首页 > 最新文献

中国防雷最新文献

英文 中文
AKUNU Atmospheric Network as Part of the GeoRays Project in Argentina AKUNU大气网络是阿根廷geays项目的一部分
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627348
Adrián Stacul, Daniel Pastafiglia, Ariel Dalmas Di Giovanni, M. Morales, G. Nicora, M. Rubinstein
At present, data on atmospheric parameters are used in climatology, engineering, weather forecasting, agriculture, and other fields of research and applied science. In 2013, a group of researchers, including Dr. Gabriela Nicora, Prof. Marcos Rubinstein, Prof. Vernon Cooray, Prof. Francisco Román, and Prof. Farhad Rachidi declared themselves in favor of the development of an inexpensive sensor network, called AKUNU, which has for objective to collect atmospheric data in low- and middle-income countries. From the first prototypes, a data acquisition system was developed that records the electric field generated by a return stroke from a lightning using low-cost electronics. This was achieved between the University of Applied Sciences and Arts Western Switzerland (HEIG-VD) and the Institute of Scientific and Technical Research for Defense (CITEDEF of Argentina), where the Digital Techniques laboratory in conjunction with the Atmosphere laboratory continues and expands this research field with the development of a network of sensors to capture the electric field from atmospheric discharges, and of software applications for its analysis.
目前,大气参数数据被用于气候学、工程、天气预报、农业和其他研究和应用科学领域。2013年,包括加布里埃拉·尼科拉(Gabriela Nicora)博士、马科斯·鲁宾斯坦(Marcos Rubinstein)教授、弗农·库雷(Vernon Cooray)教授、弗朗西斯科·Román教授和法尔哈德·拉基迪(Farhad Rachidi)教授在内的一组研究人员宣布,他们支持开发一个名为AKUNU的廉价传感器网络,该网络的目标是收集中低收入国家的大气数据。从第一个原型开始,开发了一个数据采集系统,该系统使用低成本电子设备记录闪电回击产生的电场。这是在瑞士西部应用科学与艺术大学(HEIG-VD)和阿根廷国防科学技术研究所(CITEDEF)之间实现的,其中数字技术实验室与大气实验室一起继续并扩展了这一研究领域,开发了传感器网络,用于捕获大气放电中的电场,并开发了用于分析的软件应用程序。
{"title":"AKUNU Atmospheric Network as Part of the GeoRays Project in Argentina","authors":"Adrián Stacul, Daniel Pastafiglia, Ariel Dalmas Di Giovanni, M. Morales, G. Nicora, M. Rubinstein","doi":"10.1109/ICLPandSIPDA54065.2021.9627348","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627348","url":null,"abstract":"At present, data on atmospheric parameters are used in climatology, engineering, weather forecasting, agriculture, and other fields of research and applied science. In 2013, a group of researchers, including Dr. Gabriela Nicora, Prof. Marcos Rubinstein, Prof. Vernon Cooray, Prof. Francisco Román, and Prof. Farhad Rachidi declared themselves in favor of the development of an inexpensive sensor network, called AKUNU, which has for objective to collect atmospheric data in low- and middle-income countries. From the first prototypes, a data acquisition system was developed that records the electric field generated by a return stroke from a lightning using low-cost electronics. This was achieved between the University of Applied Sciences and Arts Western Switzerland (HEIG-VD) and the Institute of Scientific and Technical Research for Defense (CITEDEF of Argentina), where the Digital Techniques laboratory in conjunction with the Atmosphere laboratory continues and expands this research field with the development of a network of sensors to capture the electric field from atmospheric discharges, and of software applications for its analysis.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82582314","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Remote measurements of lightning return stroke peak currents based on electric and acoustic signals 基于电声信号的雷电回击峰值电流的远程测量
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627433
A. Leal
Lightning return-stroke peak current is one of the most important parameters for lightning protection purposes. It can be directly measured in instrumented tower facilities or using artificial-initiated lightning. Lightning peak currents can be also estimated using field-to-current empirical formulas. These formulas use the electric field peak radiation and distance between the lightning channel and the measuring station to estimate lightning peak currents. In this work, we use wideband electric fields (160 Hz -10 MHz) and acoustic measurements of 54 negative cloud to ground flashes to estimate lightning strike distance and lightning return-stoke peak currents remotely. We use the time-to-thunder method to determine the lightning strike distance. We compare our results for distance and peak current estimations with data reported by the Earth Networks Global Lightning Network (ENGLN).
