首页 > 最新文献

Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society最新文献

英文 中文
Descriptive ability of three local left ventricle pump models 三种局部左心室泵模型的描述能力
A. Cappello, G. Avanzolini
Three viscoelastic models of the left-ventricular (LV) pumping function are proposed and compared with the classical elastance-resistance description starting from data measured on dogs: isovolumic pressure at a given preload together with a series of LV pressure and outflow curves with graded aortic occlusions. The comparison criterion takes into account descriptive ability, robustness of the estimates, and their physical interpretation. The analysis confirms the presence of both activation and deactivation phenomena. The dependence of stiffness and resistance on afterload agrees with known myocardial features and supports the local validity of the proposed models.<>
本文提出了左心室(LV)泵送功能的三种粘弹性模型,并与经典的弹性-阻力描述进行了比较,这些描述是从狗身上测量的数据开始的:给定预负荷下的等容压,以及一系列左心室压力和分级主动脉闭塞的流出曲线。比较标准考虑了描述能力、估计的稳健性和它们的物理解释。分析证实了活化和失活现象的存在。刚度和阻力对后载荷的依赖性与已知心肌特征一致,支持了所提模型的局部有效性。
{"title":"Descriptive ability of three local left ventricle pump models","authors":"A. Cappello, G. Avanzolini","doi":"10.1109/IEMBS.1988.94646","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94646","url":null,"abstract":"Three viscoelastic models of the left-ventricular (LV) pumping function are proposed and compared with the classical elastance-resistance description starting from data measured on dogs: isovolumic pressure at a given preload together with a series of LV pressure and outflow curves with graded aortic occlusions. The comparison criterion takes into account descriptive ability, robustness of the estimates, and their physical interpretation. The analysis confirms the presence of both activation and deactivation phenomena. The dependence of stiffness and resistance on afterload agrees with known myocardial features and supports the local validity of the proposed models.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117189116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Simulating neurons with SABER 用SABER模拟神经元
N. Carnevale, T. Woolf, G. M. Shepherd
Hypotheses of neuronal functions that invoke realistic anatomical and biophysical properties must be confirmed by quantitative simulation. Most simulators are unable to emulate biophysical phenomena such as time- and voltage-dependent (active) conductances directly. The authors report how special features of SABER, a new general-purpose simulator, facilitated the modeling of active conductances.<>
神经元功能的假设调用现实解剖和生物物理特性必须通过定量模拟来证实。大多数模拟器无法直接模拟生物物理现象,如时间和电压相关(有源)电导。作者报告了新型通用模拟器SABER的特殊功能如何促进有源电导的建模。
{"title":"Simulating neurons with SABER","authors":"N. Carnevale, T. Woolf, G. M. Shepherd","doi":"10.1109/IEMBS.1988.95353","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95353","url":null,"abstract":"Hypotheses of neuronal functions that invoke realistic anatomical and biophysical properties must be confirmed by quantitative simulation. Most simulators are unable to emulate biophysical phenomena such as time- and voltage-dependent (active) conductances directly. The authors report how special features of SABER, a new general-purpose simulator, facilitated the modeling of active conductances.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120972397","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Feedback control of blood pressure evaluations by a simple mechanical device 一种简单机械装置对血压评估的反馈控制
D. Sideris
Reducing the venous return in proportion to the blood pressure (BP) can prevent abnormal elevations of the latter. The possibility of applying this principle is examined for either permanent or acute control of a high BP. An implantable extravascular device based on this principle was applied in four dogs. One animal survived up to the 12th day and another was sacrificed in the 6th week. An external intravascular version was applied in four dogs. After setting the average BP to around 100 mm Hg, the device mitigated a metaraminol-induced BP elevation from about 240 to about 150 mm Hg without reducing BP when the hypertensive stimulus subsided.<>
减少静脉回流与血压(BP)成比例可以防止后者的异常升高。将这一原理应用于永久性或急性高血压控制的可能性进行了研究。基于这一原理的植入式血管外装置应用于四只狗。1只存活至第12天,另1只于第6周处死。在四只狗身上应用了外部血管内版本。在将平均血压设定为100毫米汞柱左右后,该装置将甲氨酚引起的血压升高从240毫米汞柱左右降低到150毫米汞柱左右,但在高血压刺激消退时没有降低血压。
{"title":"Feedback control of blood pressure evaluations by a simple mechanical device","authors":"D. Sideris","doi":"10.1109/IEMBS.1988.94634","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94634","url":null,"abstract":"Reducing the venous return in proportion to the blood pressure (BP) can prevent abnormal elevations of the latter. The possibility of applying this principle is examined for either permanent or acute control of a high BP. An implantable extravascular device based on this principle was applied in four dogs. One animal survived up to the 12th day and another was sacrificed in the 6th week. An external intravascular version was applied in four dogs. After setting the average BP to around 100 mm Hg, the device mitigated a metaraminol-induced BP elevation from about 240 to about 150 mm Hg without reducing BP when the hypertensive stimulus subsided.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120976757","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An in-vitro test system for electrochemical sensors 一种电化学传感器体外测试系统
