首页 > 最新文献

Al-Kitab Journal for Pure Sciences最新文献

英文 中文
The Comparison of Retention between Hot Curing andFluid Denture Base Acrylic Resin(In Vivo) 热固化与液体基托丙烯酸树脂固位的体内比较
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p10
Bestun Akram, R. Hasan
Adequate retention is a basic requirement for the acceptance of complete denture. The aim of this study was to evaluate the retention quality of fluid denture base materials and compare it with conventional acrylic denture base materials Method: Sixteen edentulous male patients with an age 45-60 years participated in the study. For each patient two denture bases were constructed, one of them made from fluid denture basematerials and the other made from hot acrylic denture base materials. A specially designed strain gauge measuring device was used to measure the force required to dislodge the two dentures from basal seats. Six measurements of retention of newly inserted denture base were recorded for each patient (three for maxillary acrylic denture base and three for maxillary fluid denture base). Results: The results of the retention test showed that the fluid denture base materials required more force in order to dislodge denture than the heat cure denture base materials, which means a significant improvement in retention quality obtained by fluid denture base materials. Conclusions: It has appeared that the fluid acrylic denture base materials produce denture basematerial with excellent retentive efficiency to the underlying tissue when compared toconventional denture base materials.
充分固位是接受全口义齿的基本要求。本研究的目的是评价液体义齿基托材料的固位质量,并与常规丙烯酸义齿基托材料进行比较。方法:选取16例年龄45-60岁的无牙男性患者进行研究。为每位患者制作两个义齿基托,一个由液体义齿基托材料制作,另一个由热丙烯酸义齿基托材料制作。使用特殊设计的应变计测量装置来测量将两个义齿从基托上移除所需的力。每位患者记录了6次新插入义齿基托固位测量(上颌丙烯酸基托3次,上颌液体基托3次)。结果:固位试验结果显示,液态义齿基托材料比热固化义齿基托材料需要更大的力才能将义齿移出,这说明液态义齿基托材料获得的固位质量有明显提高。结论:液体丙烯酸义齿基托材料与常规义齿基托材料相比,具有良好的固位效果。
{"title":"The Comparison of Retention between Hot Curing and\u0000Fluid Denture Base Acrylic Resin\u0000(In Vivo)","authors":"Bestun Akram, R. Hasan","doi":"10.32441/kjps.02.02.p10","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p10","url":null,"abstract":"Adequate retention is a basic requirement for the acceptance of complete denture. The aim of this study was to evaluate the retention quality of fluid denture base materials and compare it with conventional acrylic denture base materials Method: Sixteen edentulous male patients with an age 45-60 years participated in the study. For each patient two denture bases were constructed, one of them made from fluid denture base\u0000materials and the other made from hot acrylic denture base materials. A specially designed strain gauge measuring device was used to measure the force required to dislodge the two dentures from basal seats. Six measurements of retention of newly inserted denture base were recorded for each patient (three for maxillary acrylic denture base and three for maxillary fluid denture base). Results: The results of the retention test showed that the fluid denture base materials required more force in order to dislodge denture than the heat cure denture base materials, which means a significant improvement in retention quality obtained by fluid denture base materials. Conclusions: It has appeared that the fluid acrylic denture base materials produce denture base\u0000material with excellent retentive efficiency to the underlying tissue when compared to\u0000conventional denture base materials.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"76 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89141735","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Addition Of Zirconium Oxide Nanoparticles onFlexural Strength and Porosity of Heat Cure AcrylicResin 纳米氧化锆的加入对热固化丙烯酸树脂抗弯强度和孔隙率的影响
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p7
Ranj A. Omer, Fahd S. Ikram
Heat cure denture base is the most commonly used material for fabrication of removable prosthesis to the present day. However difficulties persist in fabrication of satisfactory prosthesis due to poor mechanical properties which have resulted in frequent repairs in dental practice. The present study is aimed to investigate the effect of Zirconium oxide nanoparticles (ZrO2NPs) on flexural strength and porosity of denture base and its correlation. X-ray diffraction (XRD) was used to check the purity of NPs. NPs was dispersed at 1%, 3% and 5% by weight to the monomer of methyl methacrylate with aid of probe sonicator. In addition, Scanning Electron Microscope (SEM) was used to observe agglomeration of particles within the acrylic. The results revealed significant flexural strength difference (p<0.05) between each concentration of ZrO2NPs. The analysis showed 17% and 11% reduction for 1% and 3% ZrO2NPs respectively while 5% caused a drastic reduction by 32% in reference to control. In regards to porosity, the results present no statistically significant difference among the concentrations in contrast to control. Pearson correlation showed strong and a negative relation (-0.83) between flexural strength and porosity. However, the results was not statistically significant (p=0.369). Within the limitations of this study, it can be concluded that the addition of ZrO2 caused reduction in flexural strength for all concentrations added. While it caused non-significant effect on porosity of acrylic. suitable additive to enhance the properties of PMMA.
