[Examination of the injured spleen using computer tomography]. [用计算机断层扫描检查损伤的脾脏]。
Pub Date : 1989-08-01
A Srp, J Bruna, L Halman, F Vyhnánek

In blunt abdominal injury the most frequently injured organ is the spleen. A rapid and precise diagnosis of an injured spleen is therefore of great importance for early and correct therapeutic procedure. The authors present a group of 56 patients, who have been examined in the 1981-1987 years after blunt injuries of the belly by computer tomography. In 12 cases there was the diagnosis of subcapsular haematoma of the spleen, intraparenchymatous rupture was present in eight patients. In the remaining 36 cases the trauma of abdominal organs was not confirmed. All findings were verified by surgery or a control computer tomography and clinical examination of the patients. The authors demonstrate typical traumatic conditions. Computer tomography is a very useful method which enables a rapid, precise and non-invasive diagnosis of different degree of the spleen injury, its possible complications and differentiates these conditions from uninjured spleen. The authors present a brief survey of pictures of injured spleen in other methods of examination. In comparison with those methods, computer tomography is the most effective one, which provides a complex information of other organs of abdominal cavity. It also enables a considerate examination of patients severely injured and in non-cooperating ones.

在钝性腹部损伤中,最常受伤的器官是脾脏。因此,快速准确地诊断脾脏损伤对于早期和正确的治疗程序非常重要。作者介绍了一组56例腹部钝性损伤患者,他们在1981-1987年间通过计算机断层扫描进行了检查。在12例诊断为脾包膜下血肿的病例中,有8例出现脾实质内破裂。其余36例腹部脏器损伤未确诊。所有发现均通过手术或对照计算机断层扫描和患者的临床检查得到证实。作者展示了典型的创伤状况。计算机断层扫描是一种非常有用的方法,可以快速、准确和无创地诊断不同程度的脾脏损伤及其可能的并发症,并将这些情况与未损伤的脾脏区分开来。作者简要介绍了其他检查方法中损伤脾的图片。与这些方法相比,计算机断层扫描是最有效的方法,它提供了腹腔其他器官的复杂信息。它还可以对严重受伤的病人和不合作的病人进行周到的检查。
{"title":"[Examination of the injured spleen using computer tomography].","authors":"A Srp,&nbsp;J Bruna,&nbsp;L Halman,&nbsp;F Vyhnánek","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In blunt abdominal injury the most frequently injured organ is the spleen. A rapid and precise diagnosis of an injured spleen is therefore of great importance for early and correct therapeutic procedure. The authors present a group of 56 patients, who have been examined in the 1981-1987 years after blunt injuries of the belly by computer tomography. In 12 cases there was the diagnosis of subcapsular haematoma of the spleen, intraparenchymatous rupture was present in eight patients. In the remaining 36 cases the trauma of abdominal organs was not confirmed. All findings were verified by surgery or a control computer tomography and clinical examination of the patients. The authors demonstrate typical traumatic conditions. Computer tomography is a very useful method which enables a rapid, precise and non-invasive diagnosis of different degree of the spleen injury, its possible complications and differentiates these conditions from uninjured spleen. The authors present a brief survey of pictures of injured spleen in other methods of examination. In comparison with those methods, computer tomography is the most effective one, which provides a complex information of other organs of abdominal cavity. It also enables a considerate examination of patients severely injured and in non-cooperating ones.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"230-6"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13930593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[A dynamic phantom for quality control of ventriculography examinations]. [用于脑室造影检查质量控制的动态幻像]。
Pub Date : 1989-08-01
J Erban, K Kleinbauer, V Husák, M Wiedermann

The authors designed and constructed device simulating the activity of the heart, based on periodic filling and emptying two rubber blowers a radioactive solution by means of two pistons in cylinders operated by two specially shaped cams. The phantom enables to control the correctness of the method and a computer programme for evaluating parameters of heart activity (ejection fraction, end-diastolic volume, pulse volume etc.) in balanced ventriculography performed by a scintillation camera coupled with a computer. The performed measurements have shown a very good agreement of the evaluated parameters with those set at the phantom. The designed device is of an original construction and was granted the author's certificate No. 238,298.

