首页 > 最新文献

Al-Khwarizmi Engineering Journal最新文献

英文 中文
A Review on Tool Pin Geometry of Friction Stir Welding 摩擦搅拌焊接工具销几何形状综述
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.02.001
Walaa H. Ahmed, A. Kadhum, Mohd Shukor Salleh
Friction stir welding (FSW) is an innovative solid joining operation that has recently been intensively adopted in welding various similar and dissimilar metallic materials, including aluminum, steel, titanium alloys, and others. The success of FSW relies on a set of parameters like rotational speed, travel speed, axial force, tool geometry, etc. The role of tool geometry (involving both pin and shoulder design) is highly important in producing sound and high-strength weld joints. Therefore, this research aims to review the latest published works regarding the performance of different tool geometries. The discussion of the findings of the cited works revealed that each tool pin design has shown different behavior due to the various stirring efficiencies of the materials being welded. All in all, the square threaded pin had the best geometry in terms of its mechanical properties compared to other pin designs. The threaded cylinders and threaded taper are most commonly utilized and offer good joints, while the maximum joint efficiency was achieved by the square pin profile and it reached 94% in some investigations.
搅拌摩擦焊(FSW)是一种创新的固体连接操作,最近被广泛用于焊接各种相似或不相似的金属材料,包括铝、钢、钛合金等。FSW 的成功取决于一系列参数,如旋转速度、移动速度、轴向力、工具几何形状等。工具的几何形状(包括销钉和肩部设计)对于生产出良好的高强度焊点非常重要。因此,本研究旨在回顾有关不同刀具几何形状性能的最新出版著作。对所引用文献的讨论结果表明,由于被焊接材料的搅拌效率不同,每种工具销钉设计都表现出不同的性能。总而言之,与其他针脚设计相比,方形螺纹针脚的机械性能最好。螺纹圆柱和螺纹锥形是最常用的设计,可提供良好的连接效果,而方形销钉轮廓的连接效率最高,在一些研究中达到 94%。
{"title":"A Review on Tool Pin Geometry of Friction Stir Welding","authors":"Walaa H. Ahmed, A. Kadhum, Mohd Shukor Salleh","doi":"10.22153/kej.2024.02.001","DOIUrl":"https://doi.org/10.22153/kej.2024.02.001","url":null,"abstract":"Friction stir welding (FSW) is an innovative solid joining operation that has recently been intensively adopted in welding various similar and dissimilar metallic materials, including aluminum, steel, titanium alloys, and others. The success of FSW relies on a set of parameters like rotational speed, travel speed, axial force, tool geometry, etc. The role of tool geometry (involving both pin and shoulder design) is highly important in producing sound and high-strength weld joints. Therefore, this research aims to review the latest published works regarding the performance of different tool geometries. The discussion of the findings of the cited works revealed that each tool pin design has shown different behavior due to the various stirring efficiencies of the materials being welded. All in all, the square threaded pin had the best geometry in terms of its mechanical properties compared to other pin designs. The threaded cylinders and threaded taper are most commonly utilized and offer good joints, while the maximum joint efficiency was achieved by the square pin profile and it reached 94% in some investigations.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"59 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141280944","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Removal of Diclofenac from Contaminated Water using Organoclay as Reactive Material 用有机土作为反应材料去除受污染水中的双氯芬酸
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.12.001
Sara M. Saadoon, Alaa Kareem Mohammed, Ziad T. Abd Ali, Israa M. Rashid, Wan Nor Roslam Wan Isahak, M. Rahimnejad
في هذه الدراسة ، تم ازالة المادة الدوائية الديكلوفيناك (Diclofenac) من المياه الملوثة عن طريق الامتزاز على البنتونيت المعدل. تم تغيير البنتونايت من مادة محبة للماء إلى كارهة للماء باستخدام بروميد الأمونيوم ثلاثي ميثيل هيكساديسيل (HTAB). استخدمت التجارب الدفعية لدراسة تأثير عدد من العوامل على كفاءة عملية الامتزاز. هذه العوامل هي: زمن التلامس ، ودرجة الحموضة (pH) للمحلول ، وسرعة الخلط ، وتركيز الملوث الأولي (Co) ، وجرعة المادة الممتزة. تم تحقيق أقصى إزالة للديكلوفيناك (97٪) في الحالات التالية: زمن التلامس 100 دقيقة ، ودرجة الحموضة 7 ، وسرعة الخلط 200 دورة في الدقيقة ، والتركيز الأولي لـ Co 50 جزء في المليون ، والجرعة الممتزة 0.3 جم بينتونيت لكل 100 مل من المحلول الملوث. تم استخدام الفحص المجهري الإلكتروني للماسح الضوئي (SEM) والتحليل الطيفي للأشعة تحت الحمراء لتحويل فورييه (FTIR) لتشخيص صفات المادة الممتزة (البنتونايت المعدل ). وجد ان موديل Langmuir هو الأنسب لتمثيل البيانات التجريبية التي تم الحصول عليها في المختبر. تم دراسة حركية عملية الامتزاز ووجد انها تتمثل بشكل جيد بتفاعل زائف من الدرجة الثانية. كانت عملية الامتزاز ماصة للحرارة وتلقائية ، وفقًا لتحليلات الديناميكا الحرارية.
