{"title":"Inductive coupled-coils angle encoders with improved performance and linearity","authors":"R. Dauth, G. Gerlach, S. Fella","doi":"10.1515/teme-2023-0068","DOIUrl":"https://doi.org/10.1515/teme-2023-0068","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88874343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Schneider, Tanja Dorst, C. Schnur, P. Goodarzi, A. Schütze
{"title":"Einfluss von Datenqualität, Domain Shift und Messunsicherheit auf die Vorhersagequalität smarter Sensorsysteme","authors":"T. Schneider, Tanja Dorst, C. Schnur, P. Goodarzi, A. Schütze","doi":"10.1515/teme-2023-0087","DOIUrl":"https://doi.org/10.1515/teme-2023-0087","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89069939","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Entwicklung eines nephrologisch optischen Messverfahrens zur Bestimmung von Partikelkonzentrationen in Gasen und Flüssigkeiten hinter lichtstreuenden Kunststoffwandungen","authors":"Hamed Elahi, E. Manske, U. Gerhardt","doi":"10.1515/teme-2023-0070","DOIUrl":"https://doi.org/10.1515/teme-2023-0070","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91012841","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Diametrical optical coherence tomography for extended depth measurement range","authors":"E. Hachgenei, Maria Vakaeva, R. H. Schmitt","doi":"10.1515/teme-2023-0072","DOIUrl":"https://doi.org/10.1515/teme-2023-0072","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83704104","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of turbulence parameters with a multipoint Laser Doppler Vibrometer","authors":"Kristina Tolchkova, C. Rembe","doi":"10.1515/teme-2023-0076","DOIUrl":"https://doi.org/10.1515/teme-2023-0076","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72995124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Thomas Schaechtle, H. Köhler, Jan Helmerich, G. Fischer, Antonio Gabbrielli, Fabian Höflinger, S. Rupitsch
{"title":"Energieeffiziente akustische Kommunikation durch Metall für drahtlose Sensoranwendungen","authors":"Thomas Schaechtle, H. Köhler, Jan Helmerich, G. Fischer, Antonio Gabbrielli, Fabian Höflinger, S. Rupitsch","doi":"10.1515/teme-2023-0077","DOIUrl":"https://doi.org/10.1515/teme-2023-0077","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78909775","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Herzog, M. Rio, C. Schuster, T. Härtling, G. Gerlach
Zusammenfassung Brechzahlsensitive plasmonische Sensoren mit nanostrukturierten Goldoberflächen bieten viele Vorteile für die kontinuierliche Vor-Ort-Überwachung in komplexen Prozessflüssigkeiten. In Kombination mit stimulus-responsiven Hydrogelen haben diese Potential für die selektive Detektion von Einzelparametern, hier der Ethanolkonzentration, bei sich gleichzeitig ändernden Stoffkonzentrationen anderer Komponenten. Ein erster Schritt zur Ausnutzung dieser selektiven Eigenschaften ist die Differenzierung des ethanolinduzierten Quelleffekts im eingesetzten Polyacrylamid-Hydrogel von der Brechzahländerung der zu analysierenden Flüssigkeit in Folge von Konzentrationsänderungen. Dies wurde durch die Anwendung einer mit Hydrogel funktionalisierten Messfläche und einer nicht funktionalisierten Referenzfläche erreicht. Das hier vorgestellte Sensorkonzept ermöglicht so die Bestimmung der Ethanolkonzentration wässriger Lösungen zwischen 40 und 60 vol%. Dabei wird gezeigt, dass von der Entquellung des Hydrogelvolumens nicht direkt auf das oberflächennahe Verhalten geschlossen werden kann, sondern eine individuelle Kalibrierung des optischen Signals notwendig ist.
来自纳米管金壁的吐感电传感器摘要对复杂过程中的现场监测具有很多优势。在刺激反应液基的作用下,这有可能在单一参数(乙烷)中选择性测出。在乙烷含量不同的时候,其他成分的频率也不同。利用这些伐木特性的第一步是利用所使用聚向丙烯溶液的碳酸水与分析液体的衰减产生作用。这一结果是利用水蛭效应测量区域和非功能参考层实现的。在这里想象Sensorkonzept允许指定Ethanolkonzentration wässriger解决四十至六十 parts % .。研究表明,释放水的流量并不能直接稳定在表面的行为上,而是需要针对可见信号进行个体校正。
{"title":"Hydrogelbasierte plasmonische Sensoren zur Ethanoldetektion: Einfluss des Quellverhaltens auf das optische Signal","authors":"J. Herzog, M. Rio, C. Schuster, T. Härtling, G. Gerlach","doi":"10.1515/teme-2023-0081","DOIUrl":"https://doi.org/10.1515/teme-2023-0081","url":null,"abstract":"Zusammenfassung Brechzahlsensitive plasmonische Sensoren mit nanostrukturierten Goldoberflächen bieten viele Vorteile für die kontinuierliche Vor-Ort-Überwachung in komplexen Prozessflüssigkeiten. In Kombination mit stimulus-responsiven Hydrogelen haben diese Potential für die selektive Detektion von Einzelparametern, hier der Ethanolkonzentration, bei sich gleichzeitig ändernden Stoffkonzentrationen anderer Komponenten. Ein erster Schritt zur Ausnutzung dieser selektiven Eigenschaften ist die Differenzierung des ethanolinduzierten Quelleffekts im eingesetzten Polyacrylamid-Hydrogel von der Brechzahländerung der zu analysierenden Flüssigkeit in Folge von Konzentrationsänderungen. Dies wurde durch die Anwendung einer mit Hydrogel funktionalisierten Messfläche und einer nicht funktionalisierten Referenzfläche erreicht. Das hier vorgestellte Sensorkonzept ermöglicht so die Bestimmung der Ethanolkonzentration wässriger Lösungen zwischen 40 und 60 vol%. Dabei wird gezeigt, dass von der Entquellung des Hydrogelvolumens nicht direkt auf das oberflächennahe Verhalten geschlossen werden kann, sondern eine individuelle Kalibrierung des optischen Signals notwendig ist.","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78445771","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Photoakustische Interferometrie für Gaskonzentrationsmessungen","authors":"M. Hoffmann, Zongze Jiang, Alexander W. Koch","doi":"10.1515/teme-2023-0083","DOIUrl":"https://doi.org/10.1515/teme-2023-0083","url":null,"abstract":"","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":1.0,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82968078","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}