首页 > 最新文献

2023 Design of Medical Devices Conference最新文献

英文 中文
A CASE STUDY ON ACTIVATION LEVEL OF ROTATOR CUFF MUSCLES USING ELECTROMYOGRAPHY AND ASSOCIATED MUSCLE FORCES 应用肌电图和相关肌肉力量研究肩袖肌的激活水平
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-7918
Allyson Mitchell, AmirHossein Majidirad, G. Pujalte
Rotator cuff tears are among the most common shoulder injuries, making them an attractive topic of study. Yet, there is a lack of clear understanding of attributes associated with deep and superficial muscles when it is intended to study the recovery progress after rehabilitation. Through a systematic approach, this project investigates the activation of rotator cuff muscles using surface electromyography (sEMG) sensors. The team developed a strategic plan to investigate the precision of the NORAXON technology that is utilized in this study to ensure that it is capable of capturing small variations in shoulder motion. This is followed by a reliability analysis to ascertain reproducibility of the experiment. The levels of muscle activities for superficial and deep muscles are monitored to explore the impact of traditionally prescribed arm movements used for the rehabilitation of rotator cuff injuries. Furthermore, an analysis of forces generated in the muscles is done to provide better insight into the activation levels of rotator cuff muscles. The results were promising, with a competent technology and acceptable correlation associated with muscle activities across all subjects. Four common arm movements were studied; scaption generated a significant response in the targeted muscles, particularly of the supraspinatus. Results were conclusive across all subjects, and simulation also supported the experiment showing high activation levels for the supraspinatus. The teres minor also showed a significant contribution when performing external rotation at 90⁰ abduction. The outcome of this study is significant for this ongoing project as it identifies the most impactful exercises that ensure targeted muscles are being triggered. It also lays the groundwork for expanding the project to a clinical study focusing on the most effective arm movements in order to improve rehabilitation process and reduce pertinent cost.
肩袖撕裂是最常见的肩部损伤之一,使其成为一个有吸引力的研究课题。然而,在研究康复后的恢复进展时,对深肌和浅肌的相关属性缺乏清晰的认识。通过系统的方法,本项目研究了使用表面肌电图(sEMG)传感器的肩袖肌肉的激活。该团队制定了一项战略计划,以调查NORAXON技术的精度,该技术在本研究中使用,以确保它能够捕捉肩部运动的微小变化。随后进行可靠性分析,以确定实验的可重复性。监测浅表和深层肌肉的肌肉活动水平,以探索用于肩袖损伤康复的传统处方手臂运动的影响。此外,对肌肉中产生的力进行分析,以更好地了解肩袖肌肉的激活水平。结果是有希望的,在所有的受试者中,都有一个合格的技术和可接受的与肌肉活动相关的相关性。研究了四种常见的手臂动作;绞杀在目标肌肉中产生了显著的反应,特别是冈上肌。所有受试者的结果都是决定性的,模拟也支持冈上肌高激活水平的实验。在进行90⁰外展时,小圆肌也显示出重要的贡献。这项研究的结果对这个正在进行的项目很重要,因为它确定了最有效的运动,确保目标肌肉被触发。这也为将该项目扩展到临床研究奠定了基础,重点关注最有效的手臂运动,以改善康复过程并降低相关成本。
{"title":"A CASE STUDY ON ACTIVATION LEVEL OF ROTATOR CUFF MUSCLES USING ELECTROMYOGRAPHY AND ASSOCIATED MUSCLE FORCES","authors":"Allyson Mitchell, AmirHossein Majidirad, G. Pujalte","doi":"10.1115/dmd2023-7918","DOIUrl":"https://doi.org/10.1115/dmd2023-7918","url":null,"abstract":"\u0000 Rotator cuff tears are among the most common shoulder injuries, making them an attractive topic of study. Yet, there is a lack of clear understanding of attributes associated with deep and superficial muscles when it is intended to study the recovery progress after rehabilitation. Through a systematic approach, this project investigates the activation of rotator cuff muscles using surface electromyography (sEMG) sensors. The team developed a strategic plan to investigate the precision of the NORAXON technology that is utilized in this study to ensure that it is capable of capturing small variations in shoulder motion. This is followed by a reliability analysis to ascertain reproducibility of the experiment. The levels of muscle activities for superficial and deep muscles are monitored to explore the impact of traditionally prescribed arm movements used for the rehabilitation of rotator cuff injuries. Furthermore, an analysis of forces generated in the muscles is done