EXPERIMENTAL VALIDATION OF A COMPUTATIONAL KNEE MODEL OF TKR IMPLANT PLACEMENT TKR假体置入计算膝关节模型的实验验证
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-5598
Aaron Henry, G. Goodchild, Jonathan B Greenwald, M. Meftah, Michael Moreno, Andrew B. Robbins
The goal of this work was to experimentally validate a computational model for TKRs to improve implant alignment accuracy and assess potential implant misalignment during preoperative planning. Initial validation of the model was achieved by comparing ligament strain energies between the computational model and a physical knee model comprised of bone and ligament analogues. Experimental validation would be considered met when the computational model strain energies were within 10% of the measured values for all six physical knees. Physical and computational knee models were created with six variations of implant alignment to test the robustness of the computational model. Strain energy errors were well within the 10% threshold across knee range of motion.
这项工作的目的是通过实验验证tkr的计算模型,以提高种植体对准精度,并在术前计划中评估潜在的种植体错位。通过比较计算模型和由骨和韧带类似物组成的物理膝关节模型之间的韧带应变能,实现了模型的初步验证。当计算模型应变能在所有六个物理膝关节的实测值的10%以内时,认为满足实验验证。用六种不同的假体对齐方式创建物理和计算膝关节模型,以测试计算模型的稳健性。应变能误差在整个膝关节运动范围内的10%阈值内。
{"title":"EXPERIMENTAL VALIDATION OF A COMPUTATIONAL KNEE MODEL OF TKR IMPLANT PLACEMENT","authors":"Aaron Henry, G. Goodchild, Jonathan B Greenwald, M. Meftah, Michael Moreno, Andrew B. Robbins","doi":"10.1115/dmd2023-5598","DOIUrl":"https://doi.org/10.1115/dmd2023-5598","url":null,"abstract":"\u0000 The goal of this work was to experimentally validate a computational model for TKRs to improve implant alignment accuracy and assess potential implant misalignment during preoperative planning. Initial validation of the model was achieved by comparing ligament strain energies between the computational model and a physical knee model comprised of bone and ligament analogues. Experimental validation would be considered met when the computational model strain energies were within 10% of the measured values for all six physical knees. Physical and computational knee models were created with six variations of implant alignment to test the robustness of the computational model. Strain energy errors were well within the 10% threshold across knee range of motion.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131559954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
DESIGN OF AN INSERTION FUNNEL FOR A TRAINING SYSTEM FOR CENTRAL VENOUS CATHETER GUIDEWIRE INSERTION 中心静脉导管导丝置入训练系统的置入漏斗设计
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-7767
Margaret Krieger, Aayod Kaul, Dailen C. Brown, Haroula M. Tzamaras, J. Moore, Scarlett R. Miller
A novel concept is proposed to effectively measure and train central venous catheter guidewire insertion. This system utilizes a 3D printed funnel to direct the insertion of a guidewire from multiple angles and positions. This directed guidewire can then be passed through previously developed sensors to provide the user with valuable training feedback. Experiments are performed to measure the effectiveness of the funnel system under varying insertion positions, angles, and funnel coatings. After experimentation, it was found that a funnel greased with white lithium grease allows the guidewire to successfully make it through the funnel compared to alternatives tested. This design will be applied to the Dynamic Haptic Robotic Trainer Plus (DHRT+) system to train medical residents to safely perform central venous catheterization.
