between registrations are similar. Unrefined wax-wafer registrations using bimanual manipulation have proven particularly successful with regard to precision and time requirements, as has CBP registration with regard to condylar position.

目的:探讨不同的髁突中心关系(CR)记录中髁突位置的变化情况。材料和方法:对81名口腔健康、牙齿发育完整的受试者进行6种不同类型的CR记录,由4名有执照的临床医生反复记录CR时的髁突位置。上颌模型在单独脸弓转移后安装在关节器中,下颌骨模型安装在哥特式拱门顶端的中心支承点(CBP)注册。计算了六种方法三次配准的均值,并进行了比较计算。结果:髁突位置与CBP与其他CR记录之间的中位空间距离为0.73±0.24 mm (0 ~ 3.19 mm)。不同CR记录髁突位置间的空间中位数为0.48 ~ 0.79 mm。统计上,几乎所有类型的注册位置都略有不同。结论:不同的CR记录再现的下颌骨位置略有不同,特别是CBP登记,而登记之间的重现性和SDs相似。在精度和时间要求方面,使用双手操作的未精制蜡晶片配准已被证明特别成功,就髁位置而言,CBP配准也是如此。
{"title":"Is There \"A Best\" Centric Relation Record? Centric Relation Records, Condyle Positions, and Their Practical Significance.","authors":"Karl-Heinz Utz,&nbsp;Walter Lückerath,&nbsp;Peter Schwarting,&nbsp;Wolfgang Noethlichs,&nbsp;Ralph Büttner,&nbsp;Manfred Grüner,&nbsp;Edgar Fuß,&nbsp;Helmut Stark","doi":"10.11607/ijp.7786","DOIUrl":"https://doi.org/10.11607/ijp.7786","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate if and how the positions of condyles in centric relation (CR) varied from each other using different CR records.</p><p><strong>Materials and methods: </strong>Condylar positions in CR were repeatedly recorded by four licensed clinicians in 81 stomatognathically healthy, fully dentate subjects with six different types of CR records. The maxillary casts were mounted in articulators after individual facebow transfer, and the mandibular casts were mounted with a central bearing point (CBP) registration on the tip of the Gothic arch. Mean values from three registrations of the centric condylar positions with each of the six methods were calculated, and comparative calculations were made.</p><p><strong>Results: </strong>The median spatial distances of the condylar positions between the CBP and all other CR records was 0.73 ± 0.24 mm (0 to 3.19 mm). The median spatial values between the condylar positions of the different CR records ranged from 0.48 to 0.79 mm. Statistically, the positions of almost all types of registration were slightly different from each other.</p><p><strong>Conclusion: </strong>Different CR records reproduce slightly different positions of the mandible, which is especially true for CBP registration, whereas reproducibilities and SDs between registrations are similar. Unrefined wax-wafer registrations using bimanual manipulation have proven particularly successful with regard to precision and time requirements, as has CBP registration with regard to condylar position.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9732431","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Self-Assessment of Hungarian Dentists Regarding Removable Partial Denture Design and Communication with the Dental Technician. 匈牙利牙医关于可移动局部义齿设计和与牙科技术员沟通的自我评估。
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7523
Gyula Marada, Zoltán Baráth, Tamás Tarjányi, Márta Radnai

Purpose: To evaluate the extent to which dentists elaborate removable partial denture (RPD) design themselves and what they leave to the dental laboratory, as well as to assess the quality of information transferred to the technicians.

Materials and methods: Data were collected using a questionnaire, and the responses of 211 dentists were analyzed. The categorized variables were analyzed using chi-square test and Fisher exact test. The significance level was considered as the standard P < .05.

Results: More than half (59.0%) of the dentists reported making an accurate, clear design for the dental technician before fabrication of the metal-framework RPD; 191 dentists (91.0%) specified the abutment teeth, 70.8% chose the type of clasps, and 60.7% gave instructions for the major connectors. The respondents largely took into account periodontal hygiene considerations (82.4%), and about one-third (37.7%) reported they were sending clear, precise instructions to the lab. The denture design was sent to the technician mainly (65.0%) in both drawing and text form. About half of the dentists (55.6%) gave only guidelines and left more details to be defined by the dental technician. Most dentists took responsibility in case of esthetic problems, irrespective of whether the dentist or technician prepared the denture design.