to provide better insight into the activation levels of rotator cuff muscles. The results were promising, with a competent technology and acceptable correlation associated with muscle activities across all subjects. Four common arm movements were studied; scaption generated a significant response in the targeted muscles, particularly of the supraspinatus. Results were conclusive across all subjects, and simulation also supported the experiment showing high activation levels for the supraspinatus. The teres minor also showed a significant contribution when performing external rotation at 90⁰ abduction. The outcome of this study is significant for this ongoing project as it identifies the most impactful exercises that ensure targeted muscles are being triggered. It also lays the groundwork for expanding the project to a clinical study focusing on the most effective arm movements in order to improve rehabilitation process and reduce pertinent cost.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"209 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133557054","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ZAMENIX™ R, ROBOTIC-ASSISTED RETROGRADE INTRARENAL SURGERY SYSTEM FOR RENAL STONE REMOVAL AND ITS EFFICACY AND SAFETY EVALUATION Zamenix™r,机器人辅助逆行肾内手术系统去除肾结石及其疗效和安全性评价
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-7694
Dong-Ho Lee, Joonhwan Kim, Jung-Gil Han, Hyeon Seo, J. Lee, Sung Yong Cho, H. K. Park, D. Kwon
We introduce Zamenix™ R, a novel robotic retrograde intrarenal surgery (RIRS) system that can remotely control a ureteroscope, laser, and stone basket. The efficacy and safety of the system were explored in an in vivo comparative pilot study using a porcine model and a multicenter, prospective, single-arm, pivotal human clinical trial. In the in-vivo test, 10 pigs were randomly divided into two groups: conventional RIRS and robotic RIRS. Three surgeons with different RIRS proficiency participated and they performed two tasks: 1) Stone retrieval test, then followed by 2) Stone fragmentation and retrieval test. In the clinical study, forty-seven adult patients who have one or more stones with a maximum size of 5-30 mm were recruited. The stone-free rate was 93.5%. The postoperative complication rate was 6.5% with three cases of Grade II urinary tract infection (Clavien-Dindo Classification). The experimental results demonstrated the feasibility and comparable safety to conventional RIRS with improved operator’s fatigue and radiation exposure.
我们介绍了Zamenix™R,一种新型机器人逆行肾内手术(RIRS)系统,可以远程控制输尿管镜,激光和石筐。通过猪模型和多中心、前瞻性、单臂、关键的人体临床试验,对该系统的有效性和安全性进行了体内比较初步研究。在体内试验中,将10头猪随机分为两组,分别为常规RIRS组和机器人RIRS组。3名不同RIRS熟练程度的外科医生参与其中,他们完成了2项任务:1)结石取出测试,然后是2)结石碎裂和取出测试。在临床研究中,招募了47名患有一个或多个最大尺寸为5- 30mm的结石的成年患者。无石率为93.5%。术后并发症发生率为6.5%,2级尿路感染3例(Clavien-Dindo分类)。实验结果证明了该方法的可行性和与常规RIRS相当的安全性,并改善了操作人员的疲劳和辐射暴露。
{"title":"ZAMENIX™ R, ROBOTIC-ASSISTED RETROGRADE INTRARENAL SURGERY SYSTEM FOR RENAL STONE REMOVAL AND ITS EFFICACY AND SAFETY EVALUATION","authors":"Dong-Ho Lee, Joonhwan Kim, Jung-Gil Han, Hyeon Seo, J. Lee, Sung Yong Cho, H. K. Park, D. Kwon","doi":"10.1115/dmd2023-7694","DOIUrl":"https://doi.org/10.1115/dmd2023-7694","url":null,"abstract":"\u0000 We introduce Zamenix™ R, a novel robotic retrograde intrarenal surgery (RIRS) system that can remotely control a ureteroscope, laser, and stone basket. The efficacy and safety of the system were explored in an in vivo comparative pilot study using a porcine model and a multicenter, prospective, single-arm, pivotal human clinical trial. In the in-vivo test, 10 pigs were randomly divided into two groups: conventional RIRS and robotic RIRS. Three surgeons with different RIRS proficiency participated and they performed two tasks: 1) Stone retrieval test, then followed by 2) Stone fragmentation and retrieval test. In the clinical study, forty-seven adult patients who have one or more stones with a maximum size of 5-30 mm were recruited. The stone-free rate was 93.5%. The postoperative complication rate was 6.5% with three cases of Grade II urinary tract infection (Clavien-Dindo Classification). The experimental results demonstrated the feasibility and comparable safety to conventional RIRS with improved operator’s fatigue and radiation exposure.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121585052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