提出了一种有效测量和训练中心静脉导管导丝插入的新方法。该系统利用3D打印漏斗从多个角度和位置引导导丝的插入。这种定向导丝可以通过以前开发的传感器,为用户提供有价值的培训反馈。在不同的插入位置、角度和漏斗涂层下,进行了实验来测量漏斗系统的有效性。实验后发现,与测试的替代方案相比,涂有白色锂脂的漏斗可以使导丝成功通过漏斗。该设计将应用于Dynamic Haptic Robotic Trainer Plus (DHRT+)系统,用于培训住院医生安全进行中心静脉置管。
{"title":"DESIGN OF AN INSERTION FUNNEL FOR A TRAINING SYSTEM FOR CENTRAL VENOUS CATHETER GUIDEWIRE INSERTION","authors":"Margaret Krieger, Aayod Kaul, Dailen C. Brown, Haroula M. Tzamaras, J. Moore, Scarlett R. Miller","doi":"10.1115/dmd2023-7767","DOIUrl":"https://doi.org/10.1115/dmd2023-7767","url":null,"abstract":"\u0000 A novel concept is proposed to effectively measure and train central venous catheter guidewire insertion. This system utilizes a 3D printed funnel to direct the insertion of a guidewire from multiple angles and positions. This directed guidewire can then be passed through previously developed sensors to provide the user with valuable training feedback. Experiments are performed to measure the effectiveness of the funnel system under varying insertion positions, angles, and funnel coatings. After experimentation, it was found that a funnel greased with white lithium grease allows the guidewire to successfully make it through the funnel compared to alternatives tested. This design will be applied to the Dynamic Haptic Robotic Trainer Plus (DHRT+) system to train medical residents to safely perform central venous catheterization.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131947802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
STIMULATION OF THE LINGUAL NERVE FOR INCREASED SALIVA OUTPUT 刺激舌神经增加唾液分泌
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-9277
N. Johnson, Matthew D. Johnson
Xerostomia is the perception of oral dryness. In addition to discomfort, xerostomia can lead to several long-term medical complications within the oral cavity and gastrointestinal system. Treatment options are limited and are either not effective or not convenient for all people with xerostomia. In this study, we designed, tested, and further developed an oral mouth guard insert with electrodes for stimulating the lingual nerve on the medial side of the lower jawbone. Saliva production, collected in the context of randomized on/off testing with a subject blinded to the test condition, resulted in significantly more saliva output during and following lingual stimulation (2.07 g over one minute) versus off stimulation control conditions (1.58 g also over one minute) (two-sample t-test, p=0.001). The proof-of-concept prototype is poised for further refinement with system integration and improvement in packaging. Xerostomia is a common medical condition, and non-implantable devices that can increase salivation on-demand hold significant promise for treating xerostomia in the broader public.
口干症是口腔干燥的感觉。除了不适之外,口干症还会导致口腔和胃肠道系统的一些长期并发症。治疗选择是有限的,对所有口干症患者不是有效就是不方便。在这项研究中,我们设计、测试并进一步开发了一种带有电极的口腔保护插入物,用于刺激下颌骨内侧的舌神经。唾液的产生,在随机开/关测试的背景下收集,受试者对测试条件不了解,在舌刺激期间和之后的唾液分泌量(一分钟2.07 g)明显高于不刺激控制条件(一分钟1.58 g)(双样本t检验,p=0.001)。概念验证原型准备进一步细化与系统集成和改进包装。口干症是一种常见的医疗状况,非植入式设备可以按需增加唾液分泌,对治疗口干症有很大的希望。
{"title":"STIMULATION OF THE LINGUAL NERVE FOR INCREASED SALIVA OUTPUT","authors":"N. Johnson, Matthew D. Johnson","doi":"10.1115/dmd2023-9277","DOIUrl":"https://doi.org/10.1115/dmd2023-9277","url":null,"abstract":"\u0000 Xerostomia is the perception of oral dryness. In addition to discomfort, xerostomia can lead to several long-term medical complications within the oral cavity and gastrointestinal system. Treatment options are limited and are either not effective or not convenient for all people with xerostomia. In this study, we designed, tested, and further developed an oral mouth guard insert with electrodes for stimulating the lingual nerve on the medial side of the lower jawbone. Saliva production, collected in the context of randomized on/off testing with a subject blinded to the test condition, resulted in significantly more saliva output during and following lingual stimulation (2.07 g over one minute) versus off stimulation control conditions (1.58 g also over one minute) (two-sample t-test, p=0.001). The proof-of-concept prototype is poised for further refinement with system integration and improvement in packaging. Xerostomia is a common medical condition, and non-implantable devices that can increase salivation on-demand hold significant promise for treating xerostomia in the broader public.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123916146","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PREVENTING THE PROGRESSION OF DIABETIC FOOT ULCERS: ADDRESSING PATIENT COMPLIANCE WITH LOW-COST, BEHAVIOR-MODIFYING WEARABLES 预防糖尿病足溃疡的进展:解决患者对低成本,行为改变可穿戴设备的依从性
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-7569
Carine Rizk, Koby Reid, K. Tran, Hannah Bass
Over 34.2M Americans have diabetes and $237B is spent on direct costs of diabetes each year. Of this, $15B is spent on foot ulcer treatment alone as more than half of people with diabetes develop some type of neuropathy, the primary modifiable risk factor of ulcers in this population. Currently, patients with diabetic peripheral neuropathy (DPN) rely on early hotspot identification, padded soles, offloading boots, and diabetic shoes, with compliance being the major issue. Through expert interviews, there is a need for a better method to slow and prevent the progression of hot spots and other complications in patients with DPN. Our team is proposing DiaSense, a wearable device that replaces the lost sensation of pain with a safe and actionable stimulus that modifies gait to offload hotspots. The discrete design was guided by experiences from patients, podiatrists, and vascular surgeons to improve patient compliance, satisfaction, and recovery. Early user-feedback demonstrated useful validation that our device modifies walking behavior in healthy participants, and helps justify a larger study with patients who have diabetic peripheral neuropathy.
