智能电网与可再生能源(英文)最新文献

英文 中文
Performance Evaluation of Mode Transition Strategy for 3P4W Microgrid Utilizing SOAP-FLL and LMLS Filtering Approach 基于SOAP-FLL和lls滤波方法的3P4W微网模式转换策略性能评价
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715916
Farheen Chishti, Bhim Singh
This work focusses on the performance evaluation of a three phase four wire (3P4W) AC microgrid under mode transition. The changeover from utility integrated to standalone control is carried out using modified synchronous observer aided preprocessing based frequency locked loop filter (SOAPFLL). It effectively traces the grid and load angle utilized for synchronization purpose. The power generation units of wind and PV power are the renewable resources utilized to fulfill the critical load demand under grid outage mode. The battery associated with bidirectional DC-DC converter allows reduction in the battery capacity rating. In fact, effective load current fundamental constituent extraction is carried out using least mean logarithmic square (LMLS) algorithm. It reduces the effect of the non-linear load harmonics on the utility power quality. It also allows sensitive load operation at the point of common coupling (PCC). The microgrid is modelled in Matlab and the simulation result procured, depict the smooth mode transition from utility associated operating mode to utility outage mode and vice-versa. The harmonics appearing in the grid current are eliminated successfully while providing enhanced power quality of grid and voltage of PCC.
本文主要研究了模式转换下三相四线(3P4W)交流微电网的性能评估。利用改进的同步观测器辅助预处理的锁频环滤波器(SOAPFLL)实现了从集成到独立控制的转换。它有效地跟踪了用于同步目的的网格和负载角度。风电和光伏发电机组是在电网停运模式下用于满足临界负荷需求的可再生资源。与双向DC-DC转换器相关的电池允许降低电池容量额定值。实际上,有效负载电流的基本成分提取是使用最小平均对数平方算法进行的。它降低了非线性负荷谐波对电力质量的影响。它还允许在公共耦合点(PCC)敏感负载操作。在Matlab中对微电网进行了建模,并获得了仿真结果,描述了从公用事业关联运行模式到公用事业中断模式的平滑模式转换,反之亦然。成功地消除了电网电流中的谐波,提高了电网的电能质量和PCC的电压。
{"title":"Performance Evaluation of Mode Transition Strategy for 3P4W Microgrid Utilizing SOAP-FLL and LMLS Filtering Approach","authors":"Farheen Chishti, Bhim Singh","doi":"10.1109/PESGRE52268.2022.9715916","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715916","url":null,"abstract":"This work focusses on the performance evaluation of a three phase four wire (3P4W) AC microgrid under mode transition. The changeover from utility integrated to standalone control is carried out using modified synchronous observer aided preprocessing based frequency locked loop filter (SOAPFLL). It effectively traces the grid and load angle utilized for synchronization purpose. The power generation units of wind and PV power are the renewable resources utilized to fulfill the critical load demand under grid outage mode. The battery associated with bidirectional DC-DC converter allows reduction in the battery capacity rating. In fact, effective load current fundamental constituent extraction is carried out using least mean logarithmic square (LMLS) algorithm. It reduces the effect of the non-linear load harmonics on the utility power quality. It also allows sensitive load operation at the point of common coupling (PCC). The microgrid is modelled in Matlab and the simulation result procured, depict the smooth mode transition from utility associated operating mode to utility outage mode and vice-versa. The harmonics appearing in the grid current are eliminated successfully while providing enhanced power quality of grid and voltage of PCC.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87990495","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A computationally less expensive fault detection technique in VSC-HVDC system using wavelet decomposition and support vector machine classifier 基于小波分解和支持向量机分类器的VSC-HVDC故障检测技术
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715818
A. Joshi, Raeeza Khathoon, Devikrishna, Pv Angel Peter, V. Vinod
The VSC-based HVDC system has gained more popularity due to the advancement in the high power carrying capability of the semiconductor switches. Despite the numerous advantages, the protection scheme faces the challenge to isolate the internal fault within 5 to 6ms. Moreover, the algorithm also deactivates the relay, to operate during the disturbances and external fault. This paper proposes a protection scheme utilizing Discrete Wavelet Transform (DWT) and Support Vector Machine (SVM) classifier. Several types of faults are created on the HVDC transmission lines using PSCAD/EMTDC. The current and voltage signals of the HVDC line are obtained and decomposed using DWT to obtain the detailed coefficients up to the third level. Features obtained from the detailed coefficients are further used for the training of SVM for the detection and classification of the fault. Since the proposed approach uses only the information from one end, it does not rely on communication. To avoid the high computational burden of the Wavelet transform, the protection scheme is designed in such a way that, it performs the DWT, only if the disturbance persists for five consecutive samples.