雷电回击峰值电流是防雷最重要的参数之一。它可以直接测量仪器塔设施或使用人工引发的闪电。雷电峰值电流也可以用场电流经验公式来估计。这些公式利用电场峰值辐射和闪电通道与测量站之间的距离来估计闪电峰值电流。在这项工作中,我们使用宽带电场(160 Hz -10 MHz)和54次负云对地闪光的声学测量来远程估计雷击距离和闪电回波峰值电流。我们使用雷电时间法来确定雷击距离。我们将我们的距离和峰值电流估计结果与地球网络全球闪电网络(ENGLN)报告的数据进行了比较。
{"title":"Remote measurements of lightning return stroke peak currents based on electric and acoustic signals","authors":"A. Leal","doi":"10.1109/ICLPandSIPDA54065.2021.9627433","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627433","url":null,"abstract":"Lightning return-stroke peak current is one of the most important parameters for lightning protection purposes. It can be directly measured in instrumented tower facilities or using artificial-initiated lightning. Lightning peak currents can be also estimated using field-to-current empirical formulas. These formulas use the electric field peak radiation and distance between the lightning channel and the measuring station to estimate lightning peak currents. In this work, we use wideband electric fields (160 Hz -10 MHz) and acoustic measurements of 54 negative cloud to ground flashes to estimate lightning strike distance and lightning return-stoke peak currents remotely. We use the time-to-thunder method to determine the lightning strike distance. We compare our results for distance and peak current estimations with data reported by the Earth Networks Global Lightning Network (ENGLN).","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89630875","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Far Electric Field Waveforms Produced by Rocket-Triggered Lightning Strokes and Subsequent Strokes in Natural Lightning 自然闪电中火箭触发雷击与后续雷击产生的远电场波形比较
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627431
Z. Ding, S. Chen, V. Rakov, Y. Zhu, I. Kereszy, M. Uman
Using electric field records obtained at the Lightning Observatory in Gainesville (LOG), Florida, we examined in detail the characteristics of far electric field waveforms produced by RTL (rocket-triggered lightning) and natural cloud-to-ground (CG) lightning. Electric field waveforms of 139 return strokes in flashes triggered by a rocket extending a grounded wire toward the overhead thundercloud in years 2013 to 2016 and 184 subsequent return strokes in natural lightning flashes from years 2013 to 2015 are used for this analysis. All strokes transported negative charge to ground. Similarities and dissimilarities of waveform parameters are examined and discussed. This is the first detailed comparison of electric field waveforms of RTL strokes and subsequent strokes in natural CGs recorded at approximately the same distance (some tens of kilometers) and by the same instrumentation.