本研究通过改性膨润土的吸附作用去除受污染水体中的药物双氯芬酸。使用三甲基十六烷基溴化铵(HTAB)将膨润土从亲水性变为疏水性。批量实验用于研究一些因素对吸附过程效率的影响。这些因素包括接触时间、溶液 pH 值、搅拌速度、初始污染物浓度 (Co) 和吸附剂用量。在以下条件下,双氯芬酸的去除率最高(97%):接触时间 100 分钟,pH 值 7,搅拌速度 200 转/分钟,初始 Co 浓度 50 ppm,吸附剂用量为每 100 毫升污染溶液含 0.3 克膨润土。使用扫描电子显微镜(SEM)和傅立叶变换红外光谱(FTIR)对吸附剂(改性膨润土)进行表征。研究发现,Langmuir 模型最适合代表实验室获得的实验数据。对吸附过程的动力学进行了研究,发现它可以很好地用假二阶反应来表示。根据热力学分析,吸附过程是内热和自发的。
{"title":"Removal of Diclofenac from Contaminated Water using Organoclay as Reactive Material","authors":"Sara M. Saadoon, Alaa Kareem Mohammed, Ziad T. Abd Ali, Israa M. Rashid, Wan Nor Roslam Wan Isahak, M. Rahimnejad","doi":"10.22153/kej.2024.12.001","DOIUrl":"https://doi.org/10.22153/kej.2024.12.001","url":null,"abstract":"في هذه الدراسة ، تم ازالة المادة الدوائية الديكلوفيناك (Diclofenac) من المياه الملوثة عن طريق الامتزاز على البنتونيت المعدل. تم تغيير البنتونايت من مادة محبة للماء إلى كارهة للماء باستخدام بروميد الأمونيوم ثلاثي ميثيل هيكساديسيل (HTAB). استخدمت التجارب الدفعية لدراسة تأثير عدد من العوامل على كفاءة عملية الامتزاز. هذه العوامل هي: زمن التلامس ، ودرجة الحموضة (pH) للمحلول ، وسرعة الخلط ، وتركيز الملوث الأولي (Co) ، وجرعة المادة الممتزة. تم تحقيق أقصى إزالة للديكلوفيناك (97٪) في الحالات التالية: زمن التلامس 100 دقيقة ، ودرجة الحموضة 7 ، وسرعة الخلط 200 دورة في الدقيقة ، والتركيز الأولي لـ Co 50 جزء في المليون ، والجرعة الممتزة 0.3 جم بينتونيت لكل 100 مل من المحلول الملوث. تم استخدام الفحص المجهري الإلكتروني للماسح الضوئي (SEM) والتحليل الطيفي للأشعة تحت الحمراء لتحويل فورييه (FTIR) لتشخيص صفات المادة الممتزة (البنتونايت المعدل ). وجد ان موديل Langmuir هو الأنسب لتمثيل البيانات التجريبية التي تم الحصول عليها في المختبر. تم دراسة حركية عملية الامتزاز ووجد انها تتمثل بشكل جيد بتفاعل زائف من الدرجة الثانية. كانت عملية الامتزاز ماصة للحرارة وتلقائية ، وفقًا لتحليلات الديناميكا الحرارية.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"135 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141281812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enhanced Gait Phases Recognition by EMG and Kinematics Information Fusion and a Minimal Recording Setuping Setup 通过肌电图和运动学信息融合及最少的记录设置,增强步态识别能力
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.05.002
R. Mobarak, A. Mengarelli, F. Verdini, S. Fioretti, L. Burattini, A. Tigrini
The limited mobility of lower limb amputees highlights the need for advancements in prosthetic control strategies to restore natural locomotion. This paper proposes an information fusion approach for gait phase recognition using surface electromyography (sEMG) and kinematics data. Time-domain (TD) features were extracted from the myoelectric data and three data-driven models, specifically Support Vector Machine (SVM), K-Nearest Neighbours (KNN), and Artificial Neural Network (ANN), were compared in three different input conditions i.e. sEMG features, hip angle, and their fusion. Gait phase estimation results averaged from 40 healthy participants during normal walking with 10 strides per each demonstrated that the proposed fusion approach has consistently outperformed (p<0.0001) the other two conditions achieving a maximum accuracy of 85.48% with SVM. The findings suggest promising applications in prosthetic motion control and rehabilitative exoskeletons, highlighting the potential for improved user-driven strategies in lower limb prostheses.
下肢截肢者的活动能力有限,这凸显了假肢控制策略的进步以恢复自然运动的必要性。本文提出了一种利用表面肌电图(sEMG)和运动学数据进行步态相位识别的信息融合方法。本文从肌电数据中提取了时域(TD)特征,并比较了三种不同输入条件下的数据驱动模型,即支持向量机(SVM)、K-近邻(KNN)和人工神经网络(ANN)。步态相位估计结果取自 40 名健康参与者正常行走时的平均值,每步 10 个步幅,结果表明所提出的融合方法始终优于其他两种条件(P<0.0001),SVM 的最高准确率为 85.48%。研究结果表明,在假肢运动控制和康复外骨骼中的应用前景广阔,凸显了在下肢假肢中改进用户驱动策略的潜力。
{"title":"Enhanced Gait Phases Recognition by EMG and Kinematics Information Fusion and a Minimal Recording Setuping Setup","authors":"R. Mobarak, A. Mengarelli, F. Verdini, S. Fioretti, L. Burattini, A. Tigrini","doi":"10.22153/kej.2024.05.002","DOIUrl":"https://doi.org/10.22153/kej.2024.05.002","url":null,"abstract":"The limited mobility of lower limb amputees highlights the need for advancements in prosthetic control strategies to restore natural locomotion. This paper proposes an information fusion approach for gait phase recognition using surface electromyography (sEMG) and kinematics data. Time-domain (TD) features were extracted from the myoelectric data and three data-driven models, specifically Support Vector Machine (SVM), K-Nearest Neighbours (KNN), and Artificial Neural Network (ANN), were compared in three different input conditions i.e. sEMG features, hip angle, and their fusion. Gait phase estimation results averaged from 40 healthy participants during normal walking with 10 strides per each demonstrated that the proposed fusion approach has consistently outperformed (p<0.0001) the other two conditions achieving a maximum accuracy of 85.48% with SVM. The findings suggest promising applications in prosthetic motion control and rehabilitative exoskeletons, highlighting the potential for improved user-driven strategies in lower limb prostheses.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"60 17","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141279922","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessment of Foot Deformities in Patient with Knee Osteoarthritis 膝关节骨性关节炎患者足部畸形评估
