[Examinations of the analytic reliability of N-acetylneuraminic acid determinations according to the pharmacopoeia of the GDR]. [根据德国药典检验n -乙酰神经氨酸测定的分析可靠性]。
G Bollmann, B Schulz

A further investigation of the Arzneibuch (Diagnostic Laboratory Methods) GDR-method for the estimation of N-acetylneuraminic acid was performed. By this was found, that the formation of the dye complex is not still finished after 15 minutes and the reaction product shows an exponential decomposition. The decomposition rate was much greater in the reaction medium than in n-amyl alcohol. By increasing the ferric (III)-chloride concentration the specificity of the method could be essentially improved. With the fivefold ferric (III)-chloride concentration the physiological concentrations of the protein bound monosaccharides of the serum changed the accuracy of the measuring results by less than or equal to 2.0%.

进一步研究了Arzneibuch(诊断实验室方法)gdr法对n -乙酰神经氨酸的估计。由此发现,15分钟后染料络合物的形成仍未完成,反应产物呈指数分解。在反应介质中的分解速率远高于在正戊醇中的分解速率。通过提高三氯化铁的浓度,可以从根本上提高方法的特异性。在五倍氯化铁浓度下,血清蛋白结合单糖的生理浓度对测定结果的准确度的影响小于等于2.0%。
{"title":"[Examinations of the analytic reliability of N-acetylneuraminic acid determinations according to the pharmacopoeia of the GDR].","authors":"G Bollmann,&nbsp;B Schulz","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A further investigation of the Arzneibuch (Diagnostic Laboratory Methods) GDR-method for the estimation of N-acetylneuraminic acid was performed. By this was found, that the formation of the dye complex is not still finished after 15 minutes and the reaction product shows an exponential decomposition. The decomposition rate was much greater in the reaction medium than in n-amyl alcohol. By increasing the ferric (III)-chloride concentration the specificity of the method could be essentially improved. With the fivefold ferric (III)-chloride concentration the physiological concentrations of the protein bound monosaccharides of the serum changed the accuracy of the measuring results by less than or equal to 2.0%.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 2","pages":"101-7"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Determination of thyroglobulin autoantibodies using enzyme immunoassay, radioimmunoassay and passive hemagglutination]. [用酶免疫分析法、放射免疫分析法和被动血凝法测定甲状腺球蛋白自身抗体]。
H Struy, G Horeschi, M Zugehör, J Morenz

A solid-phase enzyme immunoassay, a radioimmunoassay and the passive hemagglutination were tested for the determination of antithyroglobulin autoantibodies. The antibody-titres detected with these methods showed a good correlation. The sensitivities of the solid-phase immunoassays are four times higher than the sensitivity of the passive hemagglutination. For the diagnosis of thyroid autoimmune diseases the enzyme immunoassay.

采用固相酶免疫分析法、放射免疫分析法和被动血凝法测定抗甲状腺球蛋白自身抗体。这些方法检测的抗体滴度具有良好的相关性。固相免疫测定法的灵敏度比被动血凝敏感性高4倍。应用酶免疫分析法诊断甲状腺自身免疫性疾病。
{"title":"[Determination of thyroglobulin autoantibodies using enzyme immunoassay, radioimmunoassay and passive hemagglutination].","authors":"H Struy,&nbsp;G Horeschi,&nbsp;M Zugehör,&nbsp;J Morenz","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A solid-phase enzyme immunoassay, a radioimmunoassay and the passive hemagglutination were tested for the determination of antithyroglobulin autoantibodies. The antibody-titres detected with these methods showed a good correlation. The sensitivities of the solid-phase immunoassays are four times higher than the sensitivity of the passive hemagglutination. For the diagnosis of thyroid autoimmune diseases the enzyme immunoassay.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"9-14"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224983","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Molecular-biological aspects of diabetes mellitus]. [糖尿病的分子生物学方面]。
R Walther, R Brandt, I Leibiger, B Leibiger, S Menzel, C Neumer, H Zühlke
{"title":"[Molecular-biological aspects of diabetes mellitus].","authors":"R Walther,&nbsp;R Brandt,&nbsp;I Leibiger,&nbsp;B Leibiger,&nbsp;S Menzel,&nbsp;C Neumer,&nbsp;H Zühlke","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"124-33"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12844848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Direct positive DDP 111 as a possible means of documentation for electrophoresis]. [直接阳性DDP 111作为电泳记录的可能手段]。
G Knabe, S Gahler, K Peisker, H Roschk

The positivepaper DDP 111 manufactured in the Fotopapierwerk Dresden is presented. It allows to make copies (1:1) of electrophoreses. Independently of the used staining procedure it is a simple, quickly and cameraless possibly to obtain reproductions with a high quality. The DDP 111 allows to resolve the problem of documentation of electropherograms (especially of wet flat gels) and to build up collections and data files respectively.