作者设计并制造了一种模拟心脏活动的装置,该装置是在两个特殊形状的凸轮操纵的气缸中的两个活塞周期性地向两个橡胶鼓风机中注入和排出放射性溶液的基础上实现的。幻影能够控制方法和计算机程序的正确性,以评估平衡心室造影中的心脏活动参数(射血分数,舒张末期容积,脉冲容积等),由闪烁相机与计算机耦合进行。所进行的测量表明,所评估的参数与在模型上设置的参数非常吻合。所设计的装置结构新颖,并获得了第238,298号作者证书。
{"title":"[A dynamic phantom for quality control of ventriculography examinations].","authors":"J Erban,&nbsp;K Kleinbauer,&nbsp;V Husák,&nbsp;M Wiedermann","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The authors designed and constructed device simulating the activity of the heart, based on periodic filling and emptying two rubber blowers a radioactive solution by means of two pistons in cylinders operated by two specially shaped cams. The phantom enables to control the correctness of the method and a computer programme for evaluating parameters of heart activity (ejection fraction, end-diastolic volume, pulse volume etc.) in balanced ventriculography performed by a scintillation camera coupled with a computer. The performed measurements have shown a very good agreement of the evaluated parameters with those set at the phantom. The designed device is of an original construction and was granted the author's certificate No. 238,298.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"250-7"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13930595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Melanoblastoma of the esophagus]. [食道黑色素母细胞瘤]。
Pub Date : 1989-08-01
L Bĕhal

The author presents an observation of a rare malignant melanoma of oesophagus, its radiographic picture being similar to sarcoma. The primary melanoblastoma may also affect other internal organs.

作者报告一罕见的食道恶性黑色素瘤,其影像学表现与肉瘤相似。原发性黑色素母细胞瘤也可能影响其他内脏器官。
{"title":"[Melanoblastoma of the esophagus].","authors":"L Bĕhal","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The author presents an observation of a rare malignant melanoma of oesophagus, its radiographic picture being similar to sarcoma. The primary melanoblastoma may also affect other internal organs.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"237-40"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13930594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Aortic aneurysm in Turner's syndrome]. [特纳综合征的主动脉瘤]。
Pub Date : 1989-08-01
S Vĕsín, V Chudanová

In a 23 year old female patient, hospitalized at the internal ward for precollapse condition in tachyarrhythmia seizure with signs of the Turner's syndrome and a corresponding chromosomal finding, a radiographic examination of thorax revealed, beside a spine deformity with a marked scoliosis, a spindle-like aneurysmatic dilatation of aortic arc. The duplication of its contour indicated suspected beginning dissection. The further course did not confirm it, though. The possibility of excluding atherosclerotic and luetic etiology of the aneurysm makes it possible to consider the Erdheim's cystic medionecrosis of aorta, which accompanies more frequently the Marfan's syndrome, whereas in the Turner's syndrome it has been reported exceptionally.

一例23岁女性患者,因快节奏性心律失常发作并伴有特纳综合征征象和相应的染色体发现而住院,胸部x线检查显示,除了脊柱畸形伴明显脊柱侧凸外,主动脉弓呈纺梭样动脉瘤状扩张。其轮廓的重复表明疑似开始解剖。然而,进一步的研究并没有证实这一点。排除动脉瘤的动脉粥样硬化和黄疸病因的可能性使得考虑Erdheim的囊性主动脉中坏死成为可能,它更常伴随马凡氏综合征,而在特纳综合征中有例外报道。
{"title":"[Aortic aneurysm in Turner's syndrome].","authors":"S Vĕsín,&nbsp;V Chudanová","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In a 23 year old female patient, hospitalized at the internal ward for precollapse condition in tachyarrhythmia seizure with signs of the Turner's syndrome and a corresponding chromosomal finding, a radiographic examination of thorax revealed, beside a spine deformity with a marked scoliosis, a spindle-like aneurysmatic dilatation of aortic arc. The duplication of its contour indicated suspected beginning dissection. The further course did not confirm it, though. The possibility of excluding atherosclerotic and luetic etiology of the aneurysm makes it possible to consider the Erdheim's cystic medionecrosis of aorta, which accompanies more frequently the Marfan's syndrome, whereas in the Turner's syndrome it has been reported exceptionally.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"226-9"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13930641","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Comparison of absorbed doses from cobalt irradiation sources]. [钴辐照源吸收剂量的比较]。
Pub Date : 1989-08-01
R Wagner, J Novotný, P Jirousek, I Kovár, I Horáková

A comparison of absorbed doses from medical cobalt beams was performed by means of thermoluminescent dosimeters at all radiotherapeutic workplaces in Czechoslovakia. At most workplaces (58%) the deviation from the reference primary etalon placed at the Institute of Radiation Dosimetry of the Czechoslovak Academy of Sciences was below 3%. Neither of the workplaces exhibited deviation higher than 5%, indicating a good level of clinical dosimetry.