超过3420万美国人患有糖尿病,每年用于糖尿病的直接费用为2370亿美元。其中,150亿美元仅用于足部溃疡治疗,因为超过一半的糖尿病患者会出现某种类型的神经病变,这是该人群中溃疡的主要可改变风险因素。目前,糖尿病周围神经病变(DPN)患者依赖于早期热点识别、垫底、卸载靴、糖尿病鞋,其依从性是主要问题。通过专家访谈,需要一种更好的方法来减缓和预防DPN患者的热点和其他并发症的进展。我们的团队正在提出一种可穿戴设备,用一种安全可行的刺激取代失去的疼痛感,通过改变步态来减轻疼痛。离散设计以患者、足科医生和血管外科医生的经验为指导,以提高患者的依从性、满意度和康复。早期的用户反馈证明了我们的设备可以改变健康参与者的行走行为,并有助于对糖尿病周围神经病变患者进行更大规模的研究。
{"title":"PREVENTING THE PROGRESSION OF DIABETIC FOOT ULCERS: ADDRESSING PATIENT COMPLIANCE WITH LOW-COST, BEHAVIOR-MODIFYING WEARABLES","authors":"Carine Rizk, Koby Reid, K. Tran, Hannah Bass","doi":"10.1115/dmd2023-7569","DOIUrl":"https://doi.org/10.1115/dmd2023-7569","url":null,"abstract":"\u0000 Over 34.2M Americans have diabetes and $237B is spent on direct costs of diabetes each year. Of this, $15B is spent on foot ulcer treatment alone as more than half of people with diabetes develop some type of neuropathy, the primary modifiable risk factor of ulcers in this population. Currently, patients with diabetic peripheral neuropathy (DPN) rely on early hotspot identification, padded soles, offloading boots, and diabetic shoes, with compliance being the major issue. Through expert interviews, there is a need for a better method to slow and prevent the progression of hot spots and other complications in patients with DPN. Our team is proposing DiaSense, a wearable device that replaces the lost sensation of pain with a safe and actionable stimulus that modifies gait to offload hotspots. The discrete design was guided by experiences from patients, podiatrists, and vascular surgeons to improve patient compliance, satisfaction, and recovery. Early user-feedback demonstrated useful validation that our device modifies walking behavior in healthy participants, and helps justify a larger study with patients who have diabetic peripheral neuropathy.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125844329","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A COMPLIANT FRACTURE FIXATION PLATE FOR CONTROLLED AXIAL MOTION IN LONG BONE HEALING 一种用于控制长骨轴向运动的柔性骨折固定钢板
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-8517
Connor Huxman, G. Lewis, Gary F. Updegrove, April D. Armstrong, Jared Butler
In this work, we introduce a novel compliant fracture fixation plate capable of delivering controlled axial micromotion to a diaphyseal fracture. When an appropriate amount of interfragmentary strain is achieved, this micromotion is known to facilitate secondary healing by callus formation. The proposed single-piece designs leverage mechanical compliance to achieve motion, eliminating friction, wear, and detailed assembly inherent to other multi-component concepts. 3-dimensional simulations are carried out under offset axial loading. Initial finite element analysis results suggest that flexure-based compliant plates can achieve increased magnitude and symmetry of axial interfragmentary strain, even when constructed of stainless steel, a surgeon-preferred material that traditionally may be too stiff to promote callus formation.