DESIGN OF AN MRI-COMPATIBLE ROBOT FOR IMAGE-GUIDED NEEDLE INSERTION PROCEDURES USING ACTIVE TENDON-DRIVEN NEEDLES 一种mri兼容机器人的设计,用于使用主动肌腱驱动的针头进行图像引导的针头插入过程
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-2247
Samuel Lafreniere, Olivia Lee Sprouse, Ryan Justin Padilla, B. Konh
Visualization and tip tracking of needles inside the body in needle-based interventions are usually challenging using conventional medical imaging modalities such as ultrasound and CT. MRI provides an amazing imaging feedback for the operator to target lesions with a great confidence. However, the needle should be operated teleoperatively using a robot interface. This work introduces a novel design of an MRI-compatible (slave) robot for image-guided needle insertions. The robot is designed with MRI-compatible materials and actuators to enable manual initial positioning inside the MRI bore prior to operation, as well as robotic teleoperation (insertion and actuation) of an active tendon-driven needle towards targets. The range of motion is shown to be appropriate for transperineal prostate interventions such as prostate biopsy and brachytherapy.
使用传统的医学成像方式,如超声和CT,在基于针头的干预中,对体内针头的可视化和尖端跟踪通常具有挑战性。MRI为操作人员提供了惊人的成像反馈,使他们能够充满信心地定位病灶。然而,针应该使用机器人接口进行远程操作。这项工作介绍了一种用于图像引导针头插入的mri兼容(从)机器人的新设计。该机器人设计了与MRI兼容的材料和致动器,可以在手术前在MRI孔内手动初始定位,以及机器人远程操作(插入和驱动)一个主动肌腱驱动的针指向目标。经会阴前列腺干预,如前列腺活检和近距离放射治疗,其活动范围是合适的。
{"title":"DESIGN OF AN MRI-COMPATIBLE ROBOT FOR IMAGE-GUIDED NEEDLE INSERTION PROCEDURES USING ACTIVE TENDON-DRIVEN NEEDLES","authors":"Samuel Lafreniere, Olivia Lee Sprouse, Ryan Justin Padilla, B. Konh","doi":"10.1115/dmd2023-2247","DOIUrl":"https://doi.org/10.1115/dmd2023-2247","url":null,"abstract":"\u0000 Visualization and tip tracking of needles inside the body in needle-based interventions are usually challenging using conventional medical imaging modalities such as ultrasound and CT. MRI provides an amazing imaging feedback for the operator to target lesions with a great confidence. However, the needle should be operated teleoperatively using a robot interface. This work introduces a novel design of an MRI-compatible (slave) robot for image-guided needle insertions. The robot is designed with MRI-compatible materials and actuators to enable manual initial positioning inside the MRI bore prior to operation, as well as robotic teleoperation (insertion and actuation) of an active tendon-driven needle towards targets. The range of motion is shown to be appropriate for transperineal prostate interventions such as prostate biopsy and brachytherapy.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125918229","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
LAPAROSCOPIC TROCAR INSERTION FORCE SIMULATION 腹腔镜套管针插入力模拟
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-4027
Samson Galvin, Samantha Scarpinella, Dr. Shawn Safford, Dr. Scarlett Miller, Dr. Jason Moore
Laparoscopic surgery is a common minimally invasive procedure that is performed through small ports in the abdominal wall. The ports are created with tools called trocars that are used to inflate the abdominal cavity and are used as gateways for surgical tools. There is limited training on trocar insertion for novice surgeons and it is a crucial step in the laparoscopic procedure. There are several challenges associated with placing and inserting trocars in the abdominal area. In this paper, experimental data is used to create a mathematical model for the expected trocar force, which had an average error of 3.67%. A novel trocar training system is proposed to effectively simulate the haptic feeling of inserting a trocar into the abdomen.