由于半导体开关在大功率承载能力方面的进步,基于vsc的高压直流输电系统越来越受到人们的欢迎。尽管有许多优点,但该保护方案面临着在5 ~ 6ms内隔离内部故障的挑战。此外,该算法还使继电器失活,使其在受到干扰和外部故障时仍能正常工作。本文提出了一种基于离散小波变换(DWT)和支持向量机(SVM)分类器的保护方案。使用PSCAD/EMTDC的高压直流输电线路会产生几种类型的故障。对高压直流线路的电流和电压信号进行获取和DWT分解,得到三级以上的详细系数。从详细系数中获得的特征进一步用于SVM的训练,用于故障的检测和分类。由于所提出的方法只使用来自一端的信息,因此它不依赖于通信。为了避免小波变换的高计算负担,保护方案被设计成只有当干扰持续5个连续样本时才执行小波变换。
{"title":"A computationally less expensive fault detection technique in VSC-HVDC system using wavelet decomposition and support vector machine classifier","authors":"A. Joshi, Raeeza Khathoon, Devikrishna, Pv Angel Peter, V. Vinod","doi":"10.1109/PESGRE52268.2022.9715818","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715818","url":null,"abstract":"The VSC-based HVDC system has gained more popularity due to the advancement in the high power carrying capability of the semiconductor switches. Despite the numerous advantages, the protection scheme faces the challenge to isolate the internal fault within 5 to 6ms. Moreover, the algorithm also deactivates the relay, to operate during the disturbances and external fault. This paper proposes a protection scheme utilizing Discrete Wavelet Transform (DWT) and Support Vector Machine (SVM) classifier. Several types of faults are created on the HVDC transmission lines using PSCAD/EMTDC. The current and voltage signals of the HVDC line are obtained and decomposed using DWT to obtain the detailed coefficients up to the third level. Features obtained from the detailed coefficients are further used for the training of SVM for the detection and classification of the fault. Since the proposed approach uses only the information from one end, it does not rely on communication. To avoid the high computational burden of the Wavelet transform, the protection scheme is designed in such a way that, it performs the DWT, only if the disturbance persists for five consecutive samples.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88224931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Analytical Prediction of Static Flux-Linkage Characteristics of Switched Reluctance Machine 开关磁阻电机静态磁链特性的分析预测
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715844
Anupam Verma, S. S. Ahmad, G. Narayanan
This paper deals with the analytical prediction of static flux-linkage characteristics of switched reluctance (SR) machines at the aligned and unaligned rotor positions, which determine the torque output. Specifically, this paper proposes a novel flux-tube based approach to derive closed-form analytical expressions for the effective air-region permeance at the aligned and unaligned rotor positions in terms of machine dimensions. The proposed method does not require preliminary finite element analysis (FEA), and includes the effect of rotor pole height on the flux-linkage characteristics. The predictions by the proposed method for three different machines are compared with the results of FEA and of three existing analytical methods. The results of the proposed method are found to be accurate and comparable to those of FEA in all cases. The aligned and unaligned flux-linkage characteristics of a 10000-rpm, 5-kW SR machine, thus predicted, are verified through FEA and experiments. Correlation between machine characteristics and dimensions, combined with good accuracy and low computation time, make the proposed method a useful tool for design optimization.