热固化义齿基托是目前制作活动义齿最常用的材料。然而,由于假体的机械性能较差,导致在牙科实践中经常进行修复,因此制造令人满意的假体仍然存在困难。本研究旨在探讨氧化锆纳米颗粒(ZrO2NPs)对义齿基托抗弯强度和孔隙度的影响及其相关性。用x射线衍射(XRD)检测了NPs的纯度。将NPs以1%、3%和5%的重量分散到甲基丙烯酸甲酯单体上。此外,用扫描电子显微镜(SEM)观察了丙烯酸酯内部颗粒的团聚情况。结果表明,不同浓度ZrO2NPs的抗弯强度差异显著(p<0.05)。分析表明,1%和3%的ZrO2NPs分别减少了17%和11%,而5%的ZrO2NPs与对照相比减少了32%。在孔隙度方面,不同浓度的结果与对照组相比无统计学差异。抗折强度与孔隙率呈显著负相关(-0.83)。但结果无统计学意义(p=0.369)。在本研究的限制范围内,可以得出结论,添加ZrO2会导致所有添加浓度的抗弯强度降低。而对丙烯酸树脂的孔隙率影响不显著。合适的添加剂来提高PMMA的性能。
{"title":"Effect of Addition Of Zirconium Oxide Nanoparticles on\u0000Flexural Strength and Porosity of Heat Cure Acrylic\u0000Resin","authors":"Ranj A. Omer, Fahd S. Ikram","doi":"10.32441/kjps.02.02.p7","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p7","url":null,"abstract":"Heat cure denture base is the most commonly used material for fabrication of removable prosthesis to the present day. However difficulties persist in fabrication of satisfactory prosthesis due to poor mechanical properties which have resulted in frequent repairs in dental practice. The present study is aimed to investigate the effect of Zirconium oxide nanoparticles (ZrO2NPs) on flexural strength and porosity of denture base and its correlation. X-ray diffraction (XRD) was used to check the purity of NPs. NPs was dispersed at 1%, 3% and 5% by weight to the monomer of methyl methacrylate with aid of probe sonicator. In addition, Scanning Electron Microscope (SEM) was used to observe agglomeration of particles within the acrylic. The results revealed significant flexural strength difference (p<0.05) between each concentration of ZrO2NPs. The analysis showed 17% and 11% reduction for 1% and 3% ZrO2NPs respectively while 5% caused a drastic reduction by 32% in reference to control. In regards to porosity, the results present no statistically significant difference among the concentrations in contrast to control. Pearson correlation showed strong and a negative relation (-0.83) between flexural strength and porosity. However, the results was not statistically significant (p=0.369). Within the limitations of this study, it can be concluded that the addition of ZrO2 caused reduction in flexural strength for all concentrations added. While it caused non-significant effect on porosity of acrylic. suitable additive to enhance the properties of PMMA.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"326 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77123165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Hybrid Algorithm Between the Artificial ImmunologicalNetwork and the ANFIS Technique with Application 人工免疫网络与ANFIS技术的混合算法及其应用
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p22
Omar S. Kasim, Israa Alkhayyat
the Artificial Immune Network, was developed using the Adaptive Neuro FuzzyInference System (ANFIS) by using the Immune Memory, The immunological network as aninput to ANFIS technology to increase the chance of training a model based on the pattern of simulation of data patterns, as the immune memory resulting from the immunologicalnetwork makes copies of data with characteristics similar to the original data. The proposed algorithm proved to have better and more efficient results rack on the patterns compared with the usual artificial immune system.