介绍了在德累斯顿印刷工厂生产的ddp111正片纸。它允许复制(1:1)的电泳。独立使用染色程序,它是一个简单,快速和无相机可能获得高质量的复制品。DDP 111可以解决电泳图(特别是湿平板凝胶)的文档化问题,并分别建立收集和数据文件。
{"title":"[Direct positive DDP 111 as a possible means of documentation for electrophoresis].","authors":"G Knabe,&nbsp;S Gahler,&nbsp;K Peisker,&nbsp;H Roschk","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The positivepaper DDP 111 manufactured in the Fotopapierwerk Dresden is presented. It allows to make copies (1:1) of electrophoreses. Independently of the used staining procedure it is a simple, quickly and cameraless possibly to obtain reproductions with a high quality. The DDP 111 allows to resolve the problem of documentation of electropherograms (especially of wet flat gels) and to build up collections and data files respectively.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"209-12"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12881259","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Some problems in standardization of fructosamine tests]. 果糖胺检验标准化中的几个问题
S Krantz, S Lober, M Lober

The degree of nonenzymatic glycation of serum proteins was estimated in 500 nondiabetic subjects and in 124 Type 2 diabetic out-patients. The values were evaluated in relation to a DMF calibration curve, a secondary glycated protein standard and to serum protein concentrations. Neglecting the evaluation with respect to the protein concentration 0.4% of the samples from nondiabetics and 9% from diabetic patients would have been incorrectly interpreted. The fructosamine values from nondiabetic subjects showed a Gaussian distribution. The use of secondary protein standards is a premise to a widespread application of the fructosamine assay in diabetic care. The calibration of such secondary glycated protein standards results in some problems when using DMF protein mixtures as primary standards, because albumin preparations from the same or different suppliers gave variable standardization curves.

对500名非糖尿病患者和124名2型糖尿病门诊患者血清蛋白的非酶糖化程度进行了估计。将这些值与DMF校准曲线、二级糖化蛋白标准和血清蛋白浓度进行比较。忽略关于蛋白质浓度的评估,0.4%的非糖尿病患者和9%的糖尿病患者的样本将被错误地解释。非糖尿病受试者的果糖胺值呈高斯分布。使用二级蛋白标准是果糖胺测定在糖尿病护理中广泛应用的前提。由于同一或不同供应商的白蛋白制剂给出了不同的标准化曲线,因此在使用DMF蛋白混合物作为一级标准品时,二级糖化蛋白标准品的校准存在一些问题。
{"title":"[Some problems in standardization of fructosamine tests].","authors":"S Krantz,&nbsp;S Lober,&nbsp;M Lober","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The degree of nonenzymatic glycation of serum proteins was estimated in 500 nondiabetic subjects and in 124 Type 2 diabetic out-patients. The values were evaluated in relation to a DMF calibration curve, a secondary glycated protein standard and to serum protein concentrations. Neglecting the evaluation with respect to the protein concentration 0.4% of the samples from nondiabetics and 9% from diabetic patients would have been incorrectly interpreted. The fructosamine values from nondiabetic subjects showed a Gaussian distribution. The use of secondary protein standards is a premise to a widespread application of the fructosamine assay in diabetic care. The calibration of such secondary glycated protein standards results in some problems when using DMF protein mixtures as primary standards, because albumin preparations from the same or different suppliers gave variable standardization curves.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"30-7"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Measurement of spontaneous platelet aggregation in citrated whole blood by application of the hematologic automatic Coulter S plus VI]. [应用血液学自动库尔特S + VI测定柠檬酸全血中自发血小板聚集]。
R Kätzel, W Lösche, B Selle

A method for measurement of the spontaneous platelet aggregation in citrated whole blood (SPAV) was tested using the Coulter Counter S plus VI and a simple mechanism for sample rotation. The underlying principle of the procedure consists in the sequential measurement of the decrease of free platelets in a specimen of citrated whole blood which ist rotated at 37 degrees C for 20 minutes. SPAV offers advantages compared to other methods for spontaneous aggregation in platelet rich plasma. First experiences about application of the SPAV-procedure are presented.

采用库尔特计数器S + VI和简单的样品旋转机制,对柠檬酸全血(SPAV)中自发血小板聚集的测量方法进行了试验。该程序的基本原理是依次测量在37℃下旋转20分钟的柠檬酸全血标本中游离血小板的减少。与其他方法相比,SPAV在富血小板血浆中自发聚集具有优势。介绍了spav程序应用的初步经验。
{"title":"[Measurement of spontaneous platelet aggregation in citrated whole blood by application of the hematologic automatic Coulter S plus VI].","authors":"R Kätzel,&nbsp;W Lösche,&nbsp;B Selle","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A method for measurement of the spontaneous platelet aggregation in citrated whole blood (SPAV) was tested using the Coulter Counter S plus VI and a simple mechanism for sample rotation. The underlying principle of the procedure consists in the sequential measurement of the decrease of free platelets in a specimen of citrated whole blood which ist rotated at 37 degrees C for 20 minutes. SPAV offers advantages compared to other methods for spontaneous aggregation in platelet rich plasma. First experiences about application of the SPAV-procedure are presented.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"44-9"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224455","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[A program for computer-supported immunoassay analysis]. [计算机支持的免疫分析程序]。
J Gabert, G Uhlmann
{"title":"[A program for computer-supported immunoassay analysis].","authors":"J Gabert,&nbsp;G Uhlmann","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 1","pages":"64"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224461","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Analysis of hyaluronic acid in punctates in biochemical functional tests of joints]. 关节生化功能试验中透明质酸含量分析。
R Haupt, H H Heilmann, K Lindenhayn, H Rabe