本文研究了开关磁阻电机在对准和未对准转子位置的静态磁链特性的分析预测,这决定了转矩的输出。具体地说,本文提出了一种新的基于磁通管的方法,导出了转子对准和未对准位置的有效气区导流率随机械尺寸的封闭解析表达式。该方法不需要初步的有限元分析,并且考虑了转子极高度对磁链特性的影响。并将该方法对三种不同机械的预测结果与有限元分析和三种现有分析方法的结果进行了比较。在所有情况下,所提出的方法的结果都是准确的,并且与有限元分析的结果相当。通过有限元分析和实验验证了所预测的1万rpm、5 kw SR电机的对中和未对中磁链特性。该方法具有机械特性与尺寸之间的相关性,且精度高,计算时间短,是设计优化的有效工具。
{"title":"Analytical Prediction of Static Flux-Linkage Characteristics of Switched Reluctance Machine","authors":"Anupam Verma, S. S. Ahmad, G. Narayanan","doi":"10.1109/PESGRE52268.2022.9715844","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715844","url":null,"abstract":"This paper deals with the analytical prediction of static flux-linkage characteristics of switched reluctance (SR) machines at the aligned and unaligned rotor positions, which determine the torque output. Specifically, this paper proposes a novel flux-tube based approach to derive closed-form analytical expressions for the effective air-region permeance at the aligned and unaligned rotor positions in terms of machine dimensions. The proposed method does not require preliminary finite element analysis (FEA), and includes the effect of rotor pole height on the flux-linkage characteristics. The predictions by the proposed method for three different machines are compared with the results of FEA and of three existing analytical methods. The results of the proposed method are found to be accurate and comparable to those of FEA in all cases. The aligned and unaligned flux-linkage characteristics of a 10000-rpm, 5-kW SR machine, thus predicted, are verified through FEA and experiments. Correlation between machine characteristics and dimensions, combined with good accuracy and low computation time, make the proposed method a useful tool for design optimization.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86125388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Management of Energy Storage Dispatch in Unbalanced Distribution Networks using OpenDSS 基于OpenDSS的不平衡配电网储能调度管理
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715947
Tripti Gangwar, N. Padhy, P. Jena
The proliferation of renewable energy resources in an active distribution network leads to increased benefits such as low carbon emission, free energy, and certain challenges like voltage and frequency fluctuation, increase in uncertainty, bidirectional power flow, etc. The integration of energy storage is proposed to mitigate the challenges faced due to the increased penetration of renewable energy resources. Moreover, the integration of storage, in turn, requires optimal planning and energy management methods for efficient utilization of the integrated energy storage systems. The present work describes an energy management approach by utilizing distributed energy storage (DES) in an unbalanced distribution network. The distribution network and all its elements are modeled in open distribution system simulator (OpenDSS). MATLAB-COM interface is utilized to drive the OpenDSS and analyze results. Also, additional constraints to prevent early end-of-life of battery energy storage are modeled in MATLAB. The method is validated on a practical Indian distribution system of IIT Roorkee.