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.09.001
Ruba Musaid, A. Ghazwan, Waleed A. Al-Saadan
Foot morphology evaluation techniques are commonly used to evaluate foot abnormalities. The foot is essential for keeping the biomechanical performance of the lower extremities. Knee osteoarthritis is a pathological condition that could lead to foot deformities. The major goal of this study was to investigate the prevalence of foot deformity in patients with Knee osteoarthritis. Another goal was to quantify the impact of pain and the severity of osteoarthritis foot morphological changes in Knee osteoarthritis patients.A total of seventy-eight participants took part in this study, including forty-six non-pathological subjects and thirty-two subjects diagnosed with knee osteoarthritis. Foot characteristics were assessed by a podoscope that can automatically estimate foot morphological parameters including Arch Index, Chippaux-Smirak Index, Staheli Index, Weisflog's index, Clarke’s angle and Hallux valgus angle. Numerous foot-related variables have been connected in a direct manner to knee osteoarthritis. Particularly, those who had knee osteoarthritis had substantially higher values for the Arch index (0.29±0.018; P=0.00), Chippaux-Smirak index (0.55±0.5; P=0.00), Staheli index (0.77±0.7; P=0.00), and Weisflog's index (2.7±0.25; P=0.00) than those who did not have this disease. Furthermore, their Clarke's angle and Hallux valgus angle exhibited high values of (30.27±2.7) and (13±1.8), respectively. There were also significant correlations found within the knee osteoarthritis group. There was, for example, a substantial positive correlation between the Arch Index and the Chippaux-Smirak Index (0.767; p=0.00), the Arch Index and the Staheli Index (r=0.35; p=0.04), and the Chippaux-Smirak Index and the Staheli Index (r=0.44; p=0.01). In terms of foot abnormalities, the Midfoot (333.528.6; p=0.00) was more significant than the Rearfoot (604.25±31.2; p=0.85) and Hindfoot (433.3±35.2; p=1.66). With association values of (r=0.4; p=0.02) and (r=0.4; p=0.04), the Arch Index and Chippaux-Smirak Index were both significantly linked with the severity of knee osteoarthritis.Foot abnormalities are substantially more prevalent in persons with Knee osteoarthritis. Collapsed medial longitudinal arch, transverse arch, and hallux valgus are all variables to consider in the management of Knee osteoarthritis. Healthcare providers may target Knee osteoarthritis effects on midfoot morphology with focused therapies. Custom orthotic devices, footwear adjustments, and particular workouts may enhance midfoot stability and alignment. Assessing foot morphology allows healthcare providers to enhance knee osteoarthritis therapy and patient results.
足部形态学评估技术通常用于评估足部异常。足部对保持下肢的生物力学性能至关重要。膝关节骨关节炎是一种可导致足部畸形的病理状态。本研究的主要目的是调查膝关节骨关节炎患者足部畸形的发生率。本研究共有 78 名参与者,包括 46 名非病理受试者和 32 名确诊为膝骨关节炎的受试者。足部特征由足镜进行评估,足镜可自动估算足部形态参数,包括足弓指数、Chippaux-Smirak 指数、Staheli 指数、Weisflog 指数、Clarke 角度和外翻角度。许多与足部相关的变量都与膝关节骨性关节炎有直接联系。尤其是膝关节骨关节炎患者的足弓指数(0.29±0.018;P=0.00)、Chippaux-Smirak指数(0.55±0.5;P=0.00)、Staheli指数(0.77±0.7;P=0.00)和Weisflog指数(2.7±0.25;P=0.00)的数值均远高于未患此病的患者。此外,他们的克拉克角(Clarke's angle)和外翻角(Hallux valgus angle)分别为(30.27±2.7)和(13±1.8)。在膝关节骨性关节炎组中也发现了明显的相关性。例如,足弓指数与 Chippaux-Smirak 指数(0.767;p=0.00)、足弓指数与 Staheli 指数(r=0.35;p=0.04)、Chippaux-Smirak 指数与 Staheli 指数(r=0.44;p=0.01)之间存在显著的正相关。在足部异常方面,中足(333.528.6;p=0.00)比后足(604.25±31.2;p=0.85)和后足(433.3±35.2;p=1.66)更显著。足弓指数和 Chippaux-Smirak 指数与膝关节骨性关节炎严重程度的关联值分别为(r=0.4;p=0.02)和(r=0.4;p=0.04)。内侧纵弓塌陷、横弓和足外翻都是膝关节骨性关节炎治疗中需要考虑的变量。医疗服务提供者可针对膝关节骨关节炎对中足形态的影响采取针对性疗法。定制矫形器、鞋袜调整和特定锻炼可增强中足的稳定性和排列。通过评估足部形态,医疗服务提供者可以提高膝关节骨性关节炎的治疗效果和患者的治疗效果。
{"title":"Assessment of Foot Deformities in Patient with Knee Osteoarthritis","authors":"Ruba Musaid, A. Ghazwan, Waleed A. Al-Saadan","doi":"10.22153/kej.2024.09.001","DOIUrl":"https://doi.org/10.22153/kej.2024.09.001","url":null,"abstract":"Foot morphology evaluation techniques are commonly used to evaluate foot abnormalities. The foot is essential for keeping the biomechanical performance of the lower extremities. Knee osteoarthritis is a pathological condition that could lead to foot deformities. The major goal of this study was to investigate the prevalence of foot deformity in patients with Knee osteoarthritis. Another goal was to quantify the impact of pain and the severity of osteoarthritis foot morphological changes in Knee osteoarthritis patients.A total of seventy-eight participants took part in this study, including forty-six non-pathological subjects and thirty-two subjects diagnosed with knee osteoarthritis. Foot characteristics were assessed by a podoscope that can automatically estimate