在这项工作中,我们介绍了一种新型柔性骨折固定板,能够为骨干骨折提供可控的轴向微运动。当达到适当数量的碎片间应变时,这种微运动被认为可以促进愈伤组织形成的二次愈合。提议的单件设计利用机械顺应性来实现运动,消除摩擦,磨损和其他多组件概念固有的详细组装。在轴向偏置载荷下进行了三维仿真。最初的有限元分析结果表明,基于挠曲的柔性钢板可以增加轴向碎片间应变的大小和对称性,即使是用不锈钢制成的,不锈钢是一种外科医生首选的材料,传统上可能过于僵硬,无法促进骨痂的形成。
{"title":"A COMPLIANT FRACTURE FIXATION PLATE FOR CONTROLLED AXIAL MOTION IN LONG BONE HEALING","authors":"Connor Huxman, G. Lewis, Gary F. Updegrove, April D. Armstrong, Jared Butler","doi":"10.1115/dmd2023-8517","DOIUrl":"https://doi.org/10.1115/dmd2023-8517","url":null,"abstract":"\u0000 In this work, we introduce a novel compliant fracture fixation plate capable of delivering controlled axial micromotion to a diaphyseal fracture. When an appropriate amount of interfragmentary strain is achieved, this micromotion is known to facilitate secondary healing by callus formation. The proposed single-piece designs leverage mechanical compliance to achieve motion, eliminating friction, wear, and detailed assembly inherent to other multi-component concepts. 3-dimensional simulations are carried out under offset axial loading. Initial finite element analysis results suggest that flexure-based compliant plates can achieve increased magnitude and symmetry of axial interfragmentary strain, even when constructed of stainless steel, a surgeon-preferred material that traditionally may be too stiff to promote callus formation.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130506382","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ON THE DESIGN OF ULTRA-WIDE BAND ANTIPODAL VIVALDI ANTENNA FOR BIOMEDICAL SENSORS 生物医学传感器用超宽带对映维瓦尔第天线的设计
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-2982
Poulami Samaddar, Tasin Nusrat, Sunil Gaddam, C. Leggett, S. Dey, Dipankar Mitra, Sayan Roy, S. P. Arunachalam
Designing an effective antenna is very important to utilize microwave imaging. A high gain antipodal antenna designed with ultra-wideband frequency range is presented here. The simulated results are validated with measured data. The antenna can operate within the Ultra band frequency range of 3 to 8 GHz. The maximum gain of 2.96 dBi is obtained at 4 GHz. An experiment with biological tissues is also done to show the effectiveness of the antenna using as a resonator.
设计有效的天线是利用微波成像的关键。本文设计了一种具有超宽带频率范围的高增益对映天线。仿真结果与实测数据相吻合。天线工作在3 ~ 8ghz的Ultra频段范围内。在4ghz时获得最大增益2.96 dBi。通过生物组织实验验证了该天线作为谐振器的有效性。
{"title":"ON THE DESIGN OF ULTRA-WIDE BAND ANTIPODAL VIVALDI ANTENNA FOR BIOMEDICAL SENSORS","authors":"Poulami Samaddar, Tasin Nusrat, Sunil Gaddam, C. Leggett, S. Dey, Dipankar Mitra, Sayan Roy, S. P. Arunachalam","doi":"10.1115/dmd2023-2982","DOIUrl":"https://doi.org/10.1115/dmd2023-2982","url":null,"abstract":"\u0000 Designing an effective antenna is very important to utilize microwave imaging. A high gain antipodal antenna designed with ultra-wideband frequency range is presented here. The simulated results are validated with measured data. The antenna can operate within the Ultra band frequency range of 3 to 8 GHz. The maximum gain of 2.96 dBi is obtained at 4 GHz. An experiment with biological tissues is also done to show the effectiveness of the antenna using as a resonator.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114961893","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
INITIAL COMPARISON OF VITAL SIGNS MONITORING ON THE WRIST WITH THE ANKLE AND BICEP 腕部与踝关节和肱二头肌生命体征监测的初步比较
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-6390
Sam Carlson, Farhanuddin Fazaluddin Kazi, Abigail R. Clarke-Sather, Jomara Sandbulte, Sonya Wang
Kangaroo care is a vital component of infant care that can lead to reduced morbidity and mortality amongst infants born prematurely. While it is known that kangaroo care, or more simply, skin-to-skin contact, can lead to better health outcomes for both the infant and the mother, the correlation between duration of kangaroo care and positive health outcomes remains a mystery. Not all mothers are able to perform kangaroo mother care, or 24-hour kangaroo care, so it is important to know how much kangaroo care is necessary to achieve positive health outcomes for infants born prematurely. To determine the relationship between maternal-infant interactions, a system of health monitoring devices is presented to measure the duration and frequency of kangaroo care, along with the effects of kangaroo care before, during, and after the act. One specific parameter of interest is the heartrate of the mother and infant. The maternal heartrate can be measured with a commercially available Garmin Venu® Sq smartwatch, but it typically cannot be worn on the wrist in NICUs due to their infection control guidelines. The viability of wearing a Garmin® smartwatch to measure maternal heartrate on the ankle or bicep compared to the wrist was determined by wearing three smartwatches simultaneously on the specified locations. It was found that the smartwatch located at the ankle undercounted the heartrate by an average of 0.5 bpm and the smartwatch located at the bicep overcounted by an average of 0.05 bpm. From statistical analysis, it was determined that the smartwatch worn at the bicep would be an acceptable alternative to wearing a smartwatch on the wrist to gather maternal heartrate data for use in the complete kangaroo care monitoring system.
