Abstract. The effect of pipe fittings (mainly T-pieces) on particle accumulation in drinking water distribution networks were shown in this work. The online measurements of flow and turbidity for cast iron, polyethylene and polyvinyl chloride pipe sections were linked with analysis of pipe geometry. Up to 0.29 kg of the total amount mobilized in T-pieces ranging from DN 100/100–DN 250/250. The accumulated amount of particles in fittings was defined as J and introduced into the existing turbidity model PODDS (prediction of discoloration in distribution systems) proposed by Boxall et al. (2001) which describes the erosion of particles leading to discoloration events in drinking water network viz sections of straight pipes. However, this work does not interpret mobilization of particles in pipe fittings which have been considered in this article. T-pieces were the object of this study and depending of the diameter or daily flow velocity, the coefficient J varied from 1.16 to 8.02. The study showed that pipe fittings act as catchment areas for particle accumulation in drinking water networks.
{"title":"Accumulation and modeling of particles in drinking water pipe fittings","authors":"Kaspars Neilands, M. Bernats, J. Rubulis","doi":"10.5194/DWES-5-47-2012","DOIUrl":"https://doi.org/10.5194/DWES-5-47-2012","url":null,"abstract":"Abstract. The effect of pipe fittings (mainly T-pieces) on particle accumulation in drinking water distribution networks were shown in this work. The online measurements of flow and turbidity for cast iron, polyethylene and polyvinyl chloride pipe sections were linked with analysis of pipe geometry. Up to 0.29 kg of the total amount mobilized in T-pieces ranging from DN 100/100–DN 250/250. The accumulated amount of particles in fittings was defined as J and introduced into the existing turbidity model PODDS (prediction of discoloration in distribution systems) proposed by Boxall et al. (2001) which describes the erosion of particles leading to discoloration events in drinking water network viz sections of straight pipes. However, this work does not interpret mobilization of particles in pipe fittings which have been considered in this article. T-pieces were the object of this study and depending of the diameter or daily flow velocity, the coefficient J varied from 1.16 to 8.02. The study showed that pipe fittings act as catchment areas for particle accumulation in drinking water networks.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"5 1","pages":"47-57"},"PeriodicalIF":0.0,"publicationDate":"2012-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-5-47-2012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. Modelling of contamination spread and location of a contamination source in a water distribution network is an important task. There are several simulation tools developed, however the significant part of them is based on hydraulic models that need node demands as input data that sometimes may result in false negative results and put users at risk. The paper considers applicability of a real-time flow direction data based model for contaminant transport in a distribution network of a city and evaluates the optimal number of flow direction sensors. Simulation data suggest that the model is applicable for the distribution network of the city of Riga and that the optimal number of sensors in this case is around 200.
{"title":"Modelling water quality in drinking water distribution networks from real-time direction data","authors":"S. Nazarovs, Sandis Dejus, T. Juhna","doi":"10.5194/DWES-5-39-2012","DOIUrl":"https://doi.org/10.5194/DWES-5-39-2012","url":null,"abstract":"Abstract. Modelling of contamination spread and location of a contamination source in a water distribution network is an important task. There are several simulation tools developed, however the significant part of them is based on hydraulic models that need node demands as input data that sometimes may result in false negative results and put users at risk. The paper considers applicability of a real-time flow direction data based model for contaminant transport in a distribution network of a city and evaluates the optimal number of flow direction sensors. Simulation data suggest that the model is applicable for the distribution network of the city of Riga and that the optimal number of sensors in this case is around 200.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"5 1","pages":"39-45"},"PeriodicalIF":0.0,"publicationDate":"2012-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-5-39-2012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71220961","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. Water supply systems (WSSs) are vital infrastructures for the well-being of people today. To achieve good customer satisfaction the water supply service must always be able to meet people's needs, in terms of both quantity and quality. But unpredictable extreme conditions can cause severe damage to WSSs and lead to poorer levels of service or even to their failure. Operators dealing with a system's day-to-day operation know that events like burst water mains can compromise the functioning of all or part of a system. To increase a system's reliability, therefore, designs should take into account operating conditions other than normal ones. Recent approaches based on robust optimization can be used to solve optimization problems which involve uncertainty and can find designs which are able to cope with a range of operating conditions. This paper presents a robust optimization model for the optimal design of water supply systems operating under different circumstances. The model presented here uses a hydraulic simulator linked to an optimizer based on a simulated annealing heuristic. The results show that robustness can be included in several ways for varying levels reliability and that it leads to more reliable designs for only small cost increases.