J. Heller, W. McMahan, N. Bryan
A computer system has been developed to automate the in-vivo evaluation of amperometric electrochemical sensors in unanesthetized, tethered rabbits. Subcutaneous glucose, oxygen and temperature are monitored. Continuous, simultaneous monitoring of eight animals for several weeks is possible. Data collection rates are adjustable up to once every five minutes. Blood sample withdrawal and intravenous injection are carried out manually through a remote access port with computer prompting. Blood chemistry results are entered via keyboard and merged with the database from the sensor outputs. This multiple, parallel testing with minimal personnel intervention has made in-vivo statistical analysis of experimental electrochemical sensors feasible.<>
一种计算机系统已被开发用于在未麻醉的系留兔子体内自动评估安培电化学传感器。监测皮下葡萄糖、氧气和体温。对8只动物进行连续数周的同时监测是可能的。数据采集速率可调,最多5分钟一次。采集血样和静脉注射通过远程访问端口进行,并有计算机提示。血液化学结果通过键盘输入,并与传感器输出的数据库合并。这种以最少人员干预的多重并行测试使得实验电化学传感器的体内统计分析成为可能。
{"title":"An in-vitro test system for electrochemical sensors","authors":"J. Heller, W. McMahan, N. Bryan","doi":"10.1109/IEMBS.1988.95047","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95047","url":null,"abstract":"A computer system has been developed to automate the in-vivo evaluation of amperometric electrochemical sensors in unanesthetized, tethered rabbits. Subcutaneous glucose, oxygen and temperature are monitored. Continuous, simultaneous monitoring of eight animals for several weeks is possible. Data collection rates are adjustable up to once every five minutes. Blood sample withdrawal and intravenous injection are carried out manually through a remote access port with computer prompting. Blood chemistry results are entered via keyboard and merged with the database from the sensor outputs. This multiple, parallel testing with minimal personnel intervention has made in-vivo statistical analysis of experimental electrochemical sensors feasible.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121003604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Rule-based diagnostic decision aids for common eye problems 基于规则的诊断决策辅助常见眼病
S. Weiss, C. Dawson, I. Kapouleas, R. Nozik, D. Skorich, J. Ostroff
In developing countries, blindness often results from a lack of proper treatment for relatively simple eye problems. Specialist medical care is not readily available, and patients are seen by frontline health workers. To assist primary health workers in the management of common and potentially blinding eye disorders, the authors have developed a computer program for a hand-held computer that incorporates a set of guidelines for diagnosis and treatment or referral to a more distant medical center. They review the progress made in implementing, testing, and disseminating this program. They also describe progress in developing another program for automating laboratory test selection in uveitis.<>
在发展中国家,失明往往是由于对相对简单的眼睛问题缺乏适当的治疗。专科医疗服务并不容易获得,病人由一线卫生工作者诊治。为了帮助初级卫生工作者管理常见的和可能致盲的眼部疾病,作者开发了一个手持式计算机的计算机程序,该程序包含一套诊断和治疗指南或转诊到较远的医疗中心。他们审查了在实施、测试和传播该计划方面取得的进展。他们还描述了开发另一个自动选择葡萄膜炎实验室测试的程序的进展。
{"title":"Rule-based diagnostic decision aids for common eye problems","authors":"S. Weiss, C. Dawson, I. Kapouleas, R. Nozik, D. Skorich, J. Ostroff","doi":"10.1109/IEMBS.1988.95188","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95188","url":null,"abstract":"In developing countries, blindness often results from a lack of proper treatment for relatively simple eye problems. Specialist medical care is not readily available, and patients are seen by frontline health workers. To assist primary health workers in the management of common and potentially blinding eye disorders, the authors have developed a computer program for a hand-held computer that incorporates a set of guidelines for diagnosis and treatment or referral to a more distant medical center. They review the progress made in implementing, testing, and disseminating this program. They also describe progress in developing another program for automating laboratory test selection in uveitis.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121268359","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Realtime mandibular motion analysis-recent developments 实时下颌运动分析-最新进展
S. Curry, S. Baumrind
The authors have developed a real-time mandibular motion analysis system. A nonrestraining extraoral harness carries a set of light-emitting diodes (LEDs), whose movements are detected by photodiode detectors interfaced to a personal computer. Mandibular motions are computed rigorously in three dimensions. Movements at various points on the mandible are displayed on a graphics monitor. The system will find application in the characterization of temporo-mandibular joint (TMJ) disfunction and in the determination of changes in functional jaw movements after orthodontic treatment and orthognathic surgery. Recent developments have included an increase in accuracy, a hardware upgrade for greater data analysis speed, and the addition of a free-hand pointer for the identification of anatomic features of interest to the user.<>