可再生能源在主动式配电网中的扩散带来了低碳排放、自由能源等效益的增加,同时也带来了电压和频率波动、不确定性增加、双向潮流等挑战。为了缓解可再生能源日益普及所带来的挑战,提出了储能一体化方案。此外,储能一体化反过来又需要优化规划和能源管理方法,以有效利用集成储能系统。本文描述了一种在不平衡配电网中利用分布式储能(DES)的能量管理方法。在开放式配电系统模拟器(open distribution system simulator, OpenDSS)中对配电网及其各组成部分进行了建模。利用MATLAB-COM接口驱动OpenDSS并对结果进行分析。此外,还在MATLAB中对防止电池储能寿命提前终止的附加约束进行了建模。该方法在印度理工学院鲁尔基的一个实际配电系统上得到了验证。
{"title":"Management of Energy Storage Dispatch in Unbalanced Distribution Networks using OpenDSS","authors":"Tripti Gangwar, N. Padhy, P. Jena","doi":"10.1109/PESGRE52268.2022.9715947","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715947","url":null,"abstract":"The proliferation of renewable energy resources in an active distribution network leads to increased benefits such as low carbon emission, free energy, and certain challenges like voltage and frequency fluctuation, increase in uncertainty, bidirectional power flow, etc. The integration of energy storage is proposed to mitigate the challenges faced due to the increased penetration of renewable energy resources. Moreover, the integration of storage, in turn, requires optimal planning and energy management methods for efficient utilization of the integrated energy storage systems. The present work describes an energy management approach by utilizing distributed energy storage (DES) in an unbalanced distribution network. The distribution network and all its elements are modeled in open distribution system simulator (OpenDSS). MATLAB-COM interface is utilized to drive the OpenDSS and analyze results. Also, additional constraints to prevent early end-of-life of battery energy storage are modeled in MATLAB. The method is validated on a practical Indian distribution system of IIT Roorkee.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83828484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Energy Performance Improvement in House Boat Tourism through Clean Energy Route Interfaced with Energy Efficient Power Conversion Techniques and Energy Storage 通过清洁能源路线与高效能源转换技术和储能相结合,提高船屋旅游的能源性能
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715868
Aneesh Rajendran, P. Jayan, A. Mohammed Ajlif, J. Daniel, Aby Joseph, Anoop Surendran
With its unique culture and tradition, tourism is distinguished and globally attractive sector of economy in the Kerala state. House boat tourism is the backbone of this sector. Luxurious and climate controlled suites combined with back water transport are the major attraction of these house boats. For both propulsion and indoor amenities, the hydrocarbon based fuels are a key energy resource. The continuous exploitation of fossil fuels, especially petrol and diesel through combustion route as a primary energy source have landed in major contribution of carbon footprints and water pollution. The impact of these activities to climate change will lead to a threat for aquatic life and sustainable tourism. Energy efficiency and renewable energy are the forward players to tackle these challenges. Dependence on reliable and quality power from grid is also a challenge for these house boats during docked as well as sailing conditions. A novel methodology to harvest clean and free renewable energy from roof top Solar Photo Voltaic (SPV) modules, store using suitable energy storage technology combined with energy efficient power distribution using Low Voltage Direct Current (LVDC) to feed energy optimally to the hotel loads is discussed. Pre and post implementation Energy performance and climate impact is evaluated through Energy performance analysis and the same is discussed.
凭借其独特的文化和传统,旅游业是喀拉拉邦杰出的、具有全球吸引力的经济部门。船屋旅游是这个行业的支柱。豪华和气候控制套房结合回水运输是这些船屋的主要吸引力。无论是推进装置还是室内设施,碳氢化合物燃料都是关键的能源。化石燃料,特别是汽油和柴油通过燃烧途径作为主要能源的不断开采,已经成为碳足迹和水污染的主要贡献者。这些活动对气候变化的影响将对水生生物和可持续旅游业构成威胁。能源效率和可再生能源是应对这些挑战的先行者。在停靠和航行条件下,对来自电网的可靠和高质量电力的依赖也是这些房屋船面临的挑战。讨论了一种从屋顶太阳能光伏(SPV)模块中获取清洁和免费可再生能源的新方法,使用合适的储能技术与使用低压直流(LVDC)的节能配电相结合,以最佳方式向酒店负载提供能源。通过能源绩效分析对实施前后的能源绩效和气候影响进行了评估,并对其进行了讨论。
{"title":"Energy Performance Improvement in House Boat Tourism through Clean Energy Route Interfaced with Energy Efficient Power Conversion Techniques and Energy Storage","authors":"Aneesh Rajendran, P. Jayan, A. Mohammed Ajlif, J. Daniel, Aby Joseph, Anoop Surendran","doi":"10.1109/PESGRE52268.2022.9715868","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715868","url":null,"abstract":"With its unique culture and tradition, tourism is distinguished and globally attractive sector of economy in the Kerala state. House boat tourism is the backbone of this sector. Luxurious and climate controlled suites combined with back water transport are the major attraction of these house boats. For both propulsion and indoor amenities, the hydrocarbon based fuels are a key energy resource. The continuous exploitation of fossil fuels, especially petrol and diesel through combustion route as a primary energy source have landed in major contribution of carbon footprints and water pollution. The impact of these activities to climate change will lead to a threat for aquatic life and sustainable tourism. Energy efficiency and renewable energy are the forward players to tackle these challenges. Dependence on reliable and quality power from grid is also a challenge for these house boats during docked as well as sailing conditions. A novel methodology to harvest clean and free renewable energy from roof top Solar Photo Voltaic (SPV) modules, store using suitable energy storage technology combined with energy efficient power distribution using Low Voltage Direct Current (LVDC) to feed energy optimally to the hotel loads is discussed. Pre and post implementation Energy performance and climate impact is evaluated through Energy performance analysis and the same is discussed.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83776625","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Reliability Centered Capacity Management in Deregulated Power Market 以可靠性为中心的电力市场容量管理