利用在佛罗里达州盖恩斯维尔闪电天文台(LOG)获得的电场记录,我们详细研究了RTL(火箭触发闪电)和自然云对地闪电(CG)产生的远电场波形的特征。本文采用2013 - 2016年火箭将接地线向头顶雷云延伸引发的139次闪电回击的电场波形,以及2013 - 2015年自然闪电回击后的184次闪电回击的电场波形进行分析。所有的击打都将负电荷输送到地面。对波形参数的异同进行了分析和讨论。这是在大约相同距离(约几十公里)使用相同仪器记录的自然断层中RTL冲程和后续冲程的电场波形的首次详细比较。
{"title":"Comparison of Far Electric Field Waveforms Produced by Rocket-Triggered Lightning Strokes and Subsequent Strokes in Natural Lightning","authors":"Z. Ding, S. Chen, V. Rakov, Y. Zhu, I. Kereszy, M. Uman","doi":"10.1109/ICLPandSIPDA54065.2021.9627431","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627431","url":null,"abstract":"Using electric field records obtained at the Lightning Observatory in Gainesville (LOG), Florida, we examined in detail the characteristics of far electric field waveforms produced by RTL (rocket-triggered lightning) and natural cloud-to-ground (CG) lightning. Electric field waveforms of 139 return strokes in flashes triggered by a rocket extending a grounded wire toward the overhead thundercloud in years 2013 to 2016 and 184 subsequent return strokes in natural lightning flashes from years 2013 to 2015 are used for this analysis. All strokes transported negative charge to ground. Similarities and dissimilarities of waveform parameters are examined and discussed. This is the first detailed comparison of electric field waveforms of RTL strokes and subsequent strokes in natural CGs recorded at approximately the same distance (some tens of kilometers) and by the same instrumentation.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81244028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Construction of an Electrostatic Sensor Network to Estimate Total Charge in an Isolated Thundercloud 用于估计孤立雷云总电荷的静电传感器网络的构建
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627450
K. Yamashita, Hironobu Fujisaka, H. Iwasaki, Kakeru Kanno, M. Hayakawa
This paper presents a methodology to estimate the quantity and location of charges in an isolated cloud based on multipoint measurements of electrostatic fields on the ground. We have newly designed and fabricated an electric field mill (EFM) and constructed an EFM network in Tochigi and Gunma prefectures, Japan. It is difficult to understand the relationship between variations of surface electrostatic field and charge distribution in the cloud. In our observation, a single cell thundercloud is focused on to assume a simple charge model inside the cloud and to simplify the calculation of the quantity and height of the point charge in the cloud. In this paper, by assuming a point charge model in the cloud, amount and height of charge in an isolated storm is estimated as an initial result. We also summarize details of the developed sensor system and the method of calibration for sensors in our EFM network.
本文提出了一种基于地面静电场多点测量的方法来估计孤立云中电荷的数量和位置。我们在日本枥木县和群马县新设计并制造了一个电场磨机(EFM),并建立了一个EFM网络。表面静电场的变化与云中电荷分布之间的关系很难理解。在我们的观测中,我们以单细胞雷云为研究对象,假设一个简单的云内电荷模型,简化云中点电荷的数量和高度的计算。本文通过在云中假设一个点电荷模型,初步估计了孤立风暴中电荷的数量和高度。我们还总结了开发的传感器系统的细节和我们的EFM网络中传感器的校准方法。
{"title":"Construction of an Electrostatic Sensor Network to Estimate Total Charge in an Isolated Thundercloud","authors":"K. Yamashita, Hironobu Fujisaka, H. Iwasaki, Kakeru Kanno, M. Hayakawa","doi":"10.1109/ICLPandSIPDA54065.2021.9627450","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627450","url":null,"abstract":"This paper presents a methodology to estimate the quantity and location of charges in an isolated cloud based on multipoint measurements of electrostatic fields on the ground. We have newly designed and fabricated an electric field mill (EFM) and constructed an EFM network in Tochigi and Gunma prefectures, Japan. It is difficult to understand the relationship between variations of surface electrostatic field and charge distribution in the cloud. In our observation, a single cell thundercloud is focused on to assume a simple charge model inside the cloud and to simplify the calculation of the quantity and height of the point charge in the cloud. In this paper, by assuming a point charge model in the cloud, amount and height of charge in an isolated storm is estimated as an initial result. We also summarize details of the developed sensor system and the method of calibration for sensors in our EFM network.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86098779","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Lightning Risk and Disaster Risk Management at the beginning of the 2020s 21世纪20年代初的闪电风险和灾害风险管理
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627393
Daniel E. Villamil, H. Rojas, Francisco Javier Vela Santamaría, Wilson Diaz
The current decade started facing great challenges in the path towards sustainable development. Less than 10 years remain to achieve the goals of the Sustainable Development Agenda adopted by all the United Nations (UN) and one of the key components in this process is disaster risk management (DRM). However, the risk from lightning plays a very small role in the global DRM scenario. This paper emphasizes the nature of lightning risk and how its estimation requires methods that may involve socio-demographic factors. The above with the intention of drawing the attention of the authorities in charge of enacting the DRM guidelines and thus get involved within the programs of the Sendai Framework for Disaster Risk Reduction 2015–2030.
