首页 > 最新文献

Zeitschrift fur medizinische Laboratoriumsdiagnostik最新文献

英文 中文
[Lipoprotein (a)--is it a connecting link between fat metabolism and coagulation?]. [脂蛋白(a)——它是脂肪代谢和凝血之间的连接纽带吗?]
W F Riesen
{"title":"[Lipoprotein (a)--is it a connecting link between fat metabolism and coagulation?].","authors":"W F Riesen","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"147-9"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12993520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Measruement of capillary blood using the Coulter S Plus VI, the Coulter T660 and the Coulter T890]. [使用Coulter S Plus VI、Coulter T660和Coulter T890测量毛细血管血液]。
C Ruby
{"title":"[Measruement of capillary blood using the Coulter S Plus VI, the Coulter T660 and the Coulter T890].","authors":"C Ruby","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"217-9"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13057581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Visual test evaluation of the results for the semiquantitative determination of cystine in urine using the nickel/dithionite (Ni2+/S2O42-) test]. [用镍/二亚铁酸盐(Ni2+/S2O42-)试验半定量测定尿中胱氨酸的目测评价]。
O Kilian, W Berg

The Ni2+/S2O4(2-)-test makes semiquantitative assessment of cystine concentration in urine possible. The reaction principle of the method is based on the formation of a nickel/cysteine/sulfide complex of brown colour. Visual test evaluation is done by classifying the colour intensity of the sample/reagent mixture according to an exact colour shade. Each colour shade on a colour reference table is correlated to a certain range of cystine concentration. Cystine determination is described in detail for two ranges (0.60 and 1.25 mmol/l).

Ni2+/S2O4(2-)试验使半定量评估尿中胱氨酸浓度成为可能。该方法的反应原理是基于形成棕色的镍/半胱氨酸/硫化物络合物。视觉测试评估是通过根据确切的色度对样品/试剂混合物的颜色强度进行分类来完成的。颜色参考表上的每种色度都与一定范围内的胱氨酸浓度相关。胱氨酸的测定详细描述了两个范围(0.60和1.25 mmol/l)。
{"title":"[Visual test evaluation of the results for the semiquantitative determination of cystine in urine using the nickel/dithionite (Ni2+/S2O42-) test].","authors":"O Kilian,&nbsp;W Berg","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The Ni2+/S2O4(2-)-test makes semiquantitative assessment of cystine concentration in urine possible. The reaction principle of the method is based on the formation of a nickel/cysteine/sulfide complex of brown colour. Visual test evaluation is done by classifying the colour intensity of the sample/reagent mixture according to an exact colour shade. Each colour shade on a colour reference table is correlated to a certain range of cystine concentration. Cystine determination is described in detail for two ranges (0.60 and 1.25 mmol/l).</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"50-6"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224456","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Protein adsorption at the tips from synthetic polymers as the cause of incorrect titer analysis of interferons in antiviral bioassays]. [抗病毒生物测定中干扰素滴度分析不正确的原因是合成聚合物尖端处的蛋白质吸附]。
M Tonew, E Ohme, D Gerlach, R H Wondraczek

The determination of the biological activity of interferons are carried out on the basis of the inhibition of the cytopathic effect of vesicular stomatitis virus on MDBK cells. Using microtiter-plates and tips made of synthetic polymers incorrect data may be observed due to the adsorption of the protein interferon to the tips and, thus, carryover of activity. The following recommendations may help to avoid this kind of mistakes: 1. Generally changing of the tips, at least for the highest concentrations. 2. Reduction of high initial activities by an appropriate pre-dilution. 3. Addition of the detergent Triton X 100 in concentrations between 50 to 100 mg/l to the dilution media for interferon.

干扰素生物活性的测定是在抑制水疱性口炎病毒对MDBK细胞的细胞病变作用的基础上进行的。使用由合成聚合物制成的微量滴度板和针尖可能会观察到不正确的数据,这是由于干扰素蛋白在针尖上的吸附,从而导致活性的延续。下面的建议可能有助于避免这类错误:通常情况下,针尖会发生变化,至少在浓度最高的情况下是这样。2. 通过适当的预稀释来降低高的初始活性。3.在干扰素稀释培养基中加入浓度在50至100 mg/l之间的洗涤剂Triton X 100。
{"title":"[Protein adsorption at the tips from synthetic polymers as the cause of incorrect titer analysis of interferons in antiviral bioassays].","authors":"M Tonew,&nbsp;E Ohme,&nbsp;D Gerlach,&nbsp;R H Wondraczek","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The determination of the biological activity of interferons are carried out on the basis of the inhibition of the cytopathic effect of vesicular stomatitis virus on MDBK cells. Using microtiter-plates and tips made of synthetic polymers incorrect data may be observed due to the adsorption of the protein interferon to the tips and, thus, carryover of activity. The following recommendations may help to avoid this kind of mistakes: 1. Generally changing of the tips, at least for the highest concentrations. 2. Reduction of high initial activities by an appropriate pre-dilution. 3. Addition of the detergent Triton X 100 in concentrations between 50 to 100 mg/l to the dilution media for interferon.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 2","pages":"108-13"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12814644","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Evaluation of methods for the analysis of low insulin concentrations in serum]. [血清低胰岛素浓度分析方法评价]。
K Jung, S Klotzek, B D Schulze