Conclusion: Everyday practice concerning RPD design is far from the professional, legal, and ethical guidelines and rules relating to the duties and responsibilities of the dentist in relation to RPD design, and the situation therefore needs to be improved. Int J Prosthodont 2022;36:131-137. doi: 10.11607/ijp.7523.

目的:评估牙科医生自行设计可摘局部义齿(RPD)的程度以及他们留给牙科实验室的内容,并评估传递给技术人员的信息质量。材料与方法:采用问卷调查法收集资料,对211名牙科医生的反馈进行分析。分类变量分析采用卡方检验和Fisher精确检验。以显著性水平P < 0.05为标准。结果:超过一半(59.0%)的牙医报告在制作金属框架RPD前为牙科技师做了准确、清晰的设计;191名牙医(91.0%)指明了基牙,70.8%的人选择了卡环的类型,60.7%的人指明了主要的接插件。受访者主要考虑牙周卫生因素(82.4%),约三分之一(37.7%)的受访者报告他们向实验室发送了清晰、准确的指示。义齿设计主要以图纸和文字两种形式发送给技术人员(65.0%)。约一半的牙医(55.6%)只提供指引,而把更多细节留给牙科技师。大多数牙医都承担了美观问题的责任,无论是否牙医或技术人员准备了假牙的设计。结论:在RPD设计的日常实践中,与牙医在RPD设计中职责相关的专业、法律和道德准则和规则相距甚远,需要改进。[J]中华口腔医学杂志;2009;31(6):391 - 391。doi: 10.11607 / ijp.7523。
{"title":"Self-Assessment of Hungarian Dentists Regarding Removable Partial Denture Design and Communication with the Dental Technician.","authors":"Gyula Marada,&nbsp;Zoltán Baráth,&nbsp;Tamás Tarjányi,&nbsp;Márta Radnai","doi":"10.11607/ijp.7523","DOIUrl":"https://doi.org/10.11607/ijp.7523","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the extent to which dentists elaborate removable partial denture (RPD) design themselves and what they leave to the dental laboratory, as well as to assess the quality of information transferred to the technicians.</p><p><strong>Materials and methods: </strong>Data were collected using a questionnaire, and the responses of 211 dentists were analyzed. The categorized variables were analyzed using chi-square test and Fisher exact test. The significance level was considered as the standard <i>P</i> < .05.</p><p><strong>Results: </strong>More than half (59.0%) of the dentists reported making an accurate, clear design for the dental technician before fabrication of the metal-framework RPD; 191 dentists (91.0%) specified the abutment teeth, 70.8% chose the type of clasps, and 60.7% gave instructions for the major connectors. The respondents largely took into account periodontal hygiene considerations (82.4%), and about one-third (37.7%) reported they were sending clear, precise instructions to the lab. The denture design was sent to the technician mainly (65.0%) in both drawing and text form. About half of the dentists (55.6%) gave only guidelines and left more details to be defined by the dental technician. Most dentists took responsibility in case of esthetic problems, irrespective of whether the dentist or technician prepared the denture design.</p><p><strong>Conclusion: </strong>Everyday practice concerning RPD design is far from the professional, legal, and ethical guidelines and rules relating to the duties and responsibilities of the dentist in relation to RPD design, and the situation therefore needs to be improved. Int J Prosthodont 2022;36:131-137. doi: 10.11607/ijp.7523.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9889701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluating the Feasibility and Accuracy of Digitizing a Maxillary Defect Model Simulating Various Trismus Conditions. 评估将模拟各种三错位情况的上颌骨缺损模型数字化的可行性和准确性。
IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Pub Date : 2023-05-01 Epub Date: 2022-12-09 DOI: 10.11607/ijp.7842
Yuan Gao, Mariko Hattori, Manjin Zhang, Mahmoud E Elbashti, Ralf-Joachim Kohal, Yuka I Sumita

Purpose: To compare the feasibility and accuracy of using intraoral scanners to digitize a maxillary defect model simulating various trismus conditions.

Materials and methods: Four intraoral scanners were used to digitize a maxillary defect model simulating four different degrees of trismus (mouth opening = 10, 20, 30, and 40 mm), and the scanned areas were compared. The scans were also superimposed on each other for precision analysis and on reference data for trueness analysis using 3D evaluation software. Two-way ANOVA was used to compare area, precision, and trueness among scanners and among conditions.