本十年在实现可持续发展的道路上开始面临巨大的挑战。距离实现联合国全体通过的《可持续发展议程》的目标还有不到10年的时间,而这一进程的关键组成部分之一是灾害风险管理。然而,来自闪电的风险在全球DRM场景中扮演着非常小的角色。本文强调了闪电风险的本质,以及它的估计如何需要可能涉及社会人口因素的方法。上述内容旨在引起负责制定DRM指导方针的当局的注意,从而参与2015-2030年仙台减少灾害风险框架的方案。
{"title":"Lightning Risk and Disaster Risk Management at the beginning of the 2020s","authors":"Daniel E. Villamil, H. Rojas, Francisco Javier Vela Santamaría, Wilson Diaz","doi":"10.1109/ICLPandSIPDA54065.2021.9627393","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627393","url":null,"abstract":"The current decade started facing great challenges in the path towards sustainable development. Less than 10 years remain to achieve the goals of the Sustainable Development Agenda adopted by all the United Nations (UN) and one of the key components in this process is disaster risk management (DRM). However, the risk from lightning plays a very small role in the global DRM scenario. This paper emphasizes the nature of lightning risk and how its estimation requires methods that may involve socio-demographic factors. The above with the intention of drawing the attention of the authorities in charge of enacting the DRM guidelines and thus get involved within the programs of the Sendai Framework for Disaster Risk Reduction 2015–2030.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85570815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Total Lightning Activity Process and Parameter Characteristics at Pearl River Delta in China 中国珠江三角洲闪电活动过程及参数特征
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627436
S. Cheng, Jianguo Wang, L. Cai, Yijun Huang, Yutong Xiao, Quanxin Li
A total lightning activity process lasting 5 hours occurred on August 19, 2014 at pearl river delta in China is analyzed in detail. Based on Foshan Total Lightning Location System, the characteristics and parameters of the total lightning process are proposed. The number of lightning flashes in the thunderstorm reach to 97249, of which intra-cloud(IC) flashes account for 80.4%, cloud-to-ground(CG) flashes 18.8% and narrow bipolar events (NBE) 0.8%. The variation of IC flashes and total lightning are synchronous. More than 96.69% of the height of IC flashes are below 15 km, while 7 km to 10 km is the maximum probability area of IC flashes. The height distribution of NBE is relatively disorganized compared with IC flashes, the variation of which does not show any visible trend.
对2014年8月19日发生在中国珠江三角洲的一次持续5小时的闪电活动过程进行了详细分析。基于佛山市总闪电定位系统,提出了总闪电过程的特征和参数。雷暴中共出现97249次闪电,其中云内闪(IC)占80.4%,云对地闪(CG)占18.8%,窄双极闪(NBE)占0.8%。集成电路闪光与总闪电的变化是同步的。超过96.69%的IC闪光高度在15 km以下,而7 ~ 10 km是IC闪光的最大概率区域。与集成电路闪光相比,NBE的高度分布相对混乱,其变化没有明显的趋势。
{"title":"A Total Lightning Activity Process and Parameter Characteristics at Pearl River Delta in China","authors":"S. Cheng, Jianguo Wang, L. Cai, Yijun Huang, Yutong Xiao, Quanxin Li","doi":"10.1109/ICLPandSIPDA54065.2021.9627436","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627436","url":null,"abstract":"A total lightning activity process lasting 5 hours occurred on August 19, 2014 at pearl river delta in China is analyzed in detail. Based on Foshan Total Lightning Location System, the characteristics and parameters of the total lightning process are proposed. The number of lightning flashes in the thunderstorm reach to 97249, of which intra-cloud(IC) flashes account for 80.4%, cloud-to-ground(CG) flashes 18.8% and narrow bipolar events (NBE) 0.8%. The variation of IC flashes and total lightning are synchronous. More than 96.69% of the height of IC flashes are below 15 km, while 7 km to 10 km is the maximum probability area of IC flashes. The height distribution of NBE is relatively disorganized compared with IC flashes, the variation of which does not show any visible trend.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90059852","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Revisiting a case of lightning-caused trauma in a pregnant woman 重访一个孕妇遭雷击造成创伤的案例
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627467
J. Cristancho, J. Rodríguez, F. Roman
This paper analyzes from a technical point of view, a medical case reported in 2016 about a young couple, man and pregnant woman, stroked by a lightning flash current in the Southwestern United States, resulting in third trimester fetal injury. The most probable scenario of the case it is recreated and analyzed the evidence reported to give a probable explanation of the fetal injury under the panorama of other similar cases. The outcomes of a research work that uses an in-silico simulation in a 3D body model was used to show the current density distribution inside a human body due to a lightning-caused step potential. This study helps to give a possible explanation of the fetal injury at nine-month and the posterior disability of the baby, not given until now.