{"title":"Robust optimization methodologies for water supply systems design","authors":"J. Marques, M. Cunha, J. Sousa, D. Savić","doi":"10.5194/DWES-5-31-2012","DOIUrl":"https://doi.org/10.5194/DWES-5-31-2012","url":null,"abstract":"Abstract. Water supply systems (WSSs) are vital infrastructures for the well-being of people today. To achieve good customer satisfaction the water supply service must always be able to meet people's needs, in terms of both quantity and quality. But unpredictable extreme conditions can cause severe damage to WSSs and lead to poorer levels of service or even to their failure. Operators dealing with a system's day-to-day operation know that events like burst water mains can compromise the functioning of all or part of a system. To increase a system's reliability, therefore, designs should take into account operating conditions other than normal ones. Recent approaches based on robust optimization can be used to solve optimization problems which involve uncertainty and can find designs which are able to cope with a range of operating conditions. This paper presents a robust optimization model for the optimal design of water supply systems operating under different circumstances. The model presented here uses a hydraulic simulator linked to an optimizer based on a simulated annealing heuristic. The results show that robustness can be included in several ways for varying levels reliability and that it leads to more reliable designs for only small cost increases.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"5 1","pages":"31-37"},"PeriodicalIF":0.0,"publicationDate":"2012-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-5-31-2012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71220869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. To guarantee a good water quality at the customers tap, natural organic matter (NOM) should be (partly) removed during drinking water treatment. The objective of this research was to improve the biological stability of the produced water by incorporating anion exchange (IEX) for NOM removal. Different placement positions of IEX in the treatment lane (IEX positioned before coagulation, before ozonation or after slow sand filtration) and two IEX configurations (MIEX® and fluidized IEX (FIX)) were compared on water quality as well as costs. For this purpose the pre-treatment plant at Loenderveen and production plant Weesperkarspel of Waternet were used as a case study. Both, MIEX® and FIX were able to remove NOM (mainly the HS fraction) to a high extent. NOM removal can be done efficiently before ozonation and after slow sand filtration. The biological stability, in terms of assimilable organic carbon, biofilm formation rate and dissolved organic carbon, was improved by incorporating IEX for NOM removal. The operational costs were assumed to be directly dependent of the NOM removal rate and determined the difference between the IEX positions. The total costs for IEX for the three positions were approximately equal (0.0631 € m−3), however the savings on following treatment processes caused a cost reduction for the IEX positions before coagulation and before ozonation compared to IEX positioned after slow sand filtration. IEX positioned before ozonation was most cost effective and improved the biological stability of the treated water.