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715840
B. Talukdar, B. C. Deka, A. Goswami
The thrust toward deregulation and delicensing of the electric utility industry has brought significant transformation in modern power distribution systems. In vertically integrated power systems, the capacity reserve (CR) allocation is centrally managed to meet the system performance standards under any outage condition. However, due to deregulation and delicensing of power distribution, entry barriers for private players for creating competition in the power market are reduced, enabling consumers to purchase the CR directly from the preferred energy providers based on their reliability levels. In this paper, an attempt has been made to illustrate how capacity reserve management (CRM) in a deregulated environment is done based on customer’s reliability satisfaction. The well-being framework is applied to develop the reliability model of a bilateral power market. A new index, CRAI, has been introduced to measure the availability of CR and examine the risk of the system. The proposed concepts have been exemplified in Roy Billinton Test System (RBTS).
对电力公用事业行业放松管制和放权的推动给现代配电系统带来了重大变革。在垂直一体化电力系统中,容量储备(CR)的分配是集中管理的,以满足系统在任何停电情况下的性能标准。然而,由于对电力分配的放松管制和许可,私营企业在电力市场中创造竞争的进入壁垒降低了,使消费者能够根据其可靠性水平直接从首选能源供应商处购买CR。本文试图说明在解除管制的环境下,如何基于客户的可靠性满意度来进行容量储备管理(CRM)。应用幸福感框架建立了双边电力市场的可靠性模型。引入了一个新的指标,cri,来衡量CR的可用性并检查系统的风险。所提出的概念已在罗伊比林顿测试系统(RBTS)中得到例证。
{"title":"Reliability Centered Capacity Management in Deregulated Power Market","authors":"B. Talukdar, B. C. Deka, A. Goswami","doi":"10.1109/PESGRE52268.2022.9715840","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715840","url":null,"abstract":"The thrust toward deregulation and delicensing of the electric utility industry has brought significant transformation in modern power distribution systems. In vertically integrated power systems, the capacity reserve (CR) allocation is centrally managed to meet the system performance standards under any outage condition. However, due to deregulation and delicensing of power distribution, entry barriers for private players for creating competition in the power market are reduced, enabling consumers to purchase the CR directly from the preferred energy providers based on their reliability levels. In this paper, an attempt has been made to illustrate how capacity reserve management (CRM) in a deregulated environment is done based on customer’s reliability satisfaction. The well-being framework is applied to develop the reliability model of a bilateral power market. A new index, CRAI, has been introduced to measure the availability of CR and examine the risk of the system. The proposed concepts have been exemplified in Roy Billinton Test System (RBTS).","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83416283","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Evaluation of SiC based Two-Level Inverter With Passive EMI Filter Against Dual Two-Level Inverter Under PWM Schemes 基于无源EMI滤波器的SiC双电平逆变器与PWM方案下双电平逆变器的对比评价
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715750
T. J. Nistane, Manish Kumar, Kalaiselvi Jayaraman
The two-level (TL) inverter employs a passive EMI filter to mitigate conducted common-mode (CM) electromagnetic interference (EMI) issues such as CM current and shaft voltage. Whereas the topology of dual two-level (DTL) inverter is emerged with the provision of dedicated pulse width modulation (PWM) scheme to eliminate the CM voltage and thereby considers the reduction of CM emissions in the system. However, the effect of CM voltage elimination on the attenuation performance of high frequency CM noise (up to 30 MHz) and shaft voltage in DTL inverter fed induction motor is not clearly stated in literature. Thus, this paper presents the theoretical and experimental discussion on comparative evaluation between TL inverter system with passive EMI filter and the DTL inverter under PWM schemes such as CM voltage elimination (CMVE) PWM and remote state PWM (RSPWM) scheme. The comparative evaluation is carried out in terms of attenuation of conducted CM emissions in relevance to the component requirement for both the systems. The experimental verification of the reported work is carried out for a 3-$phi$, 1.1 kW IM driven in star configuration for TL inverter and open-end winding configuration for DTL inverter.