本文从技术角度分析了2016年报道的美国西南部一对年轻夫妇(男性和孕妇)被闪电电流击中导致妊娠晚期胎儿损伤的医疗案例。最可能的情况下,它是重建和分析的证据报告,以提供一个可能的解释胎儿损伤下的全景其他类似的情况。一项研究工作的结果是在一个三维身体模型中使用硅模拟,用于显示由于闪电引起的阶梯电位而导致的人体内部电流密度分布。这项研究有助于给出一个可能的解释胎儿损伤在9个月和婴儿的后路残疾,直到现在还没有给出。
{"title":"Revisiting a case of lightning-caused trauma in a pregnant woman","authors":"J. Cristancho, J. Rodríguez, F. Roman","doi":"10.1109/ICLPandSIPDA54065.2021.9627467","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627467","url":null,"abstract":"This paper analyzes from a technical point of view, a medical case reported in 2016 about a young couple, man and pregnant woman, stroked by a lightning flash current in the Southwestern United States, resulting in third trimester fetal injury. The most probable scenario of the case it is recreated and analyzed the evidence reported to give a probable explanation of the fetal injury under the panorama of other similar cases. The outcomes of a research work that uses an in-silico simulation in a 3D body model was used to show the current density distribution inside a human body due to a lightning-caused step potential. This study helps to give a possible explanation of the fetal injury at nine-month and the posterior disability of the baby, not given until now.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77824358","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Lightning Risk Assessment of a Distribution Line by Excluding a Grounding Wire and Current-Limiting Arcing Horns 排除接地线和限流弧角的配电线路雷电风险评估
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627339
S. Yasui, Masakazu Tanida, Masaya Nakagawa, Hirokazu Uenishi, Y. Kunii, Yuki Kanazawa
We need measures to establish a reasonable lightning protection design for medium-voltage distribution lines, which can reduce the capital investment costs and ensure protection against lightning strikes. We will adopt two measures to reduce the capital investment costs of the lightning protection. Firstly, removing GW from new construction or renovation of distribution lines to reduce accidents caused by the fatigue disconnection of GW. Secondly, excluded the currently installed middle-phase arcing horns for the new distribution lines to reduce the maintenance cost of the lightning arresters within the arcing horn. However, the probability of a multi-phase flashover increased when the middle-phase arcing horn was excluded in all the medium phases in the twisted distribution line. In this study, we investigated the measures to improve the lightning protection performance of medium-voltage distribution lines that omitted middle phase arcing horn using the typical distribution configuration. We confirmed to greatly reduce the risk of lightning strikes by leaving the support bracket with the grounding line when removing the GW.