人工免疫网络,是利用自适应神经模糊会议系统(ANFIS)利用免疫记忆开发的,免疫网络作为ANFIS技术的输入,增加了基于数据模式模拟模式的模型训练的机会,因为免疫网络产生的免疫记忆会复制具有与原始数据相似特征的数据。与传统的人工免疫系统相比,该算法具有更好、更高效的模式检测结果。
{"title":"A Hybrid Algorithm Between the Artificial Immunological\u0000Network and the ANFIS Technique with Application","authors":"Omar S. Kasim, Israa Alkhayyat","doi":"10.32441/kjps.02.02.p22","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p22","url":null,"abstract":"the Artificial Immune Network, was developed using the Adaptive Neuro Fuzzy\u0000Inference System (ANFIS) by using the Immune Memory, The immunological network as an\u0000input to ANFIS technology to increase the chance of training a model based on the pattern of simulation of data patterns, as the immune memory resulting from the immunological\u0000network makes copies of data with characteristics similar to the original data. The proposed algorithm proved to have better and more efficient results rack on the patterns compared with the usual artificial immune system.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"43 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74719641","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Candida spp Complications in Acute Myeloid Leukemia Patients in Erbil City 埃尔比勒市急性髓系白血病患者念珠菌并发症
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p4
P. A. Hamsaeed, A. Muhammad
This study has been carried out in Erbil City -Iraq, 30 patients were diagnosis by flowcytometry as AML which they were admitted to Nanakaly Hospital for Blood Disease andsubmitted to chemotherapy. Number of adults/children 22 (73.3%) / 8 (26.7%), female /male 13 (43.3%) / 17(56.7%). Only 20 (66.7%) patients were smoker. The highest numberwas subtyping M4 10 (33.3%) patients, followed by M1 7(23.3%), M3 6(20%), M2 were3(10%) patients. M5 and M6 were 2 (6.7%). Ten candida spp isolates before induction phasechemotherapy show 9(90%) C.albicans, 1(10%) C. lusitaniae, and from 32 isolates afterinduction phase chemotherapy, 17(53.1%) C.albicans, 7(21.9%) C. lusitaniae, and 8(25%)C.famata. According to the site of infection, before starting chemotherapy 8(88.9%) C.albicans isolates were in the oral cavity and 1(11.1%) on the skin, while C. lusitaniae was 1 (100%) in oral cavity only. While after chemotherapy 12(70.6%) C.albicans in the oralcavity and 5(29.4%) on the skin, C. lusitaniae was 2 (28.6%) in the oral cavity and 5(71.4%) on the skin, while all C. famata was 8 (100%) on the skinThe immunophenotype shows that the number and percentage of patients which the myeloid cells expressed cyMPO was 27(90) with mean percentage of positivity 59.38, while all patients expressed CD33 and CD13 on their blast cell 30(100) with a mean percentage of positivity 59.81 and 30.83 respectively.