双电平(TL)逆变器采用无源EMI滤波器来减轻传导共模(CM)电磁干扰(EMI)问题,如CM电流和轴电压。而双双电平(DTL)逆变器的拓扑结构则是通过提供专用的脉宽调制(PWM)方案来消除CM电压,从而考虑减少系统中的CM发射。然而,CM电压消除对DTL逆变馈电动机高频CM噪声(高达30 MHz)和轴电压衰减性能的影响,文献中并没有明确的论述。因此,本文对无源EMI滤波器的TL逆变器系统与CM电压消除(CMVE) PWM和远程状态PWM (RSPWM)方案下的DTL逆变器进行了理论和实验上的比较评价。根据两个系统的组件要求,在传导CM排放的衰减方面进行了比较评估。对3-$ $phi$, 1.1 kW IM驱动的TL逆变器星形结构和DTL逆变器的开口绕组结构进行了实验验证。
{"title":"Comparative Evaluation of SiC based Two-Level Inverter With Passive EMI Filter Against Dual Two-Level Inverter Under PWM Schemes","authors":"T. J. Nistane, Manish Kumar, Kalaiselvi Jayaraman","doi":"10.1109/PESGRE52268.2022.9715750","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715750","url":null,"abstract":"The two-level (TL) inverter employs a passive EMI filter to mitigate conducted common-mode (CM) electromagnetic interference (EMI) issues such as CM current and shaft voltage. Whereas the topology of dual two-level (DTL) inverter is emerged with the provision of dedicated pulse width modulation (PWM) scheme to eliminate the CM voltage and thereby considers the reduction of CM emissions in the system. However, the effect of CM voltage elimination on the attenuation performance of high frequency CM noise (up to 30 MHz) and shaft voltage in DTL inverter fed induction motor is not clearly stated in literature. Thus, this paper presents the theoretical and experimental discussion on comparative evaluation between TL inverter system with passive EMI filter and the DTL inverter under PWM schemes such as CM voltage elimination (CMVE) PWM and remote state PWM (RSPWM) scheme. The comparative evaluation is carried out in terms of attenuation of conducted CM emissions in relevance to the component requirement for both the systems. The experimental verification of the reported work is carried out for a 3-$phi$, 1.1 kW IM driven in star configuration for TL inverter and open-end winding configuration for DTL inverter.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83480923","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Novel Protection Scheme for Low Voltage DC Microgrid Based on Localized Measurement of Transient Reactor Voltage 基于暂态电抗器电压局部测量的低压直流微电网保护新方案
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715743
Saurabh Sharma, M. Tripathy, Li Wang
Fault detection in DC microgrid offers new challenges to detect and isolate the faulted segment within few milliseconds due to high rate of rise of fault current, absence of zero crossing, frequency and information of phasors. For reliable and secure operation of DC microgrid, a new protection scheme based on change in transient reactor voltage at one end of the cable is proposed for fault detection during grid connected and islanded mode of operation. Whenever the magnitude of change in transient reactor voltage observed at one end of the cable exceeds pre-defined threshold limit, an internal fault is detected. The proposed scheme is investigated for different transient and fault conditions such as internal faults at different locations with different fault resistances, external faults, AC side faults, load variation, DG outage and generation uncertainties due to change in environmental conditions to further demonstrate the feasibility and robustness of the proposed protection scheme. The simulation results confirms that the proposed protection scheme is fast, accurate, capable of identifying internal faults and types of faults in DC microgrid.