foot morphological parameters including Arch Index, Chippaux-Smirak Index, Staheli Index, Weisflog's index, Clarke’s angle and Hallux valgus angle. Numerous foot-related variables have been connected in a direct manner to knee osteoarthritis. Particularly, those who had knee osteoarthritis had substantially higher values for the Arch index (0.29±0.018; P=0.00), Chippaux-Smirak index (0.55±0.5; P=0.00), Staheli index (0.77±0.7; P=0.00), and Weisflog's index (2.7±0.25; P=0.00) than those who did not have this disease. Furthermore, their Clarke's angle and Hallux valgus angle exhibited high values of (30.27±2.7) and (13±1.8), respectively. There were also significant correlations found within the knee osteoarthritis group. There was, for example, a substantial positive correlation between the Arch Index and the Chippaux-Smirak Index (0.767; p=0.00), the Arch Index and the Staheli Index (r=0.35; p=0.04), and the Chippaux-Smirak Index and the Staheli Index (r=0.44; p=0.01). In terms of foot abnormalities, the Midfoot (333.528.6; p=0.00) was more significant than the Rearfoot (604.25±31.2; p=0.85) and Hindfoot (433.3±35.2; p=1.66). With association values of (r=0.4; p=0.02) and (r=0.4; p=0.04), the Arch Index and Chippaux-Smirak Index were both significantly linked with the severity of knee osteoarthritis.Foot abnormalities are substantially more prevalent in persons with Knee osteoarthritis. Collapsed medial longitudinal arch, transverse arch, and hallux valgus are all variables to consider in the management of Knee osteoarthritis. Healthcare providers may target Knee osteoarthritis effects on midfoot morphology with focused therapies. Custom orthotic devices, footwear adjustments, and particular workouts may enhance midfoot stability and alignment. Assessing foot morphology allows healthcare providers to enhance knee osteoarthritis therapy and patient results.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"35 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141280194","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
GSM-enabled Wireless Patient Monitoring System Integrating Microcontroller for Managing Vital Signstal signs 集成微控制器的 GSM 无线患者监测系统,用于管理生命体征
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.05.001
Tariq Emad Ali, F. Ali, M. Tejfel, Alwahab Dhulfiqar Zoltán
The primary focus of this project is developing a cutting-edge remote monitoring of patients device for use in an intensive care unit (ICU). The gadget is designed to capture and transmit vital health data from the patient's body, including oxygen saturation levels, heart rate, and temperatures. It is also capable of monitoring a pacemaker. Information is then sent to a remote location after that. The suggested system receives the patient's vital signs and uses them as input on a computer in the nursing room. This transmission is made possible via a transmitter-receiver system consisting of two Arduino kits connected to Bluetooth devices. If any anomalous numbers are discovered as the data is processed, the computer notifies the doctor via the Global System for Mobile Communications (GSM) and the doctor's mobile device. The primary objective of this device is to enable remote monitoring of a patient's medical parameters and prompt alerting of doctors who are situated in remote places of any concerning circumstances. The doctor's mobile device receives the collected values from the workstation. The entire system's structure is implemented using the Visual Basic programming dialect. 
该项目的主要重点是开发一种用于重症监护室(ICU)的尖端远程病人监测设备。该装置可捕捉和传输病人身体的重要健康数据,包括血氧饱和度、心率和体温。它还能监测心脏起搏器。之后,信息会被发送到远程位置。建议系统接收病人的生命体征,并将其输入护理室的计算机。这种传输是通过一个发射器-接收器系统实现的,该系统由两个与蓝牙设备相连的 Arduino 套件组成。如果在处理数据时发现任何异常数字,计算机会通过全球移动通信系统(GSM)和医生的移动设备通知医生。该设备的主要目的是对病人的医疗参数进行远程监控,并及时向远在异地的医生发出警报。医生的移动设备从工作站接收收集到的数值。整个系统的结构使用 Visual Basic 编程方言实现。
{"title":"GSM-enabled Wireless Patient Monitoring System Integrating Microcontroller for Managing Vital Signstal signs","authors":"Tariq Emad Ali, F. Ali, M. Tejfel, Alwahab Dhulfiqar Zoltán","doi":"10.22153/kej.2024.05.001","DOIUrl":"https://doi.org/10.22153/kej.2024.05.001","url":null,"abstract":"The primary focus of this project is developing a cutting-edge remote monitoring of patients device for use in an intensive care unit (ICU). The gadget is designed to capture and transmit vital health data from the patient's body, including oxygen saturation levels, heart rate, and temperatures. It is also capable of monitoring a pacemaker. Information is then sent to a remote location after that. The suggested system receives the patient's vital signs and uses them as input on a computer in the nursing room. This transmission is made possible via a transmitter-receiver system consisting of two Arduino kits connected to Bluetooth devices. If any anomalous numbers are discovered as the data is processed, the computer notifies the doctor via the Global System for Mobile Communications (GSM) and the doctor's mobile device. The primary objective of this device is to enable remote monitoring of a patient's medical parameters and prompt alerting of doctors who are situated in remote places of any concerning circumstances. The doctor's mobile device receives the collected values from the workstation. The entire system's structure is implemented using the Visual Basic programming dialect.\u0000 ","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"14 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141231788","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance Analysis of Different Machine Learning Algorithms for Predictive Maintenance 用于预测性维护的不同机器学习算法的性能分析