本研究在伊拉克埃尔比勒市进行,30例患者经流式细胞术诊断为急性髓细胞白血病,他们被送入Nanakaly血液病医院并接受化疗。成人/儿童22(73.3%)/ 8(26.7%),女性/男性13(43.3%)/ 17(56.7%)。仅20例(66.7%)为吸烟者。其中以M4 10例(33.3%)最多,其次为M1 7例(23.3%)、M3 6例(20%)、M2 3例(10%)。M5、M6 2例(6.7%)。诱导期化疗前分离的10株念珠菌中,白色念珠菌9株(90%),卢西塔念珠菌1株(10%);诱导期化疗后分离的32株中,白色念珠菌17株(53.1%),卢西塔念珠菌7株(21.9%),famata念珠菌8株(25%)。按感染部位分,化疗前口腔白色念珠菌8株(88.9%),皮肤念珠菌1株(11.1%),仅口腔念珠菌1株(100%)。化疗后口腔白色念珠菌12例(70.6%),皮肤5例(29.4%),卢西顿念珠菌2例(28.6%),皮肤5例(71.4%),皮肤全部念珠菌8例(100%)。免疫表型显示骨髓细胞表达cyMPO的患者数量和百分比为27例(90),平均阳性百分比为59.38。所有患者在其母细胞30(100)上均表达CD33和CD13,平均阳性率分别为59.81和30.83。
{"title":"Candida spp Complications in Acute Myeloid Leukemia Patients in Erbil City","authors":"P. A. Hamsaeed, A. Muhammad","doi":"10.32441/kjps.02.02.p4","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p4","url":null,"abstract":"This study has been carried out in Erbil City -Iraq, 30 patients were diagnosis by flow\u0000cytometry as AML which they were admitted to Nanakaly Hospital for Blood Disease and\u0000submitted to chemotherapy. Number of adults/children 22 (73.3%) / 8 (26.7%), female /\u0000male 13 (43.3%) / 17(56.7%). Only 20 (66.7%) patients were smoker. The highest number\u0000was subtyping M4 10 (33.3%) patients, followed by M1 7(23.3%), M3 6(20%), M2 were\u00003(10%) patients. M5 and M6 were 2 (6.7%). Ten candida spp isolates before induction phase\u0000chemotherapy show 9(90%) C.albicans, 1(10%) C. lusitaniae, and from 32 isolates after\u0000induction phase chemotherapy, 17(53.1%) C.albicans, 7(21.9%) C. lusitaniae, and 8(25%)\u0000C.famata. According to the site of infection, before starting chemotherapy 8(88.9%) C.\u0000albicans isolates were in the oral cavity and 1(11.1%) on the skin, while C. lusitaniae was 1 (100%) in oral cavity only. While after chemotherapy 12(70.6%) C.albicans in the oral\u0000cavity and 5(29.4%) on the skin, C. lusitaniae was 2 (28.6%) in the oral cavity and 5(71.4%) on the skin, while all C. famata was 8 (100%) on the skin\u0000The immunophenotype shows that the number and percentage of patients which the myeloid cells expressed cyMPO was 27(90) with mean percentage of positivity 59.38, while all patients expressed CD33 and CD13 on their blast cell 30(100) with a mean percentage of positivity 59.81 and 30.83 respectively.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"68 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85799173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Environmental Pollution of Cellular Mobile Base Stationin Populated Areas 人口密集地区蜂窝移动基站的环境污染
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p5
Radhi Isa Sahan, Haider Easa, A. Sallomi
Cellular mobile communication technology has grown exponentially in the lastdecade resulting in large number of base stations in areas at which people are living orworking. All over the world, the electromagnetic pollution produced from cellular basestations erected in residential areas and its effect on the environment and human body is a problem that has been concerning the society for many years. This paper, introduces the effects of electromagnetic energy emitted cellular base stations on the biological systems of the human body. The induced electromagnetic fields (EMF), and specific absorption rate (SAR) were calculated in close proximity to cellular mobile base stations. The calculated values of SAR were compared with the most commonly used international limits. The results show that the electromagnetic radiation (EMR) exposure levels at a distance of several meters from the base station towers can cause hazardous effects to the public.