Three methods of the determination of insulin in serum were optimized in order to determine low concentrations of this analyte reliably (Method I: enzymatic after acidic hydrolysis of inulin; Method II: by anthrone/sulfuric acid reagent; Method III: by cysteine/tryptophan reagent). The interfering reaction of glucose in the methods I and II was avoided by the preincubation of samples with glucose oxidase/catalase reagent. The detection limit of all three methods was below 5 mg/l and the within-run precision amounted to values below 5%. Method I and II gave identical results. In comparison with these two methods, method III resulted in inulin values by about 8% lower, because inulin, depending on the lot used, contained alkali-labile fractions which were destroyed during the sample preparation. Method II is recommended for routine measurements because of its an analytical reliability and its cost-effectiveness.

为了可靠地测定低浓度胰岛素,对血清中胰岛素的3种测定方法进行了优化(方法一:用酶法将胰岛素酸水解;方法二:用蒽酮/硫酸试剂;方法三:采用半胱氨酸/色氨酸试剂)。采用葡萄糖氧化酶/过氧化氢酶试剂对样品进行预孵育,避免了方法1和方法2中葡萄糖的干扰反应。3种方法的检出限均在5 mg/l以下,运行内精密度均在5%以下。方法1和方法2的结果相同。与这两种方法相比,方法III的菊粉值降低了约8%,因为根据所用批次的不同,菊粉中含有碱不稳定组分,这些组分在样品制备过程中被破坏。方法二因其分析可靠性和成本效益而被推荐用于常规测量。
{"title":"[Evaluation of methods for the analysis of low insulin concentrations in serum].","authors":"K Jung,&nbsp;S Klotzek,&nbsp;B D Schulze","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Three methods of the determination of insulin in serum were optimized in order to determine low concentrations of this analyte reliably (Method I: enzymatic after acidic hydrolysis of inulin; Method II: by anthrone/sulfuric acid reagent; Method III: by cysteine/tryptophan reagent). The interfering reaction of glucose in the methods I and II was avoided by the preincubation of samples with glucose oxidase/catalase reagent. The detection limit of all three methods was below 5 mg/l and the within-run precision amounted to values below 5%. Method I and II gave identical results. In comparison with these two methods, method III resulted in inulin values by about 8% lower, because inulin, depending on the lot used, contained alkali-labile fractions which were destroyed during the sample preparation. Method II is recommended for routine measurements because of its an analytical reliability and its cost-effectiveness.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"23-9"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Pathobiogenetic concept of Duchenne muscular dystrophy following the discovery of dystrophin as the deficient protein]. 【发现肌营养不良蛋白为缺陷蛋白后,杜氏肌营养不良的发病机制概念】。
D Kunze, B Rüstow
{"title":"[Pathobiogenetic concept of Duchenne muscular dystrophy following the discovery of dystrophin as the deficient protein].","authors":"D Kunze,&nbsp;B Rüstow","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"141-6"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13056872","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Agent-conditioned influence on carbohydrate metabolism and energy state in liver and lung of rats in endotoxic shock]. [内毒素休克大鼠肝、肺碳水化合物代谢及能量状态的影响]。
S Kopprasch, K Kociok, M Kohl, D W Scheuch

The pretreatment of rats with the substance LPH and LXU caused decrease of lethality in endotoxin shock and suppression of the following changes 6 hours post endotoxin: Increase of plasma ICDH activity, decrease in platelet count, decrease of the hepatic energy state and increase of the ATP content in the lung. The catabolic glucose metabolism during endotoxin shock was not influenced by LPH and LXU administration.

LPH和LXU物质预处理大鼠可降低内毒素休克致死率,抑制内毒素后6 h血浆ICDH活性升高、血小板计数降低、肝脏能量状态降低、肺内ATP含量升高。内毒素休克时的糖代谢不受LPH和LXU的影响。
{"title":"[Agent-conditioned influence on carbohydrate metabolism and energy state in liver and lung of rats in endotoxic shock].","authors":"S Kopprasch,&nbsp;K Kociok,&nbsp;M Kohl,&nbsp;D W Scheuch","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The pretreatment of rats with the substance LPH and LXU caused decrease of lethality in endotoxin shock and suppression of the following changes 6 hours post endotoxin: Increase of plasma ICDH activity, decrease in platelet count, decrease of the hepatic energy state and increase of the ATP content in the lung. The catabolic glucose metabolism during endotoxin shock was not influenced by LPH and LXU administration.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"167-72"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13056876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Application of the monodimensional electrophoresis for the separation of glycosaminoglycans on Cellogel cellulose acetate strip. 一维电泳在醋酸纤维素条上分离糖胺聚糖的应用。
D Juretić, J Bingulac-Popović, K Lipovac, I Ligutić

