首页 > 最新文献

INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference最新文献

英文 中文
DC Power Plant Monitor Configuration and Acceptance Testing 直流电厂监控器配置及验收试验
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251594
T.B. Bailey
The issue to be discussed in this paper is how to configure the monitoring system in a DC power plant to deliver what is most beneficial to the user. As monitoring systems get more complex and offer more functionality, there is often confusion within the user community about what is necessary and useful. All too often these sophisticated systems are not used to a fraction of their capabilities. The thrust of this paper is to explore the various features of modern monitoring systems and the benefits they offer to the user. Today, DC power plants are often installed by third party installation vendors. When there are no specifics given in the scope of work, the installation vendor does precisely what he was contracted to do, install the monitor, not configure it. This paper will conclude with suggestions on how to define specific configuration parameters to be included in the scope of work
本文讨论的问题是如何配置直流发电厂的监控系统,以提供最有利于用户的服务。随着监控系统变得越来越复杂,提供的功能也越来越多,用户群体经常会对哪些是必要的和有用的感到困惑。通常情况下,这些复杂的系统不习惯它们的一小部分功能。本文的主旨是探讨现代监控系统的各种特点及其为用户提供的好处。今天,直流发电厂通常由第三方安装供应商安装。当工作范围中没有给出详细说明时,安装供应商将准确地按照合同要求进行操作,安装监视器,而不是配置它。本文最后将给出关于如何定义工作范围中包含的特定配置参数的建议
{"title":"DC Power Plant Monitor Configuration and Acceptance Testing","authors":"T.B. Bailey","doi":"10.1109/INTLEC.2006.251594","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251594","url":null,"abstract":"The issue to be discussed in this paper is how to configure the monitoring system in a DC power plant to deliver what is most beneficial to the user. As monitoring systems get more complex and offer more functionality, there is often confusion within the user community about what is necessary and useful. All too often these sophisticated systems are not used to a fraction of their capabilities. The thrust of this paper is to explore the various features of modern monitoring systems and the benefits they offer to the user. Today, DC power plants are often installed by third party installation vendors. When there are no specifics given in the scope of work, the installation vendor does precisely what he was contracted to do, install the monitor, not configure it. This paper will conclude with suggestions on how to define specific configuration parameters to be included in the scope of work","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"121 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129772613","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Dual-loop Digital Controller for Switching DC-DC converters 用于切换DC-DC转换器的双环数字控制器
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251652
Meng Shi, J. Sun, P. Enjeti
This paper presents a dual-loop digital control approach for switching DC-DC converters. With an additional nonlinear control loop, the effect of inherent time delay of linear digital control loop on load transient response can be eliminated. Load transient response can be improved with reduced overshoot, undershoot and settling time. Simulation results based on a synchronous buck converter are shown to validate the proposed dual-loop digital control approach
本文提出了一种用于DC-DC变换器开关的双环数字控制方法。通过增加非线性控制环,可以消除线性数字控制环固有时滞对负载暂态响应的影响。减小过调量、欠调量和稳定时间可以改善负载的瞬态响应。基于同步降压变换器的仿真结果验证了所提出的双环数字控制方法
{"title":"A Dual-loop Digital Controller for Switching DC-DC converters","authors":"Meng Shi, J. Sun, P. Enjeti","doi":"10.1109/INTLEC.2006.251652","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251652","url":null,"abstract":"This paper presents a dual-loop digital control approach for switching DC-DC converters. With an additional nonlinear control loop, the effect of inherent time delay of linear digital control loop on load transient response can be eliminated. Load transient response can be improved with reduced overshoot, undershoot and settling time. Simulation results based on a synchronous buck converter are shown to validate the proposed dual-loop digital control approach","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128661654","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Residual Capacity Estimation of Stationary Lithium-ion Secondary Cells in Telecommunications Systems Using a Brief Discharge 电信系统中使用短暂放电的固定锂离子二次电池剩余容量估计
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251640
T. Matsushima, T. Horie