蜂窝移动通信技术在过去十年中呈指数级增长,在人们生活或工作的地区产生了大量的基站。在世界范围内,住宅小区蜂窝基站产生的电磁污染及其对环境和人体的影响是一个多年来备受社会关注的问题。本文介绍了蜂窝基站发射的电磁能量对人体生物系统的影响。在蜂窝移动基站附近计算了感应电磁场(EMF)和比吸收率(SAR)。将SAR计算值与最常用的国际限值进行比较。结果表明,距离基站塔数米的电磁辐射暴露水平会对公众造成危害。
{"title":"Environmental Pollution of Cellular Mobile Base Station\u0000in Populated Areas","authors":"Radhi Isa Sahan, Haider Easa, A. Sallomi","doi":"10.32441/kjps.02.02.p5","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p5","url":null,"abstract":"Cellular mobile communication technology has grown exponentially in the last\u0000decade resulting in large number of base stations in areas at which people are living or\u0000working. All over the world, the electromagnetic pollution produced from cellular base\u0000stations erected in residential areas and its effect on the environment and human body is a problem that has been concerning the society for many years. This paper, introduces the effects of electromagnetic energy emitted cellular base stations on the biological systems of the human body. The induced electromagnetic fields (EMF), and specific absorption rate (SAR) were calculated in close proximity to cellular mobile base stations. The calculated values of SAR were compared with the most commonly used international limits. The results show that the electromagnetic radiation (EMR) exposure levels at a distance of several meters from the base station towers can cause hazardous effects to the public.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83018217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An Enhancement of Simultaneous Localization and Mapping Model Using Artificial Neural Networks 基于人工神经网络的同步定位与映射模型的改进
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p3
Musa A. Hameed
{"title":"An Enhancement of Simultaneous Localization and Mapping Model Using Artificial Neural Networks","authors":"Musa A. Hameed","doi":"10.32441/kjps.02.02.p3","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p3","url":null,"abstract":"","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"46 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83955253","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Effect of Denture Cleansers on Color Stability, Water Sorption and Solubility of Stained Denture Base Materials 义齿洗洁剂对染色义齿基托材料颜色稳定性、吸水性和溶解度的影响
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p11
Mahabad Saleh, S. Salem
Background and Objectives: Denture cleanser is the most widely used method by the patients to maintain clean and healthy dentures but the prolonged use of such cleansers may affect the properties of the denture. The present study was carried out to evaluate the effect of three prepared denture cleansers which were the 4% citric acid, 4% tartaric acid, and 4% oxalic acid in addition to the Protefix a commercially available denture cleansers, on some mechanical and physical properties (color stability, water sorption, and solubility) of acrylic resin (Stellon QC-20) and flexible nylon (Vaplast) denture base materials after immersion in tea solution. Methods: One hundred specimens (100) were prepared in two equal major groups: acrylic resin and Valplast. For each test of the physical and mechanical properties, 50 specimens were prepared, 25 from acrylic resin and 25 from Valplast. Later on, divided into five groups, one group used as a control and immersed in distilled water, and remaining 4 groups used as test groups; by immersing in one of the denture cleansers after staining in tea solutions for 10 days. The effect of denture cleansers on the properties was studied and compared with the control group. Results: Visual examination method showed no color changes for acrylic and slight color change for valplast specimens. Valplast specimens showed higher water sorption and solubility than acrylic. Conclusions: The findings showed that the 4 denture cleansers were equally effective, and did not cause significant alteration in the tested properties. Except acrylic specimens immersed in oxalic acid showed less color stability.