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.11.003
Noor A. Mohammed, Osamah F. Abdulateef, Ali H. Hamad, Oday I. Abdullah
يقدم هذا العمل دراسة شاملة عن تقييم أداء خوارزميات التعلم الآلي المختلفة للصيانة التنبؤية في سياق مراقبة حالة محرك التيار المتردد. يركز البحث على سيناريوهات واقعية لتقييم قدرات الخوارزميات المختلفة في التنبؤ بكل من حدوث الأعطال ونوع الفشل المحدد في محركات التيار المتردد. يتم استخدام خمس خوارزميات بارزة للتعلم الآلي، وهي Random Forest (RFC)، وSupport Vector Machine (SVM)، وK-Nearest Neighbors (KNN)، والانحدار اللوجستي (LR)، وXGBoost (XGB)، في هذا العمل. يتضمن التقييم تحليلًا مقارنًا لهذه الخوارزميات بناءً على دقتها التنبؤية، مع مجموعات تدريب بأحجام مختلفة. قبل تطوير النموذج، يتم تطبيق تقنيات معالجة مسبقة صارمة للبيانات لضمان صحة افتراضات النموذج وتحسين الأداء. تتضمن مرحلة المعالجة المسبقة إزالة العينات الغامضة، وترميز الأعمدة الفئوية باستخدام ترميز الملصقات، وقياس الأعمدة. ومن المثير للاهتمام، إعادة النظر في تحديد نقاط البيانات التي تبدو غريبة، مما يكشف عن دورها الأساسي في التقاط التباين الطبيعي لمجموعة البيانات وتعزيز مهام التصنيف. لوحظ أن هذه الميزات المحددة هي مساهمات محورية في النماذج التنبؤية. يوضح العمل أنه بالنسبة للتنبؤ بفشل الآلة وتحديد أنواع الفشل، فإن الخوارزميات تظهر أداءً مشابهًا. الفرق الأساسي يكمن في وقت التدريب. تبرز خوارزمية K-Nearest Neighbors (KNN) باستمرار باعتبارها النموذج الأفضل أداءً لكلتا المهمتين، في حين تؤدي آلة Support Vector Machine (SVM) أداءً دون المستوى الأمثل في مهام التنبؤ بالفشل الثنائي، وXGBoost (XGB) في مهام التنبؤ بالفشل متعددة الفئات، بسبب أوقات استجابتهم. في الختام، تؤكد هذه الورقة على أهمية اختيار نماذج التعلم الآلي المناسبة للصيانة التنبؤية، مع الأخذ في الاعتبار المفاضلة بين الدقة ووقت التدريب. توفر النتائج رؤى قيمة للشركات التي تهدف إلى تنفيذ استراتيجيات صيانة تنبؤية تتسم بالكفاءة والفعالية، مع ظهور KNN كخيار مثالي للتطبيق السريع.
本研究介绍了在交流电机状态监测方面对用于预测性维护的不同机器学习算法进行性能评估的综合研究。研究侧重于现实场景,以评估不同算法在预测交流电机故障发生和具体故障类型方面的能力。本研究采用了五种著名的机器学习算法,即随机森林 (RFC)、支持向量机 (SVM)、K-最近邻 (KNN)、逻辑回归 (LR) 和 XGBoost (XGB)。评估包括根据这些算法的预测准确性,使用不同规模的训练集对其进行比较分析。在模型开发之前,我们采用了严格的数据预处理技术,以确保模型假设的正确性和性能的最优化。预处理阶段包括去除模棱两可的样本,使用标签编码对分类列进行编码,以及对列进行测量。有趣的是,对看似异常值的数据点的识别被重新审视,揭示了它们在捕捉数据集的自然差异和增强分类任务方面的重要作用。据观察,这些已识别的特征对预测模型的贡献举足轻重。研究结果表明,在机器故障预测和故障类型识别方面,这些算法表现出相似的性能。主要区别在于训练时间。K-Nearest Neighbors (KNN) 算法一直是这两项任务中性能最好的模型,而支持向量机 (SVM) 在二进制故障预测任务中的性能不理想,XGBoost (XGB) 在多类故障预测任务中的性能不理想,原因在于它们的响应时间。总之,本文强调了为预测性维护选择合适的机器学习模型的重要性,同时考虑了准确性和训练时间之间的权衡。研究结果为旨在实施高效预测性维护策略的组织提供了宝贵的见解,其中 KNN 是快速实施的理想选择。
{"title":"Performance Analysis of Different Machine Learning Algorithms for Predictive Maintenance","authors":"Noor A. Mohammed, Osamah F. Abdulateef, Ali H. Hamad, Oday I. Abdullah","doi":"10.22153/kej.2024.11.003","DOIUrl":"https://doi.org/10.22153/kej.2024.11.003","url":null,"abstract":"يقدم هذا العمل دراسة شاملة عن تقييم أداء خوارزميات التعلم الآلي المختلفة للصيانة التنبؤية في سياق مراقبة حالة محرك التيار المتردد. يركز البحث على سيناريوهات واقعية لتقييم قدرات الخوارزميات المختلفة في التنبؤ بكل من حدوث الأعطال ونوع الفشل المحدد في محركات التيار المتردد. يتم استخدام خمس خوارزميات بارزة للتعلم الآلي، وهي Random Forest (RFC)، وSupport Vector Machine (SVM)، وK-Nearest Neighbors (KNN)، والانحدار اللوجستي (LR)، وXGBoost (XGB)، في هذا العمل. يتضمن التقييم تحليلًا مقارنًا لهذه الخوارزميات بناءً على دقتها التنبؤية، مع مجموعات تدريب بأحجام مختلفة. قبل تطوير النموذج، يتم تطبيق تقنيات معالجة مسبقة صارمة للبيانات لضمان صحة افتراضات النموذج وتحسين الأداء. تتضمن مرحلة المعالجة المسبقة إزالة العينات الغامضة، وترميز الأعمدة الفئوية باستخدام ترميز الملصقات، وقياس الأعمدة. ومن المثير للاهتمام، إعادة النظر في تحديد نقاط البيانات التي تبدو غريبة، مما يكشف عن دورها الأساسي في التقاط التباين الطبيعي لمجموعة البيانات وتعزيز مهام التصنيف. لوحظ أن هذه الميزات المحددة هي مساهمات محورية في النماذج التنبؤية. يوضح العمل أنه بالنسبة للتنبؤ بفشل الآلة وتحديد أنواع الفشل، فإن الخوارزميات تظهر أداءً مشابهًا. الفرق الأساسي يكمن في وقت التدريب. تبرز خوارزمية K-Nearest Neighbors (KNN) باستمرار باعتبارها النموذج الأفضل أداءً لكلتا المهمتين، في حين تؤدي آلة Support Vector Machine (SVM) أداءً دون المستوى الأمثل في مهام التنبؤ بالفشل الثنائي، وXGBoost (XGB) في مهام التنبؤ بالفشل متعددة الفئات، بسبب أوقات استجابتهم. في الختام، تؤكد هذه الورقة على أهمية اختيار نماذج التعلم الآلي المناسبة للصيانة التنبؤية، مع الأخذ في الاعتبار المفاضلة بين الدقة ووقت التدريب. توفر النتائج رؤى قيمة للشركات التي تهدف إلى تنفيذ استراتيجيات صيانة تنبؤية تتسم بالكفاءة والفعالية، مع ظهور KNN كخيار مثالي للتطبيق السريع.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"51 36","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141232063","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Finite Element Analysis of New Designed Intercalary Prosthesis Implant (Ulna Bone) 新设计的椎间假体植入体(乌尔骨)的有限元分析