{"title":"Natural organic matter removal by ion exchange at different positions in the drinking water treatment lane","authors":"A. Grefte, M. Dignum, E. Cornelissen, L. Rietveld","doi":"10.5194/DWES-6-1-2013","DOIUrl":"https://doi.org/10.5194/DWES-6-1-2013","url":null,"abstract":"Abstract. To guarantee a good water quality at the customers tap, natural organic matter (NOM) should be (partly) removed during drinking water treatment. The objective of this research was to improve the biological stability of the produced water by incorporating anion exchange (IEX) for NOM removal. Different placement positions of IEX in the treatment lane (IEX positioned before coagulation, before ozonation or after slow sand filtration) and two IEX configurations (MIEX® and fluidized IEX (FIX)) were compared on water quality as well as costs. For this purpose the pre-treatment plant at Loenderveen and production plant Weesperkarspel of Waternet were used as a case study. Both, MIEX® and FIX were able to remove NOM (mainly the HS fraction) to a high extent. NOM removal can be done efficiently before ozonation and after slow sand filtration. The biological stability, in terms of assimilable organic carbon, biofilm formation rate and dissolved organic carbon, was improved by incorporating IEX for NOM removal. The operational costs were assumed to be directly dependent of the NOM removal rate and determined the difference between the IEX positions. The total costs for IEX for the three positions were approximately equal (0.0631 € m−3), however the savings on following treatment processes caused a cost reduction for the IEX positions before coagulation and before ozonation compared to IEX positioned after slow sand filtration. IEX positioned before ozonation was most cost effective and improved the biological stability of the treated water.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"6 1","pages":"1-10"},"PeriodicalIF":0.0,"publicationDate":"2012-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. The addition of labile organic carbon (LOC) to enhance the biodegradation rate of dissolved organic carbon (DOC) in biological columns was studied. Acetate standard solution (NaAc) and Luria Bertrani (LB) medium were used as LOC as biostimulants in glass column system used for measurements of biodegradable dissolved organic carbon (BDOC). The addition of LOC related with the increase of total DOC in sample. The concentration of BDOC increased up to 7 and 5 times and was utilized after 24 min. contact time. The biodegradation rate constant was increased at least 26 times during adaptation-biostimulation period. There was a strong positive correlation between the biodegradation rate constant and the concentration of BDOC. Biostimulation period ranged from 24 to 53 h for NaAc biostimulant and from 20 to 168 h for LB. The study has shown that LOC could be used as stimulator to enhance the biodegradation rate of DOC during biofiltration.
{"title":"Effect of biostimulation on biodegradation of dissolved organic carbon in biological filters","authors":"K. Tihomirova, A. Briedis, J. Rubulis, T. Juhna","doi":"10.5194/DWES-5-23-2012","DOIUrl":"https://doi.org/10.5194/DWES-5-23-2012","url":null,"abstract":"Abstract. The addition of labile organic carbon (LOC) to enhance the biodegradation rate of dissolved organic carbon (DOC) in biological columns was studied. Acetate standard solution (NaAc) and Luria Bertrani (LB) medium were used as LOC as biostimulants in glass column system used for measurements of biodegradable dissolved organic carbon (BDOC). The addition of LOC related with the increase of total DOC in sample. The concentration of BDOC increased up to 7 and 5 times and was utilized after 24 min. contact time. The biodegradation rate constant was increased at least 26 times during adaptation-biostimulation period. There was a strong positive correlation between the biodegradation rate constant and the concentration of BDOC. Biostimulation period ranged from 24 to 53 h for NaAc biostimulant and from 20 to 168 h for LB. The study has shown that LOC could be used as stimulator to enhance the biodegradation rate of DOC during biofiltration.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"5 1","pages":"23-29"},"PeriodicalIF":0.0,"publicationDate":"2012-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-5-23-2012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71220857","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. The objective of this paper was to describe the impact of climate change on the Mississippi River flood hazard in the New Orleans area. This city has a unique flood risk management challenge, heavily influenced by climate change, since it faces flood hazards from multiple geographical locations (e.g. Lake Pontchartrain and Mississippi River) and multiple sources (hurricane, river, rainfall). Also the low elevation and significant subsidence rate of the Greater New Orleans area poses a high risk and challenges the water management of this urban area. Its vulnerability to flooding became dramatically apparent during Hurricane Katrina in 2005 with huge economic losses and a large number of casualties. A SOBEK Rural 1DFLOW model was set up to simulate the general hydrodynamics. This model included the two important spillways that are operated during high flow conditions. A weighted multi-criteria calibration procedure was performed to calibrate the model for high flows. Validation for floods in 2011 indicated a reasonable performance for high flows and clearly demonstrated the influence of the spillways. 32 different scenarios were defined which included the relatively large sea level rise and the changing discharge regime that is expected due to climate change. The impact of these scenarios on the water levels near New Orleans were analysed by the hydrodynamic model. Results showed that during high flows New Orleans will not be affected by varying discharge regimes, since the presence of the spillways ensures a constant discharge through the city. In contrary, sea level rise is expected to push water levels upwards. The effect of sea level rise will be noticeable even more than 470 km upstream. Climate change impacts necessitate a more frequent use of the spillways and opening strategies that are based on stages.