作者开发了一个实时下颌运动分析系统。一种非限制性口外束带携带一组发光二极管(led),其运动由与个人计算机接口的光电二极管探测器检测。下颌运动是在三维严格计算。下颌骨各点的运动显示在图形监视器上。该系统将用于表征颞下颌关节(TMJ)功能障碍,并确定正畸治疗和正颌手术后功能性颌骨运动的变化。最近的发展包括准确性的提高,硬件升级以提高数据分析速度,以及增加一个徒手指针以识别用户感兴趣的解剖特征。
{"title":"Realtime mandibular motion analysis-recent developments","authors":"S. Curry, S. Baumrind","doi":"10.1109/IEMBS.1988.95204","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95204","url":null,"abstract":"The authors have developed a real-time mandibular motion analysis system. A nonrestraining extraoral harness carries a set of light-emitting diodes (LEDs), whose movements are detected by photodiode detectors interfaced to a personal computer. Mandibular motions are computed rigorously in three dimensions. Movements at various points on the mandible are displayed on a graphics monitor. The system will find application in the characterization of temporo-mandibular joint (TMJ) disfunction and in the determination of changes in functional jaw movements after orthodontic treatment and orthognathic surgery. Recent developments have included an increase in accuracy, a hardware upgrade for greater data analysis speed, and the addition of a free-hand pointer for the identification of anatomic features of interest to the user.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127106260","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Blood pressure measurement artifact rejection in noisy environments 噪声环境下血压测量伪影的抑制
C.T. Chittenden, C. S. Weaver
A novel ambulatory blood pressure monitor shows high accuracy even in the presence of an artifact. Signal processing algorithms separate true blood-pressure signals from noise induced by the environment or by subject motion. The algorithms adaptively utilize timing information obtained from ECG and Korotkov sound signals as well as Korotkov sound magnitude. A clinical study verified highly accurate results in an exercise stress testing environment. An independent study verified that the monitor produces highly accurate results in stress test and ambulatory environments.<>
一种新型的动态血压监测仪即使在人工制品存在的情况下也显示出很高的准确性。信号处理算法将真正的血压信号从环境或受试者运动引起的噪声中分离出来。该算法自适应地利用从心电和科罗特科夫声信号以及科罗特科夫声幅值中获得的时序信息。一项临床研究在运动压力测试环境中验证了高度准确的结果。一项独立研究证实,该监测仪在压力测试和流动环境中产生了高度准确的结果。
{"title":"Blood pressure measurement artifact rejection in noisy environments","authors":"C.T. Chittenden, C. S. Weaver","doi":"10.1109/IEMBS.1988.94414","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94414","url":null,"abstract":"A novel ambulatory blood pressure monitor shows high accuracy even in the presence of an artifact. Signal processing algorithms separate true blood-pressure signals from noise induced by the environment or by subject motion. The algorithms adaptively utilize timing information obtained from ECG and Korotkov sound signals as well as Korotkov sound magnitude. A clinical study verified highly accurate results in an exercise stress testing environment. An independent study verified that the monitor produces highly accurate results in stress test and ambulatory environments.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127133450","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Digital simulation of the burn patient shock-design of an optimum reanimation treatment 数字模拟烧伤患者休克-设计最佳的复苏治疗
L. Roa, T. Gómez-Cía, A. Cantero
The authors present a comparative study of the responses of burn patients to different reanimation treatments, one of them designed by experimental and clinical methods, and another one (BET) designed by digital simulation in a burn injury simulator. The alterations of the capillary dynamics and the therapeutics after the burn injury are analyzed with the mathematical model. The optimum treatment described in this report was superior in all trials. The authors conclude that BET can be used advantageously in burn patient shock stage in order to minimize complications.<>
本文比较研究了烧伤患者对不同复苏治疗方法的反应,其中一种是采用实验和临床方法设计的,另一种是采用烧伤模拟器数字模拟设计的。用数学模型分析了烧伤后毛细血管动力学的变化和治疗方法。本报告中所描述的最佳治疗在所有试验中都是优越的。作者认为,为了减少并发症,BET可以在烧伤患者休克阶段得到有利的应用
{"title":"Digital simulation of the burn patient shock-design of an optimum reanimation treatment","authors":"L. Roa, T. Gómez-Cía, A. Cantero","doi":"10.1109/IEMBS.1988.94687","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94687","url":null,"abstract":"The authors present a comparative study of the responses of burn patients to different reanimation treatments, one of them designed by experimental and clinical methods, and another one (BET) designed by digital simulation in a burn injury simulator. The alterations of the capillary dynamics and the therapeutics after the burn injury are analyzed with the mathematical model. The optimum treatment described in this report was superior in all trials. The authors conclude that BET can be used advantageously in burn patient shock stage in order to minimize complications.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127219594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Flow velocity measurements for pulsatile flow 脉动流的流速测量