Results: The surface area for which 3D data were obtained by the intraoral scanners ranged from 2,672 to 6,613 mm2. Significant differences were observed between the scanners (P < .001) and between the trismus conditions (P < .001), with a smaller scanned surface area in severe trismus (10 mm). Trueness ranged from 0.033 to 0.301 mm, and precision from 0.022 to 0.397 mm. Significant differences in trueness and precision values were found among the scanners (P = .001 and P = .001, respectively), but not the trismus conditions (P = .260 and P = .075, respectively).

Conclusion: Although trueness and precision differed between intraoral scanners, digitization of the maxillectomy model simulating various trismus conditions appears to be feasible from the perspective of accuracy with all of the scanners used. The smaller scanned surface area in the severe trismus condition was due to lack of data on the defect site in that condition.

目的:比较使用口内扫描仪数字化模拟各种三错位情况的上颌骨缺损模型的可行性和准确性:使用四台口内扫描仪对模拟四种不同程度三错位(张口=10、20、30 和 40 毫米)的上颌缺损模型进行数字化,并对扫描区域进行比较。扫描结果还相互叠加,以进行精确度分析,并与参考数据叠加,使用 3D 评估软件进行真实性分析。使用双向方差分析比较不同扫描仪和不同条件下的扫描面积、精度和真实度:口内扫描仪获得三维数据的表面积从 2,672 到 6,613 平方毫米不等。不同扫描仪之间存在显著差异(P < .001),不同三度畸形之间也存在显著差异(P < .001),严重三度畸形的扫描表面积较小(10 毫米)。真实度范围为 0.033 至 0.301 毫米,精确度范围为 0.022 至 0.397 毫米。不同扫描仪的真实度和精确度值存在显著差异(分别为 P = .001 和 P = .001),但三视图条件下的真实度和精确度值无显著差异(分别为 P = .260 和 P = .075):结论:虽然不同口内扫描仪的真实度和精确度不同,但从精确度的角度来看,使用所有扫描仪对模拟各种三凹陷情况的上颌骨切除模型进行数字化似乎都是可行的。严重三错位情况下的扫描面积较小,这是因为缺乏该情况下缺损部位的数据。
{"title":"Evaluating the Feasibility and Accuracy of Digitizing a Maxillary Defect Model Simulating Various Trismus Conditions.","authors":"Yuan Gao, Mariko Hattori, Manjin Zhang, Mahmoud E Elbashti, Ralf-Joachim Kohal, Yuka I Sumita","doi":"10.11607/ijp.7842","DOIUrl":"10.11607/ijp.7842","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the feasibility and accuracy of using intraoral scanners to digitize a maxillary defect model simulating various trismus conditions.</p><p><strong>Materials and methods: </strong>Four intraoral scanners were used to digitize a maxillary defect model simulating four different degrees of trismus (mouth opening = 10, 20, 30, and 40 mm), and the scanned areas were compared. The scans were also superimposed on each other for precision analysis and on reference data for trueness analysis using 3D evaluation software. Two-way ANOVA was used to compare area, precision, and trueness among scanners and among conditions.</p><p><strong>Results: </strong>The surface area for which 3D data were obtained by the intraoral scanners ranged from 2,672 to 6,613 mm<sup>2</sup>. Significant differences were observed between the scanners (P < .001) and between the trismus conditions (P < .001), with a smaller scanned surface area in severe trismus (10 mm). Trueness ranged from 0.033 to 0.301 mm, and precision from 0.022 to 0.397 mm. Significant differences in trueness and precision values were found among the scanners (P = .001 and P = .001, respectively), but not the trismus conditions (P = .260 and P = .075, respectively).</p><p><strong>Conclusion: </strong>Although trueness and precision differed between intraoral scanners, digitization of the maxillectomy model simulating various trismus conditions appears to be feasible from the perspective of accuracy with all of the scanners used. The smaller scanned surface area in the severe trismus condition was due to lack of data on the defect site in that condition.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.1,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10091812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of Cement Type on its Quality of Removal from Zirconium Oxide Implant-Supported Restorations 水泥类型对氧化锆种植体修复体去除质量的影响
IF 2.3 4区 医学 Q2 Medicine Pub Date : 2023-05-01 DOI: 10.11607/ijp.7088
Egle Vindasiute-Narbute, Algirdas Puisys, Rolandas Andrijauskas, Gaivile Pileicikiene, Dominyka Malinauskaite, Tomas Linkevicius

Purpose: To assess excess cement removal after cementation of implant-supported cementretained restorations using different cements.