腹腔镜手术是一种常见的微创手术,通过腹壁的小孔进行。这些端口是由一种叫做套管针的工具创建的,这种工具用于给腹腔充气,并用作手术工具的通道。新手外科医生对套管针插入的培训有限,这是腹腔镜手术中至关重要的一步。在腹部区域放置和插入套管针有几个挑战。本文利用实验数据建立了套管针预期受力的数学模型,平均误差为3.67%。提出了一种新颖的套管针训练系统,可以有效地模拟套管针插入腹部的触感。
{"title":"LAPAROSCOPIC TROCAR INSERTION FORCE SIMULATION","authors":"Samson Galvin, Samantha Scarpinella, Dr. Shawn Safford, Dr. Scarlett Miller, Dr. Jason Moore","doi":"10.1115/dmd2023-4027","DOIUrl":"https://doi.org/10.1115/dmd2023-4027","url":null,"abstract":"\u0000 Laparoscopic surgery is a common minimally invasive procedure that is performed through small ports in the abdominal wall. The ports are created with tools called trocars that are used to inflate the abdominal cavity and are used as gateways for surgical tools. There is limited training on trocar insertion for novice surgeons and it is a crucial step in the laparoscopic procedure. There are several challenges associated with placing and inserting trocars in the abdominal area. In this paper, experimental data is used to create a mathematical model for the expected trocar force, which had an average error of 3.67%. A novel trocar training system is proposed to effectively simulate the haptic feeling of inserting a trocar into the abdomen.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125955527","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A COMPARISON OF THE PRESSURE FAILURE OF TWO COLORECTAL ANASTAMOSES STAPLING TECHNIQUES 两种结直肠吻合器加压失败的比较
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-8985
Youssef Fahmy, M. Trabia, Brian Ward, L. Gallup, Whitney Elks
Anastomotic leakage (AL) is a serious complication that effects thousands of patients undergoing colorectal surgery annually. Stapling is generally used to perform anastomoses. Two common anastomosis techniques are the End to End (EE), and End to Side (ES). Currently there is no experimental approach to compare the effectiveness of these two techniques against AL. This work proposes an ex-vivo experimental setup of burst testing of anastomoses using porcine tissues. Twelve pigs were used with three specimens harvested from the colon of each of them: EE, ES, and a control specimen. Failure of the anastomoses were monitored, and the corresponding leakage pressures were recorded. Preliminary results indicated that ES led to higher strength than EE.
吻合口瘘(AL)是每年影响成千上万结直肠手术患者的严重并发症。吻合器通常用于吻合术。两种常见的吻合技术是端到端(EE)和端到侧(ES)。目前还没有实验方法来比较这两种技术对AL的有效性。本研究提出了一种利用猪组织进行吻合口爆裂测试的离体实验装置。使用12头猪,每头猪结肠取3个标本:EE、ES和一个对照标本。监测吻合口失效情况,记录相应的泄漏压力。初步结果表明,ES的强度高于EE。
{"title":"A COMPARISON OF THE PRESSURE FAILURE OF TWO COLORECTAL ANASTAMOSES STAPLING TECHNIQUES","authors":"Youssef Fahmy, M. Trabia, Brian Ward, L. Gallup, Whitney Elks","doi":"10.1115/dmd2023-8985","DOIUrl":"https://doi.org/10.1115/dmd2023-8985","url":null,"abstract":"\u0000 Anastomotic leakage (AL) is a serious complication that effects thousands of patients undergoing colorectal surgery annually. Stapling is generally used to perform anastomoses. Two common anastomosis techniques are the End to End (EE), and End to Side (ES). Currently there is no experimental approach to compare the effectiveness of these two techniques against AL. This work proposes an ex-vivo experimental setup of burst testing of anastomoses using porcine tissues. Twelve pigs were used with three specimens harvested from the colon of each of them: EE, ES, and a control specimen. Failure of the anastomoses were monitored, and the corresponding leakage pressures were recorded. Preliminary results indicated that ES led to higher strength than EE.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128794874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CONVECTION ENHANCED THERMO-CHEMOTHERAPY CATHETER SYSTEM: PRE-510(K) CLEARANCE PROTOCOL DEVELOPMENT: FLUID PERFORMANCE TESTING 对流增强热化疗导管系统:pre-510 (k)清除协议开发:流体性能测试
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-3181
Brianna E. Morales, Christopher G. Rylander
Our lab is developing a novel device, the convection-enhanced thermo-chemotherapy catheter system (CETCS), to improve drug dispersal around a glioblastoma. To help prepare the device for clinical trials, we were advised to first prepare and receive 510(k)-clearance. The 510(k)-clearance process includes proving the novel device is substantially equivalent to a previously cleared predicate device. For the CETCS device, we have identified the Cleveland Multiport Catheter (CMC) as our predicate device. In this work, we test infusion pump flow rate, high-pressure flow rate, and microneedle tip deflection; each with respect to infusion and aspiration. The CMC’s 510(k) summary sheet provided guidelines for the test protocols to follow. If the CMC’s 510(k) summary did not state a metric, we set the metric based on the CETCS device specifications. Replicating or exceeding the threshold passing criteria set by the CMC device or the CETCS specifications demonstrates that CETCS is substantially equivalent to the predicate device for those specific metrics.