D. Saloner
The inherent sensitivity of magnetic resonance imaging to motion makes it particularly well-suited as a noninvasive flow measurement modality. A pulse sequence which labels moving material by subjecting it to a pulse that inverts the longitudinal magnetization is discussed. Repeated application of this pulse produces a steady-state distribution of magnetization reflecting the history of material motion through the region of excitation. The sequence produces a strong suppression of signal from stationary material enhancing the dynamic range available to signal from moving material. In particular, angiographic-type projection images of flow in human subjects have been obtained with gated acquisition. These images display boli of tagged blood moving in arteries and veins. The boli are displaced in a direction and through a distance reflecting the temporal and spatial variation of velocity in the vessel.<>
磁共振成像对运动的固有敏感性使其特别适合作为一种非侵入性流量测量方式。讨论了一种脉冲序列,该脉冲序列通过使运动材料受到反向纵向磁化的脉冲来标记运动材料。这种脉冲的重复应用产生了一个稳态的磁化分布,反映了通过激励区域的物质运动的历史。该序列对来自静止材料的信号产生强烈的抑制,增强了来自移动材料的信号的动态范围。特别是,血管造影型投影图像的血流在人类受试者已获得与门控采集。这些图像显示了在动脉和静脉中流动的标记血液。波在一个方向上和通过一段距离的位移反映了容器中速度的时空变化。
{"title":"Flow velocity measurements for pulsatile flow","authors":"D. Saloner","doi":"10.1109/IEMBS.1988.94543","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94543","url":null,"abstract":"The inherent sensitivity of magnetic resonance imaging to motion makes it particularly well-suited as a noninvasive flow measurement modality. A pulse sequence which labels moving material by subjecting it to a pulse that inverts the longitudinal magnetization is discussed. Repeated application of this pulse produces a steady-state distribution of magnetization reflecting the history of material motion through the region of excitation. The sequence produces a strong suppression of signal from stationary material enhancing the dynamic range available to signal from moving material. In particular, angiographic-type projection images of flow in human subjects have been obtained with gated acquisition. These images display boli of tagged blood moving in arteries and veins. The boli are displaced in a direction and through a distance reflecting the temporal and spatial variation of velocity in the vessel.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124817595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Relation of defibrillatory potential minima to post-defibrillatory activation 除颤电位最小值与除颤后激活的关系
F. Witkowski, P. Penkoske
Management of patients with malignant arrhythmias occurring outside the hospital and the development of clinically applicable systems for internal defibrillation have stimulated interest in the factors influencing cardiac defibrillation. Using a directly coupled (DC) electrode and amplification scheme, the authors have developed a system capable of simultaneous three-dimensional mapping of both the high energy shock field created in the heart by defibrillation electrodes in addition to the mapping of the immediate postshock myocardial activation sequence. Experiments performed in vivo in anesthetized open-chest dogs revealed that successful defibrillation required 100% of the site examined to be depolarized, with the first post defibrillation beat originating in the area of minimum defibrillatory potential.<>
院外恶性心律失常患者的管理和临床适用的内部除颤系统的发展激发了对心脏除颤影响因素的兴趣。使用直接耦合(DC)电极和放大方案,作者开发了一种系统,该系统能够同时对除颤电极在心脏中产生的高能量冲击场进行三维映射,以及对休克后立即心肌激活序列进行映射。在麻醉开胸犬体内进行的实验显示,成功的除颤需要100%的检查部位去极化,除颤后的第一次心跳起源于最低除颤电位的区域。
{"title":"Relation of defibrillatory potential minima to post-defibrillatory activation","authors":"F. Witkowski, P. Penkoske","doi":"10.1109/IEMBS.1988.94483","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94483","url":null,"abstract":"Management of patients with malignant arrhythmias occurring outside the hospital and the development of clinically applicable systems for internal defibrillation have stimulated interest in the factors influencing cardiac defibrillation. Using a directly coupled (DC) electrode and amplification scheme, the authors have developed a system capable of simultaneous three-dimensional mapping of both the high energy shock field created in the heart by defibrillation electrodes in addition to the mapping of the immediate postshock myocardial activation sequence. Experiments performed in vivo in anesthetized open-chest dogs revealed that successful defibrillation required 100% of the site examined to be depolarized, with the first post defibrillation beat originating in the area of minimum defibrillatory potential.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125003248","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
期刊
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1