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.01.001
Sadeer Anwer Mustafa, Ahmed Z. M. Shammari, Wmieth A. J. Augla, M. N. Mohammed
   Implantation via an intercalary prosthetic method is a reliable solution for reconstructing a long defect in bones that has been damaged by severe disease or accidents. In the current study, using data from computed tomography (CT) scans, a novel costumed intercalary prosthesis design has been created. To achieve this purpose, the CT scan data of a patient in (DICOM) file format was converted into computer-aided design models and saved in stereolithography (STL) format using the 3D slicer (5.0.3) software. The STL files were loaded into Meshmixer software to design the models of the intercalary prosthesis. Finite element analysis (FEA) was applied to validate the strength of the prosthesis with impact, tensile testing, and torsional testing. According to the results of the impact tests, the highest recorded deformation was 8.8485e-002 m in the area where the implant body interfaces with the bone intramedullary canal, due to the high-stress (Von Mises Stress) value of 3.78 E9 PA. In the torsional loaded the highest deformation recorded was 1.3871e-008 m when the Von Mises stress reached 49006 PA,  and with the application of the tensile test the largest deformation measured as 1.0458e-006 m at maximum Von Mises stress seen was recorded as 6.6012e+006 PA which caused that. A solid rod of Ti6Al4V alloy was selected. Finally, the analysis proved that the implant had enhanced mechanical properties. Based on the findings, it can be inferred that the prosthesis was successfully implanted, and a satisfactory result was obtained by using this design method.
通过椎间假体植入的方法是重建因严重疾病或事故而受损的长骨缺损的可靠解决方案。在当前的研究中,利用计算机断层扫描(CT)数据,设计出了一种新颖的仿真椎间假体。为此,使用 3D slicer (5.0.3) 软件将 DICOM 文件格式的患者 CT 扫描数据转换为计算机辅助设计模型,并保存为立体光刻 (STL) 格式。STL 文件被载入 Meshmixer 软件,用于设计椎间假体模型。应用有限元分析(FEA)通过冲击、拉伸测试和扭转测试来验证假体的强度。根据冲击试验的结果,由于高应力(Von Mises Stress)值为 3.78 E9 PA,在假体本体与骨髓内管交接处记录到的最大变形为 8.8485e-002 m。在扭转加载中,当 Von Mises 应力达到 49006 PA 时,记录到的最大变形量为 1.3871e-008 m,而在拉伸试验中,当 Von Mises 应力达到最大值 6.6012e+006 PA 时,测量到的最大变形量为 1.0458e-006 m。因此,我们选择了 Ti6Al4V 合金实心棒。最后,分析表明该植入物具有更强的机械性能。根据分析结果,可以推断该假体已成功植入,并通过这种设计方法获得了令人满意的结果。
{"title":"Finite Element Analysis of New Designed Intercalary Prosthesis Implant (Ulna Bone)","authors":"Sadeer Anwer Mustafa, Ahmed Z. M. Shammari, Wmieth A. J. Augla, M. N. Mohammed","doi":"10.22153/kej.2024.01.001","DOIUrl":"https://doi.org/10.22153/kej.2024.01.001","url":null,"abstract":"   \u0000Implantation via an intercalary prosthetic method is a reliable solution for reconstructing a long defect in bones that has been damaged by severe disease or accidents. In the current study, using data from computed tomography (CT) scans, a novel costumed intercalary prosthesis design has been created. To achieve this purpose, the CT scan data of a patient in (DICOM) file format was converted into computer-aided design models and saved in stereolithography (STL) format using the 3D slicer (5.0.3) software. The STL files were loaded into Meshmixer software to design the models of the intercalary prosthesis. Finite element analysis (FEA) was applied to validate the strength of the prosthesis with impact, tensile testing, and torsional testing. According to the results of the impact tests, the highest recorded deformation was 8.8485e-002 m in the area where the implant body interfaces with the bone intramedullary canal, due to the high-stress (Von Mises Stress) value of 3.78 E9 PA. In the torsional loaded the highest deformation recorded was 1.3871e-008 m when the Von Mises stress reached 49006 PA,  and with the application of the tensile test the largest deformation measured as 1.0458e-006 m at maximum Von Mises stress seen was recorded as 6.6012e+006 PA which caused that. A solid rod of Ti6Al4V alloy was selected. Finally, the analysis proved that the implant had enhanced mechanical properties. Based on the findings, it can be inferred that the prosthesis was successfully implanted, and a satisfactory result was obtained by using this design method.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"143 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141281318","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modeling and Simulation of Hydraulic Proportional Control Valves with Different Types of Controllers s 使用不同类型控制器的液压比例控制阀的建模与仿真 s
Pub Date : 2024-06-01 DOI: 10.22153/kej.2024.03.001
Sarah M. Rashid, Maher Yahya Salloom, N. H. B. Jemily, A. H.