我们的实验室正在开发一种新型设备,对流增强热化疗导管系统(CETCS),以改善胶质母细胞瘤周围的药物分散。为了帮助器械准备临床试验,我们被建议首先准备并获得510(k)许可。510(k)批准过程包括证明新设备实质上等同于先前批准的谓词设备。对于CETCS设备,我们已经确定了克利夫兰多端口导管(CMC)作为我们的首选设备。在这项工作中,我们测试了输液泵流量、高压流量和微针尖端挠度;关于输注和抽吸。CMC的510(k)摘要表提供了测试方案遵循的指导方针。如果CMC的510(k)摘要没有说明度量,我们根据CETCS设备规格设置度量。复制或超过CMC设备或CETCS规范设置的通过标准的阈值,表明CETCS实质上等同于这些特定指标的谓词设备。
{"title":"CONVECTION ENHANCED THERMO-CHEMOTHERAPY CATHETER SYSTEM: PRE-510(K) CLEARANCE PROTOCOL DEVELOPMENT: FLUID PERFORMANCE TESTING","authors":"Brianna E. Morales, Christopher G. Rylander","doi":"10.1115/dmd2023-3181","DOIUrl":"https://doi.org/10.1115/dmd2023-3181","url":null,"abstract":"\u0000 Our lab is developing a novel device, the convection-enhanced thermo-chemotherapy catheter system (CETCS), to improve drug dispersal around a glioblastoma. To help prepare the device for clinical trials, we were advised to first prepare and receive 510(k)-clearance. The 510(k)-clearance process includes proving the novel device is substantially equivalent to a previously cleared predicate device. For the CETCS device, we have identified the Cleveland Multiport Catheter (CMC) as our predicate device. In this work, we test infusion pump flow rate, high-pressure flow rate, and microneedle tip deflection; each with respect to infusion and aspiration. The CMC’s 510(k) summary sheet provided guidelines for the test protocols to follow. If the CMC’s 510(k) summary did not state a metric, we set the metric based on the CETCS device specifications. Replicating or exceeding the threshold passing criteria set by the CMC device or the CETCS specifications demonstrates that CETCS is substantially equivalent to the predicate device for those specific metrics.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"81 6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116349423","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ITINERARY PREDICTIVE ANALYTICS: AI BASED SOFTWARE AS A MEDICAL DEVICE TO PREDICT PATIENTS’ FIRST VISIT ITINERARY FOR HEALTHCARE ADMINISTRATION 行程预测分析:基于人工智能的软件作为一种医疗设备,用于预测患者的首次就诊行程,以供医疗管理部门使用
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-1597
S. Damani, K. Gopalakrishnan, Keirthana Aedma, Pratyusha Muddaloor, V. Chandrasekhara, Alexander J. Ryu, Christopher A. Aakre, S. P. Arunachalam
Majority of hospitals still utilize manual methods for patient scheduling and predicting future appointments, resulting in longer wait times, hospital burnout and inadequate use of resources. A variety of avenues have been explored, including priority patient routing, tele-health, neural networks for improving ER efficiency, predicting no-shows, consultation duration variations, and optimizing operating room utilization. Addressing this issue, a study was conducted using 700 pre-visit notes of pancreatic patients to determine the requirement of endoscopic or biliary procedure. Through natural language processing and traditional or transfer learning algorithms, data could directly be sent to EPIC for nurses to assess in further decision making. Performance of the models was above average with the transfer learning method outperforming the traditional method. Although limited by less dataset and fewer circumstances to test the models on, the results exposed potential for future development with the possibility of patients reporting their chief concerns, in turn analyzed by algorithms, ultimately creating a smooth and effective patient itinerary.