在捷克斯洛伐克的所有放射治疗工作场所,利用热释光剂量计对医用钴束的吸收剂量进行了比较。在大多数工作场所(58%),与捷克斯洛伐克科学院辐射剂量学研究所的参考初级标准子的偏差低于3%。两个工作场所的偏差均不高于5%,表明临床剂量学水平良好。
{"title":"[Comparison of absorbed doses from cobalt irradiation sources].","authors":"R Wagner,&nbsp;J Novotný,&nbsp;P Jirousek,&nbsp;I Kovár,&nbsp;I Horáková","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A comparison of absorbed doses from medical cobalt beams was performed by means of thermoluminescent dosimeters at all radiotherapeutic workplaces in Czechoslovakia. At most workplaces (58%) the deviation from the reference primary etalon placed at the Institute of Radiation Dosimetry of the Czechoslovak Academy of Sciences was below 3%. Neither of the workplaces exhibited deviation higher than 5%, indicating a good level of clinical dosimetry.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"267-72"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13931115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Quality control of roentgenologic examinations]. x线检查的质量控制。
Pub Date : 1989-08-01
Z Chudácek
{"title":"[Quality control of roentgenologic examinations].","authors":"Z Chudácek","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 4","pages":"273-9"},"PeriodicalIF":0.0,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13931116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Variability of the ultrasonic picture in carcinoma of the breast]. [乳腺癌超声图像的变异性]。
Pub Date : 1989-05-01
L Vyhnánek, J Danes

The authors performed a retrospective analysis of ultrasonographic findings in 63 female patients with mammary cancer verified by histology. The ultrasonographic examination contributed significantly to the diagnostic results in 16.4% of patients. The ultrasonographic picture of mammary cancer was characteristically variable with the occurrence of various deviations, with prevailing main symptoms of cancer (irregularity of the shape in 81% and the contour in 100%, prevailing low and medium echoes in 97%, irregular distribution of internal echoes in 76.2%, retro-tumorous middle acoustic shade in 63.4%). The authors draw attention to the diagnostic role of individually marked deviations of echographic structure; the importance of careful examination of the formation in different planes in view of the tumour is pointed out, since the symptom of malignant process may be present in only one of them.

本文对63例经组织学证实的女性乳腺癌患者的超声表现进行回顾性分析。16.4%的患者超声检查对诊断结果有显著贡献。乳腺癌超声图像具有特征性变化,出现各种偏差,主要表现为肿瘤的主要症状(形状不规则占81%,轮廓不规则占100%,低、中回声占97%,内部回声分布不规则占76.2%,肿瘤后中声阴影占63.4%)。作者提请注意超声结构个别显著偏差的诊断作用;由于恶性过程的症状可能只出现在其中一个平面上,因此在肿瘤的不同平面上仔细检查形成的重要性被指出。
{"title":"[Variability of the ultrasonic picture in carcinoma of the breast].","authors":"L Vyhnánek,&nbsp;J Danes","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The authors performed a retrospective analysis of ultrasonographic findings in 63 female patients with mammary cancer verified by histology. The ultrasonographic examination contributed significantly to the diagnostic results in 16.4% of patients. The ultrasonographic picture of mammary cancer was characteristically variable with the occurrence of various deviations, with prevailing main symptoms of cancer (irregularity of the shape in 81% and the contour in 100%, prevailing low and medium echoes in 97%, irregular distribution of internal echoes in 76.2%, retro-tumorous middle acoustic shade in 63.4%). The authors draw attention to the diagnostic role of individually marked deviations of echographic structure; the importance of careful examination of the formation in different planes in view of the tumour is pointed out, since the symptom of malignant process may be present in only one of them.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 3","pages":"154-60"},"PeriodicalIF":0.0,"publicationDate":"1989-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13808563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Computer tomography and its use in orofacial oncology]. 计算机断层扫描及其在口腔面部肿瘤学中的应用。
Pub Date : 1989-05-01
L Perinka, J Mazánek, J Toman

The authors communicate their experience with the application of CT in the diagnosis of neoplasms in orofacial region. The examinations were done with the head CT apparatus of 2nd generation. Indications for this examination are defined in the following areas: 1) retromaxillary, 2) paranasal sinuses, 3) orbits, 4) parotid glands, 5) cranial base, 6) malformation diseases, 7) mandibular joint, 8) lower region of the face and neck, 9) cervical nodes, 10) tumours extensive in volume. The authors present an analysis of results of 63 examinations in 57 patients with tumorous diseases.