{"title":"The large-scale impact of climate change to Mississippi flood hazard in New Orleans","authors":"T. Driessen, M. Ledden","doi":"10.5194/DWES-6-81-2013","DOIUrl":"https://doi.org/10.5194/DWES-6-81-2013","url":null,"abstract":"Abstract. The objective of this paper was to describe the impact of climate change on the Mississippi River flood hazard in the New Orleans area. This city has a unique flood risk management challenge, heavily influenced by climate change, since it faces flood hazards from multiple geographical locations (e.g. Lake Pontchartrain and Mississippi River) and multiple sources (hurricane, river, rainfall). Also the low elevation and significant subsidence rate of the Greater New Orleans area poses a high risk and challenges the water management of this urban area. Its vulnerability to flooding became dramatically apparent during Hurricane Katrina in 2005 with huge economic losses and a large number of casualties. A SOBEK Rural 1DFLOW model was set up to simulate the general hydrodynamics. This model included the two important spillways that are operated during high flow conditions. A weighted multi-criteria calibration procedure was performed to calibrate the model for high flows. Validation for floods in 2011 indicated a reasonable performance for high flows and clearly demonstrated the influence of the spillways. 32 different scenarios were defined which included the relatively large sea level rise and the changing discharge regime that is expected due to climate change. The impact of these scenarios on the water levels near New Orleans were analysed by the hydrodynamic model. Results showed that during high flows New Orleans will not be affected by varying discharge regimes, since the presence of the spillways ensures a constant discharge through the city. In contrary, sea level rise is expected to push water levels upwards. The effect of sea level rise will be noticeable even more than 470 km upstream. Climate change impacts necessitate a more frequent use of the spillways and opening strategies that are based on stages.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"6 1","pages":"81-87"},"PeriodicalIF":0.0,"publicationDate":"2012-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-6-81-2013","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221780","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take advantage of the demand variability and can decrease energy consumption significantly. One of the issues in using variable speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper aims to provide a comprehensive discussion about the components of WDS that incorporate variable speed pumps (including electric motors, variable frequency drives and the pumps themselves) to provide an insight of ways of increasing the system efficiency and hence to reduce energy consumption. In addition, specific attention is given to selection of motor types, sizing, duty cycle of pump (ratio of on-time and time period), losses due to installation and motor faults. All these factors affect the efficiency of motor drive/pump system.
{"title":"Assessing variable speed pump efficiency in water distribution systems","authors":"A. Marchi, A. Simpson, N. Ertugrul","doi":"10.5194/DWES-5-15-2012","DOIUrl":"https://doi.org/10.5194/DWES-5-15-2012","url":null,"abstract":"Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take advantage of the demand variability and can decrease energy consumption significantly. One of the issues in using variable speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper aims to provide a comprehensive discussion about the components of WDS that incorporate variable speed pumps (including electric motors, variable frequency drives and the pumps themselves) to provide an insight of ways of increasing the system efficiency and hence to reduce energy consumption. In addition, specific attention is given to selection of motor types, sizing, duty cycle of pump (ratio of on-time and time period), losses due to installation and motor faults. All these factors affect the efficiency of motor drive/pump system.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"5 1","pages":"15-21"},"PeriodicalIF":0.0,"publicationDate":"2012-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-5-15-2012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71220706","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. In water treatment processes, aluminum salts are widely used as coagulation chemical. High dose of aluminum has been proved to be at least a minor health risk and some evidence points out that aluminum could increase the risk of Alzheimer's disease. Thus it is important to minimize the amount of residual aluminum in drinking water and water used at food industry. In this study, the data of a water treatment plant (WTP) was analyzed and the residual aluminum in drinking water was predicted using Multiple Linear Regression (MLR) and Artificial Neural Network (ANN) models. The purpose was to find out which variables affect the amount of residual aluminum and create simple and reliable prediction models which can be used in an early warning system (EWS). Accuracy of ANN and MLR models were compared. The new nonlinear scaling method based on generalized norms and skewness was used to scale all measurement variables to range [−2...+2] before data-analysis and modeling. The effect of data pre-processing was studied by comparing prediction results to ones achieved in an earlier study. Results showed that it is possible to predict the baseline level of residual aluminum in drinking water with a simple model. Variables that affected the most the amount of residual aluminum were among others: raw water temperature, raw water KMnO4 and PAC/KMnO4 (Poly-Aluminum Chloride/Potassium permanganate)-ratio. The accuracies of MLR and ANN models were found to be almost the same. Study also showed that data pre-processing affects to the final prediction result.