大多数医院仍然使用人工方法来安排病人日程和预测未来的预约,导致等待时间更长,医院倦怠和资源利用不足。已经探索了各种途径,包括优先患者路径,远程医疗,用于提高急诊室效率的神经网络,预测未就诊,会诊时间变化以及优化手术室利用率。针对这一问题,一项研究使用了700例胰腺患者的就诊前记录来确定内镜或胆道手术的需求。通过自然语言处理和传统或迁移学习算法,数据可以直接发送到EPIC,供护士在进一步决策时进行评估。模型的性能均高于平均水平,迁移学习方法优于传统方法。尽管受限于较少的数据集和较少的环境来测试模型,但结果显示了未来发展的潜力,患者可能会报告他们的主要问题,进而通过算法进行分析,最终创建一个顺利有效的患者行程。
{"title":"ITINERARY PREDICTIVE ANALYTICS: AI BASED SOFTWARE AS A MEDICAL DEVICE TO PREDICT PATIENTS’ FIRST VISIT ITINERARY FOR HEALTHCARE ADMINISTRATION","authors":"S. Damani, K. Gopalakrishnan, Keirthana Aedma, Pratyusha Muddaloor, V. Chandrasekhara, Alexander J. Ryu, Christopher A. Aakre, S. P. Arunachalam","doi":"10.1115/dmd2023-1597","DOIUrl":"https://doi.org/10.1115/dmd2023-1597","url":null,"abstract":"\u0000 Majority of hospitals still utilize manual methods for patient scheduling and predicting future appointments, resulting in longer wait times, hospital burnout and inadequate use of resources. A variety of avenues have been explored, including priority patient routing, tele-health, neural networks for improving ER efficiency, predicting no-shows, consultation duration variations, and optimizing operating room utilization. Addressing this issue, a study was conducted using 700 pre-visit notes of pancreatic patients to determine the requirement of endoscopic or biliary procedure. Through natural language processing and traditional or transfer learning algorithms, data could directly be sent to EPIC for nurses to assess in further decision making. Performance of the models was above average with the transfer learning method outperforming the traditional method. Although limited by less dataset and fewer circumstances to test the models on, the results exposed potential for future development with the possibility of patients reporting their chief concerns, in turn analyzed by algorithms, ultimately creating a smooth and effective patient itinerary.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116358578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
HAND MOVEMENT GLOVE FOR CHILD WITH TITINOPATHY 为患有视网膜病变的儿童准备的手部运动手套
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-9287
Hannah Bass, C. Foster, Akshaya Santhanaraj, Shourya Kumar
Patients with titinopathy or hand paralysis often lack quality, low cost therapeutic tools to aid in gaining hand strength and range of motion. As a result, our team sought to develop a way to increase flexion and passive motion in the hand of a patient with titinopathy in order to gain functionality. This paper outlines the design and development of a novel therapeutic glove for a 4 year old boy with a neuromuscular disease that prevents him from flexing the two distal joints of his fingers. The team has developed a low-cost hand movement glove (HMG) to be used as a supplement to traditional physical therapy. The device utilizes a motor-cable system secured to each finger, allowing for independent and synchronized flexion of each finger. Phase I of prototyping resulted in a working model to assess the finger movement mechanism and overall wearability of the device. Phase II utilized an Arduino Uno microcontroller, circuit switch, PCA9685 driver board, micro servo motors, a cotton woven glove, and 3-D printed components to characterize a more robust model allowing independent flexion of each finger. Initial testing has proven the device’s ability to achieve physiologically relevant degrees of flexion in each finger. Upon completion of further testing, we anticipate this device having a profound impact as an additional tool utilized in the patient’s physical therapy regimen to allow for regained flexion at both proximal and distal interphalangeal joints.