我们需要采取措施,建立合理的中压配电线路防雷设计,以降低资本投资成本,保证防雷。我们将采取两项措施,降低防雷的资本投资成本。首先,在新建或改造配电线路时拆除GW,减少GW疲劳断线造成的事故。其次,在新建配电线路中省去了目前安装的中相电弧角,降低了电弧角内避雷器的维护成本。而在扭曲配电线路中所有中相均排除中相电弧角时,多相闪络的发生概率增大。本研究以典型配电配置为例,探讨了对省略中相电弧喇叭的中压配电线路提高防雷性能的措施。我们确认在拆卸GW时,将支架与接地线分开,可以大大降低雷击风险。
{"title":"Lightning Risk Assessment of a Distribution Line by Excluding a Grounding Wire and Current-Limiting Arcing Horns","authors":"S. Yasui, Masakazu Tanida, Masaya Nakagawa, Hirokazu Uenishi, Y. Kunii, Yuki Kanazawa","doi":"10.1109/ICLPandSIPDA54065.2021.9627339","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627339","url":null,"abstract":"We need measures to establish a reasonable lightning protection design for medium-voltage distribution lines, which can reduce the capital investment costs and ensure protection against lightning strikes. We will adopt two measures to reduce the capital investment costs of the lightning protection. Firstly, removing GW from new construction or renovation of distribution lines to reduce accidents caused by the fatigue disconnection of GW. Secondly, excluded the currently installed middle-phase arcing horns for the new distribution lines to reduce the maintenance cost of the lightning arresters within the arcing horn. However, the probability of a multi-phase flashover increased when the middle-phase arcing horn was excluded in all the medium phases in the twisted distribution line. In this study, we investigated the measures to improve the lightning protection performance of medium-voltage distribution lines that omitted middle phase arcing horn using the typical distribution configuration. We confirmed to greatly reduce the risk of lightning strikes by leaving the support bracket with the grounding line when removing the GW.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84478606","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance against Direct Lightning on 10kV Overhead Distribution Lines with Counterpoise Wires 10kV架空配电网配重线抗直击性能研究
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627438
Jinxin Cao, Ya-ping Du, Yuxuan Ding, Ruihan Qi, Zhe Li
This paper investigates the lightning performance on 10kV overhead distribution lines grounded with counterpoise wires under extremely low soil conductivity. A partial element equivalent circuit model considering lossy ground is used for surge analysis, and the Monte Carlo method is adopted for evaluating the flashover rate. It is found that under extremely low soil conductivity, the simple vertical grounding rod is not effective in lightning protection, while the performance is significantly increased with extended counterpoise wires. The single-row counterpoise wire with a length of pole span performs best among the schemes of concern. The single-row counterpoise wire with a half-length of pole span is a competitive one, due to a half-cost reduction but a competitive performance with a difference of less than 9%. With the same total wire length, the scheme of single-row counterpoise wire is slightly better than the parallel-row arrangement. If a higher lightning protection level is required, the improvement could be achieved by increasing the CFO level or shortening the span of two adjacent surge arresters, since increasing the length of counterpoise wire is not cost-effective.
本文研究了在极低土壤导电性条件下,用平衡线接地的10kV架空配电线路的防雷性能。浪涌分析采用考虑有损接地的部分单元等效电路模型,闪络率的评估采用蒙特卡罗方法。研究发现,在土壤电导率极低的情况下,单纯的垂直接地棒的防雷效果不明显,而延长配重线的防雷效果明显提高。在所关注的方案中,具有一定杆跨长度的单排平衡钢丝的性能最好。具有半长杆跨的单排平衡线是一种具有竞争力的平衡线,由于成本降低了一半,但竞争性能的差异小于9%。在总线长相同的情况下,单排平衡线布置方案略优于平行排平衡线布置方案。如果需要更高的防雷级别,则可以通过增加CFO级别或缩短相邻两个避雷器的跨度来实现改进,因为增加平衡线的长度并不符合成本效益。
{"title":"Performance against Direct Lightning on 10kV Overhead Distribution Lines with Counterpoise Wires","authors":"Jinxin Cao, Ya-ping Du, Yuxuan Ding, Ruihan Qi, Zhe Li","doi":"10.1109/ICLPandSIPDA54065.2021.9627438","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627438","url":null,"abstract":"This paper investigates the lightning performance on 10kV overhead distribution lines grounded with counterpoise wires under extremely low soil conductivity. A partial element equivalent circuit model considering lossy ground is used for surge analysis, and the Monte Carlo method is adopted for evaluating the flashover rate. It is found that under extremely low soil conductivity, the simple vertical grounding rod is not