袋鼠式护理是婴儿护理的重要组成部分,可以降低早产婴儿的发病率和死亡率。虽然我们知道袋鼠式护理,或者更简单地说,皮肤对皮肤的接触,可以为婴儿和母亲带来更好的健康结果,但袋鼠式护理的持续时间与积极的健康结果之间的相关性仍然是一个谜。并不是所有的母亲都能进行袋鼠式护理,或24小时袋鼠式护理,所以重要的是要知道多少袋鼠式护理是必要的,以实现早产儿的积极健康结果。为了确定母婴互动之间的关系,提出了一种健康监测设备系统,以测量袋鼠式护理的持续时间和频率,以及袋鼠式护理之前,期间和之后的效果。我们感兴趣的一个具体参数是母亲和婴儿的心率。产妇心率可以用市售的Garmin Venu®Sq智能手表测量,但由于感染控制指南的限制,在新生儿重症监护病房,它通常不能戴在手腕上。通过在指定位置同时佩戴三块智能手表来确定佩戴Garmin®智能手表测量踝关节或肱二头肌与手腕心率的可行性。结果发现,脚踝处的智能手表平均少记0.5 bpm,二头肌处的智能手表平均多记0.05 bpm。通过统计分析,确定佩戴在二头肌处的智能手表可以替代佩戴在手腕上的智能手表来收集产妇心率数据,用于完整的袋鼠护理监测系统。
{"title":"INITIAL COMPARISON OF VITAL SIGNS MONITORING ON THE WRIST WITH THE ANKLE AND BICEP","authors":"Sam Carlson, Farhanuddin Fazaluddin Kazi, Abigail R. Clarke-Sather, Jomara Sandbulte, Sonya Wang","doi":"10.1115/dmd2023-6390","DOIUrl":"https://doi.org/10.1115/dmd2023-6390","url":null,"abstract":"\u0000 Kangaroo care is a vital component of infant care that can lead to reduced morbidity and mortality amongst infants born prematurely. While it is known that kangaroo care, or more simply, skin-to-skin contact, can lead to better health outcomes for both the infant and the mother, the correlation between duration of kangaroo care and positive health outcomes remains a mystery. Not all mothers are able to perform kangaroo mother care, or 24-hour kangaroo care, so it is important to know how much kangaroo care is necessary to achieve positive health outcomes for infants born prematurely. To determine the relationship between maternal-infant interactions, a system of health monitoring devices is presented to measure the duration and frequency of kangaroo care, along with the effects of kangaroo care before, during, and after the act. One specific parameter of interest is the heartrate of the mother and infant. The maternal heartrate can be measured with a commercially available Garmin Venu® Sq smartwatch, but it typically cannot be worn on the wrist in NICUs due to their infection control guidelines. The viability of wearing a Garmin® smartwatch to measure maternal heartrate on the ankle or bicep compared to the wrist was determined by wearing three smartwatches simultaneously on the specified locations. It was found that the smartwatch located at the ankle undercounted the heartrate by an average of 0.5 bpm and the smartwatch located at the bicep overcounted by an average of 0.05 bpm. From statistical analysis, it was determined that the smartwatch worn at the bicep would be an acceptable alternative to wearing a smartwatch on the wrist to gather maternal heartrate data for use in the complete kangaroo care monitoring system.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"149 11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130150309","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
“EXTENSOR” SOFT ROBOT FOR CLENCHED FIST REHABILITATION AFTER STROKE 用于中风后握拳康复的“伸肌”软机器人
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-4176
Matthew Baysa, Noah Turoski, Manilyn Cabrera, Yen-Lin Han
Stroke is a leading cause of mobility impairments. As more people suffer from stroke, there is a growing need for rehabilitation. Rehabilitation robots have been proven effective in assisting patients in their rehabilitation process. However, many existing rehabilitation robots are costly, so the accessibility to patients in need is limited. Soft robot technology has great potential to make rehabilitation more accessible. This paper presents a proof-of-concept soft robot design that could be used for finger rehabilitation, especially for those who suffer from clenched fists after a stroke. Using silicone