作者就CT在口面部肿瘤诊断中的应用经验进行了交流。采用第二代头部CT仪进行检查。这项检查的适应症定义在以下区域:1)上颌后,2)鼻窦,3)眼眶,4)腮腺,5)颅底,6)畸形疾病,7)下颌关节,8)面部和颈部下部,9)颈部淋巴结,10)体积广泛的肿瘤。本文对57例肿瘤患者的63项检查结果进行分析。
{"title":"[Computer tomography and its use in orofacial oncology].","authors":"L Perinka,&nbsp;J Mazánek,&nbsp;J Toman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The authors communicate their experience with the application of CT in the diagnosis of neoplasms in orofacial region. The examinations were done with the head CT apparatus of 2nd generation. Indications for this examination are defined in the following areas: 1) retromaxillary, 2) paranasal sinuses, 3) orbits, 4) parotid glands, 5) cranial base, 6) malformation diseases, 7) mandibular joint, 8) lower region of the face and neck, 9) cervical nodes, 10) tumours extensive in volume. The authors present an analysis of results of 63 examinations in 57 patients with tumorous diseases.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 3","pages":"166-72"},"PeriodicalIF":0.0,"publicationDate":"1989-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13897365","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Manual afterloading applicators for intracavitary brachytherapy]. [腔内近距离治疗的手动后加载涂抹器]。
Pub Date : 1989-05-01
T Tacev, V Krystof, J Dupák, B Kasták, O Rasovská, V Strnad

A technical description of uterovaginal and rectal applicator system of manual afterloading is described. A simple solution while using domestic materials covering the requirements of present-day brachytherapy. The applicators proved to be suitable for gamma radiation sources as well as for gamma-neutron radiation of 252Cf sources.

介绍了子宫阴道和直肠手动加药器系统的技术描述。一个简单的解决方案,同时使用国内材料涵盖当今近距离治疗的要求。应用证明适用于伽玛辐射源以及252Cf源的伽玛中子辐射。
{"title":"[Manual afterloading applicators for intracavitary brachytherapy].","authors":"T Tacev,&nbsp;V Krystof,&nbsp;J Dupák,&nbsp;B Kasták,&nbsp;O Rasovská,&nbsp;V Strnad","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A technical description of uterovaginal and rectal applicator system of manual afterloading is described. A simple solution while using domestic materials covering the requirements of present-day brachytherapy. The applicators proved to be suitable for gamma radiation sources as well as for gamma-neutron radiation of 252Cf sources.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 3","pages":"194-7"},"PeriodicalIF":0.0,"publicationDate":"1989-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13898612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Peroperative use of two-dimensional ultrasonic imaging in neurosurgery]. 二维超声成像在神经外科手术中的应用
Pub Date : 1989-05-01
M Santa, J Fagul'a, I Sulla, E Malinovský, I Santová

The use of "real-time" ultrasonographic two-dimensional picture in the neurosurgery operation theatre increases and improves the possibility of localization of intracerebral and intraspinal lesions, enables precise needle biopsies, decreases a potential risk of damage to healthy brain tissue, visualizes the results of tumour resection, helps in the localization of catheters into chambers and cysts. The final results of the application of two-dimensional picture in the course of neurosurgery operation is in speeding up the surgical therapy, giving it more precision and safety, while the prolongation of the operation due to the ultrasonography is negligible. The authors document the visualization possibilities of two-dimensional ultrasonographic scanning with linear probe in preoperational recordings of different types of lesions in intracranial and intraspinal space.

在神经外科手术室中使用“实时”超声二维图像增加并提高了脑内和椎管内病变定位的可能性,实现了精确的针活检,降低了对健康脑组织损伤的潜在风险,使肿瘤切除的结果可视化,有助于导管进入腔室和囊肿的定位。二维图像在神经外科手术过程中应用的最终结果是加快了手术治疗,使其更加精确和安全,而超声检查对手术的延长可以忽略不计。作者记录了线性探头二维超声扫描在术前记录颅内和椎管内不同类型病变的可能性。
{"title":"[Peroperative use of two-dimensional ultrasonic imaging in neurosurgery].","authors":"M Santa,&nbsp;J Fagul'a,&nbsp;I Sulla,&nbsp;E Malinovský,&nbsp;I Santová","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The use of \"real-time\" ultrasonographic two-dimensional picture in the neurosurgery operation theatre increases and improves the possibility of localization of intracerebral and intraspinal lesions, enables precise needle biopsies, decreases a potential risk of damage to healthy brain tissue, visualizes the results of tumour resection, helps in the localization of catheters into chambers and cysts. The final results of the application of two-dimensional picture in the course of neurosurgery operation is in speeding up the surgical therapy, giving it more precision and safety, while the prolongation of the operation due to the ultrasonography is negligible. The authors document the visualization possibilities of two-dimensional ultrasonographic scanning with linear probe in preoperational recordings of different types of lesions in intracranial and intraspinal space.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 3","pages":"146-53"},"PeriodicalIF":0.0,"publicationDate":"1989-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13808647","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Ceskoslovenska radiologie
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1