Lithium-ion batteries are expected to contribute to miniaturizing power systems and prolonging backup times in telecommunications systems. From the viewpoint of maintenance, checking battery conditions automatically is desirable after the deployment of lithium-ion batteries to telecommunications systems. Estimating the residual capacity of backup batteries is one of our major concerns in maintaining them. To do this, we propose discharging lithium-ion batteries to an actual load for a short duration, measuring the voltages in this discharge, and estimating the capacity using the correlations between the voltages and residual capacities. We studied the fundamental correlations between the voltages during discharge and the residual capacities using trickle-charged single cells and a float-charged 14-cell series-connected battery in high-temperature acceleration tests. We found good correlations between the voltages and residual capacities in both the single cells and the battery. These correlations may be useful for estimating the residual capacities of float-charged lithium-ion batteries using brief discharges into actual loads
锂离子电池有望为电力系统的小型化和延长电信系统的备用时间做出贡献。从维护的角度来看,锂离子电池部署到电信系统后,自动检查电池状态是可取的。估计备用电池的剩余容量是我们维护备用电池的主要问题之一。为此,我们建议将锂离子电池短时间放电到实际负载上,测量放电中的电压,并使用电压和剩余容量之间的相关性来估计容量。在高温加速试验中,采用单节滴充和14节浮充串联蓄电池,研究了放电电压与剩余容量之间的基本关系。我们发现单个电池和电池的电压和剩余容量之间存在良好的相关性。这些相关性可能有助于估算浮式充电锂离子电池使用短暂放电到实际负载时的剩余容量
{"title":"Residual Capacity Estimation of Stationary Lithium-ion Secondary Cells in Telecommunications Systems Using a Brief Discharge","authors":"T. Matsushima, T. Horie","doi":"10.1109/INTLEC.2006.251640","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251640","url":null,"abstract":"Lithium-ion batteries are expected to contribute to miniaturizing power systems and prolonging backup times in telecommunications systems. From the viewpoint of maintenance, checking battery conditions automatically is desirable after the deployment of lithium-ion batteries to telecommunications systems. Estimating the residual capacity of backup batteries is one of our major concerns in maintaining them. To do this, we propose discharging lithium-ion batteries to an actual load for a short duration, measuring the voltages in this discharge, and estimating the capacity using the correlations between the voltages and residual capacities. We studied the fundamental correlations between the voltages during discharge and the residual capacities using trickle-charged single cells and a float-charged 14-cell series-connected battery in high-temperature acceleration tests. We found good correlations between the voltages and residual capacities in both the single cells and the battery. These correlations may be useful for estimating the residual capacities of float-charged lithium-ion batteries using brief discharges into actual loads","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130067774","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
UltraTM Capacitors for Short Duration Backup of DSL Cabinets DSL机柜短时间备份用超电容
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251616
C. Ashton
Telephone companies have traditionally provided a minimum of 8 hours of battery backup at remote locations served by portable engine-alternators. In many areas, this is mandated by state law or other regulatory rules. For lifeline telephony service and 911 availability, this backup is critical. However, in the brave new world of data and video services, a TV signal is not critical for someone suffering from a heart attack. Cable TV and telephone companies provide different levels of battery backup (from none to a few hours) for data and video services. Rather than be driven by regulatory minimums, the backup is driven more by the market (the demands [real or perceived] and needs of the consumers). The closer the electronic equipment moves to the residential customer, the less important backup power becomes for video and data services (excluding plain old telephone service that may be derived from the same broadband pipe), since few residences have their own UPS systems to keep their TVs and computers working during commercial AC power outages. For example, in a fiber-to-the-home (FTTH) application, where the electronics are at the house, if the electronics lose power, it is highly likely the whole house (including the TV and the computer) has lost power. Qwest has pursued a policy of little to no battery backup for FTTC and FTTN video/data only architectures for the past 9 years. Equipment problems more than customer complaints have caused us to recently re-evaluate that decision and look to put in minimal backup. -48 VDC lead-acid and Li-ion battery systems have been evaluated, as well as traditional UPS systems, and supertrade or ultratrade capacitors. Tests have shown that over the expected lifetime of the field electronics, the capacitors may prove to be the most costly and reliable alternative for backup times of less than 1 minute. This paper will explore the equipment related problems associated with having no battery backup, and evaluate the performance, as well as initial and maintenance costs of both battery and capacitor solutions. The proper amount of backup time required will also be discussed in relation to average outage frequency and duration on the U.S. grid