患有视网膜病变或手部麻痹的患者通常缺乏高质量、低成本的治疗工具来帮助他们增强手部力量和活动范围。因此,我们的团队试图开发一种方法来增加患者的屈曲和被动运动的手,以获得功能。本文概述了一种新型治疗手套的设计和开发,用于一名患有神经肌肉疾病的4岁男孩,该疾病使他无法弯曲手指的两个远端关节。该团队开发了一种低成本的手部运动手套(HMG),作为传统物理治疗的补充。该设备利用固定在每个手指上的电机电缆系统,允许每个手指独立和同步弯曲。原型设计的第一阶段产生了一个工作模型,以评估手指运动机制和设备的整体可穿戴性。第二阶段使用Arduino Uno微控制器、电路开关、PCA9685驱动板、微型伺服电机、棉织手套和3d打印组件来表征一个更强大的模型,允许每个手指独立弯曲。最初的测试已经证明,该设备能够在每个手指上实现生理上相关的屈曲程度。在完成进一步的测试后,我们预计该装置将作为患者物理治疗方案中使用的额外工具产生深远的影响,以允许近端和远端指间关节恢复屈曲。
{"title":"HAND MOVEMENT GLOVE FOR CHILD WITH TITINOPATHY","authors":"Hannah Bass, C. Foster, Akshaya Santhanaraj, Shourya Kumar","doi":"10.1115/dmd2023-9287","DOIUrl":"https://doi.org/10.1115/dmd2023-9287","url":null,"abstract":"\u0000 Patients with titinopathy or hand paralysis often lack quality, low cost therapeutic tools to aid in gaining hand strength and range of motion. As a result, our team sought to develop a way to increase flexion and passive motion in the hand of a patient with titinopathy in order to gain functionality. This paper outlines the design and development of a novel therapeutic glove for a 4 year old boy with a neuromuscular disease that prevents him from flexing the two distal joints of his fingers.\u0000 The team has developed a low-cost hand movement glove (HMG) to be used as a supplement to traditional physical therapy. The device utilizes a motor-cable system secured to each finger, allowing for independent and synchronized flexion of each finger. Phase I of prototyping resulted in a working model to assess the finger movement mechanism and overall wearability of the device. Phase II utilized an Arduino Uno microcontroller, circuit switch, PCA9685 driver board, micro servo motors, a cotton woven glove, and 3-D printed components to characterize a more robust model allowing independent flexion of each finger.\u0000 Initial testing has proven the device’s ability to achieve physiologically relevant degrees of flexion in each finger. Upon completion of further testing, we anticipate this device having a profound impact as an additional tool utilized in the patient’s physical therapy regimen to allow for regained flexion at both proximal and distal interphalangeal joints.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126101635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ARRHYTHMIC SUDDEN DEATH SURVIVAL PREDICTION MODEL FOR HYPERTROPHIC CARDIOMYOPATHY PATIENTS: AN INTERPRETABLE MACHINE LEARNING ANALYSIS 肥厚性心肌病患者心律失常猝死生存预测模型:可解释的机器学习分析
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-2989
N. Farahani, Moein Enayati, Andredi Pumarejo, Mateo Alzate Aguirre, Christopher G. Scott, Konstantinos C. Siontis, Martijn Bos, J. Geske, M. Ackerman, Adelaide M. Arruda-Olson
Hypertrophic Cardiomyopathy (HCM) is an inheritable heart disease with the highest rate of sudden cardiac death (SCD) in young adults. Implantable Cardioverter Defibrillator (ICD) therapy is recommended for HCM patients at high risk for SCD. Reviewing the recent clinical literature revealed the potential to improve the selection of candidates for ICD implantation. The current study uses information extracted from echocardiography reports to evaluate HCM patients with ICD and aims to provide a comparative insight into patients who benefited the most from the device therapy, including shock and anti-tachycardia pacing (ATP). The proposed interpretable machine learning approach has used the XGboost algorithm. The model’s performance was considered satisfactory, as evidenced by an accuracy score of 81% and an area under the receiver operating characteristic curve (AUC) value of 69% and SHapley Additive exPlanations (SHAP) identified common properties of HCM patients in each category and provided high-level reasoning and foundation for a clinical decision support tool.