elastomer and pneumatic actuation, we successfully fabricated a soft robot that curled in its resting state to fit under the patient’s clenched fist and straightened when actuated by compressed air to push the patient’s fingers open. With a unique approach to bonding the two-layer silicone elastomer structure, our soft robot can change shape to straight from its original curling state with a small air pressure (2 to 3 psi). Preliminary testing results demonstrate our soft robot’s functionality and provide valuable insights for us to optimize our design further to reach our eventual goal as a rehabilitation device that assists finger rehabilitation.
中风是导致行动障碍的主要原因。随着越来越多的人患中风,对康复的需求也越来越大。康复机器人在帮助患者康复过程中已经被证明是有效的。然而,许多现有的康复机器人都是昂贵的,所以有需要的病人的可及性是有限的。软机器人技术有很大的潜力使康复更容易实现。本文提出了一种概念验证软机器人设计,可用于手指康复,特别是那些中风后拳头紧握的人。利用硅胶弹性体和气动驱动,我们成功地制造了一个软体机器人,它在静止状态下卷曲以适应患者握紧的拳头,在压缩空气驱动下伸直以推动患者的手指张开。通过一种独特的方法将两层有机硅弹性体结构粘合在一起,我们的软体机器人可以在很小的气压(2到3 psi)下从原来的卷曲状态改变形状。初步的测试结果证明了我们的软体机器人的功能,并为我们进一步优化设计提供了有价值的见解,以实现我们作为辅助手指康复的康复设备的最终目标。
{"title":"“EXTENSOR” SOFT ROBOT FOR CLENCHED FIST REHABILITATION AFTER STROKE","authors":"Matthew Baysa, Noah Turoski, Manilyn Cabrera, Yen-Lin Han","doi":"10.1115/dmd2023-4176","DOIUrl":"https://doi.org/10.1115/dmd2023-4176","url":null,"abstract":"\u0000 Stroke is a leading cause of mobility impairments. As more people suffer from stroke, there is a growing need for rehabilitation. Rehabilitation robots have been proven effective in assisting patients in their rehabilitation process. However, many existing rehabilitation robots are costly, so the accessibility to patients in need is limited. Soft robot technology has great potential to make rehabilitation more accessible. This paper presents a proof-of-concept soft robot design that could be used for finger rehabilitation, especially for those who suffer from clenched fists after a stroke. Using silicone elastomer and pneumatic actuation, we successfully fabricated a soft robot that curled in its resting state to fit under the patient’s clenched fist and straightened when actuated by compressed air to push the patient’s fingers open. With a unique approach to bonding the two-layer silicone elastomer structure, our soft robot can change shape to straight from its original curling state with a small air pressure (2 to 3 psi). Preliminary testing results demonstrate our soft robot’s functionality and provide valuable insights for us to optimize our design further to reach our eventual goal as a rehabilitation device that assists finger rehabilitation.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128614663","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
DESIGN AND EVALUATION OF A SYSTEM FOR CT-FREE VOLUME RECONSTRUCTION FROM INTRA-OPERATIVE FLUOROSCOPY FOR NAVIGATION IN ORTHOPEDIC SURGERY 骨科手术中导航用术中透视无ct容积重建系统的设计与评估
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-9640
Marcus Tatum, G. Thomas, D. Anderson
A novel biomechanical guidance system (BGS) for markerless intra-operative bone tracking that seamlessly integrates into the surgical setting was recently developed [1]. It utilizes 3D models from pre-operative CT, via 3D-to-2D registration methods, to update object poses based on 2D fluoroscopic images. However, on occasion pre-operative CT images may be unavailable. We developed a CT-free method to enable BGS use that leverages neural radiance fields (NeRF) to generate a continuous volumetric scene [2,3] from intra-operative fluoroscopy. For proof of concept, digitally reconstructed radiographs (DRRs) were created