传统上,电话公司在偏远地区提供至少8小时的备用电池,由便携式发动机交流发电机提供服务。在许多地区,这是由州法律或其他监管规则强制规定的。对于生命线电话服务和911可用性,此备份至关重要。然而,在数据和视频服务的美丽新世界里,电视信号对心脏病发作的人来说并不重要。有线电视和电话公司为数据和视频服务提供不同级别的电池备份(从没有到几个小时)。而不是由监管最低标准驱动,备份更多的是由市场驱动(需求(真实的或感知的)和消费者的需求)。电子设备离住宅用户越近,备用电源对视频和数据服务(不包括可能来自同一宽带管道的普通老式电话服务)的重要性就越低,因为很少有住宅拥有自己的UPS系统,以便在商业交流停电期间保持电视和电脑的正常工作。例如,在光纤到户(FTTH)应用中,电子设备在家里,如果电子设备断电,很可能整个房子(包括电视和电脑)都断电了。在过去的9年里,Qwest一直奉行FTTC和FTTN视频/数据架构很少甚至没有电池备份的政策。设备问题比客户投诉更严重,导致我们最近重新评估了这一决定,并希望投入最少的备份。-48直流铅酸和锂离子电池系统,以及传统的UPS系统,超级贸易或超级贸易电容器进行了评估。测试表明,在现场电子设备的预期寿命内,电容器可能被证明是最昂贵和最可靠的替代方案,备份时间少于1分钟。本文将探讨与没有备用电池相关的设备相关问题,并评估电池和电容器解决方案的性能,以及初始和维护成本。适当的备用时间也将根据美国电网的平均停电频率和持续时间进行讨论
{"title":"UltraTM Capacitors for Short Duration Backup of DSL Cabinets","authors":"C. Ashton","doi":"10.1109/INTLEC.2006.251616","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251616","url":null,"abstract":"Telephone companies have traditionally provided a minimum of 8 hours of battery backup at remote locations served by portable engine-alternators. In many areas, this is mandated by state law or other regulatory rules. For lifeline telephony service and 911 availability, this backup is critical. However, in the brave new world of data and video services, a TV signal is not critical for someone suffering from a heart attack. Cable TV and telephone companies provide different levels of battery backup (from none to a few hours) for data and video services. Rather than be driven by regulatory minimums, the backup is driven more by the market (the demands [real or perceived] and needs of the consumers). The closer the electronic equipment moves to the residential customer, the less important backup power becomes for video and data services (excluding plain old telephone service that may be derived from the same broadband pipe), since few residences have their own UPS systems to keep their TVs and computers working during commercial AC power outages. For example, in a fiber-to-the-home (FTTH) application, where the electronics are at the house, if the electronics lose power, it is highly likely the whole house (including the TV and the computer) has lost power. Qwest has pursued a policy of little to no battery backup for FTTC and FTTN video/data only architectures for the past 9 years. Equipment problems more than customer complaints have caused us to recently re-evaluate that decision and look to put in minimal backup. -48 VDC lead-acid and Li-ion battery systems have been evaluated, as well as traditional UPS systems, and supertrade or ultratrade capacitors. Tests have shown that over the expected lifetime of the field electronics, the capacitors may prove to be the most costly and reliable alternative for backup times of less than 1 minute. This paper will explore the equipment related problems associated with having no battery backup, and evaluate the performance, as well as initial and maintenance costs of both battery and capacitor solutions. The proper amount of backup time required will also be discussed in relation to average outage frequency and duration on the U.S. grid","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"50 23","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132060722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Dynamic Characteristics of Pulse Rate Control of a POL Converter POL变换器脉冲速率控制的动态特性
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251629
I. Nishikawa, M. Ueno, Y. Ishizuka, M. Matsuo, J. Saito
From the perspective of good point-of-load (POL) designs, a fast response for load-change and high power efficiency are important factors. Pulse width modulation (PWM) control is a common control method for POL. Although this control method is very simple and stable for POL, the response for sudden load change is not so fast because of its fixed frequency. However, pulse rate control (PRC) is well suited to such applications. The PRC control method and its features are described, and advantages of PRC are revealed with the some simulated and experimental results
从良好的负载点(POL)设计的角度来看,对负载变化的快速响应和高功率效率是重要因素。脉宽调制(PWM)控制是一种常用的POL控制方法。虽然这种控制方法对于POL来说非常简单和稳定,但由于其频率固定,对负载突然变化的响应不是那么快。然而,脉冲速率控制(PRC)非常适合这种应用。介绍了PRC控制方法及其特点,并通过仿真和实验结果揭示了PRC的优点