{"title":"Predicting the residual aluminum level in water treatment process","authors":"J. Tomperi, M. Pelo, K. Leiviskä","doi":"10.5194/DWES-6-39-2013","DOIUrl":"https://doi.org/10.5194/DWES-6-39-2013","url":null,"abstract":"Abstract. In water treatment processes, aluminum salts are widely used as coagulation chemical. High dose of aluminum has been proved to be at least a minor health risk and some evidence points out that aluminum could increase the risk of Alzheimer's disease. Thus it is important to minimize the amount of residual aluminum in drinking water and water used at food industry. In this study, the data of a water treatment plant (WTP) was analyzed and the residual aluminum in drinking water was predicted using Multiple Linear Regression (MLR) and Artificial Neural Network (ANN) models. The purpose was to find out which variables affect the amount of residual aluminum and create simple and reliable prediction models which can be used in an early warning system (EWS). Accuracy of ANN and MLR models were compared. The new nonlinear scaling method based on generalized norms and skewness was used to scale all measurement variables to range [−2...+2] before data-analysis and modeling. The effect of data pre-processing was studied by comparing prediction results to ones achieved in an earlier study. Results showed that it is possible to predict the baseline level of residual aluminum in drinking water with a simple model. Variables that affected the most the amount of residual aluminum were among others: raw water temperature, raw water KMnO4 and PAC/KMnO4 (Poly-Aluminum Chloride/Potassium permanganate)-ratio. The accuracies of MLR and ANN models were found to be almost the same. Study also showed that data pre-processing affects to the final prediction result.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"42 1","pages":"39-46"},"PeriodicalIF":0.0,"publicationDate":"2012-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221527","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. Financial resources are crucial to improve existing urban drinking water supply in developing countries typically characterized by low cost recovery rates and high and rapidly growing demand for more reliable services. This study examines the willingness to pay for improved urban drinking water supply employing a choice model (CM) in an urban context in Ethiopia, Hawassa, with a household survey of 170 respondents. The design of the choice model allows the estimation of the values of two attributes of urban drinking water service (extra day water delivery per week and safer water). The findings indicate that households are willing to pay up to 60% extra for improved levels of water supply over and above their current water bill. Especially those households living in the poorest part of the city with the lowest service levels demonstrate that they are willing to pay more despite significant income constraints they are facing. Women value the improvement of water quality most, while a significant effect is found for averting behavior and expenditures. The estimated economic values can be used in policy appraisals of investment decisions.