背景与目的:义齿清洗剂是义齿患者最常用的保持义齿清洁健康的方法,但长期使用可能会影响义齿的性能。本研究在市售义齿清洁剂Protefix的基础上,研究了4%柠檬酸、4%酒石酸和4%草酸三种配制的义齿清洁剂对丙烯酸树脂(Stellon gc -20)和柔性尼龙(Vaplast)义齿基托材料在茶溶液中浸泡后的一些机械物理性能(颜色稳定性、吸水性和溶解度)的影响。方法:制备100例标本,分为丙烯酸树脂组和Valplast组。每次物理和机械性能测试,准备50个样品,25个来自丙烯酸树脂,25个来自Valplast。后分为5组,1组作为对照,浸泡在蒸馏水中,其余4组作为试验组;在茶叶溶液中染色后,将其中一种义齿清洁剂浸泡10天。研究了义齿清洗剂对义齿性能的影响,并与对照组进行了比较。结果:目测法亚克力标本无颜色变化,膜片标本有轻微颜色变化。Valplast样品的吸水性和溶解度均高于丙烯酸。结论:结果表明,4种义齿清洁剂的效果相同,并且没有引起测试性能的显着改变。除丙烯酸外,浸在草酸中的样品颜色稳定性较差。
{"title":"The Effect of Denture Cleansers on Color Stability, Water Sorption and Solubility of Stained Denture Base Materials","authors":"Mahabad Saleh, S. Salem","doi":"10.32441/kjps.02.02.p11","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p11","url":null,"abstract":"Background and Objectives: Denture cleanser is the most widely used method by the patients to maintain clean and healthy dentures but the prolonged use of such cleansers may affect the properties of the denture. The present study was carried out to evaluate the effect of three prepared denture cleansers which were the 4% citric acid, 4% tartaric acid, and 4% oxalic acid in addition to the Protefix a commercially available denture cleansers, on some mechanical and physical properties (color stability, water sorption, and solubility) of acrylic resin (Stellon QC-20) and flexible nylon (Vaplast) denture base materials after immersion in tea solution. Methods: One hundred specimens (100) were prepared in two equal major groups: acrylic resin and Valplast. For each test of the physical and mechanical properties, 50 specimens were prepared, 25 from acrylic resin and 25 from Valplast. Later on, divided into five groups, one group used as a control and immersed in distilled water, and remaining 4 groups used as test groups; by immersing in one of the denture cleansers after staining in tea solutions for 10 days. The effect of denture cleansers on the properties was studied and compared with the control group. Results: Visual examination method showed no color changes for acrylic and slight color change for valplast specimens. Valplast specimens showed higher water sorption and solubility than acrylic. Conclusions: The findings showed that the 4 denture cleansers were equally effective, and did not cause significant alteration in the tested properties. Except acrylic specimens immersed in oxalic acid showed less color stability.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88993350","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Efficient Performance Technical Selection of PositiveBuck-Boost Converter 正降压变换器的高效性能技术选择
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p2
A. Abbas, Abadal-Salam Hussain
The necessity for stable DC voltage in both removable and non-removable systems has been considerably desired recently. These systems have to be implemented efficiently in order to be responding rapidly based voltage variations. Under this act, the efficient power can extend the lifetime of the employed batteries in such systems. The presented efficiency can be realized with respect to buck and boost components that were implemented to generate what is called positive Buck-Boost converter circuits. The main functions of the positive Buck-Boost converter are identified by announcing the unchanged situation of output voltage polarity and indicating the level of the voltage rationally between the input and the output. It is worth mention, the positive Buck-Boost converter circuit was simulated based Proteus software, and the hardware components were connected in reality. Finally, the microcontroller type that employed in the proposed system is PIC_16F877A, which realizes the input voltage sensitively to generate Pulse Width Modulation (PWM) signals in order to feed the employed MOSFET element.