{"title":"Dynamic Characteristics of Pulse Rate Control of a POL Converter","authors":"I. Nishikawa, M. Ueno, Y. Ishizuka, M. Matsuo, J. Saito","doi":"10.1109/INTLEC.2006.251629","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251629","url":null,"abstract":"From the perspective of good point-of-load (POL) designs, a fast response for load-change and high power efficiency are important factors. Pulse width modulation (PWM) control is a common control method for POL. Although this control method is very simple and stable for POL, the response for sudden load change is not so fast because of its fixed frequency. However, pulse rate control (PRC) is well suited to such applications. The PRC control method and its features are described, and advantages of PRC are revealed with the some simulated and experimental results","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126742131","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A State Space Modeling Approach of a Single-Stage Three Level Resonant AC/DC Converter Operating in Discontinuous Conduction Mode 断续导通模式单级三电平谐振AC/DC变换器的状态空间建模方法
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251671
M. Agamy, P. Jain
This paper presents a state space modeling approach for a single stage three level resonant power factor correction converter operating with variable frequency pulse width modulation control in discontinuous conduction mode. Modeling is achieved using a combined averaging and multiple-frequency approach. The model gives good prediction of both the transient and steady state operations of the converter. The dynamics of the output filter can also be represented as well as the influence of parasitic parameters such as the capacitor equivalent series resistance (ESR). This method also allows the separation of both the frequency and duty cycle as the control variables. All state variables are broken down into their frequency components, including high and low frequency components (the high frequency components being in the order of the switching frequency and the low frequency components being in the order of power line frequency) and the amplitudes of the frequency components are used as the new state variables. As a result a model is obtained that has the switching frequency as well as the required duty ratio for the pulse-width-modulation as separated control input variables, which facilitates controller design. The developed model is verified on a 2.3 kW, 48 V, input voltage 90-265 Vrms
本文提出了一种在断续导通模式下工作的单级三电平谐振功率因数校正变换器的状态空间建模方法。建模是使用组合平均和多频率方法实现的。该模型能很好地预测变换器的暂态和稳态运行。输出滤波器的动态也可以表示,以及寄生参数,如电容等效串联电阻(ESR)的影响。这种方法也允许分离频率和占空比作为控制变量。将所有状态变量分解为其频率分量,包括高频分量和低频分量(高频分量按开关频率的顺序排列,低频分量按电源线频率的顺序排列),并将频率分量的幅值作为新的状态变量。从而得到一个以开关频率和脉宽调制所需占空比作为分离控制输入变量的模型,便于控制器设计。所开发的模型在2.3 kW, 48 V,输入电压90-265 Vrms上进行了验证
{"title":"A State Space Modeling Approach of a Single-Stage Three Level Resonant AC/DC Converter Operating in Discontinuous Conduction Mode","authors":"M. Agamy, P. Jain","doi":"10.1109/INTLEC.2006.251671","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251671","url":null,"abstract":"This paper presents a state space modeling approach for a single stage three level resonant power factor correction converter operating with variable frequency pulse width modulation control in discontinuous conduction mode. Modeling is achieved using a combined averaging and multiple-frequency approach. The model gives good prediction of both the transient and steady state operations of the converter. The dynamics of the output filter can also be represented as well as the influence of parasitic parameters such as the capacitor equivalent series resistance (ESR). This method also allows the separation of both the frequency and duty cycle as the control variables. All state variables are broken down into their frequency components, including high and low frequency components (the high frequency components being in the order of the switching frequency and the low frequency components being in the order of power line frequency) and the amplitudes of the frequency components are used as the new state variables. As a result a model is obtained that has the switching frequency as well as the required duty ratio for the pulse-width-modulation as separated control input variables, which facilitates controller design. The developed model is verified on a 2.3 kW, 48 V, input voltage 90-265 Vrms","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133245869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
An End-User's Guide to Selecting AC/DC Power Plant Architecture. Bulk vs. Distributive 最终用户选择交流/直流电厂架构指南。散装vs分配
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251612
M. R. Moore