{"title":"How much are households willing to contribute to the cost recovery of drinking water supply? Results from a household survey","authors":"S. Tarfasa","doi":"10.5194/DWES-6-33-2013","DOIUrl":"https://doi.org/10.5194/DWES-6-33-2013","url":null,"abstract":"Abstract. Financial resources are crucial to improve existing urban drinking water supply in developing countries typically characterized by low cost recovery rates and high and rapidly growing demand for more reliable services. This study examines the willingness to pay for improved urban drinking water supply employing a choice model (CM) in an urban context in Ethiopia, Hawassa, with a household survey of 170 respondents. The design of the choice model allows the estimation of the values of two attributes of urban drinking water service (extra day water delivery per week and safer water). The findings indicate that households are willing to pay up to 60% extra for improved levels of water supply over and above their current water bill. Especially those households living in the poorest part of the city with the lowest service levels demonstrate that they are willing to pay more despite significant income constraints they are facing. Women value the improvement of water quality most, while a significant effect is found for averting behavior and expenditures. The estimated economic values can be used in policy appraisals of investment decisions.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"6 1","pages":"33-38"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221500","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Abstract. This study reports the occurrences of organochlorine pesticides (OCPs) in the Ganga river basin covering 3 states, i.e., Uttarakhand, Uttar Pradesh and Bihar comprising 72% of total river stretch consisting of 82 sampling points covered through 3 sampling campaigns. Samples were monitored for 16 major OCPs, including hexachlorocyclohexanes (HCHs), Endosulfan group, Aldrin group, DDTs and Heptachlor group pesticides. The results showed the ng L−1 levels contamination of OCPs in all the stretches sampled during these campaigns. The results also revealed that different types of OCPs were dominating in different stretches in accordance with the land use practices and agricultural runoff generated from those stretches. HCHs were most frequently detected (detection rate = 75%) in mountainous stretch; Endosulfans were prominent in UP (detection rate = 75%) stretch while in BR stretch Aldrin group pesticides were paramount (detection rate = 34%). Source apportionment of the OCP's revealed that in the upper reaches of the Ganges i.e., in the state of Uttarakhand, the glacial melt may be responsible for the presence of OCP's. In the lower reaches, intensive agriculture and industrial activities may be significantly contributing these pesticides. The samples from tributaries of Ganga river were found to contain higher numbers of pesticides as well as higher concentrations. The maximum total pesticide concentration in an individual sample during these sampling campaigns was found in the Son river sample (0.17 μg L−1, Location: Koilwar, Bhojpur, Bihar).
{"title":"Status of organochlorine pesticides in Ganga river basin: anthropogenic or glacial?","authors":"P. K. Mutiyar, A. Mittal","doi":"10.5194/DWES-6-69-2013","DOIUrl":"https://doi.org/10.5194/DWES-6-69-2013","url":null,"abstract":"Abstract. This study reports the occurrences of organochlorine pesticides (OCPs) in the Ganga river basin covering 3 states, i.e., Uttarakhand, Uttar Pradesh and Bihar comprising 72% of total river stretch consisting of 82 sampling points covered through 3 sampling campaigns. Samples were monitored for 16 major OCPs, including hexachlorocyclohexanes (HCHs), Endosulfan group, Aldrin group, DDTs and Heptachlor group pesticides. The results showed the ng L−1 levels contamination of OCPs in all the stretches sampled during these campaigns. The results also revealed that different types of OCPs were dominating in different stretches in accordance with the land use practices and agricultural runoff generated from those stretches. HCHs were most frequently detected (detection rate = 75%) in mountainous stretch; Endosulfans were prominent in UP (detection rate = 75%) stretch while in BR stretch Aldrin group pesticides were paramount (detection rate = 34%). Source apportionment of the OCP's revealed that in the upper reaches of the Ganges i.e., in the state of Uttarakhand, the glacial melt may be responsible for the presence of OCP's. In the lower reaches, intensive agriculture and industrial activities may be significantly contributing these pesticides. The samples from tributaries of Ganga river were found to contain higher numbers of pesticides as well as higher concentrations. The maximum total pesticide concentration in an individual sample during these sampling campaigns was found in the Son river sample (0.17 μg L−1, Location: Koilwar, Bhojpur, Bihar).","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"6 1","pages":"69-80"},"PeriodicalIF":0.0,"publicationDate":"2012-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-6-69-2013","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71221709","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}