肥厚性心肌病(HCM)是一种遗传性心脏病,在年轻人中心脏性猝死(SCD)的发生率最高。植入式心律转复除颤器(ICD)治疗推荐HCM患者在SCD的高风险。回顾最近的临床文献揭示了改善ICD植入候选人选择的潜力。目前的研究使用超声心动图报告中提取的信息来评估HCM合并ICD患者,旨在提供从器械治疗(包括休克和抗心动过速起搏(ATP))中获益最多的患者的比较见解。提出的可解释机器学习方法使用了XGboost算法。模型的准确性评分为81%,受试者工作特征曲线下面积(AUC)值为69%,SHapley加性解释(SHAP)识别了HCM患者在每个类别中的共同特征,为临床决策支持工具提供了高级推理和基础。
{"title":"ARRHYTHMIC SUDDEN DEATH SURVIVAL PREDICTION MODEL FOR HYPERTROPHIC CARDIOMYOPATHY PATIENTS: AN INTERPRETABLE MACHINE LEARNING ANALYSIS","authors":"N. Farahani, Moein Enayati, Andredi Pumarejo, Mateo Alzate Aguirre, Christopher G. Scott, Konstantinos C. Siontis, Martijn Bos, J. Geske, M. Ackerman, Adelaide M. Arruda-Olson","doi":"10.1115/dmd2023-2989","DOIUrl":"https://doi.org/10.1115/dmd2023-2989","url":null,"abstract":"\u0000 Hypertrophic Cardiomyopathy (HCM) is an inheritable heart disease with the highest rate of sudden cardiac death (SCD) in young adults. Implantable Cardioverter Defibrillator (ICD) therapy is recommended for HCM patients at high risk for SCD. Reviewing the recent clinical literature revealed the potential to improve the selection of candidates for ICD implantation. The current study uses information extracted from echocardiography reports to evaluate HCM patients with ICD and aims to provide a comparative insight into patients who benefited the most from the device therapy, including shock and anti-tachycardia pacing (ATP). The proposed interpretable machine learning approach has used the XGboost algorithm. The model’s performance was considered satisfactory, as evidenced by an accuracy score of 81% and an area under the receiver operating characteristic curve (AUC) value of 69% and SHapley Additive exPlanations (SHAP) identified common properties of HCM patients in each category and provided high-level reasoning and foundation for a clinical decision support tool.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124648692","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
EXTRACELLULAR FLOW PATTERNS SURROUNDING A BREAST CANCER CELL DURING TRANSPORT IN A MICROCHANNEL 乳腺癌细胞在微通道中运输过程中的细胞外流动模式
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-7947
Lahcen Akerkouch, Trung Le, Amanda Haage, Aaron Vanyo
We performed the transport of a breast cancer cell (MB231-TGFb) in a microvessel using high-resolution simulations. Using open-source imaging software Slicer3D and Meshmixer, the 3D surface mesh forming the cell membrane was reconstructed from confocal microscopic images. The Dissipative Particle Dynamics method is used to model the cell membrane. The extracellular fluid flow is modeled with the Immersed Boundary Method to solve the governing equations of the blood plasma. The unsteady flow is applied at the inlet of the microchannel with an oscillatory pattern. Our results showed that the extracellular flow patterns are highly dependent on the waveform profile. The oscillatory flow showed the creation of vortices that influence the cellular deformations in the microchannel. These results could have implications on the destination of the cancer cells during transport in physiological flows.
我们使用高分辨率模拟在微血管中进行乳腺癌细胞(MB231-TGFb)的运输。利用开源成像软件Slicer3D和Meshmixer,从共聚焦显微图像中重构形成细胞膜的三维表面网格。采用耗散粒子动力学方法对细胞膜进行建模。采用浸入边界法对胞外液流动进行建模,求解血浆的控制方程。非定常流以振荡形式施加于微通道入口。我们的结果表明,细胞外流动模式高度依赖于波形剖面。振荡流动显示了影响微通道中细胞变形的漩涡的产生。这些结果可能对癌细胞在生理流动中运输的目的地有影响。
{"title":"EXTRACELLULAR FLOW PATTERNS SURROUNDING A BREAST CANCER CELL DURING TRANSPORT IN A MICROCHANNEL","authors":"Lahcen Akerkouch, Trung Le, Amanda Haage, Aaron Vanyo","doi":"10.1115/dmd2023-7947","DOIUrl":"https://doi.org/10.1115/dmd2023-7947","url":null,"abstract":"\u0000 We performed the transport of a breast cancer cell (MB231-TGFb) in a microvessel using high-resolution simulations. Using open-source imaging software Slicer3D and Meshmixer, the 3D surface mesh forming the cell membrane was reconstructed from confocal microscopic images. The Dissipative Particle Dynamics method is used to model the cell membrane. The extracellular fluid flow is modeled with the Immersed Boundary Method to solve the governing equations of the blood plasma. The unsteady flow is applied at the inlet of the microchannel with an oscillatory pattern. Our results showed that the extracellular flow patterns are highly dependent on the waveform profile. The oscillatory flow showed the creation of vortices that influence the cellular deformations in the microchannel. These results could have implications on the destination of the cancer cells during transport in physiological flows.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121094810","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
2023 Design of Medical Devices Conference
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1