A monodimensional electrophoretic method for the separation of glycosaminoglycans on Titan III Zip Zone cellulose acetate plate based on their different electrophoretic mobilities in barium acetate and different solubilities in ethanol was applied to the Chemetron electrophoretic equipment. Improved timing of individual steps of electrophoretic run, additional cooling and pressure must be introduced for optimal separation of glycosaminoglycans mixture (dermatan sulphate, heparan sulphate, hyaluronic acid, chondroitin-4-sulphate, chondroitin-6-sulphate and keratan sulphate) resulting in five well separated sharp bands. By all these changes in the original procedure of Hopwood and Harrison, the separation of chondroitin-4-sulphate and chondroitin-6-sulphate was not achieved. The modified procedure on Cellogel strip is suitable for the screening of mucopolysaccharidoses.

基于糖胺聚糖在乙酸钡中不同的电泳迁移率和在乙醇中的不同溶解度,建立了一种在Titan III Zip Zone醋酸纤维素板上分离糖胺聚糖的一维电泳方法。改进电泳运行的单个步骤的时间,额外的冷却和压力必须引入糖胺聚糖混合物的最佳分离(硫酸皮聚糖,硫酸肝素,透明质酸,硫酸软骨素-4,硫酸软骨素-6和硫酸角蛋白),导致五个分离良好的尖锐带。由于Hopwood和Harrison对原程序的这些改变,未能实现4-硫酸软骨素和6-硫酸软骨素的分离。改进后的凝胶条法适用于粘多糖的筛选。
{"title":"Application of the monodimensional electrophoresis for the separation of glycosaminoglycans on Cellogel cellulose acetate strip.","authors":"D Juretić,&nbsp;J Bingulac-Popović,&nbsp;K Lipovac,&nbsp;I Ligutić","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A monodimensional electrophoretic method for the separation of glycosaminoglycans on Titan III Zip Zone cellulose acetate plate based on their different electrophoretic mobilities in barium acetate and different solubilities in ethanol was applied to the Chemetron electrophoretic equipment. Improved timing of individual steps of electrophoretic run, additional cooling and pressure must be introduced for optimal separation of glycosaminoglycans mixture (dermatan sulphate, heparan sulphate, hyaluronic acid, chondroitin-4-sulphate, chondroitin-6-sulphate and keratan sulphate) resulting in five well separated sharp bands. By all these changes in the original procedure of Hopwood and Harrison, the separation of chondroitin-4-sulphate and chondroitin-6-sulphate was not achieved. The modified procedure on Cellogel strip is suitable for the screening of mucopolysaccharidoses.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"180-7"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13056878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[An average variation for glucose determination using the ECA 20]. [使用ECA测定葡萄糖的平均变化]。
I Gödicke, B Brys, W Gödicke
{"title":"[An average variation for glucose determination using the ECA 20].","authors":"I Gödicke,&nbsp;B Brys,&nbsp;W Gödicke","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"213-6"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13057580","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Immunoturbidimetric determination of C-3 components of complement systems using nonlinear calibration]. [免疫比浊法测定补体系统中C-3组分的非线性校准]。
J Rohácek, V Semrád, E Klierová, M Zápotocná

A method for the immunoturbidimetric analysis of the C-3-component in the complement system was elaborated by means of the antiserum Q-SwAHu/C3 USOL (SEVAG) Praha. A diluted human control serum USOL (SEVAG) Praha with declared values of plasma proteins was applied as a standard solution. The relation between concentration and absorption in an eight step calibration series is well described by a parabola of the 2nd degree. The precision in series and the accuracy of the method are mentioned. The proposed technique is in a relatively good correlation with the radial immunodiffusion according to MANCINI.

采用抗血清Q-SwAHu/C3 USOL (SEVAG) Praha,建立了补体系统c -3组分的免疫比浊分析方法。稀释的人对照血清USOL (SEVAG) Praha作为标准溶液,并声明血浆蛋白值。用二阶抛物线很好地描述了八步校准系列中浓度与吸收之间的关系。提出了该方法的序列精度和精度。根据MANCINI,该技术与径向免疫扩散具有较好的相关性。
{"title":"[Immunoturbidimetric determination of C-3 components of complement systems using nonlinear calibration].","authors":"J Rohácek,&nbsp;V Semrád,&nbsp;E Klierová,&nbsp;M Zápotocná","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A method for the immunoturbidimetric analysis of the C-3-component in the complement system was elaborated by means of the antiserum Q-SwAHu/C3 USOL (SEVAG) Praha. A diluted human control serum USOL (SEVAG) Praha with declared values of plasma proteins was applied as a standard solution. The relation between concentration and absorption in an eight step calibration series is well described by a parabola of the 2nd degree. The precision in series and the accuracy of the method are mentioned. The proposed technique is in a relatively good correlation with the radial immunodiffusion according to MANCINI.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"15-8"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13066897","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Zeitschrift fur medizinische Laboratoriumsdiagnostik
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1