تهدف هذه الدراسة إلى تصميم وتطويرمنصة ذاتية التوازن. تستخدم في العديد من التطبيقات الصناعية التي تحتاج الى استواء سطح المنصة لضمان عملها بكفاءة عالية. تم تصميم وتنفيذ منصة تتكون من اسطوانتين هيدروليكية يتم التحكم بهما بواسطة صمامين سيطرة هيدروليكية تناسبية. يتضمن تصميم النظام الهيدروليكي الافتراضي تحليل النظام واشتقاقه. وبعد ذلك، تم تقييم أداء النظام من خلال تحديد النهج الأمثل للحصول على البيانات kp وki و  kd. من خلال استخدام محاكاة MATLAB ، تم إجراء فحص لتحسين وحدة التحكم PID للخوارزمية الجينية (GA) الحالية وخوارزمية تحسين سرب الجسيمات (PSO). تشير النتائج إلى أن خوارزمية التحكم PID للخوارزمية الجينية (GA) تتفوق على في تحسين أداء النظام من خوارزمية تحسين سرب الجسيمات (PSO) . كان معيار التحكم في الأخطاء الذي تم اختياره لنظام التحكم في منصة التوازن الذاتي هو نوع الخطأ المطلق للوقت المتكامل . (ITAE). يُظهر النظام معدلًا محسّنًا للتقارب.
本研究旨在设计和开发一种自平衡平台。在许多工业应用中,需要对平台表面进行平整处理,以确保其有效工作。研究设计并实现了一个由两个液压缸组成的平台,液压缸由两个比例液压控制阀控制。虚拟液压系统的设计包括系统分析和推导。随后,通过确定获取数据 kp、ki 和 kd 的最佳方法,对系统性能进行了评估。通过使用 MATLAB 仿真,对现有遗传算法(GA)和粒子群优化算法(PSO)的 PID 控制器优化进行了检查。结果表明,在提高系统性能方面,遗传算法(GA)的 PID 控制算法优于粒子群优化(PSO)算法。自平衡平台控制系统选择的误差控制标准是综合时间绝对误差类型(ITAE)。(ITAE)。该系统的收敛速度有所提高。
{"title":"Modeling and Simulation of Hydraulic Proportional Control Valves with Different Types of Controllers s","authors":"Sarah M. Rashid, Maher Yahya Salloom, N. H. B. Jemily, A. H.","doi":"10.22153/kej.2024.03.001","DOIUrl":"https://doi.org/10.22153/kej.2024.03.001","url":null,"abstract":"تهدف هذه الدراسة إلى تصميم وتطويرمنصة ذاتية التوازن. تستخدم في العديد من التطبيقات الصناعية التي تحتاج الى استواء سطح المنصة لضمان عملها بكفاءة عالية. تم تصميم وتنفيذ منصة تتكون من اسطوانتين هيدروليكية يتم التحكم بهما بواسطة صمامين سيطرة هيدروليكية تناسبية. يتضمن تصميم النظام الهيدروليكي الافتراضي تحليل النظام واشتقاقه. وبعد ذلك، تم تقييم أداء النظام من خلال تحديد النهج الأمثل للحصول على البيانات kp وki و  kd. من خلال استخدام محاكاة MATLAB ، تم إجراء فحص لتحسين وحدة التحكم PID للخوارزمية الجينية (GA) الحالية وخوارزمية تحسين سرب الجسيمات (PSO). تشير النتائج إلى أن خوارزمية التحكم PID للخوارزمية الجينية (GA) تتفوق على في تحسين أداء النظام من خوارزمية تحسين سرب الجسيمات (PSO) . كان معيار التحكم في الأخطاء الذي تم اختياره لنظام التحكم في منصة التوازن الذاتي هو نوع الخطأ المطلق للوقت المتكامل . (ITAE). يُظهر النظام معدلًا محسّنًا للتقارب.","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"65 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141278449","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Karnaugh Maps Adaptability to Implement Multiple-Actuator Pneumatic Circuits 卡诺夫图实现多执行器气动回路的适应性
Pub Date : 2024-03-01 DOI: 10.22153/kej.2024.10.003
ALZahraa Nather, M. Salloom, Amir Azizi, Sahala Siallagan
  
{"title":"Karnaugh Maps Adaptability to Implement Multiple-Actuator Pneumatic Circuits","authors":"ALZahraa Nather, M. Salloom, Amir Azizi, Sahala Siallagan","doi":"10.22153/kej.2024.10.003","DOIUrl":"https://doi.org/10.22153/kej.2024.10.003","url":null,"abstract":"  ","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"60 25","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140085236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quantitative Analysis of Isometric Ankle Torque and Muscle Activity during Dorsiflexion and Plantarflexion 外翻和跖屈时踝关节等长扭矩和肌肉活动的定量分析