直流微电网故障检测由于故障电流上升速度快、无过零、无频率、无相量信息等特点,对在几毫秒内检测和隔离故障段提出了新的挑战。为了保证直流微电网的安全可靠运行,提出了一种基于电缆一端暂态电抗器电压变化的故障检测方案,用于并网和孤岛运行时的故障检测。每当在电缆一端观察到的瞬态电抗器电压的变化幅度超过预定义的阈值限制时,就会检测到内部故障。针对不同故障电阻位置的内部故障、外部故障、交流侧故障、负载变化、DG停电和环境条件变化引起的发电不确定性等不同暂态和故障情况,进一步验证了所提保护方案的可行性和鲁棒性。仿真结果表明,该保护方案快速、准确,能够识别直流微电网内部故障和故障类型。
{"title":"A Novel Protection Scheme for Low Voltage DC Microgrid Based on Localized Measurement of Transient Reactor Voltage","authors":"Saurabh Sharma, M. Tripathy, Li Wang","doi":"10.1109/PESGRE52268.2022.9715743","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715743","url":null,"abstract":"Fault detection in DC microgrid offers new challenges to detect and isolate the faulted segment within few milliseconds due to high rate of rise of fault current, absence of zero crossing, frequency and information of phasors. For reliable and secure operation of DC microgrid, a new protection scheme based on change in transient reactor voltage at one end of the cable is proposed for fault detection during grid connected and islanded mode of operation. Whenever the magnitude of change in transient reactor voltage observed at one end of the cable exceeds pre-defined threshold limit, an internal fault is detected. The proposed scheme is investigated for different transient and fault conditions such as internal faults at different locations with different fault resistances, external faults, AC side faults, load variation, DG outage and generation uncertainties due to change in environmental conditions to further demonstrate the feasibility and robustness of the proposed protection scheme. The simulation results confirms that the proposed protection scheme is fast, accurate, capable of identifying internal faults and types of faults in DC microgrid.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84767659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
3ph qZSI Controller Design using PI for DC side and PR for AC side Controller including Droop Characteristic in standalone mode 3ph qZSI控制器设计采用PI为直流侧,PR为交流侧,包括独立模式下的下垂特性
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715796
Shwetank Agrawal, B. Tyagi, Vishal Kumar, P. Sharma
This paper presents the closed loop controller design of a quasi-z-source inverter (qZSI). The qZSI is used as a single-stage power converter and can operate in buck and boost mode operation. Hence qZSI is an economical solution for distributed generation and eliminates the need for two-stage power conversion. To obtain the quality output ac supply, the closed multi-loop control method is proposed in this paper. In proposed control method, the controls of the dc and ac sides are done separately. The proportional and resonant controllers are used in the ac side, whereas proportional and integral controllers are used in the dc side. Furthermore, to mimic the behavior of the synchronous generator, the droop control is used to generate the reference voltage for ac side of the controller. The MATLAB/Simulink models are used for testing and analysis purpose.