effective in lightning protection, while the performance is significantly increased with extended counterpoise wires. The single-row counterpoise wire with a length of pole span performs best among the schemes of concern. The single-row counterpoise wire with a half-length of pole span is a competitive one, due to a half-cost reduction but a competitive performance with a difference of less than 9%. With the same total wire length, the scheme of single-row counterpoise wire is slightly better than the parallel-row arrangement. If a higher lightning protection level is required, the improvement could be achieved by increasing the CFO level or shortening the span of two adjacent surge arresters, since increasing the length of counterpoise wire is not cost-effective.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84587878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Comparison of energy presence in IEC and real transient impulses IEC和真实瞬态脉冲中能量存在的比较
Pub Date : 2021-09-20 DOI: 10.1109/ICLPandSIPDA54065.2021.9627342
N. Sapumanage, S. Nanayakkara, S. Abegunawardana, M. Fernando, V. Cooray
This study disclosed that the IEC impulse is not an appropriate candidate to benchmark real transient over-voltages owing to have many discrepancies between them in terms of energy localization and frequencies that host such energies. However, the total energy content of the comparable IEC impulse is higher than the real transient voltages. Thus, once tested and passed the endurance at laboratories such an energy absorbing device would not fail at the field applications against single real transient voltage. However the same cannot be guaranteed against the swarm of impulses as the same cannot be tested at the test bench due to many practical constraints. The study revealed that IEC impulses can accommodate only 2.31% of the total energy until it reaches to 90% of the peak voltage, whereas the selected real transient impulses have shown that they could accommodate nearly 6% to 18% of the total incident energy before they reach to 90 % of the peak voltage. Moreover, when IEC impulse reaches to the peak, it can incident only a 9.71% of the total energy, but real transient voltages demonstrated that they have a capacity to incident nearly 30% to 45 % total energy embedded in the impulse.
这项研究表明,由于IEC脉冲在能量局部化和承载这些能量的频率方面存在许多差异,因此它不是衡量实际瞬态过电压的合适候选。然而,等效IEC脉冲的总能量含量高于实际瞬态电压。因此,一旦在实验室测试并通过了耐久性,这种能量吸收装置就不会在单个实际瞬态电压的现场应用中失败。然而,由于许多实际限制,无法在试验台上对相同的脉冲进行测试,因此无法保证对脉冲群进行相同的测试。研究表明,在达到峰值电压的90%之前,IEC脉冲只能容纳总能量的2.31%,而所选的真实瞬态脉冲表明,在达到峰值电压的90%之前,它们可以容纳总入射能量的近6%至18%。此外,当IEC脉冲达到峰值时,它只能入射总能量的9.71%,但实际瞬态电压表明,它们有能力入射脉冲中嵌入的总能量的近30%至45%。
{"title":"Comparison of energy presence in IEC and real transient impulses","authors":"N. Sapumanage, S. Nanayakkara, S. Abegunawardana, M. Fernando, V. Cooray","doi":"10.1109/ICLPandSIPDA54065.2021.9627342","DOIUrl":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627342","url":null,"abstract":"This study disclosed that the IEC impulse is not an appropriate candidate to benchmark real transient over-voltages owing to have many discrepancies between them in terms of energy localization and frequencies that host such energies. However, the total energy content of the comparable IEC impulse is higher than the real transient voltages. Thus, once tested and passed the endurance at laboratories such an energy absorbing device would not fail at the field applications against single real transient voltage. However the same cannot be guaranteed against the swarm of impulses as the same cannot be tested at the test bench due to many practical constraints. The study revealed that IEC impulses can accommodate only 2.31% of the total energy until it reaches to 90% of the peak voltage, whereas the selected real transient impulses have shown that they could accommodate nearly 6% to 18% of the total incident energy before they reach to 90 % of the peak voltage. Moreover, when IEC impulse reaches to the peak, it can incident only a 9.71% of the total energy, but real transient voltages demonstrated that they have a capacity to incident nearly 30% to 45 % total energy embedded in the impulse.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83855586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
中国防雷
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1