Materials and methods: A dental model with soft tissue imitation, 20 individual zirconium oxide abutments, and 20 zirconium oxide crowns were fabricated. Half of the restorations were cemented using resin cement (RX) and the other half with resin-modified glass-ionomer cement (GC). After cement cleaning, each crown-abutment unit was removed from the model, photographed, and analyzed from 4 surfaces, resulting in a final sample size of 80 measurements. Radiographic examination and the computerized planimetric method in Adobe Photoshop were used to determine the amount of the cement left and to evaluate the ratio between the area of cement residue and the whole crown-abutment surface. The significance was set to .05.

Results: GC resulted in 7.4% more cement residue on all surfaces (P < .05) than RX. The P value on three of the surfaces (all except mesial) was < .05, meaning that the data were statistically significantly different between groups and surfaces. Absolute removal of the cement was impossible in all cases (100%), and in 95% of the cases, cement remnants could not be detected radiographically.

Conclusion: More undetected cement remains when using resin-modified glass-ionomer cement. It was impossible to remove excess of both types of cements completely. Most of the cement remains on the distal surface. Radiographic examination could not be considered as a reliable method to identify excess cement.

目的:评估不同类型骨水泥对种植体支撑骨水泥修复体的骨水泥去除效果。材料与方法:制作1个软组织模拟牙模型、20个氧化锆基牙、20个氧化锆冠。一半的修复体使用树脂水泥(RX),另一半使用树脂改性玻璃离子水泥(GC)。水泥清洗后,从模型中取出每个冠-基台单元,从4个表面拍摄和分析,最终得到80个测量样本。采用影像学检查和adobephotoshop中的计算机平面测量法确定剩余水泥量,并评估水泥残留面积与整个冠-基台表面的比值。显著性设为0.05。结果:与RX相比,GC的各表面水泥残留量增加了7.4% (P < 0.05)。三个面(除中位面外)P值均< 0.05,说明组间、面间数据差异有统计学意义。所有病例(100%)都不可能完全清除骨水泥,95%的病例无法通过影像学检查检测到骨水泥残留。结论:树脂改性玻璃离聚体水泥残留较多。完全去除这两种水泥的过量是不可能的。大部分骨水泥停留在远端表面。影像学检查不能作为鉴别骨水泥过量的可靠方法。
{"title":"Influence of Cement Type on its Quality of Removal from Zirconium Oxide Implant-Supported Restorations","authors":"Egle Vindasiute-Narbute,&nbsp;Algirdas Puisys,&nbsp;Rolandas Andrijauskas,&nbsp;Gaivile Pileicikiene,&nbsp;Dominyka Malinauskaite,&nbsp;Tomas Linkevicius","doi":"10.11607/ijp.7088","DOIUrl":"https://doi.org/10.11607/ijp.7088","url":null,"abstract":"<p><strong>Purpose: </strong>To assess excess cement removal after cementation of implant-supported cementretained restorations using different cements.</p><p><strong>Materials and methods: </strong>A dental model with soft tissue imitation, 20 individual zirconium oxide abutments, and 20 zirconium oxide crowns were fabricated. Half of the restorations were cemented using resin cement (RX) and the other half with resin-modified glass-ionomer cement (GC). After cement cleaning, each crown-abutment unit was removed from the model, photographed, and analyzed from 4 surfaces, resulting in a final sample size of 80 measurements. Radiographic examination and the computerized planimetric method in Adobe Photoshop were used to determine the amount of the cement left and to evaluate the ratio between the area of cement residue and the whole crown-abutment surface. The significance was set to .05.</p><p><strong>Results: </strong>GC resulted in 7.4% more cement residue on all surfaces (P < .05) than RX. The P value on three of the surfaces (all except mesial) was < .05, meaning that the data were statistically significantly different between groups and surfaces. Absolute removal of the cement was impossible in all cases (100%), and in 95% of the cases, cement remnants could not be detected radiographically.</p><p><strong>Conclusion: </strong>More undetected cement remains when using resin-modified glass-ionomer cement. It was impossible to remove excess of both types of cements completely. Most of the cement remains on the distal surface. Radiographic examination could not be considered as a reliable method to identify excess cement.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10089020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
期刊
International Journal of Prosthodontics
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1