from pelvic CT data as a stand-in for intra-operative fluoroscopy. DRRs and virtual C-arm positions were fed into an existing NeRF scene reconstruction system,[2,3] and bones were segmented from the reconstruction. The accuracy of NeRF-derived segmentations was evaluated by comparison to gold-standard CT segmentation. The number of input DRRs was varied to study how this parameter influences reconstructions. Volume reconstructions were readily obtained using the NeRF scene reconstruction system. RMS errors of the NeRF-derived segmentations ranged from 1.23 mm when using 36 input DRR images to 1.98 mm when using only 8 input DRR images. Based on this performance, we conclude that CT-free NeRF volume reconstruction from intra-operative fluoroscopy holds great potential for use in surgical navigation applications involving bony procedures.
最近开发了一种新的生物力学引导系统(BGS),用于术中无标记骨跟踪,无缝集成到手术环境中[1]。它利用术前CT的3D模型,通过3D到2D的配准方法,根据2D透视图像更新物体姿态。然而,有时术前CT图像可能不可用。我们开发了一种无需ct的BGS使用方法,利用神经辐射场(NeRF)从术中透视产生连续的体积场景[2,3]。为了证明这一概念,从骨盆CT数据创建了数字重建x线片(DRRs),作为术中透视检查的替代品。将DRRs和虚拟c臂位置输入到现有的NeRF场景重建系统中,[2,3]并从重建中分割骨骼。通过与金标准CT分割的比较,评估了nerf衍生分割的准确性。通过改变输入drr的数量来研究该参数对重建的影响。使用NeRF场景重建系统可以很容易地获得体重建。在使用36张输入DRR图像时,nerf衍生分割的均方根误差为1.23 mm,而仅使用8张输入DRR图像时,其均方根误差为1.98 mm。基于这一表现,我们得出结论,术中透视无ct NeRF体积重建在涉及骨手术的外科导航应用中具有巨大的潜力。
{"title":"DESIGN AND EVALUATION OF A SYSTEM FOR CT-FREE VOLUME RECONSTRUCTION FROM INTRA-OPERATIVE FLUOROSCOPY FOR NAVIGATION IN ORTHOPEDIC SURGERY","authors":"Marcus Tatum, G. Thomas, D. Anderson","doi":"10.1115/dmd2023-9640","DOIUrl":"https://doi.org/10.1115/dmd2023-9640","url":null,"abstract":"\u0000 A novel biomechanical guidance system (BGS) for markerless intra-operative bone tracking that seamlessly integrates into the surgical setting was recently developed [1]. It utilizes 3D models from pre-operative CT, via 3D-to-2D registration methods, to update object poses based on 2D fluoroscopic images. However, on occasion pre-operative CT images may be unavailable. We developed a CT-free method to enable BGS use that leverages neural radiance fields (NeRF) to generate a continuous volumetric scene [2,3] from intra-operative fluoroscopy. For proof of concept, digitally reconstructed radiographs (DRRs) were created from pelvic CT data as a stand-in for intra-operative fluoroscopy. DRRs and virtual C-arm positions were fed into an existing NeRF scene reconstruction system,[2,3] and bones were segmented from the reconstruction. The accuracy of NeRF-derived segmentations was evaluated by comparison to gold-standard CT segmentation. The number of input DRRs was varied to study how this parameter influences reconstructions. Volume reconstructions were readily obtained using the NeRF scene reconstruction system. RMS errors of the NeRF-derived segmentations ranged from 1.23 mm when using 36 input DRR images to 1.98 mm when using only 8 input DRR images. Based on this performance, we conclude that CT-free NeRF volume reconstruction from intra-operative fluoroscopy holds great potential for use in surgical navigation applications involving bony procedures.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120931915","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
BAILOUT POST-TAVR PCI TECHNIQUES IN REANIMATED SWINE AND HUMAN HEARTS: PROCEDURAL IMAGING AND POST-PROCEDURAL MODELING TECHNIQUES 救助后tavr pci技术在复活猪和人的心脏:程序成像和后程序建模技术
Pub Date : 2023-04-17 DOI: 10.1115/dmd2023-2988
Michael A. Bielecki, A. DeVos, P. Iaizzo
