There are presented the developments ensured by a new worldwide flow measurement structure, based on the reaction force, "the extended reaction flowmeter" ,elaborated by the first author, the subject matter of the patent application filed with European Patent Office EP 21020546, together other reaction flowmeters without moving parts. Initially are synthetically reitered the constructive and structural specificities of "the extended reaction flowmeters "(shortly "ERF"). Then, starting from the facilities offered by the specific structural scheme of the ERF, significant simplified compared to that of the known compound flowmeters, are presented the developments offered by the using of this new flow measurement structure based on reaction force, by describing the improuved results achieved by two constructive variants of ERF, regarding the binomial of the two essential features (turndown and accuracy, interrelated of the flowmeters, by achieving a large extension of the turndown to very important values, correlated with an optimal range of the accuracy values.
{"title":"Developments by a new flow measurement structure based on reaction force. Extended reaction flowmeters","authors":"H. M. Moțit, P. Maté","doi":"10.21014/tc9-2022.112","DOIUrl":"https://doi.org/10.21014/tc9-2022.112","url":null,"abstract":"There are presented the developments ensured by a new worldwide flow measurement structure, based on the reaction force, \"the extended reaction flowmeter\" ,elaborated by the first author, the subject matter of the patent application filed with European Patent Office EP 21020546, together other reaction flowmeters without moving parts. Initially are synthetically reitered the constructive and structural specificities of \"the extended reaction flowmeters \"(shortly \"ERF\"). Then, starting from the facilities offered by the specific structural scheme of the ERF, significant simplified compared to that of the known compound flowmeters, are presented the developments offered by the using of this new flow measurement structure based on reaction force, by describing the improuved results achieved by two constructive variants of ERF, regarding the binomial of the two essential features (turndown and accuracy, interrelated of the flowmeters, by achieving a large extension of the turndown to very important values, correlated with an optimal range of the accuracy values.","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80799289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Overview of differences between electronic and mechanical domestic cold water meter","authors":"A. Borchling, C. Kroner","doi":"10.21014/tc9-2022.107","DOIUrl":"https://doi.org/10.21014/tc9-2022.107","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79587914","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
In order to improve the performance of the old Stack Simulator, NIM built two new facilities. One is a close loop wind tunnel, which can simulate the real flue gas conditions. The wind tunnel can change the flow rate, temperature, pressure, gas composition and turbulence in the test section. It is used to calibrate the velocity measurement devices such as three-dimensional pitot tubes used in Relative Accuracy Test Audit (RATA). Another facility is a new Stack Simulator, which can simulate the flow field conditions in the real stack. It is used to evaluate the average velocity measurement of RATA devices.
{"title":"Performance Improvement of Stack Simulator","authors":"Liang Zhang, Hulin Guo, Guixiang Lu, Yucheng Chen","doi":"10.21014/tc9-2022.147","DOIUrl":"https://doi.org/10.21014/tc9-2022.147","url":null,"abstract":"In order to improve the performance of the old Stack Simulator, NIM built two new facilities. One is a close loop wind tunnel, which can simulate the real flue gas conditions. The wind tunnel can change the flow rate, temperature, pressure, gas composition and turbulence in the test section. It is used to calibrate the velocity measurement devices such as three-dimensional pitot tubes used in Relative Accuracy Test Audit (RATA). Another facility is a new Stack Simulator, which can simulate the flow field conditions in the real stack. It is used to evaluate the average velocity measurement of RATA devices.","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76906758","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on the influence of installation angle on pitot tube in wind tunnel","authors":"Z. Zhang, M. Miao, Wenjia Li","doi":"10.21014/tc9-2022.058","DOIUrl":"https://doi.org/10.21014/tc9-2022.058","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75206815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Q. Pan, W. Lin, Y. Liu, L. Zhang, J. Wang, J. Peng
{"title":"Traceability of ultrasonic transit time based on relative displacement method","authors":"Q. Pan, W. Lin, Y. Liu, L. Zhang, J. Wang, J. Peng","doi":"10.21014/tc9-2022.066","DOIUrl":"https://doi.org/10.21014/tc9-2022.066","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74785471","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of the pVTt Gas Flow Standard with Active Thermal Compensation","authors":"Hu Wenqing, X. Zhipeng, Zhang Gaoming, Guo Jing","doi":"10.21014/tc9-2022.111","DOIUrl":"https://doi.org/10.21014/tc9-2022.111","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75646405","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of the Variable Geometry of the Diverter Nozzle on the Metrological Characteristics of a Calibration Unit with Weighing Devices","authors":"A. Korneev, A. Shchelchkov, R. A. Korneev","doi":"10.21014/tc9-2022.003","DOIUrl":"https://doi.org/10.21014/tc9-2022.003","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75834533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chunhui Li, B. Mickan, Mengna Li, Jia Ren, Yan Wu, Ming Xu
{"title":"The comparison of the gas flow primary standard facilities at high pressure","authors":"Chunhui Li, B. Mickan, Mengna Li, Jia Ren, Yan Wu, Ming Xu","doi":"10.21014/tc9-2022.001","DOIUrl":"https://doi.org/10.21014/tc9-2022.001","url":null,"abstract":"","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90412452","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}