Pub Date : 2024-03-01 DOI: 10.22153/kej.2024.10.002
Osamah A. A. Almasiri, Ali K. Buniya, Hussam K Abdul-Ameer
الخلاصة تعتبر حركات القدم والكاحل ، مثل الثني الظهري (رفع القدم لأعلى) والثني الأخمصي (توجيه القدم لأسفل) ، أساسية لمجموعة من الأنشطة اليومية مثل المشي والجري والحفاظ على التوازن. حيث تعتمد الميكانيكا الحيوية المناسبة في هذه الحركات على تنسيق عالي بين لكل عضلة حول مفصل الكاحل. Save translation في هذا البحث تم التحقق من العلاقة بين عزم دوران الكاحل متساوي القياس والنشاط العضلي لعظلة الظنبوب الأمامية  وعضلة الساق البطنية أثناء الثني الظهري والثني الأخمصي. اشتملت الدراسة على ثمانية أشخاص أصحاء ، وتم استخدام قياس النشاط الكهربي للعضلة السطحي (sEMG) لتسجيل نشاط العضلات. أظهرت النتائج أن عزم الكاحل كان أعلى أثناء الانثناء الأخمصي مقارنة بالانثناء الظهري. علاوة على ذلك ، أظهر عضلة الظنبوب الأمامية نشاطًا عضليًا أكبر أثناء الانثناء الظهري ، بينما أظهر عضلة الساق البطنية نشاطًا أعلى أثناء الثني الأخمصي. تلقي هذه النتائج الضوء على الميكانيكا الحيوية للكاحل ولما لها من آثار محتملة على التدخلات السريرية واستراتيجيات إعادة تأهيل القدم. هذه الدراسة تعطي تبريرا كافية لإجراء مزيد من البحث حول أدوار عضلات الثني الأخرى في حركات الكاحل للحصول على رؤى شاملة حول تنشيط العضلات وعزم دوران الكاحل متساوي القياس.      
摘要 脚和踝关节的运动,如背屈(将脚抬起)和跖屈(将脚指向下方),对于行走、跑步和保持平衡等一系列日常活动至关重要。这些动作的正确生物力学依赖于踝关节周围每块肌肉之间的高度协调。这项研究调查了等长踝关节扭矩与胫骨前肌和腹侧腓肠肌在背屈和跖屈时的肌肉活动之间的关系。研究涉及八名健康受试者,使用表面肌电图(sEMG)记录肌肉活动。结果显示,与背屈时相比,跖屈时的踝关节力矩更大。此外,胫骨前肌在背屈时表现出更大的肌肉活动,而腓肠肌腹肌在跖屈时表现出更大的肌肉活动。这些发现揭示了踝关节的生物力学,对临床干预和足部康复策略具有潜在的影响。这项研究为进一步研究其他屈肌在踝关节运动中的作用提供了充分的理由,以便全面了解肌肉激活和踝关节等长扭矩。
{"title":"Quantitative Analysis of Isometric Ankle Torque and Muscle Activity during Dorsiflexion and Plantarflexion","authors":"Osamah A. A. Almasiri, Ali K. Buniya, Hussam K Abdul-Ameer","doi":"10.22153/kej.2024.10.002","DOIUrl":"https://doi.org/10.22153/kej.2024.10.002","url":null,"abstract":"الخلاصة \u0000تعتبر حركات القدم والكاحل ، مثل الثني الظهري (رفع القدم لأعلى) والثني الأخمصي (توجيه القدم لأسفل) ، أساسية لمجموعة من الأنشطة اليومية مثل المشي والجري والحفاظ على التوازن. حيث تعتمد الميكانيكا الحيوية المناسبة في هذه الحركات على تنسيق عالي بين لكل عضلة حول مفصل الكاحل. \u0000Save translation \u0000في هذا البحث تم التحقق من العلاقة بين عزم دوران الكاحل متساوي القياس والنشاط العضلي لعظلة الظنبوب الأمامية  وعضلة الساق البطنية أثناء الثني الظهري والثني الأخمصي. اشتملت الدراسة على ثمانية أشخاص أصحاء ، وتم استخدام قياس النشاط الكهربي للعضلة السطحي (sEMG) لتسجيل نشاط العضلات. أظهرت النتائج أن عزم الكاحل كان أعلى أثناء الانثناء الأخمصي مقارنة بالانثناء الظهري. علاوة على ذلك ، أظهر عضلة الظنبوب الأمامية نشاطًا عضليًا أكبر أثناء الانثناء الظهري ، بينما أظهر عضلة الساق البطنية نشاطًا أعلى أثناء الثني الأخمصي. تلقي هذه النتائج الضوء على الميكانيكا الحيوية للكاحل ولما لها من آثار محتملة على التدخلات السريرية واستراتيجيات إعادة تأهيل القدم. هذه الدراسة تعطي تبريرا كافية لإجراء مزيد من البحث حول أدوار عضلات الثني الأخرى في حركات الكاحل للحصول على رؤى شاملة حول تنشيط العضلات وعزم دوران الكاحل متساوي القياس. \u0000  \u0000  \u0000 ","PeriodicalId":7637,"journal":{"name":"Al-Khwarizmi Engineering Journal","volume":"119 38","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140089437","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Al-Khwarizmi Engineering Journal
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1