Transcatheter aortic valve replacement (TAVR) has become a popular treatment option for severe aortic stenosis (AS) patients who present a high risk for mortality should they receive a surgical aortic valve replacement (SAVR). Coronary artery occlusion (CAO) following the implantation of the device is a potential complication with a high mortality rate, as CAO causes a deterioration of coronary perfusion, followed by cardiogenic shock and electrical instability. Due to this dangerous potential complication, bailout percutaneous coronary intervention (PCI) techniques, like the snorkel and chimney techniques, have been developed as an effective strategy for ensuring coronary perfusion is maintained following a TAVR procedure. Both snorkel and chimney techniques have been implemented in a reanimated swine and human heart respectively utilizing Visible Heart® methodologies. The procedures have been recorded utilizing endoscopic cameras, echocardiography, optical coherence tomography, and fluoroscopy. Post-procedural micro-computed tomography (micro-CT) was conducted to provide post-implantation imaging with approximately 60-micron resolution. The reconstructions are then segmented and used to create 3D renderings of these complex procedures. These methodologies are repeatable and can be used in a variety of conditions to be used in subsequent educational uses.
经导管主动脉瓣置换术(TAVR)已成为严重主动脉瓣狭窄(AS)患者的一种流行治疗选择,这些患者如果接受手术主动脉瓣置换术(SAVR),死亡风险很高。植入该装置后的冠状动脉闭塞(CAO)是一个潜在的并发症,死亡率很高,因为CAO会导致冠状动脉灌注恶化,随后是心源性休克和电不稳定。由于这种危险的潜在并发症,紧急经皮冠状动脉介入治疗(PCI)技术,如通气管和烟囱技术,已经发展成为确保TAVR手术后冠状动脉灌注维持的有效策略。通气管和烟囱技术已经分别应用Visible heart®方法在复活猪和人的心脏中实施。使用内窥镜、超声心动图、光学相干断层扫描和透视记录了手术过程。术后进行显微计算机断层扫描(micro-CT),提供约60微米分辨率的植入后成像。然后将重建分割并用于创建这些复杂程序的3D渲染。这些方法是可重复的,可以在各种条件下用于后续的教育用途。
{"title":"BAILOUT POST-TAVR PCI TECHNIQUES IN REANIMATED SWINE AND HUMAN HEARTS: PROCEDURAL IMAGING AND POST-PROCEDURAL MODELING TECHNIQUES","authors":"Michael A. Bielecki, A. DeVos, P. Iaizzo","doi":"10.1115/dmd2023-2988","DOIUrl":"https://doi.org/10.1115/dmd2023-2988","url":null,"abstract":"\u0000 Transcatheter aortic valve replacement (TAVR) has become a popular treatment option for severe aortic stenosis (AS) patients who present a high risk for mortality should they receive a surgical aortic valve replacement (SAVR). Coronary artery occlusion (CAO) following the implantation of the device is a potential complication with a high mortality rate, as CAO causes a deterioration of coronary perfusion, followed by cardiogenic shock and electrical instability. Due to this dangerous potential complication, bailout percutaneous coronary intervention (PCI) techniques, like the snorkel and chimney techniques, have been developed as an effective strategy for ensuring coronary perfusion is maintained following a TAVR procedure. Both snorkel and chimney techniques have been implemented in a reanimated swine and human heart respectively utilizing Visible Heart® methodologies. The procedures have been recorded utilizing endoscopic cameras, echocardiography, optical coherence tomography, and fluoroscopy. Post-procedural micro-computed tomography (micro-CT) was conducted to provide post-implantation imaging with approximately 60-micron resolution. The reconstructions are then segmented and used to create 3D renderings of these complex procedures. These methodologies are repeatable and can be used in a variety of conditions to be used in subsequent educational uses.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134021084","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
2023 Design of Medical Devices Conference
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1