在可移动和不可移动的系统中,稳定直流电压的必要性最近已经得到了相当大的期望。这些系统必须有效地实施,以便快速响应基于电压的变化。在此法案下,有效的电力可以延长在这种系统中使用的电池的寿命。所提出的效率可以通过降压和升压元件来实现,这些元件被实现以产生所谓的正降压-升压转换器电路。正极Buck-Boost变换器的主要功能是通过显示输出电压极性的变化情况和合理指示输入输出之间的电压水平来识别。值得一提的是,基于Proteus软件对正降压变换器电路进行了仿真,并在实际中对硬件元件进行了连接。最后,本系统采用PIC_16F877A单片机类型,实现了输入电压灵敏地产生脉宽调制(PWM)信号,以馈送所采用的MOSFET元件。
{"title":"Efficient Performance Technical Selection of Positive\u0000Buck-Boost Converter","authors":"A. Abbas, Abadal-Salam Hussain","doi":"10.32441/kjps.02.02.p2","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p2","url":null,"abstract":"The necessity for stable DC voltage in both removable and non-removable systems has been considerably desired recently. These systems have to be implemented efficiently in order to be responding rapidly based voltage variations. Under this act, the efficient power can extend the lifetime of the employed batteries in such systems. The presented efficiency can be realized with respect to buck and boost components that were implemented to generate what is called positive Buck-Boost converter circuits. The main functions of the positive Buck-Boost converter are identified by announcing the unchanged situation of output voltage polarity and indicating the level of the voltage rationally between the input and the output. It is worth mention, the positive Buck-Boost converter circuit was simulated based Proteus software, and the hardware components were connected in reality. Finally, the microcontroller type that employed in the proposed system is PIC_16F877A, which realizes the input voltage sensitively to generate Pulse Width Modulation (PWM) signals in order to feed the employed MOSFET element.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"34 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81193006","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cenomanian-Early Campanian Carbonate ReservoirRocks of Northwestern Iraq: Diagenesis and PorosityDevelopment 伊拉克西北部塞诺曼—早坎帕世碳酸盐岩储层成岩作用与孔隙发育
Pub Date : 2018-12-30 DOI: 10.32441/kjps.02.02.p1
M. Al-Haj, A. Al‐Juboury, A. Al-hadidy, D. Hassan
The present work focuses on the upper Cretaceous (Cenomanian-early Campanian)carbonate successions in selected wells from northwestern Iraq. These successions arerepresented by Gir Bir (Cenomanian-early Turonian), Wajna (late Santonian) and Mushorah (early Campanian) Formations. The succession has affected by early burial near-surface, unconformity-related and deep burial diagenesis represented by cementation, neomorphism, dolomitization, dedolomitization, silicification, authigenesis of glauconite and pyrite, compaction, micritization, solution and porosity formation. The common porosity types are intergranular, fenestral, intercrystalline, moldic, vuggy, channel and fracture. Three porosity zones (I, II, and III) are identified depending on variation in gamma ray which reflects their shale content. The upper part of zone (II) is highly porous and regarded on the main reservoir unit in the middle and upper parts of the Gir Bir Formation. Fracture and moldic and vuggy dissolution features in addition to karstic and fissure features are responsible for the porosity increase in the fractured reservoir unit.
目前的工作重点是在伊拉克西北部选定的井中进行上白垩世(塞诺曼—早坎帕尼亚)碳酸盐岩演替。这些演替以吉尔比尔组(cenomanian - Turonian早期)、瓦伊纳组(Wajna)和穆索拉组(Mushorah)为代表。早期埋藏近地表成岩作用、不整合成岩作用和深埋藏成岩作用影响了演替过程,主要表现为胶结作用、新形作用、白云石化作用、脱白云石化作用、硅化作用、海绿石和黄铁矿自生作用、压实作用、泥晶化作用、溶蚀作用和孔隙形成作用。常见的孔隙类型有晶间、窗状、晶间、模状、洞状、槽状和裂缝状。根据反映页岩含量的伽马射线变化,确定了3个孔隙层(I、II和III)。(II)带上部孔隙度较高,是吉尔比尔组中上段的主要储层单元。裂缝性储层单元孔隙度增加的主要原因是裂缝、溶蚀、溶蚀特征和岩溶、裂隙特征。