The punctates of the biochemical joint function test contain hydroxyethyl starch which disturbs the assay of uronic acid and glucosamine for the estimation of hyaluronate. Therefore hyaluronate (0.03-0.75 g/l) was estimated by precipitation with Alcian blue on cellulose acetate membranes and measuring of the absorbance at 678 nm after dissolution in aqueous SDS (75 g/l). The gel-filtration HPLC separates the high-molecular-mass hyaluronate from low-molecular-mass impurities of biological samples. By comparing with a standard curve (0.5-2.5 g/l hyaluronate) the concentration can be determined. The results obtained by the two methods were significantly correlated (p less than 0.05). The Alcian blue technique is useful for rapid screening, the HPLC technique to confirm these values.

生化联合功能试验中含有羟乙基淀粉,会干扰尿酸测定和葡萄糖胺测定透明质酸。因此,透明质酸(0.03-0.75 g/l)是通过阿利新蓝沉淀在醋酸纤维素膜上,并在水溶液SDS (75 g/l)中溶解后测量678 nm处的吸光度来估计的。凝胶过滤高效液相色谱分离生物样品的高分子质量透明质酸和低分子质量杂质。通过与标准曲线(0.5-2.5 g/l透明质酸)比较,可以确定其浓度。两种方法的结果有显著相关(p < 0.05)。阿利新蓝技术可用于快速筛选,高效液相色谱技术可用于确认这些值。
{"title":"[Analysis of hyaluronic acid in punctates in biochemical functional tests of joints].","authors":"R Haupt,&nbsp;H H Heilmann,&nbsp;K Lindenhayn,&nbsp;H Rabe","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The punctates of the biochemical joint function test contain hydroxyethyl starch which disturbs the assay of uronic acid and glucosamine for the estimation of hyaluronate. Therefore hyaluronate (0.03-0.75 g/l) was estimated by precipitation with Alcian blue on cellulose acetate membranes and measuring of the absorbance at 678 nm after dissolution in aqueous SDS (75 g/l). The gel-filtration HPLC separates the high-molecular-mass hyaluronate from low-molecular-mass impurities of biological samples. By comparing with a standard curve (0.5-2.5 g/l hyaluronate) the concentration can be determined. The results obtained by the two methods were significantly correlated (p less than 0.05). The Alcian blue technique is useful for rapid screening, the HPLC technique to confirm these values.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 2","pages":"94-100"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13224992","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Clinical significance of serum concentration of connective tissue components in cases of organic fibroses]. 【器质性纤维化患者血清结缔组织成分浓度的临床意义】。
J Kropf, A M Gressner
{"title":"[Clinical significance of serum concentration of connective tissue components in cases of organic fibroses].","authors":"J Kropf,&nbsp;A M Gressner","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"150-8"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13056873","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Use of a computer in a clinical-toxicological laboratory with a fuzzy search]. [在临床毒理学实验室使用计算机进行模糊搜索]。
J Gehrke, C Haring, H König, H Marin, H Schmidt, G Stolze

If a clinician is faced with acute intoxications a rapid toxicological test is essential. The toxic substances are identified by a combined use of various systems of analysis such as gas chromatography, thin-layer chromatography or UV-spectroscopy. As the result of the analysis a data pattern is obtained which can be interpreted by comparing it with substance-related reference patterns. This paper describes a computer-program which allows more efficient reference comparisons and which gives a support of the decisions. The algorithms of the comparisions are based on fuzzy-theory.

如果临床医生面临急性中毒,快速毒理学试验是必不可少的。有毒物质是通过联合使用各种分析系统,如气相色谱法、薄层色谱法或紫外光谱法来识别的。作为分析的结果,获得了一种数据模式,可以通过将其与与物质相关的参考模式进行比较来解释。本文描述了一个计算机程序,该程序允许更有效的参考比较,并为决策提供支持。比较算法是基于模糊理论的。
{"title":"[Use of a computer in a clinical-toxicological laboratory with a fuzzy search].","authors":"J Gehrke,&nbsp;C Haring,&nbsp;H König,&nbsp;H Marin,&nbsp;H Schmidt,&nbsp;G Stolze","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>If a clinician is faced with acute intoxications a rapid toxicological test is essential. The toxic substances are identified by a combined use of various systems of analysis such as gas chromatography, thin-layer chromatography or UV-spectroscopy. As the result of the analysis a data pattern is obtained which can be interpreted by comparing it with substance-related reference patterns. This paper describes a computer-program which allows more efficient reference comparisons and which gives a support of the decisions. The algorithms of the comparisions are based on fuzzy-theory.</p>","PeriodicalId":76852,"journal":{"name":"Zeitschrift fur medizinische Laboratoriumsdiagnostik","volume":"32 3-4","pages":"197-203"},"PeriodicalIF":0.0,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13056881","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Zeitschrift fur medizinische Laboratoriumsdiagnostik
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1