提出了一种准z源逆变器的闭环控制器设计。qZSI用作单级功率转换器,可以在降压和升压模式下工作。因此,qZSI是分布式发电的经济解决方案,消除了两级功率转换的需要。为了获得高质量的交流电源输出,本文提出了多闭环控制方法。在该控制方法中,直流侧和交流侧的控制是分开进行的。比例控制器和谐振控制器用于交流侧,而比例控制器和积分控制器用于直流侧。此外,为了模拟同步发电机的行为,使用下垂控制来产生控制器交流侧的参考电压。使用MATLAB/Simulink模型进行测试和分析。
{"title":"3ph qZSI Controller Design using PI for DC side and PR for AC side Controller including Droop Characteristic in standalone mode","authors":"Shwetank Agrawal, B. Tyagi, Vishal Kumar, P. Sharma","doi":"10.1109/PESGRE52268.2022.9715796","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715796","url":null,"abstract":"This paper presents the closed loop controller design of a quasi-z-source inverter (qZSI). The qZSI is used as a single-stage power converter and can operate in buck and boost mode operation. Hence qZSI is an economical solution for distributed generation and eliminates the need for two-stage power conversion. To obtain the quality output ac supply, the closed multi-loop control method is proposed in this paper. In proposed control method, the controls of the dc and ac sides are done separately. The proportional and resonant controllers are used in the ac side, whereas proportional and integral controllers are used in the dc side. Furthermore, to mimic the behavior of the synchronous generator, the droop control is used to generate the reference voltage for ac side of the controller. The MATLAB/Simulink models are used for testing and analysis purpose.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88729281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Simplified Functional Hybrid Operation Mode for Grid-Interactive Building Energy Management 网格-交互建筑能源管理的简化功能混合运行模式
Pub Date : 2022-01-02 DOI: 10.1109/PESGRE52268.2022.9715880
Raheem Ariwoola, S. Kamalasadan
This work presents a simplified hybrid operation mode that efficiently controls how passive residential building operates to simultaneously meet occupants’ thermal comforts and reduce its power demands. By function, the proposed mode maximizes the building’s use of passive energy strategies through natural ventilation to reduce cooling or heating loads from the Heating Ventilation and Air Conditioning (HVAC) system operation. Simulation studies were performed for three selected residential buildings in Pacific Northwest National Laboratory building stocks varying from mild, warm, and humid-continental climates. The annual simulation results established a minimal number of periods that cooling or heating was needed to supplement natural ventilation. The hybrid control operation established significant heating demand reduction during the winter simulation periods and a widely varied cooling demand savings during the summer across the evaluated climate locations. The operation mode shows a scalable potential for model predictive control functions and other extensive applications in advanced demand management and transactive operations.
这项工作提出了一种简化的混合运行模式,有效地控制被动式住宅建筑的运行方式,同时满足居住者的热舒适并减少其电力需求。在功能上,该模式最大限度地利用了被动能源策略,通过自然通风来减少采暖通风和空调(HVAC)系统运行的冷却或加热负荷。模拟研究在太平洋西北国家实验室的三个住宅建筑中进行,这些建筑包括温和气候、温暖气候和湿润大陆性气候。年度模拟结果确定了需要冷却或加热以补充自然通风的最小周期。混合控制操作在冬季模拟期间建立了显著的供暖需求减少,并在评估的气候地点的夏季建立了广泛不同的制冷需求节约。该操作模式显示了模型预测控制功能的可扩展潜力,以及在高级需求管理和交互操作中的其他广泛应用。
{"title":"A Simplified Functional Hybrid Operation Mode for Grid-Interactive Building Energy Management","authors":"Raheem Ariwoola, S. Kamalasadan","doi":"10.1109/PESGRE52268.2022.9715880","DOIUrl":"https://doi.org/10.1109/PESGRE52268.2022.9715880","url":null,"abstract":"This work presents a simplified hybrid operation mode that efficiently controls how passive residential building operates to simultaneously meet occupants’ thermal comforts and reduce its power demands. By function, the proposed mode maximizes the building’s use of passive energy strategies through natural ventilation to reduce cooling or heating loads from the Heating Ventilation and Air Conditioning (HVAC) system operation. Simulation studies were performed for three selected residential buildings in Pacific Northwest National Laboratory building stocks varying from mild, warm, and humid-continental climates. The annual simulation results established a minimal number of periods that cooling or heating was needed to supplement natural ventilation. The hybrid control operation established significant heating demand reduction during the winter simulation periods and a widely varied cooling demand savings during the summer across the evaluated climate locations. The operation mode shows a scalable potential for model predictive control functions and other extensive applications in advanced demand management and transactive operations.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91050388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
智能电网与可再生能源(英文)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1