With recent advancements in densely packed switchmode -48 VDC rectifier designs, a new era of battery technologies such as lithium ion (LI) and lithium metal polymer (LMP), the rising cost of copper, high cost of capital and the latest National Electrical Code (NEC2005), it's time again to revisit the distributive vs. bulk question. The intent of this paper is to assist an end-user in determining which DC power plant architecture to select when designing a telecommunication equipment room layout. This paper will take into account the majority of considerations to be addressed when selecting an AC/DC power plant Architecture. The models will be presented by one (1) bulk solution and three (3) distributive solutions
随着高密度开关模式-48 VDC整流器设计的最新进展,锂离子(LI)和锂金属聚合物(LMP)等电池技术的新时代,铜成本的上升,高成本的资本和最新的国家电气规范(NEC2005),是时候重新审视分布式与批量问题了。本文的目的是帮助终端用户在设计电信机房布局时确定选择哪种直流发电厂架构。本文将考虑到选择交流/直流电厂架构时要解决的大多数问题。这些模型将由一(1)个批量解决方案和三(3)个分布式解决方案提出
{"title":"An End-User's Guide to Selecting AC/DC Power Plant Architecture. Bulk vs. Distributive","authors":"M. R. Moore","doi":"10.1109/INTLEC.2006.251612","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251612","url":null,"abstract":"With recent advancements in densely packed switchmode -48 VDC rectifier designs, a new era of battery technologies such as lithium ion (LI) and lithium metal polymer (LMP), the rising cost of copper, high cost of capital and the latest National Electrical Code (NEC2005), it's time again to revisit the distributive vs. bulk question. The intent of this paper is to assist an end-user in determining which DC power plant architecture to select when designing a telecommunication equipment room layout. This paper will take into account the majority of considerations to be addressed when selecting an AC/DC power plant Architecture. The models will be presented by one (1) bulk solution and three (3) distributive solutions","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"88 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134504798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal Feedback Control of Switch-Mode Power Converters 开关电源变换器的最优反馈控制
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251664
M. E. Jacobs
A new controller-filter structure for a switch-mode power converter is described. The controller produces a minimum-time control signal for step changes in output voltage or in load current by partitioning the state-vector plane for the converter's output filter with a simple curve. A companion filter estimates the state vector of the power converter by modeling the response of the power converter to the control signal. The controller, abandoning the traditional approach of producing duty cycle using a sawtooth waveform with an adjustable threshold, avoids the performance limitations ordinarily encountered with a linear feedback approach
介绍了一种用于开关型电源变换器的新型控制器-滤波器结构。控制器通过用简单的曲线划分变换器输出滤波器的状态向量平面,为输出电压或负载电流的阶跃变化产生最小时间控制信号。伴随滤波器通过模拟功率变换器对控制信号的响应来估计功率变换器的状态向量。该控制器放弃了使用具有可调阈值的锯齿波形产生占空比的传统方法,避免了线性反馈方法通常遇到的性能限制
{"title":"Optimal Feedback Control of Switch-Mode Power Converters","authors":"M. E. Jacobs","doi":"10.1109/INTLEC.2006.251664","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251664","url":null,"abstract":"A new controller-filter structure for a switch-mode power converter is described. The controller produces a minimum-time control signal for step changes in output voltage or in load current by partitioning the state-vector plane for the converter's output filter with a simple curve. A companion filter estimates the state vector of the power converter by modeling the response of the power converter to the control signal. The controller, abandoning the traditional approach of producing duty cycle using a sawtooth waveform with an adjustable threshold, avoids the performance limitations ordinarily encountered with a linear feedback approach","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115386300","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design and Analysis of High Performance Control Strategy for UPS with Repetitive Control 具有重复控制的UPS高性能控制策略设计与分析
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251665
Min Chen, Wei Yao, Mingyong Li, Z. Qian, Xiaoming Yuan
This paper proposed a control strategy based on repetitive control and PI control strategy with double loop configuration. The insertion of the inner current loop relieves the burden of the stability requirement. The repetitive controller is added to conventional PI controller, which achieves zero steady-state error with good dynamic performance. Simulation and experimental results validated its performance
本文提出了一种基于重复控制和双环结构PI控制的控制策略。内电流环的插入减轻了稳定性要求的负担。在传统PI控制器的基础上增加了重复控制器,实现了零稳态误差和良好的动态性能。仿真和实验结果验证了其性能