{"title":"Cenomanian-Early Campanian Carbonate Reservoir\u0000Rocks of Northwestern Iraq: Diagenesis and Porosity\u0000Development","authors":"M. Al-Haj, A. Al‐Juboury, A. Al-hadidy, D. Hassan","doi":"10.32441/kjps.02.02.p1","DOIUrl":"https://doi.org/10.32441/kjps.02.02.p1","url":null,"abstract":"The present work focuses on the upper Cretaceous (Cenomanian-early Campanian)\u0000carbonate successions in selected wells from northwestern Iraq. These successions are\u0000represented by Gir Bir (Cenomanian-early Turonian), Wajna (late Santonian) and Mushorah (early Campanian) Formations. The succession has affected by early burial near-surface, unconformity-related and deep burial diagenesis represented by cementation, neomorphism, dolomitization, dedolomitization, silicification, authigenesis of glauconite and pyrite, compaction, micritization, solution and porosity formation. The common porosity types are intergranular, fenestral, intercrystalline, moldic, vuggy, channel and fracture. Three porosity zones (I, II, and III) are identified depending on variation in gamma ray which reflects their shale content. The upper part of zone (II) is highly porous and regarded on the main reservoir unit in the middle and upper parts of the Gir Bir Formation. Fracture and moldic and vuggy dissolution features in addition to karstic and fissure features are responsible for the porosity increase in the fractured reservoir unit.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84785198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Modified Method for Minimizing Current Distortion of A Single Phase Bridge Rectifier Based on Current Injection 基于电流注入的减小单相桥式整流器电流畸变的改进方法
Pub Date : 2018-10-10 DOI: 10.32441/KJPS.V2I1.141
Aasef Saleh Al-hyali, Hussien Zynal, A. Mahmood
Single phase bridge controlled rectifier, nonlinear load,, produces harmonics that effects on power quality of the AC power system. These distortions cause different problems that need to be solved. Therefore, reducing harmonics is very important issue. In this paper, line injection technique is used to reduce harmonics on the ac side of the single-phase bridge controlled and uncontrolled rectifier. This method depending on injecting harmonic components of the dc converter current with an opposite phase to its ac side lines at a particular frequency to get sinusoidal wave as possible and improving the power factor. Two injection circuits are used. The simulation results of the modified suggested circuits have been compared in order to show the advantages and disadvantages of each type. Parameters of the injection circuits are chosen depending on derived mathematical equations. The system is modeled implemented by  Matlab/Simulink. Simulation results show that THD of the AC current reduced about 81% with power factor around unity.
单相桥控整流器是一种非线性负载,其产生的谐波影响着交流电力系统的电能质量。这些扭曲造成了需要解决的不同问题。因此,减少谐波是一个非常重要的问题。本文采用线路注入技术来降低单相桥式可控和非可控整流器交流侧的谐波。该方法通过在直流变换器的交流边线上注入与直流变换器电流相反的谐波分量,在一定频率下尽可能得到正弦波,从而提高功率因数。使用两个注射回路。对改进电路的仿真结果进行了比较,以显示每种电路的优缺点。根据推导出的数学方程选择注射回路的参数。通过Matlab/Simulink对系统进行了建模实现。仿真结果表明,当功率因数在1左右时,交流电流的THD降低了约81%。
{"title":"Modified Method for Minimizing Current Distortion of A Single Phase Bridge Rectifier Based on Current Injection","authors":"Aasef Saleh Al-hyali, Hussien Zynal, A. Mahmood","doi":"10.32441/KJPS.V2I1.141","DOIUrl":"https://doi.org/10.32441/KJPS.V2I1.141","url":null,"abstract":"Single phase bridge controlled rectifier, nonlinear load,, produces harmonics that effects on power quality of the AC power system. These distortions cause different problems that need to be solved. Therefore, reducing harmonics is very important issue. In this paper, line injection technique is used to reduce harmonics on the ac side of the single-phase bridge controlled and uncontrolled rectifier. This method depending on injecting harmonic components of the dc converter current with an opposite phase to its ac side lines at a particular frequency to get sinusoidal wave as possible and improving the power factor. Two injection circuits are used. The simulation results of the modified suggested circuits have been compared in order to show the advantages and disadvantages of each type. Parameters of the injection circuits are chosen depending on derived mathematical equations. The system is modeled implemented by  Matlab/Simulink. Simulation results show that THD of the AC current reduced about 81% with power factor around unity.","PeriodicalId":7451,"journal":{"name":"Al-Kitab Journal for Pure Sciences","volume":"36 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75254034","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Al-Kitab Journal for Pure Sciences
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1