{"title":"Design and Analysis of High Performance Control Strategy for UPS with Repetitive Control","authors":"Min Chen, Wei Yao, Mingyong Li, Z. Qian, Xiaoming Yuan","doi":"10.1109/INTLEC.2006.251665","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251665","url":null,"abstract":"This paper proposed a control strategy based on repetitive control and PI control strategy with double loop configuration. The insertion of the inner current loop relieves the burden of the stability requirement. The repetitive controller is added to conventional PI controller, which achieves zero steady-state error with good dynamic performance. Simulation and experimental results validated its performance","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128881684","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Metal Hydride Fuel Cells, A New and Practical Approach for Backup and Emergency Power Applications 金属氢化物燃料电池:备用和应急电源应用的一种新的实用方法
Pub Date : 2006-12-04 DOI: 10.1109/INTLEC.2006.251656
K. Fok
The tremendous growth of telecom services has resulted in an increased demand for backup power. Businesses and consumers are demanding continuous uptime and telecom companies must provide extended run time backup power on the order of hours and days. In addition, there is a growing need for power protection to cope with natural disasters and acts of terrorism. Conventional approaches using batteries have issues with life, footprint, maintenance, and weight. Similarly, diesel gensets have issues with startup, maintenance, noise, and emissions. As the backup power needs of telecom companies and their customers have grown, it has become evident that new backup power solutions need to be developed. Metal hydride fuel cells offer a fundamentally new approach to fuel cells that results in a practical, low cost technology with unique performance advantages, including intrinsic energy storage, instant start capability, good low temperature performance, and fuel "hot swap" capabilities. Metal hydride fuel cells use non-noble metal catalysts and can be manufactured using conventional processes similar to those used for manufacturing commercial batteries. This paper provides an overview of the current status and capabilities of metal hydride fuel cell technology, including performance, life, energy storage, and prototype hardware. The benefits of metal hydride fuel cells for uninterruptible power supply (UPS) and emergency power applications will also be detailed
电信服务的巨大增长导致对备用电源的需求增加。企业和消费者要求持续的正常运行时间,电信公司必须提供延长运行时间的备用电源,以小时和天为单位。此外,为了应对自然灾害和恐怖主义行为,越来越需要电力保护。使用电池的传统方法存在寿命、占地面积、维护和重量等问题。同样,柴油发电机组在启动、维护、噪音和排放方面也存在问题。随着电信公司及其客户对备用电源需求的增长,开发新的备用电源解决方案的需求日益明显。金属氢化物燃料电池为燃料电池提供了一种全新的方法,它是一种实用、低成本的技术,具有独特的性能优势,包括内在的能量存储、即时启动能力、良好的低温性能和燃料“热插拔”能力。金属氢化物燃料电池使用非贵金属催化剂,可以使用与制造商业电池类似的传统工艺制造。本文概述了金属氢化物燃料电池技术的现状和能力,包括性能、寿命、能量存储和原型硬件。本文还将详细介绍金属氢化物燃料电池在不间断电源(UPS)和应急电源应用中的优势
{"title":"Metal Hydride Fuel Cells, A New and Practical Approach for Backup and Emergency Power Applications","authors":"K. Fok","doi":"10.1109/INTLEC.2006.251656","DOIUrl":"https://doi.org/10.1109/INTLEC.2006.251656","url":null,"abstract":"The tremendous growth of telecom services has resulted in an increased demand for backup power. Businesses and consumers are demanding continuous uptime and telecom companies must provide extended run time backup power on the order of hours and days. In addition, there is a growing need for power protection to cope with natural disasters and acts of terrorism. Conventional approaches using batteries have issues with life, footprint, maintenance, and weight. Similarly, diesel gensets have issues with startup, maintenance, noise, and emissions. As the backup power needs of telecom companies and their customers have grown, it has become evident that new backup power solutions need to be developed. Metal hydride fuel cells offer a fundamentally new approach to fuel cells that results in a practical, low cost technology with unique performance advantages, including intrinsic energy storage, instant start capability, good low temperature performance, and fuel \"hot swap\" capabilities. Metal hydride fuel cells use non-noble metal catalysts and can be manufactured using conventional processes similar to those used for manufacturing commercial batteries. This paper provides an overview of the current status and capabilities of metal hydride fuel cell technology, including performance, life, energy storage, and prototype hardware. The benefits of metal hydride fuel cells for uninterruptible power supply (UPS) and emergency power applications will also be detailed","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121349747","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
期刊
INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×